30 mm Push Buttons 9001K and SK Selector Switches

Size: px
Start display at page:

Download "30 mm Push Buttons 9001K and SK Selector Switches"

Transcription

1 30 mm Push Buttons 9001K and SK Selector Switches NOTE: To order, add prefix 9001 to the beginning of the catalog number. Table : 2-Position Selector Switches Contact Block Required 1 Contact Closed 0 Contact Open Contact Block Position Side 2 Side 1 Quantity and Type or or or Mount on Side or or #2 or #2 #2 Left Right Left Right Operator Top View Locating Notch or #1 or #1 # Cam (see page 19-69) E D Non-Illuminated Operators Cat. No. Cat. No. $ Price Manual Return a, Operator Only (without contact blocks) Without Knob KS11 KS With Knob (select style and color from Table below) KS11* KS12* Key Operated with E10 Key (Code1,2,3) KS11K** KS12K** Operator with Contact Blocks and Standard black knob With 1 on Side #2 KS11BH With 1 on Side #1 KS11BH With 1 on Side #1 and 1 on side #2 KS11BH Spring Return from Left a, Operator Only (without contact blocks) Without Knob KS With Knob (select style and color from Table ) KS25* Key Operated with E10 Key (Code 2 only)d KS25K Spring Return from Right a, Operator Only (without contact blocks) Without Knob KS With Knob (select style and color from Table below) KS34* Key Operated with E10 Key (Code 1 only) KS34K Illuminated Operators Cat. No. Cat. No. $ Price Manual Return a, Operator Only (without contact blocks) Without Knob, V Hz Transformer K11J1 K12J With Standard Red Knob, V Hz Transformer K11J1R K12J1R With Other Color Knob and other voltage Light Module b c K11Jbc K12Jbc Spring Return from Left a, Operator Only (without contact blocks) Without Knob, V Hz Transformer K25J With Standard Red Knob, V Hz Transformer K25J1R With Other Color Knob and other voltage Light Module b c K25Jbc Spring Return from Right a, Operator Only (without contact blocks) Without Knob, V Hz Transformer K34J With Standard Red Knob, V Hz Transformer K34J1R With Other Color Knob and other voltage Light Module b c K34Jbc a These operators can be ordered complete with contact blocks. Add the "H code" from page as needed for your application. b Add the voltage assembly code as chosen from page Example: K25Jb with 208 Vac = K25J3. c Add the knob color code from Table For LED, knob color must match LED. d Add the key withdrawal code from Table Table : Selector Switch Assembly Code and Knob Cat. No. Color Standard Knob Gloved Hand Knob c Knob Code Cat. No. c Knob Code Cat. No. $ Price Code Position NOTE: To select and order Contact Blocks, Light Modules, Knobs, and Accessories, see pages through Table : d Key Withdrawal Codes Black B B11 FB B25 1 Left Only Red R R8 FR R Right Only Green G G8 FG G24 3 Left and Right Yellow Y Y8 FY Y24 Blue L L8 FL L White W W8 FW W24 Amber A A8 FA A24 2 Position Clear C C8 FC C Schneider Electric I Discount

2 30 mm Push Buttons Type K, KX, and SK Selector Switch Guide Shown below is a simplified method of selecting a selector switch to meet almost any combination of contact sequences. Step No. 1 Determine the contact sequence(s) required. Set up a target table like the one shown for the example below. Contact Sequence 0 contact open 1 contact closed A B C Step No. 2 Look for a cam type common to all sequences in table Table , Table , or Table For the example above, Table would be used. For the contact sequences A (1 0 0), B (0 1 0) and C (0 0 1) of the example above, cam types F and L are common to all three sequences. Step No. 3 Next, use the cam type common to all the sequences (if several cam types are common, choose one) to find the operator type number. Go to the proper page number as indicated in the table below: Number of Positions Push Button Line Page Number 2 Type K, Type SK, Type KX 19-66, 19-76, 19-84, 19-91, Type K, Type SK, Type KX 19-67, 19-77, 19-84, 19-91, Type K, Type SK, Type KX 19-68, 19-78, If for the example above a manual return operator with a standard black knob is required and: The F cam type is chosen, the operator type number is: Type K Class 9001 Type KS46B (from page19-67) Type SK Class 9001 Type SKS46B (from page 19-77) Type KX Class 9001 Type KXSDFB (from page 19-93) The L cam type is chosen, the operator type number is: Type K Class 9001 Type KS401B (from page 19-67) Type SK Class 9001 Type SKS401B (from page 19-77) Type KX Class 9001 Type KXSDLB (from page 19-93) Step No. 4: Determine the contact blocks required by using the same table in Step No. 2. If, for the example above, the F cam type is chosen: Use a 9001 mounted on side no. 2 for sequence A (1 0 0). Use a 9001 mounted on side no. 1 for sequence B (0 1 0). Use a 9001 mounted on side no. 1 or 2 for sequence C (0 0 1). If, for the example above, the L cam type is chosen: Use a 9001 mounted on side no. 2 for sequence A (1 0 0). Use a 9001 mounted on side no. 1 or a 9001 mounted on side no. 2 for sequence B (0 1 0). Use a 9001 mounted on side no. 1 for sequence C (0 0 1). One Type double circuit block can be used in place of one Type single circuit block plus one Type single circuit block mounted on the same side. Table : 2 Position Selector Switch If you require contact sequence Use Cam Type Use Mount on Contact side no. Block Type (See page 19-84) E 1 or 2 D 1 or 2 E 1 or 2 D 1 or 2 Table : 3 Position Selector Switch If you require contact sequence Use Cam Type Use Contact Block Type Mount on side no. (See page 19-84) G M 1 L 2 C E 1 B C E F G J 2 B G J KA5a 2 D E J L 1 D E 2 F 1 L 2 C F 1 or 2 B D G L 1 D 2 B KA5a 1 M 2 B 1 C F KA5a 1 or 2 M 2 B G J 2 G KA5a 1 L KA5a 2 M 1 J 1 D E J L KA5a 1 D E KA5a 2 Table : 4 Position Selector Switch If you require contact sequence Use Cam Type Use Contact Block Type Mount on side no. (See page 19-84) H (A) H (B) H (C) H (D) H A & D Wired in Parallel H A & B Wired in Parallel H B & C Wired in Parallel H C & D Wired in Parallel H A, B & C Wired in Parallel H B, C & D Wired in Parallel H A & C Wired in Parallel H B & D Wired in Parallel H KA5a H KA5a 1 a Type KA5 must be the last block on either side. If more than one KA5 is required on either side contact your local Square D sales office. Note: For Outline Dimensions see Catalog 9001CT = + = + When ordering, please specify: Quantity Class Number Type or Catalog Number For H Numbers page Schneider Electric CP1 Discount 19-69

3 Push Buttons and Pilot Lights Selection Guide Refer to Catalog 9001CT0001 Family XB4 XB5 9001K 9001SK 9001KX Type of Product 22 mm Push Button (metal) Mounting Hole Diameter 22.5 mm 22.5 mm Approvals Conforming to Standards Degree of Protection UL Listed File E164353, CCN NKCR UL Recognized File E CCN NKCR2 CSA File LR mm Push Button (plastic) UL Listed File E164353, CCN NKCR UL Recognized File E , CCN NKCR2 CSA File LR mm (1.22 in) 30 mm Push Button (metal) 30 mm Push Button (plastic) 31 mm (1.22 in) 31 mm (1.22 in) 30 mm Push Button (metal, square) UL File E CCN NKCR UL File E CCN NKCR UL File E CCN NKCR CSA File LR CSA File LR CSA File LR CE Marked CE Marked CE Marked CE Marked CE Marked EN/IEC , EN/IEC , EN/IEC , EN/IEC EN/IEC and EN/ISO 13850: 2006 (trigger action and mechanical latching emergency stop push buttons) EN/IEC (emergency switching of mechanical latching push buttons) EN/IEC , EN/IEC , EN/IEC , EN/IEC EN/IEC and EN/ISO 13850: 2006 (trigger action and mechanical latching emergency stop push button). EN/IEC (emergency switching of mechanical latching push buttons) EN81-1 (emergency stop trigger action and mechanical latching push buttons with mechanical state indicator) EN/IEC EN/IEC EN/IEC EN/IEC EN/IEC EN/IEC JIS C 4520 JIS C 4520 JIS C 4520 and 852 JIS C 4520 and 852 UL 508 UL 508 UL 508 UL 508 CSA C22.2 No.14 CSA C22.-2 No.14 CSA C22.2 No.14 CSA C22.2 No.14 IP65 IP65 IP66 IP66 IP66 IP66 for booted IP66 for Booted NEMA 1, 2, 3, 3R, 4, 12, 13 NEMA 1, 2, 3, 3R, 4, 4X, 12, 13 NEMA 1, 2, 3, 3R, 4, 4X, 12, 13 NEMA 1, 2, 3, 4, 12, 13 NEMA 1, 2, 3, 4, 4X, 12, 13 Electric Shock Protection Class I Class I Class II Class II Class II Electrical Consumption LED Rated Operational Characteristics Connection Type Cable Size 24 Vac/Vdc: 18 ma 24 Vac/Vdc: 18 ma 120 Vac: 14 ma 120 Vac: 14 ma 240 Vac: 14 ma 240 Vac: 14 ma AC-15; B600 Ue = 600 Vac and le = 1.2 A Ue = 240 Vac and le = 3A Ue = 120 Vac and le = 6A Screw Terminal: 2 x 14 AWG (2.5 mm²) max. 2 x 16 AWG (1.5 mm²) max. Screw or Spring Terminal AC-15; B600 Ue = 600 Vac and le = 1.2 A Ue = 240 Vac and le = 3 A Ue = 120 Vac and le = 6 A Ue = 250Vdc and le = 0.27 A Spring Terminal: 2 x 14 AWG (2.5 mm²) max. 2 x 16 AWG (1.5 mm²) max. AC-15; A600 2 x 16 AWG (1.5 mm²) max AC-15; A600 Screw Terminal 2 x 16 AWG (1.5 mm²) max Digest Page AC-15; A600 1 x 24 AWG (0.2 2mm²) min. 2 x 16 AWG (1.5 mm²) max Schneider Electric 19-3

4 30 mm Push Buttons Type K, SK and KX Electrical Components For use in hazardous locations See page With neon type light modules, use a clear color cap only. With LED light modules, use either a clear color cap or a cap the same color as the LED. 19 Table : Standard Light Modules for Types K, SK, and KX Control s b a b Voltage Description Not for use on KX operators. For use with all operators except KX and remote test pilot. NOTE: Light modules are available in other voltages. For additional information, refer to Catalog 9001CT0001. For use in hazardous locations See page Reduces the depth of illuminated push buttons with contact blocks by over 33%. With LED light modules, use a cap that is the same color as the LED. Light Module Voltage Replacement Lamp Assembly Rating Type $ Price Code Part Number b $ Price All Full Voltage (without Bayonet Base Lamp) KM None 6 Vac/Vdc Full Voltage KM VA Vac/Vdc LED Red KM31LR LR Vac/Vdc LED Green KM31LG LG Vac/Vdc LED Yellow KM31LY LY Vac/Vdc Full Voltage KM VA Vac/Vdc LED Red KM32LR LR Vac/Vdc LED Green KM32LG LG Vac/Vdc LED Yellow KM32LY LY Vac/Vdc Resistor KM VA Vac/Vdc Full Voltage KM VA Vac/Vdc LED Red KM35LR LR.28 VA Vac/Vdc LED Green KM35LG LG.28 VA Vac/Vdc LED Yellow KM35LY LY.28 VA Vac/Vdc LED White KM35LW LW.28 VA Vac/Vdc LED Blue KM35LL LL.28 VA Vac/Vdc Full Voltage KM VA V, Hz LED Red KM1LR LR V, Hz LED Green KM1LG LG V, Hz LED Yellow KM1LY LY V, Hz Transformer KM VA V, Hz Flashing KMF F1.85 VA Vac/Vdc Resistor KM VA Vac/Vdc Full Voltage KM VA Vac/Vdc Neon a KM VA Vac/Vdc LED Red KM38LR LR 1.4 VA Vac/Vdc LED Green KM38LG LG 1.4 VA Vac/Vdc LED Yellow KM38LY LY 1.4 VA Vac/Vdc LED White KM38LW LW 1.4 VA Vac/Vdc LED Blue KM38LL LL 1.4 VA V, Hz Transformer KM VA V, Hz LED Red KM3LR LR V, Hz LED Green KM3LG LG V, Hz LED Yellow KM3LY LY V, Hz Transformer KM VA V, Hz LED Red KM7LR LR V, Hz LED Green KM7LG LG V, Hz LED Yellow KM7LY LY Vac/Vdc Resistor KM VA Vac/Vdc Neon a KM VA V, Hz Transformer KM VA V, Hz Transformer KM VA Vac/Vdc Neon a KM VA V, Hz Transformer KM VA Table : Shallow Depth Light Modules For Types K and SK Control s c Voltage Description Light Module Voltage Assembly Replacement Lamp Code Rating Type $ Price Part Number $ Price Full Voltage KM VA Vac/Vdc LED Red KM55LR 55LR LED Green KM55LG LG 0.5 VA LED Yellow KM55LY 55LY Full Voltage KM VA Vac/Vdc LED Red KM58LR 58LR LED Green KM58LG LG 0.5 VA LED Yellow KM58LY 58LY c For use with all operators except KX and remote test pilot. NOTE: When ordering, add prefix 9001 to the catalog number. File CCN E42259 NKCR File Class LR marked Schneider Electric CP10 CP1 Discount

5 30 mm Push Buttons Type K, SK and KX Contact Block H Numbers Example: A Type KR1B push button with 2 Type contact blocks would be Class 9001 Type KR1BH2. POS 2 POS 4 POS 6 POS 1 POS 3 POS 5 Side 1 Side 2 Locating Nib The design of the Class 9001 Type KA contact blocks allows them to be mounted side by side and/or in tandem. This enables you to specify an operator and a particular arrangement of contact blocks (shipped completely assembled) with a single Type number. See page for a description of contact blocks. Table : H Codes Suffix No. (Add to Operator Type) $ Price Positions H H H H H H H H H KA4 H KA4 KA5 H H H H H H H H H H H H H KA5 NOTE: For H Codes not shown in this table, contact your local Schneider Electric representative. Maximum Contact Block Usage (Includes Types K, SK and KX) 2 blocks mounted side by side only: Any 2, 3 or 4 position spring return selector switch (non-illuminated, illuminated or keyed). 2 blocks mounted in tandem on one side only: Any 2 operator interlocked push button. 2 blocks mounted in tandem (total of four blocks): Any selector push button, keyed push button, 2, 3, or 4 position maintained selector switch (non-illuminated, illuminated or keyed), push-pull operators (non-illuminated or illuminated), joy stick, dual push button. 3 blocks mounted in tandem (total of six blocks): Single momentary push buttons (non-illuminated or illuminated). Table : Dimensions When Using Contact Blocks Panel Thickness.06 min Standard Blocks max Panel Thickness 1/16 min.-1/4 max Reed Blocks Mounting Hole for All Types K, SK, and KX Control s Dia Hole Punch: Use Greenlee Tool #60242 to punch mounting hole and notch. Light Module KA KA KA KA 19 *1.22 Dia. Preferred 31 Cover Drilling A * 1.22 Dia. 31 *s also mount in 1.20 dia. 30 Alternate Cover Drilling Dual Dimensions: INCHES Millimeters KA KA KA KA Enclosure or Grounded Metal Part D 1.13 D Table : Basic Operators (Without Color Caps, Mushroom Buttons, Knobs, Selector Switch Cams, Contact Blocks, Light Modules, or Legend Plates) For UL Types/NEMA Description 1, 3R, 4, 12, 13 4, 4X, 13 $ Price Non-Illuminated Push Button (Extended Guard) KR2 SKR Non-Illuminated Push Button (No Guard) KR3 SKR Non-Illuminated Push Button (Mushroom Button/Screw-On) KR20 SKR Non-Illuminated Dual Push Button (Momentary) KR Non-Illuminated Dual Push Button (Momentary Interlocked) KR Non-Illuminated Dual Push Button (Maintained Interlocked) KR Momentary Pull Maintained Neutral Momentary Push KR8 ad SKR8 a Maintained Pull Maintained Push KR9 ad SKR9 a Illuminated Push Button (Full Guard Plastic Top) K1L b SK1L b Illuminated Push Button and Push-To-Test (No Guard) K2L bc SK2Lbc Illuminated Push Button (Full Guard Metal Top) K3L b Standard Pilot Light KP SKP Position Maintained Selector Switch KS4 a SKS4 a Position Spring Return Both Sides To Center Selector Switch KS5 a SKS5 a Position Spring Return Left To Center Selector Switch KS6 a SKS6 a Position Spring Return Right To Center Selector Switch KS7 a SKS7 a a Operator can be converted to an illuminated operator by removing the liner ( ) and adding a light module. b Operator can be converted to a non-illuminated operator by adding liner ( ). c Operator includes jumper wires for push-to-test conversion. d These operators can be supplied with 1-3/8 in or 2-1/4 in dia. mushroom buttons. For 1-3/8 in.: add ( ) 20 to type number. The ( ) refers to the color chosen see page For 2-1/4 in.: Add ( ) 21 to type number. The ( ) refers to the color chosen see page Voids UL and NEMA 6 Rating. Light Module Light Module Schneider Electric CP1 Discount

6 19 30 mm Push Buttons Type K and SK Accessories Table : Legend Plates Special Marking Legend Plate KN100( )P (Plastic) a 2.25 in Square KN200 KN200( )P (Plastic) a 1.7 in. Square KN300 KN400 KN500 KN600 KN700( )P (Plastic) a 2.5 in. Square KN800 KN900 Description Type $ Price Silver Field, Black Letters KN199SP Special Marking White Field, Black Letters KN199WP, Black Letters KN199RP Black Field, White Letters KN199BP Special Marking Black Field KN299 KN299R Silver Field, Black Letters KN299SP Special Marking White Field, Black Letters KN299WP, Black Letters KN299RP Black Field, White Letters KN299BP Special Marking Black Field KN399 KN399R Blank KN Any Marking b KN Standard Markings Select from Table Black Field KN599 Special Marking b Green Red Field KN519 Blank Black Field KN600 Red Field KN600R 9.90 Any Marking Black Field KN699 KN699R Standard Markings Select from page Silver Field, Black Letters KN799SP Special Marking White Field, Black Letters KN799WP, Black Letters KN799RP Black Field, White Letters KN799BP Standard Markings Select from page Special Marking Blue Field KN899 KN899R Blank KN Any Marking b KN999 a Other colors available (see Table ). b Specify marking required. Table : Plastic Legend Plates Other Colors Blank Legend Plates Special Engraved Legend Plates Plate Color Letter Color 1.7 in. Square 2.25 in. Square 2.5 in. Square $ Price Yellow Black KN200YP KN100YP KN700YP Green KN200GP KN100GP KN700GP Blue KN200LP KN100LP KN700LP White 4.40 Red KN200CP KN100CP KN700CP Orange KN200AP KN100AP KN700AP Burnt Orange Black KN200HP KN100HP KN700HP Yellow Black KN299YP KN199YP KN799YP Green KN299GP KN199GP KN799GP Blue KN299LP KN199LP KN799LP White Red KN299CP KN199CP KN799CP Orange KN299AP KN199AP KN799AP Burnt Orange Black KN299HP KN199HP KN799HP Table : Maximum Number of Lines and Characters for Type KN Legend Plates Type KN100 KN200 KN300 KN400 KN500 KN600 KN700 KN800 KN900 Max. No. of Characters per Line Max. No. of Lines Note: per field per field The maximum number of characters and lines is a practical maximum, based on a minimum size of characters to facilitate easy reading per pos. 1 per pos. Table : Circular Legends for Emergency Stop Mushroom Heads (yellow background) Diameter Text Catalog Number $ Price 9001KN mm EMERGENCY STOP 9001KN KN mm EMERGENCY STOP 9001KN8330 Table : Min. Centerline Spacing, Type K & SK Control s Centerline Spacing (in.) Legend Plate Operator A B C D E F Legend Plate Orientation Position #1 Standard Push Button KN in. Dia. Mushroom KN5 Selector Switch Knobs Standard Push Button KN in. Dia. Mushroom Selector Switch Knobs Standard Push Button KN in. Dia. Mushroom Selector Switch Knobs Standard Push Button KN in. Dia. Mushroom in. Dia. Mushroom Selector Switch Knobs Legend Plate Position #2 Legend Plate Orientation Position #2 KN2 KN5 KN3 KN4 KN6 Legend Plate Position #1 Standard Push Button in. Dia. Mushroom Selector Switch Knobs Standard Push Button in. Dia. Mushroom Selector Switch Knobs Standard Push Button in. Dia. Mushroom Selector Switch Knobs Standard Push Button in. Dia. Mushroom in. Dia. Mushroom Selector Switch Knobs Table : Special Legend Plates Type KN500 (For Use with Dual Function Operators: KR6, KR7 and KR67) Standard Markings Type Green Red KN500 Blank Blank KN501 Start Stop KN502 On Off Type Black Black KN520 Blank Blank KN521 Start Stop KN522 On Off KN523 Forward Reverse KN524 Up Down KN525 High Low KN526 Open Close NOTE: When ordering, add prefix 9001 to the catalog number Schneider Electric CP1 Discount

30 mm Push Buttons 9001 K and SK Selector Switches

30 mm Push Buttons 9001 K and SK Selector Switches www.schneider-electric.us 30 mm Push Buttons 9001 K and SK Selector Switches NOTE: To order, add prefix 9001 to the beginning of the catalog number. Table 19.181: 3-Position Selector Switches Contact Block

More information

30 mm Push Buttons 9001 K and SK Selector Switches

30 mm Push Buttons 9001 K and SK Selector Switches 30 mm Push Buttons 9001 K and SK Selector Switches NOTE: To order, add prefix 9001 to the beginning of the catalog number. Table 19.184: 4-Position Selector Switches Contact Block Position Side 2 Side

More information

30 mm Push Buttons Type SK Corrosion Resistant Multifunction Operators

30 mm Push Buttons Type SK Corrosion Resistant Multifunction Operators 30 mm Push Buttons Type SK Corrosion Resistant Multifunction Operators Table.207: 30 mm Multifunction Operators UL Types 4, 4X, 13/NEMA 4, 4X, 13 Non-Illuminated Push-Pull Screw-on Mushroom Operators Color

More information

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature

More information

SQM40/41 Actuators for air and gas dampers

SQM40/41 Actuators for air and gas dampers SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The

More information

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A 72 Power Series SPDT 20 A; DPDT 15 A UL listed when used with proper Magnecraft sockets The 72 Plug-in Power relays offer clear or full-feature covers with multiple mounting options and accessories. Feature

More information

Safety dialogue solutions

Safety dialogue solutions Characteristics 5 Environment Conformity to standards Products XY2 CH, XY2 CE: EN/IEC 60947-5-1, EN/ISO 13850:2006, UL 508 and CSA C 22-2 n 14 (with suffi x H7) XY2 CB: EN/IEC 60947-5-1, EN/ISO 13850:2006,

More information

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B Contactors Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business

More information

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B 11 Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business machines

More information

Panel Mount Signaling Alarms

Panel Mount Signaling Alarms Panel Mount Signaling Alarms Bulletin 855P Panel Mount Signaling Alarms Build a Catalog Number Mounts in standard 22.5 mm hole Watertight panel alarms in three different sizes Sound output 72 105 db @

More information

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA .5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................

More information

Quick-disconnect cables. Adjustable mounting brackets

Quick-disconnect cables. Adjustable mounting brackets MiniSafe File No. LR90200 Description A MiniSafe consists of an identical length transmitter and receiver, combined with an STI Universal or DuoSafe Controller and appropriate interconnecting cables. The

More information

Quick-disconnect cables. Adjustable mounting brackets

Quick-disconnect cables. Adjustable mounting brackets MiniSafe File No. LR90200 Operation MiniSafe 1.0 inch (25.4 mm) resolution 100 foot (30.5 m) range Individual Beam Indicator lights covered by U.S. and international patents Compact size 2.25 x 1.8 inches

More information

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models Indicator (Rectangular) CSM DS_E_4_1 Large Rectangular-bodied Indicators Excellent illumination with even surface brightness. Three-color (green, orange, red; chameleon lighting) included in lineup. Refer

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

LW Series offer flexibility in space-saving package

LW Series offer flexibility in space-saving package ø22mm - W Series Oiltight W Series Switches and Pilot Devices: 22mm W Series offer flexibility in space-saving package Key features include: P board mount, solder or screw terminal ollective mounting saves

More information

ALLEN BRADLEY TIMING RELAY

ALLEN BRADLEY TIMING RELAY ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY

More information

Solid-State Digital Timer

Solid-State Digital Timer Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,

More information

Model Number Structure

Model Number Structure Cycle Control Units CSM DS_E_7_1 Refer to Safety Precautions for All Power Controllers. Used in Combination with the to Enable High-precision Temperature Control Use cycle control to achieve power control

More information

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets MicroSafe MCF4700 C US File No. LR90200 MicroSafe Flexible MCF4700-12, MCF4700-20, MCF4700-30 12 mm, 20 mm and 30 mm resolution versions Compact segmented light curtain 1.02 inch (26 mm) x 1.1 inch (28

More information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information Box Fan R87B CSM_R87B_DS_E_4_4 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.

More information

AS09..S 3-pole Contactors - Spring Terminals

AS09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional

More information

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT FN: 341MAN1.DOC AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT DESCRIPTION AE Series Process Indicators are available with 1", 2.3", 4", 8", or 12" high digits,

More information

High performance circuit breakers

High performance circuit breakers Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics

More information

TeSys circuit-breakers

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers type GV2-ME GV2-ME with pushbutton control and screw clamp terminals (1) Standard power ratings Setting Magnetic Reference Weight of -phase motors range tripping

More information

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models

M2P. Large Rectangular-bodied Indicators. Indicator (Rectangular) List of Models Indicator (Rectangular) CSM DS_E_3_2 Large Rectangular-bodied Indicators Excellent illumination with even surface brightness. Three-color (green, orange, red; chameleon lighting) included in lineup. Refer

More information

Lighted Pushbutton Switch (Square) Ultra Bright LED Type

Lighted Pushbutton Switch (Square) Ultra Bright LED Type New Products Lighted Pushbutton Switch (Square) Ultra Bright LED Type Large Square-bodied Lighted Pushbutton Switches New models added with Ultra LEDs. New models with ultra bright LEDs added to single-screen

More information

AC1036. Definite Purpose Contactors

AC1036. Definite Purpose Contactors Definite Purpose Contactors Definite purpose contactors Definite purpose Contactors Applications Type DP contactors provide high performance with flexibility and reliability, designed to match numerous

More information

LAMPS & INDICATOR LAMPS

LAMPS & INDICATOR LAMPS LAMPS & INDICATOR LAMPS 10.5 M16 x 1.0 55-056-0 Bulk 12V140mA lead wire lamp 55-056-2 Display Package (2) 19.5 14.0 12.0 20.4 7.5 50.4 55-120-0 Bulk NE-2 Neon bulb 55-120-2 Display Package (2) T 3-14 (10mm)

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

XT Line Replacement Coils 16.1 NEMA Contactors and Starters Freedom Line... A200 Line IEC Contactors and Starters XT Line...

XT Line Replacement Coils 16.1 NEMA Contactors and Starters Freedom Line... A200 Line IEC Contactors and Starters XT Line... XT Line Replacement s.1 Freedom Line............................................ A200 Line............................................... Lighting Contactor Magnetic.2 IEC Contactors and Starters XT Line..................................................3

More information

llen-bradley 194R-HM4-NFPA3

llen-bradley 194R-HM4-NFPA3 Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure Box Fan R87B CSM_R87B_DS_E_4_2 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.

More information

Photoelectric Sensors E3F2

Photoelectric Sensors E3F2 Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel

More information

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors C7 Series C7 Special Use designed and labeled for specific industrial applications The C7 line includes a number of contactors designed and labeled for specific industrial applications. In most cases,

More information

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection... IEC ors and Starters. Contents Description Catalog Number Selection................ Product Selection....................... Accessories........................... Technical Data and Specifications..........

More information

For Sales & Information, Call Toll Free: (888)

For Sales & Information, Call Toll Free: (888) PCR Outline Dimensions 2.75" (69.8 mm) 0.44" (11 mm) 0.25" (6.3 mm) (-) (+) 15.8" (401 mm) 9.3" (236 mm) Nameplate 1.25" (31.8 mm) 3.0" (76 mm) 7.40" (188 mm) 12.63" (321 mm) R 0.219" (R 5.56 mm) Serial

More information

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A - 400 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors PPLINCES /// MT, CST-100 II ND SL-156 CONNECTORS CONNECTORS/ PPLINCES MT, CST-100 II and SL-156 Connectors Contents Introduction This catalog has been designed to assist you, our customer, identify products

More information

Azatrax Model Railroad Track Signal Control - Single Track

Azatrax Model Railroad Track Signal Control - Single Track Installation Guide Azatrax Model Railroad Track Signal Control - Single Track TS2 What it is: The TS2 operates one or two trackside block signals (one in each direction) on one track to simulate the block

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil Price* : 4058.00 USD has not been replaced. Please contact your customer care center for more information. Main Range

More information

Cast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View)

Cast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View) 30A 400A (30 200A Load Breaking), Maximum 600VAC/250VDC Receptacles, Inlets, Plugs, Connectors, Interlocked Receptacles, Explosion-Proof Interlocked Receptacles Cast Aluminum Circuit Breaker Interlocked

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

Magnecraft Power Relays

Magnecraft Power Relays Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These

More information

Safety Light Curtains GuardShield

Safety Light Curtains GuardShield Description The Allen-Bradley Guardmaster safety light curtain is an economical, fully featured, Type 4 safety light curtain in a uniquely styled housing. safety light curtains are general purpose presence

More information

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US Low Signal Relay G6A Fullly Sealed Relay with High Impulse Withstand High sensitivity can be driven by digital circuits. Low-profile design allows use in 12.70 mm PC board rack. Surge withstand meets FCC

More information

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min Weekly Time Switch Easy Programming with Large LCD Display and Interactive Functions Programming for 24 hrs x 7 days using just five switches. Sixteen program steps available. Power supply freely selectable

More information

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors Differential Sensor Micropressure Sensor with Easy-to-Read Digital Repeat accuracy of ±1% FS (setting resolution: 0.01 kpa), high-precision pressure control available. Compact design (31 mm) saves mounting

More information

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements NO: PH-165 PRODUCT: E3S-X3, E3X-NL, E3X-NM DATE: August 2012 TYPE: Discontinuation Update Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements Affected

More information

INDICATOR LAMPS & LED REPLACEMENT LAMPS

INDICATOR LAMPS & LED REPLACEMENT LAMPS INDICATOR LAMPS & LED REPLACEMENT LAMPS Neon indicators (internal resistor) 120VAC 55-452-0 Red lens 120VAC 55-453-0 Amber lens 120VAC 55-455-0 Green lens 120VAC Neon indicators (internal resistor) 120VAC

More information

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Panel cutout required: 1.772 x 3.622 (45mm x 92mm) 1.76 (45mm) 2.45 (62mm) 3.20 (81mm) 3.60 (91mm) 0.59 (15mm) Special Features NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and

More information

Series CDP2 Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors Series 2 Definite Purpose High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air

More information

APPLICATIONS. Automatic warehouse. Trasportation lines

APPLICATIONS. Automatic warehouse. Trasportation lines INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information

TOKISTAR TOKISTAR LIGHTING

TOKISTAR TOKISTAR LIGHTING L i g hts tr ing s TOKISTAR TOKISTAR LIGHTING Lightstrings T okistar Lightstrings are a system of sockets wired in parallel and permanently attached to flexible, commercial-grade wire. All-weather construction

More information

Product Type Description Industrial Horn. Horn Type

Product Type Description Industrial Horn. Horn Type Overview/Product Selection Bulletin 855H Industrial Electronic Horns with Optional Strobe Beacon IP56/UL Type 13/3R ecibel Range 100...126 db Up to 45 Selectable Tones Up to 3 Individual Circuits in each

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 850-... Description Single, two, three and four pole magnetic and hydraulic-magnetic circuit breakers with trip-free-mechanism and toggle or rocker actuation.

More information

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page 3a Enclosed Type Molded Plastic Compact Design Impact-Resistant Molded Enclosures IP42 (Type 1) or IP66 (Type4/4X/12)Enclosure Ratings Solid-State Overload Relays Meets International Standards 109-C09KDA1E-1-4R1-7

More information

7 SEGMENT LED DISPLAY KIT

7 SEGMENT LED DISPLAY KIT ESSENTIAL INFORMATION BUILD INSTRUCTIONS CHECKING YOUR PCB & FAULT-FINDING MECHANICAL DETAILS HOW THE KIT WORKS CREATE YOUR OWN SCORE BOARD WITH THIS 7 SEGMENT LED DISPLAY KIT Version 2.0 Which pages of

More information

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubSat4D - Four (4) Channel Passive UTP Transceiver Hub with Integral HubSat42D - Four (4) Channel Passive UTP Transceiver includes

More information

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71. Optical SERIES 61K High Resolution, 4-Pin FEATURES 25, 32, 50, 64, 100, 128 and 256 Cycles per Revolution Available Sealed Version Available Rugged Construction Cable or Pin Versions 10 Million Rotational

More information

MiniSafe Light Curtains

MiniSafe Light Curtains r Safety Light Curtains MS600 MS600 MiniSafe Light Curtains Resolution: mm (0. in.), 9 mm (0.7 in.) or 0 mm (.8 in.) resolution Range: 7. m ( ft.) range for the mm resolution, 0 m (6 ft.) range for the

More information

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors SSN9000 Series C7 Special Use designed and labeled for specific industrial applications Special Use Capacitor switching contactors HVC rated contactors NEM size labeled contactors Lighting contactors Hydraulic

More information

Specifications. Response Time. Status Indicators. Scanning Range/Resolution. Vibration. Shock. Physical Characteristics.

Specifications. Response Time. Status Indicators. Scanning Range/Resolution. Vibration. Shock. Physical Characteristics. Features Standard Fixed blanking teachable Floating blanking One-beam floating blanking on 0 mm resolution Two-beam floating blanking on mm resolution Beam coding External Device Monitoring (EDM) Start/restart

More information

Bulletin 305 AC Starters

Bulletin 305 AC Starters Bulletin 305 AC Starters Bulletin 305 NEMA AC Starters NEMA sizes 0 2 Cost saving design E1 Plus electronic overload relays Compact size Bulletin 305 reversing starters are most commonly used for full-voltage

More information

Bright and Various Illumination makes easy planning of multiple design. Easy Matrix Mounting available. Dome Cover type (easy to look) provided.

Bright and Various Illumination makes easy planning of multiple design. Easy Matrix Mounting available. Dome Cover type (easy to look) provided. LED Indicator LED BL Bright and Various Illumination makes easy planning of multiple design. Easy Matrix Mounting available. Dome Cover type (easy to look) provided. Various illumination (Mono Color,Split-Face,

More information

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range Installation Manual Table of Contents Basic Operation...2 CR-R880-BL Block Diagram...2 Technical Specifications...3 Features...4

More information

Series CDP2 Definite Purpose Contactors

Series CDP2 Definite Purpose Contactors Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications

More information

HS-509 VIBRATION TRIP MODULE

HS-509 VIBRATION TRIP MODULE HS-509 VIBRATION TRIP MODULE 1. Overview The HS-509 is a configurable trip amplifier capable of accepting a 4-20mA signal from a HS-420 sensor and providing two trip action relay outputs along with an

More information

Bulletin 190 IEC Modular Starter System

Bulletin 190 IEC Modular Starter System Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................

More information

Safety Light Curtains

Safety Light Curtains 4 Safety Light Curtains F3SJ-A Safety Light Curtains Resolution: 14 mm (0.55 in.), 20 mm (0.79 in.), 25 mm (1.01 in.) 30 mm (1.18 in.), or 55 mm (2.17 in.) Range: 7 m (23 ft.) or 9 m (29.5 ft.) dependent

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1) 80 South Street 7596-726, TX Nacogdoches Phone: 96-569-79 Fax: 96-560-685 XTCE007B0A PH FVNR 7A IEC Contactor Eaton Corp Catalog Number XTCE007B0A Manufacturer Eaton Corp Description Magnetic Contactor,

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

Manual Motor Starter Specifcations

Manual Motor Starter Specifcations Technical Data Manual Motor Starter Specifcations Bulletin 140A Topic Page Product Selection 2 Accessories 3 Specifications 6 Approximate Dimensions 13 Additional Resources These documents contain additional

More information

4 Wiring Brochure Wiring and installation of specific control

4 Wiring Brochure Wiring and installation of specific control - Wiring Brochure tekmarnet 4 User Switch 480 W 480 09/09 1 Information Brochure Choose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel OWNERS MANUAL Revision 1.8 09/01/2002 OWNERS MANUAL Page 2 of 12 AR-1202 UNIT DESCRIPTION The AR-1202 consists of a processor and 12 dimmer channels of 2.4KW each. Each dimmer channel is protected by a

More information

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with

More information

Type Contact form Model

Type Contact form Model Low Signal Relay G6A High sensitivity can be driven by digital circuits. Low-profile design allows use in.70 mm (0.50 in) PC board rack. Surge withstand meets FCC Part 68 regulation. Units can be mounted

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer

More information

Photoelectrics Through-beam Type PA18C.T..., DC

Photoelectrics Through-beam Type PA18C.T..., DC Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:

More information

Level Measurement silometer FMC 420, FMC 423

Level Measurement silometer FMC 420, FMC 423 Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level

More information

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview 13 6.3 13 6.3 4.7 20.7 24.6 +1/-0 24.6 +1/-0 2.5 24.6 +1/-0 20.7 4.3 +0.3-0.4 3.6 ±0.3 32.5 32.5 32.5 5 2 CONTACT-DUO-PROFILE Contact-Duo-Profile overview 13 6.3 13 6.3 4.7 2.5 16±0.8 4.7 2.5 4.7 2.5 2.6

More information

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications . Ex-Escape sign luminaires Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications The robust escape sign luminaire The Ex-Lite series of explosion-protected escape sign luminaire

More information

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz. HVAC Farm Duty Brake 200 & 575 Volt & Controls DC 310 DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound DC & Controls 1/4-2 Hp 115/ 1 Phase 50/60 Hz. Applications: General purpose industrial use with

More information

Illustrated Feature. Options

Illustrated Feature. Options Applications Enclosed and gasketed fixtures for use where vapors, moisture, dirt or corrosive atmospheres are encountered. For use in hazardous locations defined by the NEC as Class I, Division 2. Groups

More information

DATA SHEET Panorama Rudder Indicator, TRI-2

DATA SHEET Panorama Rudder Indicator, TRI-2 DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating

More information