Installation & Operations Manual
|
|
- Rolf Ellis
- 5 years ago
- Views:
Transcription
1 Lytespan Track Lighting Addressable Track Module System Installation & Operations Manual For Use with Catalog Numbers: CAM250VA, CAM250ND, CAMTM, CAMWRC, & CAMLRC
2 Table of Contents 1. System Overview Understanding the Components Addressable Track Dimming Module (DM) CAM250VA Addressable Track Non-Dimming On/Off Module (NDM) CAM250ND Addressable Track Master Module (TM) - CAMTM Laser Remote Control (LRC) - CAMLRC Wall Remote Control (WRC) - CAMWRC Installation of Modules to Lytespan Track Systems ATOM Laser Remote Control (LRC) Feature Overview Replacing Batteries First Time Installation & Test Checklist Programming ATOM (Basic) Programming Modules Programming A System Programming ATOM (Advanced Features) Operation of the ATOM System Operating Commands System Overview Created to work with Lytespan Radius, Basic, and Advent Track and all Lytespan Track Heads, ATOM is easily installed and requires no special wiring. A simple hand-held Laser Remote Control (LRC) allows the user to first activate the system with a laser, and then program individual or multiple Track heads using infrared signals. Easily retrofitted to existing installations, ATOM offers even more flexibility and control than multi-circuit track. ATOM provides up to six programmable scenes plus On/Off scenes, programmable time delays, fading effects, and cycle effects by grouping fixtures on the same sequence. When integrated with Lightolier Controls Compose PLC Firewall (CPLCFW4 & CPLCFW8), ATOM can communicate across multiple circuits of Track to provide the ultimate in lighting control. Ideal for dimming incandescent and low-voltage fixtures with the Addressable Track Dimming Module (DM), ATOM also controls non-dimming compact fluorescent and metal halide sources with the Addressable Track Non-Dimming On/Off Module (NDM). Additional components of the system consist of: Addressable Track Master Module (TM) - permits scene control via line carrier signal among Addressable Track Dimming and Addressable Track On/Off Modules. Wall Remote Control (WRC) - A hard wire unit will interface with ATOM TM & Lightolier Controls Compose System. In-Line Filter (CPLCILF20) Recommended for each track circuit with an ATOM installation. Reduces unwanted electrical noise on track circuit. ATOM is compatible with Lightolier Controls Compose System Factory Defaults Troubleshooting Appendix Understanding the Components Addressable Track Dimming Module (DM) CAM250VA Individually addressable module that mounts anywhere along the track and accepts any Lytespan Line & Low Voltage Incandescent luminaire (see luminaire compatibility for exceptions) for the purpose of addressing a selected single luminaire for raising and lowering the light level (dimming) or switching On/Off, while powered by the same track. Programmable to store desired light levels of single luminaires or to group with two or more luminaires within the same system for the purpose of creating light scenes and effects (including kinetic lighting effects) Luminaire Compatibility: Module can be used with any Lytespan Line & Low Voltage Incandescent luminaire, 250W Max. DO NOT USE with Power Jack, Metal Halide, Fluorescent, or Convenience Outlet Units See individual luminaires instruction sheet for installation into Module. 2 3
3 IR & LASER RECEIVER (Target area for laser & IR signals) RED LED Addressable Track Master Module (TM) - CAMTM Sends control signals along the track to other modules from any location on the track. Used to create cycles, scenes, lighting effects, and dim, raise, or turn on or off the light levels on all modules on the track simultaneously. Use one track master per track branch circuit. Accepts commands from Laser Remote Control and Wall Remote Control units. The Track Master can control up to 17 modules per circuit (To control more than 17 modules, additional circuits must be used and connected with Lightolier Controls Compose Firewall. The Firewall is available in 4 or 8 circuit units.). RED LED Addressable Track Non-Dimming On/Off Module (NDM) CAM250ND Individually addressable module that mounts anywhere along the track and accepts any Lytespan Line & Low Voltage Incandescent, fluorescent, and metal halide luminaire (see luminaire compatibility for exceptions) for the purpose of addressing a selected single luminaire for switching On/Off, while powered by the same track. Programmable to store desired light levels (On or Off) of single luminaires or to group with two or more luminaires within the same system for the purpose of creating light scenes and effects. Luminaire Compatibility : Module can be used with any Lytespan Incandescent line voltage, incandescent low voltage, metal halide, & fluorescent luminaire, 250W MAX. DO NOT USE with Power Jack, Sof-Tech Metal Halide, Lytespots, Powerwash T5 Track Mount, Lyteflood L40 & L39, or Convenience outlet Units See individual luminaires instruction sheet for installation into Module. GREEN LED IR & LASER RECEIVER (Target area for laser & IR signals) Laser Remote Control (LRC) - CAMLRC Used to program the system and change light levels from a remote location. Equipped with a laser and infrared (IR) transmitters. The visible laser signal, when pointed at a module, places the module in program mode. The laser signal accuracy allows a single unit to be selected easily when multiple modules are on the track & the IR signal programs the desired functions. The remote will allow the user to set the light level, turn modules on or off, set and run multiple lighting scenes, set fade rates, set cycle times, and begin and end cycles. The remote operates the Dimming Module, Non-Dim On/Off Module, and Track Master Module. Transmitter IR & LASER RECEIVER (Target area for laser & IR signals) 4 5
4 Wall Remote Control (WRC) - CAMWRC Used to control ATOM Modules from a wall location. The wall remote will allow the user to run multiple programmed lighting scenes and to begin and end cycles. A TM must be used with the Wall Remote Control, to run a cycle. A TM is not needed to switch between scenes. The Wall Remote Control can control up to 17 modules per circuit (To control more than 17 modules, additional circuits must be used and connected with Lightolier Controls Compose Firewall. The Firewall is available in 4 or 8 circuit units.). 3. Installation of Modules to Lytespan Track Systems For detailed installation instructions, see IS:CAM250VA TRACK TRACK BEAD MODULE ATTACHMENT LEVER For detailed installation instructions, see IS:CAMWRC ATTACHMENT LEVER LOCKING LEVER 6 7
5 4. ATOM Laser Remote Control (LRC) The ATOM Addressable Track Dimming, Non-Dimming On/Off, & Track Master Modules have integrated Infrared (IR) & Laser Receivers that allow them to receive IR and Laser commands from the ATOM Laser Remote Control. The ATOM Remote s IR transmitter & Laser are capable of operating over an unobstructed range of approximately 25 feet. Within this range, scenes can be selected, raised and lowered, and lighting can be turned On/Off using the handheld Remote Control. NOTE: This system is based on line-of-sight operations. Therefore, the Module s receiver must be able to "See" the LRC s Transmitter. Any obstruction between the transmitter and receiver may adversely affect the performance of the unit. Feature Overview Multiple modules can be programmed at the same time by aiming the laser at their Target area for Laser & IR signals, thereby selecting them and also placing them into program mode. All modules programmed at the same time will receive the same IR program commands and their scene settings will be identical. Learn: When not in program mode, press this button to make the Module s LED s blink so they can be easily located on the ceiling or wall. Used to save a program (Scenes, Effects, fades, etc.) when pressed while in program mode. or : Used to raise or lower the light level of a luminaire. Can be used at anytime with a TM and can be used on a DM or NDM when in program mode. A B C D E or F : Used to change to different scenes. Can be used at anytime with a TM and can be used on a DM or NDM when in program mode. All of these scenes can be programmed with different light levels and fade rates. Used as a step to program and run cycles. All of these cycles can be programmed with different scene and fade sequences. ON or OFF Used to change to the ON and OFF scenes. Can be used at anytime with a TM and can be used on a DM or NDM when in program mode. The ON scene can be programmed with a different light level and fade rate but the OFF scene can only be programmed with a different fade rate. f Fade: Used as a step to program fade rate. Used to force a fast fade (1.5 seconds) when pressed during a fade. Select: When the button is pressed it will emit a laser beam. The laser beam must be aimed directly at the fixture s receiver target on a module to initiate the module s program mode. This button is the only but ton that will transmit a laser beam; all other buttons transmit an IR beam. c Cycle: Used as a step for programming and running cycles sec. 5 min. 30 min. Used as a step to program fade rates and time delays in scene and cycle commands. b Begin: Used as a step for programming and running cycles. e End: Used to exit any program step without saving. Used to halt a running cycle or fade where it s at. 8 9
6 Replacing Batteries First Time Use: The LRC comes with a protective plastic between the batteries and the contact on the remote to save the battery life during storage. In order for the LRC to work, this plastic should be removed. Remove the battery cover, located on the back of the remote, by snapping it off in the direction shown. Pull out the protective plastic and make sure the batteries are pushed completely in. Snap the cover back on. When buttons are depressed, the LRC s LED should light up. There is also a protective cover on the front of the remotes keypad that should be removed. Replacing Batteries: Remove battery cover, located on back of remote, by snapping it off in the direction shown. Pull out the old batteries. Replace with (2) 3V CR2025 with the positives (+) facing up. Snap battery cover back on. 5. First Time Installation & Test Checklist: This section explains a few things you should know for proper operation and easier use of the ATOM system. Whenever transmitting commands (laser or IR) with the LRC, it must be pointed at and in the line of-sight of the module s sensors that you are sending signals to. BATTERY COVER Make sure there is a good ground throughout, starting at the luminaire ground and ending with the earth ground. Make sure, on the remote that the protective plastic is removed from between the batteries and contacts as shown in Section 3, "replacing batteries" or the remote will not work. Testing a DM or NDM 1. Turn off power to track. 2. Install module into track with luminaire attached (See Section 3 Installation of Modules to Lytespan Track Systems). Re-power Track. 3. Using the LRC, press and hold the Learn button for PROTECTIVE 2 seconds which turns on the Module s LED so it can PLASTIC BATTERIES be easily located. 4. Press and hold the Laser button and aim laser modules, select them in the same manner if they need to be programmed identically to the first module.) The module s LED(s) will blink at a 1/2 second rate when in program mode. The LRC s LED will also blink (every 1 second) to indicate the transmitter will be transmitting program IR commands when buttons are depressed. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 5. Press a SCENE button A B C D E F ON or OFF If the module responds to these buttons with changes in light levels, it s working. 6. Press the end e button to exit the program mode
7 Testing a TM 1. Turn off power to track. 2. Install modules into track with luminaire attached (See Section 3 Installation of Modules to Lytespan Track Systems). Install TM into track. Re-power Track. 3. Using the LRC, press and hold the Learn button for 2 seconds which turns on the TM s LED so it can be easily located. 4. Press and hold the Laser button and aim laser beam at the TM s receiver to select it and place it in program mode. The TM s LED(s) will blink at a 1/2 second rate when in program mode. The LRC s LED will also blink (every 1 second) to indicate the transmitter will be transmitting program IR commands when buttons are depressed. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 5. Point the handheld LRC transmitter in the general direction of the TM and press a SCENE button A B C D E F ON or OFF. If the module s respond to these buttons with changes in light levels, the TM is working. 6. Press the end e button to exit the program mode. 6. Programming ATOM (Basic) Quick Tips: Easily Locating Modules on Ceiling or Wall 1. The Modules LED s can be turn on so they can be located easily on the ceiling or wall: a) To have the LED(s) blink on, press the Learn button. b) To have the LED(s) stay on for 60 seconds, press and hold the Learn button for 2 seconds. NOTE: When using a TM, pointing the LRC at the TM and performing step 1a above will cause all of the Module s LED s on its address to blink on. Note: DM s and TM s have red LED s and NDM s have green LED s. This can be done anytime the Modules aren t in program mode. It is recommend to do this before programming so all Modules can be located easily and there is a target to aim the laser. Forcing A Fade: DM s will always fade into and out of a scene. The default fade rate for all fades is 3 seconds but can be set to as long as 30 minutes or as short as 1 1/2 seconds. If a scenes fade rate is long, you can press the Fade f button to force a fast fade into the scene. Programming Modules Programming a DM or NDM Creating Scenes with One or Multiple Modules modules, select them in the same manner if they need to be programmed identically to the first module.) The module s LED(s) will blink at a 1/2 second rate when in program mode. The LRC s LED will also blink (every 1 second) to indicate the transmitter will be transmitting program IR commands when buttons are depressed. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 2. Press a SCENE button to be programmed ( A B C D E F ON or OFF ). The module(s) will start to fade to the current scene level (the default fade rate for all scenes is 3 sec). NOTE: For the OFF Scene, only the fade rate can be changed, not the light level. NOTE: The NDM will switch to full light output and will not fade. 3. Press the LRC s up or down button s for the desired light level setting for the scene. If you only want to change the fade rate, skip this step. 4. To change the fade rate for the selected scene, press the Fade f button. Press the Fade f button again for a 1 1/2 sec fade or one of the TIME buttons ( sec., 5 or 30 min.). If you don t want to change the fade rate, skip this step. 5. Repeat steps 2 through 5 for all scenes you want to program. 6. To exit the program mode and SAVE the parameters you have just set, press the Learn button. To exit the program mode and CANCEL any parameters you just set, press the end e button. The selected module(s) LED(s) will stop blinking indicating that you are no longer in program mode. NOTE: If using a TM that is in the LRC s viewing angle, all modules that have the same address as the TM will respond to scene changes
8 Programming A System Quick Tips Globally Select Modules with TM The TM can be used to put all of the Modules with its same address into programming mode. This is for global changes while setting scenes. beam at the TM s receiver to select it and place it in program mode. The TM s LED(s) will blink at a 1/2 second rate when in program mode. The LRC s LED will also blink (every 1 second) to indicate the transmitter will be transmitting program IR commands when buttons are depressed. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 2. Press and hold the Fade f button for more than 3 seconds, causing the LED to blink rapidly and then after 3 seconds stay on. Release the Fade f button. The TM s LED will start to blink at a 1/2 second rate, delay for two seconds, then send a signal to all Modules on its address which will also start blinking at a 1/2 second rate, indicating that they are all in program mode. Now any scene can be changed or modified globally by following the program steps while pointing the LRC at the TM. Programming Basics with TM Creating Scenes With DM & NDM Units Using TM To create scenes with individual Modules using the TM, perform step 1 from the "Creating Scenes with One or Multiple Modules" section, selecting the individual Modules with the laser. When all Modules are selected, perform steps 2-6, pointing the LRC at the TM, which will communicate the commands to all the selected Modules in Program mode. To create scenes with all Modules at the same time using the TM, globally select all Modules using the Quick Tip above. When all Modules are selected, perform steps 2-6 from the "Creating Scenes with One or Multiple Modules" section, pointing the LRC at the TM, which will communicate the commands to all the Modules in program mode. Programming Effects with TM The Effects program requires a TM to synchronize all the DM s and NDM s in the system and to store the program. Creating Cycles The Cycle effect will transition from one scene to another through a selected sequence of scenes and will repeat the same scene sequence while activated. The TM has the capability of storing up to 6 Cycles. These are referred to as cycles A B C D E and F. Each Cycle consists of 1 to 10 steps. Each step consists of a pre-fade (Optional), a scene, and a delay (Optional). Cycles can be executed once and stop automatically (single cycle), or repeat (loop) until stopped by the user. NOTE: If more than one TM is going to be used to cycle, they must all be on different addresses (see page 18). If they will be cycling on different circuits using Lightolier Controls Compose Firewall, up to two cycles can be run at the same time. beam at the TM s receiver to select it and place it in program mode. The TM s LED(s) will blink at a 1/2 second rate when in program mode. The LRC s LED will also blink (every 1 second) to indicate the transmitter will be transmitting program IR commands when buttons are depressed. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 2. Press and hold the Cycle c button for more than 3 seconds (the TM s LED will blink rapidly and then after 3 seconds stay on). Release the Cycle c button. The TM s LED will indicate that it s in cycle program mode by turning on with short blinks every second. 3. Select the Cycle to be programmed by pressing a letter button ( A B C D E or F ). 4. Press the Begin b button to start the programming. The LED will blink repeatedly one short blink and a delay to indicate that it is waiting for a Fade Rate or a Scene to be entered. 5. To enter a Cycle sequence without entering fade rates and time delays (system will use the default fades and delays), simply press the Scene button in the desired sequence. Ex. ( A C ON D OFF B ).The Scenes selected will be transmitted to all Modules to show the scene effects. Advance to step To enter a Cycle sequence with fade rates and/or time delays follow steps 6a, 6b and 6c. a) To enter (or change) a Fade Rate, press the fade f button (for a 1 1/2 second fade) or f and one of the TIME buttons ( sec. 5 or 30 min.) for the desired Fade Rate. (If any of these buttons are pressed after each other, the last button pressed will be what is programmed). The LED will blink repeatedly one short blink and a delay to indicate that it is waiting for a Scene to be entered
9 (To use default or programmed Fade Rate skip this step and advance directly to step 6b). Advance to step 6b. b) Enter the desired Scene by pressing the SCENE button ( A B C D E F ON or OFF ). The Scene selected will be transmitted to all modules to show the Scenes effect. The LED will blink repeatedly two short blinks and a delay to indicate that it is waiting for a Time Delay, or that it is ready for the next Scene to be entered. (To use the default Time Delay, skip step 6c ). Advance to step 6c. c) To enter a Time Delay, press one of the TIME buttons ( sec. 5 or 30 min.). i) To accumulate the previous selected Time Delay, press the same TIME button up to 3 more times. (ex: 5 min., 5 min., 5 min., 5 min., will allow a 20 minute delay to be entered). ii) To select a different Time Delay and override your previous selection, press one of the TIME buttons ( sec. 5 or 30 min.) different than what was previously selected. For the next scene in the Cycle sequence, repeat steps 6a, 6b, 6c. A total of 10 Scenes can be entered into a Cycle program. NOTE: If an 11th Scene is attempted, the TM s LED will turn on with short off blinks every second to indicate that no more steps can be entered. Once the desired Cycle Scene sequence is completed, Advance to step Ending a Cycle Sequence can be done anytime during steps 5 or 6 and will end wherever the last command is entered. a) To exit the Cycle program mode, SAVE any parameters you have just set, and make the entered program execute once and then automatically stop, press the Learn button. b) To exit the Cycle program mode, SAVE any parameters you have just set, and make the entered program repeat (cycle) until stopped by the user, press the Cycle c button and then the Learn button. c) To exit the Cycle program mode and CANCEL any An example of a Cycle Sequence using all of the above combinations is as follows: Pgm Step I: Fade in 1.5 seconds to Scene "A", then delay 7 seconds. Pgm Step II: Fade in 15 seconds to Scene "B" (no delay after Scene "B" is reached). Pgm Step III: Fade to Scene "C" (using the each Modules individual default fades), and delay 6 seconds. Pgm Step IV: Fade in 3 seconds to "OFF", (no delay after "OFF" is reached). Pgm Step V: Repeat (cycle) Program Steps I-IV. To enter the above Cycle using the LRC, perform the following: beam at the TM s receiver until it starts to blink at a 1/2 second rate. 2. Press and hold the Cycle c button for more than 3 seconds. 3. Select the Cycle to be programmed by pressing a letter button ( A B C D E or F ). 4. Press the Begin b button to start the programming. 5. Press the fade f button, the A button, and then the 7 sec button to program Step I. 6. Press the fade f button, the 15 sec. button, and then the B button to program Step II. 7. Press the C button, and then the 3 sec. button (twice) to program Step III. 8. Press the fade f button, the 3 sec. button, and then the OFF button to program Step IV. 9. Press the Cycle c button. 10. Press the Learn button. Clearing Cycles NOTE: Performing this command will overwrite any cycle you have programmed. Make sure your not overwriting anything you will need. To clear a cycle, perform steps 1 to 4, then step 7a from the "Creating Cycles" section. This will put no information on the cycle, clearing anything previously entered. 7. Programming ATOM (Advanced Features) Enabling/Disabling the IR (DM, NDM, & TM) parameters you just set, press the end e button. The IR receiver can be Enabled or Disabled. The Factory The selected modules LED s will stop blinking Default for the module s IR (InfraRed control) is Disabled indicating that you are not in program mode any and the TM is Enabled. This prevents individual module s more. from responding to IR commands when not in Program Mode (which is only activated by the laser) and only reacting to commands sent to the TM. When a module s IR is Enabled, it will respond to IR commands at all times (not just in its Program Mode). 16 modules, select them in the same manner if they need to be programmed identically to the first module.) 17
10 The module s LED(s) will blink at a 1/2 second rate when in program mode. The LRC s LED will also blink(every 1 second) to indicate the transmitter will be transmitting program IR commands when buttons are depressed. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 2. Press and hold the Begin b button for greater than 3 seconds (the module s LED(s) will blink rapidly and then after 3 seconds stay on). Release the Begin b button. The module s LED(s) will blink at a 1/4 second rate. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 3. To Enable the IR, press the ON button. To Disable the IR, press the OFF button. 4. To exit the program mode and SAVE the parameters you have just set, press the Learn button. To exit the program mode and CANCEL any parameters you just set, press the end e button. The selected modules) LED(s) will stop blinking indicating that you are no longer in program mode. Address Programming for DM, NDM & TM Addressing allows you to set and address individual modules to run several completely separate ATOM systems on the same track. The Factory Default for the DM, NDM, & TM s Address is C1. This allows all units to communicate "out of the box" with out any addressing. A TM will only operate with a DM, NDM, or WRC that match its same address. All modules,tm s, & WRC s have the same address when shipped from the factory. If a change in address is desired: modules, select them in the same manner if they need to be programmed identically to the first module.) The module s LED(s) will blink at a 1/2 second rate when in program mode. The LRC s LED will also blink (every 1 second) to indicate the transmitter will be transmitting program IR commands when buttons are depressed. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 2. Press and hold the Begin b button for greater than 3 seconds (the module s LED(s) will blink rapidly and then after 3 seconds stay on). Release the Begin b button. The module s LED(s) will blink at a 1/4 second rate. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 3. If you know what address you want to program a DM, NDM, or TM, press the following with the LRC: a) A for address C1 House "C", Unit "1" b) B for address C2 House "C", Unit "2" c) C for address C3 House "C", Unit "3" d) D for address C4 House "C", Unit "4" e) E for address C5 House "C", Unit "5" f) F for address C6 House "C", Unit "6" Advance to step 4 If you want to program a, DM or NDM s address to match the address of a TM, WRC, or a Compose CP Master, perform the following steps: a) To program the modules address to match a TM s address, aim the LRC in the direction of the module and press any of the SCENE buttons ( A B C D E or F ) (this puts the modules in address search mode which looks for another units address) and wait two seconds. Aim the LRC in the direction of the TM and press the Cycle c button. Advance to step 4. b) To program the modules address to match a WRC or Compose CP Master Unit s address, aim the LRC in the direction of the module and press any of the SCENE buttons ( A B C D E or F ) (this puts the modules in address search mode which looks for another units address) and wait two seconds. Press any SCENE button (A, B, C, D, ON, or OFF) on the WRC or CP Master Unit. Advance to step 4. If you want to program a TM s address to match the address of a WRC or Compose CP Master. Point the LRC at the TM and press any of the SCENE buttons ( A B C D E or F ) (this puts the modules in address search mode which looks for another units address) and wait two seconds. Press any SCENE button (A, B, C, D, ON, or OFF) on the WRC or CP Master Unit. Advance to step To exit the program mode and SAVE the parameters you have just set, press the Learn button. To exit the program mode and CANCEL any parameters you just set, press the end e button. The selected modules) LED(s) will stop blinking indicating that you are no longer in program mode. NOTE: To do a check to see what modules are on the TM s address, see Globally Select Modules with TM from section 6. All of the modules that go into program mode are on the same address as the TM. Address Programming for a WRC 1. On the WRC, press and hold the B and E buttons for 3 seconds. The Cycle button will blink and the house address will be displayed on the remaining buttons. 2. Press the B button multiple times until only the End button is lit. You are now at House A. 3. Press the A button to select House B. 4. Press the A button again to select House C. Continue this sequence until the desired House is selected. 5. Press the Cycle button. You will now select the unit number. 6. Press the B button until only the End button is lit (This is done the same way as in step 2). You are now at Unit Press the A button to select Unit Press the A button again to select Unit 2. Continue this sequence until the desired unit is selected. 9. Press the Cycle button to exit and save the address settings
11 Enabling/Disabling the Verify Command (TM) NOTE: This command is only used if using a Lightolier Controls Compose CM Master. modules, select them in the same manner if they need to be programmed identically to the first module.) The module s LED(s) will blink at a 1/2 second rate when in program mode. The LRC s LED will also blink (every 1 second) to indicate the transmitter will be transmitting program IR commands when buttons are depressed. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving). 2. Press and hold the Begin b button for greater than 3 seconds (the module s LED(s) will blink rapidly and then after 3 seconds stay on). Release the Begin b button. The module s LED(s) will blink at a 1/4 second rate. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 3. To Enable Verify, press the button. To Disable Verify, press the button. 4. To exit the program mode and SAVE the parameters you have just set, press the Learn button. To exit the program mode and CANCEL any parameters you just set, press the end e button. The selected modules) LED(s) will stop blinking indicating that you are no longer in program mode. 8. Operation of the ATOM System Operating Commands For all of the commands listed here, there are several different ways to communicate them to the modules. They can be received from the LCR, TM, or WMC. If there are selected modules that need to be set, the LRC must be used. If multiple modules need to change all at once, you could (1) Individually select all of the modules with the LRC, (2) set them all at once with a TM and communicate to it with either the LRC or WMC, or (3) set them all at once (without using a TM) with just a WMC. NOTE: Whenever the power is turned off, the Modules and TMs will keep their individual settings. If in a Scene when the power is turned off, they will automatically fade back to the scene they where in when power returns. If running a cycle when power is turned off, they will automatically start that same cycle over again from the beginning step when power returns. Turning On & Off (DM, NDM, & TM) Using the LRC: NOTE: If using a TM and would like to communicate with all modules (with it s same address) at once, skip step 1 and begin on step 2. modules, select them in the same manner if they need to be programmed identically to the first module.) The module s LED(s) will blink at a 1/2 second rate when in program mode. The LRC s LED will also blink (every 1 second) to indicate the transmitter will be transmitting program IR commands when buttons are depressed. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 2. Press either the ON or OFF button to turn the module(s) on or off. 3. Press the end e button. The selected module s LED(s) will stop blinking indicating that you are no longer in program mode. Using the WRC: 1. Press the END button to put all modules that have the same address as the WRC into the OFF Scene. NOTE: The WRC cannot transmit the ON scene. Dimming (DM & TM) Using the LRC: NOTE: If using a TM and would like to communicate with all modules (with it s same address) at once, skip step 1 and begin on step 2. modules, select them in the same manner if they need to be programmed identically to the first module.) The module s LED(s) will blink at a 1/2 second rate when in program mode. The LRC s LED will also blink (every 1 second) to indicate the transmitter will be transmitting program IR commands when buttons are depressed. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 2. Press the LRC s up or down button s for the desired light level setting. 3. Press the end e button. The selected module s LED(s) will stop blinking indicating that you are no longer in program mode. Running a Scene (DM, NDM, & TM) Using the LRC: NOTE: If using a TM and would like to communicate with all modules (with it s same address) at once, skip step 1 and begin on step
12 modules, select them in the same manner if they need to be programmed identically to the first module.) The module s LED(s) will blink at a 1/2 second rate when in program mode. transmitting program IR commands when buttons are depressed. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 2. Press a SCENE button to be programmed ( A B C D E F ON or OFF ). (When using a TM that s in the LRC s viewing angle modules with it s same address, including those that aren t in programming mode, will respond to scene changes so all modules would change to the scene selected.) The module(s) will start to fade to the current scene level (the default fade rate for all scenes is 3 sec). NOTE: The NDM will switch to full light output and will not fade. 3. Press the end e button. The selected module s LED(s) will stop blinking indicating that you are no longer in program mode. Using the WRC: 1. Press a SCENE button (A through F). (All of the modules that have the same address as the WMC will respond to scene changes). The module(s) will start to fade to the current scene level (the default fade rate for all scenes is 3 sec). NOTE: Pressing the END button will transmit the OFF scene. Pre-Fading a Scene (DM & TM) Using the LRC: NOTE: If using a TM and would like to communicate with all modules (with it s same address) at once, skip step 1 and begin on step 2. modules, select them in the same manner if they need to be programmed identically to the first module.) The module s LED(s) will blink at a 1/2 second rate when in program mode. The LRC s LED will also blink (every 1 second) to indicate the transmitter will be transmitting program IR commands when buttons are depressed. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 2. Press the Fade f button (1.5 sec) or any of the TIME buttons ( sec. 5 or 30 min.). 3. Within 4 seconds of Step 3, press the desired SCENE button ( A B C D E F ON or OFF ). All units will fade to their scene levels at the fade rate set in Step 2. NOTE: If the present fade rate is long, you can press the Fade f button to force a fast fade into the scene. This will force a 1 1/2 sec fade on the present scene. Starting a Pre-Programmed Cycle (TM) Using the LRC: 1. Press the Cycle c button. 2. Press the desired Cycle button ( A B C D E or F ). If this step is skipped, the last cycle that was run will be selected. 3. Press the Begin b button. The cycle will start its programmed step 1. The TM s LED will turn on with short blinks every second to indicate that it is in Cycle Mode (controlling the TM). 4. To skip a running cycle one step (for testing purposes), press the Fade f button. All Modules will fast fade to their scene and after 2 seconds the TM will start executing its next step. Using the WRC: 1. Press the CYCLE button. The button s LED will turn on for 4 seconds waiting for a command. 2. While the CYCLE button is still turned on: a) Press the CYCLE button again to start the cycle that was last run. b) Press the desired cycle button (A through F) to start its cycle. While a cycle is running, the CYCLE button s LED will remain on and the cycle being executed button (A through F) will blink at a 1 second rate. Halting a Running Cycle (TM) Using the LRC: a) Press any SCENE button ( A B C D E F ON or OFF ). The cycle will stop and all modules will advance to the scene pressed at their individual fade rates. b) Press the End e button. All modules will halt any fading and the cycle will stop. Using the WRC: a) Press the CYCLE button to interrupt any cycle program running and transmit the cycle command. The button s LED will turn on for 4 seconds and then turn off. b) Press any scene button (A through F) to interrupt any cycle program running and transmit the scene command. All modules will change to that selected scene and their LED s will turn on. c) Press the END button to interrupt any cycle program presently running and stop any modules fading. All LED s will turn off
13 Factory Defaults Factory Defaults for the DM Address: C1 (House "C", Unit "1") IR: Disabled (When not in Program Mode) Present Scene: ON Scene Present Level: 100% OFF: Level 0% - Fade 3 Sec ON Scene: Level 100% - Fade 3 Sec A Scene: Level 86% - Fade 3 Sec B Scene: Level 72% - Fade 3 Sec C Scene: Level 58% - Fade 3 Sec D Scene: Level 44% - Fade 3 Sec E Scene: Level 30% - Fade 3 Sec F Scene: Level 16% - Fade 3 Sec G Scene: Level 13% - Fade 3 Sec H Scene: Level 10% - Fade 3 Sec I Scene: Level 7% - Fade 3 Sec J Scene: Level 5% - Fade 3 Sec K Scene: Level 3% - Fade 3 Sec L Scene: Level 1% (Night Light) - Fade 3 Sec Scenes are only available when using a Lightolier Controls Compose 8 Button Wall Master. Consult factory for more information and programming instructions. Factory Defaults for the NDM Address: C1 (House "C", Unit "1") IR: Disabled (When not in Program Mode) Present Scene: ON Scene Present Level: 100% OFF: Level 0% - Fade 0 Sec ON Scene: Level 100% - Fade 0 Sec A-L Scene: Level 100% - Fade 0 Sec Factory Defaults for the TM Address: C1 (House "C", Unit "1") IR: Enabled Present Scene: ON Scene Cycle A Program: Scenes A - B - C - D. All have 1.5 second fade rates and will switch scenes every 3 seconds Cycle B Program: Cleared Cycle C Program: Cleared Cycle D Program: Cleared Cycle E Program: Cleared Cycle F Program: Cleared Verify: Disabled Restoring Factory Defaults CAUTION: When setting modules back to Factory Defaults, you will be erasing ALL of the programming that has been performed. Make sure you won t be loosing anything important before proceeding. modules, select them in the same manner if they need to be programmed identically to the first module.) The module s LED(s) will blink at a 1/2 second rate when in program mode. The LRC s LED will also blink (every 1 second) to indicate the transmitter will be transmitting program IR commands when but tons are depressed. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 2. Press and hold the Begin b button for greater than 3 seconds (the module s LED(s) will blink rapidly and then after 3 seconds stay on). Release the Begin b button. The module s LED(s) will blink at a 1/4 second rate. (After 60 seconds of inactivity, the module(s) will exit the program mode without saving.) 3. Press and hold the Laser button and aim laser beam at the module(s) you are programming. This will reinitialize the module to its factory defaults. NOTE: Any other sequence will prevent the Factory Defaults from being set. 9. Troubleshooting When I point the LRC at the TM and try to raise or lower the light level of all of the modules, nothing happens. Check the LED on the LRC. If it is blinking, this means you re in select/program mode. In order to raise or lower modules with a TM in this mode, you must individually select the modules you want to change or if you want all modules to raise or lower at the same time, you must exit this mode first by pressing the end e button. When dimming, the module will continue to dim even after I ve stopped pressing the remote buttons. Because of the delay in receiving IR commands, the desired light level may have been missed. Therefore release the up or down button s prior to the desired light level. Make sure there is a good ground throughout, starting at the luminaire ground and ending with the earth ground
14 Remote does not work: Check that you are within 25 feet of the module you are trying to transfer commands to and in a direct line-of-sight. The batteries may need replacement or the Protective plastic may need to be removed (first time use only). See "Replacing Batteries" in section 4. The track luminaires are going on and off without touching any buttons anywhere to initiate it: There could be a cycle running. To know if a cycle is running, check the TM. If its LED is blinking, a cycle is most-likely running. If using the WRC, the CYCLE button s LED will be lit and the button s LED or the cycle that s running (A through F) will be blinking. Is there an In-Line Filter on the circuit? It is recommended for each track circuit with an ATOM installation. The In-Line Filter reduces unwanted electrical noise on track circuit. The modules could be in the process of a very long fade. To advance a fade, hit the fade f button. 10. Appendix Addressing: Allows you to set and address individual modules to run several completely separate ATOM systems on the same track. Setting an address will also allow you to communicate with the Lightolier Controls Compose PLC line. Cycle: The modules can cycle trough scenes with programmed fade rates and time delays in a continuous loop or a single cycle. This function requires a Track Master Module. Cycle Program Mode: Activated when the laser on the LRC is pointed at a receiver on a TM, in this mode the TM can receive IR commands to set scenes to communicate with all of the modules with it s same address. Fade Rate: The time transition between scenes can be programmed into each module. The fade rate is this transition. Modules are pre-programmed with a 3 sec fade rate between scenes that may be extended to 30 minutes or reduced to 1.5 seconds. Module: Used to denote either a DM, NDM, or both. Program Mode: Activated when the laser on the LRC is pointed at a receiver on a module, in this mode the module can receive IR commands to change light intensities, fades, and scenes. Scene: Lighting effects and light levels can be saved in each module for use at any time. Each group of saved settings is called a scene. Each module has 6 programmable scenes (A through F) and On and Off scenes. System: A group of more than one DM and/or NDM, used with a TM and/or WMC to make up a "system" that talks to itself. Time Delay: In a cycle program, the time a scene will run. The time delay will start once the scene is done fading in. Right after the time delay is done, the fade to the next scene begins
15 IMPORTANT: Read and retain these instructions for future use. DO NOT THROW AWAY! A Genlyte Company 631 Airport Road, Fall River, MA A Genlyte Company Petal Street, Dallas, TX For technical/sales assistance call: Made in U.S.A. Lightolier IS: ATOM
Luminaire installation box Surface-mounted box Ceiling installation box
-Smart PTM Ambient light sensor and motion detector for constant lighting control uminaire installation box Surface-mounted box Ceiling installation box Overview: -SMART PTM i is an ambient light sensor,
More informationAppendix Lightolier Compose System
Appendix Lightolier Compose System The Lightolier Compose system has been designated a legacy feature and support is normally unavailable. Open the HCA Properties dialog and choose the legacy tab to enable
More informationEasyAir Philips Field Apps User Manual. May 2018
EasyAir Philips Field Apps User Manual May 2018 Content Introduction to this manual 3 Download App 4 Phone requirements 4 User Registration 5 Sign in 6 Philips Field Apps 7 EasyAir NFC 8 Features overview
More informationAutomatic Transfer Switch Control PLC Operator s Manual
MTS Power Products MIAMI FL 33142 ATS-22AG Automatic Transfer Switch Control PLC Operator s Manual Dedicated Single Phase Transfer Switch ATS-22AG Automatic Transfer Switch INTRODUCTION 1.1 Preliminary
More informationScoreboard Operator s Instructions MPCX SCD / DGT / Pitch Time Control
Scoreboard Operator s Instructions MPCX SCD / DGT / Pitch Time Control Since 1934 Retain this manual in your permanent files Rev. 2/3/2012 135-0136 These Instructions are for the Following Models: LED
More information24 CHANNEL DIMMER CONSOLE USER MANUAL
PAGE 1 wdmlighting.com CHANNEL DIMMER CONSOLE USER MANUAL WDM LIGHTING 3 OAK LAWN AVE., STE. 1, DALLAS, TX 7519 Improvement and changes to specifications, design and this manual, may be made at any time
More informationGreenParking. Commissioning guide. GreenParking
GreenParking GreenParking Page Table of Contents Introduction....4. GreenParking...4. Working principle...4.3 Intended use...4.4 About this commissioning guide...4.5 Warnings.............................................................
More informationINSTALLATION AND OPERATION MANUAL
Lightolier 8-8A0 /8/0 : AM Page IMPORTANT: RETAIN THESE INSTRUCTIONS FOR THE END USER. DO NOT DISCARD. INSTALLATION AND OPERATION MANUAL A B C D E F G H MULTISET PRO - PRE-WIRED DIMMING CABINET MDC COMPATIBLE
More informationAmerican DJ. Show Designer. Software Revision 2.08
American DJ Show Designer Software Revision 2.08 American DJ 4295 Charter Street Los Angeles, CA 90058 USA E-mail: support@ameriandj.com Web: www.americandj.com OVERVIEW Show Designer is a new lighting
More informationSTX Stairs lighting controller.
Stairs lighting controller STX-1795 The STX-1795 controller serves for a dynamic control of the lighting of stairs. The lighting is switched on for consecutive steps, upwards or downwards, depending on
More informationTITLE BOX PAGE ONLY. DO NOT MAKE FILM DO NOT PRINT
REV DESCRIPTION INT: REV. DATE APPROVED 1 ECO# CO1790 MJS 9/27/06 CG 2 ECO# 02412 DR 10/3/07 CG 3 ECO# 03170 MJS TITLE BOX PAGE ONLY. DO NOT MAKE FILM DO NOT PRINT MATERIAL: White 16lb (60g/m sq), uncoated,
More informationSpacer System dimmers and switches
2.94 in (75 mm) 4.69 in (119 mm).30 in (7.6 mm) profile Product family features True multi-location dimming from every location Use the IR (infrared) remote control to adjust lights from anywhere in the
More informationIntegrated 13-Scene Preset Dimming System
INSTALLATION AND OPERATIONS MANUAL Important: Retain These Instructions For The End User. DO NOT THROW AWAY! Integrated 13-Scene Preset Dimming System Classic Series Ellipse Series FOR USE WITH MODELS:
More informationRain+Birdt. Landscape Irrigation & Maintenance Remote System. Quick Start Guide 4.00 F G H K 9X. c n. System Components
Rain+Birdt Landscape Irrigation & Maintenance Remote System Quick Start Guide 4.00 D System Components A Transmitter (TX) B Receiver (RX) C Quick Connect (QC) 6-Pin Quick Connect (QC) for use with ESP-Modular
More informationSPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20
SPX-5600 Series Operations Manual Suprex Reader Extender - RF Wireless Interface SPX-5600MAN Page 1 of 20 SPX-5600 Series: Cypress Suprex SPX-5600 Series This manual covers the operation and setup of the
More informationSample BD Tech Concepts LLC
XYZ Corp. Fry Controller FC-1234 Software Test Procedure Copyright 2014 Brian Dunn BD Tech Concepts LLC Last Modified: 00/00/0000 Version Tested: Date Tested: Technician: Results: 1 FC-1234 SW Test Proc.
More informationRT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz
RT505TX T RT505 T505TX TX RT505TX RT505TX RT505TX 5TX Programmable Room o Thermostat RXBC605 RXRT505 RXWBC605 RXST625 RXVBC605 The RT505TX can be used with any of these receivers 868MHz RT505TX RT505TX
More informationScoreboard Operator s Instructions MPCX Volleyball Control
Scoreboard Operator s Instructions MPCX Volleyball Control Since 1934 Retain this manual in your permanent files Rev. 2/3/2012 135-0137 These Instructions are for the Following Models: LED models: Incandescent
More informationUSER'S MANUAL. ADJ R Junostraat EW Kerkrade
USER'S MANUAL ADJ R Junostraat EW Kerkrade www.adj.com Improvement and changes to specifications, design and this manual, may be made at any time without prior notice. All Rights Reserved Contents Features
More informationMaxLite LED Wall Packs (Cutoff & Standard)
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationTebis application software
Tebis application software LED projector with quicklink radio infrared detector Electrical / Mechanical characteristics: see product user manual Product reference Product designation Application software
More informationWDP02 Wireless FHD Kit User Manual
WDP02 Wireless FHD Kit User Manual Copyright Copyright 2015 by BenQ Corporation. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system
More informationTebis TX100 Configurator
5 Tebis TX100 Configurator quicklink Radio input products Electrical / Mechanical characteristics: see product user's instructions Product reference Product designation TX100 version TP device RF device
More informationMSC+ Controller. Operation Manual
MSC+ Controller Operation Manual Contents Introduction... 1 Controls and Indicators...1 Programming the Controller... 3 Definitions...3 Programming Checklist...3 Power-Up the Controller...4 Clock Status
More informationRemote Control. degraded, causing unreliable operation. The recommended effective distance for remote operation is about 16 feet (5 meters).
Media Streaming Sound Bar RTS736W User Manual Remote Control using the remote control Point the remote control at the REMOTE SENSOR located on the unit (see Front Panel illustration for precise location).
More informationDimming actuators GDA-4K KNX GDA-8K KNX
Dimming actuators GDA-4K KNX GDA-8K KNX GDA-4K KNX 108394 GDA-8K KNX 108395 Updated: May-17 (Subject to changes) Page 1 of 67 Contents 1 FUNCTIONAL CHARACTERISTICS... 4 1.1 OPERATION... 5 2 TECHNICAL DATA...
More informationTebis application software
Tebis application software Input products / ON / OFF output / RF dimmer Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF device WYC42xQ
More informationRA-RS232, RB-RS232. Setup and Installation Guide Addendum For RadioRA RS232 Interface
RA-RS232, RB-RS232 Setup and Installation Guide Addendum For RadioRA RS232 Interface A Comprehensive Step-by-Step Guide for Programming and Operating the Lutron RadioRA RS232 Interface Note: Please leave
More informationSMART Blue Smart Switch
SMART Blue Smart Switch SMART Switch The feature SMART Switch makes it possible to use ordinary wall switches as dimmers or for retrieving scenes set up before. The SMART Switch can be configured by the
More informationWireless SMART1+ Remote Operating Instructions. P/N Rev. A
Wireless SMART1+ Remote Operating Instructions P/N 1123159 Rev. A Wireless SMART1+ Components P/N 1123159 Rev.A 1 2 Item Part # Description 1. 1123160 SMART1+ Replacement Transmitter (Agriculture/Grain
More informationUser s Guide. Dimensions 4000 Series Control System. Topics at a Glance
User s Guide Dimensions 4000 Series Control System Topics at a Glance Installation...See Installation Guide Quick Start Configuration...11 User Interface...8 Initial Setup...19 Scheduling...63 Scene Recording...54
More information192 Channel DMX Controller
DM-X 92 Channel DMX Controller USER MANUAL 54. 9UK Vers ion. D M X 5 2 C O N T R O L L E R S E R I E S Content. Before you begin. What is included.......2 Unpacking instructions....3 Safety instructions...
More informationINSTALLATION AND OPERATION MANUAL
INTELLISIGHT OCCUPANCY SENSOR & RELAY PACKS INSTALLATION AND MANUAL IMPORTANT: RETAIN THESE INSTRUCTIONS FOR THE END USER. DO NOT DISCARD. CEILING OCCUPANCY SENSOR ITSCS ITSCSHB RELAY PACK ITSRP1U ITSRP2U
More informationLabel Applicator HERMA 400
Label Applicator HERMA 400 Info GB V6.0 / 30.3.07 [ Facts & Data ] R Constructional variant Right-hand or left-hand version, always flexible to use L Power supply / Line voltage Max. power consumption
More informationTechni-Lux. COMMANDER 24&48 24&48 Ch DMX Controllers USER'S MANUAL. Please read before use V1.1
Techni-Lux COMMANDER & & Ch DMX Controllers USER'S MANUAL Please read before use V1.1 COMMANDER & & Ch DMX Controllers Improvement and changes to specifications, design and this manual, may be made at
More informationEnglish. Light Operator 24 USER'S MANUAL. Please read before use
English Light Operator USER'S MANUAL Please read before use Contents Light Operator Improvement and changes to specifications, design and this manual, may be may at any time without prior notice. All rights
More informationTHE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL
THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL INTRODUCTION The Gemini 5200 is another unit in a multi-purpose series of industrial control products that are field-programmable to solve multiple
More informationReceiver Description and Installation
Receiver Front Panel Smart Card Door Behind this door is a slot for a future smart card. No smart card is included with this receiver. Arrow Buttons Use the ARROW buttons to change channels on the nearby
More informationA digital version of this document is available to download and submit online at ADDRESS POST CODE
CHECK LIST i A digital version of this document is available to download and submit online at www.thorlux.com/commissioning To secure your preferred commissioning date please complete this form and email
More informationSTAGE 2412 DMX 24 CHANNELS DMX CONSOLE FOR CONVENTIONAL LIGHTING
English STAGE 1 DMX User Manual Rev. 11 STAGE 1 DMX CHANNELS DMX CONSOLE FOR CONVENTIONAL LIGHTING This symbol on the product or on its packaging indicates that this product shall not be trated as household
More information2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2
2 CHANNEL RECEIVER RECTSHIVE915-DX Please read this manual carefully before installing the product. 1 DESCRIPTION Receiver Rolling Code, 2 channels with dry contact relay output 20A a 12 Vdc. Programming
More informationTri-level Control HF Sensor
Daylight Monitoring TM Ambient daylight threshold oop in oop out Tri-level Control HF Sensor HC403VRC-KD HC404VRC-KD Detached Version with Daylight Monitoring and Remote Control Applications Occupancy
More informationSample BD Tech Concepts LLC
XYZ Corp. Fry Controller FC-1234 Operating Specification Copyright 2014 Brian Dunn BD Tech Concepts LLC Contents Last Modified: 00/00/0000 Introduction 2 Interface 3 Idle 5 Cooking Cycle 5 Displaying and
More informationSoftswitch128TM. SwitchingSystem. Setup and Maintenance Guide
Softswitch128TM SwitchingSystem TM R Setup and Maintenance Guide Believeitornot,thisissupposed to look likeadictionary! Thisiconwascreated by BrentM.Nye,July 6,1995. Believeitornot,thisissupposed to look
More informationUser Guide. Centrex Recording Interface
User Guide Centrex Recording Interface Table of Contents Introduction... 2 The Meridian Business Set... 3 Key Numbering Plan (18 button add-on)... 4 Key Numbering Plan (36 button add-on)... 5 Key Numbering
More informationPREPROGRAMMED FOR YOUR SET-TOP BOX
New Knoxville Telephone NKTELCO, Inc. Goldstar Communications 301 W. South Street PO Box 219 New Knoxville, OH 45871 PREPROGRAMMED FOR YOUR SET-TOP BOX ADB Remote Functions 1 New Knoxville Telephone 301
More informationK9123, K9134, K9135 Remote Programming Instructions and Specifications
K9123, K9134, K9135 Remote Programming Instructions and Specifications 12 Volt Signal Ground Signal Plug Door Push & Hold K9123 K9134 K9135 Before pairing the receiver to the remotes, the receiver must
More informationShow Designer 3. Software Revision 1.15
Show Designer 3 Software Revision 1.15 OVERVIEW... 1 REAR PANEL CONNECTIONS... 1 TOP PANEL... 2 MENU AND SETUP FUNCTIONS... 3 CHOOSE FIXTURES... 3 PATCH FIXTURES... 3 PATCH CONVENTIONAL DIMMERS... 4 COPY
More informationSimply clever! The digital DIN-rail time switches by Grässlin
Simply clever! The digital DIN-rail time switches by Grässlin talento pro Trends and developments on the market. Maximum energy efficiency at low efforts In a saturated fast-moving market, the trend towards
More informationCommander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L
Commander 384 w w w. p r o l i g h t. c o. u k U S E R M A N U A L 1, Before you begin 1.1: Safety warnings...2 3 1.2: What is included...4 1.3: Unpacking instructions...4 2, Introduction 2.1: Features...4
More informationSensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.
Sensor module Ref.No.: SM 1608 V03 Safety instructions Caution! Electrical devices may only be installed and fitted by electrically skilled persons. Non-compliance with the installation information could
More information8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )
SMARTSCAN 8000 PLUS LIGHT CURTAIN 1 Unpacking 8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/0160306 CD206B160306 ) Remove all packaging material and retain it Locate and keep the delivery
More informationFD Trinitron Colour Television
R 4-205-569-32(1) FD Trinitron Television Instruction Manual GB KV-14LM1U 2000 by Sony Corporation NOTICE FOR CUSTOMERS IN THE UNITED KINGDOM A moulded plug complying with BS1363 is fitted to this equipment
More informationIntegrated Remote Commander
3-244-192-12 (1) Integrated Remote Commander Operating Instructions RM-VL1000 2002 Sony Corporation WARNING To prevent fire or shock hazard, do not expose the unit to rain or moisture. To avoid electrical
More informationHL32D2A. HL32D2A Page 1 of 13
This document provide two levels of support; customer advice provides information that meant to be shared with the customer explaining possible operation issues that may be creating problems. Service assistance
More informationDimming actuators of the FIX series DM 4-2 T, DM 8-2 T
Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T DM 4-2 T 4940280 DM 8-2 T 4940285 Updated: Jun-16 (Subject to change) Page 1 of 70 Contents 1 FUNCTIONAL CHARACTERISTICS... 4 1.1 OPERATION... 5 2
More informationLCD VALUE SERIES (32 inches)
LCD VALUE SERIES (32 inches) http://www.orionimages.com All contents of this document may change without prior notice, and actual product appearance may differ from that depicted herein 1. SAFETY INSTRUCTION
More informationOrbit Marine LED Light with 24 hour Ramp Timer Pro LED Controller
Quick Installation Guide Orbit Marine LED Light with 24 hour Ramp Timer Pro LED Controller What s included: 1 - Orbit Marine LED light fixture with dual actinic/dual daylight LEDs with adjustable docking
More informationTELEVISION. Star Plans. Interactive Guide and DVR (Digital Video Recorder) Manual ARVIG arvig.net
TELEVISION Star Plans Interactive Guide and DVR (Digital Video Recorder) Manual 888.99.ARVIG arvig.net TABLE OF CONTENTS DVR Remote Control Button Features...3 Arvig Digital TV i-guide Quick Reference
More informationDMX-LINK QUICK OPERATION
DMX-LINK QUICK OPERATION RESETTING THE CURRENT PATCH TO A ONE-TO-ONE OR ZERO PATCH The current Patch List may be initialised as a One-to-One or Zero patch as follows: 1. Ensure the Record LED is on. If
More informationInteraction of Infrared Controls And Fluorescent Lamp/Ballast Systems In Educational Facilities
LSD 6-1999 A NEMA Lighting Systems Division Document Interaction of Infrared Controls And Fluorescent Lamp/Ballast Systems In Educational Facilities Prepared by Lamp Section Ballast Section National Electrical
More information3214NXT. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference
3214NXT Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents Job Specification Sheet 3 Timer Operation 4 System Operation in Service 6 Flow in a Four-Unit
More informationPart names (continued) Remote control
Introduction Part names (continued) Remote control (1) STANDBY ( 25) (1) (2) ON ( 25) (3) (3) ID - 1 / 2 / 3 / 4 s ( 18) (4) (4) COMPUTER 1 ( 27) (7) (5) COMPUTER 2 * (8) (6) COMPUTER 3 * (10) (13) (7)
More informationEN Wireless programmable thermostat
EN Wireless programmable thermostat Contents 1. Installation... 31 2. Description... 32 EN 3. Wireless association... 33 4. Configuration... 34 CF01 - Correcting the temperature measured... 34 CF02 - Temperature
More information2002 Martin Professional A/S, Denmark.
Freekie user manual 2002 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Martin Professional
More informationOWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701
OWNER S MANUAL PW MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701 ANY CHANGES OR MODIFICATIONS IN CONSTRUCTION OF THIS UNIT DEVICE WHICH IS NOT APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIACE COULD VOID
More informationOPERATION AND MAINTENANCE
BAS MS/TP Enabled OPERATION AND MAINTENANCE An Company Contents Powering Up For The First Time... 3 Setting MSTP Communication Parameters... 4 Changing the MSTP Address... 4 Changing the BACNET ID... 5
More informationEnvironmental Conditions, page 2-1 Site-Specific Conditions, page 2-3 Physical Interfaces (I/O Ports), page 2-4 Internal LEDs, page 2-8
2 CHAPTER Revised November 24, 2010 Environmental Conditions, page 2-1 Site-Specific Conditions, page 2-3 Physical Interfaces (I/O Ports), page 2-4 Internal LEDs, page 2-8 DMP 4305G DMP 4310G DMP 4400G
More informationModel 1476-C SuperQuad HR
Model 1476-C SuperQuad HR Installation and Operating Instructions Table of Contents Page Table of Content... 2 System Description... 3 Features... 3 Installation... 4 Internal Setups... 4 Connections...
More informationVLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216
Light Program Controller VLC-3 USER'S MANUAL +50,1 +50,1 1 : $ ' 2 7. 6 8 ' 5, 7 6 6. $ ( 3 352*5$0 0,16(& )81&7,216 6(77,1*6 & 8 5 5 ( 1 7 3 ( 5, 2 ' M 890-00189 rev. 04 K 895-00406 rev. 00 GENERAL...
More information99 Washington Street Melrose, MA Fax TestEquipmentDepot.com OPERATION MANUAL. The Best Thing on Cable
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com OPERATION MANUAL The Best Thing on Cable Table of Contents INDEX I General Information Introduction... 3 Features: RSVP 2
More informationHardware Setup. HP Dual TV Tuner/Digital Video Recorder. Document Part Number:
Hardware Setup HP Dual TV Tuner/Digital Video Recorder Document Part Number: 374787-001 November 2004 This guide provides steps to help you set up your HP Dual TV Tuner/Digital Video Recorder hardware
More informationVNS2200 Amplifier & Controller Installation Guide
VNS2200 Amplifier & Controller Installation Guide VNS2200 Amplifier & Controller Installation 1. Determine the installation location for the VNS2200 device. Consider the following when determining the
More informationLaw Enforcement Audio&Video Recorder. User manual Ford Road, Suite # 110, Dallas, TX Tel: Fax:
Law Enforcement Audio&Video Recorder User manual Model#: IV-PBC-01 12000 Ford Road, Suite # 110, Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.com 1 1. Introduction Digital IDView sincerely
More informationAspect 2 Circuit Digital Scene Control
Aspect 2 Circuit Digital Scene Control S p e c i f i c a t i o n 2 circuits of trailing edge dimming 500W total between the two circuits Both circuits feature independent overload, short-circuit and open-circuit
More informationT Series LED Remote Controller
T Series LED Remote Controller ( This manual applies to: T1/T2/T2M/T3/T3M/T3X) T1 T2 T2M T3 T3M T3X Dimming (8 zones) Color Temperature Color Temperature (8 zones) RGB Sync Control RGB Zone Control (10
More informationCM-T10-PRO and PRO-E. Wireless Control for ColorMaker Series LED Fixtures with ColorRoll Technology User s Manual
CM-T10-PRO and PRO-E Wireless Control for ColorMaker Series LED Fixtures with ColorRoll Technology User s Manual Introduction CM-T10-PRO and CM-T10-PRO-E (Enhanced) This manual covers both the CM-T10-PRO
More informationInstallation and User Guide 458/CTR8 8-Channel Ballast Controller Module
Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach
More informationT Series LED Remote Controller
T Series LED Remote Controller ( This manual applies to: T1/T2/T2M/T3/T3M/T3X) T1 T2 T2M T3 T3M T3X Dimming (8 zones) Color Temperature Color Temperature (8 zones) RGB Sync Control RGB Zone Control (10
More informationBattery Operated Controllers
ALL SEASONAL ADJUSTMENT 1 Battery Operated Controllers Owner s Manual and Programming Instructions RUN PRG SENSOR BYPASS SYSTEM OFF CURRENT TIME/DAY ACTIVE MANUAL-ALL STATIONS START TIMES MANUAL-ONE STATION
More informationChapter 23 Dimmer monitoring
Chapter 23 Dimmer monitoring ETC consoles may be connected to ETC Sensor dimming systems via the ETCLink communication protocol. In this configuration, the console operates a dimmer monitoring system that
More informationKD-CSW2x1. Operating Instructions. 2 Inputs to 1 Output Component Video/Audio Switcher. KD-CSW2x1 Operating Instructions.
KD-CSW2x1 2 Inputs to 1 Output Video/ Switcher Operating Instructions Key Digital, led by digital video pioneer Mike Tsinberg, develops and manufactures high quality, cutting-edge technology solutions
More informationVNS2210 Amplifier & Controller Installation Guide
VNS2210 Amplifier & Controller Installation Guide VNS2210 Amplifier & Controller Installation 1. Determine the installation location for the VNS2210 device. Consider the following when determining the
More information3200NT System 14. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference
3200NT System 14 Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference Table of Contents Job Specification Sheet... 3 Timer Operation... 4 System Operation In Service...
More informationTL5024 MEMORY LIGHTING CONSOLE OWNERS MANUAL. Version 1.01
TL5024 MEMORY LIGHTING CONSOLE OWNERS MANUAL Version 1.01 09/22/2017 Page 2 of 14 SPECIFICATIONS Total channels Operating modes Scene memory Chase 12 or 24 depending on mode 12 channels x 2 manual scenes
More informationPRODUCT MANUAL. Chroma Flow PRO RGB LED Controller. and Receiver. Product Description. Main Functions: This manual reviews: Receiver.
Product Description The next generation of color changing Chroma Flow LED controllers is here with the new and even more advanced Chroma Flow PRO. The Chroma Flow PRO is a hand-held wireless remote control
More informationArduino Nixie Clock Modular Rev3
Arduino Nixie Clock Modular Rev3 Operating Instructions Firmware V348 Supported Models: Modular Revision 3 NixieClockUserManualV348 About this document This is the user instruction manual for the Nixie
More informationDMX48. User s instruction manual. 24 Channel DMX controller
WWW.LIGHTEMOTIONS.COM.AU DMX48 24 Channel DMX controller User s instruction manual This manual contains important information about the safe installation and use of this product Please read this instruction
More informationInstruction manual. DALI Gateway art Installation manual
Instruction manual DALI Gateway art. 01544 Installation manual Contents GENERAL FEATURES AND FUNCTIONALITY from page 5 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 6 COMMUNICATION OBJECTS GENERAL
More informationInformation Radio Transmitter Programming Guide
Information Radio Transmitter Programming Guide Front Panel 1. LCD Display: Displays information related to the current mode. Shows transmit frequency, elapsed or remaining time, either during record or
More informationMODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR
MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR USERS MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com 025-000412 Rev. B www.olsontech.com
More informationL, LTC, LTM, LT are registered trademarks of Linear Technology Corporation. Other product
DESCRIPTION WARNING! Do not look directly at operating LED. This circuit produces light that can damage eyes. Demo Circuit 1265 QUICK START GUIDE LTC3220/LTC3220-1 360mA Universal 18-Channel LED Driver
More informationTimer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions
Timer Modules EL11 24 Hour Module EL17 7 Day Module Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference and maintenance.
More informationManual for WMR-252 built-in receiver with universal dimmer
Manual for WMR-252 built-in receiver with universal dimmer A unique universal built-in wireless receiver with dimmer function for remotely controlling dimmable 230V LED bulbs, low-energy bulbs, incandescent
More informationCasambi App User Guide
Casambi App User Guide Version 1.5.4 2.1.2017 Casambi Technologies Oy Table of contents 1 of 28 Table of contents 1 Smart & Connected 2 Using the Casambi App 3 First time use 3 Taking luminaires into use:
More informationTimer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)
Timer Modules MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing) EMU11 24 Hour Module, EMU17 7 Day Module (With Housing Giving panel mounting facility) Installation & Operating Instructions 1 1.
More informationRADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE
TELECO AUTOMATION SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHONE: ++39.0438.388511 FAX: ++39.0438.388536 - www.telecoautomation.com This document is the property of Teleco Automation
More informationMains Supply. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length 300 m (with 1.5 mm² cable). Example: Belden 8471.
4Channel Ballast Controller (474) Product Description Installation and User Guide The Digidim 474 is a fourchannel ballast controller fitted with highinrush relays rated at 16 A per channel, which handle
More informationSET TOP BOX MODEL: GDB01SFV1 USER MANUAL
SET TOP BOX MODEL: USER MANUAL 1 2 3 4 5 6 7 8 Welcome Your Set Top Box 2.1 In The Box 2.2 Front View 2.3 Rear View Quick Setup 3.1 TV Connection 3.2 Recording from the set top box 3.3 Record one channel
More informationOTM FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL
OTM-4000 FREQUENCY AGILE 750MHz F.C.C. COMPATIBLE TELEVISION MODULATOR INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com 025-000331 REV B www.olsontech.com
More information