SAFETY. Unless otherwise stated TSL equipment may be installed at any angle or position within an operating temperature range of 5-30 C.

Size: px
Start display at page:

Download "SAFETY. Unless otherwise stated TSL equipment may be installed at any angle or position within an operating temperature range of 5-30 C."

Transcription

1

2 SAFETY Installation. Unless otherwise stated TSL equipment may be installed at any angle or position within an operating temperature range of 5-30 C. All TSL equipment conforms to the EC Low Voltage Directive: EC Low Voltage Directive (73/23/EEC)(OJ L )(LVD). Amendment: (93/68/EEC) (OJ L ). In all cases the frame of the equipment must be earthed on installation. Where appropriate, the earth pin on the IEC mains inlet connector is connected to the metal frame of the equipment, to 0 volts on the internal DC PSU and to signal ground unless otherwise stated. All metal panels are bonded together. Check that the voltage selector setting (if fitted) and the fuse rating is correct for the local mains supply. Due consideration for cooling requirements must be given when mounting the equipment. It is recommended that a 1RU of rack space, or a vent panel, should be left above and below the unit.

3 Page 3 WARRANTY, MAINTENANCE AND REPAIR All TSL products have a one year warranty period starting from the date it leaves the factory. A repair warranty is to apply. That is, the product is to be returned for repair with no replacement and an exchange shipping policy is also to apply. TSL offers a seven day DOA policy together with an exchange shipping policy. That is, if a product has been declared dead on arrival within a seven day period a warranty replacement will be shipped. A temporary replacement may be available where, for operational reasons, it is imperative that service is continued. The customer will be asked to enter into a loan agreement for the duration of repair. All faulty equipment returned to TSL for repair will, where possible, be returned to the customer within seven working days. TSL Returns Procedure Please telephone +44 (0) (Fax: +44 (0) ) and ask for Customer Support, detailing the model and serial number of the equipment, who will provide a Returns Number. This will enable us to track the unit effectively and will provide some information prior to the unit arriving. For each item, this unique Returns Number must be included with the Fault Report sent with the unit. A contact name and telephone number are also required with the Fault Report sent with the unit. Fault report details required. Company: Name: Address: Contact Name: Telephone number: Fax number: address: Returns Number: Symptoms of the fault (to include switch setting positions, input signals etc): Packing Please ensure that the unit is well packed as all mechanical damage is chargeable. TSL recommends that you insure your equipment for transit damage. The original packaging, when available, should always be used when returning equipment.

4 Page 4 This Page is Blank

5 Page 5 Contents Table of Contents 1. Introduction Different Product Versions In the Box Dimensions Operation Quick Start Guide Preset List Audio Global Analogue Reference Downmix Settings Labels Colour Input and Channel Order Scale and Loudness Setup Meter Text Read Out Backlight Level Controls Displays and Navigation Connectivity Mounting Signal Connections Preset Setup Labels Assign Loudness Preset Matrix Output Assign Meter Routing and assigning channels Meter Setup Scale Display Mode Bargraph Width Colour Normal... 31

6 Page Colour Under Under Level Window Text Starfish Setup Colour Compressor Op-Mode Window Height Loudness Setup Filter Scale Mode Sliding Window Reference Peak Level Gate Level Gate Level Peak Mode Reference Capture Loudness Option Software Updates... 39

7 Page 7 1. Introduction The latest member of TSL s Precision Audio Monitoring (PAM) product family, PAM PiCo is a compact, yet comprehensively equipped, standalone audio and Loudness meter featuring the revolutionary Starfish surround sound display. Designed for use in any operational position where at a glance audio metering is required. PAM PiCo is available in three formats; to display stereo, multichannel or surround sound audio from analogue, AES or embedded SDI signal sources, all measuring Loudness to international standards and recommendations including ITU, EBU R128 and ATSC. Both simple to use and easy to configure, PAM PiCo puts high quality metering within easy reach of anyone involved in sound production, from operators working throughout broadcast production to music studio technicians and record producers. Features: Loudness measurement to EBU, ITU and ATSC recommendations Audio de-embedding from SDI input, maximum 16 channels (PiCo 3 and 4 only) AES and analogue audio inputs USB Powered (plug top PSU included) Stereo metering with EBU Digital, BBC and EBU PPM, DIN, Nordic, VU and many other regional and international scales Moving Coil Meter emulation Sum and Difference (MS) Meter emulation LKFS or LUFS loudness scales Sliding Loudness Histogram display Phase indication bargraph Starfish display Numerical indication of Loudness and loudness range LRA Adjustable reference level User selectable bargraph colours and indication Variable gate settings Loudness Reclaim value True Peak display (flying peak and numerical display) Simple and intuitive front panel controls Online upgrade and update capability via PC (USB connection) Desk stand or an adjustable mounting bracket 1.1. Different Product Versions The PAM PiCo is available in four versions; all of the versions are powered by USB: PiCo One Master Stereo Meter, 2 x AES Inputs (4 x audio channels) or 1 x AES Input (2 x audio channels) + 1 x Analogue Pair. PiCo Two Master 5.1 Surround Meter, 3 x AES Inputs (6 x audio channels) + 1 x Analogue Pair PiCo Three Master 5.1 Surround Meter, 3G HD-SDI (auto-sensing with loop-through) 16 channel audio de-embedder (simultaneous display of any 8 channels)

8 Page 8 PiCo Four Master 5.1 Surround Meter, 3G HD-SDI (auto-sensing with loop-through) 16 channel audio de-embedder (simultaneous display of any 12 channels), 3x AES Inputs (6 x audio channels), 1x Analogue Pair (2 x audio channels), FFT/Spectrum Analyser 1.2. In the Box After obtaining the Product, inside the box you will find: o A PAM PiCo (version 1 or 2) o o o 1.3. Dimensions Unit Height: Width: Depth: Weight: A 1.5m interface cable to connect audio and power to the unit A USB -> PSU converter An adjustable mounting bracket 132 mm 88mm 18mm 355g Shipping Weight: 1.5kg Dimensions: 310mmx 310mm x 160mm Mounting Hole Pattern: 35mmx 35mm Thread Size: 4mm

9 Page 9 2. Operation The PAM PiCo is designed to be easy to operate and navigate. The touch sensitive buttons below the screen form a swipe sensitive strip that is used to switch between the displays and the buttons themselves are used for menu navigation and to start / stop / pause loudness measurement When starting the unit up for the first time, depending on the model it will be automatically set in a certain user setting. PiCo 1 User setting 2: 2.0 digital with a meter scale of EBU IEC PiCo 2 User setting 7: 5.1 digital with a meter scale of EBU IEC The user preset and quick setup menu can be found by swiping the touch panel from right to left, or by pushing the button labelled Menu -> and is shown below. There is no need to select any save option to store operational parameters such as presets as PAM PiCo has an automatic save function that stores all of the presets for power down and automatically recalls them when re-powered. Please allow at least fifteen seconds before powering down after updating the last option. The menu is split into 6 subfolders: Quick Start Guide Preset List Input and Channel Order Scale and Loudness Setup Meter Text Read Out Backlight Level 2.1. Quick Start Guide The Quick Start Guide is a pre-programmed text file which explains some basic features of the unit. By un-checking the box at the bottom, this menu will be minimised on start up.

10 Page Preset List The number of user presets for each product version is different: PiCo One: 5 presets PiCo Two: 11 presets The point of these presets is to configure different settings for varying operational function depending on the input and the required information and format for it to be displayed. This means you could switch quickly between two very different setups. If you swipe from right to left again it will take you to the setup menu. In this menu you will find 3 folders: About Preset [PRESET NAME] Audio Global Audio Global In the Audio Global section, there are the following folders which are configurable by the user: Analogue Reference Range: +12dBu -> +24dBu +15dBu is the DE standard +18dBu is the EBU standard +20dBu is the US standard The analogue reference folder allows you to set the FS (Full scale) Input, true peak voltage, reference level for analogue audio Downmix Settings

11 Page 11 This is the area of the PiCo where you can set the global output setting for any down mixed audio you want to monitor. You may wish to create a Downmix from your 5.1 selection in order to check stereo phase compatibility. This area is also designed for use when setting up a Sum/Difference meter mode. OUTPUT GAIN sets the output gain in db between -16 and +3. CENTR TO L/R allows you to adjust the gain in db of how much of the centre channel spills over to the left and right channels, also known as centre divergence. This can be set between 0dB and -6dB. MODE This allows you to set the Mode to either OFF, MS -3dB and MS -6dB Labels This folder allows users to rename both user presets and signal names. To change the name of any one item, use the MOVE and MOVE buttons to highlight the item. Then use the select button to select it. At this point an underscore symbol will appear underneath the far left symbol of the item s label. It is discernible by its colour change between white and purple. To move the underscore/selection symbol left, use the MOVE button while the symbol is flashing, to move right, use the MOVE button. When the underscore/select symbol is back at the far left symbol of the items label, pressing MOVE again will bring you back out of the individual symbol select cycle, to the item label select cycle. When you have found the individual symbol you wish to change press select. Next you can change the symbol in this area by pressing the MOVE and MOVE buttons. If the symbol in the selected position is blank, pressing the MOVE button will allow users to scroll through the list of symbols. Pressing the MOVE button will do nothing in this case.

12 Page 12 To move out of the symbol scrolling cycle, once the appropriate symbol has been chosen, pressing select will save the symbol and return the process to the individual symbol select cycle. On a PiCo 3 there are 32 signals which represent the 32 locations on the TDM bus, and each of these can have its own name. The surround channels are set as a default of 1-8. For more information see section Colour This folder allows the user to configure the colour of the meters, the options are: Blue Green Light Blue Red Violet Yellow White The default is Green. The colour of the meter can be changed by highlighting the current colour and pressing select. Then use the MOVE and MOVE buttons to scroll through the colour options Input and Channel Order This short menu allows you to quickly configure the type of input coming into the unit as well as the type of loudness measurement. On the Pico 2 there are the Options of: 2.0 Analogue 2.0 Digital 5.1 LRC Digital 5.1 LCR Digital

13 Page 13 The Pico One only takes a stereo input as a maximum, therefore the 5.1 options aren t available Scale and Loudness Setup This short menu allows you to configure the amplitude scale the bargraphs display on the screen and measure the incoming signals with, the bargraph width and the loudness scale. The Scale Type and Loudness setup are explained in further detail later in this manual; please see section and section 14.

14 Page Meter Text Read Out This menu allows quick configuring of the four lines of text that the unit displays above the bargraphs. This menu is a quick link similar to the window text setup in Meter Setup however, fewer options are available here, as the choices are kept to the most commonly used displays. For a detailed list of all possible options please see section Backlight Level The Backlight Level option allows users to quickly set the brightness for the unit

15 Page Controls At the base of the unit are three control buttons which use capacitive touch sensitive technology, which means that they will respond to physical contact by a finger, but not to devices such as a stylus or pen. The function of the buttons changes depending on which screen is displayed. The function of the button is indicated by the labels directly above them.

16 Page Displays and Navigation The displays can be split in to two main categories; Meter displays and Setup or menu displays. Setup Displays: There are two main screens here; the first is the Preset and Quick Setup Menu, where users can select which preset they wish to select or quickly change some more basic settings of the unit s performance.

17 Page 17 The second is the detailed Setup Menu, this has three key setup folders which allows users to personalise the presets: ABOUT PRESET [preset name] AUDIO GLOBAL Meter displays: There are three main screens here all depicted in the images below: The first screen shows the labelled input signal levels and the phase correlation of the Downmix. The second screen gives a histogram of the loudness, allowing you to choose to monitor this using either a sliding window or integral measurement. The parameters of these measurements are configurable in the setup menu.

18 Page 18 The third screen gives the labelled input signal levels along with a phase and Starfish display. All of these displays provide a numerical loudness reading along with other configurable pieces of data. The text displayed on all the screens, is the text that can be set in the quick setup menu (see section 2.5) or the window text menu (see section 12.7.). The default settings are explained below: Loudness Select: This displays the value and measurement of the current loudness preset. It can be split up as follows I (or) S (or) M (Integral or Short term or Momentary) Number: Value of the loudness measurement LKFS, LU or LUFS: Type of loudness measurement Sliding Max: This shows the maximum short term, sliding-window loudness measurement. Loudness LRA: This displays the loudness range, measured in LRA Peak Level Max: This shows the Peak level relative to the current meter scale being used. 5. Connectivity The 1.5m interface cable for the PAM PiCo is supplied with the unit and is the same for each: 1.5m, 3xBNC for unbalanced AES3 and USB power/data The signals each unit can handle are slightly different for each version: PiCo 1: D-15 -> 2xAES3, 1x Analogue Stereo Input and USB PiCo 2: D-15 -> 3xAES3, 1x Analogue Stereo Input and USB PiCo 3: D-15-> 3xAES3 (optional extra), 1x Analogue Stereo Input (optional extra) and USB 1x HD/SDI BNC Input, 1x HD/SDI BNC Output (active loop through) PiCo 4: D-15-> 3xAES3, 1x Analogue Stereo Input and USB, 1x HD/SDI BNC Input, 1x HD/SDI BNC Output (active loop through)

19 Page Mounting The unit comes with an adjustable mounting bracket that connects to the back panel of the PiCo. The end of the bracket with two holes should be connected to the PiCo and the end with four holes should be connected to the surface it is to be mounted on. When fixing the bracket to the PiCo, only the screws supplied should be used, this is because the screw holes on the unit are very shallow and using longer screws could cause damage. If using a thinner plate between the bracket and the unit, the supplied screws may also cause damage. If the unit is required to be fitted to a thin surface, use shorter screws, so that the screw is only engaging the case of the PiCo. As well as this there is the option to purchase a desktop bracket, pictured to the right. This stand can be placed on a flat surface and is good alternative if there is no convenient place to mount a wall bracket. Part Number: PAM PiCo B1

20 Page Signal Connections The pin-out for the back of the unit is shown below Signal Name Type Pin Number USB GND 1 USB +5V 9 USB D+ 2 USB D- 10 AES-3id input 1 HOT 3 AES-3id input 2 (PiCo 2 +) HOT 4 AES-3id input 3 (PiCo 2 +) HOT 12 AES Ground GND 11 Analogue Left HOT 6 Analogue Left COLD 14 Analogue Right HOT 8 Analogue Right COLD 15 Analogue Ground GND 7

21 Page Preset Setup Each preset comprises a set of configurable parameters including name, source, meter scale, loudness measurement and various other features. When initially entering the setup menu for any of the presets, if only the ABOUT folder is visible this means the USER MODE is set to RESTRICTED or NORMAL. Change to SUPERVISOR or ADMINISTRATOR to edit any of the settings of the presets. For regular use after all presets have been configured correctly for their use, make sure the USER MODE is set to NORMAL to avoid any accidental setting changes. The PAM PiCo comes with 11 factory presets : ANALOGUE DIGITAL LU D FS D 5 2.0,1 LU D 6 2.0,1 FS D DIGITAL LU D FS D ,1 LU D ,1 FS D All presets are configurable in the setup menu and can be changed, renamed and stored in the unit when power cycling. IMPORTANT NOTE: When changing a setting, unit must NOT be power cycled for AT LEAST 15 seconds after a change is made or else the unit will not save any changes.

22 By swiping the row of buttons from right to left when the preset you wish to change is highlighted you enter the SETUP menu: Page 22 This will be confirmed by the PRESET tab in the setup menu listing the preset you have selected in square brackets: [preset name]. To open the preset menu, highlight the tab as shown in the above image, then press Select. This will display the following screen: All the tabs above are configurable aspects of the meter performance.

23 Page Labels Assign The Label Assign tab allows users to change what the different signals represent. This is particularly useful if the signals you are monitoring are not coming in to the meter in a conventional manner, and is essential for proper routing through the use of the Matrix Output Assign. This is performed by selecting the signal channel you wish to change, then using the MOVE and MOVE buttons to change what the signal represents. Input represents the different types of signal coming into the unit or working throughout the unit: Internal internal signal processes that use the inputs to perform process such as Mixing, Turning off, Loudness output, Difference and more. Analogue this is where the stereo analogue inputs can be renamed from the list of labels. Digital This is where AES inputs can be renamed. Helpful particularly when changing between monitoring a 5.1 digital input and three stereo digital inputs. DeEmbedder Labels can be reassigned to the de-embedded audio coming into the unit via SDI. Output represents the labelling of the meters on the bargraph. N.B By assigning different channels to outputs via the matrix output assign, the meter labels that are chosen in the Output folder of Labels Assign are overridden and the meters will read the name of the channel you have assigned instead.

24 Page Loudness Preset Beneath each preset are six commonly used sets of defaults. In addition a USER mode allows custom variations to be created. To define the loudness measurement parameters, go to: SLIDE \ SLIDE \ SYSTEM \ PRESET [name] \ LOUDNESS PRESET and select the required set of parameters. USER must be selected if custom settings are to be created and used. Some key Loudness measurement presets are: R128 - The EBU standard ATSC - The US standard LEQM - is a weighted true average of the audio power level calculated using an adapted A- weighting curve. BCAP - UK commercials/adverts regulation from 2008 ARIB - Japanese TV programme standard from Association of Radio Industries and Business ARIB TR-32B

25 Page Matrix Output Assign The Matrix Output assign allows you to route physical signals from input sources to the TDM bus. Time-division multiplexing allows multiple physical signals to be routed seemingly simultaneously, when in reality they are actually split up on the high speed bus. This is how AES signals work. By changing the meter outputs you can reorder the signals on the output channel of the PiCo. There are 4 different types of signal which can be recognised and assigned in the matric output assign: Int Internal signal Ana Analogue signals Dig Digital Signal (AES) DeE De-Embedded Signals (HD/SDI) When using an SDI source make sure you have assigned the De-Embedded (DeE) signals to the output, otherwise the signals won t be detected. When using a digital audio source (AES) make sure that the outputs have Digital (Dig) signals assigned. When using an Analogue source make sure that Analogue (Ana) is selected as the source type. When using a SUM/DIFFERENCE or MIX from a combination of input signals make sure you select the relevant Internal signal.

26 Page 26 Using the MOVE and MOVE buttons, when a signal is selected in the matrix, you can route the signal to the different meter labels Meter The Matrix Output Assign option initially allows you, on each signal path, to choose between the following default signal labels: OFF: Int TONL: Int TONR: Int MIX: Int Internal signals DIFF: Int LOUD: Int INP: Int 1: Ana 2: Ana Analogue signals L: Dig R: Dig C: Dig LFE: Dig AES signals LS: Dig RS: Dig L: DeE R: DeE C: DeE LFE: DeE LS: DeE RS: DeE ML: DeE MR: DeE AUX1 : DeE AUX2: DeE 1: DeE 2: DeE 3: DeE 4: DeE 5: DeE 6: DeE DeEmbedded signals Routing and assigning channels The basic method for simple routing is: 1. Assign the correct labels for sources and bargraphs 2. Link the two together

27 Page 27 To route the signal to the meter, from the menu; Labels Assign->Input folder->select input Input channel order is now displayed. The line structure in this menu is: [label, labelnumber, labeltype] labeladdress Once input channel order is set, there are two options: 1. Route the signals to the bargraphs 2. Configure the bargraphs to make routing easier If following the second option, from the menu: Labels Assign->Output folder->meter Bargraph Labels and states are now displayed. The line structure in this menu is: [label, labelnumber, labeltype] meteraddress The order can be easily changed, for example, if your input consists of a stereo signal followed by a discrete 5.1 signal spread over four pairs from an embedded source, you can set the list to read as per the image to the left. Again, the order can be easily changed to better suit the input type. This is also where channels can be turned OFF. To route signals to the bargraphs, from the menu: Matrix Output Assign->Meter The routing between inputs and bargraph labels will be displayed. The line structure in this menu is: [inputlabel, inputtype] -> meteraddress: meterlabel In this folder, the routing can be easily changed.

28 Page 28 N.B Make sure the input you are assigning to a destination is the right type for the input you are supplying to the unit i.e. if you are supplying an AES source, make sure the input name on the unit has Dig in it somewhere.

29 Page Meter Setup Scale A variety of different meter scales are offered and the one selected is stored as part of each preset. Use the MOVE button to get to the presently selected preset. SELECT the preset, opening the folder then use the MOVE button to go to the BARGRAPH OPTION folder then go down to the SCALE folder. The full process is: SLIDE \ SLIDE \ SYSTEM \ PRESET [name] \ METER SETUP \ SCALE The scale currently assigned to that preset is highlighted and the MOVE and MOVE buttons allow a different one to be selected. The change is made by clicking SELECT on the required one. If no other changes are needed to that preset, going to EXIT allows the meter to return to the audio level display screen. Some of the different scales are explained below: BBC IEC 268 II VU EBU IEC is the BBC PPM scale - is the Volume Unit scale - is the EBU Digital standard scale *IEC 268 refers to the audio filtering applied to the signal to calculate the value Display Mode The bargraph display can be replaced by an emulation of a moving coil meter, or a combination of both moving coil and bargraph.

30 Page 30 To change this for any of the presents, first select the required preset. Use the navigation controls to select this folder inside METER SETUP. Select the style of meters using the MOVE to step to the required mode, then press SELECT. To return to the initial audio display mode from this, use the SLIDE function. The DUAL mode allows a single meter arc to display two signals by using a dual needle Bargraph Width The width of the individual bars can be changed between: NARROW NARROW + SPACE NORMAL NORMAL + SPACE WIDE WIDE + SPACE JUMBO JUMBO + SPACE

31 Page 31 Two examples of different bargraphs Narrow Jumbo Colour Normal Changes the colour of the meter for when the signal is normal (above the under level mark). The options are: GREEN YELLOW BLUE VIOLET LIGHT BLUE WHITE RED Colour Under This changes the colour of the meter for when the signal is below the under level. The options are the same as for the COLOUR NORMAL option.

32 Page Under Level Sets the under level cut-off, the point at which the bargraph will begin to display its data in a different colour. This value is settable between -24dB and 0dB. Is useful to alert of nearly peaking channels Window Text Window Text changes the values displayed on the meter screen. It is possible to view up to four at any one time from a choice of: RESERVED - Reserved for future updates LOUDNESS PRESET - The name of the loudness preset currently being used VOLUME - The volume of the output (3&4 only) PRESET AUDIO - Gives the name of the preset currently being used FILTER TYPE - The filter type currently being used SHORTTM TIME - Indicates the Short Term loudness integration time RESUME TIME - Reserved for future updates STOP TIME - Reserved for future updates START TIME - Reserved for future updates SMPTE TIME - Reserved for future updates PEAK LEVEL MAX - Shows the maximum peak in the level GATE HOLD - indicates if the un-gated loudness is under the gate level SHORTTM MAX - Shows the maximum level reached using a short term window MOMNTRY MAX - Shows the maximum level reached using a momentary window RECLAIM FACTOR - The difference between gated and un-gated loudness LOUDNESS LRA - Shows the Loudness Range INTEGRT - The Integral loudness measurement SHORTTM - The Short Term loudness measurement MOMNTRY - The Momentary loudness measurement LOUDNESS SELECT - The currently selected loudness measurement

33 Page 33 Two examples of alternative text selections are show below:

34 Page Starfish Setup The Starfish display provides a picture of a 5.1 surround audio field. The display has the front centre channel arranged towards the top with other directions as marked. Typical sound fields have energy in a variety of directions and more complex shapes are created which give an indication of the directions having significant amplitudes. The Starfish takes into account the summation occurs when there is coherent (in-phase) content between legs such as left and centre. Polarity inverted (out of phase) signals can cause the shape to be pulled inwards towards the centre point, reflecting the perceived cancellation that occurs. A yellow coloured trace indicates that there is a high degree of coherent signal content. When the signals are largely un-correlated, the trace becomes blue. When the predominant content is polarity inverted, a red section of the trace shows highlights that might have produced a phasing problem. The randomness of typical surround signals means an occasional glimpse of red should not be a cause for concern, though red showing for extended periods of time should be investigated as it can be a sign of a signal that will not fold-down well into stereo and mono. The first image shows a Starfish display, and the second shows the stereo equivalent Goniometer Colour Allows you to change the colour of the display between: BLUE GREEN LIGHT BLUE RED VIOLET YELLOW

35 Page Compressor Allows the changing of the Starfish compression rate between: SLOW FAST It also allows you to turn the compression ON or OFF Op-Mode This allows you to change between Jellyfish display and Starfish display. The Jellyfish display shows the same signal but as a circle Window Height This allows you to select between OFF - The display isn t turned on NORMAL - The display takes up half of the screen LARGE - The display takes up two thirds of the screen The difference in relative size is shown below: Large Normal

36 Page Loudness Setup In addition to the defaults offered in the presets, selecting USER as the loudness preset allows custom variations to be created. Beneath each preset are six commonly used sets of defaults. In addition a USER mode allows custom variations to be created. To define the loudness measurement parameters, go to: SLIDE \ SLIDE \ SETUP \ PRESET [name] \ LOUDNESS SETUP The variable parameters have options as follows: Filter The filter you choose here can be a K-FILTER or an LEQM: Scale Mode OR Two different scales have been adopted for displaying the loudness value. One of these is defined by the ITU in their document ITU BS1771 and that uses Loudness Units - LU. These have values ranging from -18 to +9 with the typical aiming point for signals being a specification close to the 0 point. The other commonly used scale has only negative values going down from a 0 LUFS mark at the very top of the scale. The required scale can be chosen by highlighting the parameter and using the MOVE and MOVE buttons followed by SELECT. OR Sliding Window The currently displayed loudness value is based on the averaged loudness values over a defined time window. Setting the window to 0 provides a display of value that are as instantaneous as the system permits. The window can be adjusted to be 0, 3, 10 or 30 seconds Reference A range of REFERENCE levels can be chosen for the purpose of loudness measurement as part of the loudness measurement standard which your organisation (or client) has adopted. It can be set between -9 and -24 dbfs (1 db steps). OR Peak Level The PEAK level is a user defined reference point and can be set between -1 to -10 dbfs (1 db steps).

37 Page Gate Level 1 It is often the high level parts of a programme which are often of most interest for assessing compliance with broadcast criteria. To prevent an extended length of low level programme content reducing the averaged loudness value to a degree that affects the measured value, the meter has an optional gating function. Once the signal drops below the gate threshold, the meter will continue to hold, display and use for averaging purposes, the previous value that was above the threshold. The gate threshold can be adjusted from -8 to -20 db in 1 db steps. Setting it to -20 causes the gate to remain open and the unit displays the actual loudness for the vast majority of the time Gate Level 2 The gate level can be an absolute value or a floating one. Absolute values offer a degree of simplicity but at the risk of a high setting causing gating out quieter sections which might sometime comprise a significant part of material such as a feature film soundtrack. Adopting a low absolute value can cause background noise that is at a relatively high level (for example a documentary by a waterfall) not to be gated out, even though it is not a significant contributor to the perceived loudness. Making the gate level relative may then offer results that more closely reflect perceived programme loudness Peak Mode Selecting DIGITAL based the reading on individual sample values. TRUE PEAK measurements take the maximum value of the interpolated wave shape Reference This is the frequency chosen for the calibration alignment and is either 400 or 1000 Hz Capture The graph mode can be initiated automatically when the signal starts. The options are MANUAL START, AUTO RESUME and AUTO START.

38 Page Loudness Option This allows customisation of the type of data being processed to get the loudness measurement. This can be selected to MOMENTARY, SLIDING or INTEGRT. To make a change select the line and it begins to blink between blue and black text. The MOVE and MOVE buttons allows scrolling through the options and when the required one is displayed, press the SELECT button. The MOVE buttons then resume their function of scrolling through other menu options.

39 Page Software Updates Online software updates ensure that PAM PiCo can be kept up to date with the latest international standards and recommendations. The latest software for the PAM PiCo can be downloaded via the TSL download page on the website The PiCo updater program is available as a.zip file from the TSL PPL website. You need to unzip the folder to the desktop of the PC you are using. To use the updater program, upon opening the program for the first time you need to select extract drivers from the dropdown menu and then click proceed. The drivers for Windows Vista/7/XP are located in the.zip file that contained the updater program. To update the software connect the USB of the PiCo breakout cable to your PC while it is connect to the unit. This will power the unit on. Now on the select serial port dropdown menu select the port which the unit is connected to, then click find instrument. If the port you have connected to does not appear at first then click Refresh ports

40 Page 40 Once your unit is located, click Connect. This will display the following screen: Using the browse button, select the CDP file you wish to load. This could be either a new update or an older version of the software. By clicking Advanced you are given three options: Clone instrument (Save to file) allows you to create a backup file of the instrument and all its settings so that they can be cloned for multiple copies, or reloaded in an emergency where all the settings have been changed. Clone instrument (Load from file) loads a copy of the backed up setup data which is made from the above process. Install SWA licence is used to activate a licence for a selected PiCo to allow users to perform feature upgrades and other functions while interfacing with a PC.

41 Page 41 Once you have chosen the file you wish to load click next. After clicking yes on the screen above, the unit will begin to load the new software. When it is complete the PiCo will restart and it will then be usable with the new software version installed. Drivers - Please note that a set of PAM PiCo drivers are contained within the updater.zip file. You may need to install them in order for your computer to recognise PAM PiCo and for the updater programme to function properly.

AMU1-BHD+ Audio monitoring Unit

AMU1-BHD+ Audio monitoring Unit AMU1-BHD+ Audio monitoring Unit Handbook TSL Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200, FAX +44 (0)1628 676299 AMU1-BHD+-6 1 ISSUE 6 SAFETY Installation. Unless otherwise

More information

AMU2-2MHD+ Audio monitoring Unit

AMU2-2MHD+ Audio monitoring Unit AMU2-2MHD+ Audio monitoring Unit Handbook TSL Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200, FAX +44 (0)1628 676299 AMU2-2MHD+-6 1 ISSUE 5 SAFETY Installation. Unless otherwise

More information

INTRODUCTION... 4 BEFORE YOU BEGIN... 6 ABOUT THIS MANUAL... 6 OTHER IMPORTANT NOTES... 7 QUICK GUIDE... 8 IF YOU JUST WANT TO GET GOING...

INTRODUCTION... 4 BEFORE YOU BEGIN... 6 ABOUT THIS MANUAL... 6 OTHER IMPORTANT NOTES... 7 QUICK GUIDE... 8 IF YOU JUST WANT TO GET GOING... 1 INTRODUCTION... 4 BEFORE YOU BEGIN... 6 ABOUT THIS MANUAL... 6 OTHER IMPORTANT NOTES... 7 QUICK GUIDE... 8 IF YOU JUST WANT TO GET GOING... 8 BASIC OPERATION... 9 MOUNTING YOUR PAM PICO... 9 POWER SUPPLY...

More information

AVMU2-BHD+/3G Audio monitoring Unit

AVMU2-BHD+/3G Audio monitoring Unit AVMU2-BHD+/3G Audio monitoring Unit Handbook Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200, FAX +44 (0)1628 676299 AVMU2-BHD+/3G 1 ISSUE 3 SAFETY

More information

DK METER User Manual. DK METER Audio & Loudness Metering Complete

DK METER User Manual. DK METER Audio & Loudness Metering Complete DK METER User Manual DK METER Audio & Loudness Metering Complete 1 INTRODUCTION... 4 BEFORE YOU BEGIN... 4 ABOUT THIS MANUAL... 4 OTHER IMPORTANT NOTES... 5 QUICK GUIDE... 6 IF YOU JUST WANT TO GET GOING...

More information

DK Meter Audio & Loudness Metering Complete. Safe & Sound

DK Meter Audio & Loudness Metering Complete. Safe & Sound DK Meter Audio & Metering Complete Safe & Sound DK Meter at a glance Complete Audio & one-box metering Hassle-free Flexibility plug, preset and play High Quality Tools, yet outstanding value for money

More information

AMU2-8HD+ & 3G Audio Monitoring Units Handbook TSL Vanwall Road, Maidenhead, Berkshire, SL6 4UB

AMU2-8HD+ & 3G Audio Monitoring Units Handbook TSL Vanwall Road, Maidenhead, Berkshire, SL6 4UB AMU2-8HD+ & 3G Audio Monitoring Units Handbook TSL Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200, FAX +44 (0)1628 676299 AMU2-8HD+/3G 1 Issue 1 SAFETY Installation. Unless otherwise

More information

DRAFT RELEASE FOR BETA EVALUATION ONLY

DRAFT RELEASE FOR BETA EVALUATION ONLY IPM-16 In-Picture Audio Metering User Manual DRAFT RELEASE FOR BETA EVALUATION ONLY Ver 0.2 April 2013 1 Contents Introduction...3 In Picture Audio Meter Displays...4 Installation...7 External Audio Board

More information

Sound Measurement. V2: 10 Nov 2011 WHITE PAPER. IMAGE PROCESSING TECHNIQUES

Sound Measurement. V2: 10 Nov 2011 WHITE PAPER.   IMAGE PROCESSING TECHNIQUES www.omnitek.tv IMAGE PROCESSING TECHNIQUES Sound Measurement An important element in the assessment of video for broadcast is the assessment of its audio content. This audio can be delivered in a range

More information

Contents. Welcome to LCAST. System Requirements. Compatibility. Installation and Authorization. Loudness Metering. True-Peak Metering

Contents. Welcome to LCAST. System Requirements. Compatibility. Installation and Authorization. Loudness Metering. True-Peak Metering LCAST User Manual Contents Welcome to LCAST System Requirements Compatibility Installation and Authorization Loudness Metering True-Peak Metering LCAST User Interface Your First Loudness Measurement Presets

More information

Data Sheet SurroundMonitor Series

Data Sheet SurroundMonitor Series Data Sheet Series 1 Overview 2 1 1 2 Remote Display 30010 (optional) 8-channel Multistandard PPM Surround Sound Analyzer Loudness Loudness Leq LRA PPM Dialnorm Vectorscope Correlator RtA Downmix AeS3 Status

More information

Model 7600 HD/SD Embedder/ Disembedder Data Pack

Model 7600 HD/SD Embedder/ Disembedder Data Pack Model 7600 HD/SD Embedder/ Disembedder Data Pack E NSEMBLE D E S I G N S Revision 2.1 SW v2.0.1 This data pack provides detailed installation, configuration and operation information for the 7600 HD/SD

More information

BM-A1-E16SHD V2.2. Manual BM-A1-E16SHD. 16 Channel Digital Audio Monitor. User s Guide. Page 1

BM-A1-E16SHD V2.2. Manual BM-A1-E16SHD. 16 Channel Digital Audio Monitor. User s Guide. Page 1 BM-A1-E16SHD V2.2 Manual BM-A1-E16SHD 16 Channel Digital Audio Monitor User s Guide Page 1 BEL (Digital Audio) Ltd., has made every effort to ensure the accuracy of information contained within this document,

More information

AM-4 Audio Monitor. Videoquip Research Limited 595 Middlefield Road, Unit #4 Scarborough, Ontario, Canada. MIV 3S2

AM-4 Audio Monitor. Videoquip Research Limited 595 Middlefield Road, Unit #4 Scarborough, Ontario, Canada. MIV 3S2 AM-4 Audio Monitor Videoquip Research Limited 595 Middlefield Road, Unit #4 Scarborough, Ontario, Canada. MIV 3S2 (416) 293-1042 1-888-293-1071 www.videoquip.com AM-4 4 channel Analog, AES3 Digital, SDI

More information

SAFETY. Unless otherwise stated TSL equipment may be installed at any angle or position within an -

SAFETY. Unless otherwise stated TSL equipment may be installed at any angle or position within an - P a g e 2 SAFETY Installation. Unless otherwise stated TSL equipment may be installed at any angle or position within an - All TSL equipment conforms to the EC Low Voltage Directive: EC Low Voltage Directive

More information

C8491 C8000 1/17. digital audio modular processing system. 3G/HD/SD-SDI DSP 4/8/16 audio channels. features. block diagram

C8491 C8000 1/17. digital audio modular processing system. 3G/HD/SD-SDI DSP 4/8/16 audio channels. features. block diagram features 4 / 8 / 16 channel LevelMagic2 SDI-DSP with level or loudness (ITU-BS.1770-1/ ITU-BS.1770-2, EBU R128) control 16 channel 3G/HD/SD-SDI de-embedder 16 in 16 de-embedder matrix 16 channel 3G/HD/SD-SDI

More information

DIGITAL SPEAKER MANAGEMENT UK

DIGITAL SPEAKER MANAGEMENT UK DSM2-6mkII DIGITAL SPEAKER MANAGEMENT 170.659UK Features 96kHz sampling frequency, 32-bit A/D and D/A converter, 24-bit DSP processor Input channel: 6-band parametric EQ, Delay, Polarity Output channel:

More information

CEDAR Series. To learn more about Ogden CEDAR series signal processing platform and modular products, please visit

CEDAR Series. To learn more about Ogden CEDAR series signal processing platform and modular products, please visit CEDAR Series The CEDAR platform has been designed to address the requirements of numerous signal processing modules. Easily-installed components simplify maintenance and upgrade. To learn more about Ogden

More information

3GSDI Audio Embedder

3GSDI Audio Embedder 1080P 3GSDI Audio Embedder GEF-SDI-AUDE User Manual www.gefenpro.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM

More information

AVM-T-MIX and AVM-T-MIX SD. Touch Series Audio Monitoring Unit. Handbook Version One

AVM-T-MIX and AVM-T-MIX SD. Touch Series Audio Monitoring Unit. Handbook Version One Touch Series Audio Monitoring Unit Handbook Version One TSL Vanwall Road, Maidenhead, Berkshire, SL6 4UB - United Kingdom Telephone +44 (0)1628 676200 FAX +44 (0)1628 676299 P a g e 2 SAFETY Installation.

More information

Recording to Tape (Analogue or Digital)...10

Recording to Tape (Analogue or Digital)...10 c o n t e n t s DUAL MIC-PRE Green Dual Mic Pre (introduction).............................4 Section (i): Setting Up Power Connections...........................................4 Power Supply................................................5

More information

DLM471S-5.1 MULTICHANNEL AUDIO LEVEL MASTER OPERATION MANUAL IB B. (Mounted in RMS400 Rack Mount & Power Supply) (One of 4 Typical Cards)

DLM471S-5.1 MULTICHANNEL AUDIO LEVEL MASTER OPERATION MANUAL IB B. (Mounted in RMS400 Rack Mount & Power Supply) (One of 4 Typical Cards) DLM471S-5.1 (Mounted in RMS400 Rack Mount & Power Supply) MULTICHANNEL AUDIO LEVEL MASTER (One of 4 Typical Cards) OPERATION MANUAL IB6432-02B TABLE OF CONTENTS PAGE 1.0 GENERAL DESCRIPTION 2 2.0 INSTALLATION

More information

User s Guide Version /01/2012

User s Guide Version /01/2012 BM- A2-16SHD 2012 BM-A2-16SHD 16 Channel Digital Audio Monitor User s Guide Version 1.0 01/01/2012 Version 1.0 Page 1 BEL (Digital Audio) Ltd., has made every effort to ensure the accuracy of information

More information

BM- AV1- E16SHD Manual BM-AV1-E16SHD. 16 Channel Digital Audio Monitor. User s Guide. Version /01/2013. Version 2.

BM- AV1- E16SHD Manual BM-AV1-E16SHD. 16 Channel Digital Audio Monitor. User s Guide. Version /01/2013. Version 2. Manual BM-AV1-E16SHD 16 Channel Digital Audio Monitor User s Guide Version 2.1 14/01/2013 Version 2.1 Page 1 BEL (Digital Audio) Ltd., has made every effort to ensure the accuracy of information contained

More information

RMS 8424S Quick Start

RMS 8424S Quick Start VIEWSIZE THE WORLD RMS 8424S Quick Start Standard 4 unit rack mount size 8 inch LCD 2 1024 3 (RGB) 600 16:9 / 4:3 adjustable SDI/HDMI embedded audio output via 3.5mm earphone socket Support SDI/DVI audio

More information

3G/HD/SD dual channel audio embedder/de-embedder

3G/HD/SD dual channel audio embedder/de-embedder 3G/ dual channel audio embedder/de-embedder Dual channel audio embedder/de-embedder, with two independent video channels Being dual channel makes the audio embedder/de-embedder perfect for those pricesensitive

More information

1080P. 3GSDI Audio De-Embedder. GEF-SDI-AUDD User Manual.

1080P. 3GSDI Audio De-Embedder. GEF-SDI-AUDD User Manual. 1080P 3GSDI Audio De-Embedder GEF-SDI-AUDD User Manual www.gefenpro.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00

More information

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL COMPOSITE VIDEO METER MODEL VLM- COMPOSITE VIDEO METER MODEL VLM- NTSC TECHNICAL INSTRUCTION MANUAL VLM- NTSC TECHNICAL INSTRUCTION MANUAL INTRODUCTION EASY-TO-USE VIDEO LEVEL METER... SIMULTANEOUS DISPLAY...

More information

BM-A2-4SHD MKII. Ver Channel Digital Audio Monitor. User s Guide. Page 1

BM-A2-4SHD MKII. Ver Channel Digital Audio Monitor. User s Guide. Page 1 BM-A2-4SHD MKII BM-A2-4SHD MKII 4 Channel Digital Audio Monitor User s Guide Page 1 BEL (Digital Audio) Ltd., has made every effort to ensure the accuracy of information contained within this document,

More information

Data Sheet SurroundControl Series

Data Sheet SurroundControl Series Data Sheet SurroundControl 00 Series Overview Remote Control 000 SurroundControl 00 Remote Display 000 (optional) -ch. Monitoring Controller Surround Sound Analyzer Loudness Loudness Leq LRA PPM Dialnorm

More information

Standard Definition. Commercial File Delivery. Technical Specifications

Standard Definition. Commercial File Delivery. Technical Specifications Standard Definition Commercial File Delivery Technical Specifications (NTSC) May 2015 This document provides technical specifications for those producing standard definition interstitial content (commercial

More information

BM-A1-2SHD MKII. Ver1.1 BM-A1-2SHD MKII. 2 Channel Digital Audio Monitor. User s Guide. Page 1

BM-A1-2SHD MKII. Ver1.1 BM-A1-2SHD MKII. 2 Channel Digital Audio Monitor. User s Guide. Page 1 BM-A1-2SHD MKII BM-A1-2SHD MKII 2 Channel Digital Audio Monitor User s Guide Page 1 BEL (Digital Audio) Ltd., has made every effort to ensure the accuracy of information contained within this document,

More information

S0 Radio Broadcasting Mixer. June catalogue. Manufacturers of audio & video products for radio & TV broadcasters

S0 Radio Broadcasting Mixer. June catalogue. Manufacturers of audio & video products for radio & TV broadcasters S0 Radio Broadcasting Mixer June 2012 catalogue Manufacturers of audio & video products for radio & TV broadcasters S0 Radio Broadcasting Mixer A simple radio mixer for novice and professional users The

More information

CLA MixHub. User Guide

CLA MixHub. User Guide CLA MixHub User Guide Contents Introduction... 3 Components... 4 Views... 4 Channel View... 5 Bucket View... 6 Quick Start... 7 Interface... 9 Channel View Layout..... 9 Bucket View Layout... 10 Using

More information

HD-CM HORIZON DIGITAL CABLE METER

HD-CM HORIZON DIGITAL CABLE METER HD-CM OFF! Max RF i/p = +17dBm 75Ω Max AC/DC i/p = 120Vrms MENU INPUT ON HORIZON DIGITAL CABLE METER Horizon Global Electronics Ltd. Unit 3, West Side Flex Meadow Harlow, Essex CM19 5SR Phone: +44(0) 1279

More information

Why We Measure Loudness

Why We Measure Loudness Menu Why We Measure Loudness Measuring loudness is key to keeping an audience tuned to your channel. Image: digital.eca.ed.ac.uk It is all very well being able to quantify the volume of a signal, however,

More information

Model 6010 Four Channel 20-Bit Audio ADC Data Pack

Model 6010 Four Channel 20-Bit Audio ADC Data Pack Model 6010 Four Channel 20-Bit Audio ADC Data Pack Revision 3.1 SW v1.0.0 This data pack provides detailed installation, configuration and operation information for the Model 6010 Four Channel 20-bit Audio

More information

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011 RD - 122 RACK MOUNT DIMMER OWNERS MANUAL VERSION 1.3 03/09/2011 Page 2 of 14 TABLE OF CONTENTS UNIT DESCRIPTION AND FUNCTIONS 3 POWER REQUIREMENTS 3 INSTALLATION 3 PLACEMENT 3 POWER CONNECTIONS 3 OUTPUT

More information

SC-HD-2A HDMI Scaler & Audio Embedder / Extractor

SC-HD-2A HDMI Scaler & Audio Embedder / Extractor User s Manual SC-HD-2A HDMI Scaler & Audio Embedder / Extractor Scale HDMI or DVI video Embed Digital or Analog Audio into HDMI output Extract (De-embed) Digital and Analog Audio from HDMI input UMA1246

More information

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

Model 5250 Five Channel Digital to Analog Video Converter Data Pack Model 5250 Five Channel Digital to Analog Video Converter Data Pack E NSEMBLE D E S I G N S Revision 3.1 SW v2.0.1 This data pack provides detailed installation, configuration and operation information

More information

Model 5240 Digital to Analog Key Converter Data Pack

Model 5240 Digital to Analog Key Converter Data Pack Model 5240 Digital to Analog Key Converter Data Pack E NSEMBLE D E S I G N S Revision 2.1 SW v2.0 This data pack provides detailed installation, configuration and operation information for the 5240 Digital

More information

FS1-X. Quick Start Guide. Overview. Frame Rate Conversion Option. Two Video Processors. Two Operating Modes

FS1-X. Quick Start Guide. Overview. Frame Rate Conversion Option. Two Video Processors. Two Operating Modes FS1-X Quick Start Guide Overview Matching up and synchronizing disparate video and audio formats is a critical part of any broadcast, mobile or post-production environment. Within its compact 1RU chassis,

More information

User Manual 15" LCD Open frame SAW Touch Monitor KOT-0150US-SA4W. Table of Contents

User Manual 15 LCD Open frame SAW Touch Monitor KOT-0150US-SA4W. Table of Contents User Manual 15" LCD Open frame SAW Touch Monitor KOT-0150US-SA4W Table of Contents Chapter 1. Introduction...2 1.1 Product Description 1.2 About the Product Chapter 2. Installation and Setup...2 2.1 Unpacking

More information

V pro8 QUICK START GUIDE

V pro8 QUICK START GUIDE QUICK START GUIDE Welcome to your V pro8 FIRST STEPS POWERING ON CONNECTING YOUR COMPUTER Thank you for buying the Lawo V pro8, a true high-quality product developed and manufactured in Rastatt, Germany.

More information

Model 7130 HD Downconverter and Distribution Amplifier Data Pack

Model 7130 HD Downconverter and Distribution Amplifier Data Pack Model 7130 HD Downconverter and Distribution Amplifier Data Pack E NSEMBLE D E S I G N S Revision 1.0 SW v1.0 www.ensembledesigns.com 7130-1 Contents MODULE OVERVIEW 3 Audio Handling 3 Control 3 Metadata

More information

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1. MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Rev. 1.01 Page i Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice

More information

HDB

HDB GDB990-950-900-550-500 HDB990-950-900-550-500 3Gb/s, HD, SD digital or analog audio de-embedder with TWINS dual A Synapse product COPYRIGHT 2012 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED NO PART OF THIS

More information

C8000. switch over & ducking

C8000. switch over & ducking features Automatic or manual Switch Over or Fail Over in case of input level loss. Ducking of a main stereo or surround sound signal by a line level microphone or by a pre recorded announcement / ad input.

More information

Operating Instructions

Operating Instructions Broadcast A/V Division Model No. M-LYNX-702W Dual 7 High Resolution Rack Mount Display with Waveform Operating Instructions V.1.0 Table of Contents 1. PRODUCT DESCRIPTION... 3 2. MENU SETTING... 6 3. SPECIFICATIONS...

More information

SNG-2150C User s Guide

SNG-2150C User s Guide SNG-2150C User s Guide Avcom of Virginia SNG-2150C User s Guide 7730 Whitepine Road Revision 001 Richmond, VA 23237 USA GENERAL SAFETY If one or more components of your earth station are connected to 120

More information

Part 2. LV5333 LV5381 LV5382 LV7390 LV7770 LV7330 LV5838 LT4610 LT4600 LT4446 LT4100 LT4110 Accessories

Part 2. LV5333 LV5381 LV5382 LV7390 LV7770 LV7330 LV5838 LT4610 LT4600 LT4446 LT4100 LT4110 Accessories Part 2 LV5333 LV5381 LV5382 LV7390 LV7770 LV7330 LV5838 LT4610 LT4600 LT4446 LT4100 LT4110 Accessories LT4610SER01 OPTION LTC IN/OUT GPS IN CW IN AES/EBU/OUT SILENCE OUT WCLK OUT ETHERNET GENLOCK

More information

Element 78 MPE-200. by Summit Audio. Guide To Operations. for software version 1.23

Element 78 MPE-200. by Summit Audio. Guide To Operations. for software version 1.23 Element 78 MPE-200 by Summit Audio Guide To Operations for software version 1.23 TABLE OF CONTENTS IMPORTANT SAFETY AND GROUNDING INSTRUCTIONS COVER 1. UNPACKING AND CONNECTING...3 AUDIO CONNECTIONS...4

More information

DSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator.

DSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator. DSA-1 The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator. The DSA-1 is an invaluable trouble-shooting tool for digital audio equipment and installations. It is unique as a handportable,

More information

2x2 HDMI Matrix Switch - 4K with Fast Switching and Auto-Sensing

2x2 HDMI Matrix Switch - 4K with Fast Switching and Auto-Sensing 2x2 HDMI Matrix Switch - 4K with Fast Switching and Auto-Sensing Product ID: VS222HD4K Save time and hassle by automatically switching between your HDMI audio/video sources. This 2x2 HDMI matrix switcher

More information

FREE TV AUSTRALIA OPERATIONAL PRACTICE OP- 59 Measurement and Management of Loudness in Soundtracks for Television Broadcasting

FREE TV AUSTRALIA OPERATIONAL PRACTICE OP- 59 Measurement and Management of Loudness in Soundtracks for Television Broadcasting Page 1 of 10 1. SCOPE This Operational Practice is recommended by Free TV Australia and refers to the measurement of audio loudness as distinct from audio level. It sets out guidelines for measuring and

More information

Version 1.2 User Manual

Version 1.2 User Manual Version 1.2 User Manual Last Revised 31 May 2013 Copyright VSonics Limited 2010-13 1 End User License Agreement PLEASE READ THE FOLLOWING LEGAL AGREEMENT CAREFULLY PRIOR TO USING THE VMETERS SOFTWARE PROVIDED

More information

SCM820 Digital IntelliMix Automatic Mixer SEAMLESS MIXING. ADVANCED CONTROL.

SCM820 Digital IntelliMix Automatic Mixer SEAMLESS MIXING. ADVANCED CONTROL. SCM820 Digital IntelliMix Automatic Mixer SEAMLESS MIXING. ADVANCED CONTROL. SCM820 Digital IntelliMix Automatic Mixer The SCM820 is the flagship Shure digital automatic mixer for seamless, natural-sounding

More information

VXF7 QUICKSTART GUIDE. 7" 4K Full HD HDMI/3G-SDI On-Camera Monitor

VXF7 QUICKSTART GUIDE. 7 4K Full HD HDMI/3G-SDI On-Camera Monitor VXF7 QUICKSTART GUIDE 7" K Full HD HDMI/G-SDI On-Camera Monitor What s Included x VXF7 Monitor x AC Adapter x Camera Shoe Mount (SM-0) x Screen Cleaning Wipe x Screen Protector x Sunhood x Canon E6 Battery

More information

Models 5360 and 5365 Four Channel Analog to Digital Video Converters and Embedders Data Pack

Models 5360 and 5365 Four Channel Analog to Digital Video Converters and Embedders Data Pack Models 5360 and 5365 Four Channel Analog to Digital Video Converters and Embedders Data Pack E NSEMBLE D E S I G N S Revision 1.3 SW v2.2.1 This data pack provides detailed installation, configuration

More information

Focusrite Audio Engineering Ltd. Blue Range Modules. User Guide. Jan Contents

Focusrite Audio Engineering Ltd. Blue Range Modules. User Guide. Jan Contents Focusrite Audio Engineering Ltd Blue Range Modules User Guide Jan 2001 o o o o o o o o o o o o o o o o o o o o o o o o o o o Contents Introduction Overviews Unpacking Power & Signal Connections Earths

More information

IQBSFR AES/EBU Digital Audio ReMapper with Stereo Combiner and Gain Control

IQBSFR AES/EBU Digital Audio ReMapper with Stereo Combiner and Gain Control IQBSFR AES/EBU Digital Audio ReMapper with Stereo Combiner and Gain Control C Module Description The IQBSFR accepts two isosynchronous AES/EBU inputs (4 input subframes). Digital audio sample rates of

More information

S1 Digital/Analogue Radio Broadcast Mixer September 2009

S1 Digital/Analogue Radio Broadcast Mixer September 2009 S1 Digital/Analogue Radio Broadcast Mixer September 2009 www.sonifex.co.uk t: +44 (0)1933 650 700 f: +44 (0)1933 650 726 sales@sonifex.co.uk S1 Radio Digital/Analogue Broadcast Mixer Radio Broadcast Mixer

More information

ivw-fd133 Video Wall Controller MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Page i Rev. 1.

ivw-fd133 Video Wall Controller MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Page i Rev. 1. MODEL: ivw-fd133 Video Wall Controller Supports 3 x 3 and 2 x 2 Video Wall Array User Manual Rev. 1.01 Page i Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior

More information

Intelligent Security and Fire Ltd

Intelligent Security and Fire Ltd User Manual Product ranges covered by this manual Vi-P14 Vi-P14A Document Reference Date Firmware Vi-Q4C1 Viq601a.doc 26/11/2009 From Viq001a21 Videoswitch Telephone 01252-851510 Ocean House, Redfields

More information

TECHNICAL MEDIA SPECIFICATION ON THE FILE BASED SUBMISSION OF MATERIALS TO BE AIRED

TECHNICAL MEDIA SPECIFICATION ON THE FILE BASED SUBMISSION OF MATERIALS TO BE AIRED TECHNICAL MEDIA SPECIFICATION ON THE FILE BASED SUBMISSION OF MATERIALS TO BE AIRED 2015.12.11 Contents 1. Introduction... 3 2. Material File Format... 4 3. Video properties... 6 4. Audio properties...

More information

The 6700 series Panel lock and destination protect

The 6700 series Panel lock and destination protect Table of Contents 1 Introduction 4 2 Panel types 5 The 6700 series Panel lock and destination protect 3 Installation 10 Connector I/O Installing the power supply Earthing the panel Inserting and removing

More information

C-net WIND. User s Guide

C-net WIND. User s Guide C-net WIND User s Guide EMC Directive 89/336/EEC This product has been designed to be compliant with the above EMC Directive. Maximum performance and compliance with the EMC Directive can only be ensured

More information

TELETEST Ltd 4-6 Shelley Road, Bournemouth, BH1 4HY, UK Tel: Intl: Web:

TELETEST Ltd 4-6 Shelley Road, Bournemouth, BH1 4HY, UK Tel: Intl: Web: TELETEST Ltd 4-6 Shelley Road, Bournemouth, BH1 4HY, UK Tel: 01202 900160 Intl: +44 1202... E-Mail: sales@teletest.tv Web: www.teletest.tv 500m Long Range HDSDI Radio Link Data Sheet OZE4640 Transmitter

More information

Signal Stability Analyser

Signal Stability Analyser Signal Stability Analyser o Real Time Phase or Frequency Display o Real Time Data, Allan Variance and Phase Noise Plots o 1MHz to 65MHz medium resolution (12.5ps) o 5MHz and 10MHz high resolution (50fs)

More information

Model: S-1071H 7" Broadcast On-camera 3GSDI&HDMI LCD Monitor. User Manual. Please read this User Manual throughout before using.

Model: S-1071H 7 Broadcast On-camera 3GSDI&HDMI LCD Monitor. User Manual. Please read this User Manual throughout before using. Model: S-1071H 7" Broadcast On-camera 3GSDI&HDMI LCD Monitor User Manual Please read this User Manual throughout before using. Preface Congratulations on your purchase of this product. Please read this

More information

VSP 198CVS Quick Start

VSP 198CVS Quick Start VIEWSIZE THE WORLD VSP 198CVS Quick Start Max 2048 1152@60Hz/2560 1152 50Hz input/output resolution User customize output resolution 3G/HD/SD-SDI input Multiple cascade mapping for super resolution DVI

More information

Audio Monitoring Units (AMU)

Audio Monitoring Units (AMU) PROFESSIONAL PRODUCTS GROUP Audio Monitoring Units (AMU) Professional Audio Monitoring Solutions A Smarter Choice in Audio Monitoring Audio Monitoring Units Product overview PAGE NO DISPLAY INPUTS OUTPUTS

More information

RELEASE NOTES. Introduction. Supported Devices. Mackie Master Fader App V4.5.1 October 2016

RELEASE NOTES. Introduction. Supported Devices. Mackie Master Fader App V4.5.1 October 2016 RELEASE NOTES Mackie Master Fader App V4.5.1 October 2016 Introduction These release notes describe changes and upgrades to the Mackie Master Fader app and DL Series mixer firmware since Version 4.5. New

More information

Quick Start Guide. Soundcraft Si Series Quick Start Guide Issue 1010

Quick Start Guide. Soundcraft Si Series Quick Start Guide Issue 1010 Quick Start Guide Soundcraft Si Series Quick Start Guide Issue 1010 Page 1 INTRODUCTION IMPORTANT Please read this manual carefully before using your mixer for the first time. Firstly, thanks for choosing

More information

CLOCKAUDIO. MR88 Automatic Microphone Mixer. Version 4.2

CLOCKAUDIO. MR88 Automatic Microphone Mixer. Version 4.2 CLOCKAUDIO MR88 Automatic Microphone Mixer Version 4.2 Clockaudio Limited,22 Arnside Road WATERLOOVILLE Hampshire. UK Tel : +44 (0)2392 251193 Fax : +44 (0)2392 251201 Email : sales@clockaudio.co.uk CONTENTS

More information

SX7. Saga 7" Super Bright HDMI/3G-SDI Field Monitor with 3D-LUTs. Quick Start Guide. What s Included CHECKED BY

SX7. Saga 7 Super Bright HDMI/3G-SDI Field Monitor with 3D-LUTs. Quick Start Guide. What s Included CHECKED BY SX7 Quick Start Guide Saga 7" Super Bright HDMI/3G-SDI Field Monitor with 3D-LUTs What s Included 1 x Saga X7 Monitor 1 x V-Mount Plate (Attached) 1 x Mini-XLR to P-TAP Cable 1 x Dual Sony L Battery Adapter

More information

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart. Saab TransponderTech AB. Appendices. Project designation. Document title. Page 1 (25)

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart. Saab TransponderTech AB. Appendices. Project designation. Document title. Page 1 (25) Appendices 1 (25) Project designation R5 RIC Document title CONTENTS 2 (25) 1 References... 4 2 Dimensions... 5 3 Connectors... 6 3.1 Power input... 6 3.2 Video I... 6 3.3 Video Q... 6 3.4 Sync... 6 3.5

More information

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Broadcast Devices, Inc. AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web:

More information

RB-DSD8. 8 Channel Silence Switcher. Catalogue

RB-DSD8. 8 Channel Silence Switcher. Catalogue RB-DSD8 8 Channel Silence Switcher 2016 Catalogue RB-DSD8 8 Channel Silence Switcher Category: Synchronisers, Delays & Silence Detectors. Product Function: A multi channel (4 stereo) silence detector which

More information

Ultra-ViewRF 8HD Director Monitor. User Operation Manual

Ultra-ViewRF 8HD Director Monitor. User Operation Manual Ultra-ViewRF 8HD 5.8GHz Wireless Director Monitor User Operation Manual 17.1.2013 v2_7 Video Equipment Rentals - VER 912 Ruberta Avenue Glendale, CA 91201 - U.S.A. Office 818-956-1444 Table of Contents

More information

User Manual MODEL: KKF1500-PCAP. True FLAT P-CAP LCD Monitor. Installation Guide. 15 True FLAT P-CAP Touch LCD Monitor

User Manual MODEL: KKF1500-PCAP. True FLAT P-CAP LCD Monitor. Installation Guide. 15 True FLAT P-CAP Touch LCD Monitor True FLAT P-CAP LCD Monitor User Manual Installation Guide 15 True FLAT P-CAP Touch LCD Monitor MODEL: KKF1500-PCAP i-tech Company LLC TOLL FREE: (888) 483-2418 EMAIL: info@itechlcd.com WEB: www.itechlcd.com

More information

PLAYMATE PROFESSIONAL STEREO 19 MIXER, USB/SD CARD AND BLUETOOTH PLAYER. User Guide and Reference Manual. page 1

PLAYMATE PROFESSIONAL STEREO 19 MIXER, USB/SD CARD AND BLUETOOTH PLAYER. User Guide and Reference Manual. page 1 PLAYMATE PROFESSIONAL STEREO 19 MIXER, USB/SD CARD AND BLUETOOTH PLAYER User Guide and Reference Manual page 1 INTRODUCTION Congratulations and thank you for purchasing the NewHank Playmate mixer. This

More information

NAB 2013 PRODUCT CATALOGUE

NAB 2013 PRODUCT CATALOGUE NAB 2013 PRODUCT CATALOGUE QUAD-SPLIT / MULTI-VIEWERS DOWN UP CROSS CONVERTERS AUDIO MONITORING TEST PATTERN GENERATORS AES VU VU EXTENDED BBC EBU DIN NORDIC ABOUT US Comming Soon DECIMATOR DESIGN (aka

More information

Radio for Everyone...

Radio for Everyone... Radio for Everyone... P R O D U C T I O N O N A I R C O N S O L E Eight dual inputs Built in auto Silence detector 4 USB in/out stereo channels Play out USB control section included AES 3 digital program

More information

7 3G -SDI Monitor w/ Signal Conversion QUICKSTART GUIDE

7 3G -SDI Monitor w/ Signal Conversion QUICKSTART GUIDE What s included x Monitor x AC Adapter x Camera Shoe Mount (SM-0) x DV Battery Plate (Check one) Checked by DV BATTERY PLATES -: Canon 900, Sony L, Panasonic D Battery Plates VX7 c-: Canon E6, Nikon EL,

More information

Neve 8801 Channel Strip User Manual

Neve 8801 Channel Strip User Manual Neve 8801 Channel Strip User Manual 527-358 Issue 7.3 The 8801 is a combined Mic / Line / Instrument Preamp, with Dynamics processing, EQ and Insert point. The Audio Router function provides a user configurable

More information

456 SOLID STATE ANALOGUE TAPE + A80 RECORDER MODELS

456 SOLID STATE ANALOGUE TAPE + A80 RECORDER MODELS 456 SOLID STATE ANALOGUE TAPE + A80 RECORDER MODELS 456 STEREO HALF RACK 456 MONO The 456 range in essence is an All Analogue Solid State Tape Recorder the Output of which can be recorded by conventional

More information

ANALOG RADIO MIXER. Flexible. Affordable. Built To Last.

ANALOG RADIO MIXER. Flexible. Affordable. Built To Last. ANALOG RADIO MIXER Flexible. Affordable. Built To Last. Audioarts AIR-4 A N A L O G R A D I O M I X E R At Audioarts, value engineering is straightforward: Define the features our customers require. Design

More information

LIO-8 Quick Start Guide

LIO-8 Quick Start Guide Metric Halo $Revision: 1051 $ Publication date $Date: 2011-08-08 12:42:12-0400 (Mon, 08 Jun 2011) $ Copyright 2010 Metric Halo Table of Contents 1.... 5 Prepare the unit for use... 5 Connect the LIO-8

More information

AX20. Atlas 19.5" 3G-SDI/HDMI Field and Studio Monitor with 3D LUTs & Scopes. Quick Start Guide. What s Included CHECKED BY

AX20. Atlas 19.5 3G-SDI/HDMI Field and Studio Monitor with 3D LUTs & Scopes. Quick Start Guide. What s Included CHECKED BY AX20 Quick Start Guide Atlas 19.5" 3G-SDI/HDMI Field and Studio Monitor with 3D LUTs & Scopes What s Included 1 x Atlas 19.5" Monitor 1 x AC Adapter 1 x Sunhood CHECKED BY AX20 FRONT 1920 x 1080 19.5 inch

More information

Chameleon Labs Model 7720

Chameleon Labs Model 7720 Chameleon Labs Model 7720 Stereo Compressor Owner s Manual 704 228 th Avenue NE, # 826 Sammamish, WA 98074 206-264-7602 www.chameleonlabs.com Revision C - December, 2007 UNPACKING AND INSPECTION Carefully

More information

Operating Instructions

Operating Instructions Marshall Electronics Broadcast A/V Division Model No. VSW-2200 4-Input Seamless SDI A/V Switcher Operating Instructions Table of Contents 1. Overview... 2. Features.... Package Contents... 4. Specifications...

More information

V4.7 Software Quick Start Guide

V4.7 Software Quick Start Guide V4.7 Software Quick Start Guide INTRODUCTION TO V4.7 The 4.7 software update for the Vi Series includes a major update to the functionality of the Vi4 console in particular, bringing a new level of power

More information

DM1624, DM1612, DM812

DM1624, DM1612, DM812 Installation Guide Hardware and Software DM Series Digital Processors models DM1624, DM1612, DM812 LECTROSONICS, INC. 1 Installation Specific Information Only This guide covers only installation related

More information

INFORMATION TO USER CAUTION RISK OF ELECTRIC SHOCK, DO NOT OPEN

INFORMATION TO USER CAUTION RISK OF ELECTRIC SHOCK, DO NOT OPEN INFORMATION TO USER CAUTION RISK OF ELECTRIC SHOCK, DO NOT OPEN! CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED

More information

RPAN. Router Control Panel

RPAN. Router Control Panel RPAN Router Control Panel Operator s Manual June 00 www.snellwilcox.com Snell & Wilcox Ltd., Southleigh Park House, Eastleigh Road, Havant, Hants, PO9 PE, United Kingdom. For technical assistance contact:

More information

Kramer Electronics, Ltd.

Kramer Electronics, Ltd. Kramer Electronics, Ltd. Preliminary USER MANUAL Models: VM-5ARII, Video Audio Distribution Amplifier VM-20ARII, 1:20 Programmable Video Audio Distributor VM-1411, 1:10 Video/Audio Distributor Contents

More information

LDG M-7600 External Meter for Icom IC-7600

LDG M-7600 External Meter for Icom IC-7600 M-7600 OPERATIONS MANUAL MANUAL REV A LDG M-7600 External Meter for Icom IC-7600 LDG Electronics 1445 Parran Road St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com

More information

D-901 PC SOFTWARE Version 3

D-901 PC SOFTWARE Version 3 INSTRUCTION MANUAL D-901 PC SOFTWARE Version 3 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.

More information

2-Port HDMI Automatic Video Switch - 4K with Fast Switching

2-Port HDMI Automatic Video Switch - 4K with Fast Switching 2-Port HDMI Automatic Video Switch - 4K with Fast Switching Product ID: VS221HD4KA Create a powerful visual experience, with the ability to switch between two 4K video sources seamlessly. This 2-port HDMI

More information