1 User's Guide Balluff GmbH Schurwaldstrasse Neuhausen a.d.f. Germany Phone +49 (0) 71 58/ Fax +49 (0) 71 58/50 10 Servicehotline +49 (0) 71 58/ balluff@balluff.de

2 Content 1 Safety Advisories 1 Safety Advisories... 2 Read this manual before installing in hazards to persons or 1.1 Intended use... 2 the sensor and placing it in equipment. This includes 1.2 Qualified personnel... 2 operation. installation of additional safety 1.3 Use and testing... 2 limit switches, emergency stop 1.4 Validity Intended use switches, and the maintaining of 2 Functional variants... 3 permissible ambient conditions. The BML displacement sensor is BML displacement sensors may 3 Characteristics and installed for use in a machine or not be used in life-saving Function... 4 system. Together with a controller systems, in aircraft, etc. 3.1 Characteristics... 4 (PLC) it comprises a displacement 3.2 Display elements... 4 measurement system and may be 1.4 Validity 3.3 Principle of operation... 4 used only for this purpose. This manual is applicable to 3.4 Interface signals... 4 Unauthorized modifications and displacement sensors of type 3.5 Reference point function... 5 non-allowed use will result in loss BML-S1A...S184/KA Limit switch function...5 of guarantee and warranty. 4 Installation... 6 An overview of the various 1.2 Qualified personnel versions can be found in section 4.1 Distances, tolerances "Versions" (refer to part label). 4.2 Determining orientation... 7 This manual is intended for 4.3 Attach sensor head... 7 technical personnel who are 4.4 Attach isolator... 7 involved in installation and setup. 4.5 Glue tape Installing limit switches Use and testing 5 Wiring Prevailing safety regulations and 5.1 Cable with connector codes must be observed for using 5.2 Cable without connector the displacement sensor. In 5.3 Connecting the sense line particular, measures must be 5.4 Interfaces taken to ensure that a defect in the displacement sensor will not result 6 Startup Check connections Turn on system Check system function Regular checking Malfunction Accessories Limit switch magnets Adapter plate Tape cover Troubleshooting Technical Data Scope of Delivery Versions The CE Mark verifies Emission tests: that our products meet RF Emission the requirements of EN Group 1, Class A+B EC Directive Noise immunity tests: 89/336/EEC (EMC Directive) Static electricity (ESD) EN Severity level 3 and the EMC Law. Testing in our Electromagnetic fields (RFI) EMC Laboratory, which is accredited by DATech for Testing Elec- EN Severity level 3 tromagnetic Compatibility, has Fast transients (Burst) confirmed that Balluff products EN Severity level 3 meet the EMC requirements of Surge the following Generic Standards: EN Severity level 2 Line-induced noise induced by EN (emission) high-frequency fields EN (noise immunity) EN Severity level 3 Magnetic fields EN Severity level 4 2

3 2 Functional variants of the BML-S1A displacement sensor The BML is a non-contacting, incremental displacement measurement system which in addition to a counting function is available with a reference point and limit switch function. All functions are implemented by means of magnetic sensing.the reference position is integrated in the tape, and limit switches can be attached at any desired position. The following table show the functional variants with their possibilities. Cable type Output signal Reference signal Limit switches A/B sin/cos periodic* one none front and rear none Connector type Output signal Reference signal Limit switches A/B sin/cos periodic* one none none * not for versions with analog output System variant 1 Incremental sensors Sensor head Tape with alternating north and south poles Fig. 2-1: Displacement system with incremental sensors System variant 2 Incremental sensors Sensor head Reference point sensor Magnetic reference point Fig. 2-2: Displacement system with incremental and reference point sensors Limit switch sensors Incremental sensors Magnetic reference point System variant 3 Sensor head Reference point sensor Limit switch magnet Fig. 2-3: Displacement system with incremental, reference point and limit switch sensors 3

4 3 Characteristics and function 3.1 Characteristics BML displacement sensors are characterized by: High system accuracy of 10 or 20 µm High resolution of up to 1 µm High traverse speed of up to 10 m/s Position signal in real-time Very good non-linearity (up to max. ±10 µm) Insensitive to shock, vibration, and contamination such as dust and oil Wear- and maintenance-free Rugged Enclosure rating IP 67 per IEC Display elements The digital sensor head has an LED error indicator (front). Flashing indicates that no signals are being output, for example because the distance between sensor head and tape is outside the tolerance. 3.3 Principle of operation The sensing head is attached to the machine member whose position is to be determined, while the magnetic tape is mounted along the direction of travel. The tape contains alternating magnetic north- and south poles. The two incremental sensors in the sensing head measure the magnetic alternating field. As the tape is passed over without contact, the entire underside of the sensor head must always lie above the tape. The two incremental sensors in the sensor head pick up the magnetic periods so that the controller can determine the distance traveled. In order to be able to count knowing the direction of travel, the two incremental sensors are offset to each other. The sinjsoidal output signals from the two incremental sensors are phase-shifted by 90 and 270 respectively and can be interpreted as a sine and cosine signal. 3.4 Interface signals The sensing head can convert the sinusoidal and cosinusoidal signals either into A/B pulses and send them to the controller (RS422), or output the analog sine and cosine signals directly. The digital A/B pulses are interpolated in the sensing head, whereas the analog signals must be interpolated in the controller. The two digital pulses A and B are 90 phase-shifted, with the sign of the phase shift determined by the direction of travel of the sensor (Fig. 3-1). Each edge change from A or B represents a counting step for the period counter (UP/DOWN Signal A Signal B Increment Direction of motion Example counter state B (Cosine) A (Sine) Output voltage forward counter). When Signal A is ahead, the counting state increases, and when Signal B is ahead the count decreases. The controller thus always knows the incrementprecise position without having to periodically poll the sensor (realtime capability). In the case of the analog sine and cosine signals (sin+, sin, cos+, cos ) the controller evaluates the difference in the signal amplitudes and interpolates from the 4 signals the exact position within one period (FIg. 3-2). If there is movement over several periods, the controller also counts the number of periods. Fig. 3-1: Digitized sine and cosine signals with period counter backward Travel µm Fig. 3-2: Signals from sine and cosine sensor with a magnetic period of 2 mm (1 mm pole width) 4

5 3 Function and characteristics (cont.) 3.5 Reference point function The reference position is always required as the starting point for the count for each incremental displacement system. How the reference position is determined depends on the sensor type, the tape and on the controller. In the simplest system the sensing head with the sinusoidal and cosinusoidal sensors can count only the magnetic periods. The tape contains only one track with magnetic north and south poles (Fig. 3-3). In this case the displacement measuring system does not know the absolute position. This is determined by the controller by adding the counted increments. First however the reference position must be determined by a homing move to the reference switch. A sensing head with an additional reference point sensor can output a reference point signal as soon as it reaches the magnetically encoded reference point on the second track of the tape (Fig. 3-4). Then an reference switch is not needed. In another sensing head version a reference point signal is output with each magnetic pole. This signal is repeated every millimeter (periodic reference point). Incremental sensors The tape does not require a second track with a magnetically encoded reference point. In this case an reference switch needs to be used for the selected reference signal. The controller precisely evaluates the reference position when the switch and the reference point signal of the sensing head are active. Therefore the accuracy requirement for this switch is not especially great. Tape without reference point/with periodic reference point Fig. 3-3: Displacement system without reference point and limit switch function Incremental sensors Tape with one reference point Reference point sensor Magnetic reference point Fig. 3-4: Displacement system with reference point function 3.6 Limit switch function When limit switch functionality is needed, sensing heads can be equipped in addition with a limit switch sensor which senses opposite pole permanent magnets at the ends of the measuring range and sends the signals to the controller (Fig. 3-5). The limit switch sensors function then even if the rest of the sensor fails (security function). If the actuation range of the limit switches needs to be longer than their length (20 mm), multiple limit switches of the same type can be mounted in rows. Limit switch sensors Limit switch magnet rear Limit switch magnet front Fig. 3-5: Displacement system with limit switch function Incremental sensors 5

6 4 Installation Important installation notes: The permissible distance and angle tolerances as per Figs. 4-2, 4-3 and 4-4 must be strictly observed. The sensing head may not come in contact with the tape at any point along the travel. Contact must still be avoided if the stainless steel cover (optional) is used. The magnetic tape must not be subjected to strong external magnetic fields. Direct contact with holding solenoids or other permanent magnets must be avoided. The displacement measurement system must be installed in accordance with the specified enclosure rating. Insulator available only for BML-S1A1 red LED (dig. BML only) Fig. 4-1: Dimensional drawing 4.1 Distances, tolerances The following distances and tolerance must be observed when installing the sensing head and tape: The distance (air gap) between sensing head and tape as per Fig. 4-2 The horizontal offset between sensing head and tape as per Fig. 4-3 The angle tolerances as per Fig Any tilt along the longitudinal axis of the sensing head must still maintain the nominal distance to the tape in the center of the head. The two incremental sensors are located there on the underside. Tape Stainless steel tape cover Fig. 4-2: Permissible air gap between sensor head and tape Tape without single reference point Tape with single reference point Fig. 4-3: Permissible horizontal tolerance to right or left Fig. 4-4: Permissible angle tolerances Tape 6

7 4 Installation (cont.) 4.2 Determining orientation The orientation with respect to front, back, right and left is used in the installation description and is critical for correct installation of the sensing head and tape. Starting from the travel direction of the sensing head the orientations are defined in Fig rear left side right side Fig. 4-5: Orientation 4.3 Attach sensor head The sensor head is attached to the moving machine member using its right or left side. Drill two through-holes or threaded holes in the machine member; observe a height tolerance of 0.1 mm. To increase the tolerance, the optional adapter plate with throughholes (p. 13) can be used. The mounting type depends on the housing style: 1. The housing for model BML- S1A2... has two M3 threaded holes. Machine member Fig. 4-6: Threads in sensor head 2. The housing for model BML- S1A1... has two through-holes (4.3 mm) for M4 screws. Tap the M4 threaded holes into the machine member. Machine member Travel direction Reference point front Fig. 4-7: Threads in machine member 4.4 Attach isolator Applies only to BML-S1A1. For more severe EMC demands the sensor head can be installed completely isolated from the machine by using two isolators (Fig. 4-1). Tap two M3 holes into the machine member. Insert the two isolators right and left into the 4.3 mm holes of the sensor head. Fig. 4-8: Isolator Machine memberr Isolator Fig. 4-9: Installing isolator 4.5 Glue tape Note: Attach the tape to the mounting surface parallel to the direction of travel and completely level. Wavy or skewed tapes will affect the measuring accuracy. To prevent linearity deviations, never stretch or compress the tape. Once glued in place, a tape should not be removed (even partially). Strong non-linearity can be expected from any point which has been lifted. Keep magnetized parts away from the tape to avoid non-linear effects. An ambient temperature of 0 to 40 C is recommended for optimum adhesion. For tapes with a reference track, identify the front and rear end so that the tape can be installed appropriately to the count direction of the sensor head. The reference point is visually marked (Fig. 4-5). Installation options (Fig. 4-10): Pos. 1: For normal ambient conditions glue the tape down to a level surface. Optionally the cover band can be glued on for protection. Pos. 2: For harsh ambient conditions embed the tape fully in a somewhat deeper channel so that it does not extend over the top. Optionally the cover band can be glued on for protection. Pos. 3: For harsh ambient conditions embed the tape fully in a somewhat deeper channel and fill with non-magnetizable material (such as adhesives). The fill material can be leveled by lightly sanding. Pos. 4: Attach the tape ends, e.g. rivet or screw down the tape cover. Tape cover Tape Machine Tape cover Tape in a slot Potting material Tape in a slot Attach tape ends Fig. 4-10: Tape installation options 7

8 4 Installation (cont.) Attach mounting aid The mounting aid ensures that the tape can be attached without lateral offset flush with the left side of the sensor head (Fig. 4-13). Even slight deviations from the tolerance values (Fig. 4-3, 4-4) may affect the measurement results. Fig. 4-11: Mounting aid Machine member Use screws to attach mounting aid to right side of sensor head. Machine member Use screws to attach mounting aid to left side of sensor head. Fig. 4-12: Attaching mounting aid Installing the tape Note The tape must always be mounted flush with the left and right side of the sensing head. 1. If desired: Attach the mounting aid to the sensor head (Fig. 4-12). 2. Thoroughly remove any oil, grease, dust, etc. (use acetone or similar) from the mounting surface and allow to dry completely. 3. For tapes with a reference position, identify front and back end: the reference point is visually marked and is located on the right side of the tape in its own track. For the system to function the reference track of the tape must lie on the right side of the sensing head (Fig. 4-5). For tapes with no reference position no front-back orientation is required. 4. Position the sensing head at the back end of the tape (start of the measuring range). 5. Pull back the film from the back end of the tape and lightly attach the tape. 6. Remove another section of film. 7. Move the sensing head a short distance further while aligning the tape flush with the left and right side of the sensing head (Fig. 4-13). 8. Gently press the tape behind the sensing head. Caution! Do not use a hard tool, otherwise the magnetic surface may be damaged! 9. Optional: To protect the tape from mechanical and chemical effects, glue the stainless steel cover in place (details see section 7.3). 10. Remove mounting aid. Apply tape to this surface Machine member flush Mounting aid Machine member right side Sensor head extends approx. 1 mm beyond tape Mounting aid right side Apply to this nose Fig. 4-13: Attach tape flush with left side of sensor head 8

9 4 Installation (cont.) 4.6 Installing limit switches The front and rear limit switch magnets must always be installed on the right side of the sensing head. right side When the limit switch is in a housing, always attach the front magnet with its nose facing back and the rear magnet with its nose facing front. Limit switch magnet rear Limit switch magnet front When the limit switch is not in a housing, attach the rear magnet with the slot to the left of center and the rear magnet with the slot right of center (Fig. 4-14, 4-16). The following applies to both limit switch types: If the E-stop travel exceeds the length of the limit switch magnet, multiple magnets may be installed in a row (Fig. 4-14). The limit switch sensor becomes active as soon as it begins to enter the magnetic field of the limit switch magnet (Fig. 4-15). Limit switch magnet rear: Slot left of center Fig. 4-14: Installing the limit switch magnets Limit switch magnet front: Slot right of center The limit switch becomes active at about this position E-stop travel Travel (measuring area) E-stop travel Fig. 4-15: Travel and E-stop distances for limit switches with and without housing Limit switch glued to machine Maintain distance from mounting surface. Tape Fig. 4-16: Installation example: Limit switch without housing 9

10 5 Wiring Note the following when making electrical connections: The system and the control cabinet must be at the same ground potential. To ensure EMC, which Balluff confirms with the CE Marking, the following instructions must be followed. The cable shield must be grounded on the controller side, i.e., connect to the protection ground. The connection on the sensor side depends on the configuration. For enhanced EMC requirements (e.g., commutator of an electric motor), isolate the sensing head from the machine (Fig. 4-1). When routing the cable between the transducer, controller and power supply avoid proximity to high-voltage lines due to noise coupling. Especially critical are stray coupling caused by AC harmonics (e.g., from phase controls), against which the cable shield offers little protection. Cable length max. 20 m; conductor cross-section min mm 2, max. 0.5 mm 2. Longer cables may be used if their construction, shielding and routing resist external noise fields. Important: In spite of a voltage drop in the line a nominal operating voltage of 5 V ±5% must be ensured (see Section 5.3). 5.1 Cable with connector View of female side of connector BKS-S184-PU- Signal Pin Cable digital analog 1 WH white A A (sin) 2 BN brown /A /A ( sin) 3 GN green B B (cos) 4 YE yellow /B /B( cos) 5 GY gray Z Z 6 PK pink /Z /Z 7 BU blue GND 8 RD red +5 V 5.2 Cable without connector 12-conductor cable with Sense line (measurement line) for preventing voltage drop in the incoming line. Signal Cable digital analog WH white A A (sin) BN brown /A /A ( sin) GN green B B (cos) YE yellow /B /B( cos) GY gray Z Z PK pink /Z /Z BU blue GND RD red +5 V BK black GND Sense VT violet +5 V Sense GYPK gray/pink Limit switch front RDBU red/blue Limit switch rear 5.3 Connecting the Sense line To avoid a voltage drop in the line a regulated power supply with Sense input should be used (Fig. 5-1). If that is not possible or desired, the Sense lines in the 12-conductor cable should be connected parallel to the +5 V and GND line (Fig. 5-2). Power supply Fig. 5-1: Power supply with sense line Power supply Fig. 5-2: Power supply without Sense line Calculating the voltage drop in the line The supply voltage must be 5 V ±5%. The power supply must ensure this voltage and also compensate for the voltage drop in the line. Use the following formula to calculate the voltage drop in the line: U line = R l x l x [n x 3.1/R st ] where: U line = Voltage drop in the line in Volt R l = 0.23 for the cable version BML-...-KA and parallel wiring of the Sense lines with the supply lines (Fig. 5-2) 0.26 for cable with integrated connector BKS-S184-PU l = Cable length in m n = 3, if the reference pulse is processed in the controller 2, if the reference pulse is not processed in the controller R st = Input impedance of the controller in Ohm Sample calculation Under the following conditions: cable length 5 m Reference pulse is evaluated Control input impedance = 120 Ω Resulting voltage drop is: U line = 0.26 x 5 x [3 x 3.1/ ] = V 10

11 5 Wiring (cont.) 5.4 Interfaces Analog incremental measuring system The sensor sends the measured variable to the controller as an analog sine-cosine differential signal with an amplitude of approx. 1 Vpp (peak-to-peak value) in the nominal range. The signalsd remain low-frequence even during rapid movement. To ensure noise-free transmission, the permissible maximum cable length is 20 m. Signal period 360 el. Digital incremental system The sensor transmits the measured variable to the controller as a digital differential voltage signal (RS422). The edge separation A/B corresponds to the resolution of the sensing head. Signal period 360 el. Edge separation Reference pulse Circuit for reference position Depending on the model, the sensor sends either no reference signal, a single reference signal which is magnetically encoded in the tape, or a periodic reference signal (period = 1 mm, width of the reference signal for the digital BML S1Ax-Q = 90 electrical, for the analog BML S1Ax-A = 180 electrical). In the latter case an external reference switch must be attached to the desired reference signal. The accuracy requirements of this switch are not especially high. Note: The reference signals from the limit switch area are not allowed to be processed. Reference mark Fig. 5-3: Analog output signals el. Fig. 5-5: Digital output signals A-channel el. External switch Reference signal for the controller Fig. 5-7: Reference position circuit A-channel B-channel B-channel Reference channel Circuit for limit switches front and back The opposite poled permanent magnets at the ends of the measuring range are each sensed by a limit switch sensor. The sensor has a normally closed function, so that cable break can be detected. Controller Reference channel Fig. 5-6: Following electronics circuit for digital output Fig. 5-8: Limit switch circuit Limit switch front Limit switch rear Rear limit switch Fig. 5-4: Following electronics circuit for analog output Front limit switch Fig. 5-9: Limit switch signals 11

12 5 Wiring (cont.) Relationship between mechanical resolution and max. frequency The controller must be able to count the minimum time-based edge separations shown in the table (note the counting frequency of your controller). Resolution (µm) min. possible edge separation (µs) at selected V max = 1 m/s at selected V max = 10 m/s (V max = 5.2 m/s) Startup 6.1 Check connections Caution! The connections are not protected against polarity reversal or short circuit! Before turning on power, check the connections carefully to prevent components from being destroyed by incorrect connections or overvoltage. 6.2 Turn on system Bear in mind that the system may make an uncontrolled move when first powered up, especially at initial startup and if the displacement sensor is part of a control system whose parameters are not yet set. Therefore be sure that no hazards could result from an unpredictable start. 6.3 Check system function After installing the transducer system or replacing the sensing head, check all functions as follows: 1. Turn on power to the sensing head. 2. Move the sensing head along the entire measuring range. 3. Check whether all signals are output. 4. Check whether the count direction agrees with the direction of travel. If not, reverse connections A and /A. 6.4 Regular checking The functionality of the transducer system and all its associated components should be checked and logged at regular intervals. 6.5 Malfunction If there is any indication that the transducer system is not functioning properly, remove it from service and secure it against unauthorized use (see also Troubleshooting). 12

13 7 Accessories (order separately) 7.1 Limit switch magnets (BML-Z0002) The magnets can be used with or without housing. The through-holes make it easy to precisely install these limit switch magnets. It is fitted with a magnet only on the side facing the sensor. The space-saving magnets can be glued or attached using customersupplied holders. The upper side is marked with a notch. If the E-stop travel exceeds the length of the limit switch magnet, multiple magnets may be installed in a row (for installation see 4.6). The scope of delivery includes: 2 magnets with housing 2 magnets without housing. 7.2 Adapter plate (BML-Z0005) The adapter plate allows you to set the vertical distance from the tape. It can be attached on the left or right of the sensor head. Note: When using the two isolators, insert them directly onto the housing of the sensor head. Then tighten down the adapter plate. Fig. 7-2: Adapter plate 7.3 Tape cover To prevent damage to the tape from things like chips or chemicals, it may be covered with a strip of stainless steel. Note that the permissible air gap between the sensing head and tape is reduced now by the thickness of the cover strip with adhesive film (0.15 mm) (Fig. 4-2). Before adhering the cover strip, thoroughly clean the surface of the tape (acetone, terpentine, mild plastic cleaner, no gasoline). Ship configurations: 1 Tape cover and tape can be ordered together in the appropriate length. See ordering code p The tape cover may be ordered in 3 defined lengths. See ordering code p. 18. Fig. 7-1: Magnets and housing Set distance from sensor head to tape 1. Tighten down the adapter plate to the sensor head. 2. Attach the adapter plate to the machine member. Do now tighten the screws. 3. Insert a gauge (0.1 mm) between the sensor had and tape. 4. Place the sensor head on the gauge and tighten down the adapter plate. 5. Remove the gauge. Machine member Adapter plate Tape Gauge 0.1 mm Fig. 7-3: Height adjustment with adapter plate 13

14 8 Troubleshooting Problem Possible causes Remedy/Explanation The controller is not getting Necessary supply voltage not When turning on the system, the (in places) any information. present LED (digital BML only) must come on briefly. Otherwise check whether voltage is present and the BML is properly connected. The voltage drop is too high (see formula page 10) Lines are not properly connected The system must have a supply voltage olf 5 V ±5%. Check the voltage across the Sense line or check the formula (page 10). Check connections according to the wiring diagrams. The orientation of the tape with respect to the reference point is incorrect. The reference point marking must be located on the right side of the sensor head (Fig. 4-5). Replace tape. The controller is getting no travel The distance between the sensor Adjust the height of the sensor information at certain points. head and tape is (in parts) head. To check, manuall move incorrect. the head over the entire range; the LED should never come on (digital BML only). The magnetic poles of the tape are in parts damaged by strong magnets. The LED will flash in the damaged areas (digital BML only). Replace tape. Limit switches not switching The distance between the limit Check the distance and angle to correctly. switch magnets and sensor head the tape (Figs. 4-14, 4-16) and is incorrect. correct. The limit switch magnets are attached with the wrong side facing the sensor head (wrong polarity) Check position of the limit switch magnets with respect to the travel direction (Fig. 4-15) and correct. Reference point signal is not The orientation of the tape to The reference point marking must output the reference point is wrong. be located on the right side of the sensor head (Fig. 4-5). Replace tape. The linearity deviation lies outside The sensor head is not moving Correctly position the sensor head the tolerance. parallel to the tape (tolerance (Section 4). see Fig. 4-4). The distance between the sensor head and tape is too great. 14

15 9 Technical Data Electrical data Model BML-S1A_-Q Model BML-S1A_-A Output digital RS422 analog 1 Vpp Output signal A-Signal, B-Signal, reference signal Sine, cosine, reference signal Reference signal by type None, one, periodic signal None, one Resolution 1 µm, 2 µm, 5 µm, or 10 µm Processing-dependent Output voltage Differential signal per RS422 1 Vpp Limit switches U max = 28 V, I max = 20 ma, N.C., U max = 28 V, I max = 20 ma, N.C., GND switching (cable break mon.) GND switching (cable break mon.) System resolution Dep. on tape ±10 µm, ±20 µm Depending on tape ±10 µm, ±20 µm Hysteresis 1 to 5 µm 1 to 5 µm depending on air gap max. non-linearity of the pro- ±2 µm Processing-dependent cessing electronics unidirectional max. non-linearity of the overall Depending on tape ±10 µm or Depending on tape ±10 µm or system (sensor head + tape) ±20 µm within any meter ±20 µm within any meter Temperature coefficient 10.5 x 10-6 K x 10-6 K -1 of overall system such as steel Max. traverse speed Depending on model 1 m/s, 10 m/s >10 m/s Reverse polarity protected no no Overvoltage protection no no Operating voltage 5 V ±5% 5 V ±5% Current draw <50 ma + draw of controller <50 ma + draw of controller at 5 V operating voltage Error indicator LED no Shock rating 100 g/6 ms 100 g/6 ms per IEC Continuous shock 100 g/2 ms 100 g/2 ms per IEC Vibration rating 12 g, Hz 12 g, Hz per IEC Ambient conditions Operating temperature Cable version 20 C...80 C 20 C...80 C Connector version 25 C...70 C 25 C...70 C Storage temperature Cable version 30 C...85 C 30 C...85 C Connector version 25 C...70 C 25 C...70 C Enclosure rating per IEC IP67 IP67 Mechanical data Sensor head to tape gap mm mm Housing material Die-cast zinc Die-cast zinc Connection type 8-pin connector or 12-conductor 8-pin connector or 12-conductor cable cable Weight 25 g 25 g 1 Individually determined according to Balluff Factory Standard 15

16 9 Technical Data (cont.) Cable and connector data Cable with connector (BKS-S184...) Cable Typ M9 connector with 8-conductor 12-conductor PU cable, drag chain PU cable, drag chain capable capable Tempeature range, connector C Operating temperature Dynamic C C Fixed C C Cable diameter mm 5.4 ±0.2 mm Cable bending radius Dynamic 80 mm 81 mm Fixed 40 mm 41 mm Tape BML-M Accuracy class ±18 µm Thickness without cover strip 1.75 ±0.05 mm with cover strip 1.90 ±0.05 mm Width 10 mm Length depending on tape type max. 24 m Pole width (distance north-south pole) 1 mm Single reference mark optional max. non-linearity ±8 µm or ±18 µm within any one meter Weight 70 g/m Recommended operating temperature C Chemical resistance Resistant to oils (motor oil, transmission fluid, hydraulic fluid), terpentine, antifreeze, water, kerosene. Not resistant to aromatic and chlorinated hydrocarbons, ketones, inorganic acids 10 Scope of delivery Sensor head Installation aid 2 isolators, BML-S1A1 only Short Guide Cover strip BML-A... Thickness Width Length approx mm (incl. adhesive film) 10 mm Same as tape length, or fixed lengths Limit switch magnet BML-Z0002 Dimensions L x B x H Magnet housing Limit switch magnet 20 x 12 x 7 mm 20 x 2 x 5 mm 16

17 11 Versions Ordering code for sensor head with digital square wave signal RS422 (specs on part label) BML - S1 A 1 - Q 6 1 D - M KA05 (example) Connection type: S184 = Connector KA05 = 5m cable max. traverse speed: 1 = 1 m/s 2 = 10 m/s Limit switches 0 = no limit switch 3 = two limit switches Reference signal 0 = no signal 1 = one signal 2 = periodic signal Pole width 3 = 1 mm Resolution (A/B edge-to-edge) D = 1 µm E = 2 µm F = 5 µm G = 10 µm Output voltage 1 = digital square wave RS422 Operating voltage 6 = 5 V Mounting 1 = Through-hole 4.3 mm 2 = M3 thread 17

18 11 Versions (cont.) Ordering code foe sensor head with sinusoidal analog signal sin/cos 1 Vpp (specs on part label) BML - S1 A 1 - A 6 2 Z - M KA05 (example) Connection type: S184 = Connector KA05 = Cable 5 m max. traverse speed: 9 = >10 m/s Limit switches 0 = no limit switch 3 = two limit switches Reference signal 0 = no signal 1 = one signal Pole width 3 = 1 mm Resolution Z = not relevant Output voltage 2 = analog 1 Vpp Operating voltage 6 = 5 V Output signal A = analog sin/cos Mounting 1 = Through-hole 4.3 mm 2 = M3 thread Ordering code for tape cover without tape BML - A T 0500 (example) Available lengths: 0500 = 5 m 1000 = 10 m 2400 = 24 m Form factor, width 01 = incremental 10 mm wide Ordering code for connector cable (M9) (specs on part label) BKS-S184-PU-05 (example) Cable length: xx = xx m (in this example 5m) Possible cable lengths: 2, 5, 10 m 18

19 11 Versions (cont.) Ordering code for factory assembled tape, optional with cover (specs on packaging) BML - M I A3 - M R 0020 (example) Ordering code for roll tape, without cover (specs on packaging) BML - M I A0 - T R 0000 (example) Reference point position only for single reference signal in head: xxxx = for xxxx cm from rear (in example 20 cm*) 0000 = no reference point or periodic reference point Length in cm: Order length = effective measuring range + 6 cm (here cm) Tape cover: 0 = without tape cover 3 = with tape cover Accuracy class: 4 = 8 µm (overall accuracy ±10 µm) 5 = 18 µm (overall accuracy ±20 µm) Pole width 3 = 1 mm Type I = incremental Form factor 01 = linear, incremental 10 mm wide *Physically the reference point in the example is at approx. 25 cm measured from the start of the tape: 3 cm = front half of the unusable areas of 6 cm +2 cm = distance between incremental and reference point sensor +20 cm = reference point position within the measuring range Reference point position: 0000 = no reference point possible Available lengths: 0500 = 5 m 1000 = 10 m 2400 = 24 m Accuracy class: 4 = 8 µm (overall accuracy ±10 µm) 5 = 18 µm (overall accuracy ±20 µm) Pole width 3 = 1 mm Type I = incremental Form factor 01 = linear, incremental 10 mm wide No E Edition 0601; Specifications subject to change Replaces Edition

BML-M0 _-I -A _-... User's Guide

BML-M0 _-I -A _-... User's Guide BML-M0 _-I -A _-... User's Guide english www.balluff.com 1 Notes to the user 4 1.1 Validity 4 1.2 Symbols and conventions 4 1.3 Scope of delivery 4 2 Safety 5 2.1 Intended use 5 2.2 General safety notes

More information

Magnetic Sensor - Incremental EHP

Magnetic Sensor - Incremental EHP small design: 12 x 13 x 35 mm stainless steel case resolution up to 0,5 μm; hysteresis ± 1μm pole pitch:1; 2 mm output signal: Digital (TTL-RS422) or analog (1 Vpp) direct connection to control / display

More information

ENC - LKE51 - L I B

ENC - LKE51 - L I B ENC-LKE51 Linear Magnetic Encoder FEATURES DESCRIPTION LKE51 ORDERING INFORMATION Resolutions: 5, 10, 25, and 50μm Linear Travel Speed: Up to 16m/s Standard Sensor for Linear and Rotary Axis Gap Clearance

More information

MAGNETIC TAPE. Series MB. incremental scale. Key-Features:

MAGNETIC TAPE. Series MB. incremental scale. Key-Features: MAGNETIC TAPE incremental scale Series MB Key-Features: Content: Technical Data...2 Technical Drawing...3 Electrical Connection...3 Installation Instruction...3 Digital Displays...4 Order Code...5 - Available

More information

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT) MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT) TECHNICAL DATA Measurement taken Position read sampling time (typical) Shock test DIN IEC68T2-27 Vibrations DIN

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

Linear encoders without bearings incremental System for linear motion feedback

Linear encoders without bearings incremental System for linear motion feedback Features Robust magnetic sensing method Output signals A 90 B with index signal Output circuits: HTL/push-pull and TTL/RS422 Resolution up to 5 µm (4-times evaluation) Non-contact, wear-free sensing system

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor Industrial Pressure Transmitter with i²c interface Stainless Steel Sensor Accuracy according to IEC 60770: standard: ± 0. % FSO option: ± 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Digital

More information

DMP 331i / DMP 333i LMP 331 i

DMP 331i / DMP 333i LMP 331 i DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma

More information

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO. DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:

More information

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 339. Pressure Transmitter. with G ¼ flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0. DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output

More information

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01 Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation

More information

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic. DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar

More information

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for

More information

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request

More information

LM10 linear magnetic encoder system

LM10 linear magnetic encoder system RLS merilna tehnika d.o.o. Cesta II. grupe odredov 5 SI-161 Ljubljana - Dobrunje Slovenia T +86 1 57100 F +86 1 5719 E mail@rls.si www.rls.si Installation guide Issue 4, 14 th January 009 LM10 linear magnetic

More information

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation... Li nearenc oder s wi t httlout put Us ermanual Index 1.0 Introduction..........................2 This Manual...........................2 2.0 Safety Summary......................3 Terms in this Manual....................3

More information

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features: HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement

More information

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0.

More information

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE NorthStar brand SERIES HD35R Heavy Duty Encoder Key Features Phased Array Sensor for Reliable Signal Output Rugged Design with Wide-Spaced Oversized Bearings Unbreakable Code Disc up to 5000PPR Improved

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded

More information

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0

More information

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance

More information

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter. Precision Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Version with cooling element accuracy according to IEC 0770: 0. % FSO Precision Pressure

More information

Cylindrical Photoelectric Sensor CY-100 SERIES

Cylindrical Photoelectric Sensor CY-100 SERIES Cylindrical Photoelectric Sensor CY-00 SERIES Listing (2 m cable length type only) Features Wide product range Shape: Standard type Side view type Connector: 2 m cable length type M2 plug-in connector

More information

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features: ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental

More information

Connecting cables NEBS, for sensors

Connecting cables NEBS, for sensors Connecting cables NEBS, for sensors Connecting cables NEBS, for sensors Product range overview Function Version Type code Connection technology (Electrical connection 2) Connecting cable Cable characteristic

More information

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges

More information

NUMERIK JENA. LIA Series. Exposed Linear Encoder. with Signal Control. Mounting Instructions

NUMERIK JENA. LIA Series. Exposed Linear Encoder. with Signal Control. Mounting Instructions NUMERIK JENA LIA Series Exposed Linear Encoder with Signal Control Mounting Instructions 2 LIA Series Note During power-up procedure of the encoder system the level of power voltage and signal lines must

More information

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor LMP Screw-In Transmitter with piezoresistive Stainless Steel Sensor flush diaphragm hydrostatic level measurement of clean, thin fluid media nominal pressure ranges from 0... 40 mbar up to 0... 40 bar

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Slimline Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire: 4... 20 ma

More information

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide Product Information LS 1679 Incremental Linear Encoder with Integrated Roller Guide February 2007 LS 1679 Incremental linear encoder for measuring steps to 5 µm or 1 µm Integrated wear-free roller guide

More information

Rexroth GDS/GDM1.1 Digital Singleturn/Multiturn Encoder

Rexroth GDS/GDM1.1 Digital Singleturn/Multiturn Encoder Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Rexroth IndraControl VCP 20 Rexroth GDS/GDM1.1 Digital Singleturn/Multiturn

More information

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500 Industriefunkuhren Technical Manual IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C37.118 / AFNOR NF S87-500 Module 7628 ENGLISH Version: 02.01-06.03.2013 2 / 20 7628 IRIG-B

More information

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

High Resolution Multicolor Contrast Scanner. Dimensioned drawing Specifications and description KRTM 20 High Resolution Multicolor Contrast Scanner Dimensioned drawing en 01-2011/06 50116669 12mm 20mm 50mm 12-30 V DC 50 / 25 khz We reserve the right to make changes

More information

Displacement Measuring System for Cylinder Series OSP-P

Displacement Measuring System for Cylinder Series OSP-P -SENSOFLEX Displacement for Cylinder Series OSP-P Overview...112 Technical Data SFI-plus...113 Dimensions SFI-plus...114 Order Information...115 111 Sensoflex - Sensoflex Displacement measuring system

More information

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O Characteristics motion servo drive - Lexium 23 - single phase 200...255 V - 1 kw - I/O Main Range of product Product or component type Device short name Complementary Format of the drive Network number

More information

case 5 temperature sensor cosine sensor sine sensor ground + 5V phase 2- phase 2+ phase 1- phase 1+

case 5 temperature sensor cosine sensor sine sensor ground + 5V phase 2- phase 2+ phase 1- phase 1+ Motor Cables Accessories Motor Cables Extension cables tailo for use with Norgren NP Linear Motors are available in two different versions; standard and high flex for the use in trailing chains or cable

More information

MODEL ED32i TTL LINEAR ENCODER

MODEL ED32i TTL LINEAR ENCODER Reliable non-contact measurement Can be used for rotary as well as linear measurements Differential 5V TTL A/B-Quadrature output Error detection like out of range or missing scale Programmable reference

More information

Photoelectrics Through-beam Type PA18C.T..., DC

Photoelectrics Through-beam Type PA18C.T..., DC Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:

More information

Flexible. Fast. Precise. PPU-E Pick & Place Unit

Flexible. Fast. Precise. PPU-E Pick & Place Unit PPU-E Flexible. Fast. Precise. PPU-E Pick & Place Unit Compact 2-axis unit for a faster, flexible running of any curve on one plane. Field of Application For use in clean and slightly polluted environment.

More information

Type SCH94FO. Type SCH94FO. Description

Type SCH94FO. Type SCH94FO. Description Type SCH94FO Hollow Shaft Fiber Optic Encoder - Ø 94 mm Dual Output Option (Digital & Fiber Optic) Fiber Optic Transmission up to 2,000 meters (~ 1.25 miles) No Degradation of Encoder Signal from Electrical

More information

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper

More information

SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR

SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR Description SE22HR is a very high performance hollow shaft encoder; a high resolution is achievable in a small space with a good performance/price

More information

OM2000N INSTALLATION MANUAL

OM2000N INSTALLATION MANUAL OM2000N INSTALLATION MANUAL 2 1 Figure A 1 2 Laser Beam Output Window Power Cable 821001342 (Rev. B) DESCRIPTION The OM2000N oscillating mirror is an accessory for the 2000N family laser scanners: DS2100N,

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

ODW-621. RS-232 Point-to-point applications

ODW-621. RS-232 Point-to-point applications Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to

More information

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features: ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental

More information

Manual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12

Manual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12 R60722.0002 - Index 3 Analog (U/I) Manual Absolute multiturn encoder Order code: 8.M36X1.XXXX.XX12 Order code: 8.M3661R.XXXX.XX12 Order code: 8.M5861.XXXX.XX12 Publisher Kübler Group, Fritz Kübler GmbH

More information

General Specifications

General Specifications General Specifications WG41F11C Compact O Frame GS 14M04B10-20E-Z1 [Style: S1] Overview The WG41F11C Compact O frame is a space-saving frame designed for coating lines of battery electrode sheets. This

More information

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display. ure Sensor DP-100 Series INSTRUCTI MANUAL High-performance Digital Display For use outside Japan MEUML-DP100 V1.1 Thank you for purchasing products from Panasonic Electric Works SUNX Co., Ltd. Please read

More information

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130 Operating Manual (Edition 04/2004) sinamics Line Reactors SINAMICS G130 Contents 1. Safety Information 2 2. General 5 3. Mechanical Installation 6 4. Electrical Installation 8 5. Technical Specifications

More information

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to

More information

Selection matrix for electronic pressure switches

Selection matrix for electronic pressure switches Selection matrix for electronic pressure switches Type / series 0500 050 050 05 050 0570 050 05 05 05 050 05 05 05 055 056 Page 09 09 7 0 5 5 5 5 9 9 9 9 9 9 Technology Measuring cell ceramic / thick-film

More information

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment. Absolute 60-mm-dia. Rotary Encoder A High Accuracy and Durability for Automatic Equipment Stronger shaft and greater durability (120 N in the radial direction and 50 N in the thrust direction) than previous

More information

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151 Compact, rugged housing Many mounting possibilities Status displayed via LED Measuring range indicated via LED Immune to electromagnetic interference Measuring range programmable via Easy Teach Output

More information

Micropulse AR.... Optimized for the Mobile Hydraulics of the Future

Micropulse AR.... Optimized for the Mobile Hydraulics of the Future ... Optimized for the Mobile Hydraulics of the Future General Data Rod Series AR Integrated in cylinders for controlled work processes, safety and productivity Position detection in mobile hydraulics Sensors

More information

Documentation. Magnetic Encoder System (MES) Version: Date:

Documentation. Magnetic Encoder System (MES) Version: Date: Documentation Magnetic Encoder System (MES) Version: Date: 1.1 2016-02-26 Table of content Table of content 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Intended use... 5 1.3 Documentation

More information

Technical data. General specifications. Indicators/operating means

Technical data. General specifications. Indicators/operating means Model Number Single head system Features Sensor head bidirectional and rotatable Function indicators visible from all directions Quick mounting bracket Selectable sound lobe width Programmable Diagrams

More information

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device 3 x cinch/s-video socket Order no. 33 1532 xx USB/3.5 mm audio socket Order no. 33 1539 xx VGA socket Order no. 33 1540 xx VGA socket with screw-in lift terminals Order no. 33 1541 xx High definition socket

More information

Absolute encoders multiturn

Absolute encoders multiturn The Sendix multiturn encoders 5868 and 5888 with CANopen or CANopenift interface and optical sensor technology are the right encoders for all CANopen or CANopenift applications. With a maximum resolution

More information

Sensor technologies Proximity sensors Series ST4. Brochure

Sensor technologies Proximity sensors Series ST4. Brochure Series ST Brochure 2 Series ST ST Sensor, Series ST with cable open cable ends, -pin Sensor, Series ST mm C-slot with cable Plug, M8, -pin 6 Sensor, Series ST mm C-slot with cable Plug, M8, -pin, with

More information

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions

Your Global Automation Partner. Ultrasonic Sensors. Operating Instructions Your Global Automation Partner RU CK40 RU CP40 Ultrasonic Sensors Operating Instructions Contents 2 Hans Turck GmbH & Co. KG T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com Contents 1

More information

SIMPLY PRECISE USER MANUAL LIA SERIES. Optical Linear Encoder with Online Compensation

SIMPLY PRECISE USER MANUAL LIA SERIES. Optical Linear Encoder with Online Compensation USER MANUAL LIA SERIES Optical Linear Encoder with Online Compensation 2 Index 1. Features and Applications... 4 2. Safety... 5 2.1 General Information... 5 2.2 Notes on Legal Requirements... 6 2.3 Notes

More information

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS MUSIUM RESTAURANT SOUVENIR SHOP EXIT LinkRay Modulators 12 V / 24 V Constant-voltage Applications LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE LINK-RAY TM MODULATORS FOR CONSTANT-VOLTAGE APPLICATIONS 186755

More information

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment) OTHER SUNX PRODUCTS SERIES 0 mm Beam Pitch General Purpose Area Sensor Diagnosis Self-diagnosis Test input Interference prevention Wide sensing area of 7 m,60 mm with 0 mm beam pitch Refer to p.9l for

More information

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s dv/dt filter plus Voltage Peak Limiter Safety information 1 General 2 SINAMICS SINAMICS G130 Operating Instructions Mechanical installation 3 Electrical

More information

3 Cleaning. 4 Technical data

3 Cleaning. 4 Technical data EXC+ EXC- Sig- SIG+ SEN- SEN+ 2.4 Attaching cable to the analog board Attaching cable of the weighing cell to the system solution Connect the cable to the appropriate terminal strip of the Ex1 system solution

More information

3500/42E Vibration Monitor

3500/42E Vibration Monitor 3500/42E Vibration Monitor Bently Nevada* Asset Condition Monitoring Description The 3500/42E Vibration Monitor is a 4-channel monitor that accepts input from proximity and seismic transducers, conditions

More information

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Positioning element and aluminium ring not incl. output 25 bit, Gray-coded clock rate: 62.5 KHz 1 MHz Single or multiturn, length

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

NUMERIK JENA NUMERIK JENA LIK 21, 22, 23. Exposed Linear Encoders compact model range. Exposed Linear Encoders compact model range

NUMERIK JENA NUMERIK JENA LIK 21, 22, 23. Exposed Linear Encoders compact model range. Exposed Linear Encoders compact model range NUMERIK JENA 21, 22, 23 Exposed Linear Encoders compact model range Instruction for 1 NUMERIK JENA 21, 22, 23 Exposed Linear Encoders compact model range Instruction for 1 2 2 Content Content 1 Notes of

More information

Material: Weight: IP Rating: Cable: Connector:

Material: Weight: IP Rating: Cable: Connector: Automation / Mini Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 6 mm Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution: Supply Voltage:

More information

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

Electrical connection

Electrical connection Colour sensors Dimensioned drawing en 02-2014/05 50109619-01 12.5mm 60mm 10-30 V DC 6 khz Scanner for colour detection Very short response time 85µs for detection of fast or small objects and marks Direct

More information

R&S ZVA110 Vector Network Analyzer Specifications

R&S ZVA110 Vector Network Analyzer Specifications ZVA110_dat-sw_en_5214-4813-22_cover.indd 1 Data Sheet 04.00 Test & Measurement R&S ZVA110 Vector Network Analyzer Specifications 15.11.2013 14:42:28 CONTENTS Definitions... 3 Specifications... 4 Overview...

More information

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151 Smooth sonic transducer face Cylindrical housing M18, potted Connection via M12 x 1 male Teach range adjustable via pushbutton or adapter Temperature compensation Blind zone: 2.5 cm Range: 40 cm Resolution:

More information

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor With analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation

More information

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Contactless encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED LED indicates measuring range Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024,

More information

Electrical connection

Electrical connection Colour sensors Dimensioned drawing Part No. 50109619 12.5mm 60mm 10-30 V DC 6 khz Scanner for colour detection Very short response time 85µs for detection of fast or small objects and marks Direct indication

More information

R&S ZN-Z85 Switch Matrix Specifications

R&S ZN-Z85 Switch Matrix Specifications R&S ZN-Z85 Switch Matrix Specifications Data Sheet Version 01.02 CONTENTS Definitions... 3 Block diagrams... 4 Specifications... 5 General features... 5 Performance data... 5 Remote control... 5 Switching

More information

part numbers 5 VDC ±5% 5 VDC ±5% 35 ma 30 ma RS 422 3,2 MHz < 4 VDC 160 khz RS 422

part numbers 5 VDC ±5% 5 VDC ±5% 35 ma 30 ma RS 422 3,2 MHz < 4 VDC 160 khz RS 422 Magnetic sensors for rotary applications MDFK 08, 2 channel features competitively priced angular measurement solution using or magnetic rotor 2 channel version channel A/B 90 shifted 8-/16-fold interpolation

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors Differential Sensor Micropressure Sensor with Easy-to-Read Digital Repeat accuracy of ±1% FS (setting resolution: 0.01 kpa), high-precision pressure control available. Compact design (31 mm) saves mounting

More information

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151 Rectangular, aluminium / plastic Versatile mounting possibilities LED indicates measuring range Immune to electromagnetic interferences Extremely short blind zones 12 bit resolution 4-wire, 15 30 VDC Analog

More information

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN Main features Ranges: from: 0...1000 to 0...5000 bar Output signal 4...20mA 2 wires / 0,1...5,1Vdc / 0.1...10.1Vdc / 0...5Vdc / 0...10Vdc

More information

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective

More information

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

R&S RT-Zxx High-Voltage and Current Probes Specifications

R&S RT-Zxx High-Voltage and Current Probes Specifications R&S RT-Zxx High-Voltage and Current Probes Specifications Test & Measurement Data Sheet 14.00 CONTENTS Definitions... 3 Probe/oscilloscope chart... 4 R&S RT-ZH10/-ZH11 high-voltage probes... 5 R&S RT-ZD01

More information

Multifunction Digital Timer

Multifunction Digital Timer Multifunction Digital Timer 72 x72 mm Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.

More information

DRAW WIRE SENSOR. Series MH120 for mobile hydraulics applications. Key-Features:

DRAW WIRE SENSOR. Series MH120 for mobile hydraulics applications. Key-Features: DRAW WIRE SENSOR Series MH120 for mobile hydraulics applications Key-Features: Content: Introduction...2 Technical data...3 Analog outputs...3 Digital output CANopen...4 Electrical connection...4 Technical

More information

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD ATEX II 3 G approval Gases and vapors IIC group, zone 2 Dusts IIIC group, zone 22 When used in Ex areas, the special conditions of the approval must be observed Safety clips to prevent inadvertent detachment

More information