Shock and Vibration Tests on SmartScan Interrogators to ISO :

Size: px
Start display at page:

Download "Shock and Vibration Tests on SmartScan Interrogators to ISO :"

Transcription

1 SENSE THE FUTURE Shock and Vibration Tests on SmartScan Interrogators to ISO : Document Ref: A Document Date: 28/7/22 Prepared by: Approved by: CD, LH CD This information herein is the property of Smart Fibres Ltd and is to be held strictly in confidence by the recipient. No copy is to be made without the written permission of Smart Fibres Ltd. Disclosures of any of the information herein is to be made only to such persons who need such information during the course of their engagement or employment at Smart Fibres Ltd or under the written authority of Smart Fibres Ltd. Any patent applications, patents and/or desi applications, registered desis or copyrights arising from or contained in the information herein, shall be considered the property of Smart Fibres Ltd and as such are subject to the aforementioned obligation of confidence on the recipient. Smart Fibres Ltd 3 Brants Bridge Bracknell RG2 9BG United Kingdom info@smartfibres.com Web: Tel: Fax: Certificate No: LRQ Directors: C Staveley A Melrose Registered in England: VAT Registration No: GB Registered Office: 4 Dedworth Road Windsor Berkshire SL4 5BB United Kingdom

2 Introduction Details of the Standard Method Equipment Used: Results Vibration Tests Shock Tests Summary... 9 Document Revision History: Issue Issue Date Change A 28 th July 22 New document Page 2 28/7/ A

3 INTRODUCTION Subsea Production Control equipment for the oil and gas industry must conform to EN ISO This includes subsea equipment modules (SEMs) such as a SmartScan or SmartScope interrogator packaged in a pressure vessel. Part of the qualification test programme for this standard is shock and vibration testing, to ensure that the equipment is robust enough to stand up to the environment it will see during transportation, handling, installation and operation. Qualification tests may be performed on examples of the component to demonstrate its suitability for the environment. Additionally, Environmental Stress Screening (ESS) tests may be applied to each example of the component to weed out faulty or weak devices.. DETAILS OF THE STANDARD There are two standard qualification tests for electronic equipment. Printed circuit boards (PCBs) and sub-assemblies shall be qualified to standard Q. Modules consisting of a number of PCBs assembled into a rack-type frame shall be qualified to standard Q2. Individual circuit boards in the assembly do not require testing to Q if the whole module is qualified according to Q2. The Equipment Under Test (EUT) must be monitored during all ESS (random vibration testing). Monitoring during swept sine and shock testing is not required but may be preferred. The specifications for Q and Q2 are as follows: Q: Vibration: Shock: Q2: Vibration: Shock: 5 to 25 Hz, +/- 2 mm displacement, then 25 to Hz 5 g acceleration. 3g, ms half sine. 5 to 25 Hz, +/- 2 mm displacement, then 25 to 5 Hz 5 g acceleration. g, ms half sine. The maximum vibration sweep rate is to be one octave per minute. It must be low enough to allow any resonance to build up to maximum amplitude. A double sweep shall be performed from minimum to maximum frequency and back again. There must be no resonance having a mechanical amplification factor of greater than. The full test programme consists of vibration testing along three mutually perpendicular axes and four shocks in each of six directions in the same axes. No siificant damage shall have occurred after shock and vibration tests and the EUT must pass a test of % functionality. 2 METHOD Remove the rubber feet from the bottom of the SmartScan and undo the four tamper-proof screws holding the two halves of the enclosure together. Mount the SmartScan to the test bracket ( A) with countersunk M3 screws passing through the bracket and into the four holes in the bottom of the SmartScan. Use vibration-resistant threadlock if possible and do the screws up firmly. Now mount the bracket to the top plate of the shaker with M6 socket screws. Fit the feedback accelerometer into one of the tapped holes provided in the bracket. Power the SmartScan and connect the Ethernet Lead. Connect test FBGs to all 4 output channels. You may choose to use a drop of threadlock on the FC/APC connectors but take care not to contaminate the mating optical surfaces. The test FBGs must remain stable throughout the test period. Suitable artefacts are athermal FBGs or any standard FBG, kept at a constant temperature (ideally less that C change during the test). Page 3 28/7/ A

4 Available athermal FBG wavelengths are 535, 55 and 565 nm. The test is to be carried out to Q2 as described above. Build up to the specified vibration in steps of, 2.5, 4 and 5 g peak acceleration for example. Record FBG data at khz or more for the whole of each sweep. Take spectra at the beginning and end of each sweep to look for changes in light output, bearing in mind that any change may be due to movement at the front panel connector rather than a fault in the EUT. Pay attention to any sis of mechanical resonance and make notes accordingly. An accelerometer may be fixed to the interrogator casing to record any resonances of the box and perhaps give an indication of any resonances of internal components. Repeat the above steps to do tests in the other axes by using the test brackets: 749-5, , , The SmartScan and the test bracket need to be assembled according to assembly drawing Figure to 3 below shows the SmartScan, mounted to the shaker and test bracket in 3 axes. Note there are always two accelerometers one control accelerometer and one response accelerometer mounted close to the tested instrument. Note further that the optical and Ethernet connectors are not special vibration-resistant types. Figure. SmartScan on the shaker in axis. Figure 2. Smartscan on the shaker in axis 2 Figure 3. Smartscan on the shaker in axis 3 2. EQUIPMENT USED: Electromaetic Shaker: LDS V65 with PA/L amplifier and FPS L field power supply. LDS COMETUSB Shaker Controller, PC running LDS Value software FBGs in athermal packaging, apodised, % reflectivity, half-width <.25 nm Accelerometer DeltaTron 454- (calibrated 29/3/22) Accelerometer 2 DeltaTron (calibrated 2/2/22) Page 4 28/7/ A

5 3 RESULTS 3. VIBRATION TESTS Figures 4, 6 and 8 below are plots of the amplitude of the control and response accelerometer sials vs vibration frequency. Note that the control sials followed the ISO Q2 test specification very closely. Some deviation in the response accelerometer sials were noticed at higher frequencies but the amplitudes of the change was well below the x threshold prescribed by the standard. The outputs of the SmartScan are shown in Figures 5,7 and 9. The test FBGs were scanned at 25 Hz and the data averaged down to Hz to provide a low-noise sial. This makes it easier to see any underlying fluctuations in the interrogator output. The total deviations of measured FBG wavelength from the beginning to the end of the tests were.5 pm. This is less than the unaveraged resolution of the instrument (.8 pm) and well below the operating stability specification of +/- 5 pm input(f) input2(f) Frequency (Hz) Figure 4. Axis, accelerometer frequency response plots. Input 2 is the control accelerometer; input is the response accelerometer. Figure 5. Axis frequency response of athermal test FBGs. Page 5 28/7/ A

6 8.925 input(f) input2(f) Frequency (Hz) Figure 6. Axis 2, accelerometer frequency response plots. Input is the control accelerometer; input 2 is the response accelerometer. Athermal FBG Shift [pm] ch Frequency [Hz] Figure 7. Axis 2 frequency response of athermal test FBGs input(f) input2(f) Frequency (Hz) Figure 8. Axis 3, accelerometer frequency response plots. Input is the control accelerometer; input 2 is the response accelerometer. Page 6 28/7/ A

7 Athermal FBG Shift [pm] ch Frequency [Hz] Figure 9. Axis 3 frequency response of athermal test FBGs. 3.2 SHOCK TESTS Figures, 2 and 4 below are plots of the amplitude of the control and response accelerometer sials vs time. The figures represent one shock pulse that has been repeated four times within 2 seconds. Note that the control sials followed the ISO Q2 test specification very closely. The control sial (shock pulse) has been slowly built up to a maximum of % by performing shocks at 25%, 5% and 75%. The data was logged continuously during all the steps. Some deviations in the response accelerometer sials were noticed due to the system dynamics. The deviations were below those required by ISO s. The outputs of the SmartScan are shown in Figures,3 and 5. The test FBGs were scanned at 25 Hz and the data averaged down to 25 Hz to provide a low-noise sial. This makes it easier to see any underlying fluctuations in the interrogator output. There is a linear shift on tested athermal FBGs due to the ambient temperature change. The total deviations of measured FBG wavelength from the beginning to the end of the tests were.5 pm. This is less than the unaveraged resolution of the instrument (.8 pm) and well below the operating stability specification of +/- 5 pm. There is a linear shift on tested athermal FBGs due to the ambient temperature change Figure. Axis, accelerometer frequency response plots. Input 2 is the control accelerometer; input is the response accelerometer.4 Page 7 28/7/ A

8 Athermal FBG Shift [pm] at % (positive) at % (negative) ch time [s] Figure. Axis athermal test FBGs response Figure 2. Axis 2, accelerometer frequency response plots. Input 2 is the control accelerometer; input is the response accelerometer.4 Athermal FBG Shift [pm] at % (positive) at % (negative) ch time [s] Figure 3. Axis 2 athermal test FBGs response. Page 8 28/7/ A

9 Figure 4. Axis 3, accelerometer frequency response plots. Input 2 is the control accelerometer; input is the response accelerometer.4 Athermal FBG Shift [pm] at % (positive) at % (negative) ch time [s] Figure 5. Axis 3 athermal test FBGs response. 4 SUMMARY The SmartScan interrogator passed a shock and vibration tests performed according to the ISO standard. A small amount of mechanical amplification was recorded by a response accelerometer mounted on the SmartScan enclosure during vibration test. Further work will be performed to discover the source of this effect. Page 9 28/7/ A

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications March 2006 Agilent multi-wavelength meters are Michelson interferometer-based instruments that measure wavelength and optical

More information

Multiple Band Outdoor Block Up- and Downconverters

Multiple Band Outdoor Block Up- and Downconverters Multiple Band Outdoor Block Up- and Downconverters Vertical Mount Option RF IF LO Frequency Frequency Frequency Model Band (GHz) (MHz) (GHz) Number Block Upconverters 1 12.75 13.25 0.95 1.45 11.8 UPB2-WS-13.625

More information

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS Standard Configuration Vertical Mount Option FEATURES Antenna mount, weatherproof to IP-65 Automatic 5/10 MHz internal/external

More information

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications

OPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications OPTICAL SPECTRUM ANALYZER 600 to 750 nm GPIB High Performance for DWDM Optical Communications The is a diffraction-grating spectrum analyzer for analyzing optical spectra in the 600 to 750 nm wavelength

More information

ROBOTEQ, INC. PRODUCT VIBRATION AND SHOCK TESTING of the Motor Controllers and Magnetic Sensor Report No A Proposal No.

ROBOTEQ, INC. PRODUCT VIBRATION AND SHOCK TESTING of the Motor Controllers and Magnetic Sensor Report No A Proposal No. ROBOTEQ, INC. PRODUCT VIBRATION AND SHOCK TESTING of the Motor Controllers and Magnetic Sensor Report No. 228-16-2557A Proposal No. 44763, Revision C Customer Information Roboteq, Inc. Blake Wilson 7898

More information

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS FEATURES Small weather resistant enclosure Automatic 5/10 MHz internal/external reference selection 10/100 Base-T Ethernet and RS-485/RS-422 remote control

More information

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters Data Sheet Agilent multi-wavelength meters are Michelson interferometer-based instruments that measure wavelength and optical power of laser light

More information

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet Agilent multi-wavelength meters are Michelson interferometer-based instruments that measure wavelength and optical power of laser

More information

9070 Smart Vibration Meter Instruction Manual

9070 Smart Vibration Meter Instruction Manual 9070 Smart Vibration Meter Instruction Manual Overall machine and bearing conditions: vibration values are displayed with color coded alarm levels for ISO values and Bearing Damage (BDU). Easy vibration

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

Vibration Measurement and Analysis

Vibration Measurement and Analysis Measurement and Analysis Why Analysis Spectrum or Overall Level Filters Linear vs. Log Scaling Amplitude Scales Parameters The Detector/Averager Signal vs. System analysis The Measurement Chain Transducer

More information

MachineryMate 800 operating guide Handheld vibration meter

MachineryMate 800 operating guide Handheld vibration meter MachineryMate 800 operating guide Handheld vibration meter Wilcoxon Sensing Technologies 20511 Seneca Meadows Parkway, Germantown MD 20876, USA Amphenol (Maryland), Inc d/b/a Wilcoxon Sensing Technologies

More information

High Performance Outdoor Test Translators

High Performance Outdoor Test Translators Input Output LO Frequency Frequency Frequency Model (GHz) (GHz) (GHz) Number RF Transmit-Band to RF Receive-Band 5.85 6.425 3.625 4.2 2.225 DN-WS-6.1/3.9 5.85 6.65 3.4 4.2 2.45 DN-WS-6.25/3.8 6.725 7.025

More information

High-Value 100 Series (Outdoor)

High-Value 100 Series (Outdoor) R Back to Synthesized/Tunable Converters High-Value 100 Series (Outdoor) HIGH-VALUE OUTDOOR COMMUNICATION CONVERTERS Specifications Outline Drawings Phase Noise System Diagram Control Accessories Options

More information

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

High Resolution Multicolor Contrast Scanner. Dimensioned drawing Specifications and description KRTM 20 High Resolution Multicolor Contrast Scanner Dimensioned drawing en 01-2011/06 50116669 12mm 20mm 50mm 12-30 V DC 50 / 25 khz We reserve the right to make changes

More information

HDO701 FIBRE OPTIC TRANSMITTER

HDO701 FIBRE OPTIC TRANSMITTER Timo Rantanen 12.7.2011 1(5) HDO701 FIBRE OPTIC TRANSMITTER HDO701 is a high performance, extremely linear externally modulated 1550 nm transmitter for fibre optic CATV links. This transmitter type has

More information

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17 1/3 RACK-MOUNTED BLOCK CONVERTER Unit shown with Option 17 Unit shown without Option 17 FEATURES Automatic 5/10 MHz internal/external reference selection with a 0.1 Hz nominal bandwidth clean-up loop Gain

More information

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters R Back to Block/Fixed Tuned Converters Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters Ka-BAND OUTDOOR BLOCK AND LOW-NOISE BLOCK Specifications Options Outline Drawings Phase Noise

More information

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change. Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change. Applications Academic/Education Design, development and manufacturing of passive and active

More information

MX1609. Data Sheet. Thermocouple amplifier. Special features. Block diagram. B en

MX1609. Data Sheet. Thermocouple amplifier. Special features. Block diagram. B en MX1609 Thermocouple amplifier Data Sheet Special features 16 inputs Connection of type K thermo couples to mini thermocouple sockets Measuring point identification via RFID Internal cold junction compensation

More information

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS FEATURES Small weather resistant enclosure RS-422/RS-485 and 10/100 Base-T Ethernet remote control Output signal monitor port 30 db gain control Automatic 5/10 MHz internal/external reference selection

More information

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors) More Precision scancontrol // 2D/D laser scanner (laser profile sensors) 1 scancontrol 26x gapcontrol 26x1 Technical details and versions - z-axis measuring up to 265mm - x-axis measuring up to 14.5mm

More information

DVO700 P FIBRE OPTIC TRANSMITTER

DVO700 P FIBRE OPTIC TRANSMITTER Timo Rantanen September 24, 2002 1(5) FIBRE OPTIC TRANSMITTER is a high performance, extremely linear externally modulated 1550 nm transmitter for DVO fibre optic CATV link. This transmitter type has been

More information

Amplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to

Amplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to R Back to Amplifier Systems 1:1, Dual 1:1 and 1:2 Redundant Low-Noise The 1:1, dual 1:1 and 1:2 redundant lownoise amplifier (LNA) systems are designed to ensure continuous operation without disruption

More information

OM2000N INSTALLATION MANUAL

OM2000N INSTALLATION MANUAL OM2000N INSTALLATION MANUAL 2 1 Figure A 1 2 Laser Beam Output Window Power Cable 821001342 (Rev. B) DESCRIPTION The OM2000N oscillating mirror is an accessory for the 2000N family laser scanners: DS2100N,

More information

Specifications. Reference Documentation. Performance Conditions

Specifications. Reference Documentation. Performance Conditions The material in this section is organized into two main groupings: the specification tables and the supporting figures. The specification tables include: 1. PAL general and test signal specifications 2.

More information

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS FREQUENCY CONVERTER MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS FEATURES Small weather resistant enclosure Automatic 5/10 MHz internal/external reference selection 10/100 Base-T Ethernet and RS-485/RS-422

More information

MX1609 T. Data sheet. Thermocouple amplifier Type T. Special features. Block diagram. B en

MX1609 T. Data sheet. Thermocouple amplifier Type T. Special features. Block diagram. B en MX1609 T Thermocouple amplifier Type T Data sheet Special features 16 inputs (electrically isolated) Thermocouple mini type T Measuring point identification Data rate up to 300 Hz 8 internal cold junction

More information

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems R Back to Block/Fixed Tuned Converters 1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems 1:1 1:1 AND 1:2 REDUNDANT LOW- NOISE Ka-BAND BLOCK CONVERTER SYSTEMS Specifications Options 1:1 Diagram

More information

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130 Operating Manual (Edition 04/2004) sinamics Line Reactors SINAMICS G130 Contents 1. Safety Information 2 2. General 5 3. Mechanical Installation 6 4. Electrical Installation 8 5. Technical Specifications

More information

I/A Series Hardware Fiber Optic LAN Converter

I/A Series Hardware Fiber Optic LAN Converter I/A Series Hardware PSS 21H-7F3 B4 The provides bidirectional conversion between coaxial and fiber optic media. The converter is compatible with existing I/A Series system hardware, utilizes industry standard

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 158 2016 Recommended Environmental Condition Ranges for Broadband Communications Equipment NOTICE The Society

More information

MULTIBAND 1/3 RACK-MOUNTED

MULTIBAND 1/3 RACK-MOUNTED BLOCK CONVERTER FEATURES Cover multiple ITU Ku-Band regions and other combinations Automatic 5/10 MHz internal/external reference selection with a 0.1 Hz nominal bandwidth clean-up loop RS-485/RS-422 and

More information

Displacement Measuring System for Cylinder Series OSP-P

Displacement Measuring System for Cylinder Series OSP-P -SENSOFLEX Displacement for Cylinder Series OSP-P Overview...112 Technical Data SFI-plus...113 Dimensions SFI-plus...114 Order Information...115 111 Sensoflex - Sensoflex Displacement measuring system

More information

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B ) SMARTSCAN 8000 PLUS LIGHT CURTAIN 1 Unpacking 8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/0160306 CD206B160306 ) Remove all packaging material and retain it Locate and keep the delivery

More information

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical

More information

Model 4700 Photodiode Characterizer

Model 4700 Photodiode Characterizer Model 4700 Photodiode Characterizer Complete PD Measurement system The 4700 Photodiode Characterizer is a complete photodiode test system. It will characterize PDs or APDs (upcoming) without the need for

More information

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications Durham Magneto Optics Ltd NanoMOKE 3 Wafer Mapper Specifications Overview The NanoMOKE 3 Wafer Mapper is an ultrahigh sensitivity Kerr effect magnetometer specially configured for measuring magnetic hysteresis

More information

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source

Agilent 83437A Broadband Light Source Agilent 83438A Erbium ASE Source Agilent 83437A Agilent 83438A Erbium ASE Source Product Overview H Incoherent light sources for single-mode component and sub-system characterization The Technology 2 The Agilent Technologies 83437A (BBLS)

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) This product is no longer carried in our catalog. AFG 2020 Characteristics Features Ordering Information Characteristics

More information

Model Number Structure

Model Number Structure Cycle Control Units CSM DS_E_7_1 Refer to Safety Precautions for All Power Controllers. Used in Combination with the to Enable High-precision Temperature Control Use cycle control to achieve power control

More information

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio Interface Practices Subcommittee SCTE STANDARD SCTE 119 2018 Measurement Procedure for Noise Power Ratio NOTICE The Society of Cable Telecommunications Engineers (SCTE) / International Society of Broadband

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

WVR500 Waveform/Vector Monitor

WVR500 Waveform/Vector Monitor Service Manual WVR500 Waveform/Vector Monitor 070-8897-01 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are

More information

HDRFI Series Tensolite High-Performance Cable & Interconnect Systems. High Density RF Interconnect

HDRFI Series Tensolite High-Performance Cable & Interconnect Systems. High Density RF Interconnect HDRFI Series Tensolite High-Performance Cable & Interconnect Systems High Density RF Interconnect HDRFI is a patented Tensolite connection system that transfers high frequency signals through a unique

More information

SURFACE MOUNT LED LAMP STANDARD BRIGHT 1206 (Reverse Mount)

SURFACE MOUNT LED LAMP STANDARD BRIGHT 1206 (Reverse Mount) PACKAGE DIMENSIONS TOP 5 0.043 (1.1) 0.126 (3.2) SIDE 0.012 (0.3) 0.079 (2.0) BOTTOM + - POLARITY MARK (See Note 2) for -2, -3, -4 and -B POLARITY for -7 NOTE: 1. Dimensions for all drawings are in inches

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

SATCOM FIBER OPTIC PRODUCTS

SATCOM FIBER OPTIC PRODUCTS INDOOR APPLICATIONS ONE THIRD RACK SATCOM FIBER OPTIC PRODUCTS CARD CAGE RACK OUTDOOR APPLICATIONS DC-POWERED L-BAND C-BAND LNA TABLE OF CONTENTS INDOOR EQUIPMENT Page One third rack links 2 One third

More information

Linear flow control with actuator IFC

Linear flow control with actuator IFC Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20

More information

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor With analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation

More information

LCD MODULE SPECIFICATION

LCD MODULE SPECIFICATION TECHNOLOGY CO., LTD. LCD MODULE SPECIFICATION Model : MI0220IT-1 Revision Engineering Date Our Reference DOCUMENT REVISION HISTORY DOCUMENT REVISION DATE DESCRIPTION FROM TO A 2008.03.10 First Release.

More information

1/3 RACK-MOUNTED BLOCK CONVERTERS

1/3 RACK-MOUNTED BLOCK CONVERTERS AMPLITUDE SLOPE CONTROL Unit shown with option 17 Unit shown without option 17 FEATURES Automatic 5/10 MHz internal/external reference selection with a 0.1 Hz nominal bandwidth clean-up loop Gain control

More information

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical

More information

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT

TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT RDP Customer Document TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT Doc. Ref CD1004L BS EN ISO 9001 Certificate No. FM13141 Affirmed by Declaration of Conformity USA & Canada RDP Electrosense

More information

PCM ENCODING PREPARATION... 2 PCM the PCM ENCODER module... 4

PCM ENCODING PREPARATION... 2 PCM the PCM ENCODER module... 4 PCM ENCODING PREPARATION... 2 PCM... 2 PCM encoding... 2 the PCM ENCODER module... 4 front panel features... 4 the TIMS PCM time frame... 5 pre-calculations... 5 EXPERIMENT... 5 patching up... 6 quantizing

More information

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors) More Precision scancontrol // 2D/D laser scanner (laser profile sensors) 12 scancontrol 29x gapcontrol 29x1 Technical details and versions zaxis measuring up to 265mm xaxis measuring up to 14.5mm Profile

More information

HP 70950B OPTICAL SPECTRUM ANALYZER

HP 70950B OPTICAL SPECTRUM ANALYZER HP 71450B, 71451B, and 71452B Optical Spectrum Analyzers Technical Specifications Spectral Measurements from 600 to 1700 nm HP 70950B OPTICAL SPECTRUM ANALYZER OPTICAL INPUT The HP 71450B, 71451B, and

More information

VGA to DVI Extender over Fiber SET

VGA to DVI Extender over Fiber SET VGA to DVI Extender over Fiber SET Model #: FO-VGA-DVI 2011 Avenview Inc. All rights reserved. The contents of this document are provided in connection with Avenview Inc. ( Avenview ) products. Avenview

More information

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND BENEFITS...

More information

Getting Started with the LabVIEW Sound and Vibration Toolkit

Getting Started with the LabVIEW Sound and Vibration Toolkit 1 Getting Started with the LabVIEW Sound and Vibration Toolkit This tutorial is designed to introduce you to some of the sound and vibration analysis capabilities in the industry-leading software tool

More information

KVANT. Spectrum 1,6W RGB laser system. Product datasheet

KVANT. Spectrum 1,6W RGB laser system. Product datasheet KVANT Spectrum 1,6W RGB laser system Product datasheet SPECTRUM series professional full colour laser system 1. DESCRIPTION Kvant Spectrum is professional laser system with wide range of use, mainly for

More information

SPECIFICATION. Part No. : MA140.A.LB.001

SPECIFICATION. Part No. : MA140.A.LB.001 SPECIFICATION Part No. : MA140.A.LB.001 Product Name : Olympian 2in1 LTE 4G/3G/2G and GPS/GLONASS/GALILEO LTE 698-960/1710-2700MHz 1M RG-316 SMA(M) GPS/GALILEO 1575MHz-Glonass 1602MHz 1M RG-RG-174 SMA(M)

More information

Linear flow controls VFC Linear flow controls with actuator IFC

Linear flow controls VFC Linear flow controls with actuator IFC Linear flow controls VFC Linear flow controls with actuator Product brochure GB 3 Edition 01.16 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 Actuators IC 20 or

More information

Model KT 53 Cooling incubators with thermoelectric cooling

Model KT 53 Cooling incubators with thermoelectric cooling Model KT 53 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the

More information

OpticalProducts. Illuminating Your Network. Testing the World s Networks

OpticalProducts. Illuminating Your Network. Testing the World s Networks OpticalProducts Illuminating Your Network Testing the World s Networks Fibre Optic Testers Ease of use and cost-effectiveness Trend s Family of Optical Products Has Increased The new products include Optical

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 158 2009 Recommended Environmental Condition Ranges for Broadband Communications Equipment NOTICE The Society

More information

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM

CTP10 KEY FEATURES SPEC SHEET COMPONENT TEST PLATFORM COMPONENT TEST PLATFORM Efficiently test passive components in 24/7 operation. Perform single sweep insertion loss and return loss measurements with unprecedented dynamic range, speed and resolution. SPEC

More information

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter Fully compliant to LXI Class C specification General Information Up to 8 power meter channels in a

More information

Latvis Interview Reprint

Latvis Interview Reprint 3 Subjective -vs- Objective Evaluation 5 Introduction to Cables 8 Bill Low 18 Power Line Conditioners 19 Garth Powell 23 Vibration Control Products 25 Michael Latvis 29 Acoustic Treatments 31 Bypass Testing

More information

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT 1995 Metric CSJ 0508-01-258 SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT 1.0 Description This Item shall govern for the furnishing and installation of color Single

More information

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 2004 Specifications CSJ 3256-02-079 & 3256-03-082 SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 1. Description. Furnish and install Fiber Optic Video Data Transmission Equipment

More information

User's Guide to the PROLITE-30B

User's Guide to the PROLITE-30B User's Guide to the PROLITE-30B Optical Fiber Identifier v1.0 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 0 MI2027 (02/12/2014)

More information

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules MTS/T-BERD platform Applications Provisioning and maintenance of ROADM networks Commissioning of DWDM

More information

Ordering details. Approval. Classification

Ordering details. Approval. Classification Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation

More information

PONA 3000 Series Erbium Doped Fiber Amplifier

PONA 3000 Series Erbium Doped Fiber Amplifier PONA 3000 Series Erbium Doped Fiber Amplifier Applications High Performance Supertrunking Links High Power Distribution Networks Fiber Deep Architectures FTTx Networks Features Full Function High Power

More information

APD modules. APD module integrated with peripheral circuits. C12703 series. Selection guide. Block diagram

APD modules. APD module integrated with peripheral circuits. C12703 series. Selection guide. Block diagram APD module integrated with peripheral circuits Features Uses a high sensitivity APD Two types of APDs with different photosensitive areas (φ1.5 mm, φ3. mm) are provided. On-board high sensitivity circuit

More information

VM-100R. 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR

VM-100R. 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR VM-100R 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR OPTIONS Up to four internal programmable audio subcarrier modulators Support full I:N redundant multiformat configurations,

More information

RST INSTRUMENTS LTD.

RST INSTRUMENTS LTD. RST INSTRUMENTS LTD. MEMS Tilt Beam Instruction Manual Copyright 2012 Ltd. All Rights Reserved. Ltd. 11545 Kingston St., Maple Ridge, B.C. Canada V2X 0Z5 Tel: (604) 540-1100 Fax: (604) 540-1005 Email:

More information

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1993 Specifications CSJ 0500-01-117 SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic Video

More information

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s dv/dt filter plus Voltage Peak Limiter Safety information 1 General 2 SINAMICS SINAMICS G130 Operating Instructions Mechanical installation 3 Electrical

More information

Practical considerations of accelerometer noise. Endevco technical paper 324

Practical considerations of accelerometer noise. Endevco technical paper 324 Practical considerations of accelerometer noise Endevco technical paper 324 Practical considerations of accelerometer noise Noise can be defined as any undesirable signal within the measurement chain.

More information

Photovoltaic Module Installation Manual (IEC)

Photovoltaic Module Installation Manual (IEC) Phono Solar Technology Co., Ltd. Add: No. 1 Xinghuo Rd., Nanjing Hi-tech Zone, Nanjing, China Tel: +86 25 5863 8000 Fax: +86 25 5863 8009 E-mail: support@phonosolar.com Website: www.phonosolar.com PHONO

More information

SPECIFICATION. Spec No : VSS-1402-CS603B

SPECIFICATION. Spec No : VSS-1402-CS603B SPECIFICATION Spec No : VSS-1402-CS603B 1. INTRODUCTION 1.1. General This specification covers the design requirements and characteristics required of fiber optic splice closures to be used on fiber optic

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar

More information

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for

More information

MTS/T-BERD Platforms WDMPMD Module

MTS/T-BERD Platforms WDMPMD Module ACTERNA TEST & MEASUREMENT SOLUTIONS MTS/T-BERD Platforms WDMPMD Module Key Features A unique solution combining OSA, PMD, and SA test functions in one plug-in module The most compact PMD/WDM/SA test solution

More information

Photovoltaic Module Installation Manual (IEC)

Photovoltaic Module Installation Manual (IEC) Phono Solar Technology Co., Ltd. Add: No. 1 Xinghuo Rd., Nanjing Hi-tech Zone, Nanjing, China Tel: +86 25 5863 8000 Fax: +86 25 5863 8009 E-mail: support@phonosolar.com Website: www.phonosolar.com PHONO

More information

HSME-C400. Data Sheet. Side-Fire Mono-Color Surface-Mount ChipLED. Features. Description. Applications

HSME-C400. Data Sheet. Side-Fire Mono-Color Surface-Mount ChipLED. Features. Description. Applications Data Sheet HSME-C400 Description The HSME-C400 is a side-emitting surface-mount chipled. This chipled is available in industrial popular package footprint of 3.2 mm 2.55 mm. This product comes with integrated

More information

Variable gain and stable detection even at high gains

Variable gain and stable detection even at high gains MODULE APD module C5 Variable gain and stable detection even at high gains Along with an APD, current-to-voltage conversion circuit, and high-voltage power supply circuit, the C5 contains a microcontroller

More information

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors. Brüel & Kjær Pulse Primer University of New South Wales School of Mechanical and Manufacturing Engineering September 2005 Prepared by Michael Skeen and Geoff Lucas NOTICE: This document is for use only

More information

Precision testing methods of Event Timer A032-ET

Precision testing methods of Event Timer A032-ET Precision testing methods of Event Timer A032-ET Event Timer A032-ET provides extreme precision. Therefore exact determination of its characteristics in commonly accepted way is impossible or, at least,

More information

Introduction. Characteristics (Note 1, 2) Parameters Typical Value Units Conditions

Introduction. Characteristics (Note 1, 2) Parameters Typical Value Units Conditions LMG257-185XTN Introduction 18.5" Sunlight Readable LCD Module The LMG257-185XTN is a 18.5" Sunlight Readable LCD module. The module consists of an AUO M185XTN01.2 TFT color LCD panel and a VHB (very high

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

DATE DESCRIPTION CHANGED BY. CHECKED BY FROM TO A First Release. ZENG LI HUANG YUAN LIANG

DATE DESCRIPTION CHANGED BY. CHECKED BY FROM TO A First Release. ZENG LI HUANG YUAN LIANG PAGE 2 OF 18 DOCUMENT REVISION HISTORY DOCUMENT REVISION DATE DESCRIPTION CHANGED BY CHECKED BY FROM TO A 2010.07.15 First Release. ZENG LI HUANG YUAN LIANG PAGE 3 OF 18 CONTENTS Page No. 1. GENERAL DESCRIPTION

More information

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range Installation Manual Table of Contents Basic Operation...2 CR-R880-BL Block Diagram...2 Technical Specifications...3 Features...4

More information

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body Beta TX Datasheet Beta-TX The Beta-TX is a complete self contained laser diode system which can operate in both CW and modulation modes. The Beta- TX features high speed modulation with a bandwidth of

More information

Applications protects low noise amplifiers and other devices from ESD or input power damage military, hi-rel applications

Applications protects low noise amplifiers and other devices from ESD or input power damage military, hi-rel applications +12 to +3dBm Limiter 5Ω Broadband 3 to 3 MHz Maximum Ratings Operating Temperature -55 C to 1 C Storage Temperature -55 C to 1 C RF Power 2W Permanent damage may occur if any of these limits are exceeded.

More information

GFT Channel Digital Delay Generator

GFT Channel Digital Delay Generator Features 20 independent delay Channels 100 ps resolution 25 ps rms jitter 10 second range Output pulse up to 6 V/50 Ω Independent trigger for every channel Fours Triggers Three are repetitive from three

More information

DA E: Series of Narrowband or Wideband Distribution Amplifiers

DA E: Series of Narrowband or Wideband Distribution Amplifiers DA1-150-10-E: Series of Narrowband or Wideband Distribution Amplifiers Key Features Dual A and B inputs. Automatic or manual switchover, configured by the Ethernet port. 1-150 MHz wideband operation. Other

More information

More Precision. confocaldt // Confocal chromatic measuring system

More Precision. confocaldt // Confocal chromatic measuring system More Precision confocaldt // Confocal chromatic measuring system Confocal chromatic sensors for displacement and thickness confocaldt IFS206 / IFS207 IFS206-/VAC(001) IFS206-/VAC(001) IFS206/90-/VAC(001)

More information