Withdrawn Document. Title of Rule Book SECTION N SINGLE LINE WORKING. Page Date Index

Size: px
Start display at page:

Download "Withdrawn Document. Title of Rule Book SECTION N SINGLE LINE WORKING. Page Date Index"

Transcription

1 Uncontrolled Railway When Group Printed Standard Title of Rule Book : GO/RT3000 : Master SECTION N SINGLE LINE WORKING Page Date Index Page No. Latest Issue N.1/N.2 December 2002 N.3/N.4 December 2002 N.5/N.6 December 2002 N.7/N.8 August 1999 N.9/N.10 August 1999 N.11/N.12 December 2002 N.13/N.14 December 2002 N.15/N.16 August 1999 N.17/N.18 December 2002 N.19/N.20 August 1999 N.21/N.22 December 2002 N.23/N.24 December 2002 N.25/N.26 August 1999 N.27/N.28 August 1999 N.29/N.30 August 1999 N.31/N.32 August /2002 Master Rule Book Page N.1

2 N.33/N.34 Uncontrolled When August Printed 1999 N.35/N.36 August 1999 N.37/N.38 August 1999 N.39/N.40 August 1999 N.41/N.42 August 1999 Page N.2 Master Rule Book 12/2002

3 Uncontrolled When Printed CONTENTS (The Contents of this Section N are included in Personalised Rule Books 3, 4, 5, 6, 7, 9 and 10 as shown below. Section N does not, however, apply to persons acting as a Shunter in Personalised Rule Books 6 and 7 but only to Guards) 1. PRINCIPLE (PRB 3, 4, 5, 6, 7, 9 and 10) N.7 2. METHOD N Appointment of a Pilotman (PRB 3, 4, 5, 6, 7, 9 and 10) N Identification of the Pilotman (PRB 3, 4, 5, 6, 7, 9 and 10) N Single Line Working forms (PRB 3 and 9) N Securing points which become facing (PRB 3, 4, 9 and 10) N Control of movements in the right direction over N.8 the single line (PRB 3, 4, 9 and 10) 2.6 Control of movements in the wrong direction N.8 over the single line (PRB 3, 4, 9 and 10) 2.7 Single Line Working tickets (PRB 3, 4, 9 and 10) N Protection of engineering work affecting the single linen.10 (PRB 3 and 9) 2.9 Withdrawal of Single Line Working (PRB 3, 4, 9 and 10) N.10 X. DUTIES OF SIGNALLERS, THE PILOTMAN, N.11 DRIVERS AND GUARDS X.1 Setting up Single Line Working N.11 12/2002 Master Rule Book Page N.3

4 X.1.1 Arrangements Uncontrolled between the Signaller When Printed and the N.11 Pilotman (PRB 3 and 9) X.1.2 Completing the Single Line Working forms (PRB 3 and 9) N.12 X.1.3 Arrangements to be made by the Pilotman N.12 (PRB 3, 4, 9, and 10) X.1.4 Arrangements to be made by the Signaller (PRB 3 and 9) N.17 X.1.5 When arrangements are complete (PRB 3 and 9) N.18 X.2 During Single Line Working N.19 X.2.1 Pilotman's authority for movements to enter the N.19 single line (PRB 3, 4, 5, 6, 7, 9 and 10) X.2.2 Worked points not fitted with a facing point lock N.19 (PRB 3a) X.2.3 Pilotman's instructions to Drivers (PRB 3, 4, 9 and 10) N.20 X.2.4 Completion of Driver's Single Line Working ticket N.21 (PRB 3, 4, 9 and 10) X.2.5 Train worked by two or more locomotives (PRB 3b, 4, N.22 9 and 10) X.2.6 Driver's advice to the Guard (PRB 3b, 4, 5, 6, 7 and 9) N.22 X.2.7 Warning everyone on or near the line (PRB 3b and 9) N.22 X.2.8 Passing a signal at Danger (PRB 3 and 9) N.22 X.2.9 Pilotman to ride with the Driver (PRB 3, 4, 9 and 10) N.22 X.2.10 Pilotman arriving at the end of the single line N.23 (PRB 3 and 9) Page N.4 Master Rule Book 12/2002

5 X.2.11 Intermediate signal boxes (PRB 3 and 9) N.23 Uncontrolled When Printed X.2.12 Checking points which have been secured (PRB 3b and 9) N.23 X.2.13 If the Pilotman is relieved (PRB 3 and 9) N.24 X.2.14 If the Signaller is relieved (PRB 3 and 9) N.24 X.2.15 Speed restrictions (PRB 3 and 9) N.24 X.3 Observance of signals N.25 X.3.1 Trains working over the single line in the right N.25 direction (PRB 4 and 10) X.3.2 Trains working over the single line in the wrong N.25 direction (PRB 4 and 10) X.4 Movements over the Single Line N.26 X.4.1 First train over the single line (PRB 4 and 10) N.26 X.4.2 All movements over the single line (PRB 4 and 10) N.26 X.4.3 Movements over the single line in the right direction - N.26 Passing a signal at Danger (PRB 3b, 4, 9 and 10) X.4.4 Movements over the single line in the wrong direction N.26 (PRB 3b, 4, 9 and 10) X.4.5 Disposal of the Driver's Single Line Working ticket N.27 (PRB 3b, 4, 9 and 10) X.5 Failure of a train on the Single Line N.27 X.5.1 When the Pilotman is on the train (PRB 3, 4, 9 and 10) N.27 X.5.2 When the Pilotman is not on the train (PRB 3, 4, 9 and 10) N.28 X.6 Withdrawal of Single Line Working N.28 12/2002 Master Rule Book Page N.5

6 X.6.1 Action the Pilotman Uncontrolled must take When (PRB Printed 3 and 9) N.28 X.6.2 Resumption of normal working (PRB 3 and 9) N.29 X.7 Single Line Working on Track Circuit Block N.30 lines where there are more than two running lines and all lines in one direction are blocked X.7.1 Method (PRB 3, 4, 5, 6, 7, 9 and 10) N.30 X.7.2 Authority for wrong direction movements (PRB 3, 4, 9 N.31 and 10) X.7.3 Where conflicting movements can be avoided N.31 (PRB 3, 4, 9 and 10) X.7.4 Where conflicting movements cannot be avoided N.32 (PRB 3, 4, 9 and 10) X.7.5 Single Line Working forms/tickets (PRB 3, 4, 9 and 10) N.34 X.7.6 Protection arrangements (PRB 3, 4, 9 and 10) N.34 X.7.7 Special working arrangements (PRB 3, 4, 9 and 10) N.34 X.8 Working of trains to and from the point of obstruction N.34 X.8.1 Trains to run over one line only (PRB 3, 4, 5, 6, 7, 9 and 10) N.34 X.8.2 Method of working (PRB 3, 4, 9 and 10) N.34 Example of Pilotman's Single Line Working form N.36 (RT3191/1) (PRB 3 and 9) Example of Signaller's Single Line Working form N.38 (RT3192/1) (PRB 3 and 9) Example of Driver's Single Line Working ticket N.40 (RT3193/1) (PRB 3, 4, 9 and 10) Page N.6 Master Rule Book 12/2002

7 1. PRINCIPLE Uncontrolled When Printed 1.1 Single Line Working by Pilotman must be introduced when engineering work or an obstruction results in one line of a double line becoming blocked and it is necessary that ALL trains travelling in EITHER direction pass over the one remaining line. (Single Line Working is not necessary if the one remaining line is bi-directional). 1.2 A Pilotman must be appointed to take charge of the Single Line Working. 1.3 The Pilotman must:- be present to authorise ALL movements which require to enter or foul any portion of the single line, unless the Rules in this Section N permit the Signaller to authorise the movement instead ask the Signaller for permission before authorising the movement 2. METHOD 2.1 Appointment of a Pilotman A competent person must be appointed by the local Railtrack Production Manager to act as Pilotman The local Railtrack Production Manager must make sure that a Pilotman's armlet and Single Line Working forms and tickets are available for use at signal boxes and other appropriate locations. 2.2 Identification of the Pilotman The Pilotman must:- wear on the left arm, an armlet with "Pilotman" on it in white letters on a red background Master Rule Book Page N.7

8 if an armlet Uncontrolled is not immediately When available, Printedwear in the same position a red flag until an armlet is provided 2.3 Single Line Working forms The Pilotman must complete a Pilotman's Single Line Working form (RT3191/1 - see example on pages N.36 and N.37) which will detail the Single Line Working arrangements The Signaller must complete a Signaller's Single Line Working form (RT3192/1 - see example on pages N.38 and N.39) which must be dictated by the Pilotman. 2.4 Securing points which become facing (See details in clause X.1.3(c)) 2.5 Control of movements in the right direction over the single line Signals on the unobstructed line must as far as is practicable be worked normally for right direction movements. (See also Diagrams 1N and 2N on pages N.14 and N.15) Right direction movements over any AHB level crossing which is under local control must be controlled by handsignals. 2.6 Control of movements in the wrong direction over the single line Signals on the obstructed line must be disregarded. Instead, all movements in the wrong direction must be controlled by handsignals as follows:- (See also Diagrams 1N and 2N on pages N.14 and N.15) Page N.8 Master Rule Book

9 Uncontrolled When Colour Printed of Proceed Handsignal Location that the Driver must be given Opposite the signal protecting the crossover where trains return to the proper line On an Absolute Block line, opposite the home signal which is worked from the same signal box that also controls the crossover where trains return to the proper line Opposite any other signal where trains might be required to stop At an AHB level crossing which is under local control At a CCTV or RC level crossing where an Attendant is NOT appointed At any other manned level crossing protected by signals At any manned level crossing protected by signals where the handsignal is displayed opposite the signal protecting the level crossing At any manned level crossing protected by signals where the normal position of the barriers or gates is across the roadway At an intermediate signal box unless it is closed YELLOW * YELLOW * YELLOW GREEN NO HANDSIGNAL will be given GREEN YELLOW NO HANDSIGNAL must be given YELLOW * Only if a Handsignaller is provided Master Rule Book Page N.9

10 2.6.2 Shunting signals Uncontrolled and position When light Printed signals must be worked normally, where practicable, to control wrong direction movements. 2.7 Single Line Working tickets The Pilotman must give the Driver of each train requiring to enter or foul the single line a completed Driver's Single Line Working ticket (RT3193/1 - see example on pages N.40 and N.41) unless the train is to enter an obstructed section to:- assist a failed train, or remove a portion of a divided train 2.8 Protection of engineering work affecting the single line When it is necessary to protect engineering work which is affecting the single line, the Protection Controller (PC) or Controller of Site Safety (COSS) must:- carry out the appropriate instructions in Section T (Part ii) arrange for the attendance of any Handsignallers who are required 2.9 Withdrawal of Single Line Working The Pilotman is the only person who can authorise Single Line Working to be withdrawn The Pilotman can authorise Single Line Working to be withdrawn before the obstructed line is clear in the following circumstances:- the arrangements to do so have been published, or the Pilotman is given permission to do so by the local Railtrack Production Manager Page N.10 Master Rule Book

11 X. DUTIES Uncontrolled OF SIGNALLERS, When PrintedTHE PILOTMAN, DRIVERS AND GUARDS X.1 SETTING UP SINGLE LINE WORKING X.1.1 X X Arrangements between the Signaller and the Pilotman The Pilotman and each Signaller concerned must before Single Line Working starts:- reach a clear understanding with each other about the arrangements that are to apply agree a time at which the Pilotman must complete the Pilotman's Single Line Working form The Signaller must remind the Pilotman of the presence of any of the following if they will be affected by the Single Line Working:- (a) (b) (c) (d) (e) (f) manned level crossings which are protected by signals automatic level crossings barrow or foot crossings with white light indications unworked points intermediate signal boxes which are closed any temporary or emergency restrictions of speed that apply on the single line or will effect any train returning to the proper line The Signaller must also tell the Pilotman if the obstructed line is protected in accordance with Section T (Part ii) or is under possession in accordance with Section T (Part iii). X The Pilotman must ask the Signaller:- the time at which the Signallers change duty the time at which any intermediate signal box which is closed will open 12/2002 Master Rule Book Page N.11

12 X.1.2 X X X X Withdrawn Document Completing the Uncontrolled Single Line When Working Printed forms The Pilotman must complete and sign the Pilotman's Single Line Working form:- at the time that was agreed with the Signaller, and provided the line over which the Single Line Working is to apply is clear When the Single Line Working form has been completed, the Pilotman must dictate it to:- the Signaller controlling each crossover between which Single Line Working is to apply the Signaller at any intermediate signal box which is open Each Signaller must then complete a Signaller's Single Line Working form at the Pilotman's dictation. When the form has been completed, each Signaller concerned must:- enter the Pilotman's name on the form read back the completed form to the Pilotman. This enables the Pilotman to be sure that the correct details have been entered on the form by the Signaller record the details in the Train Register The Pilotman must then record the name of each Signaller on the Pilotman's form. X.1.3 Arrangements to be made by the Pilotman After the Single Line Working forms have been dictated, the Pilotman must undertake the following:- (a) Protection arrangements The Pilotman must make sure there is room for trains to draw forward/set back at each end of the single line, clear of any necessary protection on the obstructed line. Where necessary, additional protection must be provided as shown in the table below:- Page N.12 Master Rule Book 12/2002

13 Where drawing Uncontrolled forward/setting When back Printed movements are required at either end of the single line Circumstance Failed train on the obstructed line occupying the same signal section as the crossover at either end The obstructed line is under possession in accordance with Section T (Part iii) Protection of the obstructed line in accordance with Section T (Part ii) is provided in the same signal section as the crossover at either end Emergency protection of the obstructed line is provided in accordance with Section B (Part iii) or M (Part i) The obstruction on the obstructed line is in the same signal section as the crossover and is protected only by the signal Requirements Pilotman to check there is room for trains to draw forward/set back Pilotman to check there is room for trains to draw forward/set back clear of the protection, (if necessary the position of the protection must be adjusted) Single Line Working not permitted Pilotman to check there is room for trains to draw forward/set back clear of the detonators (if necessary the position of the detonators must be adjusted). At the exit end, a hand danger signal must be placed on ground in the "four foot" sufficiently clear to enable trains to set back A hand danger signal must be placed on the ground in the "four foot" sufficiently clear to enable trains to draw forward/set back (b) Arrange for Handsignallers The Pilotman must arrange for Handsignallers to be positioned at the following locations to display a handsignal to all trains travelling over the single line in the wrong direction:- opposite the signal which applies to the obstructed line protecting the crossover over which trains will 12/2002 Master Rule Book Page N.13

14 return Uncontrolled to the proper When line, or Printed on an Absolute Block line, opposite the home signal that is worked from the same signal box that controls this crossover. It is, however, not necessary to position a Handsignaller at either of these locations provided the Pilotman travels with every train over the single line in the wrong direction. This method of working is not permitted during fog or falling snow opposite any other signal on the obstructed line at which trains might be required to stop (See also Diagrams 1N and 2N on pages N.14 and N.15) The Pilotman must tell each Handsignaller to carry out the instructions contained in Section F (Part ii) clause EXAMPLE OF TYPICAL SINGLE LINE WORKING ARRANGEMENTS TRACK CIRCUIT BLOCK LINE (THIS DIAGRAM MUST BE READ IN CONJUNCTION WITH THE TEXT) UP KS200 KS202 KS204 KS206 KS208 KS210 LINE BLOCKED DOWN SINGLE LINE KS201 KS203 KS205 KS207 Handsignaller * (positioned opposite signal KS208) KS209 * Handsignaller is not necessary if Pilotman accompanies every train over the Single Line in the wrong direction Controlled signals to be maintained at danger:- KS200 KS208 Controlled signals to be worked where possible:- KS209 KS203 DIAGRAM 1N Page N.14 Master Rule Book 12/2002

15 Uncontrolled When Printed EXAMPLE OF TYPICAL SINGLE LINE WORKING ARRANGEMENTS ABSOLUTE BLOCK LINE (THIS DIAGRAM MUST BE READ IN CONJUNCTION WITH THE TEXT) 'RT' Signal Box 'RB' Signal Box UP RT1 RT2 RT3 RB4 LINE BLOCKED RB5 RB6 DOWN SINGLE LINE RT4 RB1 RT6 RT5 RB3 RB2 Handsignaller * (positioned opposite signal RB5) * Handsignaller is not necessary if Pilotman accompanies every train over the Single Line in the wrong direction Stop signals to be maintained at danger:- RT3, RB5 Distant signals to be maintained at caution:- RT1, RB1, RB4 Signals to be worked where possible:- RB2, RB3, RB6, RT2, RT4, RT5, RT6 DIAGRAM 2N (c) Securing of points The Pilotman must:- (i) make sure any UNWORKED points on the single line:- are secured and padlocked so that movements over them can be made safely (ii) have a green flag or green light placed alongside them which is clearly visible to the Driver of each train travelling over the single line in the wrong direction make sure any WORKED points are secured and padlocked for the safety of movements over them if:- Master Rule Book Page N.15

16 Uncontrolled they are controlled When by Printed an intermediate signal box which is closed, and they are facing to trains travelling over the single line in the wrong direction (iii) (iv) This must be done even if the points are fitted with a facing point lock. secure any facing points which the Signaller additionally requires to be secured for the safety of movements over them that:- are worked or released from the signal box, and are not fitted with a facing point lock, and are remote from the signal box take possession of and retain the keys to all padlocks that have been used to secure points If any points have been secured by other than the Pilotman, the Pilotman must personally check to see that these points have been properly secured before the first train passes over them in the facing direction. (d) (e) The Pilotman may do this while accompanying the first train over the single line and must therefore tell the Driver to stop the train at each set of points so that he/ she can check they have been properly secured before the train passes over them. Disconnection of track circuit controls The Pilotman must find out if any track circuits require to be disconnected, and if they do, instruct the Signaller concerned to complete and issue form RT3186 to the Signal Technician. Platform working at stations The Pilotman must tell the person in charge of any station where the platform working will be affected by Single Line Working of the revised arrangements. Page N.16 Master Rule Book

17 (f) (g) (h) Withdrawn Document Persons Uncontrolled working When on or Printed near the line The Pilotman must tell everyone who is working on or near the line:- that Single Line Working is to be introduced the line over which it will apply The Pilotman must undertake to do this personally if travelling on the first train over the single line. If not accompanying the first train, the Pilotman must ask the Driver to tell everyone working on or near the line. Advising Crossing Keepers The Pilotman must make sure that any Crossing Keeper who will be affected is told:- of the Single Line Working arrangements that are to apply of the arrangements for the working of block indicators (where they are provided) The Pilotman may do this while accompanying the first train over the single line. Speed restrictions The Pilotman must find out whether there are any temporary or emergency speed restrictions that apply on the single line or will affect any train returning to the proper line. X.1.4 X Arrangements to be made by the Signaller The Signaller must make sure that:- (a) an Attendant takes duty at:- an AHB level crossing which is not provided with wrong direction controls any CCTV or RC level crossing, except where otherwise authorised in Signalbox Special Instructions 12/2002 Master Rule Book Page N.17

18 (b) (c) (d) Withdrawn Document any worked Uncontrolled points not When fitted with Printed a facing point lock at, or released from, the signal box, and which do not need to be operated while Single Line Working is in operation, are secured for the safety of facing movements. The Signaller can ask the Pilotman to arrange to have these points secured if the points are remote from the signal box when train movements require to be made on the obstructed line:- movements to or from a possession are made in accordance with Section T (Part iii) any wrong direction movement of a failed or assisting train is made in accordance with Section D the Pilotman is aware of any temporary or emergency speed restrictions that apply on the single line or will affect any train returning to the proper line X The Signaller must tell the Pilotman when all of the arrangements in clause X have been completed. X.1.5 X X X X When arrangements are complete The Pilotman must make sure all of the requirements contained in clause X.1 are complete before authorising the first train to travel over the single line in the wrong direction. The Pilotman must tell each Signaller:- when all the arrangements to introduce Single Line Working are complete the precise location of each Handsignaller The Signallers must then write the following below the Single Line Working entry made in the Train Register:- "Single Line Working started at...(time)." Single Line Working may then start. Page N.18 Master Rule Book 12/2002

19 X.2 DURING Uncontrolled SINGLE LINE When WORKING Printed X.2.1 Pilotman's authority for movements to enter the single line The Pilotman must:- be present to personally authorise all movements which require to enter, or foul the single line ask the Signaller who controls the entrance to the single line for permission before authorising the movement The Driver must ONLY enter the single line if the personal authority of the Pilotman has been obtained. Exception :- The Signaller can authorise a movement to enter or foul the single line without the Pilotman being present if any of the following apply:- (a) (b) (c) a train is to enter the single line in order to assist a failed train. The Signaller must ask the Pilotman for permission before authorising the movement a train is to pass through a trailing crossover which is in rear of the obstruction a train is to pass to or from an unaffected route at a junction at the end of the single line section. For these movements:- signals may be worked normally the Driver does not need to be told that Single Line Working is in operation X.2.2 Worked points not fitted with a facing point lock The Signaller must arrange for worked points that are not fitted with a facing point lock at, or released from, the signal box to be secured before authorising a movement over them in the facing direction. Master Rule Book Page N.19

20 X.2.3 X Withdrawn Document Pilotman's instructions Uncontrolled to Drivers When Printed Before authorising a train to enter the single line in either direction, the Pilotman must:- (a) (b) tell the Driver over which line Single Line Working applies between which crossovers Single Line Working applies If there is more than one crossover at either end of the section, the Pilotman must make sure the Driver clearly understands which crossover is being used for Single Line Working instruct the Driver to pass over any AHB level crossing which is under local control only if authorised by a proceed handsignal displayed at the crossing In addition, before authorising a train to travel over the single line in the wrong direction, the Pilotman must:- (c) tell the Driver:- whether a Handsignaller has been provided to control wrong direction movements back to the proper line. If this Handsignaller has not been provided, the Pilotman must travel with the Driver and remind the Driver of the location of the crossover where trains are being returned to the proper line (d) the precise locations where Handsignallers are positioned to control wrong direction movements to pass a Handsignaller only if a proceed handsignal is being displayed instruct the Driver to approach cautiously a CCTV or RC level crossing at which no Attendant has been appointed and not pass over it until satisfied that it is safe to do so. The Pilotman must include this requirement on the Driver's Single Line Working Ticket Page N.20 Master Rule Book

21 (e) (f) (g) (h) Withdrawn Document instruct Uncontrolled the Driver When to pass Printed over any other manned level crossing:- which is protected by signals only if authorised by a handsignal displayed at the crossing, or at which the normal position of the barriers or gates is across the roadway, only if the Driver is satisfied that the crossing is closed to road traffic instruct the Driver to stop short of any level crossing with miniature red/green warning lights and to:- sound the horn pass over the crossing only if it is safe to do so This will not apply at crossings which are fitted with wrong direction controls instruct the Driver to pass over any barrow or foot crossing with white light indications only if it is safe to do so This will not apply at crossings which are fitted with wrong direction controls remind the Driver about any of the following:- the presence of any unworked points temporary or emergency speed restrictions intermediate signal boxes which are closed X The Driver must make sure that all of these instructions given by the Pilotman are clearly understood. X.2.4 Completion of Driver's Single Line Working ticket The Pilotman must hand the Driver a completed Driver's Single Line Working ticket after all of the necessary instructions have been given to the Driver, unless the train is to enter an obstructed section to:- assist a failed train, or remove a portion of a divided train 12/2002 Master Rule Book Page N.21

22 X.2.5 X.2.6 X X Withdrawn Document Train worked Uncontrolled by two or more When locomotives Printed If the train is worked by two or more locomotives, the Pilotman must:- give the necessary instructions concerning the Single Line Working arrangements to the Driver of each locomotive show the completed Driver's Single Line Working ticket to each Driver hand the completed ticket to the Driver of the leading locomotive Driver's advice to the Guard The Driver must advise the Guard (where provided) that Single Line Working is in operation when the train requires to travel over the single line in the wrong direction. The Guard must take into consideration:- station working, release of doors and safety of passengers protection arrangements if it is necessary to carry out the requirements of Section M (Part i) X.2.7 X.2.8 X.2.9 Warning everyone on or near the line If the Pilotman is not travelling with the first train over the single line, the Driver must be instructed to stop and tell everyone who is working on or near the line:- that Single Line Working has been introduced the line over which Single Line Working applies Passing a signal at Danger The Pilotman must ask the Signaller for permission before authorising the Driver to pass any signal at Danger. Pilotman to travel with the Driver The Pilotman must:- Page N.22 Master Rule Book 12/2002

23 ride with Uncontrolled the Driver in When the leading Printed cab unless following on a subsequent train. If, however, no Handsignaller has been provided to control wrong direction movements back to the proper line, the Pilotman must accompany every train over the single line in the wrong direction in order to remind the Driver of the location of the crossover being used by trains to return to the proper line if there is more than one locomotive, the Pilotman must ride with the Driver of the leading locomotive X.2.10 X.2.11 X X X Pilotman arriving at the end of the single line The Pilotman must, on arriving at the end of the single line:- collect the cancelled Driver's Single Line Working ticket from the Driver tell the Signaller immediately that he/she has arrived Intermediate signal boxes Before allowing an intermediate signal box to open, the Pilotman must dictate a Single Line Working form to the Signaller. The Signaller at an intermediate signal box must not permit a train to enter or foul the single line unless the Pilotman is present. The Pilotman can give permission for a train to work at an intermediate signal box without having to accompany the train. X.2.12 Checking points which have been secured The Pilotman must, from time to time, check to see that points which have been secured for Single Line Working:- remain secured, and the green flag or green light remains properly displayed at unworked points 12/2002 Master Rule Book Page N.23

24 X.2.13 X X X Withdrawn Document If the Pilotman Uncontrolled is relieved When Printed The Pilotman must, if relieved,:- make sure the relief fully understands the Single Line Working arrangements give the relief:- the Pilotman's Single Line Working form the Pilotman's armlet any padlock keys tell each Signaller and give the name of the relief to the Signaller not ride in the driving cab of any train over the single line The Signaller must record the name of the new Pilotman and the time on the Signaller's Single Line Working form. The new Pilotman must sign the Pilotman's Single Line Working form. X.2.14 X X If the Signaller is relieved The Signaller must make sure the relief:- fully understands the Single Line Working arrangements signs the Signaller's Single Line Working form in his/her presence If a Signaller comes on duty when Single Line Working is already in operation, that Signaller must tell the Pilotman as soon as possible. X.2.15 Speed restrictions The Signaller must tell the Pilotman about any temporary and emergency speed restrictions that are introduced during Single Line Working which will apply on the single line or affect any train returning to the proper line. Page N.24 Master Rule Book 12/2002

25 X.3 OBSERVANCE Uncontrolled OF SIGNALS When Printed X.3.1 X X Trains working over the single line in the right direction The Driver must obey each signal when travelling over the single line in the right direction. The Driver must not pass a signal at Danger unless authorised by the:- Signaller, or Pilotman, or Handsignaller, or Crossing Keeper X.3.2 X X X Trains working over the single line in the wrong direction The Driver must understand that all movements over the single line in the wrong direction will be controlled by handsignals in accordance with the Pilotman's instructions. The locations where handsignals must be displayed and the proceed aspect to be given are shown in clause If the Driver is advised by the Pilotman that a Handsignaller has not been provided to control wrong direction movements back to the proper line, the Driver must:- (i) stop the train (except as shown in (ii) below) at the following location:- opposite the signal which applies to the obstructed line protecting the crossover over which trains are returning to the proper line, or on an Absolute Block line, opposite the home signal that is worked from the same signal box that controls this crossover Master Rule Book Page N.25

26 (ii) (iii) Withdrawn Document if the crossover Uncontrolled over which When trains Printed are returning to the proper line is facing to movements, ask the Signaller for permission for the train to proceed over the crossover leading to the proper line or, if a signal is provided for the movement, proceed when the signal is cleared if the crossover over which trains are returning to the proper line is trailing to movements, ask the Signaller for instructions with regard to drawing forward and then setting back over the crossover leading to the proper line X.4 MOVEMENTS OVER THE SINGLE LINE X.4.1 X.4.2 First train over the single line The Driver of the first train to travel over the single line, must:- proceed cautiously stop where necessary to allow the Pilotman to tell anyone working on or near the line that Single Line Working has been introduced. The Driver must do this, if instructed to do so by the Pilotman stop where necessary to allow the Pilotman to tell any Crossing Keeper of the Single Line Working arrangements All movements over the single line The Driver must stop at each location where train movements are being controlled by handsignals unless a handsignal is displayed authorising the train to proceed. X.4.3 Movements over the single line in the right direction - Passing a signal at Danger The Driver must carry out the instructions contained in Section D when passing a signal at Danger. X.4.4 Movements over the single line in the wrong direction The Driver must make sure that:- Page N.26 Master Rule Book

27 the speed Uncontrolled of the train When does Printed NOT exceed 50 mph the appropriate instructions contained in Section D for wrong direction movements are carried out X.4.5 Disposal of the Driver's Single Line Working ticket (a) (b) When accompanied by the Pilotman On reaching the end of the single line, the Driver must:- cancel the ticket by writing the word "CANCELLED" across it give the ticket to the Pilotman When not accompanied by the Pilotman Unless specially instructed to do so, the Driver does not need to stop at the end of the single line to surrender the ticket. The Driver must, however, at the first convenient opportunity:- cancel the ticket by writing the word "CANCELLED" across it hand the ticket to his/her Supervisor when booking off duty X.5 FAILURE OF A TRAIN ON THE SINGLE LINE X.5.1 When the Pilotman is on the train The Pilotman must:- make arrangements with the Signaller for assistance to be provided for the failed train ask the Signaller for permission before making the movement if the failed train is to return to the same end of the single line as it entered Master Rule Book Page N.27

28 X.5.2 X X Withdrawn Document When the Pilotman Uncontrolled is not on When the train Printed The Signaller must ask the Pilotman for permission before authorising an assisting train to proceed onto the single line. The Pilotman must travel with the assisting train if:- the assistance is to come from the rear, and the failed train is to be withdrawn to the rear X.6 WITHDRAWAL OF SINGLE LINE WORKING X.6.1 X X Action the Pilotman must take The Pilotman must tell each Signaller concerned immediately when Single Line Working is to be withdrawn. The Pilotman must:- when the last train is clear, arrange for:- any Handsignallers to be withdrawn any points which have been secured to be released any green flag or light to be removed tell the person in charge at any station where the platform working was affected:- that Single Line Working is withdrawn whether the obstructed line is now open or is to remain blocked tell any Crossing Keeper affected:- that Single Line Working is withdrawn whether the obstructed line is now open or is to remain blocked If the Pilotman cannot verbally tell the Crossing Keeper, Page N.28 Master Rule Book

29 the Driver Uncontrolled of the first When train Printed to travel through the section must be instructed to stop at the Crossing and advise the Crossing Keeper arrange for the Driver of the first train to stop and tell anyone working on or near the line:- that Single Line Working is withdrawn whether the obstructed line is now open or is to remain blocked remove any hand danger signal provided in accordance with clause X.1.3(a) X If work on the obstructed line is to continue under either:- protection provided in accordance with Section T (Part ii), or possession in accordance with Section T (Part iii) the Pilotman must tell the PC, COSS or the PICOP, as appropriate, that Single Line Working is withdrawn. X.6.2 X Resumption of normal working When the Single Line Working arrangements have been withdrawn, the Pilotman must:- tell each Signaller concerned to cancel the Signaller's Single Line Working form obtain an assurance from each Signaller that this has been done The Pilotman must then cancel the Pilotman's Single Line Working form. X When the Signaller's Single Line Working form has been cancelled, each Signaller must make an entry in the Train Register as follows and sign it:- Master Rule Book Page N.29

30 "Single Line Uncontrolled Working When the...line Printed between... and...cancelled at...(time)" Normal working can then be resumed. X Cancelled Single Line Working forms and tickets must be forwarded to the local Manager. X.7 SINGLE LINE WORKING ON TRACK CIRCUIT BLOCK LINES WHERE THERE ARE MORE THAN TWO RUNNING LINES AND ALL LINES IN ONE DIRECTION ARE BLOCKED X.7.1 X X Method Where:- there are more than two running lines, and ALL lines in one direction are blocked, but two or more lines in the opposite direction remain open, Single Line Working must be introduced over one of the unobstructed lines Trains must be worked as follows:- trains prevented from running normally in one direction because of the lines being blocked must travel over the single line under Single Line Working conditions in accordance with this Section N trains running in the normal direction must travel over the unobstructed line(s) which is not being used for Single Line Working This method of working is demonstrated in Diagram 3N on page N.32. Page N.30 Master Rule Book

31 Note:- The Uncontrolled text in clauses When X.7.2 Printed to X.7.4 refers to Diagram 3N on page N.32. X.7.2 X.7.3 X X X Authority for wrong direction movements Trains arriving at Location "A" on the Up Fast or Up Slow line must:- set back to the Down Fast line over crossovers Nos 801 and 802 when the Pilotman gives authority, proceed over the Down Fast line under Single Line Working conditions as far as crossover No 805 from where they must return to the Up Fast line Where conflicting movements can be avoided The Signaller must if possible, avoid the situation occurring whereby trains travelling in the right direction conflict with trains being worked in the wrong direction. To avoid conflicting movements, the Signaller must:- divert trains travelling in the right direction to the line(s) which is to be used for such trains before reaching the Single Line Working allow these trains to continue along that line(s) beyond the Single Line Working In the example shown in Diagram 3N on page N.32, a conflict will occur if trains arriving at Location B on the Down Fast line cross to the Down Slow line via crossover No 806 and return to the Down Fast via crossover No 803. The conflict with up trains travelling over the Down Fast under Single Line Working occurs between:- "Z" and "Y" "V" and "W" Master Rule Book Page N.31

32 Uncontrolled When Printed DIAGRAM 3N X To avoid these conflicting movements, the Signaller must:- divert trains from the Down Fast line to the Down Slow line before they reach Location "B" allow trains to continue beyond Location "A" before they cross back to the Down Fast line X.7.4 Where conflicting movements cannot be avoided If the situation occurs whereby conflicting movements cannot be avoided, the following arrangements must apply. This is best explained by referring to the example in Diagram 3N:- (a) the Pilotman must appoint a Handsignaller at Location "B". The Pilotman must tell the Handsignaller to carry Page N.32 Master Rule Book

33 out Uncontrolled the instructions When contained Printedin Section F (Part ii), clause Up trains (b) when the Pilotman authorises up trains to pass over the Down Fast line, the Pilotman must instruct each Driver to proceed only as far as "Y". This instruction must be written on the Driver's Single Line Working ticket (c) all movements of up trains on the Down Fast line between "Y" and "Z" must be authorised by the Handsignaller at Location "B". The Handsignaller must, before authorising the movement, ask the Signaller for:- the necessary instructions permission for the train to proceed Down trains (d) trains arriving on the Down Fast line at Location "B" must only pass over the single line between "Z" and "Y" when authorised by the Handsignaller at Location "B". Before authorising the movement, the Handsignaller must ask the Signaller for:- (e) (f) the necessary instructions permission for the train to proceed the Signaller must before crossing trains back from the Down Slow line to the Down Fast line over crossover No. 803, ask the Pilotman for permission. The Pilotman must remain at Location "A" and authorise all movements between "V" and W" on the Down Fast line there is no need for:- the Pilotman to be present to authorise movements of trains between "Z" and "Y" a Single Line Working ticket to be given to the Drivers of down trains Master Rule Book Page N.33

34 X.7.5 X.7.6 X X Withdrawn Document Single Line Working Uncontrolled forms/tickets When Printed The Single Line Working forms and tickets must be amended as necessary to take account of this method of working. Protection arrangements The Driver and Guard must take into consideration the altered direction of train working that will occur during these Single Line Working arrangements if protection is required to be carried out in accordance with the instructions contained in Section M (Parts (i) or (ii)). If the Single Line Working arrangements have not been published in the Weekly Operating Notice, the Signaller must tell the Driver of EACH train travelling in the normal direction that trains on the adjoining line will be running in the opposite direction. X.7.7 Special working arrangements If the Handsignaller is not positioned at a signal, the Driver must be told by the Pilotman where the Handsignaller is positioned so that the Driver can be prepared to stop the train there. X.8 WORKING OF TRAINS TO AND FROM THE POINT OF OBSTRUCTION X.8.1 X.8.2 X Trains to run over one line only Single Line Working must be introduced over one line only when trains are required to work to and from a point of obstruction as a result of both lines of a double line becoming blocked. Method of Working The instructions contained in this Section N must be carried out in full except for the following modifications:- Page N.34 Master Rule Book

35 (a) Withdrawn Document the Uncontrolled Pilotman must When make Printed sure that one of the following is provided at the point where trains approaching the obstruction are required to stop:- emergency protection is provided in accordance with Section B (Part iii) or M (Part i), or a possession limit board has been provided in accordance with Section T (Part iii), or a signal is maintained at Danger X (b) If the emergency protection or possession limit board has already been provided, the Pilotman must, if necessary, arrange for that protection to be re-positioned so that trains can run as far as the place where they are required to stop the Pilotman must:- accompany all trains over the single line issue a Single Line Working ticket to the Driver of each train The Single Line Working forms and tickets must be amended as necessary to take account of this method of working. Master Rule Book Page N.35

36 Withdrawn Document RT3191/1 (Front) Uncontrolled When Printed PILOTMAN'S SINGLE LINE WORKING FORM (Form referred to in Rule Book, Section N) Name of Pilotman: Limits of Single Line Working: Date: All trains between the facing/trailing* crossover No. at and the facing/trailing* crossover No. at must pass over the line. This information has been dictated to the following Signaller(s):- Signal Box Name of Signaller Time Form Dictated Control of wrong direction movements back to proper line: On setting up Single Line Working, a Handsignaller has/has not* been provided at to control wrong direction movements back to the proper line. If a Handsignaller is appointed whilst Single Line Working is in operation, this was done at Change of Pilotman: Details on this form noted by: (name) (time/date) (name) (time/date) (name) (time/date) Change of Signaller: Signal Box Name of Signaller Time/date (time) EXAMPLE Cancellation of Single Line Working: Signal Box Name of Signaller Time/date Signed (Name of Pilotman) * delete as required Page N.36 Master Rule Book

37 Withdrawn Document Uncontrolled When Printed Single Line Working arrangements: Other Handsignaller(s) appointed at: RT3191/1 (Back) AHB level crossing locally operated at: Other manned level crossing at: RC/CCTV level crossing at: (With Attendant) (No Attendant) If an Attendant is appointed whilst Single Line Working is in operation, this was done at Miniature Red/Green Warning Light Crossing (without wrong direction controls) at: Barrow/foot crossings with White Light indications at: Unworked points at: Intermediate Signal Boxes: (Closed at) (Open at) Temporary/emergency speed restriction(s) over the single line of:- mph between and mph between and (time) EXAMPLE Temporary/emergency speed restriction on returning to the proper line of:- mph between and Other instructions: This form must be disposed of in accordance with the instructions in Rule Book Section N Master Rule Book Page N.37

38 Withdrawn Document Uncontrolled When PrintedRT3192/1 (Front) SIGNALLER'S SINGLE LINE WORKING FORM (Form referred to in Rule Book, Section N) Signal Box: Name of Pilotman: Limits of Single Line Working: Date: All trains between the facing/trailing* crossover No. at and the facing/trailing* crossover No. at must pass over the line. Signed (Signaller) (Time) Control of wrong direction movements back to proper line: On setting up Single Line Working, a Handsignaller has/has not* been provided at to control wrong direction movements back to the proper line. If a Handsignaller is appointed whilst Single Line Working is in operation, this was done at Change of Signaller: Details on this form noted by: (name) (time/date) (name) (time/date) (name) (time/date) Change of Pilotman: Name of new Noted by Time/date Pilotman Signaller (Name) (time) EXAMPLE Cancellation of Single Line Working: Single Line Working cancelled at (Time/date) Signed (Name of Signaller) * delete as required Page N.38 Master Rule Book

39 Withdrawn Document Uncontrolled When Printed Single Line Working arrangements: Other Handsignaller(s) appointed at: RT3192/1 (Back) AHB level crossing locally operated at: Other manned level crossing at: RC/CCTV level crossing at: (With Attendant) (No Attendant) If an Attendant is appointed whilst Single Line Working is in operation, this was done at Miniature Red/Green Warning Light Crossing (without wrong direction controls) at: Barrow/foot crossings with White Light indications at: Unworked points at: Intermediate Signal Boxes: (Closed at) (Open at) Temporary/emergency speed restriction(s) over the single line of:- mph between and mph between and (time) EXAMPLE Temporary/emergency speed restriction on returning to the proper line of:- mph between and Other instructions: This form must be disposed of in accordance with the instructions in Rule Book Section N Master Rule Book Page N.39

40 Single Line Working applies over the between the crossover which is facing/trailing* to your train at your train at Handsignaller(s) appointed at: AHB level crossing locally operated at: Other Instructions: (* delete as required) Withdrawn Document Uncontrolled When Printed RT3193/1 (Front) DRIVER'S SINGLE LINE WORKING TICKET MOVEMENT IN THE RIGHT DIRECTION (Form referred to in Rule Book, Section N) line and the crossover which is facing/trailing* to SIGNED (Name of Pilotman) EXAMPLE REMINDER TO DRIVER - Remember, if it is necessary to pass a signal at Danger, you must approach cautiously any points which are facing to your train and do NOT exceed 15 mph when passing over them. The instructions in Rule Book, Section D apply This ticket must be disposed of in accordance with the Rule Book, Section N Page N.40 Master Rule Book

41 Withdrawn Document RT3193/1 (Back) DRIVER'S Uncontrolled SINGLE When LINE WORKING Printed TICKET IN THE WRONG DIRECTION (Form referred to in Rule Book, Section N) Single Line Working applies over the line between the crossover which is facing/trailing* to your train at and the crossover which is facing/trailing* to your train at A Handsignaller has/has not* been provided at to control wrong direction movements back to the proper line. *delete as required Other Handsignaller(s) appointed at: AHB level crossing locally operated at: Other manned level crossing at: RC/CCTV level crossing at: (With Attendant) (No Attendant) Miniature Red/Green Warning Light Crossing (without wrong direction controls) at: Barrow/foot crossings with White Light indications at: Unworked points at: Intermediate Signal Boxes: (Closed at) (Open at) Temporary/emergency speed restriction(s) over the single line of:- mph between and mph between and Temporary/emergency speed restriction on returning to the proper line of:- mph between and Other instructions: EXAMPLE SIGNED (Name of Pilotman) REMINDER TO DRIVER - Remember, when travelling over the Single Line in the wrong direction, proceed at reduced speed and do NOT exceed 50 mph. Approach cautiously any points which are facing to your train and do NOT exceed 15 mph when passing over them. The instructions in Rule Book, Section D apply. This ticket must be disposed of in accordance with the Rule Book, Section N Master Rule Book Page N.41

42 Uncontrolled When Printed This page is intentionally left blank Page N.42 Master Rule Book

Withdrawn Document. SECTION F (Part ii) YOUR DUTIES IF YOU ARE ACTING AS A HANDSIGNALLER

Withdrawn Document. SECTION F (Part ii) YOUR DUTIES IF YOU ARE ACTING AS A HANDSIGNALLER Uncontrolled When Printed SECTION F (Part ii) YOUR DUTIES IF YOU ARE ACTING AS A HANDSIGNALLER Updated to October 1998 (Formatted for CD use) Rule Book No. 13 Page F(ii).1 Uncontrolled When Printed This

More information

Fixed Signals - Rules 1 to 23

Fixed Signals - Rules 1 to 23 Applicability VIC Publication Requirement External Only Document Status Issue/Revision # Effective from 1 07 August 2011 0 04 October 2015 1 01 July 2018 Australian Rail Track Corporation Limited (ARTC)

More information

Handbook 8. Handbook 8. IWA, COSS or PC blocking a line. GE/RT8000/HB8 Rule Book

Handbook 8. Handbook 8. IWA, COSS or PC blocking a line. GE/RT8000/HB8 Rule Book GE/RT8000/HB8 Rule Book Handbook 8 IWA, COSS or PC blocking a line Handbook 8 Issue 1 Valid from December 2010 Published by: RSSB Block 2 Angel Square 1 Torrens Street London EC1V 1NY. Contents approved

More information

Network Safeworking Rules and Procedures

Network Safeworking Rules and Procedures Network Safeworking Rules and Procedures Fixed Signals Rule Number: 6005 Version 1.0, 31 March 2016 Fixed Signals Rule Number: 6005 Document Control Identification Document title Number Version Date 6005

More information

Handbook 8. Issue 6. IWA, COSS or PC blocking a line. GERT8000-HB8 Rule Book. September 2017 Comes into force 02 December 2017

Handbook 8. Issue 6. IWA, COSS or PC blocking a line. GERT8000-HB8 Rule Book. September 2017 Comes into force 02 December 2017 GERT8000-HB8 Rule Book IWA, COSS or PC blocking a line Issue 6 September 2017 Comes into force 02 December 2017 Handbook 8 Uncontrolled when printed Published by: RSSB The authoritative version of this

More information

Track Work Authority ANWT 306. Applicability. Publication Requirement. Document Status NSW SMS. External Only October 2015.

Track Work Authority ANWT 306. Applicability. Publication Requirement. Document Status NSW SMS. External Only October 2015. Applicability NSW SMS Publication Requirement External Only Document Status Issue/Revision # Effective from 2.0 11 October 2015 Australian Rail Track Corporation Limited (ARTC) Disclaimer This document

More information

Where was the location of the incident?

Where was the location of the incident? Note: All mention of SPAD in this form refers to provisional SPAD. PART 1 INCIDENT DETAIL 1.1 1.2 What was the date of the incident? (dd/mm/yy) What was the time of the incident? (24 hour clock) 1.3 Where

More information

BURNLEY GROUP OPERATING PROCEDURES

BURNLEY GROUP OPERATING PROCEDURES The Operating Procedures contained in this document titled Burnley Group Operating Procedures refer to the area bounded by Richmond, Glen Waverley, Alamein, Belgrave & Lilydale. Approval Amendment Record

More information

Uncontrolled When Printed Document comes into force on 05/12/2015 Supersedes GERT8000-HB2 Iss 1 on 05/12/2015

Uncontrolled When Printed Document comes into force on 05/12/2015 Supersedes GERT8000-HB2 Iss 1 on 05/12/2015 GE/RT8000/HB2 Rule Book Uncontrolled When Printed Handbook 2 Instructions for track workers who use emergency protection equipment Handbook 2 Issue 2 September 2015 Comes into force 05 December 2015 This

More information

Responding to Signals and Signs

Responding to Signals and Signs Applicability NSW SMS Publication Requirement External Only Document Status Issue/Revision # Effective from 4.0 11 October 2015 Australian Rail Track Corporation Limited (ARTC) Disclaimer This document

More information

Lineside Signal Aspect Sequences

Lineside Signal Aspect Sequences ailway roup Standard K/T0032 Lineside Signal Aspect Sequences Synopsis This standard defines the sequence in which lineside signal aspects shall be presented to train drivers. This document is the property

More information

Ground Frames and Shunters Releases

Ground Frames and Shunters Releases Ground Frames and Shunters Synopsis This document mandates the interface requirements for ground frames and shunters releases that may be operated by railway undertaking personnel. Copyright in the s is

More information

Block System Interface Requirements

Block System Interface Requirements Block System Interface Requirements Synopsis This document mandates the requirements for block systems interfaces between signalling infrastructure and railway operations. Copyright in the s is owned by

More information

Lineside Signals, Indicators and Layout of Signals

Lineside Signals, Indicators and Layout of Signals To be part superseded by GKRT0045 Iss 4, GKRT0057 Iss 1 and GKRT0058 Iss 1 published on 06/12/2014 Lineside Signals, Indicators and Layout of Signals Synopsis This document defines the format, presentation

More information

Lineside Signal Aspect and Indication Requirements

Lineside Signal Aspect and Indication Requirements Lineside Signal Aspect and Indication Requirements Synopsis This document mandates the appearance of lineside signalling system displays and the information they convey. This document contains one or more

More information

SIGNALING PRACTICES ON PROTOTYPE AND MODEL RAILROADS

SIGNALING PRACTICES ON PROTOTYPE AND MODEL RAILROADS SIGNALING PRACTICES ON PROTOTYPE AND MODEL RAILROADS Bill Ataras September 30, 2013 PROTOTYPE SIGNALING PRACTICE 1. Many different types of signals A. Block signals B. Interlocking signals C. Whistles

More information

The Joys of Life Model Railway Club OPERATING THE RAILWAY. Not To Be Taken Away

The Joys of Life Model Railway Club OPERATING THE RAILWAY. Not To Be Taken Away The Joys of Life Model Railway Club OPERATING THE RAILWAY Not To Be Taken Away Operating the Joys of Life Railway Will High 1. Introduction The Joys of Life Railway is a 600 yard long, 5in gauge ground

More information

Lineside Signals, Indicators and Layout of Signals

Lineside Signals, Indicators and Layout of Signals Lineside Signals, Indicators and Layout of Signals Synopsis This document defines the format, presentation and layout of lineside signalling equipment that is used to display movement authority information

More information

British Signalling What the driver sees

British Signalling What the driver sees Railway Technical Website Background Paper No. 1 One of a series of papers originally published as pages on RTWP and updated for RTW. Introduction British Signalling What the driver sees by Piers Connor

More information

2 Layout and Use of Signals

2 Layout and Use of Signals Issued May 2 Layout and Use of Signals 2. General Signals are provided to control the movement of trains and to inform the driver whether it is safe to proceed. Their location is dictated largely by the

More information

Running Signals ANSG 600. Applicability. Publication Requirement. Document Status NSW SMS. External Only October 2015.

Running Signals ANSG 600. Applicability. Publication Requirement. Document Status NSW SMS. External Only October 2015. Applicability NSW SMS Publication Requirement External Only Document Status Issue/Revision # Effective from 3.0 11 October 2015 Australian Rail Track Corporation Limited (ARTC) Disclaimer This document

More information

Transportation Engineering -II Dr. Rajat Rastogi Department of Civil Engineering Indian Institute of Technology - Roorkee

Transportation Engineering -II Dr. Rajat Rastogi Department of Civil Engineering Indian Institute of Technology - Roorkee Transportation Engineering -II Dr. Rajat Rastogi Department of Civil Engineering Indian Institute of Technology - Roorkee Lecture - 22 Signals part - 1 Dear students, I welcome you back to the lecture

More information

Guidance on Lineside Signals, Indicators and Layout of Signals. Rail Industry Guidance Note for GK/RT0045

Guidance on Lineside Signals, Indicators and Layout of Signals. Rail Industry Guidance Note for GK/RT0045 GN Published by Block 2 Angel Square 1 Torrens Street London EC1V 1NY Copyright 2012 Rail Safety and Standards Board Limited GK/GN0645 Issue Two: March 2012 Rail Industry Guidance Note for GK/RT0045 Issue

More information

Signal Sighting. Withdrawn Document Uncontrolled When Printed. Railway Group Standard. Issue Two Date February 1996

Signal Sighting. Withdrawn Document Uncontrolled When Printed. Railway Group Standard. Issue Two Date February 1996 Railway Group Standard Signatures removed from electronic version Submitted by: Philip Wiltshire, Nominated Responsible Manager Approved by: Robin Nelson, Chairman, Train Control and Communications Subject

More information

Lineside Signal Aspects and Indications

Lineside Signal Aspects and Indications Supersedes Iss 1 (to correct formatting) and supersedes Lineside Signal Aspects and Indications Synopsis This document specifies the appearance of lineside signal aspects and s and the information they

More information

Signalling Cable Equivalent Sizes

Signalling Cable Equivalent Sizes Signalling Cable Equivalent Sizes Signatures removed from electronic version Submitted by... Jim Harper Nominated Responsible Manager Synopsis This Standard Authorises the use of cables to GS/ES 0872 as

More information

GK/GN0658. Guidance on Lineside Signal Aspect and Indication Requirements. Rail Industry Guidance Note for GK/RT0058

GK/GN0658. Guidance on Lineside Signal Aspect and Indication Requirements. Rail Industry Guidance Note for GK/RT0058 GN This document contains one or more pages which contain colour Published by: Block 2 Angel Square 1 Torrens Street London EC1V 1NY Copyright 2014 Rail Safety and Standards Board Limited GK/GN0658 Issue

More information

Engineering Instruction

Engineering Instruction Engineering Instruction Electrical Distribution Unit Approved by: Paul Poynton, A/Professional Head Electrical Engineering, Sydney Trains Authorised by: Jonathon McKinnon, Engineering Technical Publications

More information

Be sure to check the camera is properly functioning, is properly positioned and securely mounted, every time you operate your vehicle.

Be sure to check the camera is properly functioning, is properly positioned and securely mounted, every time you operate your vehicle. Please read all of the installation instructions carefully before installing the product. Improper installation will void manufacturer s warranty. The installation instructions do not apply to all types

More information

Sunbury SUNBURY (23 3/4 MILES)

Sunbury SUNBURY (23 3/4 MILES) Sunbury SUNBURY (23 3/4 MILES) Sunbury was the terminus of the first country section of the Victorian Railways to be opened in 1859 and the line was extended to the north two years later. The curious three

More information

INTRODUCTION OF COLOUR LIGHT SIGNALS AND NEW SIGNAL BOX AT MAIDSTONE EAST. On SUNDAY, 8th APRIL, 1962

INTRODUCTION OF COLOUR LIGHT SIGNALS AND NEW SIGNAL BOX AT MAIDSTONE EAST. On SUNDAY, 8th APRIL, 1962 Signal Instruction No. 21 S.E.D. SOUTHERN REGION-SOUTH EASTERN DIVISION Instructions to all concerned as to INTRODUCTION OF COLOUR LIGHT SIGNALS AND NEW SIGNAL BOX AT MAIDSTONE EAST (in place of certain

More information

Guidance on Signal Positioning and Visibility

Guidance on Signal Positioning and Visibility Guidance on Signal Positioning and Visibility Synopsis This document provides guidance on the requirements for positioning signals and indicators to ensure adequate viewing and clarity of meaning for drivers.

More information

Signalling Cable Equivalent Sizes (formerly RT/E/C/11213)

Signalling Cable Equivalent Sizes (formerly RT/E/C/11213) NR/GN/SIG/11213 Ref Date (formerly RT/E/C/11213) This temporary front sheet facilitates change to the new Network Rail Standards referencing nomenclature. The Ref above will be formally allocated to this

More information

Dear Railway Modeller,

Dear Railway Modeller, 1721_Betra_21_6915_0101.qxd 27.09.2007 12:15 Uhr Seite 25 6915 TURN-CONTROL Turntable Controller Contents Operating instructions GB Page 1. Safety Warnings and Advice on Use 26 1.2. Components, operational

More information

Briefing Note Publication

Briefing Note Publication Documents for Block System and for Ground Frames and Shunters Releases New documents Document Document title Issue GK/RT0055 Block System Interface Requirements 1 GK/GN0655 Guidance on Block System Interface

More information

RAILWAY INVESTIGATION REPORT R12D0063 UNPROTECTED OVERLAP OF AUTHORITY

RAILWAY INVESTIGATION REPORT R12D0063 UNPROTECTED OVERLAP OF AUTHORITY RAILWAY INVESTIGATION REPORT R12D0063 UNPROTECTED OVERLAP OF AUTHORITY AGENCE MÉTROPOLITAINE DE TRANSPORT TRAINS AMT 94 AND AMT 93 MILE 40.8, ADIRONDACK SUBDIVISION ADIRONDACK JUNCTION MONTRÉAL, QUEBEC

More information

Simplified Signaling for Modelers

Simplified Signaling for Modelers Simplified Signaling for Modelers Rule 281 Clear 1 Author: Gary Evans North Central Region, Division 3 garytrain47@frontier.com Revision: May 05, 2014 Handout: NORAC Signal Aspects Sheet 2 Introduction

More information

STANDARD FOR TELECOMMS WIRING AND TERMINATIONS

STANDARD FOR TELECOMMS WIRING AND TERMINATIONS GTlEH H802 Date MR 94 Paae I Part Synopsis This standard defines the Board's policy for the maintenance of Telecomms cable terminations. lthough the standard is centered on maintenance issues its provisions

More information

Cable Testing Basic guide to cable testing for newly qualified SMTH staff or trainees.

Cable Testing Basic guide to cable testing for newly qualified SMTH staff or trainees. Cable Testing Basic guide to cable testing for newly qualified SMTH staff or trainees. This is for information only. The SMTH MUST ALWAYS BE FOLLOWED AT ALL TIMES. F. M. Spowart June 2018 v1 Cable Testing

More information

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide GB05-7 Peak Atlas IT RJ45 Network Cable Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001/2013 In the interests of development, information

More information

The Netherlands. NS signals

The Netherlands. NS signals The Netherlands NS s 5.5. DUTCH RAILWAY SIGNALS The fotos of this chapter on Dutch ling are partly taken from www.nicospilt.com. 5.5.. Signalling SyStem 946 Netherlands rail started light experiments in

More information

Layout Design For Signaling

Layout Design For Signaling Layout Design For Signaling 2014, Rodney Black h t t p : / / h o m e.c o mca st.n e t / ~ kb 0o ys June 29, 2014 7/5/2014 1 Download 7/5/2014 Layout Design for Signaling 2 Outline 1. Why Signal a Layout

More information

SIGNALPERSON REFERENCE MANUAL

SIGNALPERSON REFERENCE MANUAL NATIONAL COMMISSION FOR THE CERTIFICATION OF CRANE OPERATORS (NCCCO) SIGNALPERSON REFERENCE MANUAL SGP RM 10/10 This page intentionally left blank Hold Harmless/Release/Disclaimer Agreement The reading

More information

ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION

ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION 1.0 General 1.1 The work covered by this section consists of providing all labor, equipment, insurance, accessories, tools, transportation, supplies,

More information

PRIVATE and not for Publication NOTICE No. S.2649 BRITISH RAILWAYS. (WESTERN REGION) (For the use of employees only) Notice to Trainmen, etc.

PRIVATE and not for Publication NOTICE No. S.2649 BRITISH RAILWAYS. (WESTERN REGION) (For the use of employees only) Notice to Trainmen, etc. PRIVATE and not for Publication NOTICE No. S.2649 BRITISH RAILWAYS (WESTERN REGION) (For the use of employees only) Notice to Trainmen, etc. MULTIPLE ASPECT SIGNALLING BRISTOL (Stage 3.C.-Bristol Temple

More information

ServicePlus S17R Series 2 User Operating Instructions

ServicePlus S17R Series 2 User Operating Instructions ServicePlus S17R Series 2 User Operating Instructions Single Channel Timeswitch The Horstmann ServicePlus S17R timeswitch will allow up to 3 ON/ settings per 24 hours on a weekly schedule and has a 1 hour

More information

Transportation Engineering - II Dr. Rajat Rastogi Department of Civil Engineering Indian Institute of Technology - Roorkee

Transportation Engineering - II Dr. Rajat Rastogi Department of Civil Engineering Indian Institute of Technology - Roorkee Transportation Engineering - II Dr. Rajat Rastogi Department of Civil Engineering Indian Institute of Technology - Roorkee Lecture 25 Interlocking of Track Dear students, welcome you back to the lecture

More information

Layout Design For Signaling

Layout Design For Signaling Layout Design For Signaling 2 0 1 5, Ro d n e y B l a c k N o v e m b e r 1 5, 2 0 1 5 11/15/2015 1 Download This Presentation 11/15/2015 Layout Design for Signaling 2 Outline 1. Why Signal a Layout 2.

More information

Kyneton KYNETON (40 MILES)

Kyneton KYNETON (40 MILES) Kyneton KYNETON (40 MILES) Kyneton was the terminus of the third section; the line was opened to Kyneton in April 1862 and extended to Castlemaine in October 1862. Kyneton had a small goods yard to serve

More information

(LONDON MIDLAND REGION) SPECIAL NOTICE 1855 G.

(LONDON MIDLAND REGION) SPECIAL NOTICE 1855 G. PRIVATE and not for Publication BRITISH RAILWAYS (LONDON MIDLAND REGION) SPECIAL NOTICE 1855 G. N01-ICE TO DRIVERS, GUARDS, SIGNALMEN AND OTHERS CONCERNED RESPEC1-ING THE INTRO DUC1-ION OF MULTIPLE ASPECT

More information

Final Report. Rail inquiry RO Signalling irregularity Wellington Railway Station 3 April 2017

Final Report. Rail inquiry RO Signalling irregularity Wellington Railway Station 3 April 2017 Final report RO-2017-102: Signalling irregularity, Wellington Railway Station, 3 April 2017 The Transport Accident Investigation Commission is an independent Crown entity established to determine the circumstances

More information

ORDER CODE: EQLED65 USER MANUAL

ORDER CODE: EQLED65 USER MANUAL www.prolight.co.uk ORDER CODE: EQLED65 USER MANUAL Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this equipment away from rain,

More information

W A T C H. Using Your Remote Control. 145 N. Main Lenora, KS toll free

W A T C H. Using Your Remote Control. 145 N. Main Lenora, KS toll free W A T C H Using Your Remote Control 145 N. Main Lenora, KS 67645 toll free 877-567-7872 ADB 3800 TV - Sends commands to TV DVD - Sends commands to DVD STB - Sends commands to set-top box Setup AV - Choose

More information

Signal Sighting Standard

Signal Sighting Standard Engineering Standard Signals L1-CHE-STD-004 Signal Sighting Standard Version: 1 Issued: June 2016 Owner: Engineering Approved By: Phil Ellingworth Chief Engineer PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO

More information

Hotel Ballroom. Figure 1 above, graphically details this scenario. 8:1 1 of 5. We ve got it under control

Hotel Ballroom. Figure 1 above, graphically details this scenario. 8:1 1 of 5. We ve got it under control In this application we have a Ballroom for a typical 5 Star Hotel. The Ballroom is complete with a Prefunction area and has two de-mountable partitions in the main area. These partitions may be closed

More information

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017 M150SP USER S AND INSTALLER S MANUAL v2.0 REV. 03/2017 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. THE DEVICE TECHNICAL SPECIFICATIONS VISUAL ASPECT CONNECTORS

More information

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer CP027 User Operating Instructions Two Channel Central Heating and Hot Water r The CP027 two channel programmer gives independent control over hot water and heating with up to 3 ON/ settings for each day

More information

A digital version of this document is available to download and submit online at ADDRESS POST CODE

A digital version of this document is available to download and submit online at   ADDRESS POST CODE CHECK LIST i A digital version of this document is available to download and submit online at www.thorlux.com/commissioning To secure your preferred commissioning date please complete this form and email

More information

TECHNICAL BULLETIN. Ref. No. P (Repl P-03-11)

TECHNICAL BULLETIN. Ref. No. P (Repl P-03-11) 0 TECHNICAL BULLETIN August 2006 Ref. No. P-06-01 (Repl P-03-11) Guidelines for Selection of Replacement Tires --Including Substitute Tire Sizes-- With Important Safety Information To ensure the same performance

More information

THE "HEAVENS OF COPERNICUS" PLANETARIUM VISITOR REGULATIONS

THE HEAVENS OF COPERNICUS PLANETARIUM VISITOR REGULATIONS THE "HEAVENS OF COPERNICUS" PLANETARIUM VISITOR REGULATIONS 1 The "Heavens of Copernicus" Planetarium 1. One of the attractions of the Copernicus Science Centre is the "Heavens of Copernicus" Planetarium

More information

THE MINACK THEATRE. Notes for Playing Companies. Please note 2016 amendment to Section 5 - Public Liability & Employer Liability Insurance

THE MINACK THEATRE. Notes for Playing Companies. Please note 2016 amendment to Section 5 - Public Liability & Employer Liability Insurance THE MINACK THEATRE Notes for Playing Companies 2018 Please note 2016 amendment to Section 5 - Public Liability & Employer Liability Insurance Please note 2017 amendment to Section 9 Child Performers Please

More information

Owners SW-LCD 2.0 Manual & Specifications

Owners SW-LCD 2.0 Manual & Specifications Owners SW-LCD 2.0 Manual & Specifications Contents 1. Preface. 19 2. Appearance and Size.20 2.1 Material and Color 20 2.2 Display Size and Installation Size 20 3. Function Summary and Button Definition

More information

CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch

CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch CP017 USER OPERATING INSTRUCTIONS Single Channel Timeswitch The CP017 timeswitch will allow up to 3 ON/ settings per day for each day of the week and has a 1 hour manual boost and advance button to temporarily

More information

NMRA 2013 Peachtree Express Control Panel Editor - B

NMRA 2013 Peachtree Express Control Panel Editor - B NMRA 2013 Peachtree Express Control Panel Editor - B Dick Bronson RR-CirKits, Inc. JMRI Control Panel Editor for Automatic Train Running Using Warrants Items Portal Table The 'Portal Table' is part of

More information

APPROVED for connection to Telecommunication systems specified in the instructions for use subject to the conditions set out in them.

APPROVED for connection to Telecommunication systems specified in the instructions for use subject to the conditions set out in them. TM COMSPHERE 3900 Series Modems Models 3910 and 3911 Government Requirements for Great Britain Document Number 3910-A2-GK42-10 November 1996 Overview This document highlights government requirements, safety

More information

Tokenless Block System Basic layout and operation

Tokenless Block System Basic layout and operation Tokenless Block System Basic layout and operation This document is not endorsed by Network Rail. It is NOT for installation, commissioning, testing or maintenance purposes, it is for information only.

More information

USER GUIDE 8-CHANNEL DMX CONTROLLER December 2013 Version 1.0 CHASE / STROBE SPEED FADE SPEED RED GREEN BLUE WHITE AMBER DIMMER INSERT

USER GUIDE 8-CHANNEL DMX CONTROLLER December 2013 Version 1.0 CHASE / STROBE SPEED FADE SPEED RED GREEN BLUE WHITE AMBER DIMMER INSERT 8-CHANNEL DMX CONTROLLER RED GREEN BLUE YELLOW 1 2 3 4 5 6 CYAN ORANGE PURPLE WHITE RED GREEN BLUE WHITE AMBER DIMMER RECORD INSERT DELETE TAP CLEAR MANUAL MUSIC 1 2 3 5 6 7 AUTO CHASE / STROBE SPEED 4

More information

67. LEVEL TRANSITION FROM LEVEL NTC TO LEVEL 1 (SYSTEM VERSION 2.Y)

67. LEVEL TRANSITION FROM LEVEL NTC TO LEVEL 1 (SYSTEM VERSION 2.Y) 123-133 Rue Froissart, 1040 Brussels, Belgium Tel: +32 (0)2 673.99.33 - TVA BE0455.935.830 Website: www.ertms.be E-mail: info@ertms.be ERTMS USERS GROUP - ENGINEERING GUIDELINE 67. LEVEL TRANSITION FROM

More information

Guest Editor Pack. Guest Editor Guidelines for Special Issues using the online submission system

Guest Editor Pack. Guest Editor Guidelines for Special Issues using the online submission system Guest Editor Pack Guest Editor Guidelines for Special Issues using the online submission system Online submission 1. Quality All papers must be submitted via the Inderscience online system. Guest Editors

More information

THE CITY OF WATERLOO SPECIFICATION FOR THE INVESTIGATION OF SANITARY SEWER LATERALS USING CLOSED CIRCUIT TELEVISION CAMERA (CCTV) 2016

THE CITY OF WATERLOO SPECIFICATION FOR THE INVESTIGATION OF SANITARY SEWER LATERALS USING CLOSED CIRCUIT TELEVISION CAMERA (CCTV) 2016 THE CITY OF WATERLOO SPECIFICATION FOR THE INVESTIGATION OF SANITARY SEWER LATERALS USING CLOSED CIRCUIT TELEVISION CAMERA (CCTV) 2016 TABLE OF CONTENT 1.0 SCOPE OF WORK... 3 1.1 GENERAL... 3 1.2 OBJECTIVES:...

More information

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual. Installation and Operation Instructions CD3766 Directional LED Available in various color combinations, the CD3766 Directional LED is a surface mount, dual color warning light that is ideal for a wide

More information

User Instructions. 16 SCB Sync Station.

User Instructions. 16 SCB Sync Station. User Instructions 16 SCB Sync Station Contents Overview... 1 Specifications... 1 Compliance and approvals... 2 Safety instructions... 3 Set up... 4 How to charge multiple devices... 4 How to synchronize

More information

DDW36C Advanced Wireless Gateway - Safety and Installation Product Insert. Federal Communications Commission (FCC) Interference Statement

DDW36C Advanced Wireless Gateway - Safety and Installation Product Insert. Federal Communications Commission (FCC) Interference Statement DDW36C Advanced Wireless Gateway - Safety and Installation Product Insert Federal Communications Commission (FCC) Interference Statement This equipment has been tested and found to comply with the limits

More information

signal book Scandinavia decoder die Alleskönner the all-in-one decoder Modellbahnelektronik aus Dresden model railway electronics from Dresden

signal book Scandinavia decoder die Alleskönner the all-in-one decoder Modellbahnelektronik aus Dresden model railway electronics from Dresden Trafo decoder die Alleskönner the all-in-one decoder A0 A A A3 A4 A5 A6 A7 03 Gleis Z-6 decoder Signal Prog A5 A4 A3 A A A0 A9 A8 book Scandinavia Modellbahnelektronik aus Dresden model railway electronics

More information

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional B-Tronic EasyControl EC5415B en Assembly and Operating Instructions Wall/hand-held transmitter, 15-channel, bidirectional Important information for: Fitters / Electricians / Users Please forward accordingly!

More information

Rental Guidelines and Policies for the Historic Paramount Theatre, Inc.

Rental Guidelines and Policies for the Historic Paramount Theatre, Inc. Rental Guidelines and Policies for the Historic Paramount Theatre, Inc. 352 Cypress Street www.paramount-abilene.org Phone: 325-676-9620 Abilene, Texas 79601 Fax: 325-676-0642 RENTAL AGREEMENT 1. Contracts

More information

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE

4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE 4-PROJECTOR BAR WITH 3 X 9W LEDS AND 1 X 1W FLASH LED USER GUIDE 10482 - Version 1 / 04-2016 English LIVESET - LIVESET - 4-Projector bar with 3 x 9W LEDs and 1 x 1W Flash LED 1 - Safety information Important

More information

CANADIAN RAILWAY OFFICE OF ARBITRATION & DISPUTE RESOLUTION CASE NO Heard in Montreal, January 11, Concerning CANADIAN PACIFIC RAILWAY

CANADIAN RAILWAY OFFICE OF ARBITRATION & DISPUTE RESOLUTION CASE NO Heard in Montreal, January 11, Concerning CANADIAN PACIFIC RAILWAY CANADIAN RAILWAY OFFICE OF ARBITRATION & DISPUTE RESOLUTION CASE NO. 4610 Heard in Montreal, January 11, 2018 Concerning CANADIAN PACIFIC RAILWAY And TEAMSTERS CANADA RAIL CONFERENCE DISPUTE: Appeal of

More information

Specification. NGTS Issue 1 October 1993

Specification. NGTS Issue 1 October 1993 The Electrical Standards for SHE Transmission s area are non-maintained versions of National Grid Technical Specifications that are applicable to the SHE Transmission System only. These specific versions

More information

Warning and Safety Information. FCC Information

Warning and Safety Information. FCC Information Installation Manual Warning and Safety Information FCC Information This device complies with FCC Rules Part 15 Operation and is subject to the following two conditions: (1) This device may not cause harmful

More information

FV400 DIGITAL TV RECEIVER WITH MODULATOR INSTRUCTION MANUAL

FV400 DIGITAL TV RECEIVER WITH MODULATOR INSTRUCTION MANUAL FV400 DIGITAL TV RECEIVER WITH MODULATOR INSTRUCTION MANUAL Please read this instruction manual carefully before using your receiver Table of Contents Introduction-----------------------------------------------------------------------------

More information

Technical Description Track-Control

Technical Description Track-Control Technical Description Track-Control Uhlenbrock Elektronik GmbH Mercatorstraße 6 46244 Bottrop E-Mail: info@uhlenbrock.de Web: www.uhlenbrock.de TV 1.0. 17.09.2007 Track-Control 1. Overall Operation 1.1

More information

Integrated Communications Platform ACD 2000 AGENT/SUPERVISOR GUIDE FOR THE MITEL NETWORKS 5020 IP PHONE

Integrated Communications Platform ACD 2000 AGENT/SUPERVISOR GUIDE FOR THE MITEL NETWORKS 5020 IP PHONE M I T E L N E T W O R K S 3300 Integrated Communications Platform ACD 2000 AGENT/SUPERVISOR GUIDE FOR THE MITEL NETWORKS 5020 IP PHONE DUE TO THE DYNAMIC NATURE OF THE PRODUCT DESIGN, THE INFORMATION CONTAINED

More information

Frequently Asked Questions

Frequently Asked Questions Frequently Asked Questions Elton John And His Band WIN Stadium Sunday 24 September 2017 I have purchased a ticket but I don t have it yet. How do I pick it up? You can pick up your event ticket from any

More information

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1 Instruction Manual 2.4G Digital Wireless Four Channel Transmitter System RVS-554W 1 NOTE! Please read all of the installation instructions carefully before installing the product. Improper installation

More information

Original BMW Accessory. Installation Instructions.

Original BMW Accessory. Installation Instructions. Original BMW Accessory. Installation Instructions. ipod Interface Retrofit BMW 5 Series (E 60, E 6) BMW 6 Series (E 63, E 64) These installation instructions are only valid for cars without SA 67 (CD changer)

More information

BBC Written Archives Centre. Information for Visiting Researchers

BBC Written Archives Centre. Information for Visiting Researchers BBC Written Archives Centre Information for Visiting Researchers BBC Written Archives Centre Information for Visiting Researchers Contents Service Provision... 2 Opening Hours... 2 Contact Details... 2

More information

DIGITAL SET TOP BOX STB 7017 INSTRUCTION MANUAL

DIGITAL SET TOP BOX STB 7017 INSTRUCTION MANUAL DIGITAL SET TOP BOX STB7017 INSTRUCTION MANUAL STB 7017 CHANNEL After Sales Support Now you have purchased a Tevion product you can rest assured in the knowledge that as well as your 3 year parts and labour

More information

Owner's Manual. Technical Audio for the 21 st Century Classroom

Owner's Manual. Technical Audio for the 21 st Century Classroom Owner's Manual Technical Audio for the 21 st Century Classroom OWNER'S MANUAL For use with the following Ensémble system. System No.: ENS-903 ENS-903-ORB Index 1 Contact Info CETACEA SOUND CORP 2003 East

More information

Interactive Satellite Terminal Installation / Validation Manual

Interactive Satellite Terminal Installation / Validation Manual Installation / Validation Manual Version October 5, 2016 Index INTERACTIVE SATELLITE TERMINAL 1. FCC COMPLIANCE... 3 2. TECHNICAL FEATURES...4 3. GENERAL DESCRIPTION...5 4. ELEMENTS CONTAINED IN THE TERMINAL...6

More information

Please follow the safety instructions in your notebook s directions for use.

Please follow the safety instructions in your notebook s directions for use. TV Remote Control Tuner Content Safety Instructions... 2 Battery disposal... 2 Summary... 3 TV card... 3 Remote control... 4 Inserting batteries... 4 Button Layout... 5 Changing the transmission/reception

More information

TWIC IMPLEMENTATION ACCESS AND ESCORTING

TWIC IMPLEMENTATION ACCESS AND ESCORTING AAPA Port Operations, Safety and Information Technology Seminar TWIC IMPLEMENTATION ACCESS AND ESCORTING June 10,2009 STATUS OF ENROLLMENTS Mobile has the sixth highest number of enrollments of the 146

More information

DEPARTMENTAL GENERAL ORDER DEPARTMENT OF PUBLIC SAFETY January 8, 2003 MERCER ISLAND POLICE

DEPARTMENTAL GENERAL ORDER DEPARTMENT OF PUBLIC SAFETY January 8, 2003 MERCER ISLAND POLICE DEPARTMENTAL GENERAL ORDER 91-2 R-9 (Revised) DEPARTMENT OF PUBLIC SAFETY January 8, 2003 MERCER ISLAND POLICE Index as: Audio and Video Recording Camera, Video Equipment Use Photography, Audio/Video Use

More information

3WS(Cape Town/Secretariat)1

3WS(Cape Town/Secretariat)1 For IEC use only 3WS(Cape Town/Secretariat)1 2005-10-04 INTERNATIONAL ELECTROTECHNICAL COMMISSION Technical Committee No. 3: Information structures, documentation and graphical symbols Occurrence-related

More information

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1 6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE 10364-07-2015 / Version 1 English MINITRUSS-6TCb - 6x3W RGB LEDs projector for professional trusses 2 MINITRUSS-6TCb - 6x3W RGB LEDs projector

More information

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Dragonfly Quad. User Manual V1.4. Order code: EQLED101 Dragonfly Quad User Manual V1.4 Order code: EQLED101 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

Be sure to run the vehicle engine while using this unit to avoid battery exhaustion.

Be sure to run the vehicle engine while using this unit to avoid battery exhaustion. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNE; Please Read all of these instructions regarding

More information

PREAMPLIFIER INTRODUCTION INSTRUCTIONS FOR USE. Thank you for purchasing the Musical Fidelity A3 CR remote control preamplifier.

PREAMPLIFIER INTRODUCTION INSTRUCTIONS FOR USE. Thank you for purchasing the Musical Fidelity A3 CR remote control preamplifier. INTRODUCTION A3 CR PREAMPLIFIER INSTRUCTIONS FOR USE Thank you for purchasing the Musical Fidelity A3 CR remote control preamplifier. Used properly and carefully, it should give you many years of outstanding

More information

CONTEST CHAIRMAN BRIEFING FOR THE EVALUATION SPEECH CONTEST

CONTEST CHAIRMAN BRIEFING FOR THE EVALUATION SPEECH CONTEST CONTEST CHAIRMAN BRIEFING FOR THE EVALUATION SPEECH CONTEST To be conducted by the Contest Chairman or Contest Toastmaster Club Contest conduct the briefing either prior to the meeting or during the meeting

More information

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1

More information