Selector guide. PSC Square body fuses Size 7X VAC End contact terminals. Features and Benefits
|
|
- Mariah Bruce
- 5 years ago
- Views:
Transcription
1 Selector guide PSC Square body fuses Size 7X C End contact terminals November 201 Issue 2 The IXYS UK range of 100/1250 protistor fuse links provides maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. These square body fuse links are available in different body sizes, each size having multiple worldwide acceptable mounting styles. These protistors have been designed to provide state of the art protection for all IXYS UK high power semiconductors; diodes, thyristors, GTO s and IGBT devices. These fuses are assembled with pure silver, die cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I 2 t and high interrupting rate level. ll contact surfaces are silver plated and all hardware is nonmagnetic Each fuse link is equipped with a low voltage trip indicator which can operate a field mountable microswitch. Features and Benefits Ultra fast acting Current limiting ery low I 2 t for improved semiconductor protection Superior cycling capability Multiple body sizes and terminal connections ar class according to DE 66 2 and IEC pplications Protection of inverters, UPS systems, motor drives and similar equipment rated at 100/1250 or less pprovals UL/CS recognised component C: UL guide no. E76491 IEC compliance RoHS compliant
2 Selector guide PSC Square body fuses Size 7X C end contact Terminals Nomenclature The IXYS UK range of 100/1250 protistor fuse links with blade terminals consists of five different body styles and the following nomenclature details the breakdown of each type UR 2 S 0400 B Rated voltage Type and Fixing R current Size 10 standard dimension rating Indicator type Type and Standard Information US DIN 4 65 US dimensions, large square body UR DIN 4 65, German/French dimensions, large square body Body Size Fixing Dimension S Stud/threaded hole, metric thread U Stud/threaded hole, imperial thread Indicator Type B Button type Example 125UR2S0400B is 100/1250C (R), DIN 4 65 German/French dimensions, large square body, size 72, metric thread, 400 nominal R current with button indicator
3 Selector guide PSC Square body fuses Size 7X C end contact Terminals Size 70 fuses Part numbers Weight 50g Max. US0U fuses US dimensions UR0S fuses UR dimensions Part Number 100/ ar 10US0U006B 100/ ar 10US0U0080B 100/ ar 10US0U0100B 100/ ar 10US0U0125B 100/ ar 10US0U0160B 100/ ar 10US0U0200B 100/ ar 10US0U0250B 100/ ar 10US0U0280B 100/ ar 10US0U015B 1200/ ar 120US0U050B Size 70 fuses Ratings Rated oltage (UL/IEC) Part Number 100/ ar 125UR0S0050B 100/ ar 125UR0S006B 100/ ar 125UR0S0080B 100/ ar 125UR0S0100B 100/ ar 125UR0S0125B 100/ ar 125UR0S0160B 100/ ar 125UR0S0200B 100/ ar 125UR0S0250B 100/ ar 120UR0S0280B 100/ ar 120UR0S015B 1200/ ar 110UR0S050B* 1200/ ar 110UR0S0400B* 1200/ ar 110UR0S0450B* 1100/ ar 100UR0S0500B* 900/ ar 080UR0S0550B* Nominal Current Pre arcing I 2 t Clearing I 2 Watts 100% In Breaking k 2 s k 2 s W k 100/ ar / ar / ar / ar / ar / ar / ar / ar / ar / ar / ar / ar / ar / ar / ar * Non UL recognised rating
4 Selector guide PSC Square body fuses Size 7X C end contact Terminals Size 71 fuses Part numbers Weight 500g Max. for US dimensions, 520g Max. for UR dimensions US1U fuses US dimensions UR1S fuses UR dimensions Size 71 fuses Ratings Rated oltage (UL/IEC) Part Number 100/ ar 10US1U0160B 100/ ar 10US1U0200B 100/ ar 10US1U0250B 100/ ar 10US1U0280B 100/ ar 10US1U015B 100/ ar 10US1U050B 100/ ar 10US1U0400B 100/ ar 10US1U0450B 1200/ ar 120US1U0500B 1200/ ar 120US1U0550B 1100/ ar 120US1U060B* Part Number 100/ ar 125UR1S0160B 100/ ar 125UR1S0200B 100/ ar 125UR1S0250B 100/ ar 125UR1S0280B 100/ ar 125UR1S015B 100/ ar 125UR1S050B Product 100/1250 Brief Title 400 ar 125UR1S0400B 100/ ar 125UR1S0450B 1200/ ar 110UR1S0500B 1200/ ar 110UR1S0550B 1100/ ar 100UR1S060B 1100/ ar 100UR1S0700B 950/ ar 090UR1S0800B 850/ ar 080UR1S0900B Nominal Current Pre arcing I 2 t Clearing I 2 Watts 100% In Breaking k 2 s k 2 s W k 100/ ar / ar / ar / ar / ar / ar / ar / ar / ar / ar / ar / ar Selector guide PSC Square body fuses Size 7X C Blade Terminals 950/ ar / ar * Non UL recognised rating
5 Selector guide PSC Square body fuses Size 7X C end contact Terminals Size 72 fuses Part numbers Weight 850g Max. for US dimensions, 800g Max. for UR dimensions US2U fuses US dimensions UR2S fuses UR dimensions Part Number 100/ ar 10US2U0280B 100/ ar 10US2U015B 100/ ar 10US2U050B 100/ ar 10US2U0400B 100/ ar 10US2U0450B 100/ ar 10US2U0500B 100/ ar 10US2U0550B 1200/ ar 120US2U060B* 1100/ ar 110US2U0700B* 1100/ ar 110US2U0800B* Part Number 100/ ar 125UR2S0250B 100/ ar 125UR2S0280B 100/ ar 125UR2S015B 100/ ar 125UR2S050B 100/ ar 125UR2S0400B 100/ ar 125UR2S0450B 100/ ar 125UR2S0500B 100/ ar 125UR2S0550B 1200/ ar 110UR2S060B* 1200/ ar 100UR2S0700B* 1200/ ar 100UR2S0800B* 1100/ ar 100UR2S0900B* 900/ ar 085UR2S1000B* Size 72 fuses Ratings Rated oltage (IEC/UL) Nominal Current Pre arcing I 2 t Clearing I 2 Watts 100% In Breaking k 2 s k 2 s W k 100/ ar 100/ ar / ar / ar / ar / ar / ar / ar / ar / ar / ar / ar Product Brief 900/850 Title 1000 ar * Non UL recognised rating
6 Selector guide PSC Square body fuses Size 7X C end contact Terminals Size 7 fuses Part numbers Weight 1250g Max. USU fuses US dimensions Part Number 100/ ar 10USU015B 100/ ar 10USU050B 100/ ar 10USU0400B 100/ ar 10USU0450B 100/ ar 10USU0500B 100/ ar 10USU0550B 100/ ar 10USU060B 100/ ar 10USU0700B 100/ ar 10USU0800B 100/ ar 10USU0900B 1100/ ar 110USU1000B 1000/ ar 100USU1100B 1000/ ar 100USU1250B 900/ ar 090USU1400B 700/ ar 070USU1600B 650/ ar 065USU1800B URS fuses UR dimensions Size 7 fuses Ratings Part Number 100/ ar 125URS015B 100/ ar 125URS050B 100/ ar 125URS0400B 100/ ar 125URS0450B 100/ ar 125URS0500B 100/ ar 125URS0550B 100/ ar 125URS060B 100/ ar 120URS0700B 100/ ar 125URS0800B 100/ ar 120URS0900B 1100/ ar 100URS1000B 1000/ ar 095URS1100B 1000/ ar 090URS1250B 900/ ar 085URS1400B 700/ ar 069URS1600B 650/ ar 060URS1800B Pre arcing I 2 Clearing I 2 Watts Breaking t 100% In k 2 s k 2 s W k 100/ ar / ar / ar / ar / ar / ar / ar / ar / ar / ar / ar / ar / ar / ar / ar / ar
7 Selector guide PSC Square body fuses Size 7XX C end contact Terminals Drawings and Dimensions USxU fuses Size US0U 40 US1U 51 US2U 60 USU 74.5 B C D d E 26 5/ / / / G P URxS fuses Size UR0S UR1S UR2S URS B C D d M8 M8 M10 M12 E G M N P ll dimensions in mm unless otherwise stated ysuk.com
8 Selector guide PSC Square body fuses Size 7X C end contact Terminalss Microswitches IXYS UK can offer a range of microswitches to suit our PSC square bodied fuse ranges System: Fuse sizes: Indication style: , 71, 72, = Standard NO NC BS = Low Level NO NC ET = Low Level NO NC IP 50 (9) BS = Low Level NO NC Partt number BS ET C Insulation oltage Rating *** () 1500 Positive Operating oltage/current (/m) 20/50 10/10 10/10 Current Rating () Current () 10 C 50/ /60Hz DCC 10 8 C 50/ /60Hz DCC 0 C 50/ /60Hz DCC Interrupting Rating () Non inductive circuit Inductive Circuit: L/R = 25ms C oltage Withstandd * (k) Impulse oltage test imp 1.2/50µs ** (k) Fire according to UL 94 H.B BS 10/10 C 50/ /60Hz DCC Fuse Holder Part Number Fuse size Fuse Type Insulation oltage () C, 50/60Hz & DC Rated Current () Dimensions B C D E G L M F SI TT 70/71 SI TT 72/ Stud M8 M10 M12 57 ll dimensions in mm IXYS UK Westcode Ltd s BS EN ISO9001 quality system is registered by BSI Langley Park Way Chippenham, SN15 1GE United Kingdom Tel: +44 (0) Fax: +44 (0) E mail: sales@ixysuk.net Edisonstr. 155 D 6862 Lampertheim Germany Tel: +49 (0) Fax: +44 (0) E mail: marcom@ixys.de ysuk.com We are supported by a global network of local offices, representatives and distributors. Please visit ourr website for more information
Magnetic and Hydraulic-Magnetic Circuit Breaker
Magnetic and Hydraulic-Magnetic Circuit Breaker 850-... Description Single, two, three and four pole magnetic and hydraulic-magnetic circuit breakers with trip-free-mechanism and toggle or rocker actuation.
More informationMagnecraft Power Relays
Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These
More informationMagnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A
and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature
More informationTeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40
Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,
More informationPBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories
PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.
More informationA V 50Hz / V 60Hz
A16-22-00 400-415V 50Hz / 415-440V 60Hz Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: A16-22-00 400-415V 50Hz / 415-440V
More informationType: DILM25 10(24V50HZ) Article No.:
Type: DILM25 10(24V50HZ) Article No.: 277119 Ordering information Rated operational current AC 3 400 V I e A 25 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationKuhnke Technical Data. Contact Details
Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have
More informationType: DILM12 10(24VDC) Article No.:
Type: DILM12 10(24VDC) Article No.: 276845 Ordering information Rated operational current AC 3 400 V I e A 12 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More information02/11/2015
DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage
More informationALLEN BRADLEY TIMING RELAY
ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY
More informationPluggable interface relays CR-M Miniature relays
2CDC 293 035 F0004 1 2 4 3 5 Features Standard miniature relays with mechanical status indication 12 different supply s: DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 125 V, 220 V AC versions: 24 V, 48 V,
More informationMinicontactorrelay,2NO/2NC,DCoperated
Minicontactorrelay,2NO/2NC,DCoperated Partno. DILER-22-G(24VDC) Articleno. 010042 CatalogNo. XTRM10A22TD Deliveryprogramme Product range DILER Mini-contactors Application Contactor relays Connection technique
More informationLC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC
Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category
More informationSeries CDP2 Definite Purpose Contactors
Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications
More informationAS09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional
More informationPluggable interface relays CR-M Miniature relays
2CDC 293 035 F0004 CR-M 1 2 4 3 5 Features Standard miniature relays with mechanical status indication 12 different supply voltages: DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 125 V, 220 V AC versions:
More informationMagnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A
72 Power Series SPDT 20 A; DPDT 15 A UL listed when used with proper Magnecraft sockets The 72 Plug-in Power relays offer clear or full-feature covers with multiple mounting options and accessories. Feature
More informationLC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil
Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationBimetal Temperature Switch
Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,
More informationLC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil
Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationAC diagonal module Ø 200 mm
max. 850 m /h C diagonal module Ø 00 mm Material: Housing: Plastic P Support bracket: Plastic P Impeller: Plastic P Rotor: Coated in black Number of blades: 7 Direction of air flow: "V" Direction of rotation:
More informationLC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationMovable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability
Compare These Features Built-in Shock bsorber Reduces contact bounce for longer life. Coil Dust Cover Keeps dust and dirt away from magnet and coil area. Coil Class B (1300 C Insulation System) with wide
More information.Power Distribution Center. PD-1. Instruction Manual
.Power Distribution Center. PD-1 Instruction Manual www.datavideo-tek.com 1 Contents Warnings and Precautions... 3 Warranty... 4 Standard Warranty... 4 Two Year Warranty... 4 Disposal... 4 Packing List...
More informationSeries CDP2 Definite Purpose Contactors
Series 2 Definite Purpose High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications including air
More informationLC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil
Product data sheet Characteristics LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil
Product data sheet Characteristics LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationSeries CT7N Bimetallic Overload Relays
Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor
More informationDatasheet - SRB-E-201ST
27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574
More informationClimatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC
Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with
More informationLC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil
Product data sheet Characteristics LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationDigital output modules
Appendix 374 Digital output modules Order number Figure Type DO 8xDC 24V 2A DO 16xDC 24V 1A DO 16xDC 24V 2A DO 16xDC 24V 0.5A manual operation General information Note - - - - Features 8 outputs, in groups
More informationCAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry
CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001
More informationSECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)
SECTION Counters & Timers (Analog / Digital) Laurel Hecon Simpson Yokogawa (YCA) Counters and Timers from the following manufacuturers are also available but not shown in catalog: Texmate Triplett (LFE)
More informationTECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT
RDP Customer Document TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT Doc. Ref CD1004L BS EN ISO 9001 Certificate No. FM13141 Affirmed by Declaration of Conformity USA & Canada RDP Electrosense
More informationDatasheet - SRB301LC 24VAC/DC
25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred
More informationInstruction Manual. Universal Flow Controller Model 261 / 261-EC-01
Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation
More informationGV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink
Characteristics TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Main Range Product name Device short name Product or component type Device application Trip unit technology Complementary Poles
More informationGV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals
Product datasheet Characteristics GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - spring terminals Main Range Product name Device short name Product or component type Device application
More informationData Sheet Definite Purpose Contactors Ex9CK Series
Data Sheet Ex9CK Series Ex9CK40B0 Ex9CKA10 na.noarkelectric.com NOARK Ex9CK Series Features Ex9CK Series DP Contactors provide high performance with both flexibility and reliability. They are designed
More informationLC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationGV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.
Product data sheet Characteristics GV2ME06 TeSys GV2-Circuit breaker-thermal-magnetic - 1...1.6 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationLC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationGV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.
Product data sheet Characteristics GV2ME04 TeSys GV2-Circuit breaker-thermal-magnetic- 0.4...0.63 A -screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationSafety dialogue solutions
Characteristics 5 Environment Conformity to standards Products XY2 CH, XY2 CE: EN/IEC 60947-5-1, EN/ISO 13850:2006, UL 508 and CSA C 22-2 n 14 (with suffi x H7) XY2 CB: EN/IEC 60947-5-1, EN/ISO 13850:2006,
More informationwith handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 25A power contactors silent CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning - Connection...
More informationGV2ME. Main. Device short name. Device application
Product datasheet Characteristics GV2ME32 TeSys GV2-Circuit breaker-thermal-magnetic - 24...32 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application
More informationLC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationOrdering details. Approval. Classification
Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMC1-A160 Circuit-breaker, 3p, 160A Part no. NZMC1-A160 Catalog No. 283296 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationType Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model
Low Signal Relay G6E Subminiature 7.87 H x.1 W x 16 L mm (0.31 H x 0.3 W x 0.63 L in). High sensitivity with pick-up coil power of 8 mw. Surge withstand meets FCC Part 68 rule and Telcordia 2.5 kv Specifications.
More informationRead/write head TN-CK40-H1147
Rectangular, height 40 mm Read/write head (5 positions) Plastic, PBT-GF30-VO Every read/write head can communicate with a number of different TURCK data carriers. Powered and operated only via BL ident
More information3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA
.5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................
More informationSINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry
More informationLighted Pushbutton Switch (Square) Ultra Bright LED Type
New Products Lighted Pushbutton Switch (Square) Ultra Bright LED Type Large Square-bodied Lighted Pushbutton Switches New models added with Ultra LEDs. New models with ultra bright LEDs added to single-screen
More information02/11/2015
24 x 48 Totalizers CTR24 non-backlit model Part number 87622062 Display : 8-digit LCD, height 8 mm Powered by a lithium battery Counter inputs : solid state (4-30 VDC) or voltage (10 260 VAC) Reset on
More informationLC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationSoft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit
DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer
More informationLC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationModular pulse operated latching relay 16 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,
More informationEMC Solutions Noise filtering
Power & Signal Quality TRABTECH EMC Solutions Noise filtering Interference-free power supply and signal transmission A permanent supply and safe data link are essential for the operational reliability
More informationHinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA
Hinges with built-in safety multiple switch SUPER ECHNO POLYMER IP RoHS PA +0-0 MAERIAL Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black or grey colour RAL 00 (C). Rotation pin: glass-fibre
More informationOperating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics
Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical
More informationDescription Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100
DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective
More informationElectronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de
More informationMagnetic Stirrers Magnetic Stirr
Magnetic Stirrers Heidolph Magnetic Stirrers Product Line features 0 0 0 D 1 1 K 1 K8 HG 1 HG 1 K 2 2 S8 4 safety P/N 503-000-00 504-00011-00 504-03010-00 504-00-00 504-10-00 504-10108-00 504-40000-00
More informationmulti-function meters
multi-function meters eclipse 2 eclipse 7 installation and operating manual 1 GENERAL DESCRIPTION 2 INSTALLATION 3 WIRING INFORMATION 4 2 ECLIPSE 2 METERS 2.1 PROGRAMMING THE METER 5 2.2 INFORMATION 6
More informationHigh performance circuit breakers
Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics
More informationProtective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A
DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective
More informationLC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Bảng thông số sản phẩm Đặc diểm LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationPROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS
INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationProtective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A
Deliveryprogramme Circuitbreak.3pselect.protection Partno. Articleno. 265777 NZMH4-VE1600 Product range Circuit-breaker Protective function Systems, cable, selectivity and generator protection Standard/Approval
More informationllen-bradley 194R-HM4-NFPA3
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationSINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS
SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical
More informationINNOVATION IN MAGNETICS DS3434/5. Mag612. Miniature Three-Axis Fluxgate Probe.
INNOVATION IN MAGNETICS DS3434/5 Mag612 Miniature Three-Axis Fluxgate Probe www.bartington.com Mag612 Miniature Three-Axis Fluxgate Probes Mag612 Miniature Three-Axis Fluxgate Probe This miniature fluxgate
More informationBulletin 190 IEC Modular Starter System
Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................
More informationI r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100
Circuit-breaker,3p,400A Partno. LZMC3-A400-I Articleno. 111955 Similar to illustration Deliveryprogramme Product range Circuit-breaker Protective function System and cable protection Standard/Approval
More informationType Contact form Model
Low Signal Relay G6A High sensitivity can be driven by digital circuits. Low-profile design allows use in.70 mm (0.50 in) PC board rack. Surge withstand meets FCC Part 68 regulation. Units can be mounted
More informationInterface Relays and Optocouplers Product group picture
Interface Relays and Optocouplers Product group picture /1 ABB Catalog 2CDC 1 004 C0208 Interface Relays and Optocouplers Table of contents Interface Relays and Optocouplers Interface Relays and Optocouplers
More informationGV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals
Product data sheet Characteristics GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic - 2.5...4 A - lugs-ring terminals Main Range Product name Device short name Device application Trip unit technology
More informationAbsolute Encoders Multiturn
The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft
More informationContactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B
Contactors Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business
More information10 PDUs 19 PDUs Zero-U PDUs
128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex - France Tel: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 www.legrand.com 10 PDUs Page 1. GENERL CHRCTERISTICS...1 2. EQUIPMENT ND PERFORMNCE...3
More informationCT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL
Obsolete Overload Cross Reference Series CT7/CT7K to Cross Reference CT7 CT7K Directly Mounts to Contactor... Adjustment Catalog Adjustment Catalog Adjustment Catalog Code Code Range (A) Number Range (A)
More information16 A and 25 A power contactors with or without handle
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 16 and 25 power contactors CONTENTS PGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning -
More informationFlexible Counter Series in DIN size 24 x 48 mm
Flexible Counter Series in DIN size 24 x 48 mm high contrast 8-digit LCD display or brilliant 6-digit LED display different supply voltages available: independent of mains supply with lithium battery or
More informationOperating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130
Operating Manual (Edition 04/2004) sinamics Line Reactors SINAMICS G130 Contents 1. Safety Information 2 2. General 5 3. Mechanical Installation 6 4. Electrical Installation 8 5. Technical Specifications
More informationAgency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B
11 Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business machines
More informationMaxiBridge mm Connectors. Ed Full-scale MaxiBridge 8 Pins Catalog E
MaxiBridge 2.54 mm Connectors Ed. 10 11.2014 Full-scale MaxiBridge 8 Pins Catalog E 074593 CABLE CONNECTOR SYSTEM GENERAL MaxiBridge Male and Female Connector The 2.54 mm single and dual row cable connector
More informationBUL1203EFP HIGH VOLTAGE FAST-SWITCHING NPN POWER TRANSISTOR
BUL1203EFP HIGH OLTAGE FAST-SWITCHING NPN POWER TRANSISTOR HIGH OLTAGE CAPABILITY LOW SPREAD OF DYNAMIC PARAMETERS MINIMUM LOT-TO-LOT SPREAD FOR RELIABLE OPERATION ERY HIGH SWITCHING SPEED FULLY INSULATED
More informationType: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles
Type: NZMN1 A100 Article No.: 259085 Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Description Rated current = rated uninterrupted current Setting range 3 pole I
More informationOnline data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS
Online data sheet SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS A B C D E F H I J K L N O P R S T Detailed technical data Features Technology Ordering information
More informationPower Circuit of a UL508A Panel. Typical UL489 Application
Typical UL489 Application Power Circuit of a UL508A Panel Disclaimer: This is an application example. Installation should be done by a qualified electrician under the guidance of UL specifications.. Altech
More informationProtection against direct contact Finger and back of hand proof to VDE 0106 Part 100
Circuit-breaker3psystems/cableprot. Partno. NZMB2-A250 Articleno. 259090 Deliveryprogramme Range Circuit-breaker Protective function System and cable protection Standard/Approval IEC Installation type
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationMIKRO POWER FACTOR CORRECTION COMPONENTS
MIKRO POWER FACTOR CORRECTION COMPONENTS MIKRO POWER FACTOR REGULATOR Steps 6, 8, 12, 14 Voltage 1 4V AC Frequency 0 and 60 Hz Detection method Displacement Power Factor Input current A Modes Automatic,
More information