h c HUNG CHANG D IBM PC 586, Pcntium Software Drive : Windows 95 Dual Clmnel Sampling per channel : 100 MS/s
|
|
- Meghan McCormick
- 5 years ago
- Views:
Transcription
1 h c HUNG CHANG Hongjc Bldg , Hongje-dong. Seodaemun-ku, Seoul, Korea TEL : FAX : D IBM PC 586, Pcntium Software Drive : Windows 95 Dual Clmnel Sampling per channel : 100 MS/s m Auto setup D Auto Calibration Memory Depth : 32K byte/cl-l
2 PC BASED DSO 2100 How To.... Installing software Installing hardware Auto Setup Guide to operations Screen Auto Calibration Probe Calibration FFT XY plot Hardware Specifications Commands File menu View menu Help menu
3 Installing software 1. Insert the distribution disk into CD drive. 2. Run Windows. 3. Select File menu. 4. Select Run option. 5. Enter file to run CD:\Install.exe 6. Follow the on screen instructions.
4 Installing hardware Please follow these instructions for installing the PC BASED DSO ) Connect the DSO to the provided cable. 2) Connect the cable to the parallel port of your computer. 3) Connect the Oscilloscope probe to the BNC connector (CH.A) and connect the probe tip to the CAL terminal on the back of the DSO 4) Connect the power cable to the DSO. 5) Plug the power adapter into the wall. 6) After checking all connections, turn on the computer and peripherals. You are now ready to install the software. 7) After installing the software, calibrating the scope probes is a good idea. See the section below on hardware, the Calibration Procedure
5 Auto setup Auto setup operates on the analog channel that is currently defined as the trigger channel. It will attempt to find setting that provide a stable and consistent acquisition. Auto setup will<<auto setup>> on the following settings Voltage/Division for trigger channel. When you dual mode, Auto setup is selected to CH.A
6 Guide to operations When making measurements with the PC BASED DSO Digital Storage Oscilloscope, meaningful data can only be captured with some prior knowledge of the characteristics of the circuit under test. Before initiating any capture cycles, the PC BASED DSO must be configured using the control program. See the software section later in the manual for instructions on these procedures. To connect the PC BASED DSO to the test circuit, there are two standard BNC probes, one for each Analog input channel The scope probes have removable hook clips on their ends and an attached alligator clip for the signal ground connection. Make sure that there is a common ground between the PC BASED DSO 2100 and the circuit under test. Each Analog channel probe has a calibration adjustment. It is important that this calibration be made at least twice a year. See Auto Calibration for more information.
7 Screen. Main Screen Zero Point Tick Mark Cursors A and B Horizontal Scroll Bar Display Time A Tireger Menu Parmater Display
8 Main Screen The main display is made up of areas: - On the right side of the screen is the settings/parameter display. - In the middle are the data displays. - The top is the analog waveform display. - Above the analog display is a Time A graph representing the data buffer. This also shows the location of the cursors and which part of the buffer is being displayed. - On the right side of the screen you will see the settings for one of the analog channels. You can select the active channel with the select button. - Just to the left of the analog waveform display are markers for the ground points. CH-A markings are closest to the display, than CH-B. Time A The Time A Graph display represents the data buffer. The graph shows the locations of Cursor A, Cursor B, and the Trigger cursor, and also the current portion of the buffer displayed on the screen. Each item is displayed in its color. If Thumbnails are turned on a miniature waveform is displayed, otherwise a horizontal line is displayed for each channel.
9 Zero Point Tick Marks Located to the right of the Analog Display. The Zero Point Tick Marks are > shaped. These display the ground points of each analog channel. Zero Point Tick Marks associated with Channel A are left most and Channel B through Display are successively further to the left. These Tick Marks can be moved by click of mouse by grabbing and dragging with a pointing device
10 Cursors A and B The Cursors provide an easy means of voltage or time-and-frequency measurements. For a selected channel, the voltage or time-and-frequency difference between the two cursors is shown in the Parameters Display area. Cursor A and Cursor B can be moved by: - Grabbing and dragging the cursors with a pointing device. - Selecting the Cursor by clicking on the Cursor A or Cursor B button. - Selecting the cursor from the mouse.
11 Display Time A Shows or hides the display of the analog waveform in the Time A Graph area. A Time A display is a compressed version of the main display that shows a complete view of the data buffer. With Time A off, a line is displayed with a bar at each end that depicts relative position of each displayed channel. A box is drawn to depict the area that is displayed by the full-size window, that box is the same color as the grid. The cursor positions are also displayed. Note: Turning this off will speed up the initial display of data.
12 Horizontal Scroll Bar This scroll bar is used in conjunction with a selected waveform. The Horizontal Scroll Bar will move a selected waveform or cursor left or right in the display area.
13 Trigger menu Trigger settings Source Slope Couple Mode menu commands ~..
14 Trigger settings All trigger and capture parameters are displayed in this box and can be altered in it as well. These parameters are also accessible through the pull down menus. Source Set trigger channel. Slope Set trigger slope. Mode Set trigger mode. See also Trigger Basics.
15 . Source Trigger CH- 1 Trigger on channel 1. Trigger CH-2 Trigger on channel 2. Trigger EXT Trigger on channel EXT
16 Trigger Slope -- When the trigger channel is set to one of the analog channels. Trigger Slope can be set to positive(rising) or negative(falling) edge.
17 Couple Mode menu commands The trigger mode can be set in the trigger dialog box to the following: Normal Trigger on a rising or falling edge at a certain level AC TV Horizontal Trigger on Horizontal TV signal. TV Vertical Trigger on Vertical TV signal.
18 Parameter Display The Parameters Display shows the following: Coupling (for selected channel) V/Div (for selected channel) Probe settings ( for selected x10, xl ) Cursor measurements Time Voltage Frequency Clicking on the Select button will change which channel is selected. Clicking on the display channel button on the toolbar will change which channel is selected. Clicking on the Edit button allows the user to change settings for the selected channel.
19 Probes Calibration For the most accurate measurements possible, the probes used must be calibrated. There is a built in calibration signal point on the CAL terminal connector. Follow this procedure to calibrate each probe: 1) 1) Verify that the probe attenuation setting matches the actual probe 2) Connect the probe (BNC end) to the channel A or channel B inputs. 3) Connect the scope probe tip (pointy end) to the CAL terminal connector by holding the probe s tip against the calibration point. A Square wave signal should appear on the screen 4) Adjust the probe calibration(a screw adjustment near tip) until a true square wave is shown on the screen, noting the comers of the waveform which should be sharp and square, not rounded over or peaky Auto Calibration Auto Calibration of the PC BASED DSO hardware is performed by the software each time it is started up. This ensures that the hardware is fnnctioning correctly before each use. While the tests are being performed, the following window showing a list of each test is displayed.
20 FFT The FFT dialog allows control and display of FFT s. The following controls are available: Horizontal zoom Select horizontal zoom ratio. Vertical scale Select vertical scaling factor.
21 XY Plot XY Plot will display the buffer data with one channel of data as the X axis data and another channel of data as the Y axis data. This mode duplicates the XY Plots commonly found on analog oscilloscopes. The radio buttons on the right side of this dialog box select which channel of data will be used for the X axis and Y axis.
22 . Hardware Specifications CLOCK SPECIFICATIONS Internal Frequency : 1 Hz to 30 MHz Timebase: 50ns to 320s / Division displayable, Scroll mode to 1s ANALOG INPUT SPECIFICATIONS Input of Channels : CH.A, CH.B Input Voltage Sensitivity: Probe 1:l lomv/div to 5Vldiv Probe 10: mv / div to 50 V / div Input Impedance analog channels : 1 M ohm shunted by 25 pf Absolute Max. Input Voltage: OV continuous and 250 V (DC + AC < 10 KHz) Transient. Usable Input Voltage Range : Trigger: Horizontal mode: 5ov Positive or Negative Slope adjustable level. Auto Normal TV horizontal TV vertical Single Normal Auto MEMORY Data Acquisition Memory Modes. Memory Size: 32WCH. Minimum required: a minimum of 4 Mbytes RAM is necessary to use the DSO control program. DISPLAY Cursors: There are two cursors. Cursor-A and Cursor-B they are both time and voltage or frequency cursors. They can be moved using the horizontal and vertical scroll bars or by grabbing and dragging them. Differences are automatically calculated and displayed on the screen.
23 File menu commands The File menu offers the following: Data Load Load file. Data, settings. Select which channels to load. Data Save Save file. Data, settings. Graph Save to picture Graph copy clipboard Print Prints data. Exit Exit PC BASED DSO software
24 View menu commands The View menu offers the following: Grid Show or hide grid on analog display. Cursor Quickly moves Cursors onto display window. Independent Scrolling Select channel for independent movement. Lines Displays connections between analog data points only (fastest). Dots Displays the analog data points only. Time A Shows a compressed version of the entire buffer directly below the toolbar.. FFT Display FFT window. XY Plot Display XY plot..
25 Help menu commands The Help menu offers the following commands, which provide you assistance with this application: Using Help Provides general instructions on using help. About Displays the version number of this application.
26 fised DSO 2100 PC BASED DIGITAL STORAGE OSCM LOSCOPE Iyg HUNG CHANG hungchangxam
27 This chapter introduces you to the PC BASED DSO 2100 program and provides specifications for the PC BASED DSO It is divided into two sections as follows; Introduction Suyportcd Hardware Provides a general produrt dcscriytion Prozridcs spwyficatinns for the follozuirzg scope cnrd 21 Oil Digital Storage Oscilloscope. PC BASED DSO 2100 is a powerful software package for controlling the PC BASED DSO 2100 IBM PC-based oscilloscope. The program allows multiple boards to operate together to perform simultaneous data acquisition on up to 2 different channels as rate as high as 10OMS/s. The user has complete control of all capture and display feature. As many as 2 channels can be viewed together on the I C screen, and signals and system setups can be saved to disk for future use. PC BASED DSO 2100 requires a VGA monitor and graphics adapter and will make use a numeric co-prosessor, if present. Display screens can be printed to the printer that supported to the windows 95
28 This instrument is installation category( Over Voltage Category) : II If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired. Power off : Remove the power cable from DC input jack Symbol Guide A : Caution ( refer to accompanying documents ) zz : Direct current h : Frame or chassis terminal
29 Minimum System : IBM PC 586, I entium or compatible with 8MB of RAM Requirements (Recommend 16MB); VGA graphics card and monitor; and at least 10 MB of free hard disk space. Scope card board must be present in the system to acquire data. At windows 95 software. Print Port : ECI? EPI? Nomal. Mode. PC Connection : Parallel Power : DC -+I- 8 V, (+/-lo%) 0.8/0.2 A Environmental Conditions : 0 C - 40 C indoor use, Altitude up to 2000 m 50% -8O%RH Time Range Cursors Vertical Mode Horizontal Mode Grid Zoom X-Y Mode Coupling Input Range Scroll Mode 5 ns/div to 1 Hour/div l-2-5 -step. (Scroll mode to 1s) av and AT CH A/CH B/ DUAVADD/SUB Auto/Nor&Single on/off Voluntary Screen AC, TV-V/H 10 mv/div to 5 VfDIV l Step 1 s/div--1 Hour/div
30 Inputs per scope Sample Rate Memory Bandwidth Resolution Amplitude Auto Setup Connector Impedance Auto CAL External Depth calibration card 2 CH A : 100 MS/s, CF I B : 100 MS/s, DUAL : 100 MS/s 32 KB/CH 30 MHz 8 bits Max 250 V + pk 50 Hz to 30 MHz BNC lmr,25pf Gain Accuracy :i 3% lkhz2v Max 100 V+pk Trigger Source Trigger Slope Trigger Type CHlICH2JEXT Positive or Negative Analog
31 Channel 2 Spectral range 0 Hz-50 MHz Horizontal Zoom Select Horizontal zoom ratio Vertical Scale Select vertical scaliry factor Hard copy Materials Supplied The printer that supported to the windows 95 PC BASED DSO 2100 Installation CD Software Drives Available as a DLL for the windows 95 environment for Visual C and Visual Basic Dimensions Weight 225(H)x125(W)x35mm(D) 400 g approx Warrants that this product will be free from defects in materials and workmanship for a period of one(l) year from the lute of shipment.
32 PC BASED DSO AC Adapter PC Interface Cable 1 Set KNV-1615, AC 230 V, 50 Hz, 150 ma (Output : DC +/-8 V, l/ia) HYOSUNG, 1 Eh 1 EA Probe 2EA [I; the surface of the case is dirty rub the affected area lightly with a soft cloth soaked in light natural detergent To avoid electric shock, No operator serviceable parts inside refer servicing qualified service personnel.
33 This chapter describes the installation procedure for the PC BASED DSO 2100 program and for the PC BASED DSO You will perform the following steps; 1) Connect the DSO to the provided cable 2) Connect the cable to the parallel port of your computer. 3) Connect the oscilloscope probe to the BNC connector(c1-i.a) and connect the probe tip to the cal terminal on the back of the DSO. 4) Connect the power cable to the DSO. 5) Plug the power adapter into the well 6) This instrument is designed for natural-aucooling There should be space at least 3Cm from left, right side of the instrument To install the PC BASED DSO 2100 program on your PC, select the appropriate CD for your computer s CD drive.. Inscrf fire &tribrrfion CD info driac CD. fl Rirf~ zuidozus. H Select File rrrerrrl. m Select RWI 0pfion.. Eflfcrfile to run [ CD drive ] : setup. exe Follom fire 011 screcrr insfrzrcfion.
34 ADAPTER PC
Oscilloscope Guide Tektronix TDS3034B & TDS3052B
Tektronix TDS3034B & TDS3052B Version 2008-Jan-1 Dept. of Electrical & Computer Engineering Portland State University Copyright 2008 Portland State University 1 Basic Information This guide provides basic
More informationPRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment
Integrated Component Options Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment PRELIMINARY INFORMATION SquareGENpro is the latest and most versatile of the frequency
More informationExpect to Make Waves.
Expect to Make Waves. The New Oscilloscope Large 10.4" LCD touch screen Long capture time Extensive communication capabilities www.lecroy.com The New Oscillos From its large 10.4" LCD touch screen to its
More informationDigital Storage Oscilloscopes 2550 Series
Data Sheet Digital Storage Oscilloscopes 2550 Series The 2550 series digital storage oscilloscopes provide high performance and value in 2-channel and 4-channel configurations. With bandwidth from 70 MHz
More informationMSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer
Link Instruments Innovative Test & Measurement solutions since 1986 Store Support Oscilloscopes Logic Analyzers Pattern Generators Accessories MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer $ The
More informationScopeMeter 190 Series Specifications
Seite 1 von 7 ScopeMeter 190 Series Specifications Product Home Features Specifications Models, Options & Accessories Oscilloscope Mode Meter Mode Recorder Mode General Specifications Oscilloscope Mode
More informationRIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.
RIGOL Data Sheet Product Overview DS1000B series oscilloscopes are designed with four analog channels and 1 external trigger channel, which can capture multi-channel signal simultaneously and meet industrial
More informationMINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure
MINI PC SCOPE PCSU01 User manual Features test leads software download USB cable design enclosure Specifications oscilloscope: o bandwidth: DC to 200 khz ± 3 db o input impedance: 100 ko / 20 pf o maximum
More informationS op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s
ET 150 Scope Controls Learning Objectives In this lesson you will: learn the location and function of oscilloscope controls. see block diagrams of analog and digital oscilloscopes. see how different input
More informationQuick Start. RSHS1000 Series Handheld Digital Oscilloscope
Quick Start RSHS1000 Series Handheld Digital Oscilloscope General Safety Summary Carefully read the following safety precautions to avoid personal injury and prevent damage to the instrument or any products
More informationBurlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix
v1.2 Burlington County College INSTRUCTION GUIDE for the Hewlett Packard FUNCTION GENERATOR Model #33120A and Tektronix OSCILLOSCOPE Model #MSO2004B Summer 2014 Pg. 2 Scope-Gen Handout_pgs1-8_v1.2_SU14.doc
More informationSMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.
9310A Family Digital Oscilloscopes 400 MHz Bandwidth, 100 MS/s Main Features Two and Four Channel Versions 50k, 200k and 1M Point Records DOS Compatible Floppy Disk, PCMCIA portable hard drive and Memory
More informationWAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value
WAVEJET 300 SERIES OSCILLOSCOPES New Cover to Come Unmatched Performance, Portability, and Value ALL THE TOOLS YOU NEED Automatic Measurements Save time making measurements on your signals by using the
More informationPlease feel free to download the Demo application software from analogarts.com to help you follow this seminar.
Hello, welcome to Analog Arts spectrum analyzer tutorial. Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. For this presentation, we use a
More informationEmbest DSO2300. Feature. General Description:
Embest DSO2300 Feature General Description: DSO2300 is an intelligent two-channel PC based USB digital storage oscilloscope with high performance. It runs on any USB1.1 or USB2.0 equipped PC using Windows
More information2016 RIGOL TECHNOLOGIES, INC.
RIGOL Data Sheet Product Overview DS1000B series oscilloscopes are designed with four analog channels and 1 external trigger channel, which can capture multi-channel signal simultaneously and meet industrial
More informationWAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value
WAVEJET 300 SERIES OSCILLOSCOPES Unmatched Performance, Portability, and Value 1 WAVEJET 300 SERIES Unique Capabilities in a Low Bandwidth Oscilloscope The WaveJet 300 Series features unmatched performance
More informationPicoScope 6407 Digitizer
YE AR PicoScope 6407 Digitizer HIGH PERFORMANCE USB DIGITIZER Programmable and Powerful 1 GHz bandwidth 1 GS buffer size 5 GS/s real-time sampling Advanced digital triggers Built-in function generator
More informationReference. TDS7000 Series Digital Phosphor Oscilloscopes
Reference TDS7000 Series Digital Phosphor Oscilloscopes 07-070-00 0707000 To Use the Front Panel You can use the dedicated, front-panel knobs and buttons to do the most common operations. Turn INTENSITY
More informationDIGITAL OSCILLOSCOPES & DIGITAL SCOPES
7050/7050/70505/7055 Digital Oscilloscopes DL540/DL540L/DL50/DL50L FUNCTIONS SIGL OBSERVATION USING LONG MEMORY Capturing Signals Using Long Memory for Accurate Waveforms The DL50/DL540 can continuously
More informationSDS1000C Specifications
SDS1000C Specifications File Version V1.2 Siglent technology Co., Ltd CHARACTERISTIC: The highest Single real-time sampling rate can be up to 500MHzsa/s; Equivalent sampling rate is up to 10GSa/s. Memory
More informationTechnical Reference. TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications
Technical Reference TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications 070-8990-04 Please check for change information at the rear of this manual. Fifth
More informationUser s Manual. GAO-DSO25216A Digital Storage Oscilloscope with Logic Analyzer, FFT Spectrum and Counter. Revision Software Win98/me/2000/xp Version
User s Manual GAO-DSO25216A Digital Storage Oscilloscope with Logic Analyzer, FFT Spectrum and Counter Revision Software Win98/me/2000/xp Version Table Of Contents (DSO-25216A) Item Checklist... 3 Installing
More informationPicoScope 6407 Digitizer
YE AR HIGH PERFORMANCE USB DIGITIZER Programmable and Powerful 1 GHz bandwidth 1 GS buffer size 5 GS/s real-time sampling Advanced digital triggers Built-in function generator USB-connected Signals Analysis
More informationSX-METRO A software package to meet all your needs
SX-METRO A software package to meet all your needs SX-METRO Software Front panel contact software The OX 863 and the OX 803 can be fitted with an RS232 interface (option) for controlling and programming
More informationManual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.
Manual Title: 9500B Users Supplement Issue: 2 Part Number: 1625019 Issue Date: 9/06 Print Date: October 2005 Page Count: 6 Version 11 This supplement contains information necessary to ensure the accuracy
More information~.Yr / 12. Offset range: ±2 V (2 mv/div to 200 mv/div), ±SO V (> 200 mv/div to 5 V/div) "digital storage oscilloscope" 13.
-", " ; ~~~\_:;Jc:::~r ~.Yr / ~ jlf+ll t""'1 JJaJI..:.IWI."..JI 1. Analog bandwidth (-3dB ): 100 MHz 2. Analog input channels: 2 3. Calculated rise time: :5 3.5 ns 4. Time base range: 5 ns/div to 50 s/div
More informationAnalog Arts SA985 SA975 SA935 SA915 Product Specifications [1]
www.analogarts.com Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1] 1. These models consist of an oscilloscope, a spectrum analyzer, a data recorder, and a frequency & phase meter. Oscilloscope/
More informationSpectrum Analyser Basics
Hands-On Learning Spectrum Analyser Basics Peter D. Hiscocks Syscomp Electronic Design Limited Email: phiscock@ee.ryerson.ca June 28, 2014 Introduction Figure 1: GUI Startup Screen In a previous exercise,
More informationPC Oscilloscope Spectrum Analyzer Logic Analyzer
PC Oscilloscope Spectrum Analyzer Logic Analyzer DSO-29xxA&B Series User s Manual Revision I http://www.clock-link.com.tw Associates Contents...4 Install Hardware...4 Install Software...4 Guide to operation...4
More informationPortable Performance for Debug and Validation
WaveJet 300A Oscilloscopes 100 MHz 500 MHz Portable Performance for Debug and Validation A UNIQUE TOOLSET FOR PORTABLE OSCILLOSCOPES Key Features 100 MHz, 200 MHz, 350 MHz and 500 MHz bandwidths Sample
More informationPicoScope PC Oscilloscopes. User's Guide. ps2203.en r4 Copyright Pico Technology Limited. All rights reserved.
PicoScope 2203 PC Oscilloscopes User's Guide PicoScope 2203 User's Guide I Contents 1 Welcome...1 2 Introduction...2 1 Using this guide 2 Safety symbols 3 Safety warning 4 FCC notice 5 CE notice...2...2...3...4...4...5
More informationDataSheet. SDS1000DL Series Digital Oscilloscope
DataSheet SDS1000DL Series Digital Oscilloscope CHARACTERISTIC: The highest Single real-time sampling rate can be up to 500MHzsa/s; Equivalent sampling rate is up to 50GSa/s. Memory Depth: 32Kpts Trigger
More informationAnalog Arts SA985 SA975 SA935 SA915 Product Specifications
Analog Arts SA985 SA975 SA935 SA915 Product Specifications Oscilloscope/ Spectrum Analyzer/ Data Recorder Model SA985 SA975 SA935 SA915 Oscilloscope (Typical by Design) Bandwidth (Max at probe tip) [1]
More informationNanoGiant Oscilloscope/Function-Generator Program. Getting Started
Getting Started Page 1 of 17 NanoGiant Oscilloscope/Function-Generator Program Getting Started This NanoGiant Oscilloscope program gives you a small impression of the capabilities of the NanoGiant multi-purpose
More informationimso-104 Manual Revised July 19, 2012
imso-104 Manual Section 1 Getting Started SAFETY 1.10 Quickstart Guide 1.20 SAFETY 1.30 Compatibility 1.31 Hardware 1.32 Software Section 2 How it works 2.10 Menus 2.20 Analog Channel 2.21 On / Off 2.22
More informationUniversity of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope
University of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope Name:, A. Stolp, 2/2/00 rev, 9/15/03 NOTE: This is a fill-in-the-blanks lab. No notebook is required. You are encouraged
More informationOverview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators
Know Your Oscilloscope Overview Front Panel Sharing Agilent s Resources with Engineering Educators www.educatorscorner.com Horizontal (time) controls Run control Special purpose menus/controls Trigger
More informationBeginners How to Test DSO138mini
Beginners How to Test DSO138mini You have finished assembling your DSO138mini kit. You may be anxious to see it works. But you might not be familiar with oscilloscope and you could encounter unexpected
More informationTablet Oscilloscope Quick Guide
Tablet Oscilloscope Quick Guide For tbook Series Shenzhen Micsig Instruments Co., Ltd. Copyright Copyright Shenzhen Micsig Instruments Co., Ltd. All Rights Reserved. Version Version: MKX2014-001; Product
More informationEMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C
A Electric Power / Controls 2 kw EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C GENERAL DESCRIPTION The Lab-Volt Data Acquisition and Management for Electromechanical Systems (LVDAM-EMS),
More informationPicoScope 4000 Series PC Oscilloscopes
PicoScope 4000 Series PC Oscilloscopes User's Guide -1 Contents I Contents 1 Welcome...1 2 Introduction...2 1 Using this guide 2 Safety symbols 3 Safety warning 4 FCC notice 5 CE notice...2...2...2...3...3...3
More informationFOUR CHANNEL USB RECORDER PCRU01. User manual. Table of Contents
FOUR CHANNEL USB RECORDER PCRU01 User manual Table of Contents Features 2 Specifications 2 hardware 2 software: 2 system requirements 2 Software installation 2 SAFETY and WARNINGS 3 Warranty 3 Connections
More informationTDS 520B, TDS 540B, TDS 620B, TDS 644B, TDS 680B, TDS 684B, TDS 724A, TDS 744A, & TDS 784A
Technical Reference TDS 520B, TDS 540B, TDS 620B, TDS 644B, TDS 680B, TDS 684B, TDS 724A, TDS 744A, & TDS 784A Digitizing Oscilloscopes Performance Verification and Specifications 070-9384-01 Copyright
More information50 MHz Digital Storage Oscilloscope
DSC-5300 50 MHz Digital Storage Oscilloscope Applications The DSC-5300 Series Signal Generators are ideally suited for applications where value and quality are equally important such as for: zeducational
More informationATS MS/s 8-Bit PCI Digitizer
2 channels sampled at 8-bit resolution 50 MS/s simultaneous real-time sampling rate on each input ±20mV to ±20V input range 256 Kilo samples of on-board acquisition memory per channel AlazarDSO Oscilloscope
More informationExperiment 13 Sampling and reconstruction
Experiment 13 Sampling and reconstruction Preliminary discussion So far, the experiments in this manual have concentrated on communications systems that transmit analog signals. However, digital transmission
More informationPicoScope 2000 Series PC Oscilloscopes
PicoScope 2000 Series PC Oscilloscopes User guide I PicoScope 2000 Series User Guide Table of Contents 1 Introduction...2...2 1 Overview...2 2 Safety symbols...3 3 Safety warning...3 4 FCC notice 5 CE
More informationME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition
ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition INTRODUCTION Many sensors produce continuous voltage signals. In this lab, you will learn about some common methods
More informationAgilent Technologies 54522A
Agilent Technologies 54522A Data Sheet Product Specifications General Specifications Maximum Sample Rate 54522A 2 GSa/s Number of Channels (all are simultaneous acquisition) 54522A: 2 Record Length 32,768
More informationimso-104 Manual Revised August 5, 2011
imso-104 Manual Revised August 5, 2011 Section 1 Getting Started SAFETY 1.10 Quickstart Guide 1.20 SAFETY 1.30 Compatibility 1.31 Hardware 1.32 Software Section 2 How it works 2.10 Menus 2.20 Analog Channel
More informationDataSheet SDS1000CML Series Digital Oscilloscope
DataSheet SDS1000CML Series Digital Oscilloscope CHARACTERISTIC: The highest Single real-time sampling rate can be up to1gsa/s; Equivalent sampling rate is up to 50GSa/s. Memory Depth: 2Mpts Trigger types:
More informationDataSheet SDS1000CFL Series Digital Oscilloscope
DataSheet SDS1000CFL Series Digital Oscilloscope CHARACTERISTIC: The volume of the oscilloscope is cabinet and it is portable 7 Color TFT LCD display 2/4 channels, Bandwidth: 70MHz-300 MHz Single real-time
More informationINSTRUCTION GUIDE. for the. Keysight (formally Agilent; Hewlett-Packard) Model #33509B. and. Tektronix. Fall 2017
v3 INSTRUCTION GUIDE for the Keysight (formally Agilent; Hewlett-Packard) WAVEFORM GENERATOR Model #33509B 33500 Series and Tektronix OSCILLOSCOPE Model #MSO2004B Fall 2017 Pg. 2 Scope-Gen Handout_part
More informationWorking with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I
Working with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I Prepared by: Kyle Botteon Questions? kyle.botteon@psu.edu 2 Background Information Recall that oscilloscopes (scopes)
More informationADS1000C, CAL / CML Series
ADS1000C, CAL / Series DIGITAL STORAGE OSCILLOSCOPE 25MHz, 40MHz, 60MHz, 100MHz, 150MHz, 200MHz ADS1000 C Series ADS1000 CAL/ FEATURES APPLICATIONS 500MSa/s & 1GSa/s Sampling Rate 2 Channels 7 Widescreen
More informationMIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003
MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 OBJECTIVE To become familiar with state-of-the-art digital data acquisition hardware and software. To explore common data acquisition
More informationPC Scope PCS64i. PCS64i POWER DC ON AC
PC Scope PCS64i CH1 CH2 PCS64i DC POWER DC AC 100Vp max. ON 100Vp max. AC CONTENTS 5 DIAGRAMS & SERVICE INFO 32 2 VELLEMAN KIT NV Legen Heirweg 33 9890 Gavere Belgium Internet Web-Site: http://www.velleman.be
More informationExperiment # 4 Counters and Logic Analyzer
EE20L - Introduction to Digital Circuits Experiment # 4. Synopsis: Experiment # 4 Counters and Logic Analyzer In this lab we will build an up-counter and a down-counter using 74LS76A - Flip Flops. The
More informationChoosing an Oscilloscope
Choosing an Oscilloscope By Alan Lowne CEO Saelig Company (www.saelig.com) Post comments on this article at www.nutsvolts.com/ magazine/article/october2016_choosing-oscilloscopes. All sorts of questions
More informationElectrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)
2141274 Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University Cathode-Ray Oscilloscope (CRO) Objectives You will be able to use an oscilloscope to measure voltage, frequency
More informationQuick Start. SHS1000 Series Handheld Digital Oscilloscope QS03010-E02B 2015 SIGLENT TECHNOLOGIES CO., LTD
Quick Start SHS1000 Series Handheld Digital Oscilloscope QS03010-E02B 2015 SIGLENT TECHNOLOGIES CO., LTD Guaranty and Declaration Copyright SIGLENT TECHNOLOGIES CO., LTD. All Rights Reserved. Trademark
More informationPORTABLE OSCILLOSCOPE
PORTABLE OSCILLOSCOPE Model OX 7104-CK 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Five complementary tools in one: Oscilloscope, Multimeter, FFT Analyzer, Harmonic Analyzer
More informationAnalog Discovery Scope and Waveform Generator Edited 11/15/2016 by Eric Scotti & DGH
Analog Discovery Scope and Waveform Generator Edited 11/15/2016 by Eric Scotti & DGH Specifications The Analog Discovery contains several devices but we will likely only use the 2 channel oscilloscope
More informationPC Scopes PCS500 PCS100 / K8031. CHECK THE Pc-Lab2000 TM GETTING STARTED GUIDE FOR SOFTWARE INSTALLATION
PC Scopes PCS500 PCS100 / K8031 CHECK THE Pc-Lab2000 TM GETTING STARTED GUIDE FOR SOFTWARE INSTALLATION Reference Manual VELLEMAN Instruments is a division of VELLEMAN Components NV Legen Heirweg 33 9890
More informationWhat to look for when choosing an oscilloscope
What to look for when choosing an oscilloscope Alan Tong (Pico Technology Ltd.) Introduction For many engineers, choosing a new oscilloscope can be daunting there are hundreds of different models to choose
More information4CH/2CH Digital Storage Oscilloscopes
Model: 2553, 2555, 2556, 2557, 2558, 2559 4CH/2CH Digital Storage Oscilloscopes USER MANUAL Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be
More informationPicoScope. User guide. Copyright 2005 Pico Technology Limited. All rights reserved. PSW044 v1.5
PicoScope User guide I PicoScope User Guide Table of Contents 1 Introduction...3...3 1 What is PicoScope?...3 2 Why use PicoScope?...4 3 Screen layout...4 4 Display area...5 5 Customisation...5 6 Exporting
More informationPicoScope 4000 Automotive PC Oscilloscopes
PicoScope 4000 Automotive PC Oscilloscopes User's Manual ps4000a.en-1 Copyright 2008 Pico Technology Ltd. All rights reserved. Contents I Contents 1 Introduction...1 1 Overview...1...1 2 Minimum PC requirements...2
More informationInstrument Firmware Release Notes
odels DS2072, DS2102, DS2202, DS2072A, DS2102A, DS2202A, DS2302A, DS2072A-S, DS2102A-S, DS2202A-S, DS2302A-S, SO2072A, SO2102A, SO2202A, SO2302A, SO2072A-S, SO2102A- S, SO2202A-S, SO2302A-S Version Information
More informationSigPlay User s Guide
SigPlay User s Guide . . SigPlay32 User's Guide? Version 3.4 Copyright? 2001 TDT. All rights reserved. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or
More informationSNG-2150C User s Guide
SNG-2150C User s Guide Avcom of Virginia SNG-2150C User s Guide 7730 Whitepine Road Revision 001 Richmond, VA 23237 USA GENERAL SAFETY If one or more components of your earth station are connected to 120
More information2 MHz Lock-In Amplifier
2 MHz Lock-In Amplifier SR865 2 MHz dual phase lock-in amplifier SR865 2 MHz Lock-In Amplifier 1 mhz to 2 MHz frequency range Dual reference mode Low-noise current and voltage inputs Touchscreen data display
More informationModel P2016. Dual Channel Handheld Digital Storage. Oscilloscope & Multimeter. Quick Scope Guide
Model P2016 Dual Channel Handheld Digital Storage Oscilloscope & Multimeter Quick Scope Guide General Warranty BNC warrants that the product will be free from defects in materials and workmanship for 3
More informationPicoScope 3000 Series Automotive User guide
PicoScope 3000 Series Automotive User guide PS3000A044 v1.0 I PicoScope 3000 Series Automotive PC Oscilloscopes Table of Contents 1 Introduction...2...2 1 Overview...2 2 Minimum PC requirements...2 3 Installation
More informationM570 series oscilloscope User s Guide Version 1.02
Version 1.02 Copyright 2004-2006 ETC s.r.o. Thank you for choosing oscilloscope from M570 series, a product of ETC s.r.o. We believe it will fulfill your expectations. In order to assure that we will be
More information25 MHz Digital Storage Oscilloscope
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model: 2530B 25 MHz Digital Storage Oscilloscope USER MANUAL Safety Summary The
More informationAnalyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note
Analyze Frequency Response (Bode Plots) with R&S Oscilloscopes Application Note Products: R&S RTO2002 R&S RTO2004 R&S RTO2012 R&S RTO2014 R&S RTO2022 R&S RTO2024 R&S RTO2044 R&S RTO2064 This application
More informationLogic Analyzer Auto Run / Stop Channels / trigger / Measuring Tools Axis control panel Status Display
Logic Analyzer The graphical user interface of the Logic Analyzer fits well into the overall design of the Red Pitaya applications providing the same operating concept. The Logic Analyzer user interface
More informationLab 2: A/D, D/A, and Sampling Theorem
Lab 2: A/D, D/A, and Sampling Theorem Introduction The purpose of this lab is to explore the principles of analog-to-digital conversion, digital-to-analog conversion, and the sampling theorem. It will
More informationUniversity of Utah Electrical Engineering Department EE1050/1060 Oscilloscope. Name:, Lab TA:
University of Utah Electrical Engineering Department EE1050/1060 Oscilloscope Name:, Lab TA: A. Stolp, 2/2/00 rev, 9/14/00 NOTE: This is a fill-in-the-blanks lab. No notebook is required. You are encouraged
More informationLeCroy Digital Oscilloscopes
LeCroy Digital Oscilloscopes Get the Complete Picture Quick Reference Guide QUICKSTART TO SIGNAL VIEWING Quickly display a signal View with Analog Persistence 1. Connect your signal. When you use a probe,
More informationSDS 1072/1074CFL / SDS 1102/1104CFL SDS 1202/1204CFL / SDS 1302/1304CFL Digital Storage Oscilloscopes 70MHz / 100MHz / 200MHz /300MHz
SDS 1072/1074CFL / SDS 1102/1104CFL SDS 1202/1204CFL / SDS 1302/1304CFL Digital Storage Oscilloscopes 70MHz / 100MHz / 200MHz /300MHz Features 500MSa/s & 1GSa/s Sampling Rate 2 Channels / 4 Channels 7
More informationUser Manual. Digital Oscilloscope V1.9
User Manual Digital Oscilloscope V1.9 Declaration All rights reserved. Contents in this Manual are not allowed to copy, extract and translate before being allowed by the company. Brief Introduction Characteristic:
More information1 scope channel. 2 scope channels* 200 MSa/s 4 MB memory/ch. 200 MSa/s 2 MB memory/ch. 200 MSa/s 2 MB memory/ch
54622A Portable DSO Agilent 54600 Scopes (54621A/D, 54622A/D, 54624A) Frequently-Asked Questions (FAQs): What is the memory depth? The Agilent 54600 series uses the typical memory depth of. In some cases,
More informationFluke /
Fluke 190-104/190-204 ScopeMeter 190 Series II Service Manual PN 4822 872 05405 March 2011 2011 Fluke Corporation, All rights reserved. Printed in the Netherlands All product names are trademarks of their
More informationUser Manual. GPS-1000B+ series. Digital Oscilloscope V 1.1
User Manual GPS-1000B+ series Digital Oscilloscope V 1.1 Brief Introduction Characteristic: The volume of the oscilloscope is cabinet and it is portable 7 Color TFT LCD display 2 channels, Bandwidth:
More informationQRF5000 MDU ENCODER. Data Sheet
Radiant Communications Corporation 5001 Hadley Road South Plainfield NJ 07080 Tel (908) 757-7444 Fax (908) 757-8666 WWW.RCCFIBER.COM QRF5000 MDU ENCODER Data Sheet Version 1.1 1 Caution Verify proper grounding
More informationAnalog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube
TS-81000 DC 1 GHz, 4 CH, 15 traces TS-80600 DC 600 MHz, 4 CH, 15 traces There is the world, only Analog can capture it! State of the art Analog Oscilloscope As technology advanced rapidly, it is getting
More informationDigital Oscilloscope Waveform Generator DC Power Supply Digital Multimeter Spectrum Analyzer Handheld Oscilloscope Probes & Accessories
Digital Oscilloscope Waveform Generator DC Power Supply Digital Multimeter Spectrum Analyzer Handheld Oscilloscope Probes & Accessories SIGLENT TECHNOLOGIES 产品手册 PRODUCT CATALOG SIGLENT TECHNOLOGIES CO.,
More informationOSCILLOSCOPE AND DIGITAL MULTIMETER
Exp. No #0 OSCILLOSCOPE AND DIGITAL MULTIMETER Date: OBJECTIVE The purpose of the experiment is to understand the operation of cathode ray oscilloscope (CRO) and to become familiar with its usage. Also
More informationPC Oscilloscope Spectrum Analyzer Logic Analyzer
PC Oscilloscope Spectrum Analyzer Logic Analyzer DSO-50x12 Series User s Manual Revision I http://www.clock-link.com.tw Accessories Contents... 2 System Requirements... 2 Installing Hardware... 2 Installing
More informationIntroduction to the oscilloscope and digital data acquisition
Introduction to the oscilloscope and digital data acquisition Eric D. Black California Institute of Technology v1.1 There are a certain number of essential tools that are so widely used that every aspiring
More informationUser Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03
General Safety Summary General Safety Summary User Manual Digital Storage Oscilloscopes Models 2534, 2540 & 2542 Review the following safety precautions to avoid injury and prevent damage to this product
More informationTwo Channel PC Oscilloscopes with Arbitrary Waveform Generator OMSP-2000 Series
Two Channel PC Oscilloscopes with Arbitrary Waveform Generator OMSP-2000 Series U 10 to 25 MHz Bandwidths U Up to 200 MS/s Sampling Rate U Advanced Digital Triggers U Persistence Display Modes U Mask Limit
More informationAdvanced Test Equipment Rentals ATEC (2832)
E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar
More informationPicoScope 6 Training Manual
PicoScope 6 Training Manual DO226 PicoScope 6 Training Manual r2.docx Copyright 2014 Pico Technology CONTENTS 1 Quick guide to PicoScope 6... 1 1.1 The PicoScope way... 1 1.2 Signal view... 2 1.3 Timebase...
More informationWhat is oscilloscope? What an oscilloscope looks like. Oscilloscopes, accessories, applications Ján Šaliga
Oscilloscopes, accessories, applications Ján Šaliga 2017 What is oscilloscope? The main purpose of an oscilloscope is to give an accurate visual representation of electric signals. By viewing signals displayed
More informationUser Manual SDS1000CML+/SDS1000DL+ Digital Oscilloscope UM0101A-E01A SIGLENT TECHNOLOGIES CO,.LTD
User Manual SDS1000CML+/SDS1000DL+ Digital Oscilloscope UM0101A-E01A SIGLENT TECHNOLOGIES CO,.LTD Declaration Copyright by SIGLENT TECHNOLOGIES CO,.LTD. All rights reserved. Contents in this Manual are
More informationDAC Express Release 3.4 (VT9801B)
DAC Express Release 3.4 (VT9801B) DAC Express 3.4 Highlights n Display Wizard for fast test setups n 48-channel high performance remote strain measurement unit (EX1629) n Combine multi-channel analog,
More information