QUAD THERMOCOUPLE INPUT

Size: px
Start display at page:

Download "QUAD THERMOCOUPLE INPUT"

Transcription

1 QUAD THERMOCOUPLE INPUT Fits Tiger 320 Series On-board Digital Signal Processor. Choice of type J or K thermocouples. 0Hz Averaged output. Terminal Reference Junction. On-board Reference Junction Sensor. 8-pin Input Connector. Quad J or K Thermocouple. Interface to Tiger Meter. Crystal Controlled Line Frequency Rejection. 50 / 60Hz line frequency rejection. State-of-the-art Electromagnetic Noise Suppression Circuitry. Ensures signal integrity even in harsh EMC environments. Multiple inputs processed with powerful signal conditioning. Ideal for multi-temperature control systems, IST3 and IST4 monitor up to four individual thermocouple sensors at 0 Hz averaged output rate. A choice of industry J or K type thermocouples with an on-board temperature sensor for reference junction compensation provide a versatile interface for temperature measurement tasks. Input Module Order Code Suffix IST3 (50 Hz Rejection) IST4 (60 Hz Rejection) Input Channels Thermocouple Type Input Sensitivity Zero Drift Span Drift Non-linearity Input Noise Signal Processing Rate Reference Junction Hardware Module Specifications Four independent channels, zero -talk and 6-bit resolution. Industry standard J or K type (software selectable) µv / count maximum. ±40 nv / C typical. ±5 ppm / C full scale maximum. ±0.003% 5of full scale maximum. 60 nv p-p typical. 0 Hz averaged output rate on all channels. On-board solid state sensor referenced thermal connection to terminal block socket. Resolution better that 0. C. INPUTS Output Rate Sensor Selection Line Frequency Rejection Broken Thermocouple Software Module Specifications Fixed 0 Hz averaged per channel. Choice of J or K, software selectable. 50/60 Hz, software selectable. [OVER] on display indicates broken thermocouple. Software senses a broken thermocouple and causes the display to flash [OVER]. Note, only seen if that display is the current display. Otherwise, it can be checked through the view mode. TEMPERATURE IST3-4 Data Sheet (NZ362) Texmate, Inc. Tel. (760) Page

2 Connector Pinouts J Type: (TC+) Iron (TC ) Copper-nickel. Commonly used in the plastic moulding industry. Good in dry and reducing atmospheres. K Type: (TC+)Nickel-chromium (TC ) Nickel-aluminum. Most commonly used thermocouple with wide temperature range. Good in oxidizing atmospheres. TC TC2 TC3 TC4 TC + TC TC2 + TC2 TC3 + TC3 TC4 + TC4 PIN PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 38 Figure IST3/IST4 Quad Thermocouple Smart Input Module Smart Setup Registers The Tiger controller uses three smart setup registers to configure all smar t input modules. Line frequency rejection (50 / 60 Hz) and ther mocouple type are configured in smart register (SMT). See Figure 2. Thermocouple signals, TC, TC2, TC3, and TC4, are then individually softw are selected for the four input channels. Either signal can be selected f or CH via Code 2, CH2 via Code 4, CH3 via Code 5, and CH4 via Code 6. Note: Once selected, the thermocouple type is the same f or all four channels. Note: The same thermocouple signal can be selected f or two or more channels. Input Signal (TC) Input Signal 2 (TC2) Input Signal 3 (TC3) Input Signal 4 (TC4) CODE 2 SMART REGISTER SETUP OUTPUT REGISTER MAP SMT allo ws y ou to select either 50 or 60 Hz line frequency and select the thermocouple type f or all f our inputs: J or K. Enter Code 2. Select smart register setup [77]. This allows you to enter smart register setup and configure settings f or input signals, 2, 3, 4. SMART REGISTER 2 SETUP Not required. The output register map allows you to select an y of the four thermocouple inputs (TC, TC2, TC3, TC4) for any of the controller channels (CH, CH2, CH3, CH4). TC TC2 TC3 TC4 CH CH2 CH3 CH4 SMART REGISTER 3 SETUP Not required. Figure 2 IST3/IST4 Smar t Setup Registers Operational Flow Diagram TC TC2 TC3 TC4 PIN PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 Quad Input Analog to Digital Convertor 6-bit Resolution Microcontroller I 2 C Bus Tiger Interface Reference junction sensor thermally bonded to the connector block. Reference Junction Sensor Figure 3 IST3/IST4 Quad Thermocouple Functional Schematic Diagram Page 2 Texmate, Inc. Tel. (760) IST3-4 Data Sheet (NZ362)

3 Standard Setup Quick Start Guide This section describes the procedures to enter the controller s code structure and configure the input module for the following standard settings: 60 Hz Line Frequency (suitable for areas operating on 60 Hz power supplies). J Type Thermocouple. Thermocouple TC selected for channel (CH). All other configuration settings are described in the following pages. Operational Display From Step 5 Step Enter the Brightness Mode Step 6 Return to Code 2 and select the thermocouple for CH Example Step 2 Pass the Brightness Mode and enter Code 2 3 Step 7 Set Code 2 to [70]: st Digit = not relevant 2nd Digit = 7 Selects Smart Input Module 3rd Digit = 0 Selects Average TC (0 Hz) from the output register map Step 3 Set Code 2 to [77]: st Digit = not relevant 2nd Digit = 7 Selects Smart Input Module 3rd Digit = 7 Selects Smart Input Module Register Code Setup Step 8 Save settings and return to Code 2 Example Step 4 Enter the Smart Register (SMt) Setup Mode Step 5 Set SMt to [00]: st Digit = Selects 60 Hz noise rejection 2nd Digit = 0 Not relevant 3rd Digit = 0 Selects J type thermocouple To Step 6 Step 9 Exit Code 2 and return to the operational display Operational Display Programming Tip The f ollowing procedure uses a DI-50 displa y. The readings shown may differ for other display versions. IST3-4 Data Sheet (NZ362) Texmate, Inc. Tel. (760) Page 3

4 Programming Procedures The f ollowing prog ramming procedures co ver all the steps required to configure smar t input module IST3/IST4. Steps to 5 describe how to select the line frequency and the thermocouple type through smart register (SMT). Steps 7 to 2 describe how to select a specific ther mocouple from the output registers f or channels, 2, 3, or 4 as required. the P and buttons at the same to enter the main programming mode. 2 the P button three s to enter Code 2. Set Code 2 to [77]. This setting enters the smart register code setup menu. TIGER PROCESSING RATE 0 0 Hz 0 Hz 2 00 Hz 3 00 Hz Note: The output registers in the 3rd digit are specific to the Quad Thermocouple input module. These registers vary for each different smart input module. SECOND DIGIT MEASUREMENT TASK 0 Voltage, Current TC (3rd digit selects type of TC) 2 RTD 3-wire (3rd digit selects type of RTD) 3 RTD 2- or 4-wire (3rd digit selects type of RTD) 4 Frequency 5 Period 6 Counter 7 Smart Input Module THIRD DIGIT OUTPUT REGISTER MAP 0 Averaged TC (0 Hz) Averaged TC2 (0 Hz) 2 Averaged TC3 (0 Hz) 3 Averaged TC4 (0 Hz) 7 Smart input module register code setup 3 the P button. This men u provides settings unique to smart register of input module IST3/4. FREQUENCY SELECT 0-60 Hz rejection Hz rejection SECOND DIGIT NOT USED THIRD DIGIT THERMOCOUPLE TYPE 0 J type K type Using the buttons, select either 50 or 60 Hz line frequency rejection in the st digit and the thermocouple type in the 3rd digit. 2nd digit settings are not relevant and should be left at z ero (0). Note: 0 Hz is the average output for all four thermocouple inputs. Operational Temperature Range J Type Thermocouple K Type Thermocouple 0 C to 700 C 0 C to 00 C Approximate continuous working temperature range of measur ing junction. Not related to wire diameters and conducted insulation. Refer IEC 584.2, 982 (BS EN , 993) Inter nal Standards for Thermocouple Characteristics. 5 6 the P button. The display returns to [Cod_2] [77]. Using the button, reset the 3rd digit to z ero [70] to leave the smart register menu. Note: Leaving the 3rd digit as 7 means the display constantly cycles between [Cod_2] and [SMt]. 7 the P and buttons at the same to retur n to the operational display. Select a Channel Select a thermocouple output from the output register map of the required c hannel Channel 8 the P and buttons at the same again to re-enter the main prog ramming mode, then press the P button three s to enter Code 2. Page 4 Texmate, Inc. Tel. (760) IST3-4 Data Sheet (NZ362)

5 9 Set Code 2 to [7]. Select the required processing rate for CH in the st digit and the required register map settings in the 3rd digit. 2nd digit settings are not relevant and should be left at z ero (0). CH TIGER PROCESSING RATE 0 0 Hz 0 Hz 2 00 Hz 3 00 Hz Note: The output register map is different for each smart input module type. THIRD DIGIT OUTPUT REGISTER MAP 0 Averaged TC (0 Hz) Averaged TC2 (0 Hz) 2 Averaged TC3 (0 Hz) 3 Averaged TC4 (0 Hz) 7 Smart input module register code setup Channel 2 0 Set Code 4 to [00]. Select the required register map settings f or CH2 in the 2nd digit. CH2 MEASUREMENT TASK 0 Voltage, Current F VOLTAGE & CURRENT 0 Channel 2 Disabled Direct (no post processing) 2 Square Root of Channel 2 3 Inverse of Channel 2 4 Output Register (smart module)* 5 Output Register 2 (smart module)* 6 Output Register 3 (smart module)* 7 Output Register 4 (smart module)* SECOND DIGIT *Note: The logic f or CH2 is not the same as CH, CH3, or CH4. The st and 3rd digits must both be set to 0.Selecting 040 to 070 in the 2nd digit of Code 4 directly selects one of the f ollowing settings in the output register map (3rd digit): 2nd Digit 4 selects 5 selects 6 selects 7 selects Output Register Map 0 Averaged TC (0 Hz) Averaged TC2 (0 Hz) 2 Averaged TC3 (0 Hz) 3 Averaged TC4 (0 Hz) Channel 3 Enter Code 5 and select the required register map settings f or CH3 in the 3rd digit. CH3 Channel 4 CH3 POST PROCESSING 0 Direct Display of Input (no processing) Square Root of Channel 3 2 Inverse of Channel 3 3 Meters with 4 kb memory NO Linearization Meters with 32 kb memory 32-point Linear ization of CH3 using Table 3 Note: All linear ization tab les are set up in the Calibration Mode [24]. THIRD DIGIT OUTPUT REGISTER MAP 0 Averaged TC (0 Hz) Averaged TC2 (0 Hz) 2 Averaged TC3 (0 Hz) 3 Averaged TC4 (0 Hz) 7 Smart input module register code setup Note: The output register map is different for each smart input module type. Enter Code 6 and select the required register map settings f or CH4 in the 3rd digit. 2 CH4 the P button to save the settings. the P and buttons at the same to return to the operational display. CH4 POST PROCESSING 0 Direct Display of Input (no processing) Square Root of Channel 4 2 Inverse of Channel 4 3 Meters with 4 kb memory NO Linearization Meters with 32 kb memory 32-point Linear ization of CH4 using Table 4 Note: All linear ization tab les are set up in the Calibration Mode [24]. IST3-4 Data Sheet (NZ362) Texmate, Inc. Tel. (760) Page 5

6 Calibration As the calibration procedure requires a calibr ation source that can output stab le µv signals, calibration of the four channels is normally done in the factory prior to shipping. Calibrating 4 Channels for K Type Thermocouple If user calibration is required, the f ollowing procedure should be f ollowed. It is assumed that the user has a thermocouple calibration source available. When the controller is switched on, allow a few minutes warmup to let the reference junction stabilize to the connector ter minal block temperature. Setup Smart Register (SMT) See Page 4 and carry out Steps to 7 to select the required line frequency and thermocouple type. 2 Connect to the Calibrated Source Connect a standard K type ther mocouple plug to the calibration source. 3 Connect to the Input Module Connect the standard K type ther mocouple cable to the rele vant pins on the input module of the thermocouple input to be calibrated. IST3/IST4 Terminal Block TC + TC+ PIN Thermocouple Calibration Source K Type Thermocouple Plug K Type Thermocouple Wire TC TC2+ TC2 TC3+ PIN 2 PIN 3 PIN 4 PIN 5 TC3 PIN 6 TC4+ PIN 7 TC4 PIN 8 4 Set the Low Setting a) Set the calibration source to 0 C. b) Enter [CAL] [] and set to [ZEro] setting. 5 Set the High Setting a) Set the calibration source to 00 C. b) Set to [SPAn] setting to Repeat Steps Repeat Steps 2 to 4 for all required thermocouples and channels. See 2-point Calibration Mode Example on Page 7 for a step-by-step calibration procedure. Note: One thermocouple can be assigned to one or more c hannels (e.g. TC assigned to CH to CH4), but each channel can accept only one thermocouple input. Page 6 Texmate, Inc. Tel. (760) IST3-4 Data Sheet (NZ362)

7 STAR ART T HERE 2-point Calibration Mode Example Operational Display From Step 6 Step Enter the brightness mode HIGH Step 7 Signal 7.. Adjust display to desired reading for span input Step 2 Pass the brightness mode and the enter calibration mode 7.2. Apply the HIGH input signal Step 8 Save zero and span settings and re-enter calibration mode Example Step 3 Set calibration mode to []: st Digit = Selects calibration procedures 2nd Digit = Selects 2-point calibration 3rd Digit = Selects CH for calibration Step 4 Enter calibration mode [] for 2-point calibration of CH [] for CH [2] for CH2 [3] for CH3 [4] for CH4 Step 9 Select the no function calibration mode [000] Step 0 Save calibration mode [000] setting and enter Code Step Adjust display to desired reading for zero input 5.2. Apply the LOW input signal Step 6 Set reading for zero load into meter and enter span mode LOW Signal Example To Step 7 Step Exit Code and return to the operational display Operational Display IST3-4 Data Sheet (NZ362) Texmate, Inc. Tel. (760) Page 7

8 Customer Configuration Settings: st Digit 2nd Digit 3rd Digit CH st Digit 2nd Digit 3rd Digit CH3 st Digit 2nd Digit 3rd Digit 7 CH2 st Digit 2nd Digit 3rd Digit 0 0 CH4 st Digit 2nd Digit 3rd Digit 7 WARRANTY Texmate warrants that its products are free from def ects in mater ial and w orkmanship under normal use and ser vice for a per iod of one y ear from date of shipment. Texmate s obligations under this warranty are limited to replacement or repair, at its option, at its factory, of any of the products which shall, within the applicable period after shipment, be returned to Texmate s facility, transportation charges pre-paid, and which are, after e xamination, disclosed to the satisfaction of Texmate to be thus def ective. The warranty shall not apply to an y equipment which shall have been repaired or altered, except by Texmate, or which shall have been subjected to misuse, negligence, or accident. In no case shall Texmate s liability e xceed the or iginal purchase price. The aforementioned provisions do not e xtend the or iginal warranty period of any product which has been either repaired or replaced b y Texmate. USER S RESPONSIBILITY We are pleased to offer suggestions on the use of our v arious products either by way of printed matter or through direct contact with our sales/application engineering staff. However, since we ha ve no control o ver the use of our products once the y are shipped, NO WARRANTY WHETHER OF MERCHANTABILITY, FITNESS F PURPOSE, O THERWISE is made beyond the repair, replacement, or refund of purchase pr ice at the sole discretion of Texmate. Users shall deter mine the suitability of the product f or the intended application bef ore using, and the users assume all risk and liability whatsoever in connection therewith, regardless of any of our suggestions or statements as to application or constr uction. In no event shall Texmate s liability, in law or otherwise, be in excess of the purchase pr ice of the product. Texmate cannot assume responsibility for any circuitry described. No circuit patent or software licenses are implied. Texmate reserves the right to change circuitry, operating software, specifications, and prices without notice at any. For product details visit Kellogg Ave. Carlsbad, CA Tel: USA That s orders@texmate.com Web: Page 8 Texmate, Inc. Tel. (760) IST3-4 Data Sheet (NZ362)

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function. Triple RTD SMART INPUT MODULE State-of-the-art Electromagnetic Noise Suppression Circuitry. Ensures signal integrity even in harsh EMC environments. On-board Digital Signal Processor. Linearization RTDs

More information

16-BIT LOAD CELL/DUAL STATUS INPUT

16-BIT LOAD CELL/DUAL STATUS INPUT 16-BIT LOAD CELL/DUAL STATUS INPUT On-board Excitation. +5VDC, (120mA). State-of-the-art Electromagnetic Noise Suppression Circuitry. Ensures signal integrity even in harsh EMC environments. Optional Excitation

More information

Fits the Leopard Family FREQ./RPM INPUT MODULE WITH 24 V EXC.

Fits the Leopard Family FREQ./RPM INPUT MODULE WITH 24 V EXC. Fits the Leopard Family FREQ./RM INUT MODULE WITH 24 V EXC. Low-pass Filter., 2 khz,. Switching Comparator. revents false triggering. Input Connector. Freq. Input. 24 V Excitation. Sensor. Mag, Namur,

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 PRODUCT NAME: 378 TEMPERATURE CONTROLLER - 1 - The model 378 is a high performance

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016 OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016 1-800-TIP-TEMP Tel. (609) 239-1900 Fax (609) 239-1911 www.tiptemp.com GENERAL

More information

PROGRAMMING CODE SHEET

PROGRAMMING CODE SHEET Tiger Programming Code Sheet Tiger PROGRAMMING CODE SHEET Contents Initial Setup Procedures.............................2 Tiger Code Logic Diagram.................4 CALIBRATION MODE..............................5

More information

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805) FOTS100 User Manual BIOPAC Systems, Inc. 42 Aero Camino, Goleta, CA 93117 Tel (805) 685-0066, Fax (805) 685-0067 WWW.BIOPAC.COM 1 WARRANTY All products manufactured by Opsens inc. are warranted to be free

More information

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT FN: 341MAN1.DOC AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT DESCRIPTION AE Series Process Indicators are available with 1", 2.3", 4", 8", or 12" high digits,

More information

LED Series Sealed Backlights

LED Series Sealed Backlights For use with any Vision system Rugged, waterproof housing, rated IEC IP67 Mounts directly from the back or surface mount using available brackets Smooth exterior for easy cleaning Diffused backlights for

More information

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0 by USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.0 www.aeroforcetech.com Made in the USA! WARNING Vehicle operator should focus primary attention to the road while using the Interceptor. The information

More information

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630) Vorne Industries 87/719 Analog Input Module User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Introduction... 1.1 Accessing Wiring Connections

More information

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide 1 1 CH1 CH2 1 1 CH4 CH 1 CH3 6s Master /Fade CH6 1 SC1 6s SC4 SC2 SC SC3 SC6 Off/Pro AL Fade 6 Pro User guide CONTENTS INTRODUCTION...2 Welcome 2 Safety 2 Supplied items 3 INSTALLATION...4 Mounting 4

More information

6-digit, 0.56 (14.2 mm) Alphanumeric Display. 1/8 DIN Case 3-button Front Panel Operation. Intuitive Scrolling Text Configuration Menus

6-digit, 0.56 (14.2 mm) Alphanumeric Display. 1/8 DIN Case 3-button Front Panel Operation. Intuitive Scrolling Text Configuration Menus TIGER FAMILY Introduction The LDT-200 Series are accurate, high performance, programmable dual channel controllers that deliver precise measurement and control for applications using LDT (Linear ariable

More information

Model 6010 Four Channel 20-Bit Audio ADC Data Pack

Model 6010 Four Channel 20-Bit Audio ADC Data Pack Model 6010 Four Channel 20-Bit Audio ADC Data Pack Revision 3.1 SW v1.0.0 This data pack provides detailed installation, configuration and operation information for the Model 6010 Four Channel 20-bit Audio

More information

Thermocouple and RTD Modules for Compact FieldPoint

Thermocouple and RTD Modules for Compact FieldPoint Thermocouple and Modules for Compact FieldPoint NI cfp-tc-120, NI cfp-tc-125, NI cfp--122, NI cfp--124 8 temperature inputs Thermocouple or millivolt 2-, 3-, or 4-wire Built-in signal conditioning between

More information

CN12 Technical Reference Guide. CN12 NTSC/PAL Camera. Technical Reference Guide PCB Rev

CN12 Technical Reference Guide. CN12 NTSC/PAL Camera. Technical Reference Guide PCB Rev CN12 NTSC/PAL Camera Technical Reference Guide PCB Rev 1.0 www.soc-robotics.com Copyright 2010. SOC Robotics, Inc. 1 Manual Rev 0.90 Warranty Statement SOC Robotics warrants that the Product delivered

More information

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1

USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1 by USER MANUAL FOR THE ANALOGIC GAUGE FIRMWARE VERSION 1.1 www.aeroforcetech.com Made in the USA! WARNING Vehicle operator should focus primary attention to the road while using the Interceptor. The information

More information

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL UM-TS02 -E026 PROGRAMMABLE CONTROLLER PROSEC T2-series ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL TOSHIBA CORPORATION Important Information Misuse of this equipment can result in property damage

More information

Owner's Manual LIGHTING CONTROL CONSOLE TEATRONICS LIGHTING CONTROLS, INC. PROCON II Los Osos Valley Rd., Ste. G Los Osos, CA 93402

Owner's Manual LIGHTING CONTROL CONSOLE TEATRONICS LIGHTING CONTROLS, INC. PROCON II Los Osos Valley Rd., Ste. G Los Osos, CA 93402 Owner's Manual PROCON II LIGHTING CONTROL CONSOLE TEATRONICS LIGHTING CONTROLS, INC. 1236 Los Osos Valley Rd., Ste. G Los Osos, CA 93402 Phone: (805) 528-6900 PROCON II FAX: (805) 528-9345 12/01/94 Page//

More information

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual REMOTE I/O R30 SERIES PC CONFIGURATOR SOFTWARE Model: R30CFG Ver. 1.13 Users Manual 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 http://www.m-system.co.jp/

More information

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Product data sheet Characteristics STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Main Range of product Product or component type Kit composition Analogue input type Analogue input number

More information

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE 9350-7676-000 Rev B, 5/2001 PROPRIETARY NOTICE The RTS product information and design disclosed herein were originated by and are the property of

More information

Transmitter Interface Program

Transmitter Interface Program Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following

More information

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated) INSTRUCTION MANUAL THERMOCOUPLE & INPUT MODULE (8 points; isolated) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

35058-TE. PLJ-6LED-A LED Frequency Display Module Manual

35058-TE. PLJ-6LED-A LED Frequency Display Module Manual 35058-TE 6-digit LED Frequency Counter Module GREEN DISPLAY LED Frequency Display Module Manual Three Swords Studio Light Rongsheng 2013, March Guangxi Nanning Longan Information including Links and Code

More information

instruction manual video scan reverser models NVCN422CS & NVCN422C

instruction manual video scan reverser models NVCN422CS & NVCN422C instruction manual video scan reverser models NVCN422CS & NVCN422C s/n boulder, colorado WARNING This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance

More information

AEXX-200F SERIES 4-DIGIT LINE FREQUENCY MONITORS

AEXX-200F SERIES 4-DIGIT LINE FREQUENCY MONITORS FN:200FMAN1.DOC AEXX-200F SERIES 4-DIGIT LINE FREQUENCY MONITORS DESCRIPTION AEXX-200F Series Line Frequency Monitors are precision large digital displays that measure power line frequency with a 0.01

More information

STD-525T PRECISION TIMER

STD-525T PRECISION TIMER FN:STD525TM1.DOC STD-525T PRECISION TIMER DESCRIPTION The STD-525T Precision Timer measures and displays accurate elapsed time in minutes, seconds, tenths of seconds, and hundredths of seconds (MM.SS.TH)

More information

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013 SR - 516D DESK TOP DMX REMOTE STATION Version: 1.10 Date: 05/16/2013 Page 2 of 10 TABLE OF CONTENTS DESCRIPTION 3 POWER REQUIREMENTS 3 INSTALLATION 3 CONNECTIONS 3 POWER CONNECTIONS 3 DMX CONNECTIONS 3

More information

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011 RD - 122 RACK MOUNT DIMMER OWNERS MANUAL VERSION 1.3 03/09/2011 Page 2 of 14 TABLE OF CONTENTS UNIT DESCRIPTION AND FUNCTIONS 3 POWER REQUIREMENTS 3 INSTALLATION 3 PLACEMENT 3 POWER CONNECTIONS 3 OUTPUT

More information

MaxView Cinema Kit Quick Install Guide

MaxView Cinema Kit Quick Install Guide SYSTEM SETUP The MaxView will work at any of the following display settings: INSTALLATION MaxView Cinema Kit Quick Install Guide Step 1 - Turn off your computer. Disconnect your monitor s VGA cable from

More information

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load

More information

32 Channel CPCI Board User Manual

32 Channel CPCI Board User Manual 0 Sections Page 1.0 Introduction 1 2.0 Unpacking and Inspection 1 3.0 Hardware Configuration 1 4.0 Board Installation 5 5.0 I/O Connections and the Front Panel 5 5.1 Front Panel Layout 5 5.2 Input and

More information

Noise Detector ND-1 Operating Manual

Noise Detector ND-1 Operating Manual Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation

More information

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999

More information

AM-4 Audio Monitor. Videoquip Research Limited 595 Middlefield Road, Unit #4 Scarborough, Ontario, Canada. MIV 3S2

AM-4 Audio Monitor. Videoquip Research Limited 595 Middlefield Road, Unit #4 Scarborough, Ontario, Canada. MIV 3S2 AM-4 Audio Monitor Videoquip Research Limited 595 Middlefield Road, Unit #4 Scarborough, Ontario, Canada. MIV 3S2 (416) 293-1042 1-888-293-1071 www.videoquip.com AM-4 4 channel Analog, AES3 Digital, SDI

More information

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Warner Photoscanner MCS-500 Series LED Photoelectric Control Warner Photoscanner MCS-500 Series LED Photoelectric Control P-241-100 819-0504 Installation & Operating Instructions Contents Description.............................. 2 Specifications.........................

More information

Linear Array with Intensity Adjustment

Linear Array with Intensity Adjustment Datasheet High-Power Lighting with Intensity Adjustment for use with Vision Systems For complete technical information about this product, including dimensions, accessories, and specifications, see www.bannerengineering.com/lineararraylights.

More information

Low Voltage Multifunctional LED Controller / DMX Decoder. Specification

Low Voltage Multifunctional LED Controller / DMX Decoder. Specification Low Voltage Multifunctional LED Controller / DMX Decoder Specification High Power DMX Decoder & Driver Meets DMX 512/1990 Protocol LT-300 can drive up to 8A current on each channel Capable of driving many

More information

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE JY992D55901A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX-4AD-TC special

More information

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual TRIPLETT PairMaster Lan Cable Test Set Instruction Manual The PairMaster LAN CABLE TEST SET INSTRUCTION MANUAL IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS Before using the PairMaster, read all

More information

Warranty and Registration. Warranty: One Year. Registration: Please register your product at Port, or. or Windows.

Warranty and Registration. Warranty: One Year. Registration: Please register your product at   Port, or. or Windows. 7 7 Port, or or Windows Port Warranty and Registration Warranty: One Year Registration: Please register your product at www.aitech.com 2007 AITech International. All rights reserved. WEB CABLE PLUS PC-TO-TV

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200

More information

Instruction Guide. The TV Jockey Computer Monitor TV Tuner with Remote COMP2VGATVGB. The Professionals Source For Hard-to-Find Computer Parts

Instruction Guide. The TV Jockey Computer Monitor TV Tuner with Remote COMP2VGATVGB. The Professionals Source For Hard-to-Find Computer Parts VIDEO ADAPTER The TV Jockey Computer Monitor TV Tuner with Remote COMP2VGATVGB Instruction Guide * Actual product may vary from photo The Professionals Source For Hard-to-Find Computer Parts FCC COMPLIANCE

More information

VT VGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide

VT VGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide VT1040 10.4 VGA TFT NEMA 4/12 Flat Panel Monitor User s Guide 301040(A) (was document no. 920A0001 version 1.1), revised 01/98 Viewtronix Viewtronix reserves the right to make changes in specifications

More information

DVDO VS4 HDMI Switch. User s Guide How to install, set up, and use your new DVDO product

DVDO VS4 HDMI Switch. User s Guide How to install, set up, and use your new DVDO product DVDO VS4 HDMI Switch User s Guide How to install, set up, and use your new DVDO product TABLE OF CONTENTS Table of Contents... 1 Introduction... 1 Installation and Set-Up... 2 Remote Control Operation...

More information

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN Main features Ranges: from: 0...1000 to 0...5000 bar Output signal 4...20mA 2 wires / 0,1...5,1Vdc / 0.1...10.1Vdc / 0...5Vdc / 0...10Vdc

More information

instruction manual video color synthesizer Model 606 & 606S

instruction manual video color synthesizer Model 606 & 606S instruction manual video color synthesizer Model 606 & 606S s/n colorado video, inc boulder, colorado january 2006 WARNING This equipment generates, uses and can radiate radio frequency energy and if not

More information

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE JY992D65501A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4AD-TC

More information

Reference 150 LINEAR

Reference 150 LINEAR Reference 150 LINEAR USER GUIDE Congratulations on your new CONSONANCE! Our products are based on a simple philosophy: The component shall reproduce the original musical sound, purely and naturally. The

More information

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2 OPERATING MANUAL DMX / DSI / DALI Dekoder 3004B-H Mk2 (C) SOUNDLIGHT 1996-2004 * ALL RIGHTS RESERVED * NO PART OF THIS MANUAL MAY BE REPRODUCED, DUPLICATED OR USED COMMERCIALLY WITHOUT THE PRIOR WRITTEN

More information

Operating Manual for Clock / Auxiliary Displays for VHX systems

Operating Manual for Clock / Auxiliary Displays for VHX systems Operating Manual for Clock / Auxiliary Displays for VHX systems The VHX auxiliary display module is designed to work with a Dakota Digital VHX system and will not function properly on its own. With this

More information

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual. Manual Title: 744 Users Supplement Issue: 6 Part Number: 691287 Issue Date: 4/06 Print Date: September 1998 Page Count: 8 Revision/Date: 1, 2/99 This supplement contains information necessary to ensure

More information

DD624CS Hi-Def Video Circle & Cross Hair Overlay Generator. Users Manual. Colorado Video

DD624CS Hi-Def Video Circle & Cross Hair Overlay Generator. Users Manual. Colorado Video DD624CS Hi-Def Video Circle & Cross Hair Overlay Generator Users Manual Colorado Video WARNING This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance

More information

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel OWNERS MANUAL Revision 1.8 09/01/2002 OWNERS MANUAL Page 2 of 12 AR-1202 UNIT DESCRIPTION The AR-1202 consists of a processor and 12 dimmer channels of 2.4KW each. Each dimmer channel is protected by a

More information

Revision 1.2d

Revision 1.2d Specifications subject to change without notice 0 of 16 Universal Encoder Checker Universal Encoder Checker...1 Description...2 Components...2 Encoder Checker and Adapter Connections...2 Warning: High

More information

Operation Manual. 3G/HD/SD-SDI-TO-HSDA HSDA-TO-3G/HD/SD-SDI Broadcast Convertor

Operation Manual. 3G/HD/SD-SDI-TO-HSDA HSDA-TO-3G/HD/SD-SDI Broadcast Convertor 3G/HD/SDSDITOHSDA HSDATO3G/HD/SDSDI Broadcast Convertor Operation Manual KENSENCE INTERNATIONAL PTE LTD Version number V3.0.0 September.203.Product Introduction...4 2.Main Functions...5 3.Specification...6

More information

TRIPLETT HDMI2. High Definition Cable Tester. Instruction Manual

TRIPLETT HDMI2. High Definition Cable Tester. Instruction Manual TRIPLETT WireMaster HDMI2 High Definition Cable Tester Instruction Manual 84-893 10 / 2010 WireMaster HDMI FEATURES Lightweight, Rugged, Simple to use Test fragile, easily damaged HDMI Patch Cables and

More information

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Website:   Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide Website: www.flexispot.com Tel: -855-4-808 ADDRESS: 6475 Las Positas Rd. Livermore, CA 9455 Item No. E5B/E5S Installation Guide Specifications Step Column 3 Max. Weight Capacity 0 Ibs (00 kg) Speed 38mm/s

More information

Using DLP LightCrafter 4500 Triggers to Synchronize Cameras to Patterns

Using DLP LightCrafter 4500 Triggers to Synchronize Cameras to Patterns Application Report Using DLP LightCrafter 4500 Triggers to Synchronize Cameras to ABSTRACT This document describes how to use the DLP LightCrafter 4500 with the global trigger function of industrial USB

More information

DF-G3 Long Range Expert Dual Display Fiber Amplifier

DF-G3 Long Range Expert Dual Display Fiber Amplifier DF-G3 Long Range Expert Dual Display Fiber Amplifier Quick Start Guide Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies; single or dual independent output

More information

JENCO ELECTRONICS, LTD.

JENCO ELECTRONICS, LTD. OPERATION MANUAL JENCO MODEL 378 Indicating temp. controller JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISON INSTRUMENTS GENERAL INTRODUCTION The model 378 is a high performance industrial grade digital

More information

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17 Page 1 of 6 FEATURES AND SPECIFICATIONS LEDS: 18, 6W each (Warm White, Cool White, 2in1) Beam angle: 25º or 45 Control system: DMX512 + Stand Alone Modes DMX channels: 1/2/3/4/5 DMX connectors: 3 pin XLR

More information

PicoScope 3000 Series Automotive User guide

PicoScope 3000 Series Automotive User guide PicoScope 3000 Series Automotive User guide PS3000A044 v1.0 I PicoScope 3000 Series Automotive PC Oscilloscopes Table of Contents 1 Introduction...2...2 1 Overview...2 2 Minimum PC requirements...2 3 Installation

More information

instruction manual video mixer model 614gs & 614g

instruction manual video mixer model 614gs & 614g instruction manual video mixer model 614gs & 614g s/n COLORADO VIDEO, INC BOULDER, COLORADO February 2003 WARNING This equipment generates, uses and can radiate radio frequency energy and if not installed

More information

Metal Electrode Meter

Metal Electrode Meter Metal Electrode Meter INSTRUCTION MANUAL FOR Metal Electrode Meter MODEL 2900 Serial # Date PO Box 850 Carlsborg, WA 98324 U.S.A. 360-683-8300 800-426-1306 FAX: 360-683-3525 http://www.a-msystems.com Version

More information

WLC60 Heavy Duty LED Light - PWM Dimmable

WLC60 Heavy Duty LED Light - PWM Dimmable WLC60 Heavy Duty LED Light - PWM Dimmable Datasheet Banner's WLC60 Heavy Duty Lights are engineered to withstand harsh environments, making it the first choice for a machine lighting solution. A conservative

More information

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4 LANsmart Pro user manual Introduction LANsmart Pro is a hand-held, multifunction Cable Map Tester and Cable Length Meter. It has an integrated Analog and Digital Tone Generator, Port Finder, and Quick

More information

CARLO GAVAZZI Automation Components

CARLO GAVAZZI Automation Components CARLO GAVAZZI Automation Components UDM 35/40 Digital Panel Meter Programming Guide Index Description 2 Programming Fundamentals 3 Access to Programming Mode/Password Protection 4 Programming 5-18 Inputs

More information

SIL-2 8-Ch Analog Input Series Thermocouple, High Level, Low Level

SIL-2 8-Ch Analog Input Series Thermocouple, High Level, Low Level SIL-2 8-Ch Analog Input Series Thermocouple, High Level, Low Level 3107/3108/3109 PRODUCT HIGHLIGHTS 8 Isolated Channels for Safety and Critical Control Applications Configurable Redundancy Single, Dual,

More information

C-net WIND. User s Guide

C-net WIND. User s Guide C-net WIND User s Guide EMC Directive 89/336/EEC This product has been designed to be compliant with the above EMC Directive. Maximum performance and compliance with the EMC Directive can only be ensured

More information

PCI Express JPEG Frame Grabber Hardware Manual Model 817 Rev.E April 09

PCI Express JPEG Frame Grabber Hardware Manual Model 817 Rev.E April 09 PCI Express JPEG Frame Grabber Hardware Manual Model 817 Rev.E April 09 Table of Contents TABLE OF CONTENTS...2 LIMITED WARRANTY...3 SPECIAL HANDLING INSTRUCTIONS...4 INTRODUCTION...5 OPERATION...6 Video

More information

3M Sensored Termination (15 kv) QX-T15I-vi1-E

3M Sensored Termination (15 kv) QX-T15I-vi1-E 3M Sensored Termination () QX-T15I-vi1-E Data Sheet May 2016 Kit Contents: Each kit contains sufficient quantities of the following materials to make three single-phase terminations. 31" (REF) One piece

More information

Tutorial on Technical and Performance Benefits of AD719x Family

Tutorial on Technical and Performance Benefits of AD719x Family The World Leader in High Performance Signal Processing Solutions Tutorial on Technical and Performance Benefits of AD719x Family AD7190, AD7191, AD7192, AD7193, AD7194, AD7195 This slide set focuses on

More information

Flat-Bed Module Recorders

Flat-Bed Module Recorders Flat-Bed Module Recorders Model No. 08376-50 08376-55 08376-60 0115-0192 4/28/00 Table of Contents Introduction...3 Power Requirements...3 Chart Paper Installation...3 Pen Installation...5 Grounding...5

More information

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

Model 5250 Five Channel Digital to Analog Video Converter Data Pack Model 5250 Five Channel Digital to Analog Video Converter Data Pack E NSEMBLE D E S I G N S Revision 3.1 SW v2.0.1 This data pack provides detailed installation, configuration and operation information

More information

PT8420 Cable Actuated Sensor Industrial ma 0..20mA

PT8420 Cable Actuated Sensor Industrial ma 0..20mA PT8 Cable ctuated Sensor Industrial.. m..m bsolute Linear Position to 6 inches (5 mm) luminum or Stainless Steel Enclosure Options VLS Option to Prevent Free-Release Damage IP68 / NEM 6 Hazardous rea Certification

More information

TABLE OF CONTENTS. Instructions:

TABLE OF CONTENTS. Instructions: TABLE OF CONTENTS Instructions: 1 Overview 1 2 Main technical parameters 1 3 Display and keyboard 2 3.1 Display Window 2 3.2 Indicator 4 4. Operation 4 4.1 Power 4 4.2 Zero 4 Modified 4 4.3 Modified 4

More information

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual TC3004 50Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) MODEL: S/N: DATE: Notice! Although every effort has been made to insure that this manual is current and accurate as of date of publication,

More information

Model: HDCMP31. Installation Guide

Model: HDCMP31. Installation Guide Model: HDCMP31 Installation Guide 1 Contents Application Diagram... 3 Installation... 3 Smart Scan TM... 3 Configuring Smart Scan TM... 4 Description... 4 Features... 4 Remote Control Guide... 6 Warranty...

More information

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL www.prolight.co.uk TRANSCENSION 6-CHANNEL PACK (order code: BOTE40) USER MANUAL SAFETY WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this

More information

TC3005(LED/ELED/LASER) User's Manual

TC3005(LED/ELED/LASER) User's Manual 1. Description The gives users the ability to convert signals to format for data transmission (and vice-versa). These conversions can benefit users by extending transmission distances and/or enabling dissimilar

More information

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01 Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation

More information

ProVu PD6000 Process Meter

ProVu PD6000 Process Meter Congratulations on your purchase of the ProVu PD6000 process meter! This quick start guide will briefly describe some of the common setup procedures for this meter. This guide includes: Basic Wiring for

More information

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB September 2013 PACSystems* RX3i Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB Isolated +24 VDC Power Isolated Thermocouple

More information

INSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

INSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE 210 South Third Street North Wales, PA USA 19454 (T) 215-699-2060 (F) 215-699-2061 INSTRUCTION MANUAL FOR LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE i TO THE CUSTOMER Thank you for purchasing this

More information

Ezecal MK3 User Manual

Ezecal MK3 User Manual Ezecal MK3 User Manual FGH Controls Ltd Openshaw Way,Letchworth Herts. SG6 3ER Tel: +44 (0) 1462 686677 Fax: +44 (0) 1462 671860 Email: sales@fgh.co.uk www.fgh.co.uk EZECAL MK3 User Manual 1 EZECAL MK3

More information

Model: UHD41-ARC. Installation Guide

Model: UHD41-ARC. Installation Guide Model: UHD41-ARC Installation Guide 1 Safety Information: Electrical safety Use only the power supplies and the AC power cord that were included with your product. Use of other power supplies could damage

More information

Flarm LED indicator. Version 1.13

Flarm LED indicator. Version 1.13 Flarm LED indicator Version 1.13 LXNAV d.o.o. Kidričeva 24, 3000 Celje, Slovenia tel +386 592 33 400 fax +386 599 33 522 info@lxnav.com www.lxnav.com 1 Important Notices 3 1.1 Limited Warranty 3 2 Packing

More information

DP1 DYNAMIC PROCESSOR MODULE OPERATING INSTRUCTIONS

DP1 DYNAMIC PROCESSOR MODULE OPERATING INSTRUCTIONS DP1 DYNAMIC PROCESSOR MODULE OPERATING INSTRUCTIONS and trouble-shooting guide LECTROSONICS, INC. Rio Rancho, NM INTRODUCTION The DP1 Dynamic Processor Module provides complete dynamic control of signals

More information

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Slimline Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire: 4... 20 ma

More information

OPERATIONAL MANUAL EMZS CH Speaker Zone Selector. Version 1.6

OPERATIONAL MANUAL EMZS CH Speaker Zone Selector. Version 1.6 OPERATIONAL MANUAL EMZS-8012 12CH Speaker Zone Selector Version 1.6 1 Product Overview The EMZS-8012 is a 1U rack-mounting unit, provide 12 channel direct zone switching for single source public address

More information

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Dragonfly Quad. User Manual V1.4. Order code: EQLED101 Dragonfly Quad User Manual V1.4 Order code: EQLED101 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

TRIPLETT WireMaster HDMI

TRIPLETT WireMaster HDMI TRIPLETT WireMaster HDMI High Definition Cable Tester Instruction Manual 84-881 9/09 WireMaster HDMI FEATURES Lightweight, Rugged, Simple to use Test fragile, easily damaged HDMI Patch Cables and In-wall

More information

SignalTap Plus System Analyzer

SignalTap Plus System Analyzer SignalTap Plus System Analyzer June 2000, ver. 1 Data Sheet Features Simultaneous internal programmable logic device (PLD) and external (board-level) logic analysis 32-channel external logic analyzer 166

More information

SIWAREX FTA Weighing Module for High Accuracy Requirements Calibrating SIWAREX FTA with SIWATOOL FTA

SIWAREX FTA Weighing Module for High Accuracy Requirements Calibrating SIWAREX FTA with SIWATOOL FTA SIWAREX FTA Weighing Module for High Accuracy Requirements Calibrating SIWAREX FTA with SIWATOOL FTA Quick Guide For modules with order number 7MH4900-2AA01 Contents 1 2 3 4 5 6 Hardware-Requirements..

More information

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor Industrial Pressure Transmitter with i²c interface Stainless Steel Sensor Accuracy according to IEC 60770: standard: ± 0. % FSO option: ± 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Digital

More information

201AN DC VOLTMETER 201AN-AC VOLTMETER

201AN DC VOLTMETER 201AN-AC VOLTMETER 201AN DC VOLTMETER 201AN-AC VOLTMETER Operator s Manual http://www.newportus.com/manuals Additional products from Counters Frequency Meters PID Controllers Clock/Timers Printers Process Meters On/Off Controllers

More information

4X1 Gefen TV Switcher GTV-HDMI N. User Manual

4X1 Gefen TV Switcher GTV-HDMI N. User Manual 4X1 Gefen TV Switcher GTV-HDMI1.3-441N User Manual INTRODUCTION Congratulations on your purchase of the 4x1 GefenTV Switcher. Your complete satisfaction is very important to us. GefenTV GefenTV is a unique

More information