R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

Size: px
Start display at page:

Download "R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL"

Transcription

1 OPTEVA 868 THROUGH THE WALL ATM WITH 40mm ( 6") CEN III AND CEN IV SAFE L0 CALL (6") REQUIRED FOR WALLS EXCEEDING 0mm (2") CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE PLANNING AND SITE PREPARATION GUIDE TP A. 4 6 (4") 6") ( SAFE 024 6") 80 SAFE AND HINGES (4 4") 8 SAFE ( 6") ( 6") PAGE OF 6 26 (4 W ITH ILLUMINATED SIGNAGE PANEL 6") ( FASCIA 08 6") (2 (42 22 ( 8 W.O. (2") 8 FASCIA ( 4") PLAN VIEW 8FASCIA ( 4") 22 ( TOP OF TOUCH SCREEN 28 4") (0 0mm (2") MAXIMUM 26 OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL (4 W ITH ILLUMINATED SIGNAGE PANEL FASCIA 08 (42 NOTE: FOR VARIOUS FASCIA CONFIGURATIONS AND CONSUMER ACCESS DIMENSIONS SEE PAGE 6 OF 6 W.O. 0 6") 0mm (2") MAXIMUM 0 ( 6 (2 6") 2 ( ") (8 6") ( 6 6") (62 FILE NO. -60 REV. 4 6") (2 OPTIONAL CONSUMER BAR CODE SCANNER (SEE "CAUTION" LABEL) SEE SHEET 2 OF 6 SEE WALL OPENING DETAIL FOR RECOMMENDED CLEARANCE REQUIRED AROUND FASCIA. WALL OPENING NOTE : INSIDE FLOOR LEVEL MUST BE THE SAME AS OUTSIDE SIDEWALK LEVEL FOR OPTIMUM ACCESS. IF INSIDE FLOOR IS HIGHER OR LOWER THAN OUTSIDE, DIMENSION FOR LOCATING WALL OPENING WILL HAVE TO BE ADJUSTED ACCORDINGLY AND OPTIMUM ACCESS REQUIREMENTS WILL NOT BE MET. EXTERIOR ELEVATION 4 6") (2 6 6") (22 MAX. WALL HOLD SEE W ALL OPENING NOTE 0 (2") (2 6") 0 (20 8 ( 2") 46 ( 6") 024 SAFE ( 4") 6") VERTICAL SECTION 4

2 R 2 4 CONDUIT AND JUNCTION BOX REQUIREMENTS 2mm (") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO 02mm (4") SQ. X 4mm (2 DEEP JUNCTI0N BOX (ALL BY OWNER'S E.C.). DIEBOLD TO PROVIDE FLAT COVER WITH TAMPER SWITCH. WHEN "SECUROMATIC" AFTER HOUR DEPOSITORY IS TO BE CONNECTED TO ATM, OWNER'S E.C. TO RUN mm ( 4") METAL CONDUIT FROM 02mm (4") SQ. X 4mm (2 DP. JUNCTION BOX TO AFTER HOUR DEPOSITORY. OWNER'S E.C. TO RUN mm ( 4") LIQUID TIGHT FLEX METAL CONDUIT OR mm ( 4") RIGID CONDUIT FROM JUNCTION BOX TO CABLE CONNECTION PLATE. mm ( 4") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 02mm (4") SQ. X 4mm (2 DEEP JUNCTION BOX WITH RECEPTACLE WITHIN 220 ( OF SIDE CONNECTING PLATE. BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY (ALL BY OWNER'S E.C.) (SEE POWER REQUIREMENTS). OWNER'S E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC PLUG-IN CONNECTOR SUPPLIED WITH UNIT. POWER CORD LENGTH 2,84 (86") FROM SIDE OF UNIT. NOTE: JUNCTION BOXES MUST BE LOCATED WITHIN 220mm ( OF CONNECTING PLATE. (LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT). LOCATE IN AN EASILY ACCESSIBLE AREA. BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH EXPOSED CONDUIT FOR EXISTING CONSTRUCTION. POWER REQUIREMENTS: THE ATM REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND (CONDUIT GROUND IS NOT ACCEPTABLE). THE ATM WILL PROVIDE A POWER CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS SPECIFIED BELOW VAC (+6%, -0%) AT 0 (±%) Hz, SINGLE-PHASE 00-2 VAC (+6%, -0%) AT 60 (±%) Hz, SINGLE-PHASE VAC (±0%) AT 0 (±%) Hz, SINGLE-PHASE VAC (±0%) AT 60 (±%) Hz, SINGLE-PHASE POWER TO THE ATM IS TO BE A DEDICATED SERVICE AND MUST BE PROTECTED BY A SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE VAC (+6%, -0%) SERVICE, DISCONNECT AT 20 AMPERES VAC (±0%) SERVICE, DISCONNECT AT 0 AMPERES THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN POWER USAGE MACHINE STATUS WITH HEATER IDLE (NO TRANSACTION) 24 WATTS 4 WATTS TRANSACTION (DISPENSE 0 WATTS 80 WATTS OR BULK NOTE) IN PROGRESS RAPID PROCESSING 422 WATTS 22 WATTS TRANSACTION IN PROGRESS CONFIGURATION PROCESSOR, SVD, MOTORIZED CARD READER, JOURNAL PRINTER, 80mm RECEIPT PRINTER, IDMbd, 4 HIGH AFD, AND BUILDING AIR PRESSURE BUILDING AIR PRESSURE DIFFERENCES AT THE ATM INSTALLATION LOCATION AFFECT THE INFILTRATION OF OUTSIDE AIR AND ACCOMPANY DIRT. THE ATM WILL OPERATE THROUGH ITS FULL RANGE OF FASCIA TEMPERATURES -4º C TO 4º C (-2º F TO 2º F) WITH ZERO (STATIC) OR POSITIVE AIR PRESSURE DIFFERENTIAL (MEASURED FROM THE INSIDE TO THE OUTSIDE OF THE BUILDING AT THE ATM INSTALLATION LOCATION). IF STATIC OR POSITIVE AIR PRESSURE CANNOT BE MAINTAINED, THE FASCIA LOWER LIMIT TEMPERATURE IS -20º C (-4º F). THE MAXIMUM NEGATIVE AIR PRESSURE ALLOWED IS 0.0" H O. SIGNAL CABLE RUN CONSTRAINTS THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL CABLE RUN WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN. TYPE OF ELECTRICAL RUN FLUORESCENT, NEON OR INCANDESCENT LIGHTING FIXTURES UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT POWER LINES IN GROUNDED CONDUIT WITH SIGNAL CABLES IN GROUNDED CONDUIT BELOW 2 KVA 2- KVA ABOVE KVA 2mm (") 2mm (") 2mm (") 2mm (") 0mm ('-0") 60mm (2'-0") 64mm (2 2") SEPARATION FROM OTHER CABLES 2mm (6") 0mm ('-0") 0mm ( 6") 6mm (") 2mm (6") RAPID PROCESSING SYSTEMS CONFIGURED FOR SIMULTANEOUS IDM (INTELLIGENT DEPOSITORY MODULE) AND (ENHANCED CASH RECYCLING MODULE) OPERATIONS. THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN THE ATM, AND THE TYPE OF TRANSACTION THE ATM IS PERFORMING. VALUES ABOVE ARE BASED ON MEASURED AVERAGES FOR THE CONFIGURATION LISTED. HEAT OUTPUT CONFIGURATION 2 BTU/HR IDLE WITH HEATER 240 BTU/HR TRANSACTION WITH HEATER 46 BTU/HR RAPID PROCESSING WITH HEATER OPERATING ENVIRONMENT: SAFE LOCATION 0º C TO 8º C (0º F TO 00º F) RELATIVE HUMIDITY (NON-CONDENSING) 20 TO 80% AT 2º C (0º F), 20 TO % AT 8º C (00º F) WEIGHT OF UNIT: 2kg (2,8 LBS.) CAUTION LABEL PAGE 2 OF 6 SIGNAL CABLE INSTALLATION CONSTRAINTS: RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE POWER AND LIGHTING CABLE, SIGNAL CABLES HAVE CONDUCTORS AND LIGHT INSULATION AND WILL NOT WITHSTAND AS MUCH STRAIN IN INSTALLATION. 8 ( 2") 0 (20 4 ( 4") 80 ( 6") 40 6") ( 0 6") ( 08 4") (4 2 (2 (2 2") ") (4 6 6") (62 ( SERVICE DOOR FILE NO. -60 REV. 8 SAFE ( 6") BACK ELEVATION VERTICAL SECTION

3 WALL OPENING DETAIL NO. -60 REV. PAGE OF 6 RFILE 0 62 REQUIRED FOR WALLS EXCEEDING 0mm (2") 4 ( 6") 6") (22 6 W.O. (") SEE W ALL OPENING NOTE 22 ( 6") 8 (2") 8 W.O. (2") PLAN VIEW PROVIDE VERTICAL AND HORIZONTAL FLAT PLUMB SURFACE AROUND WALL OPENING FOR PROPER INSTALLATION OF THE ATM 6 ( (2") 8 W.O. ( 6") 6 (") 6 6 (") (") 06 0mm (2") MAXIMUM 6") (2 400 ( REQUIRED W HEN ILLUMINATED SIGNAGE PANEL IS INSTALLED W.O ") (22 SEE W ALL OPENING NOTE 0mm (2") MAXIMUM WALL OPENING NOTE: INSIDE FLOOR LEVEL MUST BE THE SAME AS OUTSIDE SIDEWALK LEVEL FOR OPTIMUM ACCESS. IF INSIDE FLOOR IS HIGHER OR LOWER THAN OUTSIDE, DIMENSION FOR LOCATING WALL OPENING WILL HAVE TO BE ADJUSTED ACCORDINGLY AND OPTIMUM ACCESS REQUIREMENTS WILL NOT BE MET. VERTICAL SECTION EXTERIOR ELEVATION

4 REQUIRED MINIMUM SERVICE AREA REQUIRED MINIMUM SERVICE AREA ALL ELECTRICAL AND DATA CABLES MUST ENTER UNIT IN THIS AREA NOTE: SHOWN IS THE REQUIRED MINIMUM AREA FOR INSTALLATION AND SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO IMPROVE INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE REQUIRED AREA MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE TIME. CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR SPECIAL BUILDING CONDITIONS. (4") 86 ( 2") 8 SAFE ( 6") 6 (2 6") PAGE 4 OF ") (6 (4 2 8 (2 6") (2 2") 4 6") ( 8 (4 6") 8 8 W.O. (") (2") ( 6 ") (20 4 ( 6 ") 8 W.O. (2") ( 6 ") 8 8 ") (4 6 (4") 2 ( 6") 8 ( 4") 2 ( 6") 20 FILE NO. -60 REV. ( PLAN VIEW - REQUIRED MINIMUM SERVICE AREA

5 20 8 SAFE ( 6") ( (2 4") (4 4") (4 4") SAFE 024 6") 22 ( ") ( (2 2 CABLE ENTRY OPENING (SEE NOTE) 46 6") ( 8 2") ( CABLE ENTRY NOTE: ELECTRICAL AND DATA CABLING ENTERS THE ATM THROUGH A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE. CABLES ENTERING THE ATM PASS THROUGH THE POWER CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL OF THE SAFE OVER THE CABLE ENTRY OPENING. CABLING ENTERS FROM THE SIDE OF THE ATM. THE CABLE ENTRY OPENING IS ON THE RIGHT SIDE OF THE SAFE AS VIEWED FROM THE FRONT OF THE CASH DISPENSER. 2mm ( DIA. HOLE FOR ALARM CABLES (SIDE ENTRY) OPENING FOR POWER CORD AND DATA CABLES (SIDE ENTRY) 0 (20 POWER CABLE PLATE 6 (2 4") PLAN/SECTION - SAFE FLOOR ANCHORING HOLES 2 SNAP-OFF DETECTOR () 4mm ( 4") RECESS DIAMETER 8mm ( 6") RECESS 2 (28 6") 2.4mm (") THROUGH-HOLE-DIAMETER () 6mm (2 6") RECESS DIAMETER 8mm ( 6") RECESS 22mm ( THROUGH-HOLE-DIAMETER NOTES: FOR ADDED SECURITY: IT IS RECOMMENDED THAT THE CASH DISPENSER SAFE BE SECURED TO THE FLOOR WITH ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES TO DETERMINE THE APPROPRIATE METHOD FOR YOUR INSTALLATION. ANCHORING THE CASH DISPENSER TO CONCRETE FLOORS: IT IS RECOMMENDED THAT THE CASH DISPENSER BE ANCHORED TO CONCRETE FLOORS WHENEVER POSSIBLE. DIEBOLD RECOMMENDS USING A M20 OR mm ( 4") ANCHOR BOLT THAT IS 20mm ( LONG. CONCRETE FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 02mm (4") THICK FOR ANCHORING TO BE EFFECTIVE. THERE IS NO LIMIT FOR MAXIMUM THICKNESS. ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES. FILE NO. -60 REV. PAGE OF 6

6 CONSUMER ACCESS DIMENSIONS TOP OF TOUCH SCREEN TOP FUNCTION KEY COIN DOOR BAR CODE SCANNER RECEIPT PRINTER CARD READER IDMbd LOWER KEYPAD (MIDDLE EPP KEY) ADVANCED FUNCTION DISPENSER TOP OF TOP ADVANCED RECEIPT KEYPAD IDMbd CARD BAR CODE COIN TOUCH FUNCTION FUNCTION PRINTER (TOP EPP KEY) LOWER READER SCANNER DOOR SCREEN KEY DISPENSER (0 4") (2 6") (46 6") (0 4") (8 (8 (4 6") ( 6") (4 4") (4 4") (2 6") ( 6") (6 6") (8 ( (8 (4 6") (8 (4 (8 - FROM BOTTOM OF SAFE - FROM FRONT EDGE OF BEZEL TOP OF TOUCH SCREEN TOP FUNCTION KEY IDMbd UPPER LCD BAR CODE SCANNER PASSBOOK PRINTER CARD READER RECEIPT PRINTER KEYPAD (MIDDLE EPP KEY) ADVANCED FUNCTION DISPENSER PAGE 6 OF 6 TOP OF TOUCH SCREEN TOP FUNCTION KEY 28 (0 4") (2 6") 8 (46 6") 26 (0 4") - FROM BOTTOM OF SAFE PASSBOOK PRINTER 6 ( 6") - FROM FRONT EDGE OF BEZEL 2 (8 884 (4 6") 4 ( 6") KEYPAD (TOP EPP KEY) 80 (4 4") 0 (4 4") ADVANCED FUNCTION DISPENSER 40 (2 6") ( 6") RECEIPT PRINTER 0 ( 6") 2 (8 26 CARD READER (6 6") 2 (8 BAR CODE SCANNER IDMbd UPPER 062 (4 6") 2 (8 24 (4 6") 2 (8 IDM V UPPER IDMbd LOWER FILE NO. -60 REV. 6 IDM V LOWER (6 6") 2 (8 IDM V UPPER 24 (4 6") 2 (8 - FROM BOTTOM OF SAFE - FROM FRONT EDGE OF BEZEL

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12) MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL OPTEVA 868 THROUGH THE WALL ATM WITH mm ( 2") CEN-L SAFE L00 CALL -800-999-600 22 (9 6") REQUIRED FOR WALLS EXCEEDING 0mm (2") CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND

More information

OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION

OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION L0 CALL -800--600 OPTEVA 88 LOBBY ATM FRONT LOAD WITH 0mm ( 6") CEN III AND CEN IV SAFE CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE PLANNING AND

More information

INSTALLATION INSTRUCTIONS FOR

INSTALLATION INSTRUCTIONS FOR INSTALLATION INSTRUCTIONS FOR MODEL 2240LED www.sportablescoreboards.com 1 Table of Contents 8 X 7 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR

More information

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED INSTALLATION INSTRUCTIONS FOR MODEL 2230LED www.sportablescoreboards.com 1 Table of Contents MODEL 2230LED... 3 8 X 4 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:...

More information

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels The is a 4-channel universal lighting control module designed to support dimming of both forward and reverse phase type loads. A single model supports both 120 and 220-240 Volt electronic and magnetic

More information

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD 1 INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD NOTE TO INSTALLERS: PLEASE RETURN THIS MANUAL TO THE INDIVIDUAL IN CHARGE OF THE SCOREBOARD UPON COMPLETION OF INSTALLATION. The scoreboard

More information

ICS Digital Menu. Installation Guide Version 1.1

ICS Digital Menu. Installation Guide Version 1.1 ICS Digital Menu Installation Guide Version 1.1 Installation Overview This document was written to assist technicians and electricians in installing the ICS Digital Menu. A thorough understanding of electrical

More information

ISP-W 350 till 1200 ISP-R 350 till 1200 ISP-B 350 till 1200 ISP-Motiv 450 till 950 with receiver RF Edition: 05/16 Nr

ISP-W 350 till 1200 ISP-R 350 till 1200 ISP-B 350 till 1200 ISP-Motiv 450 till 950 with receiver RF Edition: 05/16 Nr Installation and technical manual ISP-W / R / B / motives frameless with receiver RF 2 3 ISP-W 350 till 1200 ISP-R 350 till 1200 ISP-B 350 till 1200 ISP-Motiv 450 till 950 with receiver RF Edition: 05/16

More information

Cyclo Series. user manual. MartinArchitectural

Cyclo Series. user manual. MartinArchitectural Cyclo Series user manual MartinArchitectural Measurements are in millimeters 63 Cyclo 02 88 Cyclo 03 1000 81 1190 88 Cyclo 04 98 88 2002 Martin Professional A/S, Denmark. All rights reserved. No part of

More information

Ticker. World Clock. World Clock. Monitor Monitor Monitor. Monitor Monitor Monitor. Monitor Monitor Monitor. Monitor Monitor Monitor 125" 122"

Ticker. World Clock. World Clock. Monitor Monitor Monitor. Monitor Monitor Monitor. Monitor Monitor Monitor. Monitor Monitor Monitor 125 122 Ticker World Clock World Clock 125" 122" 125" Front View 7.3 mm Ultra thin bezel LCD Display (specifications are per display) Weight 65 lbs Dimensions 40.38[1025.7](w) x 22.83[579.8](h) x 5.04[128.1](d)

More information

Kramer Electronics, Ltd. USER MANUAL VM-20HD. Dual 1:10 HD/SD SDI Distribution Amplifier

Kramer Electronics, Ltd. USER MANUAL VM-20HD. Dual 1:10 HD/SD SDI Distribution Amplifier Kramer Electronics, Ltd. USER MANUAL VM-20HD Dual 1:10 HD/SD SDI Distribution Amplifier Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Your VM-20HD Dual 1:10 HD/SD

More information

42 LCD Overhead Video Display Support Specifications Electricity required on the rear curtain wall

42 LCD Overhead Video Display Support Specifications Electricity required on the rear curtain wall 42 LCD Overhead Video Display Support Specifications Electricity required on the rear curtain wall NOTE: All of these documents are in PDF format located at www.steltronicusa.com To install the 42 LCD

More information

Label Applicator HERMA 400

Label Applicator HERMA 400 Label Applicator HERMA 400 Info GB V6.0 / 30.3.07 [ Facts & Data ] R Constructional variant Right-hand or left-hand version, always flexible to use L Power supply / Line voltage Max. power consumption

More information

42 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall)

42 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall) 42 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall) NOTE: All of these documents are in PDF format located at www.steltronicusa.com To install the 42 LCD

More information

SQM40/41 Actuators for air and gas dampers

SQM40/41 Actuators for air and gas dampers SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

For Sales & Information, Call Toll Free: (888)

For Sales & Information, Call Toll Free: (888) PCR Outline Dimensions 2.75" (69.8 mm) 0.44" (11 mm) 0.25" (6.3 mm) (-) (+) 15.8" (401 mm) 9.3" (236 mm) Nameplate 1.25" (31.8 mm) 3.0" (76 mm) 7.40" (188 mm) 12.63" (321 mm) R 0.219" (R 5.56 mm) Serial

More information

Identification - electrical services

Identification - electrical services Identification - electrical services Aesthetic All live phase cable sheathing to be brown coloured and neutral phase cable sheathing to be blue coloured, all labelled L1, L2, L3 & N respectively in accordance

More information

Kramer Electronics, Ltd.

Kramer Electronics, Ltd. Kramer Electronics, Ltd. Preliminary USER MANUAL Models: VM-5ARII, Video Audio Distribution Amplifier VM-20ARII, 1:20 Programmable Video Audio Distributor VM-1411, 1:10 Video/Audio Distributor Contents

More information

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras Eng Installation Instructions F D E NL I IMPORTANT SAFEGUARDS 1. Read Instructions All the safety and operating instructions should be read before

More information

Dell Wyse 5030 PCoIP Zero Client

Dell Wyse 5030 PCoIP Zero Client Dell Wyse 5030 PCoIP Zero Client User Guide Regulatory Model: PxN Regulatory Type: PxN001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection

More information

RT AUDIO RETRACTABLE CABLE

RT AUDIO RETRACTABLE CABLE AUDIO RETRACTABLE CABLE Welcome! Thank you for purchasing the MINI-ME RT300-134 audio Cable Retractor. We know you will find it easy to install, easy to use and easy to maintain. Our goal is to provide

More information

HighBand 25. TrueNet Category 6 Solutions

HighBand 25. TrueNet Category 6 Solutions HighBand 25 TrueNet Category 6 Solutions The highest performing cross-connect system in the world. A unique high-density solution with superior cable management. ADC KRONE s HighBand 25 cross connect solution

More information

SPECIFICATION NO Model 207 Automatic GTAW Welding System

SPECIFICATION NO Model 207 Automatic GTAW Welding System 1.0 Introduction The Model 207 is a completely self-contained Gas Tungsten Arc Welding (GTAW) System requiring only input power, inert gas and AMI Welding Head (or manual torch) for operation. Its small

More information

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance

Linatron - M9 & M9A. Modular high-energy X-ray source. 2.0 Performance The Linatron -M is a modular system. The control console, modulator, and RF unit are common to all model configurations. Only the X-ray head changes to match the application. The Linatron - M is designed

More information

Room Recommendations for the Cisco TelePresence System 3210

Room Recommendations for the Cisco TelePresence System 3210 CHAPTER 2 Room Recommendations for the Cisco TelePresence System 3210 Revised: February 20, 2012, This chapter provides you with general room recommendations for the Cisco TelePresence System 3210 (CTS

More information

Capacitance Limit Detection nivotester FTC 420/421/422

Capacitance Limit Detection nivotester FTC 420/421/422 Technical Information TI 127F/00/en Capacitance Limit Detection nivotester FTC 420/421/422 Limit switches in Minipac design for liquids and bulk solids Application Nivotester FTC 420...422 capacitive limit

More information

Modular pulse operated latching relay 16 A

Modular pulse operated latching relay 16 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,

More information

RT USB RETRACTABLE CABLE

RT USB RETRACTABLE CABLE USB RETRACTABLE CABLE Welcome! Thank you for purchasing the MINI-ME RT300-160 USB C to USB A cable retractor. We know you will find it easy to install, easy to use and easy to maintain. Our goal is to

More information

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Model DT-311J And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL 1. GENERAL The DT-311J DIGITAL

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective

More information

Brilliant indoor display solutions. Now ready for a close-up.

Brilliant indoor display solutions. Now ready for a close-up. Video Wall Solution Brilliant indoor display solutions. Now ready for a close-up. High-Density Surface Mount Diode (SMD) Indoor LED displays have revolutionized large-scale video communications, delivering

More information

ELECTRICAL SAFETY INSPECTION REPORT

ELECTRICAL SAFETY INSPECTION REPORT ELECTRICAL SAFETY INSPECTION REPORT A PLUS INDUSTRIES LIMITED. Plot-28, Milk Vita Rd., Section-07, Mirpur, Dhaka Factory List: 1. A Plus Industries Ltd. Inspected by: Yoon Report Generated by: Nezar Inspected

More information

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 25A power contactors silent CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning - Connection...

More information

HDBT Installation Guide

HDBT Installation Guide KRAMER ELECTRONICS LTD. HDBT Installation Guide MODELS: Kramer HDBT Cable Recommendations for Usage and Termination Guidelines For the latest information on our products and a list of Kramer distributors,

More information

PCR AUTOMATIC HEAT TREATMENT CONSOLE

PCR AUTOMATIC HEAT TREATMENT CONSOLE Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL

More information

Church Layout Medium Advanced

Church Layout Medium Advanced Specifier Product Information Church Layout Medium Advanced System Summary This summary is intended to explain, in general terms, some of the possible uses and reasons for having the recommended equipment

More information

Safety Codes Council Conference Banff C Panel Discussion

Safety Codes Council Conference Banff C Panel Discussion Safety Codes Council Conference Banff 2014 90 C Panel Discussion Tim Driscoll OBIEC Consulting Ltd. George Morlidge Fluor Canada Ltd. Scott Basinger Eaton Canada René Leduc Marex Canada Limited Perspectives

More information

32 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall)

32 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall) 32 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall) NOTE: All of these documents are in PDF format located at www.steltronicusa.com To install the 32 LCD

More information

NewScope-7A Operating Manual

NewScope-7A Operating Manual 2016 SIMMCONN Labs, LLC All rights reserved NewScope-7A Operating Manual Preliminary May 13, 2017 NewScope-7A Operating Manual 1 Introduction... 3 1.1 Kit compatibility... 3 2 Initial Inspection... 3 3

More information

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Deliveryprogramme Circuitbr.,3pmotorprotection Partno. Articleno. 265784 NZMN4-ME875 Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation type Fixed Release

More information

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire MultiMac SM Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire Features of the MultiMac SM Electronics Simultaneous Coil and/or Rotary Probe operation Differential

More information

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA Lifestyle Dual Channel Programmer for heating AND hot water Installation and User Instructions DUAL CHANNEL 06490197001 ISSA INSTALLATION INSTRUCTIONS PLEASE NOTE: INSTALLATION MUST ONLY BE CARRIED OUT

More information

RT USB RETRACTABLE CABLE

RT USB RETRACTABLE CABLE USB RETRACTABLE CABLE Welcome! Thank you for purchasing the MINI-ME RT300-155 USB cable retractor. We know you will find it easy to install, easy to use and easy to maintain. Our goal is to provide our

More information

Solid-State Digital Timer

Solid-State Digital Timer Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,

More information

DISTRIBUTION AMPLIFIER

DISTRIBUTION AMPLIFIER MANUAL PART NUMBER: 400-0045-005 DA1907SX 1-IN, 2-OUT VGA/SVGA/XGA/UXGA DISTRIBUTION AMPLIFIER USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL...2 GUIDELINES FOR RACK-MOUNTING...2

More information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100 DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective

More information

IndyGo Facility Upgrades Project 35671EE

IndyGo Facility Upgrades Project 35671EE SECTION 260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Identification for raceways. 2. Identification of power and control cables. 3. Identification for

More information

PNP300 / PNP300UN / PNP350

PNP300 / PNP300UN / PNP350 DOCUMENT NUMBER 400-0114-003 / UN / PNP350 Pop N Plug Slim INTERCONNECT BOX USER'S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS...2 GENERAL...2 INSTALLATION...2 CLEANING...2 ABOUT YOUR /300UN/350...3

More information

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L T, T8, TC-L Electronic ballasts PC T PRO lp 80 W 0 0 V 0/0/0 Hz, HO L D,1 0, 1 side fixing feature side fixing feature ø,1 defined lamp warm start is 1. s constant light output independent of fluctuations

More information

Lt DELTA USA, Inc

Lt DELTA USA, Inc Infrared LOOP SCANNER Rota-Sonde TS2006 Infrared - high sensitivity 480 F or 750 F Quick and easy commissioning Self-monitoring and alarm functions Lt 1037 1 Applications R o t a - S o n d e TS2 0 0 6

More information

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire MultiMac Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire Inspection Features Versatile Threshold Selection Challenging test conditions are made simple

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

PAM-1840 Preamplifier Operation Manual

PAM-1840 Preamplifier Operation Manual PAM-1840 Preamplifier Operation Manual 1 TABLE OF CONTENTS INTRODUCTION 3 GENERAL INFORMATION 4 SPECIFICATIONS 4 OPERATING INSTRUCTIONS 5 MAINTENANCE 6 2 INTRODUCTION BEFORE APPLYING POWER Review this

More information

Power Injector 1520 Series

Power Injector 1520 Series Power Injector 1520 Series Technical Specifications Input voltage 100 to 240 VAC Output voltage 56.0 VDC Voltage range tolerance 54 VDC to 57 VDC Maximum current 1.43 A No load current 15 ma 56VDC@0.71A

More information

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe EFC, EFCe Systems Electronic Frequency Control Continuously variable speed control using frequency converter technology With the EFC and EFCe system Bock offers the most efficient means of adapting the

More information

Installation Guide VL-MV10. Model No.

Installation Guide VL-MV10. Model No. Installation Guide Model Name Model No. Main Monitor Station VL-MV0 R Main monitor station is described as "main monitor" in this guide. R In this guide, the suffix of each model number (e.g., the "EX"

More information

Automatic Test System AT-S + with STAR + Technology Features

Automatic Test System AT-S + with STAR + Technology Features AT-S + with STAR + Technology Features AT-S + offers all the known benefits of our STAR technology, now also for AC safety power sources. It is the perfect symbiosis of CEWA GUARD and STAR technology.

More information

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION COMMUNICATIONS HORIZONTAL CABLING SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors including patch panels. 3. Cabling identification

More information

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL www.prolight.co.uk TRANSCENSION 6-CHANNEL PACK (order code: BOTE40) USER MANUAL SAFETY WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this

More information

1.4 Conduit Position Clearance from Wall mm minimum mm+ prefer

1.4 Conduit Position Clearance from Wall mm minimum mm+ prefer EQUIPMENT ELECTRONIC PODIUM U of T STANDARD TEACHING STATION PROJECT None - Typical specification sheet DATE updated Feb 2011 BY Burl Crone, OSM, UofT (St. George) burl.crone@utoronto.ca 416-978-8613 0

More information

Mini LED Pin Spot Light Model: PLS00571

Mini LED Pin Spot Light Model: PLS00571 Mini LED Pin Spot Light Model: PLS00571 1 Please read these instructions carefully before use and retain for future reference. IMPORTANT SAFETY INFORMATION When using electrical appliances basic safety

More information

Small System Packages. Strand Dimming Systems

Small System Packages. Strand Dimming Systems 24 Dimmer Advanced System Model 98506 Four SD 6C dimmer packs Permanent Manual & portable Memory lighting console Rack with locking front door. Twelve 15-32 Zoom spotlights Twelve 6 inch Fresnels Three

More information

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0091-003 TNP500 Universal Tilt N Plug Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the TNP100 Tilt N Plug Interconnect Box is greatly appreciated. We are sure you

More information

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA .5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.

More information

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab* Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab* General Scope of Work: Supply and installation of Computer Laboratory setup in MIU Location of Installation:

More information

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor

Kramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor Kramer Electronics, Ltd. USER MANUAL Model: VM-1045 Video Component Distributor Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 1 3 Overview 3 4 Your VM-1045 Video Component Distributor

More information

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel 1993 Specifications CSJ 0924-06-223 SPECIAL SPECIFICATION 1160 8:1 Video (De) Mux with Data Channel 1. Description. This Item shall govern for furnishing and installing an 8 channel digital multiplexed

More information

The Chan-L-Wire Pro Series Lighting Distribution

The Chan-L-Wire Pro Series Lighting Distribution Lighting Distribution System Offers Maximum Flexibility The Chan-L-Wire Pro Series Lighting Distribution System offers maximum flexibility while saving up to 40% in labor installation costs. The system

More information

Site Installation Model MP-8433

Site Installation Model MP-8433 Site Installation Model MP- Rev. //0 SCOREBOARD SITE INSTALLATION INSTRUCTIONS CAUTION: All American Scoreboards (AAS) recommends the sign be installed by a licensed contractor, and must meet all local

More information

Spectra Batten (Order code: LEDJ95)

Spectra Batten (Order code: LEDJ95) www.prolight.co.uk Spectra Batten (Order code: LEDJ95) Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this equipment away from rain,

More information

FiberLink 7142 Series

FiberLink 7142 Series MANUAL FiberLink 7142 Series 4 Channels of Composite Video and 8 Channels of Audio over one single mode or multimode fiber Installation and Operations Manual WWW.ARTEL.COM FibeLink 7142 Series Contents

More information

Site Installation Model MP-8424

Site Installation Model MP-8424 Site Installation Model MP- Rev. //0 SCOREBOARD SITE INSTALLATION INSTRUCTIONS CAUTION: All American Scoreboards (AAS) recommends the sign be installed by a licensed contractor, and must meet all local

More information

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE MANUAL PART NUMBER: 400-0430-001 1-IN 1-OUT LINE DRIVER WITH UALIZATION + AUDIO USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL...2 GUIDELINES FOR RACK-MOUNTING...2 INSTALLATION...2

More information

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

ALO 030 MKII. 30 Watt DMX LED scanner. User manual ALO 030 MKII 30 Watt DMX LED scanner User manual Safety instructions WARNING! Always keep this device away from moisture and rain! Hazardous electrical shocks may occur! WARNING! Only connect this device

More information

Operating Instructions Dimmer for V Incandescent Lamps

Operating Instructions Dimmer for V Incandescent Lamps Operating Instructions Incandescent Lamps 1. Safety instructions Attention: Electrical equipment must be installed and fitted only by qualified electricians and in observance of the current accident prevention

More information

TeamWork Installation Guide

TeamWork Installation Guide C G G 00-0V/ A MAX TX RX +V APARATUS US 0 TeamWork Installation Guide TeamWork TeamWork is a fully customizable collaboration system comprised of an switcher, Show Me cables, a control processor, and a

More information

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer

Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer Instruction Manual Fixed Speed Vortex Mixer Analog Vortex Mixer Digital Vortex Mixer Pulsing Vortex Mixer Table of Contents Package Contents............ 1 Warranty............ 1 Installation............

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 10W 350mA fixc lp SNC2 ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 350 ma Max. output power 10.2 W Up to 80 % efficiency For

More information

Distributed Design Series

Distributed Design Series D10SUB 10-INCH FEATURES Powerful, high-impact bass response Internal passive low-pass crossover Spring loaded Drop-Stop installation assistant tabs support the back can on the included rails and C-ring

More information

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Type: NZMN1 A100 Article No.: 259085 Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Description Rated current = rated uninterrupted current Setting range 3 pole I

More information

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV REV. 1.0 Fully ly Automaticti Motorised Satellite t TV System User s manual Customer Help Line: 1300 139 255 Support Email: support@satkingpromax.com.au Website: www.satkingpromax.com.au www.satkingpromax.com.au

More information

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features High-performance Vision Sensor Advanced algorithm enables ultra high speed and maximum flexibility Features Inspection and positioning that was difficult with previous vision sensors is now surprisingly

More information

Ultra Quiet Series Electric Air Handler

Ultra Quiet Series Electric Air Handler Residential & Light Commercial HVAC Ultra Quiet Series Electric Air Handler 1 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz The Fedders multi-position air handlers, when matched with our air conditioners

More information

Model 1421 Distribution Amplifier

Model 1421 Distribution Amplifier Model 1421 Distribution Amplifier Installation and Operating Instructions The 1421 Distribution Amplifier provides four independent, wide bandwidth outputs from one video input. The unit is color compatible

More information

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase.

1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase. (1) Specifications: 1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase. 2. Power consumption Normal 2W (MAX 30W) 3. Standard time signal Quartz oscillation 4. Time accuracy

More information

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 DATASHEET - NZMC1-A160 Circuit-breaker, 3p, 160A Part no. NZMC1-A160 Catalog No. 283296 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection

More information

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher Kramer Electronics, Ltd. USER MANUAL Model: VS-120 20 x 1 Sequential Video Audio Switcher Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Installing the VS-120 in

More information

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE MANUAL PART NUMBER: 400-0031-003 PRODUCT REVISION: 1 HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE INTRODUCTION Thank you for your purchase of the Transcoder. We are certain that you will find

More information

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.

1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE. Art.-No.: 1202 URE Operationsmanual 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage to

More information

CM-S23349SV. Vari-Focal IR Bullet Camera

CM-S23349SV. Vari-Focal IR Bullet Camera Vari-Focal IR Bullet Camera User s Guide CM-S23349SV SAFETY PRECAUTIONS WARNING 1. Be sure to use only the standard adapter that is specified in the specification sheet. Using any other adapter could cause

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Circuit-breaker,3p,160A Partno. NZMN2-M160 CatalogNo. 265724 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation

More information

Basic Vortex Mixer Standard Vortex Mixer Advanced Vortex Mixer Pulsing Vortex Mixer

Basic Vortex Mixer Standard Vortex Mixer Advanced Vortex Mixer Pulsing Vortex Mixer Instruction Manual Manual Basic Vortex Mixer Standard Vortex Mixer Advanced Vortex Mixer Pulsing Vortex Mixer Table of Contents Package Contents............... 1 Warranty............... 1 Installation...............

More information

110LP MOON Series. Phono Preamplifier. Owner s Manual

110LP MOON Series. Phono Preamplifier. Owner s Manual Phono Preamplifier Owner s Manual Owner s Manual I Table of Contents Introduction 4 Unpacking 5 Installation & Placement 5 Circuit Board Layout s 6 Internal Adjustments 7 Rear Panel Connections 8 Operating

More information

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s dv/dt filter plus Voltage Peak Limiter Safety information 1 General 2 SINAMICS SINAMICS G130 Operating Instructions Mechanical installation 3 Electrical

More information