3 line filters for converters and power electronics
|
|
- Silvia Dennis
- 5 years ago
- Views:
Transcription
1 53/35 V, 5/ Hz, A, 5 C Ordering code: Date: Version: 6 EPCOS AG 27. Reproduction, publication and dissemination o this data sheet, enclosures hereto and the inormation contained therein without EPCOS prior express consent is prohibited.
2 Construction 3 line ilter Metal case Book size Features High insertion loss Optimized or long cable Easy to install Low weight Compact design Degree o protection IP 2 1) Design complies with IEC 939, UL 1283, CSA 22.2 No.8 UL and cul approval Optimized or long motor cable and operation under ull load EN 5511, Class A & B Applications Frequency converters or motor drives, e.g. elevators pumps traction systems conveyor systems HVAC systems (heating, ventilation and air conditioning) Power supplies Textile machines Terminals Line side: inger save terminal blocks Load side: inger save terminal blocks Marking Marking on component: manuacturer s logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code Minimum marking on packaging: mauacturer s logo, ordering code, date code, quantity 1 ) To IEC 529:21
3 Typical circuit diagram B84143D16R127 B84143D36R127: LINE LOAD L1 L1 L2 L2 L3 L3 PE B84143D5R127 B84143D2R127: LINE LOAD L1 L1 L2 L2 L3 L3 PE
4 Technical data and measuring conditions Rated voltage VR 53/35 V AC Rated requency R 5/ Hz Test voltage line to line or 2 s U test 22 V DC Test voltage line to case or 2 s U test 27 V DC Rated temperature T R 5 C Overload capability (thermal) or 3 min per hour or 1.5 x I R or 3 s per hour 2.5 x I R Climatic category (IEC 68 1) 25//21 Typical motor cable length to comply with DIN EN 5511 (23) Ordering code I R EMC Limits according to DIN EN 5511 (23) 1) A class A class B B84143D16R m m B84143D25R m m B84143D36R m m B84143D5R m 2m B84143D75R m 2m B84143D9R m 2m B84143D12R m 2m B84143D15R m 2m B84143D2R m 2m 1): Typical values. The motor cable length depends on the clock requency and the disturbance level o the requency converter and migth dier rom above mentioned indicated cable lenghts. Please note pages 16 and 17.
5 Characteristics and ordering codes I R Terminal cross section I 2) leak R typ Approx. weight A mm 2 ma mω kg Ordering code Approvals 16 4 < 37 14,5 2,5 B84143D16R127 X X 25 6 < 43 7, 2,5 B84143D25R127 X X 36 1 < 4 4,5 3,5 B84143D36R127 X X 5 25 < 55 2,5 5,5 B84143D5R127 X X 75 5 < 73 1, 8, B84143D75R127 X X 9 5 < 166 1, 8, B84143D9R127 X X < 166 1, 14,5 B84143D12R127 X X < 136,5 17, B84143D15R127 X X 2 95 < 139,5 18,5 B84143D2R127 X X X = approval granted = in preparation 2) 3 phase operation in TN network; maximum voltage = U R ; requency = 5 Hz without harmonics; tolerance o capacitors 2%/ %; worst case positioning o the components; unbalance 2% according EN 51:2.
6 Dimensional drawings B84143D16R127 all dimensions in mm
7 Dimensional drawings B84143D25R127 all dimensions in mm
8 Dimensional drawings B84143D36R127 all dimensions in mm
9 Dimensional drawings B84143D5R127 all dimensions in mm
10 Dimensional drawings B84143D75R127; B84143D9R127 all dimensions in mm
11 Dimensional drawings B84143D12R127; B84143D15R127 all dimensions in mm
12 Dimensional drawings B84143D2R127 all dimensions in mm
13 Insertion loss (typical values at Z = 5 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) dierential mode (symmetrical) B84143D16R127 B84143D25R Hz Hz B84143D36R127 B84143D5R Hz Hz
14 Insertion loss (typical values at Z = 5 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) dierential mode (symmetrical) B84143D75R127 B84143D9R Hz Hz B84143D12R127 B84143D15R Hz Hz
15 Insertion loss (typical values at Z = 5 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) dierential mode (symmetrical) B84143D2R Hz
16 Caution and warnings Please note the advices in our data book EMC Filters (latest edition); attention should be paid to the chapter General saety notes. It shall be ensured that only qualiied persons (electricity specialists) are engaged on work such as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger o electric shock. EMC ilters contain components that store an electric charge. Dangerous voltages can continue to exist at the ilter terminals or longer than ive minutes even ater the power has been switched o. The protective earth connections shall be the irst to be made when the EMC ilter is installed and the last to be disconnected. Depending on the magnitude o the leakage currents, the particular speciications or making the protective earth connection must be observed. Impermissible overloading o the EMC ilter, such as with circuits able to cause resonances, impermissible voltages at higher requencies etc. can lead to bodily injury and death as well as cause substantial material damages (e.g. destruction o the ilter housing). EMC ilters must be protected in the application against impermissible exceeding o the rated currents by overcurrent protective. In case o leakage currents > 3.5 ma you shall mount the PE conductor stationary with the required cross section beore beginning o operation and save it against disconnecting. For leakage currents I L 4) < 1 ma the PE conductor must have a KU value 3) o 4.5; or leakage currents I L 1 ma the PE conductor must have a KU value o 6. 3) The KU value (symbol KU) is a classiication parameter o saety reerred ailure types designed to ensure protection against hazardous body currents and excessive heating. A value o KU = 4.5 with respect to interruptions is attained: with a permanently connected protective earth circuit 1.5 mm 2 with a protective earth circuit 2.5 mm 2 connected via shroud connectors (IEC 39 2). KU = 6 with respect to interruptions is achieved or ixed connection lines 1 mm 2 where the type o connection and line layout correspond to the requirements or PEN conductors as speciied in relevant standards. 4) I L = leakage current let go
17 Important notes The ollowing applies to all products named in this publication: 1. Some parts o this publication contain statements about the suitability o our products or certain areas o application. These statements are based on our knowledge o typical requirements that are oten placed on our products in the areas o application concerned. We nevertheless expressly point out that such statement cannot be regarded as binding statements about the suitability o our products or a particular customer application. As a rule, EPCOS is either unamiliar with individual customer applications or less amiliar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product speciication is suitable or use in a particular customer application. 2. We also point out that in individual cases, a malunction o electronic components or ailure beore end o their usual service lie time cannot be completely ruled out in the current state o the art, even i they are operated as speciied. In customer applications requiring a very high level o operational saety and especially in customer applications in which the malunction or ailure o a passive electronic component could endanger human lie or health (e.g. in accident prevention or lie saving systems), it must thereore be ensured by means o suitable design o the customer application or other action taken by the customer (e.g. installation o protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event o malunction or ailure o a passive electronic component. 3. The warnings, cautions and product speciic notes must be observed. 4. In order to satisy certain technical requirements, some o the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useul inormation on this will be ound in our Material Data Sheets on the Internet ( Should you have any more detailed questions, please contact our sales oices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change rom time to time. The same is true o the corresponding product speciications. Please check thereore to what extent product descriptions and speciications contained in this publication are still applicable beore or when you place an order. We also reserve the right to discontinue production and delivery o products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aorementioned does not apply in the case o individual agreements deviating rom the oregoing or customer speciic products. 6. Unless otherwise agreed in individual contracts, all orders subject to the current version o the General Terms o Delivery or Products and Services in the Electrical Industry published by the the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu X, CeraDiode, CSSP, CTVS, DSSP, MiniBlue, MKK, MLSC, MotorCAP, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further inormation will be ound on the Internet at 1
EMC filters. 4-line filters for installations and systems Rated current 6 to 125 A. Date: January 2006
EMC ilters 4-line ilters or installations and systems Rated current 6 to 125 A Series/Type: Date: January 2006 EPCOS AG 2006. Reproduction, publication and dissemination o this data sheet and the inormation
More informationKRF EMC Filters Installation, Operation and Maintenance Manual
KRF EMC Filters Installation, Operation and Maintenance Manual KRF EMC Filters limit high frequency noise, as well as: Reduce interference Protect sensitive equipment Eliminate drive cross-talk Meet FCC
More informationFilm Capacitors Power Factor Correction
Series/Type: Ordering code: Date: August 2010 Version: 2 entered in headers and footers! Please fill in the table and then change the color to "white". This ensures that the table disappears (invisible)
More informationPower over Ethernet Transformers 60 W series
Series/Type: Ordering code: 0060A** Date: 2018-01-15 Version: 1 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change
More informationFilm Capacitors Power Factor Correction
Series/Type: Ordering code: Date: November 2010 Version: 4 entered in headers and footers! Please fill in the Film Capacitors Power Factor Correction Identification/Classification 2 (header 2 + bottom
More informationFilm Capacitors AC Capacitors Application note
Drive Circuit for Induction Motor Control, using EPCOS LCap Series Series/Type: Date: 2012-12-04 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please
More informationFilm Capacitors Power Factor Correction
Series/Type: Ordering code: Date: August 2010 Version: 2 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the
More informationFilm Capacitors Power Factor Correction
Series/Type: Ordering code: Date: January 2018 Version: 9 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the
More informationSAW components. SAW RF filter. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Base stations LTE band 27. Date: October 31, 2016 Version: 2.
RF360 Europe GmbH A Qualcomm TDK Joint Venture Base stations LTE band 27 Series/type: Ordering code: B39821U410 Date: October 31, 2016 Version: 2.0 RF360 products mentioned within this document are offered
More informationPower Factor Correction Power Quality Solutions
EPCOS Product Profile 2013 Power Factor Correction Power Quality Solutions www.epcos.com Contents Power Quality Solutions Preview 3 PFC capacitor series overview 6 PQS key components overview 8 Important
More informationPower Factor Correction Power Quality Solutions
EPCOS Product Profile 2016 Power Factor Correction Power Quality Solutions www.epcos.com Contents Power Quality Solutions Preview 3 PFC capacitor series overview 6 PQS key components overview 8 Important
More informationFilters for Power Lines (Low Leakage Current)
Filters for Power Lines (Low Leakage Current) 40 to 100 A, 100 db from 150 khz Series/Type: Date: January 2004 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures
More informationSINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS
SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical
More informationOperating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics
Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical
More informationOperating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130
Operating Manual (Edition 04/2004) sinamics Line Reactors SINAMICS G130 Contents 1. Safety Information 2 2. General 5 3. Mechanical Installation 6 4. Electrical Installation 8 5. Technical Specifications
More informationSINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS
SINAMICS G130 Operating Instructions 03/2013 SINAMICS s dv/dt filter plus Voltage Peak Limiter Safety information 1 General 2 SINAMICS SINAMICS G130 Operating Instructions Mechanical installation 3 Electrical
More informationAC Line Rated Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC
AC Line Rated Disc Capacitors Class X1, 760 V AC, Class Y1, 500 V AC EATURES Complying with IEC 60384-14, 3 rd edition High reliability Vertical (inline) kinked or straight leads Material categorization:
More informationHYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.
Linear / area dimming Constant current LED driver DALI Dimmable Product description Dimmable built-in constant current LED Driver Adjustable output current between 1,050 and 1,750mA via DIP switch Max.
More informationLED Driver Linear / area fixed output
Driver LC 10W 350mA fixc lp SNC2 ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 350 ma Max. output power 10.2 W Up to 80 % efficiency For
More informationSystem 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions
Order No. : 0303 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage
More informationPower Injector 1520 Series
Power Injector 1520 Series Technical Specifications Input voltage 100 to 240 VAC Output voltage 56.0 VDC Voltage range tolerance 54 VDC to 57 VDC Maximum current 1.43 A No load current 15 ma 56VDC@0.71A
More informationHYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.
Constant current LED driver DALI Dimmable Product description Dimmable Independent constant current Adjustable output current between 350 and 1,050mA via DIP switch Max. output power 35 W Up to 88 % efficiency
More informationModel Number Structure
Cycle Control Units CSM DS_E_7_1 Refer to Safety Precautions for All Power Controllers. Used in Combination with the to Enable High-precision Temperature Control Use cycle control to achieve power control
More informationLED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series
Driver LC 200W 1050mA UNV ADV IND ADVANCED series Product description Independent constant current LED Driver For dry, damp and wet locations Max. output power 200 W Up to 93.7 % efficiency For luminaires
More informationT5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L
T, T8, TC-L Electronic ballasts PC T PRO lp 80 W 0 0 V 0/0/0 Hz, HO L D,1 0, 1 side fixing feature side fixing feature ø,1 defined lamp warm start is 1. s constant light output independent of fluctuations
More informationModel 1421 Distribution Amplifier
Model 1421 Distribution Amplifier Installation and Operating Instructions The 1421 Distribution Amplifier provides four independent, wide bandwidth outputs from one video input. The unit is color compatible
More informationPHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series
Product description Fixed output built-in LED Driver Constant current LED Driver Output current 900 ma Max. output power 40 W Nominal life-time up to 30,000 h For luminaires of protection class I and protection
More informationModular Power System acc. VG MoFess Module for Military Ground Vehicles
This new modular Power System for Military Ground Vehicles based on a standard box incorporating up to three different power modules. The power inlet module (230 V AC) includes line filter, lightning protection
More informationTOSHIBA Industrial Magnetron E3328
TOSHIBA E3328 is a fixed frequency continuous wave magnetron intended for use in the industrial microwave heating applications. The average output power is 3kW in the frequency range from 2450 to 2470
More informationGear Pump Units For single-line centralized lubrication systems
1-1202-EN Gear ump Units For single-line centralized lubrication systems MFE5-KW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,
More informationllen-bradley 194R-HM4-NFPA3
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationLED MODULES READYLINE DL
LED MODULES READYLINE DL BUILT-IN MODULE LED-MODULE READYLINE DOWNLIGHT DL WU-M-538 / WU-M-539 / WU-M-540 Typical Applications Downlights Replacement for CFL DIRECT MAINS CONNECTION REDUCED FLICKER HIGH
More informationTGL2210-SM_EVB GHz 100 Watt VPIN Limiter. Product Overview. Key Features. Applications. Functional Block Diagram. Ordering Information
.5 6 GHz Watt VPIN Limiter Product Overview The Qorvo is a high-power receive protection circuit (limiter) operating from.5-6ghz. Capable of withstanding up to W incident power levels, the allows < dbm
More information1 Safety instructions. 2 Device components. 3 Function. Light Management Relay switch insert 2-channel. Art.-No.: 1202 URE.
Art.-No.: 1202 URE Operationsmanual 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause damage to
More informationTRISHALA ELECTROLYTICS PVT LTD BANGALORE
P TRISHALA ELECTROLYTICS PVT LTD BANGALORE- 560044 AC MOTOR START ALUMINIUM ELECTROLYTIC CAPACITORS (Aluminum Body / Bakelite (Phenolic) Body) Scope Aluminum electrolytic Motor Start Capacitors are used
More informationLED Driver Compact fixed output
Driver LC 40W 900mA fixc C SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 900 ma Max. output power 40 W Nominal life-time up to 50,000
More informationPanel-Mounted Thermostat
Data Sheet 602026 Page 1/7 Panel-Mounted Thermostat EM Series Special features Safety temperature monitor STW (STB) Safety temperature limiter STB Tested according to DIN EN 14597 and PED 2014/68/EU Brief
More informationHigh performance circuit breakers
Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics
More informationR&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution
Secure Communications Product Brochure 01.00 R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution R&S ADMC8 Multicoupler At a glance The R&S ADMC8 is a multicoupler specifically
More informationLED Driver Compact fixed output
Driver LC 10W 250mA fixc R ADV ADV series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 250 ma For luminaires of protection class II For ambient temperatures
More informationR&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications
ZN-Z151_152_153_dat-sw_en_3607-0881-22_v0100_cover.indd 1 Data Sheet 01.00 Test & Measurement R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications 07.10.2014 11:35:47 CONTENTS Definitions... 3 Measurement
More informationLED Driver Compact fixed output
Driver LC 45W 1050mA fixc C SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 1,050 ma output power 45 W Nominal life-time up to 50,000
More informationMICROMASTER Encoder Module
MICROMASTER Encoder Module Operating Instructions Issue 01/02 User Documentation Foreword Issue 01/02 1 Foreword Qualified Personnel For the purpose of this Instruction Manual and product labels, a Qualified
More informationMKH 8060 Directional studio microphone
MKH 8060 Directional studio microphone Instruction manual Contents Contents Important safety information... 2 The MKH 8060... 3 Delivery includes... 4 Product overview... 5 Putting the MKH 8060 into operation...
More informationDLP200M 2 Relay Module for Heating and Cooling Plants
Product Sheet TH6.24 Thermostat Type DLP200M DLP200M 2 Relay Module for Heating and Cooling Plants The DLP 200 M is a relay module for activation of loads (namely thermal actuators or circulators) in wireless
More informationSoft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit
DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer
More informationRecommended Land Pattern: [mm]
Dimensions: [mm] Recommended Land Pattern: [mm] Absolute Maximum Ratings (Ambient Temperature 25 C): Properties Test conditions Value Unit Power Dissipation (Red) P Diss R 48 mw 2 3 1 4 2,2,5 Cathode Mark
More informationRexroth IndraDrive Fc Compact, high-performance standard frequency converters
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Simply a better drive 2
More informationSITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.
SITOP power supply Technical data, April 2010 SITOP Power Supply Answers for industry. SITOP reliable power supply Efficient operation of a machine or plant requires a reliable, constant power supply.
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationFeatures. High Brightness SMD LED Light source
www.edison-opto.com Solid-State Lighting Series 5W MR16 DATASHEET Features High Brightness SMD LED Light source Ecologically Friendly Energy Efficient General Information... 1 Product Dimensions... 2 Product
More informationLINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS
MUSIUM RESTAURANT SOUVENIR SHOP EXIT LinkRay Modulators 12 V / 24 V Constant-voltage Applications LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE LINK-RAY TM MODULATORS FOR CONSTANT-VOLTAGE APPLICATIONS 186755
More informationRecommended Land Pattern: [mm]
Dimensions: [mm] Recommended Land Pattern: [mm] Absolute Maximum Ratings (Ambient Temperature 2 C): Properties Test conditions Value Unit,6 u,1 3 1 2,2 u,1 6 4 2 2,7 u,1,84 u,1 4,2 1,8 1,2 1 2 3 4 6,6
More informationXW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations
Terminal Boxes XWD CSM_XWD_DS_E Simple Wiring of Sensor Actuators Greatly reduce wiring in combination with the Smartclick XS. Insert the connector and turn / of a turn to lock the connectors. Higher rated
More informationOperating Instructions Dimmer for V Incandescent Lamps
Operating Instructions Incandescent Lamps 1. Safety instructions Attention: Electrical equipment must be installed and fitted only by qualified electricians and in observance of the current accident prevention
More informationRexroth IndraDrive Fc Compact, high-performance standard frequency converters
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Simply a better drive 2
More informationSeries CT7N Bimetallic Overload Relays
Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor
More informationIndoor Linear 80W Driver SI-C215280N2KR
Product Data Sheet Rev.00 2017. 2. 9 1# LED Driver Indoor Linear 80W Driver SI-C215280N2KR Constant Current LED Driver Features & Benefits Output Current Range: 1550mA Output Voltage Range: MAX 51 Vdc
More informationR&S ZN-Z85 Switch Matrix Specifications
R&S ZN-Z85 Switch Matrix Specifications Data Sheet Version 01.02 CONTENTS Definitions... 3 Block diagrams... 4 Specifications... 5 General features... 5 Performance data... 5 Remote control... 5 Switching
More informationTeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40
Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,
More informationwww.greenelectricalsupply.com MaxLite 6 & 8 Commercial Downlight Retrofit General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts,
More informationLXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O
Characteristics motion servo drive - Lexium 23 - single phase 200...255 V - 1 kw - I/O Main Range of product Product or component type Device short name Complementary Format of the drive Network number
More informationLED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White
Driver LCAI 38/75W TW lp Tunable White Product description 2-channel LED Driver with LI DT8 Output power: 38 W or 75 W Power input on standby < 0.3 W Nominal life-time up to 50,000 h 5-year guarantee Properties
More informationI r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100
DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection
More informationR&S ZVA-Zxx Millimeter-Wave Converters Specifications
R&S ZVA-Zxx Millimeter-Wave Converters Specifications Data Sheet Version 19.00 CONTENTS Definitions... 3 General information... 4 Specifications... 5 Test port... 5 Source input (RF IN)... 5 Local oscillator
More informationGamma instabus. Technical product information
Gamma instabus Technical product information Universal dimmer N 554D31, 4 x 300 VA / 1x 1000 VA, AC 230 V Universal dimmer N 554D31 Control of dimmable lamps, including LED without minimum load Output
More informationDescription Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100
DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective
More informationSafety Codes Council Conference Banff C Panel Discussion
Safety Codes Council Conference Banff 2014 90 C Panel Discussion Tim Driscoll OBIEC Consulting Ltd. George Morlidge Fluor Canada Ltd. Scott Basinger Eaton Canada René Leduc Marex Canada Limited Perspectives
More informationFile E64388 Vol. 1 Sec. 106 Page 1 Issued: and Report Revised:
File E64388 Vol. 1 Sec. 106 Page 1 Issued: 1993-11-08 and Report Revised: 2011-06-01 DESCRIPTION PRODUCT COVERED: USR; Component - Appliance Filter, Models FN261#W-Y-XX-ZZ, FN9260#W-Y-XX- ZZ, FN9263#W-Y-XX-ZZ,
More informationR&S ZN-Z154 Calibration Unit Specifications
ZN-Z154_dat-sw_en_3607-0481-22_v0101_cover.indd 1 Data Sheet 01.01 Test & Measurement R&S ZN-Z154 Calibration Unit Specifications 25.06.2014 10:27:09 CONTENTS Definitions... 3 Measurement range... 4 Effective
More informationTGL2209 SM 8 12 GHz 50 Watt VPIN Limiter
Product Overview The Qorvo is a high power, X-band GaAs VPIN limiter capable of protecting sensitive receive channel components against high power incident signals. The does not require DC bias, and achieves
More informationMultifunction Digital Timer
Multifunction Digital Timer 72 x72 mm Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationLED Driver Compact dimming
Driver CA 15W 180-350mA flexc PH-C SR ADV ADVACED series Product description Dimmable constant current ED Driver (SEV) Independent ED Driver with cable clamps Selectable output current between 180, 250
More informationLED control gear Compact fixed output
Driver LC 40W 900mA fixc SR SNC ESSENCE series Product description Independent fixed output LED Driver Constant current LED Driver Output current 900 ma Max. output power 39 W Nominal life-time up to 50,000
More informationPOWER FACTOR CORRECTION
Main Catalogue 2015 POWER FACTOR CORRECTION POWER QUALITY ENERGY MANAGEMENT FRAKO Leading-edge quality for reliable power supply networks FRAKO's mission is to provide solutions that are designed and
More informationHID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp
Product description Pulse packets for increased ignition energy (pulsecontrol technology) Flicker-free light Colour stability thanks to constant power No acoustic resonance Safety shutdown if a lamp is
More informationPanel-mounting thermostats, type series EM
Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting
More informationDLP600M 6+1 Relay Module for Heating and Cooling Plants
Product Sheet TH6.25 Thermostat Type DLP600M DLP600M 6+1 Relay Module for Heating and Cooling Plants The DLP 600 M is a relay module for activation of loads (namely thermal actuators or circulators) in
More informationGear Pump Units. For single-line lubrication systems
Gear Pump Units 1-1202-US For single-line lubrication systems MFE5-KW3-2 MFE5-BW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,
More informationMASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz
Mobile Communications MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO
More informationCeramic Disc Capacitors Safety Standard Approved Disc AC Capacitors
Ceramic Disc Capacitors EMI/RI Y1-VY1 EATURES D e = 3.0 mm max. T SH = 4.0 mm max. Complying with IEC 60384-14, 3rd edition High reliability Vertical (inline) kinked or straight leads Compliant to RoHS
More informationInstructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)
Satellite multiswitch Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16) EMP-CENTAURI is a registered trademark Dear Customer, Thank you for buying the EMP-Centauri
More informationTA48M025F,TA48M03F,TA48M033F TA48M0345F,TA48M04F,TA48M05F
TOSHIBA Bipolar Linear Integrated Silicon Monolithic TA48M025F,TA48M03F,TA48M033F TA48M0345F,TA48M04F,TA48M05F 2.5, 3, 3.3, 3.45, 4, 5 Three-Terminal Low Dropout oltage Regulator The TA48M**F series consists
More informationTRF STEP-DOWN TRANSFORMER USER MANUAL
TRF STEP-DOWN TRANSFORMER USER MANUA www.ventilation-system.com 2013 ! WARNING The present operation manual consisting of the technical details, operating instructions and technical specification applies
More informationQPC6222SR GENERAL PURPOSE DPDT TRANSFER SWITCH. Product Overview. Key Features. Functional Block Diagram. Applications. Ordering Information
Product Overview The is a dual-pole double-throw transfer switch designed for general purpose switching applications where RF port transfer (port swapping) control is needed. The low insertion loss along
More information1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control
IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and
More informationThis device is a lighting effect for professional use on stages, in discotheques, theatres, etc..
At first, thank you for purchasing QUADRO 24. For the sake of safety and regular operation of this projector, please read this manual carefully before using and operating it, lest incur any personal injury
More informationInstructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)
Satellite multiswitch Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-AP-12 (13/12) P.160-CP-12 (13/12) P.160-AP-16 (13/16) P.160-CP-16 (13/16) EMP-CENTAURI is a registered trademark Dear
More informationUSER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!
USER MANUAL DE-1 Police-light CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! For your own safety, please read this user manual carefully before you
More informationDocumentation. Magnetic Encoder System (MES) Version: Date:
Documentation Magnetic Encoder System (MES) Version: Date: 1.1 2016-02-26 Table of content Table of content 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Intended use... 5 1.3 Documentation
More informationCyclo Series. user manual. MartinArchitectural
Cyclo Series user manual MartinArchitectural Measurements are in millimeters 63 Cyclo 02 88 Cyclo 03 1000 81 1190 88 Cyclo 04 98 88 2002 Martin Professional A/S, Denmark. All rights reserved. No part of
More informationOperating Instructions
CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target
More informationAS09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional
More informationColour Explosion Proof Video Camera USER MANUAL VID-C
Colour Explosion Proof Video Camera USER MANUAL VID-C Part Number: MAN-0036-00 Rev 4 Copyright 2002 Net Safety Monitoring Inc. Printed in Canada This manual is provided for informational purposes only.
More informationOil/air cooler. Table of contents. Features. Applications. RE 50112/05.13 Replaces: Type KOL and KOLP
Oil/air cooler RE 50112/05.13 Replaces: 01.12 1/24 Type KOL and KOLP Component series 2X aximum flow 400 l/min [105 GP] H7131 Table of contents Contents Page Features, applications 1 Description, symbols
More informationCAMTO LTD. Arc detecting system DC/AC
CAMTO LTD Arc detecting system DC/AC Arc detecting system DC/AC The system is based on experience with arc protection since 1962. The system units are built into boxes that all fit on a 35 mm DIN-rail.
More informationMagnecraft Power Relays
Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These
More informationACTIVE IF SPLITTER/COMBINER UHP-IFS
ACTIVE IF SPLITTER/COMBINER UHP-IFS GENERAL DESCRIPTION AND INSTALLATION GUIDE DOCUMENT RELEASE 2 [UHP.IFS.2.EN] JUNE 2016 CONTENT Acronyms and Abbreviations... 4 Introduction... 5 Required level of qualification...
More informationTVAC20000 User manual
TVAC20000 User manual Version 01/2010 Original English user manual. Keep for future use. 10 Introduction Dear Customer, Thank you for purchasing this product. This product meets the requirements of the
More information