721N Spectrophotometer. Operating Manual

Size: px
Start display at page:

Download "721N Spectrophotometer. Operating Manual"

Transcription

1 721N Spectrophotometer Operating Manual

2 TABLE OF CONTENTS 1. APPLICATIONS AND FEATURES SPECIFICATIONS AND STANDARD ACCESSORIES PRODUCT APPEARANCE AND FUNCTION KEYS INSTALLATION INSTALLATION ENVIRONMENT CHECK-UP WHEN UNPACKING INSTALLATION OPERATIONS BASIC OPERATIONS Warming up Zero adjustment Adjust 100%T Wavelength measurement Change the groove position to get sample into optical path Change the scales PRACTICAL OPERATIONS Measure the transmittance of transparent materials Determine the transmittance curves of transparent materials Determine the transmittance of transparent solutions Do quantitative measurement with standard curve method Use the direct reading MAINTENANCE AND ERROR RECOGNITION DAILY MAINTENANCE Notice Inspect the instrument Replace the source lamp Clean the liquid storage container

3 6.2 CHECK THE FUNCTION OF MAIN DEVICE Check the wavelength range Check the transmittance repeatability Check fixed-point noise Check the wavelength repeatability IDENTIFYING AND HANDLING THE COMMON MALFUNCTIONS

4 1. Applications and Features 721N visible spectrophotometer, compact and easy-to-use spectrophotometric equipment, can be used to measure transmission, absorption and concentration direct-reading at wavelengths from 360nm to 1000nm. It can be widely applied to departments related to medical health, clinical examination, biochemistry, petro-chemistry, environmental monitoring and quality control as qualitative and quantitative analyses. The main features are the following: 4-digit LED display Reasonable structure with advanced optical system, using precision machining high-quality CT monochromator and sealed grating, the optical properties of which are superior to the traditional LITTROW monochromator, with obvious advantages in the indicators such as resolution, photometric accuracy, stray light and stability. And its size is smaller. Special precision pre-adjustment lamps and lamp holder fittings. Not necessary to re-adjust optical path for installation which is convenient for users without any professional maintenance skills. Precision-linkage cutoff filter system automatically switching to appropriate wavelength filters, further reducing stray light Sample cells made of special engineering plastics, resistant to solvent as well as strong acid/alkali, which enhances its anti-corrosion properties. Effusion dish and liquid storage container, which can be removed and cleaned, are mounted on the bottom to increase the service life. 4-position colorimetric cell shelf, with optional rectangular optical path colorimetric dish with diameter from 1 cm to 5cm. Automatic zero and 100%T adjustment Concentration factor setting and concentration direct-reading functions 3

5 2. Specifications and Standard Accessories 1. Optical system: diffraction grating C-T monochromator 2. Wavelength range:360nm~1000nm 3. Source lamp: halogen lamp 10W/8V 4. Wavelength accuracy: ±3.0nm 5. Wavelength repeatability: 1.5nm 6. Transmittance accuracy: ±0.8 %( ) (SRM930D) 7. Transmittance repeatability: 0.3 %( ) 8. Spectrum bandwidth: 6nm 9. Stray light: 1.0 %( ) (360nm, NaNO 2 ) 10. Display scale: (T):0.0~199.9% (A):-0.3~2.999 (F):1~9999 (C):0~ Power supply: 90~250V, 50/60Hz, 40W 12. Dimension: 350mm 300mm 220mm 13. Weight: net weight: 4kg; gross weight: 6kg 14. Basic set: 1. Main device: 1pc 2. Power cord: 1pc 3. Operating manual: 1pc 4. Product Quality Certificate: 1pc 5. Fuse (2A): 2pcs 6. 1cm rectangular colorimetric dish (glass): 4pcs 7. 1cm optical path colorimetric dish shelf: 1pc 8. Packing list: 1pc 15. Optional spare parts 1. Fuse (2A/3A) 2. Illuminant light components with pre-calibration lamp bracket 4

6 3. Rectangular colorimetric dish: 1cm, 2cm, 3cm, 5cm 4. 5cm optical path colorimetric dish shelf 5. Pr-Nd filters 6. Holmium trioxide filters 5

7 3. Product Appearance and Function Keys 1. /100% key: automatically adjusts 100%T when "transmittance lamp is bright (Press once again if the first press doesn't work); automatically adjusts absorbance 0 when "absorbance lamp lights (press once again if the first press doesn't work); increases concentration factor settings when "concentration factor lamp is bright. Press for 1 second, then the values increase rapidly, then press MODE to confirm set values automatically; increases concentration direct-reading settings when "direct-reading lamp lights. Press for one second, the values increase rapidly, and then press MODE to confirm set values automatically. 2. /0% key: automatically adjusts 100%T (range<10%t) when "transmittance lamp lights; *Don't use "absorbance" lamp when it is bright, otherwise it ll be overloaded; reduces concentration factor settings in the same way as for /100% when "concentration factor lamp lights reduces direct-reading settings in the same way as for /100% when "direct-reading method lamp lights. 3. FUNCTION key: is used as an extension functional key for presetting 4. MODE key: selects display scales 6

8 lamps lights up in the sequence of "transmittance, "absorbance, "concentration factor, and "direct-reading, press to start another circle of lightening lamps. 5. Display window 4-digit LED number Displays data and error information 6. "Transmittance lamp: displays transmittance data 7. "Absorbance lamp displays absorbance data 8. "Concentration factor lamp: displays concentration factor data 9. "Concentration direct-reading lamp: displays direct-reading data 10. Sample cell: tests samples 11. The pull rod of the groove shelf: changes the position of sample groove (4) 12. Wavelength display window: displays the wavelength 13. Wavelength regulation button: adjusts the wavelength 14. Power socket: connects the power cord 15. Main switch: ON/OFF power supply 7

9

10 4. Installation 4.1 Installation environment This instrument is suitable for analytical experiments under lab conditions, the following requirements are demanded due to the fact that it works with PC: Temperature: 5 ~35, relative humidity is less than 85% It is mounted on a steady working platform, free from vibration, direct sunlight, strong electromagnetic field interference, dust and corrosive gas Power voltage:90~250v Frequency:50/60Hz Clean the instrument surface with room temperature water, do not use cleaning solvents such as alcohol or acetone If the equipment is to be used on the spot, please use the original package while being moved. On-site working environment usually complies with the above requirements. Please make special orders if users have special requirements. 4.2 Check-up when unpacking Note: the instrument and computer are packed in paper cardboard boxes (wooden boxes are required for long-distance transportation) Please check the package before unpacking. If the package is incomplete or Collision traces are found, please contact the insurance and transportation department Open along the sealing tapes; carefully remove the main device and computer (please save the outer package for the later using). Check the main device's Standard and optional components according to the packing list. Contact the area sales or our company if there is any problem. 9

11 4.3 Installation Remove the fixing tapes which are for transportation, clean the surface, then check the power switch at the bottom of the device. Make sure voltage requirement is consist with the local power supply, then put the main device on a stable working station, keeping clearance more than 10 cm away from the wall. Connect power cord to the outlet at the lab. 10

12 5. Operations 5.1 Basic operations Warming up After the instrument is started, lamps and electric components need heat balance; therefore, measurement will be done in 30 minutes after it is warming up. For urgent usage, adjust 0%T or 100% any time Zero adjustment Purpose: adjusts both sides of the basic scale (along with 100%T adjustment), enter the correct testing module; Timing adjustment: after warming up, change measuring wavelength or having tested for a period; or before high precision measurement; Operation: open the sample cover (automatically shut the light valve) or shade the optical path with opaque materials in the sample cell, then press 0%, then zero is automatically adjusted Adjust 100%T Purpose: adjusts both sides of the basic scale (along with zero adjustment), and enters the correct measuring status; Timing adjustment: after warming up, change measuring wavelength or testing for a period or before high precision measuring (generally, do 100%T adjustment before zero adjustment as to make the automatic increase inside the device to the full reach); Operating: empty sample used as background is put into the light valve of the sample cell, shut the sample cover (automatically open the light valve), press 100% to automatically adjust 100%T (press once more if error occurs); Note: when adjusting 100%T, the automatic gain system re-adjustment may 11

13 influence 0%T. Check 0%T after adjustment. If there's any change, re-adjust 0% for once Wavelength measurement Use the only knob on the equipment to adjust the current measuring wavelength. The wavelength displays on the window to the left of the knob. Read the readings vertically. Note: this machine uses precision-linkage cutoff filters system, so when the knob rotates, there will be metal gratings. Low gratings at 360nm-1000nm are normal Change the groove position to get various samples into optical path. In the standard specification, the testing sample groove shelf has four positions. It can be controlled by the pull rod on the front of the device. Open the sample cell cover to observe the positions: the closest one to the user is 0, then 1, 2, 3 in sequence. The corresponding pull rod reaches 0 by pushing backward to the end, then pull 1, 2, 3 outward respectively. When the rod is at the right position, the user may feel it. Please push it a bit to make sure the position is right Change the scales This equipment has four scales: Transmittance: measures the transmittance features of transparent liquids and solids; Absorbance: uses as quantitative analysis with standard curve method or absolute absorption spectrometry; also used in kinetic tests; Concentration factors: sets concentration factors when direct reading with the concentration factor method; Concentration direct-reading: sets and reads with standard sample method to read directly; also directly reads the concentration when setting concentration factors; 12

14 Use MODE to adjust the scales, which displays with the lamps for transmittance, absorbance, concentration factor, direct-reading respectively, the initial status is transmittance, press to select by following the above procedures. 5.2 Practical operations Measure the transmittance of transparent materials Warm up Set wavelength Set the blank Set the scale to "transmittance Adjust 100%T Adjust zero Adjust 100%T Add samples Read data Determine the transmittance curves of transparent materials Within the required wavelength to be measured, repeatedly execute this method according to the required intervals in phase 1-8 of section 5.2.1, and write down the responding transmittance values on the paper, to display the transmittance curves. 13

15 5.2.3 Determine the transmittance of transparent solutions Warm up Set wavelength Set the blank Adjust 100%T 0%T Set the scale to absorbance Add the sample in the optical path Read data Do quantitative measurement with standard curve method 1 Get standard samples with known content 2 Prepare sample solutions and background solutions due to rules of analysis 3 Set wavelengths, blanks, zero adjustment, "absorbance", and read sample absorbance Repeat the above procedures and read the samples' absorbance Read the absorbance, draw the coordinate maps based on samples' known contents, and draw the best relative curves 6 Read the unknown samples' absorbance, and find

16 responding concentration on the curve Use the direct reading When the analysis procedure is stable and the basic standard curve passes the original point, users apply direct-reading to do quantitative measurement instead of through complex standard procedures. This method needs to prepare one sample solution with concentration at 2/3 of the quantitative range. The operation is as follows: 1 Measure the absorbance of standard samples phase Set the scale at concentration direct-reading Press or to set the reading at the known content(or 10 times of contents) 4 Add unknown sample solutions Read the displaying data, i.e. The content value(or 10 times of contents) Use concentration factors directly After the 3rd procedure, if the scale is set at concentration factor, the reading in the display window is the sample's concentration factor. Record the factor, then users read the figure without measuring it again until is switched off. The procedure is as follows: 1 Switch on, warm up, set the wavelength, set the background solution, adjust 0% and 100%T 2 Set the scale at concentration factor Press or to make the display value is the factor value 4 Set the scale at concentration direct-reading Set unknown sample solution

17 6 Read the displaying value, i.e. the concentration value 16

18 6. Maintenance and error recognition 6.1 Daily maintenance Notice Comply with requirements in 4.1 for daily use; Do not use organic solvents such as ethanol-ether to clean the equipment. Use a cover when it's not used; Clean the colorimetric dish with petroleum ether after using, and dry it with lens paper, is kept colorimetric dish box for the next use Inspect the instrument It is necessary to open the cover when it is required to check up the device, including the inner structures, optical path, and electric circuit, or to replace the source lamp. The procedures are as follows: Power off; Open the wavelength knob cover and remove the knob; Remove five M4 screws from the bottom of the equipment, open the cover to check the equipment (avoid touch the high-voltage part on the back of the device base) Replace the source lamp The equipment uses the long-service combining source lamp pre-corrected by the factory. Replace the damaged lamps based on the following steps: Open the upper cover (see 6.1.2); Remove the old illuminant light's parts: remove the connecting cable, 2 M4 screws on the lamp shelf, and other parts; Re-install the new illuminant parts according to the reverse order as that in ; observe the reflector at front, adjust the position of 17

19 the parts, and make sure the rectangle spots in the middle of the incident slit Clean the liquid storage container Lift the equipment up a little, and move the front end out of the desk; Take out the container on the bottom (beware of liquids flowing out during this procedure); Dump the liquid, clean the container with water and dry it; Mount the container back to the original place; Put the equipment back to the original place. 6.2 Check the function of main device After the equipment finishes testing and maintenance, use the following to check to make sure the equipment has the standards Check the wavelength range Switch on the host and pre-heat for 30 min, the mode is on transmittance ; Turn the wavelength knob to both sides of the wavelength range, press 100%, 100%T will be achieved. Open the sample cell door, 0% can adjust to 0%T Check the transmittance repeatability Set the host's wavelength to 550nm, equipment to 0%T and 100%T Set the transmittance to 40%T and check the display value around the samples which are evenly absorbed nearby successively for three times (i.e. neutral filters). The maximal difference should be between±0.3%t Check fixed-point noise Set the wavelength to 550nm, and adjust to 0%T and 100%T. 18

20 Set the scale to absorbance Observe the data in the window, which should be within the range of 0.002A Check the wavelength repeatability Set the scale to transmittance Use the (Pr-Nd) filters (optional accessories, provided by ordinary companies) as samples Regard air as blank, adjust the equipment to 0%T and 100%T, add the sample into the optical path, read the responding wavelength values to standard peak value among 520nm~540nm Repeat three times, the wavelength reading errors should be 1.5nm. 6.3 Identifying and handling the common malfunctions Malfunctions Causes solutions 1) The equipment is powered on, but is not on 2) Instable data display 1. Not connected to the power 2. Fuses broken 3. Connectors loose 1. Not enough pre-heating time 2. Unstable AC power 3. Drastic vibration around the working environment 4. Bad plug-in connections 1. A Check the plug, should be well connected between 90~250V B Check if the power cable breaks C Check if the power plug breaks 2. Replace fuses 3. Re-plug plug-ins 1. Warm up for 30 mins 2. Maintain the power at 90~ 250V without sudden change 3. Change working environment 4. Open the cover and re-plug all plug-ins 19

21 3) Energy not 1. Illuminant light not light 1. Broken illuminant light to be measured 2. The light valve not open changed, or no voltage output 3. The colorimetric ware 2. Check if the light valve works completely cover the light 4. No signal output 3. Put in at the right position 4. Receiver broken to be changed, or not plugged in, or back contact 4) Cannot adjust 1. Not enough light energy 1. Select the right gain key; to 100%T 2. Colorimetric dish not in position check the light from the illuminant light in the incident slit; low light voltage adjust higher 2. Adjust it to the right position 5) Abnormal 1. Wrong solutions to the 1. Dealt with properly photometry samples 2. Reduce matching errors 2. Colorimetric dish not 3. Check with (Pr-Nd) glass and match adjust wavelength 3. Big wavelength errors 6) Err3 displays 1. Wrong operation 1. Power off then on again 20

Orbit TM DIGITAL SHAKERS

Orbit TM DIGITAL SHAKERS Orbit TM DIGITAL SHAKERS INSTRUCTION MANUAL Models P2, P4, M60, 300, 1000, 1900 Labnet International PO Box 841 Woodbridge, NJ 07095 Phone: 732 417-0700 Fax: 732 417-1750 email: labnet@labnetlink.com 2

More information

DH551C/DH550C/DL550C Double Sided Display User Manual

DH551C/DH550C/DL550C Double Sided Display User Manual DH551C/DH550C/DL550C Double Sided Display User Manual Disclaimer BenQ Corporation makes no representations or warranties, either expressed or implied, with respect to the contents of this document. BenQ

More information

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE ? 8 LCD Screen? 10.4 LCD Screen LCD Zoom Microscope Instruction Manual Please read the Instruction Manual carefully before installation and keep it for future

More information

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

ALO 030 MKII. 30 Watt DMX LED scanner. User manual ALO 030 MKII 30 Watt DMX LED scanner User manual Safety instructions WARNING! Always keep this device away from moisture and rain! Hazardous electrical shocks may occur! WARNING! Only connect this device

More information

LITE-ON TECHNOLOGY CORPORATION

LITE-ON TECHNOLOGY CORPORATION Features * Lead (Pb) free product RoHS compliant. * Low power consumption. * High efficiency. * Versatile mounting on p.c. board or panel. * I.C. compatible/low current requirement. * Popular T-1 diameter.

More information

Cylindrical Photoelectric Sensor CY-100 SERIES

Cylindrical Photoelectric Sensor CY-100 SERIES Cylindrical Photoelectric Sensor CY-00 SERIES Listing (2 m cable length type only) Features Wide product range Shape: Standard type Side view type Connector: 2 m cable length type M2 plug-in connector

More information

Colorimeters and UV/Visible Spectrophotometers. from

Colorimeters and UV/Visible Spectrophotometers. from Colorimeters and UV/Visible Spectrophotometers from WPA, Biochrom Ltd and UV/Visible Spectrophotometry WPA Ltd was acquired by Biochrom Ltd in 2002 because their range of colorimeters and innovative spectrophotometers

More information

Achat 115 Sub A active subwoofer. user manual

Achat 115 Sub A active subwoofer. user manual Achat 115 Sub A active subwoofer user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Deutschland Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

LED Thunder S-150 Code 1097

LED Thunder S-150 Code 1097 LED Thunder S-150 Code 1097 User Manual 1 1 SAFETY INSTRUCTIONS This device has left the factory in perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely

More information

TABLE OF CONTENTS Important Safety Instructions Package Content Setting Up the Display Trouble shooting Specifications Product Dimensions

TABLE OF CONTENTS Important Safety Instructions Package Content Setting Up the Display Trouble shooting Specifications Product Dimensions TABLE OF CONTENTS Important Safety Instructions...1 1.1 Safety precautions and maintenance....1 1.2 Use.......4 1.3 Installation Notes.......7 Package Content...9 2.1 Unpacking...9 2.2 Accessories......10

More information

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Model DT-311J And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL 1. GENERAL The DT-311J DIGITAL

More information

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs User Manual 360W LED Moving Zoom 36pcs10W 4 in 1 RGBW LEDs KEEP THIS MANUAL FOR FUTURE NEEDS 1. Dispacking Thank you for choosing our moving head. For your own safety, please read this manual before installing

More information

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E USER MANUAL 27 Full HD Widescreen LED Monitor L270E TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any MCTRL4K Independent Controller Product Version: Document Number: V1.0.3 NS110100428 Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced,

More information

DMX LED light effect with 4 lenses

DMX LED light effect with 4 lenses DMX LED light effect with 4 lenses User manual 1 Safety precautions WARNING: This unit may cause serious injury to the eyes when used incorrectly. It is therefore strongly advised to read this user manual

More information

Fiber Optic. Foreword. Special Tips:

Fiber Optic. Foreword. Special Tips: Foreword This manual applies to 1310nm AM direct modulated optical transmitter with SNMP network management interface. It mainly describes the performance characteristics, technical parameters, installation

More information

MS2540 Current Loop Receiver with RS485 Communication

MS2540 Current Loop Receiver with RS485 Communication MS2540 Current Loop Receiver with RS485 Communication User Manual Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358 4202 Fax:

More information

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

USER MANUAL. 28 4K Ultra HD Monitor L28TN4K USER MANUAL 28" 4K Ultra HD Monitor L28TN4K TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety Info &

More information

DSP 18 Sub active subwoofer. user manual

DSP 18 Sub active subwoofer. user manual DSP 18 Sub active subwoofer user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 05.11.2018,

More information

Buhl Industries VP-30 Visual Presenter. USER MANUAL Version

Buhl Industries VP-30 Visual Presenter. USER MANUAL Version Buhl Industries VP-30 Visual Presenter USER MANUAL Version 8-5-08 NOTICES: PLEASE READ CAREFULLY BEFORE USE Use the visual presenter under rated electric conditions with included power supply only Do not

More information

Through Hole Lamp Product Data Sheet LTW-2S3D7 Spec No.: DS Effective Date: 10/06/2012 LITE-ON DCC RELEASE

Through Hole Lamp Product Data Sheet LTW-2S3D7 Spec No.: DS Effective Date: 10/06/2012 LITE-ON DCC RELEASE Through Hole Lamp Product Data Sheet LTW-2S3D7 Spec No.: DS20-2005-014 Effective Date: 10/06/2012 Revision: C LITE-ON DCC RELEASE BNS-OD-FC001/A4 LITE-ON Technology Corp. / Optoelectronics No.90,Chien

More information

Through Hole Lamp Product Data Sheet LTW-42NDP4-HF Spec No.: DS Effective Date: 08/23/2011 LITE-ON DCC RELEASE

Through Hole Lamp Product Data Sheet LTW-42NDP4-HF Spec No.: DS Effective Date: 08/23/2011 LITE-ON DCC RELEASE Through Hole Lamp Product Data Sheet LTW-42NDP4-HF Spec No.: DS20-2011-0111 Effective Date: 08/23/2011 Revision: A LITE-ON DCC RELEASE BNS-OD-FC001/A4 LITE-ON Technology Corp. / Optoelectronics No.90,Chien

More information

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701 OWNER S MANUAL PW MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701 ANY CHANGES OR MODIFICATIONS IN CONSTRUCTION OF THIS UNIT DEVICE WHICH IS NOT APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIACE COULD VOID

More information

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS USER MANUAL 27 Full HD Widescreen LED Monitor L27ADS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

USER MANUAL. 27 2K QHD LED Monitor L27HAS2K USER MANUAL 27" 2K QHD LED Monitor L27HAS2K TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Troubleshooting 6 Safety Info & FCC warning 1 GETTING

More information

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer Fluorescence Spectrophotometer www.labocon.com NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. FLUORESCENCE SPECTROPHOTOMETER LFS-100

More information

SE-SMD0603-PW65 SMD 0603 purweiss, wasserklar

SE-SMD0603-PW65 SMD 0603 purweiss, wasserklar 1. Features: Lighting Color: Ultra Bright Pure White Lens Color: Water Clear Flat Mold 2. (Package Dimensions): Notes: All dimensions are in millimeters. Tolerance is ± 0.10mm unless otherwise noted 03.05.2017

More information

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating

LED Spot Light User Manual Model LS90 Big Dipper Laser Science And Technology Co., Ltd Please read this manual carefully before operating LED Spot Light User Manual Model:LS90 Big Dipper Laser Science And Technology Co., Ltd REV: 1.01 Please read this manual carefully before operating Warnings: Please check the package whether any damage

More information

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR 28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR INSTRUCTION MANUAL Please read this manual thoroughly before use, and keep it handy for future reference. TABLE OF CONTENTS 1, General information...

More information

Optical Receiver Manual. Transmitter OP-OR112R JⅢ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2)

Optical Receiver Manual. Transmitter OP-OR112R JⅢ. Shenzhen Optostar Optoelectronics Co., Ltd (Version 2) Optical Receiver Manual Transmitter OP-OR112R JⅢ Shenzhen Optostar Optoelectronics Co., Ltd 2016. 7(Version 2) 1. Summary OP-OR112RJⅢ optical receiver is our latest 1GHz FTTB optical receiver. With wide

More information

User's Guide to the PROLITE-30B

User's Guide to the PROLITE-30B User's Guide to the PROLITE-30B Optical Fiber Identifier v1.0 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 0 MI2027 (02/12/2014)

More information

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras INSTALLATION MANUAL FT-FOTR-8VD-ST-S 8-Channel Digital Duplex Baseband Transmitter and Receiver With Reverse Transmission for PTZ Cameras v1.0 4/5/11 1 PACKAGE CONTENTS This package contains: One each

More information

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S INSTALLATION MANUAL FT-FOTR-1VDE-ST-S 1-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission & Ethernet Transmission v1.0 4/5/11 1 PACKAGE CONTENTS This package

More information

DCL9AW. User Manual. English

DCL9AW. User Manual. English DCL9AW User Manual English PRECAUTIONS Information for users applicable in European Union countries 1 Information for users applicable in United States of America 1 Installation 1 Power connection 1 Maintenance

More information

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Model KBF P 240 Humidity test chambers with ICH-compliant light source Model KBF P 240 Humidity test chambers with ICH-compliant light source The KBF P humidity test chamber, equipped with ICH-compliant light source, is an expert when it comes to photostability tests and

More information

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China ORLAND SCAN PR-1201 This product manual contains important information about the safe installation and use of this projector. Please read and follow these instructions carefully and keep this manual in

More information

User Manual MagniLink Mira

User Manual MagniLink Mira User Manual MagniLink Mira LVI Low Vision International Verkstadsgatan 5 Tel: +46 470 727700 E-mail: info@lvi.se 352 46 Växjö SWEDEN Fax: +46 470 727725 Internet: www.lvi.se CONTENTS 1. GENERAL INFORMATION...

More information

SmartCrystal Cinema Neo

SmartCrystal Cinema Neo Model VPSP-11100 www.volfoni.com 1 SUMMARY SUMMARY... 2 I. PRODUCT OVERVIEW... 3 II. REQUIREMENTS... 3 III. SMARTCRYSTAL CINEMA NEO FEATURES... 5 A. General specifications... 5 B. Technical specifications...

More information

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor Model CB 160 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor The BINDER CB series CO 2 incubator is the premium class among the CO 2 incubators. It is suitable for all sensitive

More information

IKA Analytical line Calorimeters C 2000

IKA Analytical line Calorimeters C 2000 Calorimeters C 2000 Analytical line Calorimeters 140 C 2000 basic,, C 2000 basic high pressure and high pressure The C 2000 basic and calorimeters are the newest systems from IKA for determining gross

More information

USER MANUAL Full HD Widescreen LED Monitor L215ADS

USER MANUAL Full HD Widescreen LED Monitor L215ADS USER MANUAL 21.5 Full HD Widescreen LED Monitor L215ADS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! USER MANUAL DE-1 Police-light CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! For your own safety, please read this user manual carefully before you

More information

USER MANUAL Full HD Widescreen LED Monitor L215IPS

USER MANUAL Full HD Widescreen LED Monitor L215IPS USER MANUAL 21.5 Full HD Widescreen LED Monitor L215IPS TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

28 4K LED monitor. User Manual M284K

28 4K LED monitor. User Manual M284K 28 4K LED monitor User Manual M284K CONTENTS Safety Information... 2 What s included..... 4 Getting Started....... 8 Troubleshooting.... 14 Specification.... 15 2 of 15 SAFETY INFORMATION Read these instructions

More information

USER MANUAL Full HD Widescreen LED Monitor L236VA

USER MANUAL Full HD Widescreen LED Monitor L236VA USER MANUAL 23.6 Full HD Widescreen LED Monitor L236VA TABLE OF CONTENTS 1 Getting Started 2 Control Panel/ Back Panel 3 On Screen Display 4 Technical Specs 5 Care & Maintenance 6 Troubleshooting 7 Safety

More information

Model: S-4904T/R. Wireless HD Transmission System. User Manual. Please read this User Manual throughout before using.

Model: S-4904T/R. Wireless HD Transmission System. User Manual. Please read this User Manual throughout before using. Model: S-4904T/R Wireless HD Transmission System User Manual Please read this User Manual throughout before using. Preface Congratulations on your purchase of this product. Please read this user manual

More information

Octagon Theater CW/WW/A 20 6W LED PAR. user manual

Octagon Theater CW/WW/A 20 6W LED PAR. user manual Octagon Theater CW/WW/A 20 6W LED PAR user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

Through Hole Lamp Product Data Sheet LTW-1KHDS5Z Spec No.: DS Effective Date: 10/19/2012 LITE-ON DCC RELEASE

Through Hole Lamp Product Data Sheet LTW-1KHDS5Z Spec No.: DS Effective Date: 10/19/2012 LITE-ON DCC RELEASE Through Hole Lamp Product Data Sheet LTW-1KHDS5Z Spec No.: DS20-2012-0148 Effective Date: 10/19/2012 Revision: - LITE-ON DCC RELEASE BNS-OD-FC001/A4 LITE-ON Technology Corp. / Optoelectronics No.90,Chien

More information

SquareLED - Aura Bar & Matrix Beam Light 100

SquareLED - Aura Bar & Matrix Beam Light 100 SquareLED - Aura Bar & Matrix Beam Light 100 1. SAFETY INSTRUCTIONS Please read these instructions carefully they include the important information about the installation usage and maintenance of this

More information

RIPPLE TANK - projection, with strobe & kit

RIPPLE TANK - projection, with strobe & kit RIPPLE TANK - projection, with strobe & kit DESCRIPTION: Cat: SW3440-001 projection type with stroboscope, rippler & kit. The images created by IEC Ripple Tank Projection type are viewed from the side

More information

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD Document No:10103701 PAGE 2 C O N T E N T S 1. TECHNICAL SUMMARY...4 1.1 BRIEF DESCRIPTION...4 1.2 TECHNICAL

More information

MEISHU Phono INTEGRATED AMPLIFIER OWNER S INFORMATION

MEISHU Phono INTEGRATED AMPLIFIER OWNER S INFORMATION ! MEISHU Phono INTEGRATED AMPLIFIER OWNER S INFORMATION CONTENTS 1) IMPORTANT SAFETY INFORMATION 2) CE DECLARATION OF CONFORMITY DISPOSAL POWER REQUIREMENTS 3) INTRODUCTION 4) OVERVIEW UNPACKING AND INSTALLATION

More information

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One

Fixture One XLR Signal Cable One Omega Clamp - Two Safety Chain One User Manual - One TABLE OF CONTENTS 1. INTRODUCTION AND UNPACKING 1 2. SAFTEY INSTRUCTIONS 1-2 3. OPERATION INSTRUCTIONS 2-3 4. MOUNTING AND INSTALLATION 3-4 5. DMX-512 CONTROL CONNECTIONS 4-5 6. MENU NAVIGATION 5 7. PHOTOMETRIC

More information

User Manual. Please check the local Laser assignments in your country before starting the Laser Show!!!

User Manual. Please check the local Laser assignments in your country before starting the Laser Show!!! User Manual Thank you for using the Stairville DJLase series laser projector. For the sake of safety and better operation of this projector, please read this manual carefully before use and operate the

More information

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Please read the user manual before operation. PAGE 1 Content 1. Company Profile... 3 2. Product Introduction... 3 3. Operation Instruction...

More information

User Manual MODEL: KKW700V. Non-Touch True Display LCD Monitor. Installation Guide. 7 True Display LCD Monitor (VGA Interface)

User Manual MODEL: KKW700V. Non-Touch True Display LCD Monitor. Installation Guide. 7 True Display LCD Monitor (VGA Interface) Non-Touch True Display LCD Monitor User Manual Installation Guide 7 True Display LCD Monitor (VGA Interface) MODEL: KKW700V i-tech Company LLC TOLL FREE: (888) 483-2418 EMAIL: info@itechlcd.com WEB: www.itechlcd.com

More information

SMART CINEMAHORIZONTAL. User Guide VPSP Projector side. model. Notice SmartCrystal Cinema MUV V1R0

SMART CINEMAHORIZONTAL. User Guide VPSP Projector side. model. Notice SmartCrystal Cinema MUV V1R0 SMART User Guide CINEMAHORIZONTAL Projector side Notice SmartCrystal Cinema MUV130054-V1R0 model VPSP-05000 ENGLISH SUMMARY Content Page 1. PRODUCT OVERVIEW 3. 2. REQUIREMENTS 3. 3. SmartCrystal Cinema

More information

Manual placement system MPL3100. for BGA, CSP and Fine-Pitch components

Manual placement system MPL3100. for BGA, CSP and Fine-Pitch components Manual placement system MPL3100 for BGA, CSP and Fine-Pitch components Part No: MPL3100BA1.0e Issue Date: 02/2001 You have opted for an ESSEMTEC MPL3100 pick and place system. We thank you for this decision

More information

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

USER MANUAL. 22 Class Slim HD Widescreen Monitor L215DS USER MANUAL 22" Class Slim HD Widescreen Monitor L215DS TABLE OF CONTENTS 1 Getting Started Package Includes Installation 2 Control Panel / Back Panel Control Panel Back Panel 3 On Screen Display 4 Technical

More information

4K LED MONITOR 430LED4K & 550LED4K INSTRUCTION MANUAL. Please read this manual thoroughly before use, and keep it handy for future reference.

4K LED MONITOR 430LED4K & 550LED4K INSTRUCTION MANUAL. Please read this manual thoroughly before use, and keep it handy for future reference. 4K LED MONITOR 430LED4K & 550LED4K INSTRUCTION MANUAL Please read this manual thoroughly before use, and keep it handy for future reference. CONTENTS 1. GENERAL INFORMATION...3 2. 3. 1.1. 1.2. 1.3. 2.1.

More information

FiberLink 7142 Series

FiberLink 7142 Series MANUAL FiberLink 7142 Series 4 Channels of Composite Video and 8 Channels of Audio over one single mode or multimode fiber Installation and Operations Manual WWW.ARTEL.COM FibeLink 7142 Series Contents

More information

K Service Source. Apple High-Res Monochrome Monitor

K Service Source. Apple High-Res Monochrome Monitor K Service Source Apple High-Res Monochrome Monitor K Service Source Specifications Apple High-Resolution Monochrome Monitor Specifications Characteristics - 1 Characteristics Picture Tube 12-in. diagonal

More information

Video Digital Optical Converter

Video Digital Optical Converter Video Digital Optical Converter Model : W-VD1 AD Model : W-VD2 AD Model : W-VD4 AD Model : W-VD8 AD Video Digital Optical Converter adopt the advanced international digital video and optical fiber transmission

More information

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor The BINDER CB series CO 2 incubator is the premium class among the CO 2 incubators. It is suitable for all sensitive

More information

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division SPECIFICATION FIBER OPTIC SPLICE CLOSURE Model Spec. No. Distribution Depts. VSOF-BS403A VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division Sales Division Management Division Revision 10. 07 (Rev.4)

More information

POL-200 Semiautomatic Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD

POL-200 Semiautomatic Polarimeter. Instruction Manual BANTE INSTRUMENTS CO., LTD POL-200 Semiautomatic Polarimeter Instruction Manual BANTE INSTRUMENTS CO., LTD POL-200 Semiautomatic Polarimeter 1 Introduction Thank you for selecting the POL-200 semiautomatic polarimeter. This manual

More information

COLOR TFT LCD MONITOR. Manual

COLOR TFT LCD MONITOR. Manual COLOR TFT LCD MONITOR Manual DEAR CUSTOMERS Thank you for purchasing the liquid crystal display monitor. This product employs new integrate circuits and high quality TFT LCD modules. It is putting out

More information

Introduction...2. Features...2 Safety Precautions...2. Installation...4

Introduction...2. Features...2 Safety Precautions...2. Installation...4 PE1900 Contents Introduction...2 Features...2 Safety Precautions...2 Installation...4 Unpacking the Display...4 Locations and Functions of Controls...4 Connections...5 Using Your Display...7 Turning the

More information

110LP MOON Series. Phono Preamplifier. Owner s Manual

110LP MOON Series. Phono Preamplifier. Owner s Manual Phono Preamplifier Owner s Manual Owner s Manual I Table of Contents Introduction 4 Unpacking 5 Installation & Placement 5 Circuit Board Layout s 6 Internal Adjustments 7 Rear Panel Connections 8 Operating

More information

K Service Source. Apple High-Res Monochrome Monitor

K Service Source. Apple High-Res Monochrome Monitor K Service Source Apple High-Res Monochrome Monitor K Service Source Specifications Apple High-Resolution Monochrome Monitor Specifications Characteristics - 1 Characteristics Picture Tube 12-in. diagonal

More information

Model KT 53 Cooling incubators with thermoelectric cooling

Model KT 53 Cooling incubators with thermoelectric cooling Model KT 53 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the

More information

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta BEAM MOVING HEAD YODN Lamp W R MOVING HEAD Brightness / Stability This product manual contains important information about the safe installation and use of this projector. Please read and follow these

More information

Package Contents Connections and Controls... 5 Front of the active Subwoofer... 5 Rear of the active Subwoofer... 6

Package Contents Connections and Controls... 5 Front of the active Subwoofer... 5 Rear of the active Subwoofer... 6 Table of Contents: Safety and Service... 2 Operational Safety... 2 Location... 2 Ambient Temperature... 3 Electromagnetic Compliance... 3 Service... 4 Cleaning... 4 Disposal... 4 Package Contents... 4

More information

Model KT 115 Cooling incubators with thermoelectric cooling

Model KT 115 Cooling incubators with thermoelectric cooling Model KT 115 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the

More information

DIGITAL STROBOSCOPE OPERATION MANUAL. Model : DT-2239A

DIGITAL STROBOSCOPE OPERATION MANUAL. Model : DT-2239A DIGITAL STROBOSCOPE Model : DT-2239A Your purchase of this DIGITAL STROBOSCOPE marks a step forward for you into the field of precision measurement. Although this STROBOSCOPE is a complex and delicate

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION (FIBER OPTIC SPLICE CLOSURE) Model Spec. No. Distribution Depts. VSOF-BS403A SJP-0609-403A-01A/SD Quality Assurance Team Manufacturing Division Sales Division Management Division

More information

XCOM1002JE (8602JE) Optical Receiver Manual

XCOM1002JE (8602JE) Optical Receiver Manual XCOM1002JE (8602JE) Optical Receiver Manual - 2 - 1. Product Summary XCOM1002JE (8602JE) outdoor optical receiver is our latest 1GHz optical receiver. With wide range receiving optical power, high output

More information

User Manual. Adjustable Speed Vortex. Fixed Speed Vortex

User Manual. Adjustable Speed Vortex. Fixed Speed Vortex User Manual MX-S MX-F Adjustable Speed Vortex Fixed Speed Vortex Please read the User Manual carefully before use, and follow all operating and safety instructions! Technical specifications and outline

More information

INFORMATION TO THE USER

INFORMATION TO THE USER U.S.FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT INFORMATION TO THE USER NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device

More information

INSTALLATION MANUAL. ST-CVTSD520-WSD-W Smoke Detector Covert Camera. v1.2 8/11/11 1

INSTALLATION MANUAL. ST-CVTSD520-WSD-W Smoke Detector Covert Camera. v1.2 8/11/11 1 INSTALLATION MANUAL ST-CVTSD520-WSD-W Smoke Detector Covert Camera v1.2 8/11/11 1 PACKAGE CONTENTS This package contains: One ST-CVTSD520-WSD-W smoke detector covert camera One installation manual Mounting

More information

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Model KT 53 Refrigerated incubators with thermoelectric refrigeration Model KT 53 Refrigerated incubators with thermoelectric refrigeration The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The refrigerated incubators

More information

QuickSpecs. HP V19b 18.5-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. OK. 1. Power connector 3. Security lock slot 2.

QuickSpecs. HP V19b 18.5-inch Monitor. Overview. 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. OK. 1. Power connector 3. Security lock slot 2. Overview 1. Menu 3. Plus ( + ) 5. Power 2. Minus ( - ) 4. OK 1. Power connector 3. Security lock slot 2. VGA Brazil Version 1 April 20, 2018 Page 1 Model: 2XM32AA Panel Type 18.5-inch TN Viewable Image

More information

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any MRV366 Receiving Card Document Version: Document Number: V1.0.1 NS110100658 Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted

More information

BEAM 200. User Manual

BEAM 200. User Manual BEAM 200 User Manual Catalogue 1 Open-package inspection ----------------------------------------------------------------------page2 2 Attentions-----------------------------------------------------------------------------------------page2

More information

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any Receiving Card MRV328 Document Version: Document Number: V1.0.0 NS110100409 Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted

More information

Projectors EFFORTS FOR PROJECTOR QUALITY

Projectors EFFORTS FOR PROJECTOR QUALITY Projectors EFFORTS FOR PROJECTOR QUALITY Projectors require a strong power of expression to build effective communication in business. We envision all circumstances from a wide range of installation methods

More information

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0091-003 TNP500 Universal Tilt N Plug Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the TNP100 Tilt N Plug Interconnect Box is greatly appreciated. We are sure you

More information

monolight Q-400 INSTRUCTIONS INSTRUCTIONS

monolight Q-400 INSTRUCTIONS INSTRUCTIONS monolight Q-400 INSTRUCTIONS INSTRUCTIONS Introduction Congratulations on your purchase of the Angler Silver 18 softbox! The Angler Q-400 Monolight can be used for everything from professional wedding

More information

LED Spot 300W. Please read this user manual before your operation

LED Spot 300W. Please read this user manual before your operation LED Spot 300W Please read this user manual before your operation 1. Introduction 2. General Guideline 3. Safety Instructions 4. Cleaning and Maintenance 5. Technical Parameters 6. DMX Channels 7. Remark

More information

Outdoor IR Audio Camera

Outdoor IR Audio Camera Outdoor IR Audio Camera User s Guide CM-S22326BW-AD SAFETY PRECAUTIONS WARNING 1. Be sure to use only the standard adapter that is specified in the specification sheet. Using any other adapter could cause

More information

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement A worldwide leader in precision measurement solutions MTI-2100 FOTONIC SENSOR High resolution, non-contact measurement of vibration and displacement MTI-2100 Fotonic TM Sensor Unmatched Resolution and

More information

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010 Operating instructions Retro-reflective sensor OJ50xx laser 70481 / 00 05 / 010 Contents 1 Preliminary note3 1.1 Symbols used 3 Safety instructions 3 4 Installation 4 4.1 Installation of the supplied mounting

More information

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL LED Beam Moving Head TWIST-150LED Order No. 38.7970 INSTRUCTION MANUAL MONACOR INTERNATIONAL GmbH & Co. KG Zum Falsch 36 28307 Bremen Germany www.monacor.com 01.30.11.2016 ELECTRONICS FOR SPECIALISTS ELECTRONICS

More information

T3316 IP QAM Modulator User Manual

T3316 IP QAM Modulator User Manual T3316 IP QAM Modulator User Manual SW Version: 1.02 HW version: 0.70.0.0 Web NMS version: 1.02 Intended Audience About This Manual This user manual has been written to help people who have to use, to integrate

More information

CM-S38901SV TVL IR Long Range camera

CM-S38901SV TVL IR Long Range camera 5 40 TVL IR Long Range camera User s Guide CM-S38901SV SAFETY PRECAUTIONS WARNING 1. Be sure to use only the standard adapter that is specified in the specification sheet. Using any other adapter could

More information

FLEXIBLE SERIES DA LR WW LENTUS

FLEXIBLE SERIES DA LR WW LENTUS Technical Information is an ideal solution which can be used easily for limited areas or thin spaces because of its minimalist design of 1cm, flexible body structure and sticky band feature found behind..

More information

Mechanical flow switch for On/Off control

Mechanical flow switch for On/Off control Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...

More information

Ambient Temperature...3 Electromagnetic Compliance...3

Ambient Temperature...3 Electromagnetic Compliance...3 TABLE OF CONTENTS: SAFETY AND SERVICE... 2 Operational Safety... 2 Location... 2 Ambient Temperature...3 Electromagnetic Compliance...3 Service... 3 Cleaning... 3 Package Contents... 4 Specifications...

More information

22" Touchscreen LED Monitor USER'S GUIDE

22 Touchscreen LED Monitor USER'S GUIDE 22" Touchscreen LED Monitor USER'S GUIDE Content Operation Instructions...1 Unpacking Instructions...2 Safety Precautions...2 Front View of the Product...3 Rear View of the Product...4 Quick Installation...5

More information

RQflex 10. Manual English

RQflex 10. Manual English RQflex 10 Manual English Contents 1 Introduction 3 2 Description of the instrument 5 display, keys 6 technical data 8 3 Setting up the instrument 9 insertion of batteries 10 setting the time and date 11

More information