DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.
|
|
- Cory York
- 5 years ago
- Views:
Transcription
1 DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from mbar up to bar Output signals -wire: ma -wire: 0 0 ma / 0 0 V others on request Special characteristics perfect thermal behaviour excellent long term stability pressure port G /" flush from 00 mbar on Optional versions IS-version Ex ia = intrinsically safe for gases and dusts SIL according to IEC 6508 / IEC 65 pressure sensor welded specific versions The pressure transmitter DMP can be used in all industrial areas when the medium is compatible with stainless steel.4404 (6 L) or.445 (6 L). Additional are different elastomer seals as well as a helium tested welded version available. The modulare concept of the device allows to combine different stainless steel sensors and electronic modules with a variety of electrical and mechanical versions. Thus a diversity of variations is created, meeting almost all requirements in industrial applications. Preferred areas of use are Plant and Machine Engineering Environmental Engineering (water - sewage - recycling) Energy Industry DMP TRI-MATIC AG, CH - 6 Hünenberg Tel Fax TRI-MATIC SA, CH Yverdon-les-Bains Tél Fax TM_D_0engl.doc / 0 All information in this document can be changed without notice Seite / Page
2 DMP Input pressure range gauge / abs. [bar] Overpressure [bar] Burst pressure [bar] gauge / abs. [bar] Overpressure [bar] Burst pressure [bar] Vacuum resistance P N bar: unlimited vacuum resistance P N < bar: on request Output signal / Supply Standard -wire: ma / V S = 8... V DC Option IS-protection -wire: ma / V S = V DC Options -wire -wire: ma / V S = V DC V / V S = V DC Performance Accuracy standard: nominal pressure < 0.4 bar: ± 0.5 % FSO nominal pressure 0.4 bar: ± 0.5 % FSO option : nominal pressure 0.4 bar: ± 0.5 % FSO option : for all nominal pressure: ± 0. % FSO Permissible load current -wire: R max = [(V S V S min) / 0.0] Ω current -wire: R max = 500 Ω voltage -wire: R min = 0 kω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year at reference conditions Response time -wire: 0 msec -wire: msec accuracy according to IEC limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) P N [bar] - 0 < Tolerance band [% FSO] ± 0.75 ± ± 0.75 in compensated range [ C] Permissible temperatures Permissible temperatures medium: C electronics / environment: C storage: C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS ( Hz) according to DIN EN Shock 500 g / msec according to DIN EN Materials Pressure port stainless steel.4404 (6 L) Housing stainless steel.4404 (6 L) Option compact field housing stainless steel.405 (0), cable gland brass, nickel plated others on request Seals (media wetted) standard: FKM options: EPDM NBR welded version others on request Diaphragm stainless steel.445 (6 L) Media wetted parts pressure port, seals, diaphragm welded version only with pressure ports according to EN 87 Explosion protection (only for 4 0 ma / -wire) Approval DX9-DMP IBExU 0 ATEX 068 X zone 0: II G Ex ia IIC T4 Ga zone 0: II D Ex ta IIIC T 85 C, IP6x in preparation Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 μh Permissible temperatures for in zone 0: C with p atm 0.8 bar up to. bar environment in zone or higher: C Connecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 60 pf/m cable inductance: signal line/shield also signal line/signal line: μh/m TRI-MATIC AG, CH - 6 Hünenberg Tel Fax TRI-MATIC SA, CH Yverdon-les-Bains Tél Fax TM_D_0engl.doc / 0 All information in this document can be changed without notice Seite / Page
3 DMP Miscellaneous Option SIL according to IEC 6508 / IEC 65 Current consumption signal output current: max. 5 ma signal output voltage: max. 5 ma Weight approx. 40 g Installation position any Operational life > 00 x 0 6 pressure cycles CE-conformity EMC Directive: 004/08/EC Pressure transmitters are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight deviations in the zero point for pressure ranges P N bar. Wiring diagrams -wire-system (current) p supply + -wire-system (current / voltage) supply + p V S V S supply I supply I/U signal + A/V Pin configuration Electrical connection ISO 4400 Supply + Supply Signal + (for -wire) Electrical connections (dimensions in mm) Binder 7 (5-pin) 4 Mx / metal (4-pin) Shield ground pin 5 4 field housing IN + IN - OUT+ cable colours (DIN 4700) wh (white) bn (brown) gn (green) gn/ye (green / yellow) standard option ISO 4400 Binder Series 7 5-pin Mx 4-pin cable outlet with PVC cable (IP 65) (IP 67) (IP 67) (IP 67) 4 compact field housing cable outlet, cable with ventilation tube (IP 67) (IP 68) 5 universal field housing stainless steel.4404 (6 L) with cable gland M0x.5 (ordering code 880) and other versions on request 4 standard: m PVC cable without ventilation tube (permissible temperature: C) 5 different cable types and lengths available, permissible temperature depends on kind of cable TRI-MATIC AG, CH - 6 Hünenberg Tel Fax TRI-MATIC SA, CH Yverdon-les-Bains Tél Fax TM_D_0engl.doc / 0 All information in this document can be changed without notice Seite / Page
4 DMP Mechanical connections (dimensions in mm) standard for accuracy 0.5 / 0.5 % standard for accuracy 0. %; SIL- and SIL-IS-version option G/" DIN 85 G/" DIN 85 with ISO 4400 with ISO 4400 G/" EN 87 G/" open port G/" DIN 85 with flush sensor G/4" DIN 85 G/4" EN 87 /" NPT /4" NPT metric threads and other versions on request TRI-MATIC AG, CH - 6 Hünenberg Tel Fax TRI-MATIC SA, CH Yverdon-les-Bains Tél Fax TM_D_0engl.doc / 0 All information in this document can be changed without notice Seite / Page 4
5 Code DMP DMP Pressure Input Output 4 0 ma / -wire 0 0 ma / -wire 0 0 V / -wire Intrinsic safety 4 0 ma / -wire SIL 4 0 ma / -wire SIL with intrinsic safety 4 0 ma / -wire Accuracy standard for P N 0.4 bar standard for P N < 0.4 bar option for P N 0.4 bar option Electrical connection Male and female plug ISO 4400 Male plug Binder series 7 (5-pin) Cable outlet with PVC cable Cable outlet Male plug Mx (4-pin) / metal Compact field housing stainless steel.405 Mechanical connection G/" DIN 85 G/" EN 87 G/4" DIN 85 G/4" EN 87 G/" DIN 85 with flush sensor G/" DIN 85 open pressure port /" NPT /4" NPT Seals FKM EPDM NBR without (welded version) Special version standard gauge absolute 0 [bar] X E S ES 0.5 % 0.5 % % 0. % T A 0 T R 0 M F 0 0 H 0 0 N 0 0 N standard: m PVC cable without ventilation tube (permissible temperature: C), others on request cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, price without cable welded version only with pressure ports according to EN 87 TRI-MATIC AG, CH - 6 Hünenberg Tel Fax TRI-MATIC SA, CH Yverdon-les-Bains Tél Fax TM_D_0engl.doc / 0 All information in this document can be changed without notice Seite / Page 5
DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationDMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output
More informationDMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.
DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output
More informationDMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:
More information- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request
DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0.
More informationDMP 331i / DMP 333i LMP 331 i
DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma
More informationDMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO
DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request
More informationLMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor
LMP Screw-In Transmitter with piezoresistive Stainless Steel Sensor flush diaphragm hydrostatic level measurement of clean, thin fluid media nominal pressure ranges from 0... 40 mbar up to 0... 40 bar
More informationDMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.
Precision Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Version with cooling element accuracy according to IEC 0770: 0. % FSO Precision Pressure
More informationDCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor
Industrial Pressure Transmitter with i²c interface Stainless Steel Sensor Accuracy according to IEC 60770: standard: ± 0. % FSO option: ± 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Digital
More informationDS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0
More informationDS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections
Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded
More informationDMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore
GmbH Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 26 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de Data Sheet Page /5
More informationDMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore
Pressure Transmitter for Shipbuilding and Offshore ceramic sensor accuracy: 0.25 % FSO BFSL (0.50 % FSO IEC 60770) nominal pressure ranges from 0... 0.6 bar up to 0... 600 bar The pressure transmitter
More informationDS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO
Ceramic Sensor accuracy according to IEC 600: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Contacts, or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire:
More informationDS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection
with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges
More informationLMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.
Slimline Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire: 4... 20 ma
More informationPressure transmitter For applications in hazardous areas Model IS-3
Pressure Pressure transmitter For applications in hazardous areas Model IS-3 WIKA data sheet PE 81.58 for further approvals see page 10 Applications Chemical, petrochemical industry Oil, natural gas Machine
More informationTPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN
TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN Main features Ranges: from: 0...1000 to 0...5000 bar Output signal 4...20mA 2 wires / 0,1...5,1Vdc / 0.1...10.1Vdc / 0...5Vdc / 0...10Vdc
More informationInductive sensor. 2-wire, analog output BI8-M18-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationInductive sensor BI1.5-EG08K-Y1
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationInductive sensor With analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full
More informationPROPORTIONAL VALVES Sentronic plus
04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART, PA Built in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and
More informationUltrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD
ATEX II 3 G approval Gases and vapors IIC group, zone 2 Dusts IIIC group, zone 22 When used in Ex areas, the special conditions of the approval must be observed Safety clips to prevent inadvertent detachment
More informationMetric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar
Micro-Machined Silicon Transducers wet/dry differential mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar PXM409 Differential Series U 5-Point NIST Traceable
More informationGuide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area
Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1
More informationPMG. Vibration Energy Harvesters
FEATURES Designed to power high performance Wireless Sensor Nodes. High power output up to 27.5mW High reliability design, including hermetically-sealed stainless steel case. Intrinsically Safe for use
More information45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5
SPACEGUARD SERIES Description 1-12 metre sensing range 16 to 56 parallel scanning beams Active height of 0 mm to 2520 mm Detector length of 1928 mm to 2648 mm 3 different channel placement models Cable
More informationJUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22
Data Sheet 605055 Page 1/10 Type 605055, Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat and double thermostat with capillary or rigid thermowell
More informationMicro-Machined Silicon Transducers
Micro-Machined Silicon Transducers wet/wet differential Pressure Models mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar PXM409 Differential Series Standard
More informationMagnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationPhotoelectrics Through-beam Type PA18C.T..., DC
Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationMechanical flow switch for On/Off control
Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...
More informationUltrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151
Smooth sonic transducer face Cylindrical housing M18, potted Connection via M12 x 1 male Teach range adjustable via pushbutton or adapter Temperature compensation Blind zone: 2.5 cm Range: 40 cm Resolution:
More informationSentronic PLUS Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications
More informationMagnetic field sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationRSCC. Load cells. Special features. Data sheet
RSCC Load cells Special features - Load cell with SG measurement system - aximum capacities: 50 kg to 5 t - Hermetically sealed (IP68) - Rust resistant materials - Legal for trade to 3000 divisions, test
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationRK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics
RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output
More informationLevel Measurement silometer FMC 420, FMC 423
Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level
More informationTFRH Hygienic RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy
More informationSelection matrix for electronic pressure switches
Selection matrix for electronic pressure switches Type / series 0500 050 050 05 050 0570 050 05 05 05 050 05 05 05 055 056 Page 09 09 7 0 5 5 5 5 9 9 9 9 9 9 Technology Measuring cell ceramic / thick-film
More informationGuide for installers. METTLER TOLEDO MultiRange System solution Point Ex.
Guide for installers METTLER TOLEDO MultiRange System solution Point Ex www.mt.com/support System solution Point Ex Contents Contents Page 1 Safety precautions... 4 2 System overview... 5 2.1 Using the
More informationSingle Point Flow Monitor SW118 SW119
SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either
More informationMID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J
MID-EX-E Figure: MID-EX-E*010* J2013333 Robust and safe magnetic flow meter for general mining applications, optional with additional measuring Corresponds to the European standards EN 13849-1 (Performance
More informationSITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43
Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.
More informationJUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22
Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat
More informationLinear encoders without bearings incremental System for linear motion feedback
Features Robust magnetic sensing method Output signals A 90 B with index signal Output circuits: HTL/push-pull and TTL/RS422 Resolution up to 5 µm (4-times evaluation) Non-contact, wear-free sensing system
More informationPendant Light Fitting IEC Series 6470/2
> Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E
More informationSentronic PLUS. Electronic Pressure Regulator. Installation Manual
Sentronic PLUS Electronic Pressure Regulator Electronic Pressure Regulator Sentronic PLUS Sentronic PLUS Electronic Pressure Regulator General Electrical Characteristics Nominal Diameter DN (mm) Voltage
More informationPressure transmitter COMPACT IO-Link,
Pressure transmitter COMPACT IO-Link, for diaphragm seal operation, Type series CA1510 Features Digital pressure transmitter with IO-Link V1.1 output signal Data transmission rate COM 3 (230.4 kbaud) Hygienic
More informationCapacitance Level Measurement Electronic insert FEC 12
Technical Information TI 50F/00/en Capacitance Level Measurement Electronic insert FEC Smart electronic inserts for Multicap probes DC..TE/TA and DC..E/A with HART protocol and integrated linearisation
More informationProcess transmitter RMA422
Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set
More informationSignet 2250 Hydrostatic Level Sensor
Signet 2250 Hydrostatic Sensor *32250.090* 32250.090 Rev. A 10/06 English English Safety Instructions 1. Prior to installation or removal: Depressurize and vent system Drain below sensor level 2. Confi
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationLinear flow control with actuator IFC
Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20
More informationMB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN
Multi-Barrier for PROFIBUS PA and FOUNDAION Fieldbus 10/63-6.11 EN P R O F I PROCESS FIELD BUS B U S Intrinsically safe power supply of up to 31 stations on the bus, cascadable multi-barrier Intrinsically
More informationProcess Transmitter RMA 422
Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog
More information3 Cleaning. 4 Technical data
EXC+ EXC- Sig- SIG+ SEN- SEN+ 2.4 Attaching cable to the analog board Attaching cable of the weighing cell to the system solution Connect the cable to the appropriate terminal strip of the Ex1 system solution
More informationEddy Current Probe System
CMSS 785 Eddy Current Probe System API-670 Proximity transducer system, 5 mm and 8 mm Eddy Current Probe System The CMSS 785 system is an eddy current type non-contact displacement/ vibration system, used
More informationContactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationMG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV
MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper
More informationPhotoelectric Sensors E3F2
Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel
More informationMaterial: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry Type 2REX-H-SR EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc
More informationElectronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de
More informationPanel-mounting Thermostats EM Series
Postal address: 3603 Fulda, Germany Phone: +44 279 6333 Fax: +44 279 63262 Phone: 3-697-JUMO -800-4-JUMO Fax: 3-697-867 Page /2 Panel-mounting Thermostats EM Series with, 2, 3 or 4 single-pole snap-action
More informationIndustriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500
Industriefunkuhren Technical Manual IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C37.118 / AFNOR NF S87-500 Module 7628 ENGLISH Version: 02.01-06.03.2013 2 / 20 7628 IRIG-B
More informationFTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process
FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]
More informationTECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT
RDP Customer Document TECHNICAL MANUAL DRAW-WIRE DISPLACEMENT TRANSDUCER TYPE DWT Doc. Ref CD1004L BS EN ISO 9001 Certificate No. FM13141 Affirmed by Declaration of Conformity USA & Canada RDP Electrosense
More informationQuality products from a single source
Velocity sensors Quality products from a single source For more than 50 years Brüel & Kjær Vibro has been a leading manufacturer of vibration measuring instruments and machine condition monitoring systems.
More informationMK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)
MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT) TECHNICAL DATA Measurement taken Position read sampling time (typical) Shock test DIN IEC68T2-27 Vibrations DIN
More informationTFR5 Room or outdoor temperature sensor. CombiTemp TM
Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical
More informationContactless encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED LED indicates measuring range Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024,
More informationOnline data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS
Online data sheet SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS A B C D E F H I J K L N O P R S T Detailed technical data Features Technology Ordering information
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M8 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationCapacitance Limit Detection nivotester FTC 420/421/422
Technical Information TI 127F/00/en Capacitance Limit Detection nivotester FTC 420/421/422 Limit switches in Minipac design for liquids and bulk solids Application Nivotester FTC 420...422 capacitive limit
More informationAbsolute Encoders Multiturn
The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft
More informationContactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151
Compact, rugged housing Many mounting possibilities Status displayed via LED Measuring range indicated via LED Immune to electromagnetic interference Measuring range programmable via Easy Teach Output
More informationConnecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath
Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.6 N LE 3 Function NEBV Connecting cables for valves Connection technology on left, field device side A1 Plug socket type A, EN 175301-803
More information-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.
Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.6 N LE 3 NEBV Connecting cables for valves Connection technology on left, field device side B2 Socket type B to industry standard,
More informationATEX. 50D (Pneumatic) Electronic pressure switch bar, bar, bar, bar, bar
0D (Pneumatic) Electronic pressure switch -... 0 bar, -... bar, 0... 6 bar, 0... 0 bar, 0... bar Fast error detection viamulti-colour display Easy to use pressure switch with clear display and intuitive
More informationConnecting cables for valves, round plug connectors Product range overview
Connecting cables for valves, round plug connectors Product range overview Version Type code Connection technology (Electrical connection 2) Electrical connection 1: socket M8x1 4-pin NEBV-M8W4L Plug M8x1,
More informationIONIVAC Transmitter ITR 90
IONIVAC Transmitter ITR 90 The ITR 90 is a optimized combination transmitter The combination of a hot cathode ionisation sensor according to Bayard-Alpert and a Pirani sensor permits vacuum pressure measurements
More information1 Inductive proximity switches. 5 Connecting cables. Highlights: New:
Highlights: - All-metal housings - Miniature sizes - Long operating distances - Extreme environmental conditions - Analog outputs New: - All-metal devices for food industry and sea-water applications -
More informationITER Product Catalogue. Total Pressure Measurement V Page 1 / 15
ITER Product Catalogue V20170405 Page 1 / 15 Content TPG 300 Passive Gauge Controller... 3 Pirani/Cold Cathode Measurement Board... 5 Interface and Relay Boards... 6 Pirani Gauge TPR 018... 7 Cold Cathode
More informationSpeed sensor MiniCoder GEL 2471
Speed sensor MiniCoder GEL 2471 for electrically conducting toothed-wheels Technical information version 10.02 The MiniCoder family from Lenord + Bauer offers spacesaving solutions for the contactless
More informationLevel Measurement Point level measurement - RF Capacitance switches
Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces,
More informationCombiSeries. Making temperature, pressure and conductivity measurement safe and convenient.
CombiSeries Making temperature, pressure and conductivity measurement safe and convenient. Another innovation from Baumer: The CombiSeries instruments facilitate safe and convenient process control Today
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications
ABB MEASUREMENT & ANALYTICS DATA SHEET AZ00 series Zirconia oxygen analyzer for small boiler applications AZ 00 SE RIE S Z I RCON I A OX YG EN ANALY ZE R FOR SMALL BOILE R APPLIC ATIONS DS/AZ00-E N RE
More informationPSI-MOS-RS232/FO 850 E Serial to Fiber Converter
PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to
More informationConnecting cables NEBS, for sensors
Connecting cables NEBS, for sensors Connecting cables NEBS, for sensors Product range overview Function Version Type code Connection technology (Electrical connection 2) Connecting cable Cable characteristic
More informationRosemount 1151 Smart Pressure Transmitter
Rosemount 1151 Smart Pressure Transmitter Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Connect the Wiring and Power Up Step 4: Set Switches Step 5: Configuration Step 6:
More informationBimetal Temperature Switch
Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,
More informationPhotoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8
Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 25 300 mm Laser class 1, red, 655 nm, acc.
More informationPhotoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8
Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 25 100 mm Laser class 1, red, 655 nm, acc.
More information