24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual
|
|
- Everett Golden
- 5 years ago
- Views:
Transcription
1 24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual
2 24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual, Part Number Copyright 2011, Telect, Inc., All Rights Reserved Telect and Connecting the Future are registered trademarks of Telect, Inc N Madson St., Liberty Lake, Washington Telect assumes no liability from the application or use of these products. Neither does Telect convey any license under its patent rights nor the patent rights of others. This document and the products described herein are subject to change without notice. About Telect Telect offers complete solutions for physical layer connectivity, power, equipment housing and other network infrastructure equipment. From outside plant and central office to inside the home, Telect draws on more than 25 years of experience to deliver leading edge product and service solutions. Telect is committed to providing superior customer service and is capable of meeting the dynamic demands of customer and industry requirements. This commitment to customer and industry excellence has positioned Telect as a leading connectivity and power solution provider for the global communications industry. Technical Support getinfo@telect.com Phone: or Telect, Inc. USA Mexico Telect, Inc., All Rights Reserved, A0 Page ii
3 24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual Table of Contents Chapter 1: Introduction Tools Required Additional Parts Assemblies... 2 Chapter 2: Installation Installing Cable Clips Installing the Optional Cable Clamp Kit Installing Patch Plates Preparing the Grommet Mounting the LANLINXS Enclosure Installing the Incoming Cable Securing Cable to the Enclosure Using LANLINXS to Patch Only Splice and Patch: Installing Pigtails Splicing and Patching: Splice Pigtails to Incoming Cables Attach Incoming Cable to Splice Cassette Tray Attach Pigtails to Splice Cassette Tray Splice Incoming Cable to Pigtail Splicing and Patching: Route and Secure the Cable Route Pigtails Mounting the Splice Cassette Routing the Incoming Cable Repeat the Cabling Finish Chapter 3: Accessories and Ordering Information Page 2-iii
4 List of Figures Figure 1-24-Fiber LANLINXS Enclosure... 1 Figure 2 - Cable Clip... 3 Figure 3 - Cable Clamp Kit... 4 Figure 4 - Cable Bracket on Enclosure... 4 Figure 5 - Patch Plate Installation... 5 Figure 6 - Rubber Grommet... 6 Figure 7 - Rubber Grommet at Cable Entry Location... 6 Figure 8 - Example of Installed Panel...8 Figure 9 - Securing the Cable... 9 Figure 10 - Patch-Only Fiber Routing Figure 11 - Splice Cassette (Part 055-SPLICE-5000) Figure 12 - Cable Clip Figure 13 - Cable Routing for Splice and Patch Figure 14 - Splice Cassette Installation Figure 15 - Splice and Patch Installation Page 2-iv
5 Chapter 1: Introduction This guide explains how to wall-mount the 24-fiber LANLINXS ( ) and the 48-fiber LANLINXS ( ) enclosures and how to route and secure the fiber-optic cable within the enclosures. Figure 1-24-Fiber LANLINXS Enclosure 1.1 Tools Required You need the following tools: Marking pen Phillips screwdrivers Utility knife Heat gun (optional) Page 1
6 1.2 Additional Parts LANLINXS Panels require the following additional parts that must be ordered separately: Patch plates with adapters Fiber pigtails Labels to identify pigtails (masking tape or pre-numbered cable labels) When patching only (no splice), you do not need splice cassettes or pigtails. However, you do need adapter plates to terminate the incoming cable. Refer to Accessories and Ordering Information on page 15 to order additional parts. 1.3 Assemblies Each enclosure consists of a metal chassis with a locking door, cable entry slots, cable-tie brackets, splice cassettes, entry port grommets, and spools for fiber routing. Each enclosure also comes with an installation kit: Cable ties, 3 inches (33) Cable ties, 4.75 inches (5) Cable clips (22) Designation label (1) Installation instructions (1) Table clamp (1) #9-18 x 1/4 screws (4) Splice sleeves (25) Page 2
7 Chapter 2: Installation Please read these instructions carefully before beginning installation. If you need assistance, call Technical Support at (domestic calls), or (Option 2), or us at Inspect equipment after unpacking and compare it to the packing list. Immediately report any shipping damage, defects, or missing parts to Telect at Keep all documentation that comes with your shipment. Telect is not liable for shipping damage. If the product is damaged, notify the carrier and call Telect s Customer Service Department at (domestic only) or for further recourse. NOTE: For service or warranty information, please visit telect.com website, or inquiries to getinfo@telect.com and click on the Support tab, or phone us at (domestic only) or This section covers how to prepare and mount the LANLINXS enclosure. 2.1 Installing Cable Clips Stick-on cable clips mount onto the inside back of the enclosure. Procedure steps: 1. Remove the paper from the back of the cable clips. 2. Install the cable clips at desired locations. Press firmly. This procedure is complete. Figure 2 - Cable Clip Page 3
8 2.2 Installing the Optional Cable Clamp Kit Attach the clamp bracket to the top or bottom of the enclosure, next to the cable entry slot. Figure 3 - Cable Clamp Kit Figure 4 - Cable Bracket on Enclosure Page 4
9 2.3 Installing Patch Plates Procedure steps: 1. Make sure the latches on the patch plates are pulled out. 2. Insert the patch plate (adapter key way facing up) latches into their mounting holes on the LANLINXS enclosure bulkhead. 3. Push the patch plates until they are flush with the bulkhead. 4. Push in the latches to secure each plate. Adapter plate Latch Adapter key ways Bulkhead Figure 5 - Patch Plate Installation This procedure is complete. Page 5
10 2.4 Mounting the LANLINXS Enclosure Procedure steps: 1. Place the mounting-hole template against the wall where you want to mount the enclosure. 2. Mark the location of the appropriate template holes onto the wall. 3. Install suitable wall anchors (not included). 4. Secure the enclosure to the wall. This procedure is complete. 2.5 Securing the Cable to the Enclosure Procedure steps: 1. Score the grommet with a utility knife at the desired cable entry location. Refer to Figures 6 and 7 2. Using a Phillips screwdriver, remove two screws from the cable bracket at the top or bottom of the panel. Figure 6 - Rubber Grommet 3. Place the bracket around the cable in the desired location. Figure 7 - Rubber Grommet at Cable Entry Location Page 6
11 4. Reinstall the two screws to hold the cable bracket firmly in place. This procedure is complete. 2.6 Installing the Incoming Cable 1. Push the cable through the hole that you cut in the grommet. 2. Mark the cable according to the number of wraps you wish to store in the LANLINXS enclosure. Use the tables below to determine where to make the mark. The tables provide the lengths needed for an incoming cable to complete one, two, or three wraps. Table 1 - Splice & Patch Storage Wraps (Enclosure & Cassette) Marking Location: Inches Cm Table 2 - Patch Only ± ±2 Storage Wraps Marking Location: Inches Cm ± ± ±2 The number of wraps the cables make within the LANLINXS enclosure is left up to installer preference. For other lengths or paths, use the spools and cable clips, and maintain proper bend radius. Page 7
12 Procedure steps: 1. Slide the grommet up the cable past the mark on the cable jacket. 2. (Optional) Apply heat-shrink tubing around the jacket cut point. Keep half of the heat-shrink tube length over the cable jacket, and the other half over the exposed buffer tubes or fiber strands. See Figure 8 for an example of the installed cable and panel. This procedure is complete. Figure 8 - Example of Installed Panel Page 8
13 2.7 Using LANLINXS to Patch Only Use the instructions in this section if you are using the LANLINXS enclosure to patch only. Procedure steps: 1. From the cable entry end, wrap the fiber strands counter-clockwise around the spools and through the cable clips. For bottom cable entry, route the strands clockwise. 2. Attach the connectors to the column of patch plate adapters closest to the back wall of the enclosure. Attach the connectors in order, from top-to-bottom, using Table 3, Fiber Connection Color Codes, on page 10. Figure 9 - Patch-Only Fiber Routing 3. Repeat Steps 1 & 2 for the next group of 12 fiber strands, and attach the connectors to the next column of adapters (1-12, top to bottom). NOTE: Always load the patch plates from top to bottom and from the rear of the LANLINXS enclosure to the front of the enclosure. 4. Close the cable clips to secure the positions of the fiber strands. Do not pull the cable taut. Page 9
14 Refer to the following table for fiber connection color codes. Table 3 - Fiber Connection Color Codes For this connection: Use this color: 1 Blue 2 Orange 3 Green 4 Brown 5 Gray 6 White 7 Red 8 Black 9 Yellow 10 Purple 11 Pink 12 Aqua This procedure is complete. 2.8 Splice and Patch: Installing Pigtails Use the instructions in this section if you are using the LANLINXS enclosure to splice and patch. Procedure steps: 1. Attach the pigtail connectors to the column of patch plate adapters closest to the back wall of the enclosure. Always attach pigtails from top to bottom and from the back wall of the enclosure to the front. Label the pigtails accordingly. 2. Route the pigtails around the spools to take up the amount of desired slack. 3. Repeat Steps 1 & 2 for each group of 12 pigtails, then go to the next section. NOTE: The number of wraps that pigtails and incoming cable fibers make within the LANLINXS enclosure and the splice tray is left up to installer preference. This procedure is complete. Page 10
15 2.8.1 Splicing and Patching: Splice Pigtails to Incoming Cables Skip this section if you are patching only. Procedure steps: 1. Unsheath the fiber-optic cable by cutting the outside jacket to an approximate length of inches (600 mm). 2. Secure the cable using the cable clip (provided). (See Figure 2 on page 3.) 3. Determine and prepare the appropriate length of each fiber to be spliced according to splicing machine recommendations. 4. Remove the desired splice tray. 5. Splice the bare fibers from the pigtails to the outside plant cable in equal length. Use the provided heat-shrink protective sleeves. 6. Once the splicing is complete, carefully route the pigtails around the provided storage spools. This procedure is complete Splice Incoming Cable to Pigtail Figure 10 - Splicing Pigtails Procedure steps: 1. Wrap the fiber strands of the incoming cable around the inside of the splice cassette once or twice counter-clockwise. For bottom cable entry, wrap the fiber strands clockwise. 2. From the first pigtail bundle (1-6), wrap the fiber strand from pigtail 1 twice clockwise around the inside of the splice cassette. For bottom cable entry, wrap the fiber strand counter-clockwise. 3. Trim away the excess fiber length, but leave enough fiber for splice preparation. Remove the fiber from the splice cassette to the splice station. NOTE: Use this trimmed fiber to measure and trim the length of the bundle s remaining five fibers. 4. Splice the pigtail fiber strand to the appropriate 900-μm colored fiber strand from the incoming cable. Page 11
16 5. Place the completed splice into the splice holder. 6. Repeat Step 2 through Step 5 to splice the remaining pigtail fibers to the incoming cable s color-coded fiber strands. Splice the pigtails in order. Refer to Table 3, Fiber Connection Color Codes, on page 10 to follow the color-codes. 7. Carefully tuck in any stray fiber strands so that they will not be pinched. Replace the cover plate on the splice cassette. This procedure is complete. Figure 11 - Splice Cassette (Part 055-SPLICE-5000) Page 12
17 2.9 Mounting the Splice Cassette 1. Slide the splice cassette onto the threaded post. 2. Secure the cassette with the wing nuts Finish 1. Use the adhesive designation label to identify each connection. 2. Apply the designation label to the inside of the enclosure door. 3. Close and lock the enclosure. Figure 12 - Splice Cassette Installation Page 13
18 This page intentionally left blank. Page 14
19 Chapter 3: Accessories and Ordering Information Contact your Telect Customer Service Representative at to order connectorized cables or any of the parts listed below. Table 4-6-Port Patch Plates Adapter Part Number SC/UPC SC/APC FC/UPC FC/APC ST/UPC Table 5-8-Port Patch Plates Adapter Part Number SC/UPC SC/APC FC/UPC FC/APC ST/UPC Table 6 - Accessories Description Splice Cassette Cable Clamp Bonding/Grounding Kit Terminated Pigtails Part Number 055-SPLICE CLMP-5000 KIT-BOND Contact Telect Customer Service. Page 15
20 This page intentionally left blank. Page 16
IP-LINX. Installation Guide
Installation Guide Installation Guide, 146653-4 Copyright 2017, Telect, Inc. All Rights Reserved Telect and Connecting the Future are registered trademarks of Telect, Inc. 22425 East Appleway Ave. # 11
More informationIP-LINX Fiber :: X-XXXX
Fiber :: 055-797X-XXXX User Manual Telect, Inc. All rights reserved. 146653-A0 Table of Contents Chapter 1: Introduction...3 1.1 Tools Required...3 1.2 Additional Parts...3 1.3 Assemblies...3 Chapter 2:
More informationCONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL
CONNECTING THE FUTURE 19" LINXS LIGHTWVE INTEGRTED CROSS-CONNECT SYSTEM USER MNUL 109003 Issue Rev 2 19" Lightwave Integrated Cross-Connect System (LINXS) User Manual Document Number 109003 Issue Rev 2
More informationADF Module. Installation Guide. 1.1 Overview
ADF Module Installation Guide 1.1 Overview The installation sheet is divided into three sections. Section 1.2 Description on page 2 describes the areas on the frame and modules dedicated to the mounting
More information3M Distribution Box (DDB)
3M Distribution Box (DDB) Merged Copper and Fiber Pole/Post Mount Enclosure Installation Instructions November 2015 78-0015-2736-1-A 2 November 2015 78-0015-2736-1-A Contents 1.0 General 2.0 Enclosure
More informationOptical Distribution Box 300 Installation Guide. Version : R0.0
Optical Distribution Box 300 Installation Guide Document No. : OD16-546-L-01 Version : R0.0 Date: 21-Mar-2018 IMPORTANT INSTRUCTIONS When using fiber optic equipment, basic precautions should always be
More informationHCS - HES Cabling Systems
HCS - HES Cabling Systems Installation Manual for HCS High-Capacity Fiber-Optic Rack-Mount Cabinets Be sure to read and completely understand this procedure before applying product. Be sure to select the
More informationFOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N
FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N In-line and butt version Cold applied re-usable fiber optic closure Contents 1 Introduction 1.1 Product description 1.2 Capacity 2 General
More informationNext Generation Frame (NGF) Fiber Combination Block (FCB) User Manual)
Next Generation Frame (NGF) Fiber Combination Block (FCB) User Manual) Fiber Combination Block Content Page INTRODUCTION............................................................................. 2 Revision
More information3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket
3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket For use with 3M SLiC Free-Breathing Fiber Optic Closures and Terminals Instructions November
More informationClearview. Classic Cassettes. Installation Manual. Clearview Classic (HD) High Density. Part #: Rev: A Updated:
Clearview Classic Cassettes Installation Manual Clearview Classic (HD) High Density Part #: 016781 Rev: A Updated: 11.2014 7050 Winnetka Ave N Minneapolis, MN 55428 Direct: 763.476.6866 National: 800.422.2537
More information3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR
3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR Instructions July 2010 78-8135-0094-5-K 3 1.0 General 1.1 3M Fiber Optic Splice Closure 2178-XSB The
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS BEFORE INSTALLING OR ADJUSTING THIS PRODUCT, PLEASE READ THESE INSTRUCTIONS CAREFULLY. PLEASE KEEP THIS GUIDE FOR FUTURE REFERENCE FIBER OPTIC SWING-OUT PATCH PANEL INSTRUCTION
More informationPanduit Recommended Best Case Practice Split Fibre
Panduit Recommended Best Case Practice Split Fibre Panduit Corp. 2009 BEST PRACTICES PN526 Table of Contents 1.0 Enclosure Prep... 2 2.0 Fibre Cable Prep and Installation... 2 3.0 Pigtail Installation...
More informationFIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays
FIST-MB2-S I N S T A L L A T I O N I N S T R U C T I O N FIST Medium Box for Cable Splicing Only Contents 1 Introduction 1.1 Product description 2 General 2.1 Tools 2.2 Kit contents 3 Installation and
More information2179-CD Series Fiber Optic Splice Closure. Installation Instructions
2179-CD Series Fiber Optic Splice Closure Installation Instructions 1.0 Product Introduction The new 3M TM 2179-CD Series Fiber Optic Splice Closure can be used in buried, underground, aerial, and pedestal
More informationSLiC Fiber Aerial Closure System
3 SLiC Fiber Aerial Closure System SLFC 533-SP SLFC 533-TS SLFC 733-SP Instructions May 2005 78-8135-4502-3-B N C H E S R A N G E M IL L IM E T E R S.4 10.6.8 A B C 15 20 I 1.0 Kit Contents Note: Examine
More informationNC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM
NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM Content 1. General 5 2. The products of NC-1000 system 6 3. Mounting of the frame 8 4. Earthing of the frame 8 NC-1000 FIBRE OPTIC
More information3M Fiber Optic Wall Mount Enclosure 8430 Series
3M Fiber Optic Wall Mount Enclosure 8430 Series Installation Instructions January 2014 3 78-0013-9429-1-A Table of Contents 1.0 Description...3 2.0 Parts...4 3.0 Assembly...4 4.0 Mounting the Enclosure...6
More informationFOSC 450 C6 and D6 Closures
FOSC 450 C6 and D6 Closures I N S T A L L A T I O N I N S T R U C T I O N Fiber Optic Splice Closure 1. General Product Information The FOSC 450 C6 and D6 fiber optic splice closures use compressed gel
More informationMedium Box for Cable Termination
FIST-MB2-T I N S T A L L A T I O N I N S T R U C T I O N Medium Box for Cable Termination Contents 1 Introduction 1.1 Product description. 2 General 2.1 Tools 2.2 Kit contents 3 Installation and pre assembling
More informationGF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual
Instruction manual GF/KSW/48 Page Nr 1 GF-KSW-48 Series of Fiber Optic Distribution Box Instruction Manual 1. General Introduction GF-KSW-48 series of fiber optic distribution box is applicable to fiber
More informationGel-sealed in-line fiber optic closure
SCIL-C Gel donut INSTALLATION INSTRUCTION TC-1363-1-IP Rev A, Oct 2017 www.commscope.com Gel-sealed in-line fiber optic closure Contents 1 General 2 Sizing and product kit information 3 Installation conditions
More information3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR
3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR Instructions September 2017 78-8130-5055-2-M 2 September 2017 78-8130-5055-2-M 1.0 Kit Contents 2.0 General...
More information3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR
3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR Instructions July 2010 3 1.0 Contents 1.0 General...3 2.0 Kit Contents...3 3.0 Cable Preparation...4 4.0
More information18mm ECAM Cable Entry Port
18mm ECAM Cable Entry Port Instructions October 2006 1.0 Introduction The 3M 18mm ECAM (External Cable Assembly Module) Cable Entry Port Kit is designed to accept fiber optic cables with external diameters
More information3M Fiber Optic Splice Closure 2178-L/S Series with Gasket
3M Fiber Optic Splice Closure 2178-L/S Series with Gasket Instructions for: 3M Fiber Optic Splice Closures 2178-L/S Series 3M Flame Retardant Fiber Optic Splice Closures 2178-L/S/FR 3M Cable Addition Kit
More information27mm ECAM Double Cable Entry Port
27mm ECAM Double Cable Entry Port Instructions October 2006 1.0 Introduction The 3M 27mm ECAM Double Cable (External Cable Assembly Module) Entry Port is designed to accept fiber optic loose tube & central
More informationWCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12)
Corning Cable Systems SRP-003-448 Issue 3, October 2000 Page 1 of 6 WCH Slack Storage Housing (WCH-SSH-2 & WCH-SSH-4-12) Figure 1 Table of Contents 1. General... 1 2. Description... 1 3. Tools and Materials...
More informationLGX Compatible (LSX) Connector Module) User Manual)
LGX Compatible (LSX) Connector Module) User Manual) 15948-A LSX Connector Module (72-Position Module Shown) Content Page 1 DESCRIPTION... 3 2 DIMENSIONS AND SPECIFICATIONS... 5 3 INSTALLATION... 6 3.1
More information3M Coupling Tray FDTC-10S-COUPLINGTRAY
3M Coupling Tray FDTC-10S-COUPLINGTRAY for use with 3M Fiber Dome Closures FDC 10S Instructions July 2010 3 1.0 Introduction The 3M Coupling Tray FDTC-10S-COUPLINGTRAY can accommodate up to 10 loose tubes.
More information2178-L/S Series Fiber Optic Splice Case with Gasket
2178-L/S Series Fiber Optic Splice Case with Gasket Instructions for: 2178-S Splice Case 2178-LS Splice Case 2178-LL Splice Case 2181-LS Cable Addition Kit May 1997 34-7041-9949-5-A 1 Table of Contents
More informationINSTALLATION INSTRUCTIONS
LIGHTGUARD 350-20-WTC SEALED FIBER OPTIC CLOSURE VIEW ONLINE TABLE OF CONTENTS: GENERAL...2 SPECIFICATIONS...2 PACKAGE CONTENTS...3 PACKAGE CONTENTS: ACCESSORIES...3 RECOMMENDED TOOLS...3 ADD-ON COMPONENTS...4
More information2178 Fiber Optic Splice Case and 2181 Cable Addition Kit
2178 Fiber Optic Splice Case and 2181 Cable Addition Kit Instructions January 1994 Issue 1, 34-7029-6387-6 1 2 Contents: 1.0 General... 4 2.0 Specifications... 4 3.0 Kit Contents... 5 SECTION 1: 2178 Splice
More informationCOYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x cm cm x cm)
OCTOBER 2004 COYOTE CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (15.24 cm x 55.88 cm 21.59 cm x 55.88 cm) Be sure to read and completely understand this procedure before applying
More informationFOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15
FOSC 400 Ordering Guide For Closures and Accessories Section I 3 How to Order FOSC 400 Closures Section II 5 How to Order Accessories for FOSC 400 Closures Section III 9 Other FOSC Fiber Optic Splice Closures
More information6000 Series Patch Panel Terminating Instructions
6000 Series Patch Panel Terminating Instructions INTRODUCTION The 6000 Series patch panels include a unique feature not found on any other patch panel. This feature allows you to angle each of the four
More informationOFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation
OFDC-B8-72 I N S T A L L A T I O N I N S T R U C T I O N Outdoor fiber distribution closure Content 1 Introduction 2 Kit content 3 Closure preparation 4 Cable preparation 4.1 Feeder cable 4.2 Drop cable
More information3 SLiC Aerial Closure with Rubber End Seal
3 Aerial Closure with Rubber End Seal Instructions 1.0 General 1.1 This instruction bulletin describes the assembly of the 3M Aerial Closure with external bonding hanger brackets. These closures are suitable
More informationFOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block
FOSC-450D I N S T A L L A T I O N I N S T R U C T I O N Fiber Optic Splice Closure Content 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Accessories 2.4 Capacity 3 Preparation of the closure 4
More informationSection Communications Optical Fiber Backbone Cabling
Part 1 1.1 Related Documents 1.1.1 Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specifications Sections apply to this Section. 1.2 Related
More informationHD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity
HD Flex Patch Panel Part Numbers: FLEX1UPN**, FLEX2UPN**, FLEX4UPN** Panduit Corp. 2018 INSTALLATION INSTRUCTIONS Note: HD Flex Patch Panels are compatible with HD Flex Fiber System Components. HD Flex
More information2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table
FIST-GCO2-F INSTALLATION INSTRUCTION GCO2-FC GCO2-FD Content 1 Introduction 2 General 2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table 3 Installation
More information3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter
3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter Instructions January 2010 3 1.0 General 1.1 The 3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter(s) protects, organizes and stores
More informationLANmark-OF ENSPACE Patch Panel
LANmark-OF ENSPACE Patch Panel PRODUCT INSTALLATION GUIDE September 2016 v0.11 LANmark-OF ENSPACE Patch Panel PRODUCT INSTALLATION GUIDE Part Number Description Product References NSPACE.PP1U NSPACE.PP2U
More informationDS1 Cross-Aisle Panel
DS1 Cross-Aisle Panel Model 005-0005-0100 Installation Guide 1.1 Overview 1.1.1 Inspection Compare the contents of the DS1 Cross-Aisle Panel shipping container with the packing list. Call Telect if anything
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS MO036A N-HNS (Building Node Cabinet) N-HNS (BUILDING NODE CABINET) Contents Product description Technical data ODF Splice module Cabling organisation Cable/tube/fibre handling
More informationSJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1
Fiber Optic Splice Closure 1. Introduction 1.1 General SAMJIN s SJOF-BS604B protects fiber optic splicing point in various installation conditions such as aerial, manholes, ducts, wall and direct buried
More informationLTX Optical Distribution Panels. Ordering Guide
Contents LTX Optical Distribution Panels... 1... 1 Section One: LTX Overview... 3 1RU and 2RU Panels... 3 4RU Panels... 3 Patch Panels... 3 Combination Panels Patch and Splice... 4 Section Two: Unloaded
More informationSeal Kits for BUDI Enclosures
Description BUDI is a product range of compact, wall mountable fiber enclosures for indoor and outdoor use. They are specifically designed for fast deployment and easy customer connection. The FIST management
More informationCrimp & Cleave Termination Instructions for SEL ST Connectors
Your Optical Fiber Solutions Partner Crimp & Cleave Termination Instructions for SEL ST Connectors For Use With: ST Termination Kit (SEL, Part Number BT05402-01) 200 µm HCS Fiber-Optic Cable ST Crimp &
More information3M Better Buried Compound Compression Closure System
3M Better Buried Compound Compression Closure System Instructions March 2016 78-0015-2948-2-A Contents: 1.0 General...3 2.0 Kit Contents...3 3.0 Closure Selection Guide...4 4.0 LHS End Cap Installation...5
More informationFIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N
FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N 24 Address Point Fibre distribution point (FDP) Installation guide for fibre DP Contents 1 Kit Contents 2 Accessories 3 MOBRA installation
More informationOmniReach FTTX Solutions RealFlex DLX Universal Drop Cable Instruction Sheet
OmniReach FTTX Solutions RealFlex DLX Universal Drop Cable Instruction Sheet ADCP-90-457 Issue 1 9/2010 Content Page INTRODUCTION.............................................................................
More informationGENUINE PARTS CAUTION
GENUINE PARTS SATELLITE RADIO INSTALLATION INSTRUCTIONS 1. DESCRIPTION: SATELLITE RADIO SYSTEM 2. PART NUMBERS: XM tuner kit 999U9-NV003 XM antenna kit 999U9-VR000 Sirius tuner kit 999U9-NV004 Sirius antenna
More informationSLiC Fiber Aerial Closure 533 and 733
SLiC Fiber Aerial Closure 533 and 733 3M s SLiC fiber aerial closures are designed to enable service providers to costeffectively deploy aerial fiber networks in the access network (FTTN, HFC, and FTTP).
More information3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes
FIST-GCOG2-Dx24 I N S T A L L A T I O N I N S T R U C T I O N FTTH closure for micro-tubes and micro-cables Content 1 Introduction 2 Kit content 3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx24
More informationBulkhead Style Optical Panels. Telect LCX Series Installation Guide
Bulkhead Style Optical Panels Telect LCX Series Installation Guide Contents CHAPTER 1: LCX FIBER PANELS 5 1.1 General Information 5 1.1.1 LCX Fiber Splice Panels 5 1.1.1.1 LCX 1RU Fiber Splice Tray 24-Splice
More informationInstallation Instructions
TECP-30-260 Issue 2 July 2016 Installation Instructions OWB-S OWB-S Small Wall-mounted Box CONTENTS 1. Introduction 2. Kit content 3. Installation Instruction 3.1. Box installation 3.2. Conduit installation
More informationFiber Optic Splice Closure GPJ Instruction Manual. [Escribir texto]
Fiber Optic Splice Closure GPJ09-8205 Instruction Manual [Escribir texto] 0 Table of Contents 1. General Introduction 2 2. Specification 2 3. Structure 2 4. Installation instructions. 4 5. Operation procedure.
More informationWater blocking tape. Locator ridge HPA-0486
Table of Contents STANDARD RECOMMENDED PROCEDURE 004-138 ISSUE 1 MARCH 2012 PAGE 1 OF 12 Sheath Removal and Mid-Span Access of Dielectric ALTOS Cable with FastAccess Technology p/n 004-138, Issue 1 1.
More informationFIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.
FIST-GCOG2 I N S T A L L A T I O N I N S T R U C T I O N TC-986-IP Rev A, Mar 2017 www.commscope.com FIST-GCOG2-Dx6 Content 1 Introduction 2 General 2.1 Abbreviations 2.2 Kit contents 2.3 Tools 2.4 Accessories
More information3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series
3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series Instructions Voltage Rating: 1000 V, Temperature Rating: 90 C Kit Contents 78-R1 78-R2 78-R3 78-R4 78-R5 Sleeve Set 1 1 1 1
More information3. Electronics and MMU2 unit assembly
Written By: Jakub Dolezal 2018 manual.prusa3d.com/ Page 1 of 34 Step 1 Tools necessary for this chapter Please prepare tools for this chapter: 2.5mm Allen key for M3 screws 2mm Allen key for nut alignment
More informationFACT Cable Termination Unit
FACT Cable Termination Unit INSTALLATION INSTRUCTION FACT-GSS NOTE: - the FACT-GSS multi-purpose splice shelves features Single Circuit and Single Element fiber management system technology - these shelves
More informationThe FiberMark1 offers an ideal solution for
Large Capacity Fiber Optic Splice Enclosure The Ideal Solution For Large Capacity Voice, Data, and Video Splicing Requirements. The FiberMark1 offers an ideal solution for larger fiber capacity voice,
More informationOpterna. Sliding Fiber Optic Patch Panel. Sliding Fiber Optic Patch Panel. Visit: Opterna.com. Data Center Solutions. Introduction
Introduction The Fiber Optic 19 Sliding Patch Panel has been designed to facilitate internal fiber management and also to maximize fiber density in 1U, 2U heights. The sliding tray provides easy access
More informationFiber Cable Preparation, Splicing, and Termination Instructions (CFDP210-EL24 Charlesr Fiber CFDP2 Pedlockr OSP Pedestal)
Equipment Issue 1 First Printing, May 2011 Preparation, Splicing, and Termination Instructions (CFDP210-EL24 Charlesr CFDP2 Pedlockr OSP Pedestal) 1. GENERAL 1.1 Document Purpose. This document provides
More informationPublic Works Division Lighting District Fiber Optic Specifications April 2009
Public Works Division Lighting District Fiber Optic Specifications April 2009 7000 Florida Street Punta Gorda, Florida 33950 Tele: 941.575.3600 Fax : 941.637.9265 www.charlottecountyfl.com/publicworks
More informationLoose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA
Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA NOTE: These installation instructions have been written for
More information3M Better Buried Closures
3M Better Buried Closures Instructions March 2016 78-0015-2945-8-A Contents: 1.0 General... 3 2.0 Kit Contents... 3 3.0 Closure Selection Guide... 4 4.0 LHS End Cap Installation... 5 5.0 Cable Preparations...
More informationNGF optical distribution frame
NGF optical distribution frame Contents Introduction 3 Product overview 3 Things to consider when ordering 4 Frame capacity requirements (important facts on trough space) 4 Frame lineup capacity comparisons
More informationInstallation Manual for New or Retrofit Installations
Installation Manual for New or Retrofit Installations Release Date: 24-August-2015 c Able Applied Technologies LTD. READ THE ENTIRE MANUAL COMPLETELY AND CAREFULLY BEFORE STARTING BEFORE YOU BEGIN ASSEMBLY
More informationFollow The Leader In Shielded Technology
1970s Vampire Tap 1990s Shielded Modular Jack 190s 4 Position Data Connector Follow The Leader In Shielded Technology The new AMP-TWIST Jack is our latest shielded product evolution. It can be terminated
More information3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)
3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462FN and 3M High Gel Reenterable Encapsulant 8882) Instructions April 2016 78813509979C Contents: 1.0 General... 1 2.0 Kit Contents...
More informationCoyote popup display set up instructions
Coyote popup display set up instructions Frame 1 2 3 Prepare frame for assembly by locating the purple hooks on top of the frame. Stretch frame to size, snapping magnetic locking arms together. Attach
More informationFurcation of a Central Tube Ribbon, Gel-Free, Non-Armored, 96- to 192-Fiber Cable into an OSE-UD
Furcation of a Central Tube Ribbon, Gel-Free, Non-Armored, 96- to 192-Fiber Cable into an OSE-UD P/N 004-277-AEN Issue 1 related literature Search www.corning.com/opcomm. Click on Resources. 1. Initial
More informationVIP-35 Manual. Video Inspection Probe
VIP-35 Manual Video Inspection Probe Foreword Thank you for purchasing our products. Before assembly and use, make certain that all of the parts you have ordered are present. Check the packaging carefully
More informationFOSC 400 A4 Fiber Optic Splice Closure
FOSC 400 A4 Fiber Optic Splice Closure I N S T A L L A T I O N I N S T R U C T I O N 1. General Product Information This installation practice provides instructions for installing Tyco Electronics FOSC
More information4320 SS-25 Self-Strip Terminating Block
4320 SS-25 Self-Strip Terminating Block Instructions May 2002 78-8130-7677-1 1.0 General The 3M 4320 SS-25 Self-Strip Terminating Block is a factory stubbed, self-stripping connecting block designed for
More informationGigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT
COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted
More informationPreferred ordering guide for NETCONNECT
Preferred ordering guide for NETCONNECT MEA Region Contents Copper solutions Category 6A products 3 Category 6A and Category 7 shielded copper cables 3 Category 6A modular shielded panels 3 Category 6A
More informationMT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products
MT-RJ Product Expansion Now 0 Variants of the MT-RJ Products In response to several customers, the MT-RJ product line has been expanded with an additional six color/key versions. In addition to the original
More informationASSEMBLY INSTRUCTIONS
ASSEMBLY INSTRUCTIONS Multiplexer Enclosure and Cabling December 00 Figure - Trase Unit and Multiplexer Enclosure BNC Coaxial Cables From s (in order) MULTIPLEXER MODEL: 00B R / / / / / / / 9 0 9 0 Multiplexer
More informationInstructions. Cable with Armor F CAUTION. October Rev A
3M Single Conductor Accessory Breakout Kits (BOK's) for use with 3M Cable Accessories (Terminations, T-Bodies and Push-On Elbows) For Use With Single Conductor Accessories On Three-Core Conductor Cables
More informationHigh Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions
High Density Block BRCP HD BRCP- 128/192/256 pair Installation Instructions Product Introduction The BRCP block is the latest generation of MDF terminal blocks developed by 3M, specifically designed for
More informationINSTALLATION MANUAL FOR THE TIMING LIGHT
INSTALLATION MANUAL FOR THE TIMING LIGHT May 12 2014 SPORTS SPLIT STEP 12566 LAZY ACRES CRT NEVADA CITY, CA 95959 www.sports-split-step.com vicborg70@gmail.com 530-272-7345 1 1. The installation of the
More informationGENUINE PARTS SATELLITE RADIO INSTALLATION INSTRUCTIONS. 1. DESCRIPTION: Satellite Radio System 2. APPLICATION: Frontier (2006~)
GENUINE PARTS SATELLITE RADIO INSTALLATION INSTRUCTIONS 1. DESCRIPTION: Satellite Radio System 2. APPLICATION: Frontier (2006~) Xterra (2006~) 3. PART NUMBERS: XM Tuner Kit 999U9-AS003 SIRIUS Tuner Kit
More informationMiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions
MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures 004-273-AEN, Issue 2 Table of Contents 1. General.... 1 2. Precautions.... 1 2.1 Cable Handling Precautions...
More informationInstructions for Use of Overlap Seam Repair Kit:
Instructions for Use of Overlap Seam Repair Kit: 3M has assembled a field repair kit to adhesively re-attach delaminated overlap seams on trailers or truck body sidewalls. If the overlap seams were previously
More informationLCC (Little Coaxial Connector) Installation Instructions)
LCC (Little Coaxial Connector) Installation Instructions) Content Page INTRODUCTION...1 Revision History...1 Trademark Information...1 1 TOOLS...2 1.1 Connection Tool Kit...2 1.2 Tool Illustrations...2
More informationBCS 4R DSX-3 Connectivity System. Models , , and User Manual
BCS 4R DSX-3 Connectivity System Models 010-8332-0410, 010-8332-0401, 010-8324-0410 and 010-8324-0401 User Manual BCS 4R DSX-3 Connectivity System Models 010-8332-0410, 010-8332-0401, 010-8324-0410 and
More informationInstruction manual. Midi Fiber Dome. Instruction manual
Midi Fiber Dome Instruction manual Product contents: - 1x Midi Fiber Dome - 1x Window Cut port seal - 1x sealing rubber (long) - 4x sealing rubber (short) - 4x stainless steel screw 4 x 25 T20-6x dummies
More information3M Fiber Closures BPEO
3M Fiber Closures BPEO 2 3M Fiber Closures BPEO The 3M Fiber Closures BPEO are designed with flexibility in application in mind. With a range of sizes, they can be deployed above grade (pole, facade) or
More informationBionic Elephant Trunk. Assembly Instructions
Bionic Elephant Trunk Assembly Instructions Equipment and Supplies Required items from the Bionics Kit and/or Materials Pack: 1. Tail fin (small) assembled 2 see Start Here for tail fin assembly instructions
More informationRetractaNet XS. Extractable Solutions for OSP. October 2012
RetractaNet XS Extractable Solutions for OSP October 2012 OSP Solutions RetractaNet XS Solution Simple concept reduces the need for skilled labor for installation Easy direct buried deployment in soft
More informationFOSC 400 C5 & D5 Fiber Optic Splice Closures
FOSC 400 C5 & D5 Fiber Optic Splice Closures I N S T A L L A T I O N I N S T R U C T I O N 1. General Product Information The FOSC 400 C5 and D5 closures are combination cable closures and splice organizers,
More informationINSTALLATION INSTRUCTIONS MO023A
INSTALLATION INSTRUCTIONS MO023A Nexans N3S ODF system NEXANS N3S ODF SYSTEM Content Product description Patching frame Splice frame Doors Splice module Patch module Protective cover and label panel Guides
More informationGENUINE PARTS. SIRIUS Under Glass Antenna Kit
GENUINE PARTS SATELLITE RADIO INSTALLATION INSTRUCTIONS 1. DESCRIPTION: Satellite Radio System 2. APPLICATION: Pathfinder (2006-2007) 3. PART NUMBERS: XM Tuner Kit 999U9-AS005 SIRIUS Tuner Kit 999U9-AS006
More information3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT
3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT For Tape Over Wire (TOW) and Wire-Over-Tape (WOT) Shielded Cable For 250 2000 kcmil cable with 650-mil primary insulation thickness Instructions
More information