What s New in Raven May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven

Size: px
Start display at page:

Download "What s New in Raven May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven"

Transcription

1 What s New in Raven May 2006 This document briefly summarizes the new features that have been added to Raven since the release of Raven Extensible multi-channel audio input device support Raven 1.3 includes support for multi-channel recording using both NI-DAQ (National Instruments Data Acquisition hardware) and ASIO (Audio Stream In/Out) audio input devices. The NI-DAQ technology provides input capabilities of up to 32 channels with an adjustable voltage range. ASIO devices provide 24-bit audio sample size capabilities. Both of these are Windows platform devices; the Macintosh version of Raven supports Apple s Core Audio, which allows for multi-channel recording. Power Spectra Calculation Raven 1.3 introduces a slight change in the calculation of power spectra. The new method includes energy in the negative frequency bins of the Discrete Fourier Transform, as well as normalization of the power spectrum by the number of points in the DFT window. Power measurements made using this method will differ from the same measurements performed with previous versions of Raven by a multiplicative factor of 2/Nfft (1/Nfft for the zero frequency component). To use this updated power spectra calculation, check the box on the OPTION screen that appears when Raven 1.3 starts for the first time. The new power spectra calculation should be used in cases when measurements need to be consistent with those made in Canary. The power spectra calculation method that Raven 1.3 uses can be changed by editing Raven s preferences file. The performance of the two power spectra calculation methods can be compared by simultaneously opening two instances of Raven, one with the Raven 1.3 method active and the other with the Raven 1.2 method active. To compare the two power spectra calculations in Raven: 1. Start Raven 1.3. This instance of Raven 1.3 will continue to use the current method, which in most cases will be the one that was chosen the first time that Raven 1.3 was started. 2. Without closing the first instance of Raven 1.3, start Raven 1.3 again, so that there are now two instances running simultaneously. The second instance will be altered to use whatever method was not chosen the first time that Raven 1.3 was started. 3. With the second instance of Raven 1.3 active, open (from the Windows menu) the Raven preferences file: Start > Programs > Raven 1.3 > RavenPreferences.txt 4. Scroll to the last line of the text, which should read as either: raven.compatibility.computation.spectrogram=1.3 or raven.compatibility.computation.spectrogram=1.2 This statement indicates the power spectra computation method that Raven is currently using.

2 5. Change the version number 1.3 to 1.2, or vice versa. This change will affect only the power spectra computation method. 6. Save and close RavenPreferences.txt 7. Leaving the first instance of Raven 1.3 open, close, then reopen the second instance of Raven The previous preference settings will continue to apply to the first instance of Raven 1.3 as long as it remains open. So, it uses the power spectra computation method that was set previously, while the second instance uses the power spectra computation method that was just set. Using the current Raven 1.3 power spectra calculation in one instance, and the earlier Raven 1.2.x power spectra calculation in the other instance, open the same file in each and view them simultaneously. Clip Exporter within real-time recorder The Clip Exporter in Raven 1.3 allows sound clips to be saved before the audio data in the real-time recorder leaves the audio buffer. This facilitates making manual selections in a recording while it is recording. When a selection is committed, the audio data in the selection is saved to a file. The Clip Exporter is an alternative to the Schedule Tab with the "Record To File" option. The Schedule Tab option allows a recording to be made each time the red record button is pressed, however, the system needs to be configured to do retroactive recording in order to record sounds that are already in the buffer, and the red button needs to be pressed before the end of the retroactive time limit. In contrast, the Clip Exporter allows a selection to be made at any time within the 30-second buffer. Also, the Clip Exporter is similar to Save Active Selection As, however, it allows all of the names that will be assigned to the files to be pre-configured, since there isn t time to fill in this information before the sound leaves the buffer. Exporting samples from various views to text files A list of the numerical sample values contained in the active view of a sound can be exported to a text file. Highlight the view selection button(s) to the left of the view (waveform, spectrogram, etc.) that you want use by double-clicking. The color will change from white to blue when highlighted. Choose File > Export Sound <x> <selected view> Samples. A suggested name, <FileName>.samplesch<cc>.txt, appears, which provides the option of including an updated channel number in the file name of the newly generated file(s). Files can be saved in either Tab-delimited.txt or Commaseparated Value.csv format. To finish, click Save. Saving a subset of channels from an open signal, and Changing the file format Use the Channels window of the Layout view to save a subset of channels from an open signal. Click the area to the right of the check the boxes next to the numbers of the channels that you want to save; the channel numbers will become highlighted in yellow.

3 Then Choose File > Save Selected Channels As. This new method allows an entire channel or channels of data to be saved and replaces the need to create a selection of an entire view. You can choose to Save the new file in a number of different formats: 8-bit, 16-bit, or 24-bit.aiff or 8-bit, 16-bit, or 24-bit.wav. Choose the file type, then click Save. Batch Channels Export To export a specific subset of channels from a collection of sound files, put the collection of files (or copies of the files) in one directory. Then choose Tools > Batch Export Channels. As the Input Folder, enter the name of the directory containing the collection of files you d like to change, then enter the name of the Output Folder in which you want to store the new files. Choose the channels that you would like to export and click OK. Selectable look & feel, and desktop background color The color and texture of the Raven window (the look and feel ) can be selected so that it mimics the appearance of several standard application types, or retains Raven s unique appearance. Choose Window > Look and Feel, and select Metal, Motif, or Windows. Metal is Raven 1.3 s standard appearance. Choose Window > Background Color to open the Background Color Editor panel and set the color of the main Raven screen area (the desktop) through Swatches, HSB, or RGB color definitions. Beamforming view for multi-channel bearing analysis The beamogram plot represents a range of bearing angles in degrees on the y-axis, and time in seconds on the x-axis. The bearing angles calculated for the source signal over time are plotted. To find the bearing angle with the maximum power for a specific selection in Raven, choose the measurement Max Bearing (not to be confused with Maximum bearing, which is a parameter in the Beamforming Bearing Grid). After opening a multi-channel sound file, choose View > New > Beamogram View or choose the icon from the New View Buttons. Then enter the following information in each of the tabbed pages. Choose OK to apply the configuration and close the Configure Beamogram window. Or choose Apply to preview your parameters without closing the window. Medium Sound speed refers to speed of sound within the medium in which the recording was made, usually either air or water. The speed of sound varies in these media based on a number of parameters, including the temperature and density of the media. However, a useful approximate value for the speed of sound in air is 330 meters/second, and in saltwater a useful approximate value is 1500 meters/ second.

4 Array Enter the X and Y locations in the sensor array. One sensor should be designated as a reference. The other sensors should have coordinates that indicate position (in meters) relative to the reference sensor. Filtering If you would like the signal to be bandpass filtered before the beamformer calculation, enter low and high frequency limits to define the bandwidth that will be passed through the filter. Beamforming Time Grid The Record size is the number of samples of sound over which a beam will be computed. The system then hops by the number of samples given in Hop size and repeats the computation. This process is repeated iteratively for all beams. Normalize channels If the gain imbalance between the recorded channels is large, it may become the main information used in the beamformer computation. Therefore, unless the microphones and recording unit are carefully calibrated to produce a uniform gain, normalizing the signal will be useful. Bearing Grid The Minimum bearing and Maximum bearing values (in degrees) define the range over which the series of individual beams will be calculated. It is generally useful to restrict the range to the directional region most likely to contain the source. The Number of bearings is the number of beams that will be computed. A larger number of beams will usually produce a more accurate measurement. The resolution of the beamformer system is defined by the difference between the Maximum bearing and Minimum bearing, divided by the Number of bearings. Bearing Coordinate System When the Reference bearing is set to zero degrees, the array is set to be perpendicular to the sound source. Altering the reference angle alters the orientation of the array to the sensor for the purposes of the beamformer calculation. The rotation of the Bearing Grid that results from altering the reference angle can be specified as either Counterclockwise or Clockwise. View Channels You can create different subsets of channels to use with the beamformer calculation and compare the results. To alter the Beamogram parameters choose View > Beamogram Configuration. Max Bearing Measurement (beamogram view) The Max Bearing is the bearing measurement corresponding to the bin in the beamogram selection that contains the greatest power. Units: degrees

5 The following Measurements have been added from Canary: Average Power The power in the selection divided by the duration of the selection. Units: db Center Frequency Center Time The amplitude-weighted central time of the selected interval. Units: sec Delta Power Energy The total energy in the selection. Units: joules/m 2 Coming Soon Sound Correlation Detection of target signals within a sound. This will include interactive, batch detection in the realtime recorder, which will allow the recorded to record a specific subset of detections. Additional information about extensibility in Raven, related to both audio devices and detectors. Additional documentation.

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. Hello, welcome to Analog Arts spectrum analyzer tutorial. Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. For this presentation, we use a

More information

Getting Started with the LabVIEW Sound and Vibration Toolkit

Getting Started with the LabVIEW Sound and Vibration Toolkit 1 Getting Started with the LabVIEW Sound and Vibration Toolkit This tutorial is designed to introduce you to some of the sound and vibration analysis capabilities in the industry-leading software tool

More information

System Requirements SA0314 Spectrum analyzer:

System Requirements SA0314 Spectrum analyzer: System Requirements SA0314 Spectrum analyzer: System requirements Windows XP, 7, Vista or 8: 1 GHz or faster 32-bit or 64-bit processor 1 GB RAM 10 MB hard disk space \ 1. Getting Started Insert DVD into

More information

CLIPSTER. 3D LUT File Generation with the Kodak Display Manager. Supplement

CLIPSTER. 3D LUT File Generation with the Kodak Display Manager. Supplement Supplement: CLIPSTER 3D LUT File Generation with the Kodak Display Manager (Version 1.0) CLIPSTER 3D LUT File Generation with the Kodak Display Manager Supplement Supplement for the CLIPSTER Documentation:

More information

Fig. 1. The Front Panel (Graphical User Interface)

Fig. 1. The Front Panel (Graphical User Interface) ME 4710 Motion and Control Data Acquisition Software for Step Excitation Introduction o These notes describe LabVIEW software that can be used for data acquisition. The overall software characteristics

More information

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity Print Your Name Print Your Partners' Names Instructions August 31, 2016 Before lab, read

More information

Lab experience 1: Introduction to LabView

Lab experience 1: Introduction to LabView Lab experience 1: Introduction to LabView LabView is software for the real-time acquisition, processing and visualization of measured data. A LabView program is called a Virtual Instrument (VI) because

More information

1 Ver.mob Brief guide

1 Ver.mob Brief guide 1 Ver.mob 14.02.2017 Brief guide 2 Contents Introduction... 3 Main features... 3 Hardware and software requirements... 3 The installation of the program... 3 Description of the main Windows of the program...

More information

Pre-processing of revolution speed data in ArtemiS SUITE 1

Pre-processing of revolution speed data in ArtemiS SUITE 1 03/18 in ArtemiS SUITE 1 Introduction 1 TTL logic 2 Sources of error in pulse data acquisition 3 Processing of trigger signals 5 Revolution speed acquisition with complex pulse patterns 7 Introduction

More information

USB Mini Spectrum Analyzer User s Guide TSA5G35

USB Mini Spectrum Analyzer User s Guide TSA5G35 USB Mini Spectrum Analyzer User s Guide TSA5G35 Triarchy Technologies, Corp. Page 1 of 21 USB Mini Spectrum Analyzer User s Guide Copyright Notice Copyright 2011 Triarchy Technologies, Corp. All rights

More information

Analyzing and Saving a Signal

Analyzing and Saving a Signal Analyzing and Saving a Signal Approximate Time You can complete this exercise in approximately 45 minutes. Background LabVIEW includes a set of Express VIs that help you analyze signals. This chapter teaches

More information

Calibrating the timecode signal input

Calibrating the timecode signal input Chapter 5 Calibrating the timecode signal input Computer hardware can introduce an offset between the timecode signal and the video signal, which causes the timecode and video to be offset when they are

More information

PS User Guide Series Seismic-Data Display

PS User Guide Series Seismic-Data Display PS User Guide Series 2015 Seismic-Data Display Prepared By Choon B. Park, Ph.D. January 2015 Table of Contents Page 1. File 2 2. Data 2 2.1 Resample 3 3. Edit 4 3.1 Export Data 4 3.2 Cut/Append Records

More information

SEM- EDS Instruction Manual

SEM- EDS Instruction Manual SEM- EDS Instruction Manual Double-click on the Spirit icon ( ) on the desktop to start the software program. I. X-ray Functions Access the basic X-ray acquisition, display and analysis functions through

More information

PulseCounter Neutron & Gamma Spectrometry Software Manual

PulseCounter Neutron & Gamma Spectrometry Software Manual PulseCounter Neutron & Gamma Spectrometry Software Manual MAXIMUS ENERGY CORPORATION Written by Dr. Max I. Fomitchev-Zamilov Web: maximus.energy TABLE OF CONTENTS 0. GENERAL INFORMATION 1. DEFAULT SCREEN

More information

Spectrum Analyser Basics

Spectrum Analyser Basics Hands-On Learning Spectrum Analyser Basics Peter D. Hiscocks Syscomp Electronic Design Limited Email: phiscock@ee.ryerson.ca June 28, 2014 Introduction Figure 1: GUI Startup Screen In a previous exercise,

More information

Logic Analyzer Auto Run / Stop Channels / trigger / Measuring Tools Axis control panel Status Display

Logic Analyzer Auto Run / Stop Channels / trigger / Measuring Tools Axis control panel Status Display Logic Analyzer The graphical user interface of the Logic Analyzer fits well into the overall design of the Red Pitaya applications providing the same operating concept. The Logic Analyzer user interface

More information

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 OBJECTIVE To become familiar with state-of-the-art digital data acquisition hardware and software. To explore common data acquisition

More information

Transmitter Interface Program

Transmitter Interface Program Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following

More information

The BAT WAVE ANALYZER project

The BAT WAVE ANALYZER project The BAT WAVE ANALYZER project Conditions of Use The Bat Wave Analyzer program is free for personal use and can be redistributed provided it is not changed in any way, and no fee is requested. The Bat Wave

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

Guide to Analysing Full Spectrum/Frequency Division Bat Calls with Audacity (v.2.0.5) by Thomas Foxley

Guide to Analysing Full Spectrum/Frequency Division Bat Calls with Audacity (v.2.0.5) by Thomas Foxley Guide to Analysing Full Spectrum/Frequency Division Bat Calls with Audacity (v.2.0.5) by Thomas Foxley Contents Getting Started Setting Up the Sound File Noise Removal Finding All the Bat Calls Call Analysis

More information

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors. Brüel & Kjær Pulse Primer University of New South Wales School of Mechanical and Manufacturing Engineering September 2005 Prepared by Michael Skeen and Geoff Lucas NOTICE: This document is for use only

More information

Laboratory 5: DSP - Digital Signal Processing

Laboratory 5: DSP - Digital Signal Processing Laboratory 5: DSP - Digital Signal Processing OBJECTIVES - Familiarize the students with Digital Signal Processing using software tools on the treatment of audio signals. - To study the time domain and

More information

E X P E R I M E N T 1

E X P E R I M E N T 1 E X P E R I M E N T 1 Getting to Know Data Studio Produced by the Physics Staff at Collin College Copyright Collin College Physics Department. All Rights Reserved. University Physics, Exp 1: Getting to

More information

HV/PHA Adjustment (PB) Part

HV/PHA Adjustment (PB) Part HV/PHA Adjustment (PB) Part Contents Contents 1. How to set Part conditions...1 1.1 Setting conditions... 1 2. HV/PHA adjustment sequence...7 3. How to use this Part...9 HV/PHA Adjustment (PB) Part i

More information

Operating Instructions

Operating Instructions Operating Instructions HAEFELY TEST AG KIT Measurement Software Version 1.0 KIT / En Date Version Responsable Changes / Reasons February 2015 1.0 Initial version WARNING Introduction i Before operating

More information

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area. BitWise. Instructions for New Features in ToF-AMS DAQ V2.1 Prepared by Joel Kimmel University of Colorado at Boulder & Aerodyne Research Inc. Last Revised 15-Jun-07 BitWise (V2.1 and later) includes features

More information

Ultra 4K Tool Box. Version Release Note

Ultra 4K Tool Box. Version Release Note Ultra 4K Tool Box Version 2.1.43.0 Release Note This document summarises the enhancements introduced in Version 2.1 of the software for the Omnitek Ultra 4K Tool Box and related products. It also details

More information

Introduction To LabVIEW and the DSP Board

Introduction To LabVIEW and the DSP Board EE-289, DIGITAL SIGNAL PROCESSING LAB November 2005 Introduction To LabVIEW and the DSP Board 1 Overview The purpose of this lab is to familiarize you with the DSP development system by looking at sampling,

More information

Table of Contents. 2 Select camera-lens configuration Select camera and lens type Listbox: Select source image... 8

Table of Contents. 2 Select camera-lens configuration Select camera and lens type Listbox: Select source image... 8 Table of Contents 1 Starting the program 3 1.1 Installation of the program.......................... 3 1.2 Starting the program.............................. 3 1.3 Control button: Load source image......................

More information

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0

Noise. CHEM 411L Instrumental Analysis Laboratory Revision 2.0 CHEM 411L Instrumental Analysis Laboratory Revision 2.0 Noise In this laboratory exercise we will determine the Signal-to-Noise (S/N) ratio for an IR spectrum of Air using a Thermo Nicolet Avatar 360 Fourier

More information

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an.  Kontakt Produkt-Datenblatt Technische Daten, Spezifikationen Kontakt Technischer und kaufmännischer Vertrieb, Preisauskünfte, Angebote, Test-Geräte, Beratung vor Ort: Tel: (0 81 41) 52 71-0 FAX: (0 81 41) 52 71-129

More information

Standard Operating Procedure of nanoir2-s

Standard Operating Procedure of nanoir2-s Standard Operating Procedure of nanoir2-s The Anasys nanoir2 system is the AFM-based nanoscale infrared (IR) spectrometer, which has a patented technique based on photothermal induced resonance (PTIR),

More information

PAMGUARD: An Overview and Gentle Introduction

PAMGUARD: An Overview and Gentle Introduction PAMGUARD: An Overview and Gentle Introduction Preface: PAMGUARD has excellent online, context-sensitive help which can be called upon from any part of the program. This is updated as the program develops

More information

HEAD. HEAD VISOR (Code 7500ff) Overview. Features. System for online localization of sound sources in real time

HEAD. HEAD VISOR (Code 7500ff) Overview. Features. System for online localization of sound sources in real time HEAD Ebertstraße 30a 52134 Herzogenrath Tel.: +49 2407 577-0 Fax: +49 2407 577-99 email: info@head-acoustics.de Web: www.head-acoustics.de Data Datenblatt Sheet HEAD VISOR (Code 7500ff) System for online

More information

PYROPTIX TM IMAGE PROCESSING SOFTWARE

PYROPTIX TM IMAGE PROCESSING SOFTWARE Innovative Technologies for Maximum Efficiency PYROPTIX TM IMAGE PROCESSING SOFTWARE V1.0 SOFTWARE GUIDE 2017 Enertechnix Inc. PyrOptix Image Processing Software v1.0 Section Index 1. Software Overview...

More information

Silver Mountain Targets V2 Software Reference Guide. July 22, 2015

Silver Mountain Targets V2 Software Reference Guide. July 22, 2015 Silver Mountain Targets V2 Software Reference Guide July 22, 2015 1. Setting up new targets for the first time If this is the first time using the e-targets on a target frame, you will need to create and

More information

Overview. Signal Averaged ECG

Overview. Signal Averaged ECG Updated 06.09.11 : Signal Averaged ECG Overview Signal Averaged ECG The Biopac Student Lab System can be used to amplify and enhance the ECG signal using a clinical diagnosis tool referred to as the Signal

More information

Lab 1 Introduction to the Software Development Environment and Signal Sampling

Lab 1 Introduction to the Software Development Environment and Signal Sampling ECEn 487 Digital Signal Processing Laboratory Lab 1 Introduction to the Software Development Environment and Signal Sampling Due Dates This is a three week lab. All TA check off must be completed before

More information

CF-4700 FFT Comparator Comparator Setting Operation

CF-4700 FFT Comparator Comparator Setting Operation CF-4700 FFT Comparator Comparator Setting Operation -Contents- 1. Block comparator 2. Shape comparator (Time-axis waveform) 3. Tracking waveform shape comparator 2 Overview of the Comparator Function CF-4700

More information

A Matlab toolbox for. Characterisation Of Recorded Underwater Sound (CHORUS) USER S GUIDE

A Matlab toolbox for. Characterisation Of Recorded Underwater Sound (CHORUS) USER S GUIDE Centre for Marine Science and Technology A Matlab toolbox for Characterisation Of Recorded Underwater Sound (CHORUS) USER S GUIDE Version 5.0b Prepared for: Centre for Marine Science and Technology Prepared

More information

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad. Getting Started First thing you should do is to connect your iphone or ipad to SpikerBox with a green smartphone cable. Green cable comes with designators on each end of the cable ( Smartphone and SpikerBox

More information

Session 1 Introduction to Data Acquisition and Real-Time Control

Session 1 Introduction to Data Acquisition and Real-Time Control EE-371 CONTROL SYSTEMS LABORATORY Session 1 Introduction to Data Acquisition and Real-Time Control Purpose The objectives of this session are To gain familiarity with the MultiQ3 board and WinCon software.

More information

Torsional vibration analysis in ArtemiS SUITE 1

Torsional vibration analysis in ArtemiS SUITE 1 02/18 in ArtemiS SUITE 1 Introduction 1 Revolution speed information as a separate analog channel 1 Revolution speed information as a digital pulse channel 2 Proceeding and general notes 3 Application

More information

B I O E N / Biological Signals & Data Acquisition

B I O E N / Biological Signals & Data Acquisition B I O E N 4 6 8 / 5 6 8 Lectures 1-2 Analog to Conversion Binary numbers Biological Signals & Data Acquisition In order to extract the information that may be crucial to understand a particular biological

More information

Cisco Spectrum Expert Software Overview

Cisco Spectrum Expert Software Overview CHAPTER 5 If your computer has an 802.11 interface, it should be enabled in order to detect Wi-Fi devices. If you are connected to an AP or ad-hoc network through the 802.11 interface, you will occasionally

More information

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1

USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1 USB Mini Spectrum Analyzer User Manual TSA Program for PC TSA4G1 TSA6G1 TSA8G1 Triarchy Technologies Corp. Page 1 of 17 USB Mini Spectrum Analyzer User Manual Copyright Notice Copyright 2013 Triarchy Technologies,

More information

Spike Spectrum Analyzer Software User Manual

Spike Spectrum Analyzer Software User Manual TM Spike Spectrum Analyzer Software User Manual Spike TM Spectrum Analyzer Software User Manual 2015, Signal Hound, Inc. 35707 NE 86th Ave La Center, WA 98629 USA Phone 360.263.5006 Fax 360.263.5007 ii

More information

User s Manual. Log Scale (/LG) GX10/GX20/GP10/GP20/GM10 IM 04L51B01-06EN. 3rd Edition

User s Manual. Log Scale (/LG) GX10/GX20/GP10/GP20/GM10 IM 04L51B01-06EN. 3rd Edition User s Manual Model GX10/GX20/GP10/GP20/GM10 Log Scale (/LG) 3rd Edition Introduction Thank you for purchasing the SMARTDAC+ Series GX10/GX20/GP10/GP20/GM10 (hereafter referred to as the recorder, GX,

More information

Quick Start Guide. Multidimensional Imaging

Quick Start Guide. Multidimensional Imaging Quick Start Guide Multidimensional Imaging Printed 11/2012 Multidimensional Imaging Content Quick Start Guide Content 1 Introduction 4 2 Set up multi-channel experiments 5 2.1 Set up a new experiment

More information

FSK Transmitter/Receiver Simulation Using AWR VSS

FSK Transmitter/Receiver Simulation Using AWR VSS FSK Transmitter/Receiver Simulation Using AWR VSS Developed using AWR Design Environment 9b This assignment uses the AWR VSS project titled TX_RX_FSK_9_91.emp which can be found on the MUSE website. It

More information

Source/Receiver (SR) Setup

Source/Receiver (SR) Setup PS User Guide Series 2015 Source/Receiver (SR) Setup For 1-D and 2-D Vs Profiling Prepared By Choon B. Park, Ph.D. January 2015 Table of Contents Page 1. Overview 2 2. Source/Receiver (SR) Setup Main Menu

More information

Using EndNote Web. University of Otago Library.

Using EndNote Web. University of Otago Library. Using EndNote Web University of Otago Library www.library.otago.ac.nz/endnote November 2011 1 Contents Using EndNote Web... 3 Setting up the Connection... 4 Transferring References between Desktop and

More information

VISSIM Tutorial. Starting VISSIM and Opening a File CE 474 8/31/06

VISSIM Tutorial. Starting VISSIM and Opening a File CE 474 8/31/06 VISSIM Tutorial Starting VISSIM and Opening a File Click on the Windows START button, go to the All Programs menu and find the PTV_Vision directory. Start VISSIM by selecting the executable file. The following

More information

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5

USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5 USB Mini Spectrum Analyzer User Manual PC program TSA For TSA5G35 TSA4G1 TSA6G1 TSA12G5 Triarchy Technologies, Corp. Page 1 of 17 USB Mini Spectrum Analyzer User Manual Copyright Notice Copyright 2013

More information

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN This spreadsheet has been created to help design a protocol before actually entering the parameters into the Espion software. It details all the protocol parameters

More information

Tektronix RSA306 USB Spectrum Analyzer

Tektronix RSA306 USB Spectrum Analyzer Tektronix RSA306 USB Spectrum Analyzer Simple Demos The Demo of the RSA306 is easy. Even you do not have signal generators, devices under test, or demo boards, using the whip antenna provided in box, you

More information

Patchmaster. Elektronik. The Pulse generator. February 2013

Patchmaster. Elektronik. The Pulse generator. February 2013 Patchmaster The Pulse generator Elektronik Telly Galiatsatos, BS 1987: Graduated at Queens College, NY Computer Science 1987-2007: Instrutech Corporation IT Engineering Support Software Engineer, Sales

More information

Using different reference quantities in ArtemiS SUITE

Using different reference quantities in ArtemiS SUITE 06/17 in ArtemiS SUITE ArtemiS SUITE allows you to perform sound analyses versus a number of different reference quantities. Many analyses are calculated and displayed versus time, such as Level vs. Time,

More information

SigPlay User s Guide

SigPlay User s Guide SigPlay User s Guide . . SigPlay32 User's Guide? Version 3.4 Copyright? 2001 TDT. All rights reserved. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or

More information

Processing data with Mestrelab Mnova

Processing data with Mestrelab Mnova Processing data with Mestrelab Mnova This exercise has three parts: a 1D 1 H spectrum to baseline correct, integrate, peak-pick, and plot; a 2D spectrum to plot with a 1 H spectrum as a projection; and

More information

SNG-2150C User s Guide

SNG-2150C User s Guide SNG-2150C User s Guide Avcom of Virginia SNG-2150C User s Guide 7730 Whitepine Road Revision 001 Richmond, VA 23237 USA GENERAL SAFETY If one or more components of your earth station are connected to 120

More information

Practicum 3, Fall 2010

Practicum 3, Fall 2010 A. F. Miller 2010 T1 Measurement 1 Practicum 3, Fall 2010 Measuring the longitudinal relaxation time: T1. Strychnine, dissolved CDCl3 The T1 is the characteristic time of relaxation of Z magnetization

More information

Contents. 1. System Description 3. Overview 3 Part Names 3 Operating Conditions 7 Start-up Procedure 7. 2.

Contents. 1. System Description 3. Overview 3 Part Names 3 Operating Conditions 7 Start-up Procedure 7. 2. Rigel 1550 Terahertz Spectrometer User Manual Contents info@tetechs.com 1. System Description 3 Overview 3 Part Names 3 Operating Conditions 7 Start-up Procedure 7 2. Safety 9 Laser Safety 9 Electrical

More information

Capstone Experiment Setups & Procedures PHYS 1111L/2211L

Capstone Experiment Setups & Procedures PHYS 1111L/2211L Capstone Experiment Setups & Procedures PHYS 1111L/2211L Picket Fence 1. Plug the photogate into port 1 of DIGITAL INPUTS on the 850 interface box. Setup icon. the 850 box. Click on the port 1 plug in

More information

Activity P27: Speed of Sound in Air (Sound Sensor)

Activity P27: Speed of Sound in Air (Sound Sensor) Activity P27: Speed of Sound in Air (Sound Sensor) Concept DataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win) Speed of sound P27 Speed of Sound 1.DS (See end of activity) (See end of activity) Equipment

More information

Matrox PowerStream Plus

Matrox PowerStream Plus Matrox PowerStream Plus User Guide 20246-301-0100 2016.12.01 Contents 1 About this user guide...5 1.1 Using this guide... 5 1.2 More information... 5 2 Matrox PowerStream Plus software...6 2.1 Before you

More information

Import and quantification of a micro titer plate image

Import and quantification of a micro titer plate image BioNumerics Tutorial: Import and quantification of a micro titer plate image 1 Aims BioNumerics can import character type data from TIFF images. This happens by quantification of the color intensity and/or

More information

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera

BEAMAGE 3.0 KEY FEATURES BEAM DIAGNOSTICS PRELIMINARY AVAILABLE MODEL MAIN FUNCTIONS. CMOS Beam Profiling Camera PRELIMINARY POWER DETECTORS ENERGY DETECTORS MONITORS SPECIAL PRODUCTS OEM DETECTORS THZ DETECTORS PHOTO DETECTORS HIGH POWER DETECTORS CMOS Beam Profiling Camera AVAILABLE MODEL Beamage 3.0 (⅔ in CMOS

More information

Analyzing Modulated Signals with the V93000 Signal Analyzer Tool. Joe Kelly, Verigy, Inc.

Analyzing Modulated Signals with the V93000 Signal Analyzer Tool. Joe Kelly, Verigy, Inc. Analyzing Modulated Signals with the V93000 Signal Analyzer Tool Joe Kelly, Verigy, Inc. Abstract The Signal Analyzer Tool contained within the SmarTest software on the V93000 is a versatile graphical

More information

LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution. A. Plotting a GM Plateau. This lab will have two sections, A and B.

LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution. A. Plotting a GM Plateau. This lab will have two sections, A and B. LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution This lab will have two sections, A and B. Students are supposed to write separate lab reports on section A and B, and submit the

More information

Topic: Instructional David G. Thomas December 23, 2015

Topic: Instructional David G. Thomas December 23, 2015 Procedure to Setup a 3ɸ Linear Motor This is a guide to configure a 3ɸ linear motor using either analog or digital encoder feedback with an Elmo Gold Line drive. Topic: Instructional David G. Thomas December

More information

Quick Reference Manual

Quick Reference Manual Quick Reference Manual V1.0 1 Contents 1.0 PRODUCT INTRODUCTION...3 2.0 SYSTEM REQUIREMENTS...5 3.0 INSTALLING PDF-D FLEXRAY PROTOCOL ANALYSIS SOFTWARE...5 4.0 CONNECTING TO AN OSCILLOSCOPE...6 5.0 CONFIGURE

More information

MDF Exporter This new function allows output in the ASAM MDF 4.0 file format, which is now widely used in the auto industry. Data import from the DS-3000 series Data Station Recorded data is transferred

More information

EASERA SysTune. Developed by. AFMG Ahnert Feistel Media Group. The creators of EASE and EASERA.

EASERA SysTune. Developed by. AFMG Ahnert Feistel Media Group. The creators of EASE and EASERA. EASERA SysTune - Developed by AFMG Ahnert Feistel Media Group The creators of EASE and EASERA www.afmg.eu Software Manual,, December 2007 Copyright 2006-2007 SDA Software Design Ahnert GmbH Contents -

More information

VISSIM TUTORIALS This document includes tutorials that provide help in using VISSIM to accomplish the six tasks listed in the table below.

VISSIM TUTORIALS This document includes tutorials that provide help in using VISSIM to accomplish the six tasks listed in the table below. VISSIM TUTORIALS This document includes tutorials that provide help in using VISSIM to accomplish the six tasks listed in the table below. Number Title Page Number 1 Adding actuated signal control to an

More information

Virtual Vibration Analyzer

Virtual Vibration Analyzer Virtual Vibration Analyzer Vibration/industrial systems LabVIEW DAQ by Ricardo Jaramillo, Manager, Ricardo Jaramillo y Cía; Daniel Jaramillo, Engineering Assistant, Ricardo Jaramillo y Cía The Challenge:

More information

EndNote X7 Getting Started. (adapted with permission from Thompson 2006)

EndNote X7 Getting Started. (adapted with permission from Thompson 2006) EndNote X7 Getting Started (adapted with permission from Thompson 2006) August 2013 Content 1. Introduction... 3 1.1 Finding Your Way Around EndNote... 3 2. Creating & Adding Records To Your EndNote Library...

More information

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio

Interface Practices Subcommittee SCTE STANDARD SCTE Measurement Procedure for Noise Power Ratio Interface Practices Subcommittee SCTE STANDARD SCTE 119 2018 Measurement Procedure for Noise Power Ratio NOTICE The Society of Cable Telecommunications Engineers (SCTE) / International Society of Broadband

More information

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display. Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display. Your Stack ST8961 VS module allows you to synchronize, overlay, and record data available on your Stack

More information

MTL Software. Overview

MTL Software. Overview MTL Software Overview MTL Windows Control software requires a 2350 controller and together - offer a highly integrated solution to the needs of mechanical tensile, compression and fatigue testing. MTL

More information

Major Differences Between the DT9847 Series Modules

Major Differences Between the DT9847 Series Modules DT9847 Series Dynamic Signal Analyzer for USB With Low THD and Wide Dynamic Range The DT9847 Series are high-accuracy, dynamic signal acquisition modules designed for sound and vibration applications.

More information

MultiSpec Tutorial: Visualizing Growing Degree Day (GDD) Images. In this tutorial, the MultiSpec image processing software will be used to:

MultiSpec Tutorial: Visualizing Growing Degree Day (GDD) Images. In this tutorial, the MultiSpec image processing software will be used to: MultiSpec Tutorial: Background: This tutorial illustrates how MultiSpec can me used for handling and analysis of general geospatial images. The image data used in this example is not multispectral data

More information

DIGITAL PERSONAL STUDIO Version 1.30 Addendum

DIGITAL PERSONAL STUDIO Version 1.30 Addendum DIGITAL PERSONAL STUDIO Version 1.30 Addendum Contents V1.30 FEATURES...1 AK.SYS TRACKVIEW...2 INSTALLING AK.SYS TRACKVIEW...2 USING AK.SYS TRACKVIEW...3 METERS...4 IN / OUT TIMES...5 TIMECODE DISPLAY...5

More information

127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) (800) (бесплатно на территории России)

127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) (800) (бесплатно на территории России) 127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) 322-99-34 +7 (800) 200-74-93 (бесплатно на территории России) E-mail: info@awt.ru, web:www.awt.ru Contents 1 Introduction...2

More information

AFMG SysTune. Developed by. AFMG Ahnert Feistel Media Group. The creators of EASE and EASERA

AFMG SysTune. Developed by. AFMG Ahnert Feistel Media Group. The creators of EASE and EASERA AFMG SysTune - Developed by AFMG Ahnert Feistel Media Group The creators of EASE and EASERA www.afmg.eu Software Manual, Rev. 5, May 2014 Copyright 2006-2014 AFMG Technologies GmbH - Contents Contents

More information

Matrox PowerStream Plus

Matrox PowerStream Plus Matrox PowerStream Plus User Guide 20246-301-0200 2017.07.04 Contents 1 About this user guide... 5 1.1 Using this guide... 5 1.2 More information... 5 2 Matrox PowerStream Plus software... 6 2.1 Before

More information

D-Lab & D-Lab Control Plan. Measure. Analyse. User Manual

D-Lab & D-Lab Control Plan. Measure. Analyse. User Manual D-Lab & D-Lab Control Plan. Measure. Analyse User Manual Valid for D-Lab Versions 2.0 and 2.1 September 2011 Contents Contents 1 Initial Steps... 6 1.1 Scope of Supply... 6 1.1.1 Optional Upgrades... 6

More information

Supplementary Course Notes: Continuous vs. Discrete (Analog vs. Digital) Representation of Information

Supplementary Course Notes: Continuous vs. Discrete (Analog vs. Digital) Representation of Information Supplementary Course Notes: Continuous vs. Discrete (Analog vs. Digital) Representation of Information Introduction to Engineering in Medicine and Biology ECEN 1001 Richard Mihran In the first supplementary

More information

Part 1: Introduction to Computer Graphics

Part 1: Introduction to Computer Graphics Part 1: Introduction to Computer Graphics 1. Define computer graphics? The branch of science and technology concerned with methods and techniques for converting data to or from visual presentation using

More information

JAMAR TRAX RD Detector Package Power Requirements Installation Setting Up The Unit

JAMAR TRAX RD Detector Package Power Requirements Installation Setting Up The Unit JAMAR TRAX RD The TRAX RD is an automatic traffic recorder designed and built by JAMAR Technologies, Inc. Since the unit is a Raw Data unit, it records a time stamp of every sensor hit that occurs during

More information

Department of Electrical & Electronic Engineering Imperial College of Science, Technology and Medicine. Project: Real-Time Speech Enhancement

Department of Electrical & Electronic Engineering Imperial College of Science, Technology and Medicine. Project: Real-Time Speech Enhancement Department of Electrical & Electronic Engineering Imperial College of Science, Technology and Medicine Project: Real-Time Speech Enhancement Introduction Telephones are increasingly being used in noisy

More information

Dektak Step by Step Instructions:

Dektak Step by Step Instructions: Dektak Step by Step Instructions: Before Using the Equipment SIGN IN THE LOG BOOK Part 1: Setup 1. Turn on the switch at the back of the dektak machine. Then start up the computer. 2. Place the sample

More information

Analog Discovery Scope and Waveform Generator Edited 11/15/2016 by Eric Scotti & DGH

Analog Discovery Scope and Waveform Generator Edited 11/15/2016 by Eric Scotti & DGH Analog Discovery Scope and Waveform Generator Edited 11/15/2016 by Eric Scotti & DGH Specifications The Analog Discovery contains several devices but we will likely only use the 2 channel oscilloscope

More information

Universal Mode. Survey Settings. The Universal Toolbar. First Run - Initial Configuration via the Setup Button

Universal Mode. Survey Settings. The Universal Toolbar. First Run - Initial Configuration via the Setup Button Universal Mode The Universal Toolbar The Universal Toolbar is the unified (and preferred) method of operating Revolution. From within the Universal Toobar, all functionality of the other 3 modes of Revolution

More information

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

Cover Page for Lab Report Group Portion. Boundary Layer Measurements Cover Page for Lab Report Group Portion Boundary Layer Measurements Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 23 February 2017 Name 1: Name 2: Name 3: [Name 4: ] Date:

More information

Sound Insulation Reporter

Sound Insulation Reporter Sound Insulation Reporter for XL2 Sound Level Meter V1.28.00 www.nti-audio.com Jul 18, Page 1 / 58 Index 1. Introduction...3 2. Standards...4 3. My First Steps...5 Software Installation... 5 Additional

More information

Synchronization Check Relay ARGUS 7

Synchronization Check Relay ARGUS 7 Synchronization Check Relay ARGUS 7 Page 1 of 8 Table of Contents Secondary injection tests:... 3 Phase Angle Test:... 3 CS PHASE ANGLE:... 3 SS PHASE ANGLE:... 3 SLIP FREQUENCY TEST:... 4 CS SLIP FREQUENCY:...

More information

Class Notes for Cite While You Write Basics. EndNote Training

Class Notes for Cite While You Write Basics. EndNote Training Class Notes for Cite While You Write Basics EndNote Training EndNote X8 Class Notes for Cite While You Write Basics 1 January 3, 2017 Your EndNote data, both on the desktop and online, can be used in Microsoft

More information