Photometric Test Report

Size: px
Start display at page:

Download "Photometric Test Report"

Transcription

1 Photometric Test Report Relevant Standards IES LM ANSI C UL Prepared For Mercury Lighting Stephen Bambush 20 Audrey Pl. Fairfield, NJ Catalog Number LW K-HTA-S50-UNI-XXXX Order Number Test Number Test Date Prepared By Approved By Jeff Smith Jr., Project Handler Kyle Spaziani, Project Handler The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Underwriters Laboratories. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Test Number Page 1 of 8

2 Table of Contents Integrating Sphere Results Page 3 Page 4 Distribution Results Conditions / / Polar Plot / Zonal / Luminance Candela Tabulation Coefficients of Utilization Page 5 Page 5 Page 6 Page 7 In-Situ Results Page 8 Requirement Category Minimum Light Output Minimum Lamp Output Spacing Criteria (0-180 ) Spacing Criteria ( ) Zonal Lumen Requirement (0-60 ) Zonal Lumen Requirement 2 Minimum Luminaire Efficacy Minimum Lamp Efficacy Alowable CCTs* Minimum CRI L70 Lumen maintenance Minimum Luminaire Warranty Power Factor 120 / 277 Total Harmonic Distortion (A-%) DLC Results Summary Technical Requirements v2.1 Linear Ambient Luminaires: Direct Requirement Test Results Lumens/ft % 77.9% lm/w 79.4 lm/w 5000K 3076 K Hours TM-21 must be completed 5 Years % 7.595% *Defined by ANSI C ǂ ǂANSI C also referred to for Duv and (x,y) chromaticity coordinates tolerances for indoor categories Laboratory results may not be representative of field performance Ballast factors have not been applied Testing was performed in a 2-meter integrating sphere using the 4π geometry method. Absorption correction was employed for Sphere measurement Test Number Page 2 of 8

3 Luminaire Description: Lamp: Mounting: Ballast/Driver: Formed white enamel steel housing, white enamel steel reflector, frosted plastic lens enclosure 120 white LEDs Surface One Osram Optotronic OT50W/PRG1400C/UNV/DIM/L Luminaire Luminaire Characteristics Luminous Length: in. Luminous Width: in. Integrating Sphere Distribution Luminous Flux: Efficacy: CCT: 4547 Lumens 82.0 lm/w 3076 K Total Luminaire Output: Luminaire Efficacy: Maximum Candela: CRI (Ra): Lumens 79.4 lm/w 1544 Candela Electrical Data at 120 VAC In-Situ Test Temperature: 24.9 C LED Temperature: 81.6 C Voltage: VAC Driver Temperature: 75.6 C Current: A Maximum LED Current: A Power: Power Factor: W Frequency: 60 Hz Temperatures are offset to an ambient temperature of 25 C Current THD: 7.68 % as described in UL Test Number Page 3 of 8

4 Spectral Flux (mw/nm) Color Quality - Integrating Sphere Integrating Sphere Test Conditions Temperature Voltage Current Power Power Factor Frequency Current THD 24.9 C VAC A W Hz 7.68 % Luminous Flux 4547 Lumens Efficacy: 82.0 lm/w CCT: 3076 K CRI (Ra): 82.9 CRI (R9): 21.4 Chromaticity (x) Chromaticity (y) Chromaticity (u) Chromaticity (v) Chromaticity (u' Chromaticity (v') Duv: Insert Chromaticity Diagram Flux vs Wavelength Wavelength (nm) Test Number Page 4 of 8

5 Distribution - Goniophotometer Distribution Test Conditions Temperature Voltage Current Power Power Factor Frequency Current THD 25.0 C VAC A W Hz 7.60 % Spacing Criteria Total Lumen Output: 0-180: 1.20 Luminaire Efficacy: : 1.30 Maximum Candela: 4410 Lumens 79.4 lm/w 1544 Candela Polar Plot Deg. Plane 270 Deg. Plane 0 Deg. Plane 90 Deg. Plane Zonal Lumen Summary Zone Lumens % of Luminaire Zone Lumens % of Luminaire Zone Lumens % of Luminaire % % % % % % % % % % % % % % % % % % % Test Number Page 5 of 8

6 Vertical Angle (Degrees) Vertical Angle (Degrees) Candela Tabulation Horizontal Angle (Degrees) Average Luminance (cd/m 2 ) Horizontal Angle (Degrees) Test Number Page 6 of 8

7 Ceiling Cavity Reflectance Wall Reflectance Room Cavity Ratio (RCR) Utilization of Lumens - Zonal Cavity Method Effective Floor Cavity Reflectance 20% ** Values are expressed as Lumens delivered to the task surface ** Cone of Light Tabulation Mounting Footcandles Diameter Height at Nadir (Feet) Cone of Light Plot Test Number Page 7 of 8

8 In-Situ Test In-Situ Test Conditions Temperature Voltage Current Power Power Factor Frequency Current THD 23.0 C VAC N / A N / A N / A 60 Hz N / A LED Temperature: Driver Temperature: Maximum LED Current: 81.6 C 75.6 C A Temperatures are offset to an ambient temperature of 25 C as described in UL LED Temperature Location Driver Temperature Location Test Number Page 8 of 8

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For MaxLite, Inc 12 York Ave, West Caldwell, NJ07006, USA Penny Li, pli@maxlite.com, 021-67286918-815

More information

Report of Test LLIA A-R01*

Report of Test LLIA A-R01* Report of Test LLIA000849-001A-R01* *This test report supersedes test report LLIA000849-001A One Osram Optotronic OTi 30/120-277/1A0 DIM L LED driver. Total Light Output Luminaire Power Luminous Efficacy

More information

PHONE: (303) FAX: (970) WEBSITE:

PHONE: (303) FAX: (970) WEBSITE: REPORT NUMBER: ITL82327 PAGE: 1 OF 5 LUMINAIRE: FABRICATED METAL HOUSING WITH WHITE PAINTED INTERIOR FINISH, FORMED WHITE PAINTED METAL DRIVER COVER, 4 WHITE CIRCUIT BOARDS EACH WITH 32 LEDS, CLEAR FLAT

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB01237 PAGE: 1 OF 5 LUMINAIRE: FABRICATED WHITE PAINTED METAL HOUSING, 2 WHITE CIRCUIT BOARDS EACH WITH 120 LEDS, FROSTED HOLOGRAPHIC PLASTIC LENS. LENS FROSTED SIDE UP. LAMP: TWO HUNDRED

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB01231 PAGE: 1 OF 5 LUMINAIRE: FABRICATED WHITE PAINTED METAL HOUSING, 2 WHITE CIRCUIT BOARDS EACH WITH 120 LEDS, FROSTED HOLOGRAPHIC PLASTIC DIFFUSER. DIFFUSER FROSTED SIDE UP. LAMP:

More information

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

Osram Sylvania 200 Ballardvale Street Wilmington, Mass Report No: L011506002 Date: 1/26/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L011506002 Report Prepared For: Osram Sylvania 200 Ballardvale

More information

Fixture is tested with no special conditions. No seasoning was performed in accordance with IESNA LM-79. PS-AC02 CD-SN03-S2 MT-SC01-S2 2MR97 SPR-3000

Fixture is tested with no special conditions. No seasoning was performed in accordance with IESNA LM-79. PS-AC02 CD-SN03-S2 MT-SC01-S2 2MR97 SPR-3000 Report No: L031602602 Date: 3/10/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L031602602 Report Prepared For: Osram Sylvania, Inc. Model

More information

ZipTwo LED - Zipper board with Diffuse Batwing Lens, High Output. IES File Performance Summary

ZipTwo LED - Zipper board with Diffuse Batwing Lens, High Output. IES File Performance Summary Adaptive architectural lighting systems IES File Performance Summary The performance data in black text are confirmed through third party testing. See the following Light Laboratory report for details.

More information

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Fuel Pump Canopy Luminaires

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Fuel Pump Canopy Luminaires LM-79-08 Test Report For GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China Fuel Pump Canopy Luminaires Model name(s):33-cp1-760-8xx

More information

Bartco Lighting 5761 Research Drive, Huntington Beach, CA

Bartco Lighting 5761 Research Drive, Huntington Beach, CA Report No: L051706901 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L051706901 Issue Date: 5/24/2017 Report Prepared For: Bartco Lighting 5761 Research Drive, Huntington Beach,

More information

Number Eight Lighting Company 526 Portal Street, Cotati, CA 94931

Number Eight Lighting Company 526 Portal Street, Cotati, CA 94931 Report No: L101605125 Date: 12/8/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com NVLAP LAB CODE 200927-0 Report No: L101605125 Report Prepared For: Number Eight Lighting Company 526

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8087E40-A LED-8087M40-A Remark : The suffix of the model name E stand

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL07695-001A OSQ-A-xx-WSN-U-30K-ULxxxxx Date: 4/1/2016 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8087E57C-A LED-8087M57C-A Remark : The suffix of the model name E stand

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 500077-0 Report Number: Model: PL10259-001A ZR24RK-50L-35K-10V-FD Date: 03/02/2017 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared

More information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 Project No. G102959372 Date: March 17, 2017 REPORT NO. 102959372CRT-001 TEST OF ONE LINEAR LED FIXTURE MODEL NO. K81400 F 10 44 W3 N N LED MODEL NO. OSRAM

More information

PHONE: (303) FAX: (970) WEBSITE:

PHONE: (303) FAX: (970) WEBSITE: REPORT NUMBER: ITL REPORT NUMBER PAGE: 1 OF 7 ADDRESS: 123 THE RIGHT WAY ANYTOWN, CO 80503 LUMINAIRE: FABRICATED METAL HOUSING, WHITE PAINTED INTERIOR FINISH, FABRICATED SEMI-SPECULAR METAL PARABOLIC 12-CELL

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

NVLAP LAB CODE LM Test Report. For. EiKO Global, LLC. (Brand Name: EiKO) W. 84th St, Shawnee, KS USA

NVLAP LAB CODE LM Test Report. For. EiKO Global, LLC. (Brand Name: EiKO) W. 84th St, Shawnee, KS USA LM-79-08 Test Report For EiKO Global, LLC (Brand Name: EiKO) 23220 W. 84th St, Shawnee, KS 66227 USA Outdoor Non-Cutoff and Semi-Cutoff Wallmounted Area Luminaires Model name(s): WMG-2C-50K-U Representative

More information

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada LM-79-08 Test Report For CE INNOVATIONS LTD (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada 2x4 Luminaires for Ambient Lighting of Interior Commercial Spaces Model name(s): IR-P7-50W2B45500LM

More information

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) LM-79-08 Test Report For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A) 7 F,Jinchangda Industrial Park,zhangkengjing,GuanLan, Baoao,Shenzhen,Guangdong,China 2x4 Luminaires for Ambient Lighting of Interior

More information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 1345 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 142-.. Project No. G1258525 Date: May 26, 216 REPORT NO. 1258524CRT-1 TEST OF ONE LED TRACK LUMINAIRE

More information

Revolution Lighting Technologies (RVLT) 2280 Ward Ave. Docks 5&6, Simi Valley, CA 93065

Revolution Lighting Technologies (RVLT) 2280 Ward Ave. Docks 5&6, Simi Valley, CA 93065 Report No: L051704002 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L051704002 Issue Date: 5/16/2017 Report Prepared For: Revolution Lighting Technologies (RVLT) 2280 Ward Ave.

More information

Number Eight Lighting Company 803/K2-HI-25-XX/DIM /FS-P-1-WH

Number Eight Lighting Company 803/K2-HI-25-XX/DIM /FS-P-1-WH Report No: L101605126 Date: 12/8/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L101605126 Number Eight Lighting

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 1345 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 142-.. Project No. G1258525 Date: May 27, 216 REPORT NO. 1258524CRT-2 TEST OF ONE LED TRACK LUMINAIRE

More information

Infinilux 5349 Zambrano St, Commerce, CA Electrical and Photometric tests as required by the IESNA test standards.

Infinilux 5349 Zambrano St, Commerce, CA Electrical and Photometric tests as required by the IESNA test standards. Test #: L03130308 Date: 3/12/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L03130308 CLSPXX36 Report Prepared For: Infinilux

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA000536-002 Integrating Sphere Report Performance Summary Voltage Current Power Frequency Power Factor Current THD Total Luminous Flux Efficacy Chromaticity (x,y) (u',v') Duv CCT CRI

More information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. Project No. G102714629 Issue Date: August 31, 2016 REPORT NO. 102714629CRT-003 TEST OF

More information

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS 71346 LED Floodlight RoHS OVERALL LAMP PARAMETERS LED DRIVER LED Model: Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output Voltage Output

More information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 1345 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 142-.. Project No. G11346762 REPORT NO. 11346762CRT-1 TEST OF ONE LED AREA LIGHT MODEL NO. GC228LEDGV133W

More information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 1345 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 142-.. Project No. G11178928 Date: July 29, 213 REPORT NO. 11178928CRT-4 TEST OF ONE LED LINE VOLTAGE

More information

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Project No. G100508854 Date: November 2, 2011 REPORT NO. 100508854CRT-001A TEST OF ONE LED

More information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 1345 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 142-.. Project No. G11178928 Date: July 3, 213 REPORT NO. 11178928CRT-3 TEST OF ONE LED LINE VOLTAGE

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 17025:2005. Project No. G101589308 Date: April 3, 2014 REPORT NO. 101589308LAX-023 TEST OF ONE

More information

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE 100402-0. Project No. G100896445 Date: September 26, 2012 REPORT NO. 100896445CRT-002 TEST OF ONE LED

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 258 COMMERCENTRE DRIVE, LAKE FOREST, CA 9263 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 1725:25. Project No. G1167677 Date: April 29, 214 REPORT NO. 1167677LAX-1 TEST OF ONE DYNAMIC WHITE

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 258 COMMERCENTRE DRIVE, LAKE FOREST, CA 9263 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 1725:25. Project No. G1158938 Date: April 2, 214 REPORT NO. 1158938LAX-25 TEST OF ONE TVL 2 II WW

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 258 COMMERCENTRE DRIVE, LAKE FOREST, CA 9263 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 1725:25. Project No. G1158938 Date: April 2, 214 REPORT NO. 1158938LAX-1 TEST OF ONE LEVEL Q7 (IP)

More information

LM - 79 Reporting. Laboratory Information. Date of test report July 31 st, Product Information

LM - 79 Reporting. Laboratory Information. Date of test report July 31 st, Product Information LM - 79 Reporting Laboratory Information Name of test lab Intertek Date of test report July 31 st, 2013 Test report number 101235726CRT-006 Laboratory contact name Vladimir Kozak Product Information Manufacturer

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 17025:2005. Project No. G101589308 Date:April 2, 2014 REPORT NO. 101589308LAX-016 TEST OF ONE

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 1725:25. REPORT 258 COMMERCENTRE DRIVE, LAKE FOREST, CA 9263 Project No. G1167677 Date: April 29, 21 REPORT NO. 1167677LAX-5 TEST OF ONE DYNAMIC WHITE

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 . REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G103405222 Date: February 15, 2018 REPORT NO. 103405222LA-001 TEST OF ONE ASYMETRIC LED MODEL NO. AS1- LED- H- 35K- 4 LED MODEL NO.

More information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 REPORT 545 E. Algonquin Rd., Arlington Heights, IL 65 Project No. G113575 Date: February 4, 214 REPORT NO. 113575CHI-1 TEST OF ONE LOW VOLTAGE LED TAPE LIGHT - ONE FOOT MODEL NO. DI-V-AV3-9** RENDERED

More information

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. 3195475 Revision Date: January 11, 2010 REPORT NO. 3195475CRT-001 TEST OF ONE LED HANDRAIL FIXTURE MODEL NO. HANDRAIL DRIVER MODEL NO. SOANAR

More information

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727 REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727 Project No. G101454628 Date: December 12, 2013 INTERTEK REPORT NO. 101464628CRT-001 DIALIGHT REPORT NO. L13025 TEST OF ONE LSA ATEX LINEAR MODEL

More information

IESNA LM79: 2008 Photometric Test Report

IESNA LM79: 2008 Photometric Test Report IESNA LM79: 2008 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-2008 Report Prepared For Alex Truong Product Manager MaxLite Description of Sample: 50W LED POST TOP

More information

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727 REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727 Project No. 101520233 Date: March 6, 2014 INTERTEK REPORT NO. 101520233CRT-001 DIALIGHT REPORT NO. L14010 TEST OF ONE HIGHBAY MODEL NO. HEGMC4PN-SNG

More information

Test Report. Report Number: L15159 Date: Jan 6, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Test Report. Report Number: L15159 Date: Jan 6, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727 Test Report Report Number: L15159 Date: Jan 6, 215 Issued by: 151 Route 34 South, Farmingdale, NJ 7727 Test of one DuroSite 45 36 Unit manufacturer: Dialight Corporation Unit model number: STW5C2N Issued

More information

Product testing and evaluation to IES LM-79-08

Product testing and evaluation to IES LM-79-08 Product testing and evaluation to IES LM-79-08 PRODUCT DESCRIPTION 2 x 2 recessed LED lensed troffer REQUESTED BY REQUEST NUMBER Brent Harris F11053 EQUIPMENT The Measuring and Test Equipment used for

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101900210 Date: November 13, 2014 REPORT NO. 101900210LAX-004 TEST OF ONE POLYGON LINEAR LED 8' PARKING HANGING FIXTURE MODEL NO. LSP9605HU55DV50PKG

More information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 . REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: January 25, 2017 REPORT NO. 102748333CHI-019 TEST OF ONE LED AREA LIGHT MODEL NO. HPAL-NW200-BP9 LED MODEL NO. OSRAM

More information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 . REPORT 4 E. Algonquin Rd., Arlington Heights, IL 000 Project No. G31722 Date: February 1, 20 REPORT NO. 31722CHI-032 TEST OF ONE 300W HIGH BAY LUMINAIRE MODEL NO. HBUD-0K300W LED MODEL NO. PHILIPS 3030

More information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 . REPORT 545 E. Algonquin Rd., Arlington Heights, IL 65 Project No. G12748333 Date: March 16, 217 REPORT NO. 12748333CHI-27 TEST OF ONE LED FLOOD LIGHT FIXTURE MODEL NO. FLC4-NW2 LED MODEL NO. PHILIPS

More information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 . REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102748333 Date: March 16, 2017 REPORT NO. 102748333CHI-029 TEST OF ONE KNUCKLE MOUNT LED FLOOD LIGHT MODEL NO. FLKM-NW70-80 LED MODEL

More information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. Project No. G102283582 Date: September 17, 2015 REPORT NO. 102283582CRT-001 TEST OF ONE

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test 12306-3-R01 This test report supersedes test report number 12306-3. Performance Summary Luminous flux Luminaire Power 4164 lm 47.5 W PREPARED FOR : Raffino Inc. Page 1 of 8 USA: LightLab

More information

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L Report of Test 12307-2-R03 This test report supersedes test report number 12307-2-R02. Performance Summary Luminous flux Luminaire Power 5009 lm 58.5 W PREPARED FOR : Raffino Inc. Page 1 of 8 USA: LightLab

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU LM-79 Test Report Relevant Standards IES LM-79-28 IES TM-3-215 CIE 13.3-1995 Product SKU MATTONE 2 LED Step Light Fixture DI-MAT2-HL-* *No Faceplate Test Conditions Test Temperature: 24.3 C Luminaire Sample:

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX60

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX60 LM-79 Test Report Relevant Standards IES LM-79-28 IES TM-3-215 CIE 13.3-1995 Product SKU INFINILINE X 12V LED Light DI-12V-INFX6 Test Conditions Test Temperature: 26.5 C Luminaire Sample Length: 12 in.

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX27

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX27 LM-79 Test Report Relevant Standards IES LM-79-8 IES TM-3-15 CIE 13.3-1995 Product SKU INFINILINE X 1V LED Light DI-1V-INFX27 Test Conditions Test Temperature: 26.5 C Luminaire Sample Length: 12 in. Power

More information

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK Project No. G Date: October 29, 2010 REPORT NO CRT-001 TEST OF ONE LED DESK LAMP

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK Project No. G Date: October 29, 2010 REPORT NO CRT-001 TEST OF ONE LED DESK LAMP REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045 Project No. G100225920 Date: October 29, 2010 REPORT NO. 100225920CRT-001 TEST OF ONE LED DESK LAMP FIXTURE MODEL NO. ADAPTER MODEL NO. JY15-240-050-UD

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101918458 Date: October 9, 2015 REPORT NO. 101918458LA-094 TEST OF ONE ACL PAR 200 RENDERED TO ELATION LIGHTING 6122 S. EASTERN AVE COMMERCE

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 258 COMMERCENTRE DRIVE, LAKE FOREST, CA 9263 Project No. G11918458 Date: February 2, 215 REPORT NO. 11918458LAX-1 TEST OF ONE LED MOVING HEAD MODEL NO. PLATINUM PROFILE PRO RENDERED TO ELATION LIGHTING

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE Basics 100 LED Tape Light - DI-24V-BLBSC1-63-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE Basics 100 LED Tape Light - DI-24V-BLBSC1-63-*** LM-79 Test Report Relevant Standards IES LM-79-28 IES TM-3-215 CIE 13.3-1995 Product SKU BLAZE Basics 1 LED Tape Light - DI-24V-BLBSC1-63-*** Test Conditions Test Temperature: 26.5 C Luminaire Sample Length:

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 258 COMMERCENTRE DRIVE, LAKE FOREST, CA 9263 Project No. G11918458 Date: February 2, 215 REPORT NO. 11918458LAX-7 TEST OF ONE LED PAR ZOOM MODEL NO. ARENA Q7 ZOOM 1 RENDERED TO ELATION LIGHTING

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU LM-79 Test Report Relevant Standards IES LM-79-8 IES TM-3-15 CIE 13.3-1995 Product SKU VALENT X High-Output LED Tape Light - DI-24V-VLX8-42-*** Test Conditions Test Temperature: 26.5 C Luminaire Sample

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU LM-79 Test Report Relevant Standards IES LM-79-28 IES TM-3-215 CIE 13.3-1995 Product SKU VALENT X High-Output LED Tape Light - DI-24V-VLX8-5-*** Test Conditions Test Temperature: 26.5 C Luminaire Sample

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24V-BLBSC1-30-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24V-BLBSC1-30-W*** LM-79 Test Report Relevant Standards IES LM-79-8 IES TM-3-15 CIE 13.3-1995 Product SKU BLAZE BASICS LED Tape Light - DI-24V-BLBSC1-3-W*** Test Conditions Test Temperature: 26.5 C Luminaire Sample Length:

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU LM-79 Test Report Relevant Standards IES LM-79-8 IES TM-3-15 CIE 13.3-1995 Product SKU EMERY BEAM Wet Location Linkable LED Batten - DI-EB35-48L-W48-1V Test Conditions Test Temperature: 26.5 C Luminaire

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU LM-79 Test Report Relevant Standards IES LM-79-2008 IES TM-30-2015 CIE 13.3-1995 Product SKU EMERY BEAM Wet Location Linkable LED Batten - DI-EB40-48L-W48-10V Test Conditions Test Temperature: 26.5 C Luminaire

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL35-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL35-90** LM-79 Test Report Relevant Standards IES LM-79-28 IES TM-3-215 CIE 13.3-1995 Product SKU BLAZE 24V LED Tape Light DI-24V-BL35-9** Test Conditions Test Temperature: 24.9 C Luminaire Sample Length: 12. in.

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL28-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL28-90** LM-79 Test Report Relevant Standards IES LM-79-8 IES TM-3-15 CIE 13.3-1995 Product SKU BLAZE 24V LED Tape Light DI-24V-BL28-9** Test Conditions Test Temperature: 24.8 C Luminaire Sample Length: 12. in.

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV50-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV50-90** LM-79 Test Report Relevant Standards IES LM-79-8 IES TM-3-15 CIE 13.3-1995 Product SKU FLUID VIEW 24V LED Tape Light DI-24V-FV5-9** Test Conditions Test Temperature: 25.2 C Luminaire Sample Length: 12.

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV24-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV24-90** LM-79 Test Report Relevant Standards IES LM-79-28 IES TM-3-215 CIE 13.3-1995 Product SKU FLUID VIEW 24V LED Tape Light DI-24V-FV24-9** Test Conditions Test Temperature: 25.1 C Luminaire Sample Length:

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV20-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV20-90** LM-79 Test Report Relevant Standards IES LM-79-8 IES TM-3-15 CIE 13.3-1995 Product SKU FLUID VIEW 24V LED Tape Light DI-24V-FV-9** Test Conditions Test Temperature: 25.1 C Luminaire Sample Length: 12.

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-27-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-27-*** LM-79 Test Report Relevant Standards IES LM-79-28 IES TM-3-215 CIE 13.3-1995 Product SKU Blaze Basics 2 LED Tapelight DI-12V-BLBSC2-27-*** Test Conditions Test Temperature: 26.5 C Luminaire Sample Length:

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-50-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-50-*** LM-79 Test Report Relevant Standards IES LM-79-28 IES TM-3-215 CIE 13.3-1995 Product SKU Blaze Basics 2 LED Tapelight DI-12V-BLBSC2-5-*** Test Conditions Test Temperature: 26.5 C Luminaire Sample Length:

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU DI-24V-ES30-BK 3000K BLACK.

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU DI-24V-ES30-BK 3000K BLACK. LM-79 Test Report Relevant Standards IES LM-79-8 IES TM-3-15 CIE 13.3-1995 Product SKU DI-24V-ES3-BK 3K BLACK Test Conditions Test Temperature: 25 C Luminaire Sample Length: 49.8 in. Power Supply: Agilent

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 17025:2005. REPORT 25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101777651 Date: August 14, 2014 REPORT NO. 101777651LAX-002 TEST OF

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 REPORT 258 COMMERCENTRE DRIVE, LAKE FOREST, CA 9263 Project No. G1167677 Date: June 5, 214 REPORT NO. 1167677LAX-13 TEST OF ONE WHITE FULL ON ZOOM IN MODEL NO. PLATINUM WASH 16RPRO RENDERED TO ELATION

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-12-BLBSC2-50-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-12-BLBSC2-50-W*** LM-79 Test Report Relevant Standards IES LM-79-28 IES TM-3-215 CIE 13.3-1995 Product SKU BLAZE BASICS LED Tape Light - DI-12-BLBSC2-5-W*** Test Conditions Test Temperature: 26.5 C Luminaire Sample Length:

More information

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24-BLBSC2-30-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24-BLBSC2-30-W*** LM-79 Test Report Relevant Standards IES LM-79-28 IES TM-3-215 CIE 13.3-1995 Product SKU BLAZE BASICS LED Tape Light - DI-24-BLBSC2-3-W*** Test Conditions Test Temperature: 26.5 C Luminaire Sample Length:

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 1725:25. REPORT 258 COMMERCENTRE DRIVE, LAKE FOREST, CA 9263 Project No. G1167677 Date: April 29, 214 REPORT NO. 1167677LAX-4 TEST OF ONE OUTDOOR 6

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 1725:25. REPORT 258 COMMERCENTRE DRIVE, LAKE FOREST, CA 9263 Project No. G1167677 Original IssueDate: April 29, 214 Revision Date : May 1, 214 REPORT

More information

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 1725:25. REPORT 258 COMMERCENTRE DRIVE, LAKE FOREST, CA 9263 Project No. G1167677 Original Issue Date:April 28, 214 REPORT NO. 1167677LAX-3 TEST OF

More information

LUNERA SERIES L7 _ GEN 3

LUNERA SERIES L7 _ GEN 3 Continuous Run Linear Direct / Indirect LED Luminairies Description The Lunera SERIES L7-G3 is a third generation family of linear LED luminaires for continuous run applications. The elegant, slim fixtures

More information

LINEAR DOWNLIGHT - PENDANT DIRECT

LINEAR DOWNLIGHT - PENDANT DIRECT Project Type Notes PERFORMANCE PER LINEAR FOOT AT 3500K MICROGROOVE SPOTLESS LENS NOMINAL LUMEN OUTPUT INPUT WATTS EFFICACY DISTRIBUTION UP DOWN 0up/100down at 900 lm/ft 0 880 lm/ft 10 W/ft 87 lm/w MICROGROOVE

More information

IESNA LM-79: Measurement and Test Report for Venture Lighting International Aurora Road, Suite A, Solon, OH 44139,United states

IESNA LM-79: Measurement and Test Report for Venture Lighting International Aurora Road, Suite A, Solon, OH 44139,United states IESNA LM-79: 28 Measurement and Test Report for Venture Lighting International 32 Aurora Road, Suite A, Solon, OH 44139,United states Aug 14, 215 Product Name: LED corn bulb Model No: VL1-OR54-4E39-AE

More information

LXT Series 2x2/2x4 LED/FLUOR

LXT Series 2x2/2x4 LED/FLUOR FEATURES & SPECIFICATIONS INTENDED USE The LXT offers the look and feel of a fluorescent luminaire - subtle soft direct elements, interest and depth across the ceiling plane - with a contemporary look

More information

Evaluating and Specifying LED Lighting

Evaluating and Specifying LED Lighting Evaluating and Specifying LED Lighting Cotillion Rm 2 2:45-3:45 Troy Hornung, LC, IESNA Traditional Lamps LEDs are Systems CRI color temperature LM-79 LM-80 color shift Remote Phospher R9 Color Macadam

More information

WEATHERPROOF LUMINAIRE

WEATHERPROOF LUMINAIRE info@nextgenerationled.be www.nextgenerationled.be Tel + 32 53 71 09 42 WEATHERPROOF LUMINAIRE Properties n Lifespan L80 %: > 50.000 hours n IP class : 68 n Extremely robust : IK10 n Lumen efficiency :

More information

Draft Technical Requirements Version 4.3. October 20, 2017

Draft Technical Requirements Version 4.3. October 20, 2017 Draft Technical Requirements Version 4.3 Field Adjustable Products Color Tunable Products 3-foot, 8-foot, and 2G11 Base Replacement Lamps October 20, 2017 Notes Slides will be posted on www.designlights.org

More information

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED DALI

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED DALI LEDVANCE DOWNLIGHT LED DALI LED downlight luminaires with DALI AREAS OF APPLICATION Direct replacement for luminaires with compact fluorescent lamps General illumination Public areas Stairways Corridors

More information

DATASHEET. Intematix ChromaLit. Remote Phosphor Light Source. Features & Benefits. Applications and Uses. Unprecedented design freedom for solid state

DATASHEET. Intematix ChromaLit. Remote Phosphor Light Source. Features & Benefits. Applications and Uses. Unprecedented design freedom for solid state DATASHEET Intematix ChromaLit Remote Phosphor Light Source Features & Benefits Unprecedented design freedom for solid state lighting products and systems Customizable shape, size and CCT Custom saturated

More information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005 Project No. G102765760 Date: October 17, 2016 REPORT NO. 102765760CHI-001 TEST OF ONE LED GROW LIGHT MODULE MODEL NO. 1950-A-GL RENDERED TO ADURA

More information

DATASHEET. Intematix ChromaLit. Remote Phosphor Light Source. Features & Benefits. Applications and Uses

DATASHEET. Intematix ChromaLit. Remote Phosphor Light Source. Features & Benefits. Applications and Uses DATASHEET Intematix ChromaLit XT Remote Phosphor Light Source Features & Benefits High operating temperature/high lumen output Off-state Neutral Color Meets V0 flammability requirement and UV resistant

More information

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC W 84th St, Shawnee, KS LED120WPT50KMOG-G6

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC W 84th St, Shawnee, KS LED120WPT50KMOG-G6 IESNA LM-79: 28 Measurement and Test Report for EiKO Global, LLC 2322 W 84th St, Shawnee, KS 66227 Product Name: Model No: LED HID REPLACEMENT LED12WPT5KMOG-G6 Test Engineer: David Zhang Report No.: BTR66.181.15.16.32

More information

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED LEDVANCE DOWNLIGHT LED LED downlight luminaires AREAS OF APPLICATION Direct replacement for luminaires with compact fluorescent lamps General illumination Public areas Stairways Corridors Foyers Shops

More information

T5 LED Integrated Lamp

T5 LED Integrated Lamp T5 LED Integrated Lamp T5 INTEGRATED LAMP MODELS MODEL NO. NOMINAL LENGTH INPUT POWER (W) CCT DELIVERED LIGHT OUTPUT (LM) T5N130 T5N135 T5N150 T5N230 T5N235 T5N241 T5N250 T5N330 T5N335 T5N341 T5N350 T5N430

More information