Pendant Light Fittings Series 6050

Size: px
Start display at page:

Download "Pendant Light Fittings Series 6050"

Transcription

1 > Saltwaterresistant enclosure, aluminium alloy, optionally with painting > Maintenancefree operation and long service life with induction lamp or LED > Mounting with ring bolts or tiltable mounting bracket > With connection box for easy installation > IP68 (10 m depth of immersion for 30 min) at size E00 ATEX / IECEx / GOST Zone For use in x x x x WebCode 6050A Lighting /1

2 Selection Table Version Lamps Lamp holder Pendant light fitting, size 1 up to 250 W; Zone 1, 21 Lamp wattage Temperature class at Ta = T O max at Ta = 40 C Order number Weight 40 C 50 C QT W T4 T4 142 C 6050/ W T3 142 C 6050/ LME W T4 123 C 6050/ TCTSE 7 23 W T6 70 C 6050/ HIE 7 70 W T5 T4 90 C 6050/ W T4 105 C 6050/ W T4 125 C 6050/ HSE 7 50 W T5 T4 100 C 6050/ W T5 T4 100 C 6050/ W T4 106 C 6050/ QL Special 55 W T6 66 C 6050/ W T6 66 C 6050/ Order Number Supplement Suspension two insert threads M8 in the cover of the light fitting 6050/ with additional mounting bracket for ceiling and wall mounting 6050/ Cable entries 2 x M25 x 1.5 (standard) 1 x cable entry, 1 x stopping plug 6050/ (in connection box) 2 x M20 x x cable entry, 1 x stopping plug 6050/ x NPT ¾ 2 x threaded holes 6050/ x NPT 1 2 x threaded holes 6050/ Compensation without compensation 6050/ with compensation 6050/ Wire guard without wire guard 6050/ with wire guard 6050/ Switchoff on opening without switch 6050/ with switch 6050/ Notes: QT LME TCTSE HIE HSE QL LED Halogen lamp Blended lamp Compact lamp Metal halide lamp Highpressure sodium lamp Induction lamp (supplied with light fitting) LED (supplied with light fitting) The pendant light fitting is unpainted; painting is possible (on request) The pendant light fittings are supplied without lamps (see Accessories); Exception: lamps QL and LED External reflector (see Accessories) /2 Lighting

3 Selection Table Version Lamps Lamp holder Pendant light fitting, size 3 up to 500 W; Zone 1, 21 QT LME Lamp wattage 205 W 250 W Temperature class at Ta = 40 C 50 C T3 T4 T4 T O max at Ta = 40 C 142 C 120 C Order number Weight 6050/ LME 500 W T3 T3 154 C 6050/ HIE 250 W T4 108 C 6050/ W T4 127 C 6050/ HSE 150 W T5 T5 95 C 6050/ W T4 108 C 6050/ W T4 120 C 6050/ QL Special 165 W T6 75 C 6050/ Order Number Supplement Suspension two insert threads M10 in the cover of the light fitting 6050/ with additional mounting bracket for ceiling and wall mounting 6050/ Cable entries (in connection box) 2 x M25 x 1.5 (standard) 1 x cable entry, 1 x stopping plug 6050/ x M20 x x cable entry, 1 x stopping plug 6050/ x NPT ¾ 2 x threaded holes 6050/ x NPT 1 2 x threaded holes 6050/ Compensation without compensation 6050/ with compensation 6050/ Wire guard without wire guard 6050/ with wire guard 6050/ Switchoff on opening without switch 6050/ with switch 6050/ Notes: QT LME HIE HSE QL Halogen lamp Blended lamps Metal halide lamps Highpressure sodium lamps Induction lamps (supplied with light fitting) The pendant light fitting is unpainted; painting is possible (on request) The pendant light fittings are supplied without lamps (see Accessories); exception: lamps QL External reflector (see Accessories) Lighting /3

4 Selection Table Version Lamps Lamp holder Lamp wattage Temperature class at Ta = 40 C 55 C T O max at Ta = 40 C Ordering code Pendant light fitting LED Special 65 W T4 T4 100 C 6050/ Series 6050LED, size 1 LED* Special 65 W T4 T4 100 C 6050/ W; Zone 1, 21 LED Special 65 W T6 80 C 6050/ Order Number Supplement Suspension two insert threads M8 in the cover of the light fitting 6050/ with additional mounting bracket for ceiling and wall mounting 6050/ Cable entries (in connection box) 2 x M25 x 1.5 (standard) 1 x cable entry, 1 x stopping plug 6050/ x M20 x x cable entry, 1 x stopping plug 6050/ x NPT ¾ 2 x threaded holes 6050/ x NPT 1 2 x threaded holes 6050/ Wire guard with wire guard 6050/ without wire guard 6050/ Internal reflector with internal reflector 6050/ without internal reflector 6050/ Switchoff on opening with switch 6050/ Notes: LED LED LED* LED temperature controlled The pendant light fitting is unpainted; painting is possible (on request) The pendant light fittings are supplied with LED Weight /4 Lighting

5 Explosion Protection Version 6050/1 6050/3 6050/5LED Global (IECEx) Gas and dust IECEx PTB X IECEx PTB Ex de IIC T3, T4, T5, T6 Ex d e op IIC T4, T6 Ex td A21 IP6X T80... T154 C Ex tb IIIC T... C See selection table See selection table Europe (ATEX) Gas and dust PTB 03 ATEX 1096 (Zone PTB 11 ATEX 1045 E II 2 G EEx de IIC T. (Zone E II 2 G Ex d e opis IIC T Gb E II 2 D IP66 T O max. (Zone 2 E II 2 D Ex tb IIIC T C Db See selection table See selection table Certificates IECEx, ATEX, India (PESO), Kazakhstan IECEx, ATEX (GOSTK) Other certificates Ship approval (GL) Marking (CE) C 0158 C 0158 Technical Data Electrical data Rated operational voltage U e 220, 230, 240, 250 V AC (± 6 %), 50 Hz für 6050/1 und 6050/3, andere auf Anfrage 100 V V AC 50 / 60 Hz für 6050/5 LED Angaben auf dem Typschild beachten! Rated current Lamp type *) Lamp holder Power Light I N Current QT LME W 205 W 500 W 160 W 250 W 500 W 2870 lm 4200 lm lm 3200 lm 5400 lm lm 0.65 A 0.95 A 2.27 A 0.73 A 1.20 A 2.32 A TCTSE 7 23 W 1500 lm 0.10 A HIE W 100 W 150 W 250 W 400 W 5100 lm 7700 lm lm lm lm 0.43 A 0.55 A 0.80 A 1.35 A 2.10 A HSE QL Special Special Special 50 W 70 W 110 W 150 W 250 W 400 W 55 W 85 W 165 W 4000 lm 5600 lm 8000 lm lm lm lm 3500 lm 6000 lm lm 0.30 A 0.38 A 0.63 A 0.80 A 1.35 A 1.97 A 0.26 A 0.40 A 0.73 A LED Special 65 W 5300 lm V V *) QT LME TCTSE HIE Halogen lamp Blended lamp Compact lamp Metal halide lamp HSE QL LED with gas discharge lamps, rated current is compensated (λ > 0,9) Highpressure sodium lamp Induction lamp LED Power factor Disconnection of the light Ambient conditions Ambient temperature cos p ) 0.9 (compensated) 2pole; when opening safety glass cover (option) for 6050/1: for 6050/3: for 6050/5: C / + 50 C C for lights with QL lamps C for TCTSE C / + 50 C C at T4 / T 100 C C at T6 / T80 C Service life LED h T a = 40 C h T a = 50 C teperature controlled (LEDs dimmed at T a > 40 C) h T a = 50 C Lighting /5

6 Technical Data Mechanical data Degree of protection IP66; IP68 (10 m immersion depth 30 min) only for size 1 Protection class I(internal + external PE / PA connection) Material Enclosure material Light metal Protective glass Temperatureresistant pressed glass Cover seal NBR Internal reflector Highpolished aluminium External reflector Highest grade aluminium Wire guard Steel wire (stainless steel) Enclosure lock M4, Torx screw head Assembly / Installation Operating position pendant mounting or slewing angle ± 40 Cable gland Standard 2 x M25 x 1.5; 1 x cable gland d mm, 1 x stopping plug Special 2 x M 20 x 1.5; 1 x cable gland d mm, 1 x stopping plug 2 x NPT 3 / 4 threaded holes 2 x NPT 1 threaded holes Connection option L1 + N + PE for 4 mm 2 singlewire / finely stranded Mounting via 2 x M8 / 2 x M10 insert threads in the cover of the light fitting alternative: via additional mounting bracket (stainless steel), tiltable in 10 steps Wire guard and external can easily be mounted later using a mounting screw M6 reflector Accessories and Spare Parts Designation Illustration Description Art. no. Weight kg Power Lamp holder Voltage Light current Halogen lamp QT 205 W V 4200 Im E W 230 V Im 150 W V 2870 lm Blended lamp LME 160 W V 3200 lm E W 230 V 5400 lm 500 W 230 V lm Compact lamp TC TSE 23 W V 1500 Im E00 Highpressure sodium lamp HSE 04963E00 70 W V 5600 Im 110 W * V 8000 Im * to be operated without starter 150 W 230 V Im W 230 V Im W 230 V Im /6 Lighting

7 Accessories and Spare Parts Designation Illustration Description Art. no. Weight Highpressure sodium lamp HSE (TwinArc) 04963E00 50 W V 4000 Im 70 W V 6500 Im kg W 230 V lm 250 W 230 V lm Metal halide lamp HIE 400 W 230 V lm 70 W V 5100 Im E W V 7700 Im W V Im 250 W 230 V lm Mercury lamp HME 400 W 230 V Im 125 W V 6200 lm E W 230 V Im Induction lamp QL 400 W 230 V Im 55 W Sonder 230 V 3500 lm E00 85 W Sonder 230 V 6000 lm 165 W Sonder 230 V lm Protective glass Protective glass with fixingring 10291E00 for 6050/11 for 6050/ External reflector 10288E00 Complete with mounting parts Material: highpolished aluminium for 6050/11, spot beam for 6050/31, broad beam Wire guard for 6050/11, broad beam Complete with mounting parts Material: steel wire, stainless steel E00 for 6050/11 for 6050/31 for 6050/ Mounting bracket Complete; stainless steel (for additional mounting) for 6050/11 and 6050/51 for 6050/ E00 Lighting /7

8 Accessories and Spare Parts Designation Illustration Description Art. no. Weight kg Singlepoint mounting fixture 04697E00 The stainless steel mounting fixture is fastened to the enclosure of the pendant light fitting series 6050 by means of two stainless steel screws M8. for 6050/11 und 6050/ for 6050/ Ceiling mount For direct installation of the light on the ceiling 13942E00 for 6050/11 and 6050/51 1 pair for 6050/31 1 pair Ring bolt M8, direct mounting in insert nuts, 1 pair M10, direct mounting in insert nuts, 1 pair E00 Cable gland of moulded material, series /5M piece E /5M pieces /5M piece /5M pieces Stopping plug of moulded material, series /3M20 1 piece E /3M pieces /3M25 1 pieces /3M pieces Rotary actuator 14162E00 To tighten the protective glass pieces /8 Lighting

9 Dimensional Drawings (All Dimensions in mm) Subject to Alterations 10283E E E E00 without wire guard with wire guard with external reflector with mounting bracket 6050/ /31 L b d with wire guard L b d1 6050/ / Pendant light fittings /1 and 6050/3 6050/ /31 L b d with mounting bracket L b d1 l a c e 6050/ / Lighting /9

10 b b ø d1 ø d1 L L without wireguard 14990E00 L b d1 6050/ ,8 228 with wire guard 14991E00 L b d1 6050/5 283,8 177,8 228 Pendant light fitting /5 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /10 Lighting

Pendant Light Fitting IEC Series 6470/2

Pendant Light Fitting IEC Series 6470/2 > Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection

More information

EXLUX ECOLUX C-LUX 6480 Series

EXLUX ECOLUX C-LUX 6480 Series EXLUX ECOLUX C-LUX 6480 Series 6000 6008 6400 6408 6600 6608 6500 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent

More information

Explosion Proof Audible Signal db(a) Series YA60

Explosion Proof Audible Signal db(a) Series YA60 > Omnidirectional high output sounder 110 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > 32 selectable

More information

EXLUX ECOLUX 6480 Series

EXLUX ECOLUX 6480 Series EXLUX ECOLUX 6480 Series L I G H T I N G 6000 6008 6400 6408 6600 6608 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent

More information

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem

More information

Circuit-Breakers for Motor Protection Series 8523/8

Circuit-Breakers for Motor Protection Series 8523/8 > Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting

More information

Explosion Proof Audible Signal db(a) Series YA60

Explosion Proof Audible Signal db(a) Series YA60 > Omnidirectional high output sounder 110 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > 32 selectable

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets SolConeX Series 7570, 7571 CES Series 7575, 7579, 7581 10342E00 The plugs and sockets in the CES system comply with IEC/EN 60 309-1/ -2 (CEE). The small 16 A

More information

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof

Lighting: Fluorescent Lighting FD Series: Cylindrical Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Flameproof ighting: Fluorescent ighting FD Series: Cylindrical Fluorescent ighting Fixtures, Standard and Emergency Battery Back-Up Flameproof 2 x 58 W Compliance Data: ATEX IECEx: ATEX IECEx CE Ex d IIB Ex d IIC

More information

USER MANUAL FOR EXPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE PLFM -.

USER MANUAL FOR EXPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE PLFM -. d.o.o. tel. 049 900, fax 049 46 450 email: tepex@tepex.hr www.tepex.hr USER MANUAL FOR EPLOSION PROTECTED PENDANT LIGHTING FITTING, TYPE. Doc. No: TEPEx.RS.058 Ver : 0 Date: 11.014. SADRŽAJ 1. Manufacturer

More information

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder EXEL - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22 Reinforced polyester resin body G13 bi-pin lamp holder Internal emergency batteries

More information

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122 www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations

SAFJ HI-LUMEN LED S A H I L U M. LED Area Lighting for Hazardous Locations LED Class I, Division 2, Groups A, B, C, & D Class II, Divisions 1 & 2, Groups E, F & G Class III UL 1598A Marine Outside Type UL 1598 Wet Locations UL 844 Hazardous Locations UL 8750 LED Safety Tested

More information

I Ex-protected connectors exlink I

I Ex-protected connectors exlink I Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity

More information

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat

More information

EXPlora. Introduction

EXPlora. Introduction Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant

More information

LIGHTING SOLUTIONS. The bright side of the ship

LIGHTING SOLUTIONS. The bright side of the ship LIGHTING SOLUTIONS The bright side of the ship Philosophy Three things you should know about us 1Established by experienced specialists in 1995, Lightpartner has developed into the leading provider of

More information

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications . Ex-Escape sign luminaires Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications The robust escape sign luminaire The Ex-Lite series of explosion-protected escape sign luminaire

More information

PROPORTIONAL VALVES Sentronic plus

PROPORTIONAL VALVES Sentronic plus 04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital

More information

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/10 Type 605055, Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat and double thermostat with capillary or rigid thermowell

More information

Operating instructions

Operating instructions 108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.

More information

EX-PROTECTED PORTABLE POWER SUPPLY UNITS

EX-PROTECTED PORTABLE POWER SUPPLY UNITS EX-PROTECTED PORTABLE POWER SUPPLY UNTS 125 A for Zone 1 Special requirements apply for power distributions for the use and operation of portable equipment in hazardous areas in Zones 1, 2, 21 and 22.

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire HART, PA Built in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43 Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.

More information

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor With analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation

More information

TFRH Hygienic RTD temperature sensor. CombiTemp TM

TFRH Hygienic RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy

More information

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic. DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar

More information

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001

More information

Motor Protection Circuit Breaker Series 8146/5-V27

Motor Protection Circuit Breaker Series 8146/5-V27 > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent adjustable, phase failure sensitive > Electromagnetic quick release 02966E00 > Robust enclosure

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO. DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full

More information

Model JDF Field Indicator

Model JDF Field Indicator Data Sheet DS/JDF-EN Rev. F Model JDF Field Indicator Engineered solutions for all applications Measurement made easy Digital LCD provides reliable and clear indications Flexible configuration facilities

More information

XML LED X M L L E D. Explosionproof Linear LED Lighting

XML LED X M L L E D. Explosionproof Linear LED Lighting LED Class I, Division 1, Groups C & D Class I, Division 2, Groups C & D Class II, Division 1, Groups E, F & G Class III Simultaneous Presence UL 844 Hazardous Locations IEC Ex d Zone 1 Equivalent UL 924

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-12360 This is to certify that the Cable Gland with type designation(s) ADE & RE; AD; FF; MM; SP; ET; LN. Manufactured by COOPER CAPRI SAS

More information

Filters for Power Lines (Low Leakage Current)

Filters for Power Lines (Low Leakage Current) Filters for Power Lines (Low Leakage Current) 40 to 100 A, 100 db from 150 khz Series/Type: Date: January 2004 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures

More information

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request

More information

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent Areamaster LED Flood/High Bay Luminaires NEC/CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 2 AEx na IIC, Ex na IIC Type 3R, 4, 4X /67 NEC: Marine Outside Type (Salt Water) Wet Locations Applications

More information

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS 3-6VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination

More information

Optical Signal Devices. Free-standing Beacons

Optical Signal Devices. Free-standing Beacons Free-standing Beacons Overview Free-standing Permanent Beacons Flashing Beacons 200/203 201/204 (LED) 209 209 (LED) 210/213 211/214 (LED) 219 219 (LED) 202 Flashing 205 Flashing 209 Flashing Beacon 212

More information

Horn loudspeaker, Ex proof, short/long flare

Horn loudspeaker, Ex proof, short/long flare Horn loudspeaker, Ex proof, short/long flare LH3 UC25XS, LH3 UC25XL en Installation note Horn loudspeaker, Ex-proof, short/long flare Installation en 3 1 Installation 1 2 Figure 1.1 Figure 1.2 4X Figure

More information

Champ-Pak Wall Pack Luminares

Champ-Pak Wall Pack Luminares Restricted Breathing Cl. I, Div. 2 & Zone 2 ( S826) ( S826TB) Cl. III & Simultaneous Presence Marine & Wet Locations The first low-profile wall pack designed specifically for hazardous areas. The Eaton

More information

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H-SR EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

82540/ /2-way diaphragm valves

82540/ /2-way diaphragm valves > > ort size: DN 8... 50, 1/4... 2 (ISO G/NT) > > Valve operates without differential pressure > > High flow rate > > For robust industry solutions > > Damped operation > > Suitable for vacuum > > Solenoid

More information

www.mete-enerji.com.tr INDUSTIAL IEC PLUGS AND SOCKETS INDUSTIAL IEC PLUGS AND SOCKETS Position of the Earthing Contact acc. to IEC 60309-2 225/400-265/460 V~ 60 Hz (1) 3 P+N+ 3 P+ 2 P+ 120/208-144/250V~

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Sentronic PLUS Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications

More information

Panel-mounting thermostats, type series EM

Panel-mounting thermostats, type series EM Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting

More information

User manual Version Ex Remote station XGA 15" family type 17-71KB-45../... Ex Remote station SXGA 18" family type 17-71KB-55../...

User manual Version Ex Remote station XGA 15 family type 17-71KB-45../... Ex Remote station SXGA 18 family type 17-71KB-55../... User manual Version 3.00 Ex Remote station XGA 15" family type 17-71KB-45../... Ex Remote station SXGA 18" family type 17-71KB-55../... User manual Remote station XGA 15'' family Remote station SXGA 18''

More information

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex. Guide for installers METTLER TOLEDO MultiRange System solution Point Ex www.mt.com/support System solution Point Ex Contents Contents Page 1 Safety precautions... 4 2 System overview... 5 2.1 Using the

More information

Pressure transmitter For applications in hazardous areas Model IS-3

Pressure transmitter For applications in hazardous areas Model IS-3 Pressure Pressure transmitter For applications in hazardous areas Model IS-3 WIKA data sheet PE 81.58 for further approvals see page 10 Applications Chemical, petrochemical industry Oil, natural gas Machine

More information

Applications. Standard Materials

Applications. Standard Materials Mercmaster III Low Profile Luminaires : Enclosed and Gasketed Area HID Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical processing

More information

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2 IECEx International Conference 2017 Shanghai, China Electrical Installations Design, Selection, Erection and Inspection Part 2 of 2 10. Cable entry systems and blanking elements 10.2 Selection of cable

More information

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

with additional normally-open signalling contact l With integrated AS interface Safety at Work. Safety Hinge Switch SHS3 In addition to the plug connection version, an SHS with fixed cable connection at the rear is also available Right and left hinged systems possible for optimum cable routing Mounting

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Parts List _2.1. Flygt /.890

Parts List _2.1. Flygt /.890 Parts List 886754_2. Flygt 3069 3069.70/.890 Table of Contents Table of Contents Introduction... 2. Specially approved products... 2 2 Product Description...3 2. The data plate...3 2.2 Approvals...4 2.3

More information

Single Point Flow Monitor SW118 SW119

Single Point Flow Monitor SW118 SW119 SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either

More information

Mechanical flow switch for On/Off control

Mechanical flow switch for On/Off control Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...

More information

DMP 331i / DMP 333i LMP 331 i

DMP 331i / DMP 333i LMP 331 i DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma

More information

NOXLITE LED SPOT. Product family datasheet. Outdoor LED wall luminaires. Areas of application _ Outdoor _ Garages _ Patios, balconies

NOXLITE LED SPOT. Product family datasheet. Outdoor LED wall luminaires. Areas of application _ Outdoor _ Garages _ Patios, balconies NOXLITE LED SPOT Outdoor LED wall luminaires Areas of application _ Outdoor _ Garages _ Patios, balconies Product benefits _ Functional design _ High light output thanks to high-power LED _ Quick and simple

More information

Revision 1.0 Parts List Salvador 1~, 3~

Revision 1.0 Parts List Salvador 1~, 3~ Revision.0 www.grindex.com Parts List 809.8 Salvador ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 The data plate...3 Parts... 4 Exploded

More information

Revision 1.0 Parts List Minor

Revision 1.0 Parts List Minor Revision.0 www.grindex.com Parts List 803.8 Minor Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 The data plate...3 Parts... 4 Exploded view...

More information

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218 9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION OCTALUMINA 120: PARTS LIST AND TECHNICAL INFORMATION HIGH POWER LEDS INNER CORNER LABELED FRAME MOUNTED POWER SUPPLY UNIT EASY PLUG-IN CONNECTION BRACING TECHNIQUE CABLE OUTLET AT THE BOTTOM SYSTEM PACKAGING

More information

Revision 3.0 Parts List Salvador 1~, 3~

Revision 3.0 Parts List Salvador 1~, 3~ Revision 3.0 www.grindex.com Parts List 809.8 Salvador ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data

More information

Parts List _2.1. Flygt /.190

Parts List _2.1. Flygt /.190 Parts List 886747_2. Flygt 3069 3069.60/.90 Table of Contents Table of Contents Introduction... 2. Specially approved products... 2 2 Product Description...3 2. The data plate...3 2.2 Approvals...4 2.3

More information

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Limit switches and pulse output Batch control The MAG 6000 I/6000 I Ex is a microprocessorbased transmitter with a builtin alphanumeric display in several languages. The transmitters evaluate

More information

Coils for solenoid valves

Coils for solenoid valves MAKING MODERN LIVING POSSIBLE Technical leaflet Coils for solenoid valves www.danfoss.com B and A coils Encapsulated coils with long operating life, even under extreme conditions Standard coils for a.c.

More information

TFR5 Room or outdoor temperature sensor. CombiTemp TM

TFR5 Room or outdoor temperature sensor. CombiTemp TM Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical

More information

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump Series description Wilo-Drain STS 65 Thermal winding monitoring Max. fluid temperature: 3-40 C Cable length: 10 m Free ball passage: 65 mm Max. immersion depth: 10 m Equipment/function Thermal motor monitoring

More information

Pilot Valves and Nema 4 Enclosures. Innovative Environmental Solutions

Pilot Valves and Nema 4 Enclosures. Innovative Environmental Solutions Pilot Valves and Nema 4 Enclosures Innovative Environmental Solutions Technical Specification Q Series Solenoid Solenoid used in the remote or integral actuation of dust collector diaphragm or pilot valves.

More information

Liner Quattro AC XB RGBW

Liner Quattro AC XB RGBW Date: Quantity: Company: Project: Liner Quattro AC XB RGBW The Liner Quattro AC XB RGBW is an AC line powered, high brightness luminaire. The luminaire is controllable via DMX512 with auto-addressing for

More information

Revision 2.0 Parts List Minor

Revision 2.0 Parts List Minor Revision.0 www.grindex.com Parts List 803.8 Minor Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data plate...3 Exploded

More information

3 Cleaning. 4 Technical data

3 Cleaning. 4 Technical data EXC+ EXC- Sig- SIG+ SEN- SEN+ 2.4 Attaching cable to the analog board Attaching cable of the weighing cell to the system solution Connect the cable to the appropriate terminal strip of the Ex1 system solution

More information

WLB SERIES HID Lighting for Hose Down Applications

WLB SERIES HID Lighting for Hose Down Applications WLB SERIES W LB HID Lighting for Hose Down Applications Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 1598 Wet Locations NEMA 4X NSF Certified Food Equipment CUL Heavy Hose

More information

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD ATEX II 3 G approval Gases and vapors IIC group, zone 2 Dusts IIIC group, zone 22 When used in Ex areas, the special conditions of the approval must be observed Safety clips to prevent inadvertent detachment

More information

Revision 2.0 Parts List Minette 1~, 3~

Revision 2.0 Parts List Minette 1~, 3~ Revision.0 www.grindex.com Parts List 80.7 Minette ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data plate...3

More information

Safety dialogue solutions

Safety dialogue solutions Characteristics 5 Environment Conformity to standards Products XY2 CH, XY2 CE: EN/IEC 60947-5-1, EN/ISO 13850:2006, UL 508 and CSA C 22-2 n 14 (with suffi x H7) XY2 CB: EN/IEC 60947-5-1, EN/ISO 13850:2006,

More information

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Electronic Pressure Regulator Sentronic PLUS Sentronic PLUS Electronic Pressure Regulator General Electrical Characteristics Nominal Diameter DN (mm) Voltage

More information

Revision 3.0 Parts List Minex 1~ Minex Lite, Minex 3~

Revision 3.0 Parts List Minex 1~ Minex Lite, Minex 3~ Revision 3.0 www.grindex.com Parts List 80.60 Minex ~ 80.7 Minex Lite, Minex 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included...

More information

V 180 Series Photoelectric Switches

V 180 Series Photoelectric Switches D A T A S H E E T V 180 Series Photoelectric Switches VS 180 / VE 180 1 m x VL 180 m 1 m*) *) with polarizing filter v VT 180 110 mm 00 mm n Photoelectric switches of cylindrical design in threaded metal

More information

Figure 1: Device components

Figure 1: Device components Order No. : 2860 10 Order No. : 2830 10 Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe

More information

Linear flow control with actuator IFC

Linear flow control with actuator IFC Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20

More information

Grounding-type plugs and sockets K Product information

Grounding-type plugs and sockets K Product information Product information Plugs and sockets for harsh conditions. SCHUO by MENNEES with the hammer symbol. Acc. to VDE 0105 part 115. Made of high-grade AMAPLAST. Acc. to VDE 0620 for harsh conditions. Application

More information

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS RCA3 SOLENOID S PENTAIR CLEAN AIR SYSTEMS GOYEN RCA3D REMOTE PILOT Remote solenoid pilot valve to control the actuation of dust collector diaphragm valves. RCA3D with flying lead connection INSTALLATION

More information

Revision 1.0 Parts List Mini

Revision 1.0 Parts List Mini Revision.0 www.grindex.com Parts List 822.2 Mini Table of Contents Table of Contents Introduction... 2 Specially approved products...2 Product Description...3 Products included... 3 The data plate...3

More information

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination

Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division 1 factory-sealed LED luminaire for general illumination Engineering Hazard Gard EVLL Series Explosionproof LED Luminaires Class I, Division factory-sealed LED luminaire for general illumination High-performance, high-brightness Hazard Gard EVLL LED Luminaire

More information

E-CORE LED DOWNLIGHT 3000 DATA SHEET 1 / 7. Application:

E-CORE LED DOWNLIGHT 3000 DATA SHEET 1 / 7. Application: DATA SHEET 1 / 7 E-CORE LED DOWNLIGHT 3000 Event centers, conference rooms, cinemas large spaces with sophisticated lighting design set the stage for this powerful downlight. Its compact dimensions and

More information

POWER MOLE SERIES DA GAO RGBT RADIX

POWER MOLE SERIES DA GAO RGBT RADIX Techical Information Radix is a versatile solution for applications in space restricted surroundings. Radix is a compact and functional fixture that combines design with advance LED technology. Table of

More information

Veilux User Manual SVEX-Q18 Intelligence Camera Set

Veilux User Manual SVEX-Q18 Intelligence Camera Set Ex Mark: II 2 GD Ex d IIC T6 Gb, Ta : -15 C to +60 C YHQ18 Explosionproof Camera Manual Ex t IIIC T80 C Db Certificate: Nemko 11ATEX1022 Veilux User Manual SVEX-Q18 Intelligence Camera Set Please carefully

More information

M A R I N E B R I G H T S O L U T I O N S

M A R I N E B R I G H T S O L U T I O N S M A R I N E B R I G H T S O L U T I O N S L I G H T I N G F I X T U R E S Sea Bright has become a well-known and sought brand for the design and manufacture of lighting fixtures. The company is oriented

More information

S020 fluorescent tube luminary

S020 fluorescent tube luminary S020 fluorescent tube luminary DESCRIPTION: Fluorescent lamps S020 are suitable above all for uniform lighting of bigger areas. Lamps from the range S020 are manufactured from extruded aluminium profile

More information