DIAS power supply and DIC 221 fibre optic cable coupling module

Size: px
Start display at page:

Download "DIAS power supply and DIC 221 fibre optic cable coupling module"

Transcription

1 POWER SUPPLY AND FIBRE OPTIC COUPLING MODULE DIC 221 DIAS power supply and DIC 221 fibre optic cable coupling module for the power supply of DIAS function modules, 2 x fibre optic cable connections (DIAS bus) for versatile link The DIC 221 DIAS coupling module is used for supplying power to the connected DIAS function modules. It possesses a fibre optic cable input and a fibre optic cable output for communication with decentralised module groups. At the input the DIC 211 communicates with a DPS 211, DPS 221, DOC 211, DOC 221 or with a DIC 221; a DIC 211 or DIC 221 can be connected to the output for control of the DIAS function modules. Technical data Electrical requirements Supply voltage Supply voltage current consumption V DC The current drawn depends on the connected load (maximum 1 A) Output voltage (DIAS bus supply) minimum V maximum V Total current to the connected DIAS modules Status display maximum 1.5 A + 24 V OK: LED green DC OK: LED green RX: LED green TX: LED yellow Page 1

2 DIC 221 POWER SUPPLY AND FIBRE OPTIC COUPLING MODULE Miscellaneous Article number Hardware version 1.x Standardization UL (E247993) Environmental conditions Storage temperature C Operating temperature C Humidity EMV stability 0 95 %, without condensation in accordance with EN (Industrial area) Resistance to shocks EN m/s² Mechanical dimensions Page 2 b

3 POWER SUPPLY AND FIBRE OPTIC COUPLING MODULE DIC 221 Connections On the front of the fibre optic coupling module the following connections are found: Fiber optic channel 2: output Fiber optic channel 1: input Power supply The connection to the current supply is made via a 2-pole plug wired as follows: Pin Function V supply 2 GND Status displays The status LEDs of the fibre optic cable coupling module indicate the operating status of the module. Tx yellow Tx Illuminates when data to the DIAS bus are being sent. DIAS Rx green Rx Illuminates when data to the DIAS bus are being received. DIAS DC green DC OK Illuminates when the supply voltage to the DIAS bus is available. +24 V green Supply Illuminates when the supply voltage is connected to the DIC Page 3

4 DIC 221 POWER SUPPLY AND FIBRE OPTIC COUPLING MODULE Making up a fibre optic cable (1mm POF) To make a fibre optic cable connection you need a Duplex fibre optic cable with a 1mm diameter optical fibre and two fibre optic cable plugs. 1. A 12 cm length of the insulating sheath must be removed. Caution: Do not damage the covering of the fibre optic cable. 2. Separate the fibre optic cable up to about 7 cm from the end, and trim about 1 cm of insulation off each lead. Make sure that you do not damage the fibre optic cable! For stripping the Duplex fibre optic cable special stripping pliers are available. Fibre optic cable Type Attenuation Plug Cable (duplex) Maximum length 1mm POF 220dB/km HFBR-4516 (duplex) Hitronic lead: HPZ PUR PMMA 1 50 m *Aluminium crimping (suitable for use with a rings for HFBR-4516* dragline) 200µm HCS 8dB/km HFBR-4521 (simplex) BP04703 (case for two simplex plugs) Laser components order no.: Huber + Suhner: 02-H200/VJZ-AD (suitable for use with a dragline) m * The crimping rings delivered by HP are not recommended by Sigmatek. We recommend the aluminium crimping rings, which are obtainable (order no ). If the HFBR-4516 plugs are ordered from us, we deliver the new aluminium crimping rings automatically with them, instead of the original ones. Accessories Type Accessory Tool 1mm POF HFBR-4593 (polishing kit) HFBR-4505 (coupling) HFBR-4597 (crimping pliers) HTX-LWL (crimping pliers)* Weidmüller order no.: µm HCS AP04707 (coupling) Laser Components order no.: HFBR-4584 (installation kit) Page

5 POWER SUPPLY AND FIBRE OPTIC COUPLING MODULE DIC 221 A coupling can be used for extending a fibre optic cable. This is, however, only recommended with HCS! Using a coupling the maximum length with POF is decreased by 20m and with HCS by 100m! When using the original crimping rings, set the crimping pliers to maximum grip (+)! With the aluminium crimping rings the crimping pliers can be left on a weaker position, the durability of the pliers is increased essentially through that Page 5

6 DIC 221 POWER SUPPLY AND FIBRE OPTIC COUPLING MODULE 3. Insert both the stripped leads together into the plug as far as they will go. The leads should now stick out of the front of the plug by a few millimetres. Press down on the plug so that the leads are firmly connected with it. The crimping ring should be closed off with the plastic part: Richtig Wrong Falsch 4. Shorten the leads sticking out of the front of the plug with a small pair of electrician's side cutting pliers so that only about 1 mm remains. With 15µ abrasive paper (manufacturer 3M - colour grey) rub the leads of the fibre optic cable with a figureof-eight motion until they are flush with the casing of the plug. Finally, repeat this procedure with 1µ abrasive paper (manufacturer 3M - colour yellow) (8-10 figures-of-eight). 4 cm Do not kink. Under no circumstances should a bend have a radius less than the bending radius of 4 cm defined by the manufacturer. Also not while the making the cable up! Page

7 POWER SUPPLY AND FIBRE OPTIC COUPLING MODULE DIC 221 When assembling the second plug, make sure the leads of the fibre optic cable are fitted as shown in the previous sketch. Carry out the following test in order to ascertain whether the fibre optic cable has been correctly fitted into the plug. 1. Place the two plugs with the writing on top (see diagram). 2. Cover the marked fibre with the index finger. 3. If light no longer shines through the corresponding fibre in the second plug, the fibre optic cable has been connected in the plug correctly. Cover this fibre This fibre remains dark A fibre optic cable has many advantages, however it must be treated with the level of care required by the manufacturer. To avoid unnecessary strain on the cable you should never pull on the leads when pulling out the fibre optic cable plug! Page 7

8 DIC 221 POWER SUPPLY AND FIBRE OPTIC COUPLING MODULE Page

Analogue output module DAO 081

Analogue output module DAO 081 ANALOGUE OUTPUT MODULE DAO 081 Analogue output module DAO 081 for eight ±10 V DC outputs This analogue output module is used for driving components capable of being analogue driven (e.g. proportional pressure

More information

Data Sheet HFBR-4531Z/4532Z/4533Z/4535Z. Crimpless Connectors for Plastic Optical Fiber and Versatile Link. Features. Description.

Data Sheet HFBR-4531Z/4532Z/4533Z/4535Z. Crimpless Connectors for Plastic Optical Fiber and Versatile Link. Features. Description. HFBR-4531Z/4532Z/4533Z/4535Z Crimpless Connectors for Plastic Optical Fiber and Versatile Link Data Sheet Description The HFBR-453xZ series connectors are an enhanced version of the HFBR-4501Z and HFBR-4503Z

More information

K-LWLH1 2.0 m AA. K-LWLH m AA. K-LWLH m AA

K-LWLH1 2.0 m AA. K-LWLH m AA. K-LWLH m AA Glass Fiber Cable The fiber optic cables are used to connect the FM211, FM212, FS211, FS211/N and FS212 and FS212/N FASTBUS modules, enabling the connection of remote substations over large distances with

More information

SECTION 4 TABLE OF CONTENTS

SECTION 4 TABLE OF CONTENTS Contents Introduction LC, SC and ST Series...4-2 Markets and Applications...4-2 International Standard Documents Compliance...4-2 LC Series Features and Benefits...4-3 LC Standard... 4-4 to 4-5 LC for

More information

HP SMA BFOC. Brief instruction. Version. 4en.

HP SMA BFOC. Brief instruction. Version. 4en. HP SMA BFOC Version 4en www.helmholz.com Application and function description The OPTopus PROFIBUS Optical Link is a normal PRO- FIBUS repeater despite its small dimensions. It permits the conversion of

More information

Data Sheet GU-LCT-RY-V1-10 GU-LCT-RY-V1-11

Data Sheet GU-LCT-RY-V1-10 GU-LCT-RY-V1-11 Data Sheet GU-LCT-RY-V1-10 Part No.: AA-10276-001 Optical Input / Output: Glass Fibre GU-LCT-RY-V1-11 Part No.: AA-10276-002 Optical Input / Output: Plastic (POF) Picture shows AA-10276-001 (Glass Fibre)

More information

Linear encoders without bearings incremental System for linear motion feedback

Linear encoders without bearings incremental System for linear motion feedback Features Robust magnetic sensing method Output signals A 90 B with index signal Output circuits: HTL/push-pull and TTL/RS422 Resolution up to 5 µm (4-times evaluation) Non-contact, wear-free sensing system

More information

Connecting cables for valves, Sub-D Type codes

Connecting cables for valves, Sub-D Type codes Type codes NEBV C S1 G 44 K Function NEBV Connecting cables for valves Product design Standard C Easy to clean design Connection technology, left, field device side S1 S7 Sub-D socket Sub-D HD socket Cable

More information

SPECIFICATION. Optical Fiber Cable

SPECIFICATION. Optical Fiber Cable SPECIFICATION Optical Fiber Cable (GYFS) Prepared by Zhang xin Approved by Yin peng xiang 1 1 Product description GYFS is gel-free, single-jacket, single-armored cable for direct burial and duct GYFS is

More information

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements NO: PH-165 PRODUCT: E3S-X3, E3X-NL, E3X-NM DATE: August 2012 TYPE: Discontinuation Update Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements Affected

More information

Connecting cables for valves, round plug connectors Product range overview

Connecting cables for valves, round plug connectors Product range overview Connecting cables for valves, round plug connectors Product range overview Version Type code Connection technology (Electrical connection 2) Electrical connection 1: socket M8x1 4-pin NEBV-M8W4L Plug M8x1,

More information

Local Control Network

Local Control Network Installation guide ocal Control etwork C-G/K C-G: coupling module for glass fibre cables with a range up to km. C-K: coupling module for plastic cables with a range up to 00m. The modules C-G and C-K are

More information

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE Revision No.:01 Date: 07.10.06 SPECIFICATION OF 96F SM LOOSE TUBE, DRY CORE MINI CABLE PART NO.:D-96/SM/MTY(F)-MFN-O6.3 Checked By: Pavan Maheshwari Process Associate Design & Development Team Approved

More information

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance

More information

HI-DEX PRODUCT SET DATASHEET

HI-DEX PRODUCT SET DATASHEET APPLICATION HI-DEX is an ultra high-performance, pre-terminated and modular optical fibre cabling system based on MT ferrule connector technology. This product set is designed for installationn in the

More information

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE Revision No.:00 Date: 08.03.2010 SPECIFICATION OF 192F SM LOOSE TUBE, DRY CORE MINI CABLE PART NO.:D-192/SM/MTY(F)-MFN-O9.1 Checked By: Pavan Maheshwari Process Associate Design & Development Team Approved

More information

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S INSTALLATION MANUAL FT-FOTR-1VDE-ST-S 1-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission & Ethernet Transmission v1.0 4/5/11 1 PACKAGE CONTENTS This package

More information

Revision No. 4 Page No. Page 1 of 7

Revision No. 4 Page No. Page 1 of 7 Page No. Page 1 of 7 Single Mode Optical Fibre Cables With Loose Fibres in Stranded Tubes And Corrugated Steel tape Armouring For Duct Applications LITE KABEL SDN. BHD. reserves the right to make changes

More information

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL Installation and programming Manual v2.2 1 MARSS Solar Defender SYSTEM This guidebook provides the essential instructions to install and configure the

More information

The World Of Professional Fiber Optics. safe flexible reliable

The World Of Professional Fiber Optics. safe flexible reliable The World Of Professional Fiber Optics safe flexible reliable CONTENTS Contents General Info.... 3 2-Channel System.... 6 4-Channel System.... 10 SMPTE System.... 15 Patchcords.... 19 Accessories.... 21

More information

Cables for robot applications

Cables for robot applications Cables for robot applications 67 Primary cables Robot primary cable Cable design Internal conductor Special conductor Strand class VI (super-fine wire) Highly flexible Core insulation TPM or PUR Core identification

More information

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures 004-273-AEN, Issue 2 Table of Contents 1. General.... 1 2. Precautions.... 1 2.1 Cable Handling Precautions...

More information

High intensity led illuminator ILED42A FEATURES: DESCRIPTION: ELECTRICAL CHARACTERISTICS:

High intensity led illuminator ILED42A FEATURES: DESCRIPTION: ELECTRICAL CHARACTERISTICS: High intensity led illuminator May 2010 Rev 0.3 ILED42A FEATURES: High luminous flux Low cost Fully protected Wide input voltage range Available with different led colours and lenses DESCRIPTION: The IDP

More information

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH 1 1 9.41 115 0 Pretium EDGE 143 RFP LC Uniboot to RFP LC Uniboot Patch Pretium EDGE Solutions jumpers are integrated reverse -polarity uniboot duplex assemblies that meet the high -density space requirements

More information

FLEXIBLE SERIES DA LR WW LENTUS

FLEXIBLE SERIES DA LR WW LENTUS Technical Information is an ideal solution which can be used easily for limited areas or thin spaces because of its minimalist design of 1cm, flexible body structure and sticky band feature found behind..

More information

Power Injector 1520 Series

Power Injector 1520 Series Power Injector 1520 Series Technical Specifications Input voltage 100 to 240 VAC Output voltage 56.0 VDC Voltage range tolerance 54 VDC to 57 VDC Maximum current 1.43 A No load current 15 ma 56VDC@0.71A

More information

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

MBUS 10 RS232 TO MBUS LEVEL CONVERTER Media and protocol converters MBUS 10 RS232 TO MBUS LEVEL CONVERTER RS232 to MBus level conversion Maximum 10 MBus slaves Baud Rate: 300 to 19200 bps RS232 MBus opto isolation Over-current and short-circuit

More information

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products MT-RJ Product Expansion Now 0 Variants of the MT-RJ Products In response to several customers, the MT-RJ product line has been expanded with an additional six color/key versions. In addition to the original

More information

Photoelectrics Through-beam Type PA18C.T..., DC

Photoelectrics Through-beam Type PA18C.T..., DC Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:

More information

Photoelectric Sensors E3F2

Photoelectric Sensors E3F2 Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel

More information

Water blocking tape. Locator ridge HPA-0486

Water blocking tape. Locator ridge HPA-0486 Table of Contents STANDARD RECOMMENDED PROCEDURE 004-138 ISSUE 1 MARCH 2012 PAGE 1 OF 12 Sheath Removal and Mid-Span Access of Dielectric ALTOS Cable with FastAccess Technology p/n 004-138, Issue 1 1.

More information

Stretch DVI TM. User s Manual DVFC-100. Manual Contents

Stretch DVI TM. User s Manual DVFC-100. Manual Contents Manual Contents Manual Contents 1-0 Welcome! Product Description 1-1 System Requirements for Setup 1-2 Installation 1-3 Troubleshooting, Maintenance, Technical Support 1-4 Product Specifications 1-5 Warranty

More information

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum. As of May 8, 2012 BRU-SF10 1. Single mode fiber cable supported The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum. 2. Status display on the front panel The following

More information

Selection of a cable depends on functions such as The material Singlemode or multimode Step or graded index Wave length of the transmitter

Selection of a cable depends on functions such as The material Singlemode or multimode Step or graded index Wave length of the transmitter Fibre Optic Communications The greatest advantage of fibre cable is that it is completely insensitive to electrical and magnetic disturbances. It is therefore ideal for harsh industrial environments. It

More information

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body Beta TX Datasheet Beta-TX The Beta-TX is a complete self contained laser diode system which can operate in both CW and modulation modes. The Beta- TX features high speed modulation with a bandwidth of

More information

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

Connecting cables NEBS, for sensors

Connecting cables NEBS, for sensors Connecting cables NEBS, for sensors Connecting cables NEBS, for sensors Product range overview Function Version Type code Connection technology (Electrical connection 2) Connecting cable Cable characteristic

More information

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2 3 Crimplok Connectors Quick, easy installation and superior performance To successfully design, install or operate today s fiber optic networks, you need components that offer speed and reliability from

More information

Original BMW Accessory. Installation Instructions.

Original BMW Accessory. Installation Instructions. Original BMW Accessory. Installation Instructions. ipod Interface Retrofit BMW 5 Series (E 60, E 6) BMW 6 Series (E 63, E 64) These installation instructions are only valid for cars without SA 67 (CD changer)

More information

HARTING Ethernet cabling cables and connectors, 4 wire

HARTING Ethernet cabling cables and connectors, 4 wire Industrial Cat. 5e Standard cable, 4-wire Type A for permanent installation or to build-up PROFINET system cables PVC X 8 wire X Cat. 5e X Cat. 6 Cat. 6 A Cat. 7 Cable structure Core structure Wire insulation

More information

Industriefunkuhren. Technical Manual. Model 7248/7248RC. Fibre Optic Converter Board ENGLISH

Industriefunkuhren. Technical Manual. Model 7248/7248RC. Fibre Optic Converter Board ENGLISH Industriefunkuhren Technical Manual Fibre Optic Converter Board Model 7248/7248RC ENGLISH Version: 01.00-04.05.2007 2 / 16 7248/7248RC Fiber Optic Converter Board - V01.00 INPORTANT NOTES Downloading Technical

More information

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D) 2-3, Marunouchi 2-chome, Chiyoda-ku, Tokyo 100-8322, Japan No. FB-KL4001C for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D) Aug 2014 1 1. General This specification describes

More information

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2 Product Catalogue Fiber Optic Assemblies & Adapters Table of Contents 1. General Description... 2 2. Connectors... 3 2.1 SC/UPC... 3 2.2 SC/APC... 3 2.3 FC/UPC... 3 2.4 FC/APC... 3 2.5 ST/UPC... 3 2.6

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

LONWORKS Fibre Optic Converter

LONWORKS Fibre Optic Converter LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring

More information

Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath

Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.6 N LE 3 Function NEBV Connecting cables for valves Connection technology on left, field device side A1 Plug socket type A, EN 175301-803

More information

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3 Version GYFTY-V1.0 Optical Fibre Cable Technical Specification Duct Cable GYFTY-24,48,72,144,216B1.3 Yangtze Optical Fibre and Cable Joint Stock Limited Company All rights reserved 1. Scope This Specification

More information

SERCOS TSX CSY 84 Module V

SERCOS TSX CSY 84 Module V SERCOS TSX CSY 84 Module V At a Glance Aim of this Part What's in this part? This part presents the SERCOS TSX CSY 84 module, its operating features and its installation. This Part contains the following

More information

HygroClip Introduction

HygroClip Introduction What is the HygroClip? HygroClip ntroduction he HygroClip is a high quality probe for the measurement of humidity and temperature. t is used in a wide range of applications including handheld instruments,

More information

Installation. Step 1 Carefully unpack the package contents.

Installation. Step 1 Carefully unpack the package contents. Installation Important: Please follow the installation procedure below. Improper operation may result if the start-up sequence is not correctly followed. Step 1 Carefully unpack the package contents. Step

More information

-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.

-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0. Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.6 N LE 3 NEBV Connecting cables for valves Connection technology on left, field device side B2 Socket type B to industry standard,

More information

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer Spec No.: ZTT 45012 Revision: 2 Date: Oct 3, 2014 TECHNICAL SPECIFICATION Optical Fiber Cable (Reference: NBR 14566) Designer Senior Technical Manager Approver Chief Technical Engineer Jiangsu Zhongtian

More information

Optical DisplayPort Cable DPM

Optical DisplayPort Cable DPM USER S manual Optical DisplayPort Cable DPM Table of Contents 1. Introduction... 2 2. Features.......2 3. Model name.... 2 4. Panel Descriptions.... 3 5. Package contents......3 6. Installation.....4 7.

More information

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH 1 1 9.41 115 0 Pretium EDGE 143 RFP LC Uniboot to RFP LC Uniboot Patch Pretium EDGE Solutions jumpers are integrated reverse -polarity uniboot duplex assemblies that meet the high -density space requirements

More information

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION 683 SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION 683.01.01 GENERAL A. The Contractor shall furnish the designated quantity of Video Optical Transceiver (VOTR) pairs

More information

HighBand 25. TrueNet Category 6 Solutions

HighBand 25. TrueNet Category 6 Solutions HighBand 25 TrueNet Category 6 Solutions The highest performing cross-connect system in the world. A unique high-density solution with superior cable management. ADC KRONE s HighBand 25 cross connect solution

More information

ETSI ES V1.1.1 ( )

ETSI ES V1.1.1 ( ) ES 202 319 V1.1.1 (2004-06) Standard Transmission and Multiplexing (TM); Passive optical components and cables; Optical fibre cables to be used for patchcord applications for single-mode optical fibre

More information

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK Model MX3257HD Description The rack-mountable MX3257HD fiber optic video multiplexer is ideal for transmitting 1 channel of video, 2 channels

More information

HDMI Extender via 4 Single-mode fibers 4 x LC Connector Extends HDMI + RS232 full-duplex up to 1500 meters

HDMI Extender via 4 Single-mode fibers 4 x LC Connector Extends HDMI + RS232 full-duplex up to 1500 meters Description AMRT-FD-05K-4LC extender enables PC HDMI and RS232 link to far end display monitor through fibers, and the maximum communication distance is up to 1500 meters. AMRT-FD-05K-4LC is pure hardware

More information

OxLinx TM LHM-Pxxx. Classification : Technical Specification. Ⅰ. Preview. Ⅱ. Contents. Spec. No. AD K Date

OxLinx TM LHM-Pxxx. Classification : Technical Specification. Ⅰ. Preview. Ⅱ. Contents. Spec. No. AD K Date Classification : OxLinx TM LHM-Pxxx Spec. No. AD150320-K01-001 Date 2015.06.19 Version AOC Dev. Part Written Team JW Kim Ⅰ. Preview Group HDMI Active Optical Cable Connector type # 4K 30Hz, 3D,

More information

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12 Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12 Our I-IFLRF20 series is a wideband RF over fiber link that provides optical transport of RF signals in radars, satcom, EW/ECM and other antenna remoting

More information

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L Application SWA Cable power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for

More information

Assembly Instructions

Assembly Instructions Assembly Instructions REP Series Environmentally - Sealed Rectangular Plastic Connectors Hypertac S.A. January 2014 Assembly Instructions REP Series January 2014 1 Table of Contents I. Introduction A.

More information

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA Hinges with built-in safety multiple switch SUPER ECHNO POLYMER IP RoHS PA +0-0 MAERIAL Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black or grey colour RAL 00 (C). Rotation pin: glass-fibre

More information

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment. Absolute 60-mm-dia. Rotary Encoder A High Accuracy and Durability for Automatic Equipment Stronger shaft and greater durability (120 N in the radial direction and 50 N in the thrust direction) than previous

More information

Safety Light Curtains GuardShield

Safety Light Curtains GuardShield Description The Allen-Bradley Guardmaster safety light curtain is an economical, fully featured, Type 4 safety light curtain in a uniquely styled housing. safety light curtains are general purpose presence

More information

Single Point Flow Monitor SW118 SW119

Single Point Flow Monitor SW118 SW119 SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either

More information

Fibre Optic Modem ODW-611

Fibre Optic Modem ODW-611 Fibre Optic Modem ODW-611 PROFIBUS DP to fibre optic link, point-to-point applications The ODW-611 is a fibre optic modem designed for point-to-point fibre optic connections between PROFI- BUS DP networks.

More information

POWER LINE BAR SERIES DA PL6 WW NORA

POWER LINE BAR SERIES DA PL6 WW NORA Technical Information Nora is a compact LED luminaire illuminating particularly small or tight spaces in either single colour or RGB. 24V dimmable system with 6 High Power LEDs per 300mm length for homogeneous

More information

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH 1 1 9.41 115 0 Pretium EDGE 143 RFP LC Uniboot to RFP LC Uniboot Patch Pretium EDGE Solutions jumpers are integrated reverse -polarity uniboot duplex assemblies that meet the high -density space requirements

More information

Part Number (used with PRO-CRIMPER Tool Frame ) for 50 Ohm BNC Dual Crimp MIL Type Connectors

Part Number (used with PRO-CRIMPER Tool Frame ) for 50 Ohm BNC Dual Crimp MIL Type Connectors Application Tooling Hand Tools CERTI-CRIMP Hand Tools are our top-of-the-line crimping tools featuring the original ratcheted crimp control. All tools are designed to exacting specifications, and manufactured

More information

SC Type Fiber Optic Connectors

SC Type Fiber Optic Connectors SC Type Fiber Optic Connectors HSC Series Features 1. JIS, IEC standards compliant and fully intermateable with NTT's SC products. JIS C 573 (F4 type fiber optic connectors) IEC 61754-4 2. Plugs with strain

More information

OPTICAL FIBRE CABLE NETWORK 2004/1

OPTICAL FIBRE CABLE NETWORK 2004/1 OPTICAL FIBRE CABLE NETWORK 2004/1 HELKAMA OPTICAL FIBRE CABLES Cabled optical fibre characteristics OS1 singlemode fibre SM ITU-T G.652 Mode field diameter 1310nm 9.3+/-0.5µm Mode field eccentricity 1.0

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

SPECIFICATION. Spec No : VSS-1402-CS603B

SPECIFICATION. Spec No : VSS-1402-CS603B SPECIFICATION Spec No : VSS-1402-CS603B 1. INTRODUCTION 1.1. General This specification covers the design requirements and characteristics required of fiber optic splice closures to be used on fiber optic

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

Single mode 9/125µm, duplex

Single mode 9/125µm, duplex Fiber Converter Module RS-232 MICROSENS General For the connection of devices, control units and machine controls with standard serial interfaces MICROSENS is offering special fiber converters for the

More information

PREMIUM 5e F/UTP PRODUCTS

PREMIUM 5e F/UTP PRODUCTS Siemon s end-to-end cabling system is guaranteed to provide transmission performance margins in excess of industry standards for category 5e parameters, while featuring excellent EMI resistance. has been

More information

Crimp & Cleave Termination Instructions for SEL ST Connectors

Crimp & Cleave Termination Instructions for SEL ST Connectors Your Optical Fiber Solutions Partner Crimp & Cleave Termination Instructions for SEL ST Connectors For Use With: ST Termination Kit (SEL, Part Number BT05402-01) 200 µm HCS Fiber-Optic Cable ST Crimp &

More information

3 SLiC Aerial Closure with Rubber End Seal

3 SLiC Aerial Closure with Rubber End Seal 3 Aerial Closure with Rubber End Seal Instructions 1.0 General 1.1 This instruction bulletin describes the assembly of the 3M Aerial Closure with external bonding hanger brackets. These closures are suitable

More information

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature

More information

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach NEW DRS: Incremental encoders, number of lines and zero pulse width freely programmable DRS: s with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach by pressing

More information

EBU Technical Recommendation R Connectors for camera cables with fibre optical transmission

EBU Technical Recommendation R Connectors for camera cables with fibre optical transmission Connectors for camera cables with fibre optical transmission EBU UER EBU Committee First Issued Revised Re-issued PMC 1999 Keywords: Cameras, digital processing, fibre optical transmission The EBU has

More information

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM Content 1. General 5 2. The products of NC-1000 system 6 3. Mounting of the frame 8 4. Earthing of the frame 8 NC-1000 FIBRE OPTIC

More information

COLOUR CHANGING USB LAMP KIT

COLOUR CHANGING USB LAMP KIT TEACHING RESOURCES SCHEMES OF WORK DEVELOPING A SPECIFICATION COMPONENT FACTSHEETS HOW TO SOLDER GUIDE SEE AMAZING LIGHTING EFFECTS WITH THIS COLOUR CHANGING USB LAMP KIT Version 2.1 Index of Sheets TEACHING

More information

TENDER SUMMARY. Tender Title:

TENDER SUMMARY. Tender Title: TENDER SUMMARY Tender Title: Tender Ref: Closing Date: OPEN TENDER FOR THE SUPPLY OF FIBER OPTIC CABLE 384 CORE LOOSE TUBE ( FOC 384C ) FOR TELEKOM MALAYSIA BERHAD ( TM ) LPM/2018/T/02/FOC 384C 23 February

More information

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras INSTALLATION MANUAL FT-FOTR-8VD-ST-S 8-Channel Digital Duplex Baseband Transmitter and Receiver With Reverse Transmission for PTZ Cameras v1.0 4/5/11 1 PACKAGE CONTENTS This package contains: One each

More information

PROFIBUS Optical networks with OLM

PROFIBUS Optical networks with OLM Overview Used for the optical Industrial Ethernet and PROFIBUS networks Rugged design for industrial applications indoors and outdoors Halogen-free design for installation inside buildings Trailing cable

More information

Follow The Leader In Shielded Technology

Follow The Leader In Shielded Technology 1970s Vampire Tap 1990s Shielded Modular Jack 190s 4 Position Data Connector Follow The Leader In Shielded Technology The new AMP-TWIST Jack is our latest shielded product evolution. It can be terminated

More information

DATA SHEET. Two (2) fibers Detachable DisplayPort Extender, DPFX-100-TR

DATA SHEET. Two (2) fibers Detachable DisplayPort Extender, DPFX-100-TR DATA SHEET Two (2) fibers Detachable DisplayPort Extender, DPFX-100-TR Contents Description Features Applications Technical Specifications Operating Conditions Drawing of Module Drawing of Cable Connection

More information

3M 8900 Single-mode SC Crimplok Connector

3M 8900 Single-mode SC Crimplok Connector 3M 8900 Single-mode SC Crimplok Connector Technical Report June 1999 80-6110-1441-8 1 1.0 Product Description & Requirements The 3M SC Single-mode Crimplok Connector is designed to provide the customer

More information

ASP-FIBRS1 User Manual

ASP-FIBRS1 User Manual ASP-FIBRS1 HDMI Single Fiber Extender with Serial and IR User Manual Manual Number: 100823 Safety and Notice The ASP-FIBRS1 HDMI Extender over 1 fiber with serial and IR have been tested for conformance

More information

Cylindrical Photoelectric Sensor CY-100 SERIES

Cylindrical Photoelectric Sensor CY-100 SERIES Cylindrical Photoelectric Sensor CY-00 SERIES Listing (2 m cable length type only) Features Wide product range Shape: Standard type Side view type Connector: 2 m cable length type M2 plug-in connector

More information

Stretch HDMI TM. User s Manual (M1-2000)

Stretch HDMI TM. User s Manual (M1-2000) Stretch HDMI TM User s Manual (M1-2000) Manual Contents Manual Contents 1-0 Welcome!, Product Description 1-1 System Requirements for Setup 1-2 Installation 1-3 Troubleshooting, Maintenance, Technical

More information

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48 NS-200AF Series Industrial 0/00 Base-TX to 00 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T NS-200AFT-T 00Base-FX e F -30 ~ +75 +2 ~ +8 LAN x x Fiber Optic Features C C Temperature Automatic

More information

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL DVBus 8350-16 and 8350-4 Multiplexer and demultiplexer assemblies for 16-4 video channels, with bidirectional audio and data USER MANUAL 1. Description. Indicators and system connections DVBus 8350 systems

More information

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

2179-CD Series Fiber Optic Splice Closure. Installation Instructions 2179-CD Series Fiber Optic Splice Closure Installation Instructions 1.0 Product Introduction The new 3M TM 2179-CD Series Fiber Optic Splice Closure can be used in buried, underground, aerial, and pedestal

More information

ENC - LKE51 - L I B

ENC - LKE51 - L I B ENC-LKE51 Linear Magnetic Encoder FEATURES DESCRIPTION LKE51 ORDERING INFORMATION Resolutions: 5, 10, 25, and 50μm Linear Travel Speed: Up to 16m/s Standard Sensor for Linear and Rotary Axis Gap Clearance

More information

Product model and standard

Product model and standard Preface Thank you for purchasing the Ikan Blitz 400 HD Wireless Video System. This system features uncompressed high definition video with zero delay. Before using the product, please read this user s

More information

Original BMW Accessories. Installation Instructions.

Original BMW Accessories. Installation Instructions. Original MW ccessories. Installation Instructions. ipod Interface Retrofit MW 5 Series (E 60, E 6) MW 6 Series (E 63, E 64) These installation instructions are only valid for cars with S 67 (CD changer)

More information