OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices

Size: px
Start display at page:

Download "OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices"

Transcription

1 OASIS CSI (Certified Security Integrators) Direct Attach Warranty for ESS Devices Berk-Tek recommends installing a well-designed structured cabling channel per the TIA standards. This includes up to 100 meters of twisted pair horizontal cabling terminated on both ends with a modular jack and corresponding Category cables. In the TR, the cable is connected to the patch panel and on the device end, the camera is attached to the solids horizontal cable through an RJ-45 terminated patch cord to the workstation outlet. In some real world IP applications that extend outside the voice and data scope, such as security cameras and access point devices, there are circumstances that do not allow a jack-to-outlet scenario on the device end. The TIA-862 standard for BAS applications recognizes these circumstances and allows the elimination of a workstation outlet and patch cord at the device end, when deemed unsafe and unfeasible. This includes, but not limited to, applications such as cameras, access controls, industrial sensors, lighting and wireless access points. Berk-Tek s OASIS 15-year warranty through the CSI program will cover a single ended direct attach when using any RJ-45 plugs that meet the most recent TIA standards, installed to best practices through the OASIS CSI training and provide proper test results. (Plug installation instructions are available from Berk-Tek.. See testing procedures further in this document). However, the plugs on the chart have been tested and approved by the Nexans DCCC and are recommended with Berk-Tek cable: Manufacturer Category 5e Category 6 Berk-Tek UTP Plenum & Riser* 1 HyperPlus-5e LANmark-350 LANmark-6 LANmark-1000 LANmark-2000 Termination Tool Bel Stewart SS SS Sentinel L L AllenTel - AT8X8RCSC-24 AT 568, AT 680 Metz Connect i i Tooless** * See Bek-Tek catalog or Website for cable part numbers: ** Does not require a connector crimper or additional termination tools To order plugs, contact your local distributor.

2 Guidelines for best installation practices This guide is intended to provide basic guidelines for the installation of Berk- Tek copper cabling products. The use of this guide is not a substitute for installation training through the OASIS CSI program. Installation practices outlined in ANSI/TIA -568-C and the BICSI TDMM Manual must be followed. Maximum Cable Lengths Per the channel and permanent link requirements of ANSI/TIA -568-C 90 meters horizontal cabling 10 meters total patch cables Cable Slack It is recommended to provide additional cable slack at both ends to accommodate future cabling system changes Telecommunications closet: 10 feet Telecommunications outlet: 12 inches for twisted pair cables Maximum Cable Pull Force UTP Cables: 25 lbs-f Handling of Cable Boxes Boxes must be stored and handled in an upright position to reduce the chance of twisting and kinking the cable especially if the box is partially used Cable Bend Radius UTP: 4 times the cable diameter or 1 inch Cable Management and Pulling Practices Eliminate cable stress Control tension in suspended cable runs by limiting spans between supports to 5 ft or less Avoid tightly cinched cable bundles Avoid kinking during installation Avoid changing the geometry of the cable 2

3 Follow manufacturers recommendations for loading of cable trays and j-hooks. The use of tie wraps should be avoided. Staples are prohibited When pulling cable apply pulling force evenly to all conductors in the cable. Avoiding kinking the cable when dressing the cable. Avoid exceeding the maximum bend radius for the cable. Connector Termination Follow the manufacturer s guidelines for termination of connectors and patch panels Plug Installation Guidelines If the direct attach method needs to be used, there are some guidelines for attaching plugs. Following these procedures will help to assure that the plug contacts line up and work properly. But, since there are no standards to attaching plugs other than lining up the conductors to match TIA-568-A or B, each plug design varies between manufacturers. Use these as guidelines, but refer to the manufacturers specific instructions and use their recommended tools: If there is a strain relief (boot), slide it on the cable Trim off 1 to 1 ½ of the jacket and untwist the pairs Align the conductors to match the proper color layout for either TIA- 568A or 568B, depending on the other end of the termination in the TR If there is a load bar or management bar, trim the conductors at a slight angle. If no load bar, evenly cut straight across (to make it easier to load in) Line up the conductors on the load bar and trim the excess wire once pushed through. There should be no more than a total of ½ of untwisted wire from the tip of the housing to the cable jacket Make sure that all conductors touch the end of the housing and are visible when looking thru the end of the housing If there is a strain relief, slide up to the rear of the plug housing Using the manufacturers recommended crimp tool, crimp the plug into place. This is a critical step because if done incorrectly the wires can become loose and lose end to end contact. 3

4 Testing Procedures for a Direct Attach A Single Connector Modified Permanent Link is the name that is given to the test procedure for a Category 5E or Category 6 direct attach plug-ended configuration where the 90-meter length of horizontal cable is punched down at the near end patch panel and an RJ-45 plug is attached at the device far end. The test equipment utilizes a test equipment cord on the near end attached to a Permanent Link Adapter and is directly attached to a channel adapter at the far end. A Consolidation Point (CP) may be also be located between the near and far ends. The upcoming BICSI-005 Guide for the Design and Implementation of Electronic Safety and Security (ESS) Structured Cabling will be ratified in 2012 and recognizes the direct attach as a viable connectivity for ESS devices. The following recommended test procedures according to Underwriters Laboratories (UL File E349672, Project 11CA44391) should be followed: Configuration 1 Direct Attach A 90-meter length of horizontal cable terminated (punched down) to a randomly selected port of the near end patch panel and an RJ-45 plug on the work area/device far end. The hand-held tester shall be fitted with the permanent link adapter on the near end and a channel adapter on the work area plug far end. 4

5 Configuration 2 Direct Attach with a Consolidation Point A 90-meter length of horizontal cable terminated (punched down) to a randomly selected port with consolidation point connector (RJ-45) 85 meters from the near end and a RJ-45 plug on the work area/device far end. The hand-held tester shall be fitted with the permanent link adapter on the near end and a channel adapter on the work area plug far end. (Note: UL Testing exhibited results that complied for both passive and active testing. Passive testing included set-ups Configurations 1 and Configuration 2 as stated above and pictured using a Fluke DTX-1800 hand-held tester. Active testing included Configurations 1 and 2 utilizing the Spirent Smartbits SMB 2000 Active Bit Error Rate Tester set-up for 1GBASE- T through-put measurements of the following frame sizes: 64, 128, 256, 512, 1024, 1280, and For specific test results, contact UL, Reference File E349672, Project 11CA44391.) 5

6 Obtaining a CSI OASIS Warranty on a Direct Attach Project Security Integrator must have completed CSI training Integrator logs in to and completes the project registration for an OASIS warranty. Integrator will provide BOM/POS from distributor along with the proper test data. This information will be uploaded with the project. Upon completion of the project registration the project is reviewed and processed within 30 days. OASIS Warranty Certificate is issued via to the OASIS Integrator. For more information, contact: Carol Everett Oliver, RCDD/ESS Specialist Marketing Analyst, Berk-Tek Ph: For information on the OASIS program, contact: Anita Woods, Marketing Programs Coordinator Ph:

STRUCTURED CABLE SYSTEM (SCS)

STRUCTURED CABLE SYSTEM (SCS) PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated

More information

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1. PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated

More information

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents PART 1 - GENERAL 1.1 SUMMARY SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors. 3. Cabling system identification products. 1.2

More information

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION COMMUNICATIONS HORIZONTAL CABLING (NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) PART 1 - GENERAL 1.1 SECTION

More information

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION COMMUNICATIONS HORIZONTAL CABLING SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors including patch panels. 3. Cabling identification

More information

Multi-Media Installation Guide

Multi-Media Installation Guide Multi-Media Installation Guide Coaxial Page 2 Data Plug Page 7 Data Jack Page 10 Telephone Page 13 Splicing Page 15 Cable Types Cable Types Two basic types of cable are used in multimedia installations.

More information

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017 Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM-2017-2 Date: 05/26/2017 Additional specification information for data communication to cameras and between Library

More information

REQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus

REQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus REQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus PART 1: GENERAL REQUIREMENTS A. Contractor Work 1. Provide and install (except as noted in this document), cable,

More information

Lab - Build and Test Network Cables

Lab - Build and Test Network Cables Introduction In this lab, you will build and test straight-through and crossover Unshielded Twisted-Pair (UTP) Ethernet network cables. Note: With a straight-through cable, the color of wire used by pin

More information

HDBT Installation Guide

HDBT Installation Guide KRAMER ELECTRONICS LTD. HDBT Installation Guide MODELS: Kramer HDBT Cable Recommendations for Usage and Termination Guidelines For the latest information on our products and a list of Kramer distributors,

More information

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU

LANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU LANmark PCB patch panel, 1HU INSTALLATION GUIDE LANmark PCB patch panel, 1 HU Document information Document reference Release September 2001 Published by Contact address BRO-009 LANmark PP 1HU 0701 Nexans

More information

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System 10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System Next-Generation Category 6A UTP Cabling System Drivers for 10 GbE Aggregation of Gigabit Links Server Consolidation and

More information

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION PART 1 - GENERAL 1.1 SUMMARY SCOPE SECTION 25170 TESTING, IDENTIFICATION AND ADMINISTRATION 1. This section includes the minimum requirements for the testing, certification administration and identification

More information

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab* Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab* General Scope of Work: Supply and installation of Computer Laboratory setup in MIU Location of Installation:

More information

6000 Series Patch Panel Terminating Instructions

6000 Series Patch Panel Terminating Instructions 6000 Series Patch Panel Terminating Instructions INTRODUCTION The 6000 Series patch panels include a unique feature not found on any other patch panel. This feature allows you to angle each of the four

More information

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School BILOXI PUBLIC SCHOOL DISTRICT Biloxi Junior High School Request for Proposals E-Rate 2014-2015 - Internal Connections Submit Proposals To: Purchasing Department Attn: Traci Barnett 160 St. Peter Street

More information

LITWARRANTY Rev. 5 W a r r a n t y P r o g r a m S t r u c t u r e d C a b l i n g S y s t e m s

LITWARRANTY Rev. 5 W a r r a n t y P r o g r a m S t r u c t u r e d C a b l i n g S y s t e m s LITWARRANTY Rev. 5 W a r r a n t y P r o g r a m S t r u c t u r e d C a b l i n g S y s t e m s STRUCTUREd CAbLINg SYSTEm WARRANTY PRogRAm As transmission speeds continue to increase, HellermannTyton

More information

ADDENDUM NO. 2 This addendum consists of 8 pages. Kenai Peninsula Borough Purchasing & Contracting

ADDENDUM NO. 2 This addendum consists of 8 pages. Kenai Peninsula Borough Purchasing & Contracting KENAI PENINSULA BOROUGH Purchasing and Contracting 144 North Binkley Street Soldotna, Alaska 99669-7520 Toll-free within the Borough: 1-800-478-4441, Ext. 2260 PHONE: (907) 714-2260 FAX: (907) 714-2373

More information

LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU. empty. Clip-on. with Sliding mechanism. Black or white INSTALLATION GUIDE

LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU. empty. Clip-on. with Sliding mechanism. Black or white INSTALLATION GUIDE LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU empty Clip-on with Sliding mechanism Black or white INSTALLATION GUIDE LANsense Modular Patch Panel for 24 Snap-in Connectors Document information

More information

CATEGORY 6 CABLING SOLUTIONS

CATEGORY 6 CABLING SOLUTIONS With over 20 years experience and know-how on communicating products design & developing, Premium Line has built maturity systems both in high tech develop and research center & complete structural quality

More information

The University of Texas at Austin September 30, 2011

The University of Texas at Austin September 30, 2011 SECTION 27 08 20 COPPER TESTING PART 1 - GENERAL 1.1 SUMMARY A. Test measurements shall be taken for all balanced-twisted pair cabling, including horizontal and backbone copper cables and wall-to-rack

More information

Advanced PoE - The Impact of Higher Power PoE++ on Twisted-Pair Structured Cabling

Advanced PoE - The Impact of Higher Power PoE++ on Twisted-Pair Structured Cabling Advanced PoE - The Impact of Higher Power PoE++ on Twisted-Pair Structured Cabling Next Generation PoE Connect significantly more devices due to higher power Affects cabling due to the additional heat

More information

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE Prepared in cooperation and approval from BICSI Building Industry Consulting Services International and

More information

Belden IBDN System 10GX Enabling Technologies

Belden IBDN System 10GX Enabling Technologies Belden IBDN System 10GX Enabling Technologies by Paul Kish Director, Systems and Standards Revision 1 November 2008 Belden Belden IBDN System 10GX Enabling Technologies 1/17 Introduction The IEEE 802.3an

More information

Belden IBDN System 10GX The next level of cabling performance

Belden IBDN System 10GX The next level of cabling performance Belden IBDN System 10GX The next level of cabling performance by Paul Kish Director Belden IBDN Systems and Standards Introduction There is a new standard under development in the IEEE 2.3an task force

More information

A. All communications equipment rooms shall be installed in a neat and workmanlike manner.

A. All communications equipment rooms shall be installed in a neat and workmanlike manner. SECTION 27 11 00 - COMMUNICATIONS EQUIPMENT ROOM FITTINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

FT-45 Ordering Information

FT-45 Ordering Information FT-45 Ordering Information FT-45 Feed Thru Modular Plug Crimp Tool Item No. Description 30-495 FT-45 Feed-Thru Modular Plug Crimp Tool 30-4951 FT-45 Replacement Blade Cat 6 Feed-Thru RJ45 Modular Plugs

More information

PREMIUM 5e F/UTP PRODUCTS

PREMIUM 5e F/UTP PRODUCTS Siemon s end-to-end cabling system is guaranteed to provide transmission performance margins in excess of industry standards for category 5e parameters, while featuring excellent EMI resistance. has been

More information

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment E Cable Certification General Testing Criteria (Applies to all cable certification testing) 1. RCIT reserves the right to be present during any or all cable testing procedures. The Contractor shall obtain authorization from

More information

CHABOT- LAS POSITAS COMMUNITY COLLEGE DISTRICT

CHABOT- LAS POSITAS COMMUNITY COLLEGE DISTRICT CHABOT- LAS POSITAS COMMUNITY COLLEGE DISTRICT Purchasing and Warehouse Services Department October 1, 2007 Addendum No. 1 INVITATION FOR BID No. 08-09 Temporary Faculty Offices, Chabot College All Prospective

More information

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP 0G A is Siemon s advanced, end-to-end augmented category UTP structured cabling system, designed to meet or exceed all 0GBASE-T performance requirements, including alien crosstalk. Siemon s full channel

More information

Lab Building Straight-Through and Crossover UTP Cables

Lab Building Straight-Through and Crossover UTP Cables Lab 4.5.3 Building Straight-Through and Crossover UTP Cables Objective Build and test straight-through and crossover Unshielded Twisted Pair (UTP) Ethernet network cables. Background / Preparation In this

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 05 14.00 10 (April 2006) -------------------------------- Preparing Activity: USACE Superseding UFGS-27 05 14.00 10 (April 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

DATA/TELECOMMUNICATIONS REQUEST FOR PRICING

DATA/TELECOMMUNICATIONS REQUEST FOR PRICING Category 6A 10Gig DATA/TELECOMMUNICATIONS REQUEST FOR PRICING TABLE OF CONTENTS 1. GENERAL 3 1.1. Work Included... 3 1.2. Scope of Work... 3 1.3. Regulatory References... 4 1.4. Quality Assurance... 4

More information

SECTION FIBER OPTIC STATION CABLES

SECTION FIBER OPTIC STATION CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications shall include all labor necessary to perform and complete such construction, all materials and equipment incorporated

More information

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue. Description: OZLINX CAT5e cable has a guaranteed performance; exceeds the Category 5e performance requirements and provides positive PSACR up to 155MHz for bandwidth requirement in the future. Product

More information

Modular Six pack Patch Panel. for 24 Snap-in Connectors. Clip-on and Shutters. with Sliding mechanism INSTALLATION GUIDE

Modular Six pack Patch Panel. for 24 Snap-in Connectors. Clip-on and Shutters. with Sliding mechanism INSTALLATION GUIDE Modular Six pack Patch Panel for 24 Snap-in Connectors 1 HU empty Clip-on and Shutters with Sliding mechanism INSTALLATION GUIDE Modular Six pack Patch Panel 24 Snap-in Connectors with Sliding mechanism

More information

Excel recommends Fluke Networks, this section is written around the use of this range of test equipment.

Excel recommends Fluke Networks, this section is written around the use of this range of test equipment. Testing Excel recommends Fluke Networks, this section is written around the use of this range of test equipment. Twisted Pair Copper This section describes and sets out the requirements for Class D (Cat

More information

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14 Table of contents About Nexans 3 About Berk-Tek 4 Hyper Plus 5e Cat 5e UTP 5 HyperPlus 5e Plenum 6 Hyper Plus 5e Riser 10 HyperPlus 5e Patch 14 HyperPlus 5e OSP 18 22 7/10/07 - http://www.berktek.com Page

More information

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION COMMUNICATIONS HORIZONTAL CABLING SECTION 27 15 00 COMMUNICATIONS HORIZONTAL CABLING PART 1 GENERAL 1.1 RELATED DOCUMENTS AND SECTIONS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

Section Communications Optical Fiber Backbone Cabling

Section Communications Optical Fiber Backbone Cabling Part 1 1.1 Related Documents 1.1.1 Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specifications Sections apply to this Section. 1.2 Related

More information

Copyright Black Box Corporation. All rights reserved.

Copyright Black Box Corporation. All rights reserved. Copyright 2003. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 SOHO 6-Port CAT5e 568B Data Module SEPTEMBER 2003 JPM1101A CUSTOMER SUPPORT

More information

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11 Table of contents About Nexans 3 About Berk-Tek 4 LANmark-1000 Cat 6 UTP 5 LANmark-1000 Category 6 Plenum 6 LANmark-1000 Category 6 Riser 11 LANmark-1000 Category 6 Patch 16 21 7/10/07 - http://www.berktek.com

More information

CABLING STANDARDS FOR

CABLING STANDARDS FOR RFB for Wiring in the Outagamie County Courtrooms Attachment B September 1, 2016 CABLING STANDARDS FOR GENERAL The purpose of this document is to provide guidelines for all structured cable installations

More information

NYULMC AMBULATORY CARE CENTER FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: Issued for GMP March 15, 2017

NYULMC AMBULATORY CARE CENTER FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: Issued for GMP March 15, 2017 SECTION 27 15 00 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Telecommunications Cabling System Technical Specification for the K-12 Educational Environment Enhanced Category 5

Telecommunications Cabling System Technical Specification for the K-12 Educational Environment Enhanced Category 5 Telecommunications Cabling System Technical Specification for the K-12 Educational Environment Enhanced Category 5 1.0 INTRODUCTION Customer to define background and introduction to the project based on

More information

Data Communications Competence Center

Data Communications Competence Center s Data Communications Competence Center DCCC00 June 9, 00 Test Summary Active testing was performed on Berk-Tek s -pair, Category e cables. The testing demonstrates the ability of this cable to reliably

More information

FUTURE PROOF YOUR CONNECTIONS

FUTURE PROOF YOUR CONNECTIONS FUTURE PROOF YOUR CONNECTIONS DataMax Commercial Data Cable The Strongest Link. When you choose Quabbin Wire and Cable you are not only selecting a premier cable, you are also investing in productivity

More information

WIRE AND CABLE FIRE TESTS

WIRE AND CABLE FIRE TESTS TEST CSA C22.2 No 2556-13 Section 9.4 (FV-2/VW-1) (Small Scale Vertical) # OF VALUES REPORTED FOOTAGE REQUIRED 3 3 pieces: 24 each 5 7 days PERFORMANCE TIME CSA-FT1 (Small Scale Vertical) 3 5 pieces: 24

More information

Product Line Reference Guide

Product Line Reference Guide Product Line Reference Guide COPPER CABLING SYSTEMS AFL Copper Products COPPER CABLING SYSTEMS Copper Cabling Systems AFL s copper cabling systems are the best-in-class, providing superior performance

More information

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions Robert Burén Product Manager 10G Solutions Nexans Cabling Solutions 1 10 Gigabit Ethernet.Performance 30 GByte can be transmitted within 24 seconds Example: MRI-scan size is 30GB as average A memory device

More information

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS 10 Gigabit Ethernet is nowadays viable solution for destinations with very high data traffic concentration like data center, server farms, MAN s and backbones. Premium Line Category 6A Cabling Solutions

More information

What is SnoCam? SnoCam Installation Guide. SolarVu

What is SnoCam? SnoCam Installation Guide. SolarVu 4 1 2 3 4 5 6 7 8 D+ Rx- GND V+ GND V+ Power 1 2 3 4 5 6 7 8 9 10 What is? SolarVu Installation Guide SolarVu is an energy portal that enables remote monitoring of renewable energy generation sites over

More information

Copper Cabling Troubleshooting Handbook

Copper Cabling Troubleshooting Handbook NETWORKSUPERVISION Copper Cabling Troubleshooting Handbook NETWORKSUPERVISION Table of Contents Introduction 2 Troubleshooting Basics 3 Link Models 4 The automated DTX Series diagnostics 5 Causes of Cabling

More information

384A Adapter Installation Instructions

384A Adapter Installation Instructions Instruction Sheet 860237684 Issue 9, October 2012 SYSTIMAX Solutions 384A Adapter Installation Instructions General The 384A adapter (Figure 1) is a broadband video adapter that provides connectivity to

More information

How to Implement PoE in Your Harsh Industrial Environment

How to Implement PoE in Your Harsh Industrial Environment Produced by: Engineering 360 Media Solutions July 2018 How to Implement PoE in Your Harsh Industrial Environment Sponsored by: Quabbin Wire & Cable Co., Inc. There is little doubt that the internet of

More information

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE Conduit Installation A conduit cable installation involves placement of one or more optical cables inside a preinstalled

More information

Premise Installation Guide

Premise Installation Guide Premise Installation Guide Table Of Contents Overview of Cabling Standards...1-2 Horizontal Cabling System Structure...3-5 Work Area... 6 Horizontal Distances of Copper Links (Open Office)... 7 Twisted

More information

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS 10 Gigabit Ethernet is nowadays viable solution for destinations with very high data traffic concentration like data center, server farms, MAN s and backbones. Need of 10 Gigabit Service Application as

More information

Data Communications Competence Center

Data Communications Competence Center The Effect of Short Link Resonance on the NEXT and PSNEXT Performance of 7m Channels Data Communications Competence Center DCCC082102R1 July 11, 07 Test Summary This report compares the results of NEXT

More information

CATEGORY 5e CABLING SOLUTIONS

CATEGORY 5e CABLING SOLUTIONS With the high speed data transmission requirement in LAN, 1998 IEEE ratified standard 802.3z defined protocol 1000BASE-T over Category 5e and higher level Ethernet cabling system. After that, with the

More information

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK

POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK POET-1 P.O.E. TEST PORT MEASUREMENT TOOL INSTRUCTION BOOK IB6386-01 9-1-2015 TABLE OF CONTENTS DESCRIPTION 2 HOW TO CABLE THE POET-1 2 HOW TO TAKE A MEASUREMENT 3 EASE OF USE 3 APPLICATIONS 3 CARE AND

More information

HDM-4X2. Installation Manual. HDMI Matrix Switcher. HLE-1 RX HDMI Extender with HDBaseT-Lite. HDMI Out. IR In. Receiver.

HDM-4X2. Installation Manual. HDMI Matrix Switcher. HLE-1 RX HDMI Extender with HDBaseT-Lite. HDMI Out. IR In. Receiver. HDM-4X2 HDMI Matrix Switcher Installation Manual HDBaseT IR Out HLE-1 RX HDMI Extender with HDBaseT-Lite Receiver IR In HDMI Out Power HDMI HDBT Table of Contents Introduction... 3 Safety Information...

More information

DINTEK LAN Cabling Systems

DINTEK LAN Cabling Systems 4 Pair UTP Cable Application: Voice Fast Ethernet(IEEE802.3) VgAnyLAN(IEEE 802.12) Token Ring(IEEE 802.5) TPPMD(ANSI X3T9.5) BaseT Ethernet(IEEE 802.3u) 155/622 Mbps 1.2/ 2.4 Gbps ATM 0BaseT Ethernet 550

More information

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax

More information

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project 1.1.0 GENERAL The purpose of this specification is to establish a requirement for the installation of a voice, video and data cable network. The cable (copper), wire, hardware, equipment racks, jumpers,

More information

3M Telecommunications. Solutions for Networks. 3M MPO solutions. High Density Networks. Technology built for business

3M Telecommunications. Solutions for Networks. 3M MPO solutions. High Density Networks. Technology built for business 3M Telecommunications Solutions for Networks 3M MPO solutions High Density Networks Technology built for business 2 3M Telecommunications Solutions for Networks 3M Telecommunications Solutions for Networks

More information

Follow The Leader In Shielded Technology

Follow The Leader In Shielded Technology 1970s Vampire Tap 1990s Shielded Modular Jack 190s 4 Position Data Connector Follow The Leader In Shielded Technology The new AMP-TWIST Jack is our latest shielded product evolution. It can be terminated

More information

Volition TM RJ45 K5e Jacks

Volition TM RJ45 K5e Jacks Volition TM RJ45 K5e Jacks Part of our 3M Volition Network Solutions, the new K5e range is our ultimate Category 5e hardware component (ISO/IEC 11801, EN 50173 and ANSI/TIA/EIA-568). The K5e jack is a

More information

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk Paul Vanderlaan Product Development Engineer Belden Presented at BICSI January 20, 1999 Introduction New Parameters involving

More information

NCB-C6SGRYR M Category 6 STP Solid Cord. Specification. Doc. Version: /09/30

NCB-C6SGRYR M Category 6 STP Solid Cord. Specification. Doc. Version: /09/30 NCB-C6SGRYR-305 305M Category 6 STP Solid Cord Specification Doc. 2010/09/30 Version History Date Version Description 2010/04/13 1.0 Initial (Dennis Yu) Add Conductor OD Insulation Material/OD/Average

More information

Magic Patch Patch Leads & Accessories

Magic Patch Patch Leads & Accessories Magic Patch Patch Leads & Accessories T: 01376 346600 F: 01376 346620 www.connectixcablingsystems.com Issue 1.1 Magic Patch Cabling Systems TM Magic Patch Connectix Cabling Sytems TM range of patch leads,

More information

RCIT Cable Certification Testing Revised 10/2017

RCIT Cable Certification Testing Revised 10/2017 RCIT Testing Revised 10/2017 General Testing Criteria (Applies to all cable certification testing) 1. RCIT reserves the right to be present during any or all cable testing procedures. The Contractor shall

More information

Information & Communications Technology Network Infrastructure Group. Network Infrastructure Standards June 2008

Information & Communications Technology Network Infrastructure Group. Network Infrastructure Standards June 2008 Information & Communications Technology Group Standards June 2008 Appendix F UTP cabling Version 1.1 Appendix F UTP cabling 1. Introduction This Section details the required standards for Unshielded Twisted

More information

VGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters

VGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters VGA Extender over Cat 6 with Audio Support Model 103004 Extend both video and audio up to 300 meters Utilize a Cat 6 cable instead of a bulky VGA cable Supports a local monitor and local audio Easy installation

More information

TEST REPORT NO.: CRT-081 RENDERED TO: Hubbell Premise Wiring 14 Lord s Hill Road Stonington, CT

TEST REPORT NO.: CRT-081 RENDERED TO: Hubbell Premise Wiring 14 Lord s Hill Road Stonington, CT 3933 US ROUTE 11, CORTLAND, NEW YORK 1345, U.S.A. Phone Number: 1-8-345-3851 Fax Number: 67-758-3648 PROJECT NO.: 322866-311 DATE: February 19, 29 TEST REPORT NO.: 322866CRT-81 RENDERED TO: Hubbell Premise

More information

User Manual. HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D

User Manual. HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D User Manual HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D Model 1180T Transmitter Model 1180R Receiver Model 1180TD Transmitter Model 1180RD Receiver WARNINGS Read these

More information

Liberty Mutual Structured Cabling Specification Bid and Build Structured Cabling Technical Specification for:

Liberty Mutual Structured Cabling Specification Bid and Build Structured Cabling Technical Specification for: Bid and Build Structured Cabling Technical Specification for: Horizontal & Backbone Requirements Page 1 of 30 PUBLICATION RECORD Document Version Publication Date Primary Author Description Revision 1.0

More information

SOLICITATION ADDENDUM NO. 1 ITB THE FOLLOWING CHANGES TO THE ABOVE CITED SOLICITATION ARE ANNOUNCED.

SOLICITATION ADDENDUM NO. 1 ITB THE FOLLOWING CHANGES TO THE ABOVE CITED SOLICITATION ARE ANNOUNCED. Beaverton School District Capital Program Purchasing 16550 SW Merlo Road, Beaverton, OR 97006 Phone: 503-591-4539 SOLICITATION ADDENDUM NO. 1 ITB 15-0012 THE FOLLOWING CHANGES TO THE ABOVE CITED SOLICITATION

More information

5e. Max bandwidth is 400MHz Cat 6 max bandwidth of 500MHz Cat 6E max bandwidth of 550MHz ( E stands for enhanced ) Cat 6A max bandwidth of 625MHz

5e. Max bandwidth is 400MHz Cat 6 max bandwidth of 500MHz Cat 6E max bandwidth of 550MHz ( E stands for enhanced ) Cat 6A max bandwidth of 625MHz Before we talk about Hubbell s range of Copper connectivity products we first need to understand the difference between the various categories of copper products! Quite simply put the category of a copper

More information

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet VGA Extender over Single CAT 6 Cable with Audio Support Model 103004 Extend both video and audio up to 1000 feet Utilize a Cat 6 cable instead of a bulky VGA cable Supports a local monitor and local speakers

More information

FLUID VIEW 12V LED TAPE LIGHT

FLUID VIEW 12V LED TAPE LIGHT DRY LOCATION FLUID VIEW 12V LED TAPE LIGHT Medium brightness Available in 8+ CRI 16.4 ft. maximum run UL Listed & R/C SAM Manual Suitable for closet use 5-Year limited warranty SUITABLE FOR CLOSET USE

More information

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables revision history Issue Date Reason for Change Related literature SRP-004-136 Accessing All-Dielectric DX Armored Fiber Optic Cables Admonishments 1. General This procedure provides instructions for installing

More information

Cat.6 4 Pair UTP Cable

Cat.6 4 Pair UTP Cable 4 Pair UTP Cable Application: Voice Fast Ethernet(IEEE802.3u) VgAnyLAN(IEEE 802.12) Token Ring(IEEE 802.5) TPPMD(ANSI X3T9.5) BaseT Ethernet(IEEE 802.5) 155/622 Mbps 1.2/ 2.4 Gbps ATM 0BaseT Ethernet 550

More information

SECTION 7 -- CROSS-CONNECT SYSTEMS

SECTION 7 -- CROSS-CONNECT SYSTEMS DETAIL ENGINEERING REQUIREMENTS AT&T March, 2016 Section 7, ATT-TP-76400 Revised NA SECTION 7 -- CROSS-CONNECT SYSTEMS CONTENTS PAGE 1. GENERAL... 7-2 1.1. Introduction... 7-2 1.2. Cable Holes... 7-2 1.3.

More information

Compact Module. Category 6 FTP Cabling System

Compact Module. Category 6 FTP Cabling System Compact Module Shielded design for improved EMI performance Suitable for Gigabit Ethernet applications and beyond Ultra-slimline design Colour coded for quick and accurate termination Interchangeable with

More information

QuickNet Copper Cabling in the Data Center

QuickNet Copper Cabling in the Data Center Application Guide QuickNet Copper Cabling in the Data Center QuickNet Copper Cabling Systems With the benefits of quick network deployment, assured performance, quality, and easy redeployment, the Panduit

More information

Clarity Advanced Solutions6A

Clarity Advanced Solutions6A Clarity Advanced Solutions6A Clarity 6A connectivity more effectively supports the internal and alien performance requirements of 10 Gigabit Ethernet. Clarity 6A components use Ortronics innovative technique

More information

Tools & Accessories JackEasy Termination Tool TAS. Tools & Accessories

Tools & Accessories JackEasy Termination Tool TAS. Tools & Accessories JackEasy Termination Tool TAS Anti-Slip Grip Sturdy Metal Body The JackEasy Tool Makes Terminating Faster & Easier! USE WITH ICC'S EZ AND HD MODULES! Features: Sturdy Metal Body - Manufactured with a steel

More information

Copper Solution Contents Cabinets Fiber Optic Solution

Copper Solution Contents Cabinets Fiber Optic Solution Contents Copper Solution Category 6A + Cabling Solutions Cat.6A + 1000MHz S/FTP Installation Cable A1 Cat.6A + S/FTP Patch Cord A2 Cat.6A + 90 Fully Shielded Die-casting Keystone Jack A3 Modular German

More information

Use Case Summary. Faisal Ahmad, Akros Silicon IEEE 802.3bt, September 2014

Use Case Summary. Faisal Ahmad, Akros Silicon IEEE 802.3bt, September 2014 Use Case Summary Faisal Ahmad, Akros Silicon IEEE 802.3bt, September 2014 1 Objectives To compile a list of use cases that the task force will consider to meet its objectives For purposes of discussion,

More information

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual INTRODUCTION Congratulations on your purchase of the VGA CAT-5 1:8 Distribution S. Your complete satisfaction

More information

HDBaseT Installation Guide

HDBaseT Installation Guide Installation Guide This document provides the best practices for installing Ethernet cable with setups. We strongly recommend to use ATEN certified cable (2L-2910) to provide best performance and to guarantee

More information

Telecommunications Service Technician

Telecommunications Service Technician Telecommunications Service Technician Telecommunications Service Technician This Construction Zone workstation will teach you the basic fundamentals of installing telecommunication cables, as you acquire

More information

OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE Round Messenger (ADSS) A round messenger fiber optic cable is designed for use in aerial installations

More information

2002, Cisco Systems, Inc. All rights reserved.

2002, Cisco Systems, Inc. All rights reserved. 2002, Cisco Systems, Inc. All rights reserved. 1 Panduit Network Infrastructure Essentials Chapter 8 Tools of the Trade Learning Objectives Learn about common tools used in the telecommunications cabling

More information

COPPER SYSTEMS The smart choice for delivering best-in-class performance across any application.

COPPER SYSTEMS The smart choice for delivering best-in-class performance across any application. COPPER SYSTEMS The smart choice for delivering best-in-class performance across any application. Atlas-X1 extreme GigaMax Copper Systems Leviton copper systems combine industry-leading performance with

More information

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors PPLINCES /// MT, CST-100 II ND SL-156 CONNECTORS CONNECTORS/ PPLINCES MT, CST-100 II and SL-156 Connectors Contents Introduction This catalog has been designed to assist you, our customer, identify products

More information

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber The Road to Single Mode: Direction for choosing, installing and testing single mode fiber Adrian Young Leviton Network Solutions Jim Davis Fluke Networks Adrian Young, Sr. Applications Engineer Leviton

More information

SECTION CONTROL, COMMUNICATION AND SIGNAL WIRING

SECTION CONTROL, COMMUNICATION AND SIGNAL WIRING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 27 10 00 CONTROL, COMMUNICATION AND SIGNAL WIRING SPEC WRITER NOTES: 1. Edit this specification section between // //, to fit project, or delete if not applicable.

More information