INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

Size: px
Start display at page:

Download "INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN"

Transcription

1 INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN 1.1 TECHNICAL DATA PRODUCT DESCRIPTION Screens made with the following projection fabrics: SOFT WHITE, MATT WHITE SOFT, SOFT WHITE TRANSOUND, RETRO (see technical pages 5/6/7) In the standard version, the screen is lowered from the front side of the box, by wall installation the fabric will descend at a distance from the same of mm 81.5 to 97.5, on request, the screen can be provided with rear lowering system, in this case the fabric will be at a wall distance of approximately 22.5 to 16.5 mm - Screen case of extruded aluminium, powder coated in white RAL 9010, section 85x93 mm with rounded corners on the upper ribs suitable for the fixation of hooking brackets; on the bottom part longitudinal slot with rounded edges, through which the projection fabric descends, Internal tube for the screen rewinding, of anodized aluminium silver Ø 60 mm, which incorporates the electric motor on special silent-block rubber Single phase electric motor, IMQ, CE, 5- year warranty from date of purchase, supply 200V - 50Hz, 0.5 A absorption, degree of protection IP 44, 17 RPM, in the standard version the motor is mounted on the left side screen up and down electric inverter standard supplied. Screen up and down limit switches factory adjusted, possibility of different settings if necessary. The screen can also be stopped at intermediate height by pressing the electric inverter switch - Suspension brackets are standard supplied and can be mounted anywhere along the whole housing length. Brackets are steel made, epoxy powder coated in white RAL 9010, suitable both for wall or ceiling installation thanks specific expansion anchors - Screen case end caps steel epoxy coated in white RAL 9010 Robust individual packing in double cardboard type Volcano - Product CE certified, full warranty 24 months as specified on the operating and maintenance manual- Optional accessories: radio remote control, spacing brackets - Box dimensions: size of the base of the canvas +7 cm 1

2 1.1.1 ELECTRIC CONTROL MOTOR SINGLE PHASE Standard voltage 230 V - 50 HZNormal power 120 W Power consumption 0.5 A Degree of protection IP rpm Normal torque 6 Nm Approval "IMQ" ELECTRIC UP-DOWN INVERTER 10 A Section output engine cables N. 4 x 1,5mq Power supply cable PHASE + NEUTRAL + EARTH sect. 1,5 mm POWER SUPPLY 220 VOLT - 50 HERTZ REMOTE CONTROL (if any) Operating frequency: Mhz Coding System: self code learning N. of codes to be memorized: 1000 for each receiver Capacity (BROWN) Impedance 50 Ohm Receipt range capacity: 40 m ca. (Please note that the value is to be considered guidance and can be influenced by barriers, metal structures, electromagnetic fields etc.). - Supply voltage 230 V aprox. - Power consumption 1.5 W MAX - Operating temperature - 10 to + 55 C 2

3 1.1.4 ELECTRICAL WIRING DIAGRAM FOR INVERTER SWITCH MOTORE = MOTOR POWER MORSETTI = WIRING TERMINALS 2 BLUE 3 YELLOW GREEN 4 BLACK OR BROWN 5 BLACK OR BROWN 1 PHASE 2 NEUTRAL 3 GROUND - Disconnect mains power prior to any operation - After installation you should not operate any traction on the terminals - Connect the grounding wires before the phase and neutral 3

4 1.1.5 WIRING FOR REMOTE CONTROL To install the unit, proceed as follows: a) prepare the Jumper b) connect the power supply and the motor (with the limit switches) c) if required, connect the manual wall switches open/close 4

5 1.2 PROJECTION FABRIC PVC projection fabric, thickness 400 MY, height. 2400, cadmium free, type fire proof class M1, as per french definition and in compliance with EEC 91/338. Light white colour with a smooth side, rear of the screen not to be used and a satin finish side for projections. In the standard version, front screen lowering from the screen case, consequently wall distance about mm in the case of wall fixation, on request, it can be supplied with rear lowering system, in this case wall distance will be mm to The projection canvas is rolled on a silver anodized round aluminium tube, section dia.mm.60, which integrates the electric motor. For best viewing, it is recommended to unroll the screen at least few hours before projection start to allow the canvas to perform its best planarity. FRONT LOWERING (WALL DISPLACED) REAR LOWERING (CLOSE TO THE WALL) 5

6 1.3 ALUMINIUM CASE Extruded aluminium casing powder coated in light grey RAL 7035, section mm. 85x93 with rounded corners, upper ribs with appropriate hooking brackets, longitudinal slot with rounded edges, through which the projection canvas is lowered, on the bottom left side of the screen case, two holes enable the access to the canvas raising/lowering adjustment screws. 2.0 SAFETY 2.1 SAFETY CRITERIA ADOPTED The cables supplied are contained in a single housing of self-extinguishing plastic, however, wall or ceiling mounting must comply with the law 46/90 and be conducted by appropriate staff. In case of failure of one of the two limit adjustment screws, on the electric motor, there is a thermal switch capable to open the electrical circuit. The whole equipment was designed for maximum safety. 2.2 SAFETY COMPONENTS The adopted safety components are: Robust suspension brackets widely oversized thermal electric switch in case of failure of one of the two limits. No sharp corners or sharp edges which could cause injury 6

7 3.0 INSTALLATION The installation of this type of screens can be to wall or to the ceiling. 3.1 INSTALLATION INSTRUCTION To make a correct installation, position the two suspension brackets in such a way that the screen is suspended about 1 / 15 of its length, measured from one of the two terminal heads. Fix the brackets to obtain an alignment as accurate as possible. Use reliable anchors and appropriate to the wall, minimum recommended size diameter mm. 8. IMPORTANT! Make sure that wall or ceiling are appropriate to support the declared weight and to the installation through screw anchors. When in doubt, use chemical fixings type. Once brackets are fixed, lift up the screen and attach it on the appropriate tab of the bracket, then slightly tighten the front screw and tighten the lock bolt. This must be done by two people, one from the left side, the other from the right side. IMPORTANT! Choose walls with a flat surface, otherwise the bracket tag will not ensure the suspension of the screen. 7

8 4.0 OPERATION 4.1 GENERAL DESCRIPTION After the electrical connections, make sure of the exact voltage of the power supply, close the circuit and giving power and operate with short pulses on the inverter "Lowering." Make sure everything runs properly and then operate few times the up/down mechanism. At this point the operation was well performed. 5.0 USE 5.1 SETTING THE LIMIT SWITCHES The only adjustment to be made is that of the two up and down switches up of the projection screen. These two elements are already set during production, by the manufacturer. However, you can make some adjustments by turning the two limit switches screws, which can be reached by introducing a 4 mm hexagonal key standard supplied - in the two holes on the bottom of the screen case. IMPORTANT! Do not unroll the canvas over the measurement specified for each type of screen: increasing the descent above this size could damage the screen or cause its fall off, such damages are not covered by warranty and are not under the responsibility of the manufacturer. Likewise, do not force the rewinding of the canvas after it has been completely rolled up as this would force the electric motor and the counter weight tube could get stacked into the box and consequently get damaged. 8

9 Setting the upper limit switch - Bring the canvas to the maximum upper position, then stop the movement by pressing STOP button (centre position) - Insert the 4 mm hexagonal screw (standard supplied) in the 1st hole near the opening of the descent of the canvas, turn the screw counter-clockwise = more winding-up, clockwise = less winding-up. Each turn of the screw is approximately mm. 35 displacement of the canvas. Setting the lower limit switch - Bring the canvas to the maximum lower position, then stop the movement by pressing STOP button (centre position) - Insert the 4 mm hexagonal screw (standard supplied) in the 2nd hole (the farthest one from the canvas), turn the screw counter-clockwise = more descent, clockwise = less descent. DISCESA = DOWN SALITA = UP LATO PROIEZIONE = PROJECTION SIDE 9

10 5.2 RECOMMENDATIONS AND PROHIBITION It is forbidden the use of the screen by persons below 16 years of age or disabled or otherwise altered in their operational ability. It also prohibited the installation on precarious, unstable and uneven walls. Environments with high humidity, dusty, in the presence of explosive mixtures. It is not recommended the screen continue exposure to sunlight, which could alter the original colour of the canvas. Do not expose the screen to temperatures above 50 C, this could cause irreparable damages. In case of malfunction of the motor, do not force manually the output of the canvas, but call service. Do not adjust the limit switches continuously and without any real necessity. 10

CINEDOMUS PROJECTION SCREENS with electrical command, varnished aluminium case

CINEDOMUS PROJECTION SCREENS with electrical command, varnished aluminium case CINEDOMUS PROJECTION SCREENS with electrical command, varnished aluminium case CINEDOMUS is the new range of professional electrical screens, developed and designed mainly for domestic use in home cinemas,

More information

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width Before installing the screen winch system, please read the following instructions carefully: The screen winch system must be used

More information

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width Before installing the screen winch system, please read the following instructions carefully: The screen winch system

More information

TENSIONED ELPRO CONCEPT Motorized projection screen for wall or ceiling installations

TENSIONED ELPRO CONCEPT Motorized projection screen for wall or ceiling installations Motorized projection screen for wall or ceiling installations Watch the video: Product specifications: Electrically operated projection screen 230 volt (50Hz) with a usage of no more than 0.53 Ampere (121.9

More information

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width Before installing the screen winch system, please read the following instructions carefully: The screen winch system must be used

More information

Electric Motorized Projection Screen PowerMax Tension Series

Electric Motorized Projection Screen PowerMax Tension Series Electric Motorized Projection Screen PowerMax Tension Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The screen

More information

Electric Motorized Projection Screen Spectrum Tab-Tension Series User s Guide

Electric Motorized Projection Screen Spectrum Tab-Tension Series User s Guide Electric Motorized Projection Screen Spectrum Tab-Tension Series User s Guide Important Safety Precautions Make sure to read this user s guide and follow the procedures below prior to screen operation.

More information

Caution. Hanging the Screen:

Caution. Hanging the Screen: Installation Instructions for Laminar and Laminar XL Projection Screens Caution 1. Read Instructions through completely before proceeding; keep them for future reference. Follow these instructions carefully.

More information

Motor Operated Solar Shade with Valance Installation and Care Instructions Complete Video Instructions Available Online at

Motor Operated Solar Shade with Valance Installation and Care Instructions Complete Video Instructions Available Online at * Motor Operated Solar Shade with Valance Installation and Care Instructions Complete Video Instructions Available Online at www.keystonefabrics.com Step 1: Identify the parts of your shade (parts shown

More information

Digital Clock with Second Circle DA Series

Digital Clock with Second Circle DA Series Digital Clock with Second Circle DA Series State of art technology digital clock intended to be used indoors the clock will find use in many applications, in radio or television studios or as wall clock

More information

DLP200M 2 Relay Module for Heating and Cooling Plants

DLP200M 2 Relay Module for Heating and Cooling Plants Product Sheet TH6.24 Thermostat Type DLP200M DLP200M 2 Relay Module for Heating and Cooling Plants The DLP 200 M is a relay module for activation of loads (namely thermal actuators or circulators) in wireless

More information

INSTALLATION INSTRUCTIONS FOR

INSTALLATION INSTRUCTIONS FOR INSTALLATION INSTRUCTIONS FOR MODEL 2240LED www.sportablescoreboards.com 1 Table of Contents 8 X 7 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR

More information

Installation Guide VL-MV10. Model No.

Installation Guide VL-MV10. Model No. Installation Guide Model Name Model No. Main Monitor Station VL-MV0 R Main monitor station is described as "main monitor" in this guide. R In this guide, the suffix of each model number (e.g., the "EX"

More information

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide In-Ceiling Electric Motorized Front Projection Screen Evanesce Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The

More information

DLP600M 6+1 Relay Module for Heating and Cooling Plants

DLP600M 6+1 Relay Module for Heating and Cooling Plants Product Sheet TH6.25 Thermostat Type DLP600M DLP600M 6+1 Relay Module for Heating and Cooling Plants The DLP 600 M is a relay module for activation of loads (namely thermal actuators or circulators) in

More information

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED INSTALLATION INSTRUCTIONS FOR MODEL 2230LED www.sportablescoreboards.com 1 Table of Contents MODEL 2230LED... 3 8 X 4 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:...

More information

Starling Tab-Tension 2 Series

Starling Tab-Tension 2 Series Electric Wall/Ceiling Projection Screen Starling Tab-Tension 2 Series For: Spectra White FG and CineGrey 5D User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow

More information

Electric Wall/Ceiling Projection Screen Saker Tab-Tension Series User s Guide

Electric Wall/Ceiling Projection Screen Saker Tab-Tension Series User s Guide Electric Wall/Ceiling Projection Screen Saker Tab-Tension Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The screen

More information

Horn loudspeaker, Ex proof, short/long flare

Horn loudspeaker, Ex proof, short/long flare Horn loudspeaker, Ex proof, short/long flare LH3 UC25XS, LH3 UC25XL en Installation note Horn loudspeaker, Ex-proof, short/long flare Installation en 3 1 Installation 1 2 Figure 1.1 Figure 1.2 4X Figure

More information

Pendant Light Fitting IEC Series 6470/2

Pendant Light Fitting IEC Series 6470/2 > Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E

More information

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A 1 414 P The 414 P automated system for swing leaf gates is an electromechanical operator which transmits motion to the leaf by a worm-screw system. It is a self-locking automatic system equipped with a

More information

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD 1 INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD NOTE TO INSTALLERS: PLEASE RETURN THIS MANUAL TO THE INDIVIDUAL IN CHARGE OF THE SCOREBOARD UPON COMPLETION OF INSTALLATION. The scoreboard

More information

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Model DT-311J And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL 1. GENERAL The DT-311J DIGITAL

More information

Operation and Maintenance Guide Electric Needle Scalers

Operation and Maintenance Guide Electric Needle Scalers Operation and Maintenance Guide Electric Needle Scalers Models Covered Model Number ENS100V ENS200V Electric Needle Scaler, 110V-1ph Electric Needle Scaler, 220V-1ph Description IMPA Number 59 12 01 59

More information

Electric projection screen Avers Cumulus

Electric projection screen Avers Cumulus Electric projection screen Avers Cumulus User s manual Read these instructions carefully before operating the screen. Dear Customer, Thank you very much for the purchase of our product. The manual booklet

More information

User Manual. Tensioned Screens. Website: Tel:

User Manual. Tensioned Screens. Website:    Tel: User Manual Tensioned Screens Website: www.luxburgvisual.com Email: support@luxburgvisual.com Tel: 0044 207 237 4842 Table of Contents SAFETY INFORMATION... 3 IMPORTANT SAFETY INSTRUCTION... 3 SETTING

More information

Backlight Replacement

Backlight Replacement Installation Instructions Backlight Replacement Catalog Numbers 2711P-RL7C, 2711P-RL7C2, 2711P-RL10C, 2711P-RL10C2, 2711P-RL12C, 2711P-RL12C2, 2711P-RL15C Topic Page About This Publication 1 Important

More information

TRF STEP-DOWN TRANSFORMER USER MANUAL

TRF STEP-DOWN TRANSFORMER USER MANUAL TRF STEP-DOWN TRANSFORMER USER MANUA www.ventilation-system.com 2013 ! WARNING The present operation manual consisting of the technical details, operating instructions and technical specification applies

More information

Electric projection screen Avers Solaris

Electric projection screen Avers Solaris Electric projection screen Avers Solaris User s manual Read these instructions carefully before operating the screen. Dear Customer, Thank you very much for the purchase of our product. The manual booklet

More information

AMERICAN NATIONAL STANDARD

AMERICAN NATIONAL STANDARD Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 129 2017 Drop Passives: Bonding Blocks (Without Surge Protection) NOTICE The Society of Cable Telecommunications Engineers (SCTE) Standards

More information

Modular pulse operated latching relay 16 A

Modular pulse operated latching relay 16 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,

More information

Enterview 2 / Enterview 2V 4 WIRE VIDEO DOORPHONE SYSTEM

Enterview 2 / Enterview 2V 4 WIRE VIDEO DOORPHONE SYSTEM Enterview / Enterview V WIRE VIDEO DOORPHONE SYSTEM INSTALLATION AND OPERATION. Introduction This Video doorphone System is an easy-to-use system offering many benefits and conveniences, such as relieving

More information

10 PDUs 19 PDUs Zero-U PDUs

10 PDUs 19 PDUs Zero-U PDUs 128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex - France Tel: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 www.legrand.com 10 PDUs Page 1. GENERL CHRCTERISTICS...1 2. EQUIPMENT ND PERFORMNCE...3

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX 2562089B REV. B 110 Printed in U.S.A. MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

More information

lumenfacade Specification Sheet

lumenfacade Specification Sheet Client Project name Order# Type Qty FEATURES AND BENEFITS Physical : Low copper content extruded aluminum housing Electro-statically applied polyester powder coat finish Machined aluminum end caps and

More information

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV REV. 1.0 Fully ly Automaticti Motorised Satellite t TV System User s manual Customer Help Line: 1300 139 255 Support Email: support@satkingpromax.com.au Website: www.satkingpromax.com.au www.satkingpromax.com.au

More information

Linealux L5 Linear Facade

Linealux L5 Linear Facade The Linealux L5 is a high power architectural grade luminaire that combines technology and performance in a stylish linear form factor. Available in white, colour changing and tunable white light engines,

More information

3M Distribution Box (DDB)

3M Distribution Box (DDB) 3M Distribution Box (DDB) Merged Copper and Fiber Pole/Post Mount Enclosure Installation Instructions November 2015 78-0015-2736-1-A 2 November 2015 78-0015-2736-1-A Contents 1.0 General 2.0 Enclosure

More information

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA Operating Manual Automated Gear Apollo Design Technology, Inc. 4130 Fourier Drive Fort Wayne, IN 46818 USA PH: +01(260)497-9191 FX: +01(260)497-9192 www.apollodesign.net 11-25-09 5-6 POWERING UP THE RIGHT

More information

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION. STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION. GENERAL. A.) Overview. 1) The Television Fresnel fixture shall be purpose designed for television and studio lighting applications.

More information

USER MANUAL. GOLDMUND LOGOS 1N-2N SPEAKER SYSTEM Active Speaker

USER MANUAL. GOLDMUND LOGOS 1N-2N SPEAKER SYSTEM Active Speaker USER MANUAL GOLDMUND LOGOS 1N-2N SPEAKER SYSTEM Active Speaker Thank you for purchasing the Goldmund LOGOS 1N-2N SPEAKER SYSTEM The Goldmund Logos line fully incorporates the technological expertise developed

More information

Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide

Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The screen s

More information

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number: USERS GUIDE MCX-HTS HDMI to 3G SDI Converter i Manual Number: 151226 SAFETY INSTRUCTIONS Please review the following safety precautions. If this is the first time using this model, then read this manual

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

PRJTPFL inch PRJTPFL inch PRJTPFL inch. Fixed Wall Mount Projector Screen. Universal Home/Office Projector Viewing Display

PRJTPFL inch PRJTPFL inch PRJTPFL inch. Fixed Wall Mount Projector Screen. Universal Home/Office Projector Viewing Display PRJTPFL102-100 - inch PRJTPFL112-110 - inch PRJTPFL122-120 - inch Fixed Wall Mount Projector Screen Universal Home/Office Projector Viewing Display Be sure to read this manual before use so you will know

More information

ASP-FIBRS1 User Manual

ASP-FIBRS1 User Manual ASP-FIBRS1 HDMI Single Fiber Extender with Serial and IR User Manual Manual Number: 100823 Safety and Notice The ASP-FIBRS1 HDMI Extender over 1 fiber with serial and IR have been tested for conformance

More information

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions Timer Modules EL11 24 Hour Module EL17 7 Day Module Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference and maintenance.

More information

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010 Operating instructions Retro-reflective sensor OJ50xx laser 70481 / 00 05 / 010 Contents 1 Preliminary note3 1.1 Symbols used 3 Safety instructions 3 4 Installation 4 4.1 Installation of the supplied mounting

More information

Tube Rotator. User Guide. Version 1.2

Tube Rotator. User Guide. Version 1.2 Tube Rotator User Guide Version 1.2 Figure 1: Fixed Speed Model Tube holder spindle Tilt adjustment wheel IEC power inlet socket (at rear) Power on/off switch Figure 2: Variable Speed Model Tube holder

More information

Operating instructions

Operating instructions 108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.

More information

MICROMASTER Encoder Module

MICROMASTER Encoder Module MICROMASTER Encoder Module Operating Instructions Issue 01/02 User Documentation Foreword Issue 01/02 1 Foreword Qualified Personnel For the purpose of this Instruction Manual and product labels, a Qualified

More information

LED Driver Compact dimming

LED Driver Compact dimming Driver CA 15W 180-350mA flexc PH-C SR ADV ADVACED series Product description Dimmable constant current ED Driver (SEV) Independent ED Driver with cable clamps Selectable output current between 180, 250

More information

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver 27.3.2012 1(12) CXX Series User Manual Teleste Corporation CXE810 Fibre optic receiver 27.3.2012 2(12) Contents Introduction... 3 Installation... 3 Housing... 3 Powering... 4 Interfaces... 4 Fibre installation...

More information

Important Safety & Warning Precautions

Important Safety & Warning Precautions Electric Motorized Projection Screen VMAX 2 Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedure below. Caution: The screen s Black Top

More information

Unlocking of building entrance door shall be possible by pressing the monitor's door-opener button.

Unlocking of building entrance door shall be possible by pressing the monitor's door-opener button. DIGITAL COLOR VIDEO INTERCOM SYSTEM The contractor shall supply, install, test and commission a modern Electronic Digital Color Video Entry Phone System of an approved manufacturer and design to facilitate

More information

EXPlora. Introduction

EXPlora. Introduction Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

TIMETRAX SYNC RF WIRELESS DIGITAL CLOCK Installation Instructions

TIMETRAX SYNC RF WIRELESS DIGITAL CLOCK Installation Instructions Installation Instructions OVERVIEW Thank you for choosing a TimeTrax Sync RF Wireless Clock System. The TimeTrax RF Wireless Clock System receives dependable, accurate time from the TimeTrax Sync RF Wireless

More information

Optical Signal Devices. Free-standing Beacons

Optical Signal Devices. Free-standing Beacons Free-standing Beacons Overview Free-standing Permanent Beacons Flashing Beacons 200/203 201/204 (LED) 209 209 (LED) 210/213 211/214 (LED) 219 219 (LED) 202 Flashing 205 Flashing 209 Flashing Beacon 212

More information

FOREST SHUTTLE S / L / M RECEIVER

FOREST SHUTTLE S / L / M RECEIVER 2 FOREST SHUTTLE S / L / M RECEIVER QUICK INSTALLATION OF ASSEMBLED TRACKS : Programming Shuttle S / L / M Receiver to a channel One pre-assembled motorized curtain track systems is standard programmed

More information

3 Cleaning. 4 Technical data

3 Cleaning. 4 Technical data EXC+ EXC- Sig- SIG+ SEN- SEN+ 2.4 Attaching cable to the analog board Attaching cable of the weighing cell to the system solution Connect the cable to the appropriate terminal strip of the Ex1 system solution

More information

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS GENERAL DESCRIPTION The SM-1100, SM-1500 and SM-1600 Series are multi-turn, rotary actuators, designed to meet the exacting requirements for closed-loop modulating

More information

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features: ENCODER Incremental Angle Transducer Series A36, A58 Key-Features: Content: Technical Data A36...2 Technical Data A58...4 Elektrical Data...6 Accessories...7 Measuring Wheels...8 Order Code...9 - Incremental

More information

INSTRUCTION MANUAL [J] [E] [C] [G] [B] [I] [H] [D] [F] [A] 0 INTRODUCTION 1 RECOMMENDATIONS 2 ACCESSORIES INCLUDED

INSTRUCTION MANUAL [J] [E] [C] [G] [B] [I] [H] [D] [F] [A] 0 INTRODUCTION 1 RECOMMENDATIONS 2 ACCESSORIES INCLUDED 0 INTRODUCTION Video Lift is an electro-mechanical device which, once installed in the ceiling, allows vertical movement (ceiling floor ceiling) for loads of up to 19 Kg and with maximum runs of 1 metre

More information

Indoor/Outdoor Security System with Quad Monitor User s Manual

Indoor/Outdoor Security System with Quad Monitor User s Manual Indoor/Outdoor Security System with Quad Monitor User s Manual 4919539 Important! Please read this booklet carefully before installing or using these units. WARNING - These units should ONLY be opened

More information

SQM40/41 Actuators for air and gas dampers

SQM40/41 Actuators for air and gas dampers SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The

More information

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71.

.152 (3.86) KEYWAY DEPTH .033 (.84).066 (1.68) .550 DIA (13.97) MOUNTING SURFACE .350 (8.89) 3/8-32 UNEF-2A THREADS (19.71. Optical SERIES 61K High Resolution, 4-Pin FEATURES 25, 32, 50, 64, 100, 128 and 256 Cycles per Revolution Available Sealed Version Available Rugged Construction Cable or Pin Versions 10 Million Rotational

More information

Safety Light Curtains GuardShield

Safety Light Curtains GuardShield Description The Allen-Bradley Guardmaster safety light curtain is an economical, fully featured, Type 4 safety light curtain in a uniquely styled housing. safety light curtains are general purpose presence

More information

Electric Wall/Ceiling Projection Screen Saker Series User s Guide

Electric Wall/Ceiling Projection Screen Saker Series User s Guide Electric Wall/Ceiling Projection Screen Saker Series User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow the procedures below. Caution: The screen s Black

More information

Fiber Optic Splice Closure GPJ Instruction Manual

Fiber Optic Splice Closure GPJ Instruction Manual Fiber Optic Splice Closure GPJ09-9401 Instruction Manual 1. Brief Introduction GPJ09-9401 type of Fiber Optic Splice Closure is a member in dome series, the main function is to provice direct pass, branch

More information

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! USER MANUAL DE-1 Police-light CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing! For your own safety, please read this user manual carefully before you

More information

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex. Guide for installers METTLER TOLEDO MultiRange System solution Point Ex www.mt.com/support System solution Point Ex Contents Contents Page 1 Safety precautions... 4 2 System overview... 5 2.1 Using the

More information

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA Hinges with built-in safety multiple switch SUPER ECHNO POLYMER IP RoHS PA +0-0 MAERIAL Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black or grey colour RAL 00 (C). Rotation pin: glass-fibre

More information

Tube Roller Shakers. User Guide. Version 1.2

Tube Roller Shakers. User Guide. Version 1.2 Tube Roller Shakers User Guide Version 1.2 Control panel Rollers Side retaining panels Analog models LED display Drip tray (not visible) Digital models Power On/Off and control dial Roller retaining panel

More information

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical

More information

OM2000N INSTALLATION MANUAL

OM2000N INSTALLATION MANUAL OM2000N INSTALLATION MANUAL 2 1 Figure A 1 2 Laser Beam Output Window Power Cable 821001342 (Rev. B) DESCRIPTION The OM2000N oscillating mirror is an accessory for the 2000N family laser scanners: DS2100N,

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR 28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR INSTRUCTION MANUAL Please read this manual thoroughly before use, and keep it handy for future reference. TABLE OF CONTENTS 1, General information...

More information

ARS x4 MATRIX SWITCHER Instruction Manual

ARS x4 MATRIX SWITCHER Instruction Manual ARS-8400 8x4 MATRIX SWITCHER Instruction Manual Thank you for purchasing one of our products. Please read this manual before using this product. When using this product, always follow the instructions

More information

Orbit TM DIGITAL SHAKERS

Orbit TM DIGITAL SHAKERS Orbit TM DIGITAL SHAKERS INSTRUCTION MANUAL Models P2, P4, M60, 300, 1000, 1900 Labnet International PO Box 841 Woodbridge, NJ 07095 Phone: 732 417-0700 Fax: 732 417-1750 email: labnet@labnetlink.com 2

More information

QWCD35/ QWCD35SD QWCD50/ QWCD50SD

QWCD35/ QWCD35SD QWCD50/ QWCD50SD LED Strobe Light and Alarm Sounder Combinations QWCD/ QWCDSD / SD -0~+60-0~+0 8 66 HORN Thank you for purchasing Qlight s products. Please read this user manual carefully prior to installation and operation

More information

Signal Tower KombiSIGN 70

Signal Tower KombiSIGN 70 Signal Towers modular Signal Tower This is how you can assemble your signal tower! STEP 1 Select the required optical or audible elements. Many KombiSIGN highlights are also available (for details see

More information

PERFECT Operating and Installation Manual

PERFECT Operating and Installation Manual PERFECT 2020 Operating and Installation Manual PERFECT 2020 Time recorder Manual for the operation and installation of the time recorder Copyright ISGUS J Schlenker-Grusen GmbH 2001-2007 The company ISGUS

More information

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1

More information

Figure 1: Device components

Figure 1: Device components Order No. : 2860 10 Order No. : 2830 10 Operation- and Assembly Instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe

More information

Flat-Bed Module Recorders

Flat-Bed Module Recorders Flat-Bed Module Recorders Model No. 08376-50 08376-55 08376-60 0115-0192 4/28/00 Table of Contents Introduction...3 Power Requirements...3 Chart Paper Installation...3 Pen Installation...5 Grounding...5

More information

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

ISP-W 350 till 1200 ISP-R 350 till 1200 ISP-B 350 till 1200 ISP-Motiv 450 till 950 with receiver RF Edition: 05/16 Nr

ISP-W 350 till 1200 ISP-R 350 till 1200 ISP-B 350 till 1200 ISP-Motiv 450 till 950 with receiver RF Edition: 05/16 Nr Installation and technical manual ISP-W / R / B / motives frameless with receiver RF 2 3 ISP-W 350 till 1200 ISP-R 350 till 1200 ISP-B 350 till 1200 ISP-Motiv 450 till 950 with receiver RF Edition: 05/16

More information

NewScope-7A Operating Manual

NewScope-7A Operating Manual 2016 SIMMCONN Labs, LLC All rights reserved NewScope-7A Operating Manual Preliminary May 13, 2017 NewScope-7A Operating Manual 1 Introduction... 3 1.1 Kit compatibility... 3 2 Initial Inspection... 3 3

More information

EC Series Creativity Accessories Safety and Installation Guide

EC Series Creativity Accessories Safety and Installation Guide EC Series Creativity Accessories Safety and Installation Guide Safety precautions Warning! Before installing Martin EC Series video panels using the accessories described in this guide, read the Safety

More information

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs User Manual 360W LED Moving Zoom 36pcs10W 4 in 1 RGBW LEDs KEEP THIS MANUAL FOR FUTURE NEEDS 1. Dispacking Thank you for choosing our moving head. For your own safety, please read this manual before installing

More information

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min Weekly Time Switch Easy Programming with Large LCD Display and Interactive Functions Programming for 24 hrs x 7 days using just five switches. Sixteen program steps available. Power supply freely selectable

More information

llen-bradley 194R-HM4-NFPA3

llen-bradley 194R-HM4-NFPA3 Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection

More information

PLL1920M LED LCD Monitor

PLL1920M LED LCD Monitor PLL1920M LED LCD Monitor USER'S GUIDE www.planar.com Content Operation Instructions...1 Safety Precautions...2 First Setup...3 Front View of the Product...4 Rear View of the Product...5 Installation...6

More information

prestigerange ORDER HOTLINE FREEPHONE Aluminium notice board specification and prices

prestigerange ORDER HOTLINE FREEPHONE Aluminium notice board specification and prices Price list issue 8 is a trading name of Signs of Cheshire Limited registered in England. Registered Address; 432 London Road Northwich Cheshire CW9 8EF prestigerange 95mm deep aluminium notice boards Choice

More information

NEPTUNE PROJECTION SCREEN PRO-LINE MANUAL SCREEN NEPTUNE PRO-LINE MNAUAL SCREEN SPRING ROLL LOCKING SYSTEM DEFINITE ASPECT UNIQUE APPEARANCE DURABLE

NEPTUNE PROJECTION SCREEN PRO-LINE MANUAL SCREEN NEPTUNE PRO-LINE MNAUAL SCREEN SPRING ROLL LOCKING SYSTEM DEFINITE ASPECT UNIQUE APPEARANCE DURABLE NEPTUNE PRO-LINE MANUAL SCREEN QS Neptune pro-line manual screen combines comfortable viewing and simplicity in use. It satisfies the most exacting viewers with clear black border for definite aspect.

More information

Manual GA450. V. 2.2 Fast & Fluid Management B. V. PO Box AE Sassenheim The Netherlands

Manual GA450. V. 2.2 Fast & Fluid Management B. V. PO Box AE Sassenheim The Netherlands Manual GA450 V. 2.2 Fast & Fluid Management B. V. PO Box 220 2170 AE Sassenheim The Netherlands www.fast-fluid.com Fast & Fluid Management B.V. This manual or parts thereof may not be reproduced, stored

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information