Capstone Experiment Setups & Procedures PHYS 1111L/2211L

Size: px
Start display at page:

Download "Capstone Experiment Setups & Procedures PHYS 1111L/2211L"

Transcription

1 Capstone Experiment Setups & Procedures PHYS 1111L/2211L Picket Fence 1. Plug the photogate into port 1 of DIGITAL INPUTS on the 850 interface box. Setup icon. the 850 box. Click on the port 1 plug in Digital Inputs. 5. Choose Picket Fence. 7. The Record button should the photogate can collect 8. To choose a data collection page template, click on the table & graph icon. 9. Add two columns to the table by clicking on this icon twice. 10. The table columns will contain time, position, speed, & acceleration Click on <Select Measurements> of the first column and choose Time. 11. Click on <Select Measurement> of the second column and choose Position. 12. Likewise, assign the third and fourth columns to display speed and acceleration. 13. The graph will display velocity vs time. Click on the <Select Measurements> of the vertical axis and choose Speed. The horizontal axis should automatically set to Time. 14. Since speed is plotted vs time, the slope of this graph is acceleration. You can fit the data to a straight line by clicking on the fit button and choosing linear. 15. When the experiment is finished, you Atwood s Machine 1. Plug the photogate into port 1 of DIGITAL INPUTS on the 850 Interface box. Setup icon. the 850 box. Click on the port 1 plug in Digital Inputs. 5. Choose Photogate With Pulley. 7. The Record button should the photogate can collect 8. Double click on the graph 9. Click <Select Measurement> on the vertical axis and choose Linear Speed.

2 10. When taking data, you will probably end up with spuriously points like the last ones in the figure below. You can avoid using those in your fit by clicking on the Highlight icon. This will give you a box that you can use to highlight only the data points that you want to use. 11. When the desired data are highlighted, click on the fit button and choose linear. Your plot should look something like the figure below. 1. Plug the yellow and black jack plugs of the motion sensor into ports 1 and 2 of the DIGITAL INPUTS on the 850 data collection box. the 850 box. Click on the port 1 plug in Digital Inputs. Choose Motion Sensor II. the Motion Sensor can collect 7. Double click on the graph 8. When the experiment is finished, you Friction 12. Since speed is plotted vs time, the slope of the line provides the acceleration. 13. When the experiment is finished, you Bouncing Ball 1. Plug the force sensor into the A port of the Analog Inputs on the 850 data collection box. Note that the 8 pin DIN connector must be inserted with the arrows on top. 2. Double click the Capstone icon to start the data collection 3. Click on the Hardware Setup icon. the 850 box. Click on the port A plug in Analog Inputs.

3 5. Choose Force Sensor. 7. The Record button should now be red, indicating that the photogate can collect 8. Double click on the graph icon (on the right-hand side of the window) to bring up 9. Click <Select Measurement> on the vertical axis and choose Force. 10. When running an experiment, be sure to begin pushing the force sensor lightly against the block and build up force slowly. When the block begins to move, try to push it along at a constant speed. 11. To find the average value of the kinetic friction measurements, click the Highlight button and frame just the desired 12. You can display the Mean of these data by clicking on the Statistics icon. Clicking on the pull-down menu on the Statistics icon will allow you to check Mean. 13. Your graph should look something like the figure below. 14. To find the static friction just before the block began to slide, you can expand the highlight box to include the peak of the graph, and then check Maximum in the Statistics pull-down menu. 15. When the experiment is finished, you Ballistic Pendulum Photogate 1. Plug the photogate into port 3 of DIGITAL INPUTS on the 850 interface box. the 850 box. Click on the port 3 plug in Digital Inputs. 5. Choose Photogate. 7. Click on the Timer Setup icon. 8. Since we ll use the Pre- Configured Timer, click Next. 9. Since we ll use a Photogate on Ch 3, click Next. 10. Click the Select a Timer dropdown menu and choose One Photogate (Single Flag). 11. In the next step, just the Speed box should be checked. Click Next. 12. Set the Flag Width to m. Click Next. This value is one inch, the diameter of the ball. 13. Click Finish. 14. The Record button should the photogate can collect 15. Click again on the Timer Setup icon to

4 16. Double click the Digits of the screen). This will produce a digital readout for measuring the speed of the ball through the photogate. 17. Click on <Select Measurements> and choose Speed. 18. With the photogate mounted on the ballistic pendulum using the Photogate Mounting Bracket, you can now measure the gun s muzzle velocity. 19. When the experiment is finished, you Rotational Dynamics 1. Plug the photogate into port 4 of DIGITAL INPUTS on the 850 interface box. the 850 box. Click on the port 4 plug in Digital Inputs. 5. Choose Photogate. 7. Click on the Timer Setup icon. 8. Since we ll use the Pre- Configured Timer, click Next. 9. Since we ll use a Photogate on Ch 4, click Next. 10. Click the Select a Timer dropdown menu and choose One Photogate (Single Flag). 11. In the next step, just the Speed box should be checked. Click Next. 12. Set the Flag Width to m. Click Next. 13. Click Finish. 14. The Record button should the photogate can collect 15. Click again on the Timer Setup icon to 16. Double click the Digits icon (on the right-hand side of the screen). This will produce a digital readout for measuring the speed of the ball through the photogate. 17. Click on <Select Measurements> and choose Speed. 18. With the Photogate mounted at the bottom of the ramp so that the beam is broken by the diameter of the ball, you can now measure the ball s speed at the ramp bottom, and determine its kinetic energy. 20. When the experiment is finished, you Simple Harmonic Motion 1. Plug the yellow and black jack plugs of the motion sensor into ports 1 and 2 of the DIGITAL INPUTS on the 850 data collection box. the 850 box. Click on the port 1 plug in

5 Digital Inputs. Choose Motion Sensor II. the Motion Sensor can collect 7. Double click on the graph 8. Click twice on the Add Plot Area icon in order to add two more graphs to your readout. 9. Click <Select Measurement> on the vertical axis of the top graph and choose Position. 10. Likewise, choose Velocity and Acceleration for the y axes of the other two graphs. 11. With the mass hanging from the spring over the motion sensor, you can now start the oscillation and record 5 to 10 seconds of 12. Since the motion is Simple Harmonic Motion, the position data should fit a sine function. Click on the position vs time graph and then click the Fit icon and choose Sine. 13. We d like to fit the sine curve over a subset of the data, so click the Highlight icon and expand the highlight box to include the first 5 seconds of position 14. The velocity graph values are derived from the position Click on it and fit a sine function to this graph. 15. Use the highlight tool to make sure that the fit extends over the same time range as the position fit. 16. The acceleration graph is derived from the velocity graph. Fit this to a sine curve, over the same time range. Your graphs should look something like the figure below. 17. When the experiment is finished, you Linear Expansion 1. Plug the thermistor sensor into port D of the ANALOG INPUTS in the 850 data collection box. Note that the 8 pin DIN connector must be inserted with the arrows on top. the 850 box. Click on the port D plug in ANALOG INPUTS, and choose Thermistor Temperature Sensor. 6. The Record button should now be red, indicating that the sensor can collect

6 7. Double click on the graph 8. Click <Select Measurement> on the vertical axis of the top graph and choose Temperature. 9. Connecting the thermistor sensor to the metal tube of the apparatus will allow its temperature to be monitored. 10. When the experiment is finished, you Specific Heat Capacity 1. Plug the temperature sensor into port B of the ANALOG INPUTS in the 850 data collection box. Note that the 8 pin DIN connector must be inserted with the arrows on top. the 850 box. Click on the port B plug in ANALOG INPUTS, and choose Temperature Sensor, Stainless Steel. A few of the temperature sensors in the lab room are of a different type, so if your temperature reading seems incorrect, it might be necessary to try choosing another type during this step. the sensor can collect 7. Double click on the graph graph in the main page. 8. Click <Select Measurement> on the vertical axis of the top graph and choose Temperature. 9. When the experiment is finished, you Resonance in Air Columns & Helmholtz Resonance 1. Plug the microphone into port C of the ANALOG INPUTS in the 850 data collection box. Note that the 8 pin DIN connector must be inserted with the arrows on top. the 850 box. Click on the port C plug in ANALOG INPUTS, and choose Sound Sensor. the microphone can collect 7. Double click on the FFT icon, which is along the right-hand side of the Capstone window. 8. Click <Select Measurement> on the vertical axis of the top graph and choose Sound Intensity. 9. At the bottom of the window is an adjustment for the

7 range of displayed frequencies. Adjust this so that the maximum displayed frequency is 2000 Hz. 10. When you play a tone with one of the tubes directly into the microphone, the primary frequency of the sound should be apparent in the spectrum. 11. Click on the Smart Tool icon. You can move this tool around the spectrum to determine the frequency of the features. 12. When the experiment is finished, you

8 Capstone Experiment Setups & Procedures PHYS 1112L/2212L Electrical Equivalent of Heat 1. Plug the temperature sensor into port B of the ANALOG INPUTS in the 850 data collection box. Note that the 8 pin DIN connector must be inserted with the arrows on top. the 850 box. Click on the port B plug in ANALOG INPUTS, and choose Temperature Sensor, Stainless Steel. A few of the temperature sensors in the lab room are of a different type, so if your temperature reading seems incorrect, it might be necessary to try choosing another type during this step. the sensor can collect 7. Double click on the graph 8. When the experiment is finished, you Diffraction 1.

E X P E R I M E N T 1

E X P E R I M E N T 1 E X P E R I M E N T 1 Getting to Know Data Studio Produced by the Physics Staff at Collin College Copyright Collin College Physics Department. All Rights Reserved. University Physics, Exp 1: Getting to

More information

Capstone screen shows live video with sync to force and velocity data. Try it! Download a FREE 60-day trial at pasco.com/capstone

Capstone screen shows live video with sync to force and velocity data. Try it! Download a FREE 60-day trial at pasco.com/capstone Capstone screen shows live video with sync to force and velocity data. Try it! Download a FREE 60-day trial at pasco.com/capstone If you use these PSCO USB interfaces in your lab, it s time for PSCO Capstone

More information

Activity P32: Variation of Light Intensity (Light Sensor)

Activity P32: Variation of Light Intensity (Light Sensor) Activity P32: Variation of Light Intensity (Light Sensor) Concept DataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win) Illuminance P32 Vary Light.DS P54 Light Bulb Intensity P54_BULB.SWS Equipment Needed

More information

Activity P27: Speed of Sound in Air (Sound Sensor)

Activity P27: Speed of Sound in Air (Sound Sensor) Activity P27: Speed of Sound in Air (Sound Sensor) Concept DataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win) Speed of sound P27 Speed of Sound 1.DS (See end of activity) (See end of activity) Equipment

More information

Spectrum Analyser Basics

Spectrum Analyser Basics Hands-On Learning Spectrum Analyser Basics Peter D. Hiscocks Syscomp Electronic Design Limited Email: phiscock@ee.ryerson.ca June 28, 2014 Introduction Figure 1: GUI Startup Screen In a previous exercise,

More information

Getting Started with the LabVIEW Sound and Vibration Toolkit

Getting Started with the LabVIEW Sound and Vibration Toolkit 1 Getting Started with the LabVIEW Sound and Vibration Toolkit This tutorial is designed to introduce you to some of the sound and vibration analysis capabilities in the industry-leading software tool

More information

think science Physics Apparatus for Universities 550 Universal Interface Designed by physics teachers for physics teachers

think science Physics Apparatus for Universities 550 Universal Interface Designed by physics teachers for physics teachers Physics Apparatus for Universities Look inside and see our new products, including: u 550 Universal Interface u Modern Physics Apparatus u PAScar Dynamics Systems The light bulb heats up and cools down

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Complete Fine Beam Tube System 1013843 Instruction sheet 10/15 SD/ALF If it is to be expected that safe operation is impossible (e.g., in case of visible damage), the apparatus is

More information

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity Print Your Name Print Your Partners' Names Instructions August 31, 2016 Before lab, read

More information

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Intelligent Pendulum Hardness Tester BEVS 1306 User Manual Please read the user manual before operation. PAGE 1 Content 1. Company Profile... 3 2. Product Introduction... 3 3. Operation Instruction...

More information

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition INTRODUCTION Many sensors produce continuous voltage signals. In this lab, you will learn about some common methods

More information

Arbor Scientific PO Box 2750 Ann Arbor, Michigan (800) Timer & Photogates 2.0 P Owners Manual

Arbor Scientific PO Box 2750 Ann Arbor, Michigan (800) Timer & Photogates 2.0 P Owners Manual Arbor Scientific PO Box 2750 Ann Arbor, Michigan 48108 www.arborsci.com (800) 367-6695 Timer & Photogates 2.0 P4-1450 Owners Manual Stopwatch 0.01 second resolution to 999999.99 seconds Count FCC Compliance

More information

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors. Brüel & Kjær Pulse Primer University of New South Wales School of Mechanical and Manufacturing Engineering September 2005 Prepared by Michael Skeen and Geoff Lucas NOTICE: This document is for use only

More information

Silver Mountain Targets V2 Software Reference Guide. July 22, 2015

Silver Mountain Targets V2 Software Reference Guide. July 22, 2015 Silver Mountain Targets V2 Software Reference Guide July 22, 2015 1. Setting up new targets for the first time If this is the first time using the e-targets on a target frame, you will need to create and

More information

Lab 2: A/D, D/A, and Sampling Theorem

Lab 2: A/D, D/A, and Sampling Theorem Lab 2: A/D, D/A, and Sampling Theorem Introduction The purpose of this lab is to explore the principles of analog-to-digital conversion, digital-to-analog conversion, and the sampling theorem. It will

More information

THE OPERATION OF A CATHODE RAY TUBE

THE OPERATION OF A CATHODE RAY TUBE THE OPERATION OF A CATHODE RAY TUBE OBJECT: To acquaint the student with the operation of a cathode ray tube, and to study the effect of varying potential differences on accelerated electrons. THEORY:

More information

Using an oscilloscope - The Hameg 203-6

Using an oscilloscope - The Hameg 203-6 Using an oscilloscope - The Hameg 203-6 What does an oscilloscope do? Setting up How does an oscilloscope work? Other oscilloscope controls Connecting a function generator Microphones audio signals and

More information

Experiment P32: Sound Waves (Sound Sensor)

Experiment P32: Sound Waves (Sound Sensor) PASCO scientific Vol. 2 Physics Lab Manual P32-1 Experiment P32: (Sound Sensor) Concept Time SW Interface Macintosh file Windows file waves 45 m 700 P32 P32_SOUN.SWS EQUIPMENT NEEDED Interface musical

More information

MachineryMate 800 operating guide Handheld vibration meter

MachineryMate 800 operating guide Handheld vibration meter MachineryMate 800 operating guide Handheld vibration meter Wilcoxon Sensing Technologies 20511 Seneca Meadows Parkway, Germantown MD 20876, USA Amphenol (Maryland), Inc d/b/a Wilcoxon Sensing Technologies

More information

Experiment: Real Forces acting on a Falling Body

Experiment: Real Forces acting on a Falling Body Phy 201: Fundamentals of Physics I Lab 1 Experiment: Real Forces acting on a Falling Body Objectives: o Observe and record the motion of a falling body o Use video analysis to analyze the motion of a falling

More information

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes

Product Manual MNX10015 / REV C MODEL SB142, SB242. Dual Output Series Switch Boxes Product Manual MNX10015 / REV C MODEL SB142, SB242 Dual Output Series Switch Boxes Contents Section I Overview Introduction.... 2 Description... 2 Section II Installation Mounting... 3 Electrical Connections...

More information

Experiment 9A: Magnetism/The Oscilloscope

Experiment 9A: Magnetism/The Oscilloscope Experiment 9A: Magnetism/The Oscilloscope (This lab s "write up" is integrated into the answer sheet. You don't need to attach a separate one.) Part I: Magnetism and Coils A. Obtain a neodymium magnet

More information

Manual of Operation for WaveNode Model WN-2m. Revision 1.0

Manual of Operation for WaveNode Model WN-2m. Revision 1.0 Manual of Operation for WaveNode Model WN-2m. Revision 1.0 TABLE OF CONTENTS 1. Description of Operation 2. Features 3. Installation and Checkout 4. Graphical Menus 5. Information for Software Expansion

More information

imso-104 Manual Revised August 5, 2011

imso-104 Manual Revised August 5, 2011 imso-104 Manual Revised August 5, 2011 Section 1 Getting Started SAFETY 1.10 Quickstart Guide 1.20 SAFETY 1.30 Compatibility 1.31 Hardware 1.32 Software Section 2 How it works 2.10 Menus 2.20 Analog Channel

More information

SC26 Magnetic Field Cancelling System

SC26 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC26 SC26 Magnetic Field Cancelling System Makes the ambient magnetic field OK for electron beam tools in 300 mm wafer fabs Real time, wideband cancelling from DC to > 9 khz fields

More information

THE OPERATION OF A CATHODE RAY TUBE

THE OPERATION OF A CATHODE RAY TUBE THE OPERATION OF A CATHODE RAY TUBE OBJECT: To acquaint the student with the operation of a cathode ray tube, and to study the effect of varying potential differences on accelerated electrons. THEORY:

More information

Torsional vibration analysis in ArtemiS SUITE 1

Torsional vibration analysis in ArtemiS SUITE 1 02/18 in ArtemiS SUITE 1 Introduction 1 Revolution speed information as a separate analog channel 1 Revolution speed information as a digital pulse channel 2 Proceeding and general notes 3 Application

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar

More information

Pre-processing of revolution speed data in ArtemiS SUITE 1

Pre-processing of revolution speed data in ArtemiS SUITE 1 03/18 in ArtemiS SUITE 1 Introduction 1 TTL logic 2 Sources of error in pulse data acquisition 3 Processing of trigger signals 5 Revolution speed acquisition with complex pulse patterns 7 Introduction

More information

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO) 2141274 Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University Cathode-Ray Oscilloscope (CRO) Objectives You will be able to use an oscilloscope to measure voltage, frequency

More information

1 Ver.mob Brief guide

1 Ver.mob Brief guide 1 Ver.mob 14.02.2017 Brief guide 2 Contents Introduction... 3 Main features... 3 Hardware and software requirements... 3 The installation of the program... 3 Description of the main Windows of the program...

More information

ENGR 1000, Introduction to Engineering Design

ENGR 1000, Introduction to Engineering Design Unit 2: Mechatronics ENGR 1000, Introduction to Engineering Design Lesson 2.3: Controlling Independent Systems Hardware: 12 VDC power supply Several lengths of wire NI-USB 6008 Device with USB cable Digital

More information

Instruction Manual for the & Electronic Bingo Blower

Instruction Manual for the & Electronic Bingo Blower Instruction Manual for the 17212 & 17214 Electronic Bingo Blower The directions in this manual when referring to the 17212 are referring to software version 2.83 (you can find what version your blower

More information

CHAPTER 4 OSCILLOSCOPES

CHAPTER 4 OSCILLOSCOPES CHAPTER 4 OSCILLOSCOPES 4.1 Introduction The cathode ray oscilloscope generally referred to as the oscilloscope, is probably the most versatile electrical measuring instrument available. Some of electrical

More information

LOOK AT THE NETWORK OF METAL STRIPS ON THE BACKSIDE OF THE PROTOTYPING BOARD

LOOK AT THE NETWORK OF METAL STRIPS ON THE BACKSIDE OF THE PROTOTYPING BOARD Circuit Prototyping OBJECTIVES In this lab you will create a prototype of an electronic speed sensor that you will use to measure the speed of the roller coaster ball on your roller coaster. The lab has

More information

Lab experience 1: Introduction to LabView

Lab experience 1: Introduction to LabView Lab experience 1: Introduction to LabView LabView is software for the real-time acquisition, processing and visualization of measured data. A LabView program is called a Virtual Instrument (VI) because

More information

imso-104 Manual Revised July 19, 2012

imso-104 Manual Revised July 19, 2012 imso-104 Manual Section 1 Getting Started SAFETY 1.10 Quickstart Guide 1.20 SAFETY 1.30 Compatibility 1.31 Hardware 1.32 Software Section 2 How it works 2.10 Menus 2.20 Analog Channel 2.21 On / Off 2.22

More information

Introduction To LabVIEW and the DSP Board

Introduction To LabVIEW and the DSP Board EE-289, DIGITAL SIGNAL PROCESSING LAB November 2005 Introduction To LabVIEW and the DSP Board 1 Overview The purpose of this lab is to familiarize you with the DSP development system by looking at sampling,

More information

EAN-Performance and Latency

EAN-Performance and Latency EAN-Performance and Latency PN: EAN-Performance-and-Latency 6/4/2018 SightLine Applications, Inc. Contact: Web: sightlineapplications.com Sales: sales@sightlineapplications.com Support: support@sightlineapplications.com

More information

AC334A. VGA-Video Ultimate BLACK BOX Remote Control. Back Panel View. Side View MOUSE DC IN BLACK BOX ZOOM/FREEZE POWER

AC334A. VGA-Video Ultimate BLACK BOX Remote Control. Back Panel View. Side View MOUSE DC IN BLACK BOX ZOOM/FREEZE POWER AC334A BLACK BOX 724-746-5500 VGA-Video Ultimate BLACK BOX 724-746-5500 Zoom Position PAL ZOOM/FREEZE POWER FREEZE ZOOM NTSC/PAL SIZE RESET POWER Size Power Remote Control DC IN MOUSE MIC IN AUDIO OUT

More information

CATHODE-RAY OSCILLOSCOPE (CRO)

CATHODE-RAY OSCILLOSCOPE (CRO) CATHODE-RAY OSCILLOSCOPE (CRO) I N T R O D U C T I O N : The cathode-ray oscilloscope (CRO) is a multipurpose display instrument used for the observation, measurement, and analysis of waveforms by plotting

More information

LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution. A. Plotting a GM Plateau. This lab will have two sections, A and B.

LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution. A. Plotting a GM Plateau. This lab will have two sections, A and B. LAB 1: Plotting a GM Plateau and Introduction to Statistical Distribution This lab will have two sections, A and B. Students are supposed to write separate lab reports on section A and B, and submit the

More information

Topic: Instructional David G. Thomas December 23, 2015

Topic: Instructional David G. Thomas December 23, 2015 Procedure to Setup a 3ɸ Linear Motor This is a guide to configure a 3ɸ linear motor using either analog or digital encoder feedback with an Elmo Gold Line drive. Topic: Instructional David G. Thomas December

More information

Table of Contents Introduction

Table of Contents Introduction Page 1/9 Waveforms 2015 tutorial 3-Jan-18 Table of Contents Introduction Introduction to DAD/NAD and Waveforms 2015... 2 Digital Functions Static I/O... 2 LEDs... 2 Buttons... 2 Switches... 2 Pattern Generator...

More information

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier)

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier) Skip directly to the section that covers your version of Windows (XP and earlier, Vista or Windows 7) Quick Start for TrueRTA (v3.5) on Windows XP (and earlier) Here are step-by-step instructions to get

More information

There are many ham radio related activities

There are many ham radio related activities Build a Homebrew Radio Telescope Explore the basics of radio astronomy with this easy to construct telescope. Mark Spencer, WA8SME There are many ham radio related activities that provide a rich opportunity

More information

Standard Operating Procedure of nanoir2-s

Standard Operating Procedure of nanoir2-s Standard Operating Procedure of nanoir2-s The Anasys nanoir2 system is the AFM-based nanoscale infrared (IR) spectrometer, which has a patented technique based on photothermal induced resonance (PTIR),

More information

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes

Welch Allyn CardioPerfect Workstation Tango+ Interface Notes Welch Allyn CardioPerfect Workstation Tango+ Interface Notes To setup Tango+ with the CardioPerfect stress system, simply follow the directions below. 1. Verify Correct RS-232 and ECG Trigger Cables RS-232

More information

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. Hello, welcome to Analog Arts spectrum analyzer tutorial. Please feel free to download the Demo application software from analogarts.com to help you follow this seminar. For this presentation, we use a

More information

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL DATA ACQUISITION SYSTEM V.15.4 INSTRUCTION MANUAL Timberline Instruments, LLC 1880 S. Flatiron Ct., Unit I Boulder, Colorado 80301 Ph: (303) 440-8779 Fx:

More information

AC335A. VGA-Video Ultimate Plus BLACK BOX Back Panel View. Remote Control. Side View MOUSE DC IN OVERLAY

AC335A. VGA-Video Ultimate Plus BLACK BOX Back Panel View. Remote Control. Side View MOUSE DC IN OVERLAY AC335A BLACK BOX 724-746-5500 VGA-Video Ultimate Plus Position OVERLAY MIX POWER FREEZE ZOOM NTSC/PAL SIZE GENLOCK POWER DC IN MOUSE MIC IN AUDIO OUT VGA IN/OUT (MAC) Remote Control Back Panel View RGB

More information

SC24 Magnetic Field Cancelling System

SC24 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200

More information

9070 Smart Vibration Meter Instruction Manual

9070 Smart Vibration Meter Instruction Manual 9070 Smart Vibration Meter Instruction Manual Overall machine and bearing conditions: vibration values are displayed with color coded alarm levels for ISO values and Bearing Damage (BDU). Easy vibration

More information

Log-detector. Sweeper setup using oscilloscope as XY display

Log-detector. Sweeper setup using oscilloscope as XY display 2002/9/4 Version 1.2 XYdisp user manual. 1. Introduction. The XYdisp program is a tool for using an old DOS PC or laptop as XY display to show response curves measured by a sweeper log-detector combination.

More information

Activity P42: Sound Waves (Power Output, Sound Sensor)

Activity P42: Sound Waves (Power Output, Sound Sensor) Activity P42: Sound Waves (Power Output, Sound Sensor) Concept DataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win) Waves P42 Sound.DS P32 Sound Waves P32_SOUN.SWS Equipment Needed Qty Equipment Needed

More information

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1. MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Rev. 1.01 Page i Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice

More information

EVD-L04/100A1-960, EVD-L08/200A1-960 and. EVD-L16/400A1-960 DVRs. Quick Operation Guide

EVD-L04/100A1-960, EVD-L08/200A1-960 and. EVD-L16/400A1-960 DVRs. Quick Operation Guide EVD-L04/100A1-960, EVD-L08/200A1-960 and EVD-L16/400A1-960 DVRs Quick Operation Guide Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer.

More information

SC24 Magnetic Field Cancelling System

SC24 Magnetic Field Cancelling System SPICER CONSULTING SYSTEM SC24 SC24 Magnetic Field Cancelling System Makes the ambient magnetic field OK for the electron microscope Adapts to field changes within 100 µs Touch screen intelligent user interface

More information

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

Cover Page for Lab Report Group Portion. Boundary Layer Measurements Cover Page for Lab Report Group Portion Boundary Layer Measurements Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 23 February 2017 Name 1: Name 2: Name 3: [Name 4: ] Date:

More information

P-2 Installing the monitor (continued) Carry out as necessary

P-2 Installing the monitor (continued) Carry out as necessary P-2 Installing the monitor (continued) Carry out as necessary Using the monitor without the bezel MDT552S satisfies the UL requirements as long as it is used with the bezel attached. When using the monitor

More information

Scan Converter Quick Installation Guide

Scan Converter Quick Installation Guide Scan Converter Quick Installation Guide Software Note: No software is required to use your scan converter. Please complete the hardware installation and system setup before you determine the need to the

More information

MAIN PCA TEST PROCEDURE DOCUMENT NUMBER:

MAIN PCA TEST PROCEDURE DOCUMENT NUMBER: TEST PROCEDURE DOCUMENT NUMBER: -20 Signature Date Author J. Hoo 10-7-96 CHK J. Hoo 10-7-96 CHK - - Approved J. Hoo 10-7-96 Huntron Instruments, Inc. 1996 All rights reserved. This document may not be

More information

Getting started with

Getting started with Getting started with Electricity consumption monitoring single phase for homes and some smaller light commercial premises OVERVIEW: The OWL Intuition-e electricity monitoring system comprises of three

More information

ASE 369 K Measurements and Instrumentation. LAB #9: Impulse-Force Hammer; Vibration of Beams

ASE 369 K Measurements and Instrumentation. LAB #9: Impulse-Force Hammer; Vibration of Beams ASE 369 K Measurements and Instrumentation LAB #9: Impulse-Force Hammer; Vibration of Beams Equipment: Dell Optiplex computer with National Instruments PCI-MIO-16E-4 data-acquisition board and the Virtual

More information

Quality products from a single source

Quality products from a single source Velocity sensors Quality products from a single source For more than 50 years Brüel & Kjær Vibro has been a leading manufacturer of vibration measuring instruments and machine condition monitoring systems.

More information

Micro-Machined Silicon Transducers

Micro-Machined Silicon Transducers Micro-Machined Silicon Transducers wet/wet differential Pressure Models mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar PXM409 Differential Series Standard

More information

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 OBJECTIVE To become familiar with state-of-the-art digital data acquisition hardware and software. To explore common data acquisition

More information

PCASP-X2 Module Manual

PCASP-X2 Module Manual Particle Analysis and Display System (PADS): PCASP-X2 Module Manual DOC-0295 A; PADS 3.5 PCASP-X2 Module 3.5.0 2545 Central Avenue Boulder, CO 80301-5727 USA C O P Y R I G H T 2 0 1 1 D R O P L E T M E

More information

Product Data Sheet 4656 EZ

Product Data Sheet 4656 EZ The engineer's choice 4656 EZ INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

COLOR TFT LCD MONITOR. Manual

COLOR TFT LCD MONITOR. Manual COLOR TFT LCD MONITOR Manual Safety defended: Properly maintains your system to be possible to guarantee its service life and to reduce the damage risk. It should avoid the damp and exceeding temperature

More information

Getting started with

Getting started with PART NO. CMA11 3 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption & Solar PV generation monitoring single phase, for homes fitted

More information

AX system. Door stations Control Units & Stations CCTV - Telephony AX system CATA-CHAP7masterUK.indd 93 19/12/ :30

AX system. Door stations Control Units & Stations CCTV - Telephony AX system CATA-CHAP7masterUK.indd 93 19/12/ :30 Door stations... 95 Control Units & Stations... 96 CCTV - Telephony... 100 93 12132-CATA-CHAP7masterUK.indd 93 19/12/2017 12:30 120 1 8 INTERCOM ADVANTAGES: very affordable price flexible installation

More information

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151 Rectangular, aluminium / plastic Versatile mounting possibilities LED indicates measuring range Immune to electromagnetic interferences Extremely short blind zones 12 bit resolution 4-wire, 15 30 VDC Analog

More information

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded

More information

Graphing Your Motion

Graphing Your Motion Name Date Graphing Your Motion Experiment 33 Graphs made using a Motion Detector can be used to study motion. In this experiment, you will use a Motion Detector to make graphs of your own motion. OBJECTIVES

More information

Virtual Vibration Analyzer

Virtual Vibration Analyzer Virtual Vibration Analyzer Vibration/industrial systems LabVIEW DAQ by Ricardo Jaramillo, Manager, Ricardo Jaramillo y Cía; Daniel Jaramillo, Engineering Assistant, Ricardo Jaramillo y Cía The Challenge:

More information

Wall Ball Setup / Calibration

Wall Ball Setup / Calibration Wall Ball Setup / Calibration Wall projection game 1 Table of contents Wall Projection Ceiling Mounted Calibration Select sensor and display Masking the projection area Adjusting the sliders What s happening?

More information

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment Integrated Component Options Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment PRELIMINARY INFORMATION SquareGENpro is the latest and most versatile of the frequency

More information

Interactive Satellite Terminal Installation / Validation Manual

Interactive Satellite Terminal Installation / Validation Manual Installation / Validation Manual Version October 5, 2016 Index INTERACTIVE SATELLITE TERMINAL 1. FCC COMPLIANCE... 3 2. TECHNICAL FEATURES...4 3. GENERAL DESCRIPTION...5 4. ELEMENTS CONTAINED IN THE TERMINAL...6

More information

Using different reference quantities in ArtemiS SUITE

Using different reference quantities in ArtemiS SUITE 06/17 in ArtemiS SUITE ArtemiS SUITE allows you to perform sound analyses versus a number of different reference quantities. Many analyses are calculated and displayed versus time, such as Level vs. Time,

More information

STB Front Panel User s Guide

STB Front Panel User s Guide S ET-TOP BOX FRONT PANEL USER S GUIDE 1. Introduction The Set-Top Box (STB) Front Panel has the following demonstration capabilities: Pressing 1 of the 8 capacitive sensing pads lights up that pad s corresponding

More information

4 MHz Lock-In Amplifier

4 MHz Lock-In Amplifier 4 MHz Lock-In Amplifier SR865A 4 MHz dual phase lock-in amplifier SR865A 4 MHz Lock-In Amplifier 1 mhz to 4 MHz frequency range Low-noise current and voltage inputs Touchscreen data display - large numeric

More information

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

NanoGiant Oscilloscope/Function-Generator Program. Getting Started Getting Started Page 1 of 17 NanoGiant Oscilloscope/Function-Generator Program Getting Started This NanoGiant Oscilloscope program gives you a small impression of the capabilities of the NanoGiant multi-purpose

More information

EAGLE RE-1 CONTROLLER For Use On MotoSAT HD Mounts

EAGLE RE-1 CONTROLLER For Use On MotoSAT HD Mounts EAGLE RE-1 CONTROLLER For Use On MotoSAT HD Mounts Supported Systems HD SL5 DirecTV HD DP3 Dish Network HD SC2 SHAW HD DP3 BELL TV EXECUTIVE DirecTV 101 Dish Network 119 MSC-60 SHAW MD-500 Dish Network

More information

Magnetic Force Microscope (MFM)

Magnetic Force Microscope (MFM) Magnetic Force Microscope (MFM) [Digital Instruments NanoScopeIII] magnetic and topographic resolution ~20 nm [at least several hours/sample (1 cm 2 polished single grains, thin sections, or thin films)]

More information

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar Micro-Machined Silicon Transducers wet/dry differential mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar PXM409 Differential Series U 5-Point NIST Traceable

More information

013-RD

013-RD Engineering Note Topic: Product Affected: JAZ-PX Lamp Module Jaz Date Issued: 08/27/2010 Description The Jaz PX lamp is a pulsed, short arc xenon lamp for UV-VIS applications such as absorbance, bioreflectance,

More information

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it! Laser Beam Analyser Laser Diagnos c System If you can measure it, you can control it! Introduc on to Laser Beam Analysis In industrial -, medical - and laboratory applications using CO 2 and YAG lasers,

More information

LeRIBSS MTC MANUAL. Issue #1. March, MTC Control Unit Definitions, Information and Specifications. MTC Control Unit Electronic Schematics

LeRIBSS MTC MANUAL. Issue #1. March, MTC Control Unit Definitions, Information and Specifications. MTC Control Unit Electronic Schematics LeRIBSS MTC MANUAL Issue #1 March, 2008 Contents: MTC Control Unit MTC Control Unit Definitions, Information and Specifications Programming the MTC Control Unit Program Parameters Initial Setup Measuring

More information

User Manual VM700T Video Measurement Set Option 30 Component Measurements

User Manual VM700T Video Measurement Set Option 30 Component Measurements User Manual VM700T Video Measurement Set Option 30 Component Measurements 070-9654-01 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - FAX 781.665.0780 - TestEquipmentDepot.com

More information

IMPORTANT SAFETY INSTRUCTIONS Please read User Guide before using this product. Please keep User Guide for future reference. Please read the cautions

IMPORTANT SAFETY INSTRUCTIONS Please read User Guide before using this product. Please keep User Guide for future reference. Please read the cautions User Guide IMPORTANT SAFETY INSTRUCTIONS Please read User Guide before using this product. Please keep User Guide for future reference. Please read the cautions to prevent possible danger and loss of property.

More information

Vibration-Free Pulse Tube Cryocooler Systems for Gravitational Wave Detectors II II

Vibration-Free Pulse Tube Cryocooler Systems for Gravitational Wave Detectors II II Vibration-Free Pulse Tube Cryocooler Systems for Gravitational Wave Detectors II II --Cooling Performance and Vibration -- Rui Li A, Y. Ikushima A, T. Koyama A, T. Tomaru B, T. Suzuki B, T. Haruyama B,T.

More information

Scanning For Photonics Applications

Scanning For Photonics Applications Scanning For Photonics Applications 1 - Introduction The npoint LC.400 series of controllers have several internal functions for use with raster scanning. A traditional raster scan can be generated via

More information

PS User Guide Series Seismic-Data Display

PS User Guide Series Seismic-Data Display PS User Guide Series 2015 Seismic-Data Display Prepared By Choon B. Park, Ph.D. January 2015 Table of Contents Page 1. File 2 2. Data 2 2.1 Resample 3 3. Edit 4 3.1 Export Data 4 3.2 Cut/Append Records

More information

SRV02-Series. Ball & Beam. User Manual

SRV02-Series. Ball & Beam. User Manual SRV02-Series Ball & Beam User Manual Table of Contents 1. Description...3 1.1 Modular Options...4 2. System Nomenclature and Components...5 3. System Setup and Assembly...6 3.1 Typical Connections for

More information

Linrad On-Screen Controls K1JT

Linrad On-Screen Controls K1JT Linrad On-Screen Controls K1JT Main (Startup) Menu A = Weak signal CW B = Normal CW C = Meteor scatter CW D = SSB E = FM F = AM G = QRSS CW H = TX test I = Soundcard test mode J = Analog hardware tune

More information

CHEMISTRY SEMESTER ONE

CHEMISTRY SEMESTER ONE APPENDIX A USING THE SPECTROMETER FOR AN EMISSION SPECTROSCOPY NANSLO REMOTE WEB-BASED SCIENCE LAB ACTIVITY The following provides information how to use the spectrometer controls for the Emission Spectroscopy

More information

Snail Fence InteleCell Deployment Guide

Snail Fence InteleCell Deployment Guide Snail Fence InteleCell Deployment Guide Preparation 1. Prepare deployment trip by making sure you have the following materials and tools when you fly up to the site: InteleCell NEMA Enclsoure (grey plastic

More information

Genelec 2029B Digital Monitoring System. Operating Manual

Genelec 2029B Digital Monitoring System. Operating Manual Genelec 2029B Digital Monitoring System Operating Manual 2029B Digital Monitoring System 1. General description Genelec 2029B Digital Monitoring System has a 96 khz/24 bit digital audio interface allowing

More information