Operating instructions - High Performance LED Timer / / /

Size: px
Start display at page:

Download "Operating instructions - High Performance LED Timer / / /"

Transcription

1 Operating instructions - High Performance LED Timer / / / Your tico 742 timer is a powerful instrument which can be field configured to fit a wide variety of applications. The secondary setpoint can be used for a second time output, combining the function of two timers in a single package, or as a batch counter to track the amount of completed cycles. 1 ms resolution with transistor outputs make this unit well suited for high speed processes. Inside this manual you will find complete information on the Control mode, which deals with viewing and changing the available setpoints, and Program Mode which is used to configure the basic operation of the timer, as well as set a variety of other useful features. Also found in this manual are detailed timing diagrams and descriptions of the available operating functions to aid you in determining how to properly configure the unit to solve your application. Additionally included are key product specifications and ordering information should you require additional units or accessories. Please read the safety information carefully prior to the installation of the unit! Features 17 Different, field programmable, modes of operation Batch Count function with timed or latched output Dual setpoints in many modes Simple button per digit interface Timing resolution down to 1 ms Programmable security levels prevent unauthorized setpoint or program changes High Visibility LED display of both time value and setpoint Available with relay or solid state outputs IEC IP65 rated front panel Repeatability of 0.01% Inhibit input halts timing without resetting the cycle Rev tico 742 page 1/16

2 Safety and warning hints This symbol inidcates passages in the text where you have to pay special attention so as to guarantee correct use and exclude any risk. This device is made and tested according to the valid standards of technics and has left the factory in a perfect safety state. To keep this state and secure operation without danger, the user has to observe the saftety and warning hints, contained in this operation manual. There is no galvanic separation of the inputs from the power supply. The device must be protected against accidential contact if it is not supplied from a SELV source (see EN ). Assembling and mounting of electrical divices are restricted to be done by skilled electricians! Skilled electrician is, who can judge the tasks deputed to him and foresee possible dangers, due to his special education, knowledge and experience and consciousness of the pertinent standards. Mount devices are only allowed to be operated when mounted. Finger protection at connection part of mount devices is to be secured when mounting! While mounting the device, it must be secured that the requirements, which are asked for the device in the pertaining standards for safety, are not affected in a negative way, so reducing the safety of this mount device. Mounting and assembling of device needs observation of the specifications of the local Energy Suppliers. Before switching on, make sure that the power and control voltages are not exceeding the values in accordance with the technical data. If it is to be assumed that operation without danger is not further possible, the device must be put out of operation and secured from unintentional operation! It must be assumed that an operation without danger is not further possible, if the device shows damage, if the device stops functioning, after a longer stocking period under unfavourable conditions, after heavy strain during transportation. If by a failure or a malfunction of the device, endangering of men or animals or damaging of facilities are possible, this must be avoided by additional safety measures (end switches, protection devices and etc.). Before opening any cover, the device must be switched voltagefree. Hengstler Counters are intended for industrial applications. The mounting environment and nearby cabling have an important influence on the EMC (noise radiation and noise immunity) of the counter. When putting into operation, the EMC of the whole installation (unit) has to be secured. In particular, the relay outputs are to be protected from high noise radiation by suitable wiring. The range of applications for those products are industrial processes and controls, where the overvoltages applied to the product at the connection terminals are limited to values of the overvoltage category II. page 2/16 tico Rev

3 Installation tico E 48 mm P 8 mm 81 mm 66 mm,,, mm,,, Einbauausschnitt Panel Cutout To wire the unit, an 11-pin socket is required (refer to Ordering Information on last page). The unit can either be DIN rail mounted or panel mounted using the supplied mounting bracket. For panel mounting, place the unit in the cutout, then slide the bracket forward over the rear of the unit so that the tabs catch in the grooves on the housing and the bracket is as far forward as possible. Tighten the panel mount screws until there is a snug fit against the panel. Do not overtighten. Wiring Inhibit Inhibit Out1 (Timed) Out 2 (Timed or Batch) Out 1 Out Power (-) (+) Power (-) (+) AC Power WARNING: Do not connect a coil in parallel with the signal, as pictured at left. Such a connection will cause the signal to be continuously active. This situation also applies to the and Inhibit inputs AC Power Rev tico 742 page 3/16

4 Technical Data / 202/ 251/ 252 Power Supply Display Time Ranges Resolution input/ input Signal times Relay ( XX) Transistor Outputs ( /252 Life Mounting Rating Temperature General Accessories /251: VAC 50/60 Hz; +10% -15%; < 10 VA; typ. 4 VA /252: 24 V AC/DC; +10%,-15%; <200 ma; typ. 100 ma LED display, 2 lines, 4 digits each line, indicators for input signals, output statur and time ranges 5 time ranges can be programmed: Hours, Minutes, Seconds, hh:mm, mm:ss; up to 9999 hours Settable for XXXX to X.XXX for Hours, Minutes and Seconds, resolution down to 1ms Dry contact or NPN; Contact requirements <1kOhm; NPN requirements: VDE0 = 20 V (min), ICB0 = 0.5 A (max) activation: > 20 ms; drop out > 80 ms activation: > 20 ms; drop out > 20 ms Power interruption > 800 ms 2x Changeover contact 5 A, 120/240 VAC or 30 VDC; Reaction time approx. 15 ms NPN Open Collector; 30 VDC; 30 ma max.: opto isolated electrical 100,000 cycles, mechanical 10 million cycles Front panel mounting with mounting bracket or DIN rail mounting with socket, panel thicknes max. 10 mm Front Panel IP 65 Operation: 0 C to + 55 C Storage: -40 C to + 90 C DIN EN part 1; Protection according to class II; Contamination level 2; Overvoltage category II 11 pin socket Operating I/O Status Indicators Illuminates to display when an input or output is active: IN for the start input, O1 and O2 for the timed outputs. Preset 2 Indicator Illuminates to indicate that Preset 2 is being shown on the lower display. Numeric Keys Each of the number keys is used to increment the value of the corresponding digit of the preset or parameter value Primary Display In Control Mode: Displays the current time value associated with the displayed preset or the batch value (if configured). In Program Mode: Display the Parameter Description. Time Range Indicator Illuminates to show the time base: H for hours, M for minutes, S for seconds. Multiple indicators will be illuminated when the time base is Hours: Minues or Minutes:Seconds. During timing operation the illuminated LED will flash. Batch Indicator Illuminates to indicate that the Batch Count Value and Batch Preset are being displayed. Set Value In Control Mode: Displays the settable value used to trigger the timed output(s) and the batch count (if configured). In Program Mode: Displays the curent selection for the chosen parameter. Edit Key In Control Mode: With P key, resets the display value. In Program Mode: Scrolls between the applicable choices for the currently displayed parameter. Program Key In Control Mode: Depressing the key will scroll the display among the preset and batch displays. Holding the key down for 3 seconds will shift the unit into Program Mode. With the E key, resets the displayed value. In Program Mode: Depressing the key will scroll the display from one parameter to the next. Holding the key down for 3 seconds will shift the unit to Control Mode. page 4/16 tico Rev

5 Control Mode - How to select a display and change preset values Preset 1 Display Top display: Time Value for Operation Bottom display: Preset 1 Annunciators: Time Range Pressing the numeric keys will cause the corresponding digit to increment by a value of one (i.e. the 1 key increments the rightmost digit, the 2 key the 2nd digit from the right, etc.). It is not necessary to press any other keys to enter the change, the new set point value will become effective immediately. Please note that based on the Operating Mode and Output 2 selection, Preset 2 may not be an available display. Preset 2 Display Top display: Time Value for Operation Bottom display: Preset 2 Annunciators: Time Range & Changes are made in the same manner as for Preset 1 (detailled above). Please note that based on the Operating Mode and Output 2 selection, Batch may not be an available display. Batch Display Top display: Batch Count Value Bottom display: Batch Count Preset Annunciators: Batch Changes are made in the same manner as for Preset 1 (detailled above) Rev tico 742 page 5/16

6 Program Mode Func OndL The programming mode is entered or left by pressing the P-key for approximately 3 seconds. Press P to move one parameter to the next. Press E to scroll through the applicable choices for the currently displayed parameter Timing is interrupted while the unit is in program mode Changes become valid after returnal to control mode Operating Function: Determines how output 1 will operate in relation to the Preset 1. Choices are: On Delay (OndL), Off Delay (OFdL), Interval 1 (int1: must be sustained) Interval 2 (int2: Edge triggered; need not be sustained) On/Off Delay (OnOF), Delay/Interval (dint), Accumulative (ACC) A complete explanation, with timing diagrams, of each function can be found on page 9. out2 0 AbS Note: The following parameter will not appear if Operating Function is set to Off Delay, Delay/ Interval or On/Off Delay. In these instances Output 2 automatically defaults to Batch Count. Output 2 Operation: Determines the functionality of the 2nd output. Choices are: Preset 2 (): The unit will function as a dual setpoint timer, with output 2 linked to Preset 2. Batch Count (bc): Output 2 will be activated after a preset amount of Operations is completed. The preset value is input in the Batch count screen in Control Mode. Note: The following parameter will only appear if Output 2 is set to Preset 2. Preset 2 Operation: Determines how Preset 2 will operate in relation to Preset 1. The available choices vary based upon the selected Operating Function : For On-Delay and Accumulative: Absolute (AbS): Preset 2 is input as an absolute value, and the unit operates like two independent On-Delay timers. Prewarn (PrE): Preset 2 is set as a value relative to Preset 1. The input value for is equal to the amount of time that Output 2 will activate prior to Output1. Ex: If = 20 seconds, and equals 5, then output 2 will activate 15 seconds (20-5) after the timing cycle is initiated. For Interval 1 and Interval 2: Begin Together (bt): Preset 2 is set as an independent time interval which will begin timing and activate Output 2 upon initiation of the start signal. End Together (Et): Preset 2 is set as a value relative to Preset 1. The timing sequence for will initiate at the appropriate time so that the timing sequences for and will end simultaneously and Output 1 and Output 2 will deactivate together. Sequential (SE): Preset 2 is set as an inependent time interval which will begin its timing sequence upon completion of the interval. bct 0000 Note: The following parameter will only appear if Output 2 is set to Batch Count. Batch Count Output: Sets the duration of Output 2, within a range from 1 second to 9999 seconds. A setting of 0000 will latch the output until a reset signal is received. page 6/16 tico Rev

7 trn 1 Time Range 1: Sets the unit of measure for the time values that will be used for Preset 1. The choices will not appear on the bottom display, but will be signified with the annunciator lights. Choices are: Seconds, Minutes, Hours, Minutes:Seconds, Hours:Minutes. dec 1 Note: The following parameter will not appear if Minutes:Seconds or Hours:Minutes is chosen for Time Range 1. Decimal Position for Time Range 1: Determines the resolution of the selected time range. Settable from 0000 to trn 2 Note: The following parameter will only appear for those configurations that provide a Preset 2 display. Time Range 2: Sets the unit of measure for the time values that will be used for Preset 2. The choices will not appear on the bottom display, but will be signified with the annunciator lights. Choices are: Seconds, Minutes, Hours, Minutes:Seconds, Hours:Minutes. dec 2 Note: The following parameter willnot appear if Minutes:Seconds or Hours:Minutes is chosen for Time Range 2. Decimal Position for Time Range 2: Determines the resolution of the selected time range. Settable from 0000 to tdir up Timing Direction: Determines whether the time values for Preset 1 and 2 will increment from zero and change the state of the output at the set value (up) or decrement from the set value and change the state of the output at zero (dn). PrSt On FrSt 0n Power Enable: After a loss of power, the unit can be either reset upon reapplication of power (0n) or continue from the point of power interruption (OFF). Front Panel : When active (On), the timing operation can be reset in Control Mode by simultaneously pressing the E and P keys. If inactive (OFF), the timing operation can only be reset through the remote input. SLuL 0 Security Level: 4 different levels of security are available: 0 = Full Access 1 = SP Locked Out 2 = Access to Program Mode only by holding the P key for 10 seconds. 3 = SP Locked Out and access to Program Mode only by holding the P Key for 10 seconds Rev tico 742 page 7/16

8 Programming Overview * If Delay/ Interval or On/ Off are selected as the Operating Function, Out2 is automatically set to Batch. However, the setting is still available, and the second time range is available ** For the Interval 1 & Interval 2 modes, a second time range will not appear if the Preset 2 operation is set to End Together. This is also true for the On Delay and Accumulative Modes if Prewarn is the selection for Preset 2 Operation. page 8/16 tico Rev

9 Timing Diagrams On Delay - Absolute On Delay - Prewarn Preset 1 On leading edge of On completion of Timing start signal Preset 2 On leading edge of On completion of Timing start signal Output 1 Upon completion of On Output 2 Upon completion of On An Inhibit input will halt timing functions, bit leave the outputs in their current state. If the start input is applied during, a new timing cycle will begin on the trailing edge of the reset signal. Preset 1 On leading edge of On completion of Timing start signal Preset 2 Prior to completion of by On completion of Timing the amount of time set in Output 1 Upon completion of On Output 2 Prior to completion of by On the amount of time set in must be set to a value greater than. An Inhibit input will halt all timing functions, but leave the outputs in their current state. If the start input is applied during, a new timing cycle will begin on the trailing edge of the signal. On Delay w/ Batch On Delay/ Interval w/ Batch / Batch 1 2 / Batch 1 2 BT Preset 1 On leading edge of On completion of Timing start signal Batch Accumulates on activa- On, only after the Count tion of Output 1 Batch Count Preset is reached Output 1 On completion of On Output 2 When the Batch Count value On completion of Batch equals the Batch Preset Output time An Inhibit input will halt all timing functions, but leave the outputs in their current state. If the start input is applied during, a new timing cycle will begin on the trailing edge of the signal. The Remote will only reset the Batch Count value after the Batch Preset has been reached, however, the Batch Count value can be reset at anytime via Front Panel. Preset 1 On leading edge of On completion of Timing start signal Preset 2 On activation of Output 1 On completion of Timing Batch Accumulates on falling On, only after the Batch Count edge of Output 1 Count Preset is reached Output 1 On completion of On completion of or Output 2 When the Batch Count value On completion of Batch equals the Batch Preset Output time An Inhibit input will halt all timing functions, but leave the output in their current state. A reset singal is not reuired to start a new cycle. The Remote will only reset the Batch Count value after the Batch Preset has been reached, however, the Batch Count value can be reset at anytime via Front Panel Rev tico 742 page 9/16

10 Interval 1 - Begin Together Interval 2 - Begin Together Preset 1 On leading edge of On completion of, deas- Timing start signal sertion of the Signal Preset 2 On leading edge of On completion of, deas- Timing start signal sertion of the Signal Output 1 On leading edge of On completion of, deasstart signal sertion of the Signal Output 2 On leading edge of On completion of, deasstart signal sertion of the Signal An Inhibit input will halt all timing functions, but leave the outputs in their current state. Preset 1 On leading edge of On completion of Timing start signal Preset 2 On leading edge of On completion of Timing start signal Output 1 On leading edge of On completion of start signal Output 2 In leading edge of On completion of start signal Operates the same as the Interval 1 - Begin Together Mode, except the start input does not have to be sustained to continue operation. An Inhibit input will halt all timing functions, but leave the outputs in their current state. Interval 1 - End Together Interval 2 - End Together Preset 1 On leading edge of On completion of, deas- Timing start signal sertion of the Signal Preset Prior to completion of On completion of, deas- Timing by the amount of time sertion of the Signal in Output 1 On leading edge of start On completion of, deassignal sertion of the Signal Output 2 Prior to completion of by On completion of, deasthe amount of time set in sertion of the Signal An Inhibit input will halt all timing functions, but leave the outputs in their current state. Preset 1 On leading edge of On completion of Timing start signal Preset 2 Prior to completion of On completion of Timing by the amount of time set in Output 1 On leading edge of start On completion of signal Output 2 Prior to completion of On completion of by the amount of time set in Operates the same as the Interval 1 - End Together mode, except the start input does not have to be sustain to continue operation. An Inhibit input will halt all timing functions, but leave the outputs in their current state. page 10/16 tico Rev

11 Interval 1 - Sequential Interval 2 - Sequential Preset 1 On leading edge of On completion of, deas- Timing start signal sertion of the Signal Preset 2 On completion of On completion of, deas- Timing sertion of the Signal Output 1 On leading edge of On completion of, deasstart signal sertion of the Signal Output 2 On completion of On completion of, deassertion of the Signal An Inhibit input will halt all timing functions, but leave the outputs in their current state. Preset 1 On leading edge of On completion of, Timing start signal Preset 2 On completion of On completion of, Timing Output 1 On leading edge of On completion of start signal Output 2 On completion of On completion of Operates the same as the Interval - Sequencial mode, except the start input does not have to be sustained to continue operation. An Inhibit input will halt all timing functions, but leave the outputs in their current state. Interval 1 - Batch Interval 2 - Batch / Batch BCT / Batch BCT Preset 1 On leading edge of On completion of, deas- Timing start signal sertion of the Signal Batch On trailing edge of On Count Output 1 Output 1 On leading edge of On completion of, deasstart signal sertion of the Signal Output 2 When the Batch Count On completion of the Value equals the Batch Batch Output Time or Preset It is not necessary to reset the timer to begin a new interval, however reset is required to set the batch count value back to 0. An Inhibit input will halt all timing functions, but leave the outputs in their current state. Preset 1 On leading edge of On completion of Timing start signal Batch On trailing edge of On Count Output 1 Output 1 On leading edge of On completion of start signal Output 2 When the Batch Count On completion of the Value equals the Batch Batch Count Time Preset Operates the same as the Interval - Sequencial mode, except the start input does not have to be sustained to continue operation. It is not necessary to reset the timer to begin a new interval, however reset is required to set the batch count value back to 0. An Inhibit input will halt all timing functions, but Rev tico 742 page 11/16

12 Off Delay - Batch Count On/Off Delay - Batch Count -T / Batch BCT / Batch 1 Preset 1 On trailing edge of On completion of Timing start signal Batch On trailing edge of On Count Output 1 Output 1 On leading edge of On completion of start signal Output 2 When the Batch Count On completion of the Value equals the Batch Batch Output Time or Preset It is not necessary to reset the timer to begin a new interval, however reset is required to set the batch count value back to 0. An Inhibit input will halt all timing functions, but leave the outputs in their current state. signals will be accepted while the Batch Count Output is active. Accumulative - Absolute (Time counter with 2 Presets) Preset 1 On change of state of On change of state of the Timing the start signal start signal or reset Preset 2 On change of state of On change of state of the Timing the start signal after start signal after is has elapsed active, Batch Accumulates on falling On expiration of the Batch Count edge of Output 1 Count Time Output 1 On completion of On completion of Output 2 When the Batch count On completion of Batch value equals the Batch Output time Preset Any transition of the start signal will effect the timing operation: During the timing cycle for a transition will cause to restart. A transition of the start signal after has completed will cause to begin. Any transition of the start signal prior to the completion of (and the deactivation of Output 1) will cause to restart. An Inhibit input will halt all timing functions, but leave the outputs in their current state. Accumulative - Prewarn (Time counter with Prewarn) t1 t2 t3 t4 t1 t2 t3 t1 + t2 + t3 = t1 + t2 + t3 = t1 + t2 + t3 + t4 = t2' + t3' = t2' t3' Preset 1 On leading edge of On completion of Timing each start signal Preset 2 On leading edge of On completion of Timing each start signal Output 1 On completion of On Output 2 On completion of On Accumulates the time while is active. When the Time total reaches the output OUT1 is activated. and are independent Presets. Preset 1 On leading edge of On completion of Timing start signal Preset 2 Prior to completion of On completion of or Timing by the amount of time set in Output 1 On completion of On Output 2 Prior to completion of On by the amount of time set in Accumulates the time while is active. When the Time total reaches the output OUT1 is activated. and are independent Presets. The resulting preset for OUT2 is -. page 12/16 tico Rev

13 Accumulative - Batch t1 t2 t1 t2 / Batch Preset 1 On leading edge of On completion of Timing start signal Batch On leading edge of On, only after the Count Output 1 Batch Count Preset is reached Output 1 On leading edge of On completion of start signal Output 2 When the Batch Count On, only after the Value equals the Batch Batch Count Preset is reached It is not necessary to reset the timer to begin a new interval, however reset is required to set the batch count value back to 0. An Inhibit input will halt all timing functions, but leave the outputs in their current state. signals will be accepted while the Batch Output is active. Order Information TICO 742 Multifunction, LED, VAC TICO 742 Multifunction, LED, 24 VACDC TICO 742 High Performance, Relay, VAC TICO 742 High Performance, Relay, 24 VAC DC TICO 742 High Performance, Transistor, VAC TICO 742 High Performance, Transistor, 24 VAC DC TICO 742 Repeat cycle, Relay, VAC TICO 742 Repeat cycle, Relay, 24 VAC DC TICO 742 Repeat cycle, Transistor, VAC TICO 742 Repeat cycle, Transistor, 24VACDC pin socket Hints To wire the unit an 11 pin socket is required. The unit can then either be DIN rail mounted, or panel mounted using the mounting bracket included in the package Rev tico 742 page 13/16

14 Notice page 14/16 tico Rev

15 Notice Rev tico 742 page 15/16

16 1997 HENGSTLER GmbH HENGSTLER GmbH claims the copyright for this documentation. This documentation may not changed, amended, or copied without prior written consent of HENGSTLER GmbH, and may not be used in contradiction to this companys rightful interests. Technical data subject to alterations. Hengstler GmbH Postfach D Aldingen/Germany House address: Uhlandstraße 49 D Aldingen Tel Fax Sales: Tel oder Technical Support: Tel info@hengstler.de Member of the U.S.A. DQS-zertifiziert nach DIN EN ISO 9001 Reg. Nr

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual

Veeder-Root brand Series C628 Dual Preset Counter (C628-8XXX) Technical Manual Introduction Your Veeder-Root brand C628 Dual Preset Counter is one model in a family of 1/8 DIN units which offers breakthrough display technology as well as easy-to-program single-line parameters. Designed

More information

Multifunction Digital Timer

Multifunction Digital Timer Multifunction Digital Timer 72 x72 mm Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01 Universal Flow Controller Model 261 / 261-EC-01 Instruction Manual Type ARS 261-EC 01 Art.-no: 82212264 Table of Contents 1. Safety Instructions 2. Product ID - Dimensions 3. Function Description 4. Installation

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

Preset counters, electronic

Preset counters, electronic The multifunction preset counters Codix 923 / 924 can be used universally. These preset pulse counters, tachometers or preset timers with up to 6 presets can solve a wide variety of control and monitoring

More information

DCP100 Digital Control Programmer Specifications

DCP100 Digital Control Programmer Specifications DCP100 Digital Control Programmer Specifications EN01-6028 October 1996 Overview The DCP100 is a microprocessor based 1 /4 DIN programmer/controller for process variable versus time control of temperature,

More information

Solid-State Digital Timer

Solid-State Digital Timer Solid-State Digital Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay,

More information

HS-509 VIBRATION TRIP MODULE

HS-509 VIBRATION TRIP MODULE HS-509 VIBRATION TRIP MODULE 1. Overview The HS-509 is a configurable trip amplifier capable of accepting a 4-20mA signal from a HS-420 sensor and providing two trip action relay outputs along with an

More information

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min Weekly Time Switch Easy Programming with Large LCD Display and Interactive Functions Programming for 24 hrs x 7 days using just five switches. Sixteen program steps available. Power supply freely selectable

More information

Gamma instabus. Technical product information

Gamma instabus. Technical product information Gamma instabus Technical product information Universal dimmer N 554D31, 4 x 300 VA / 1x 1000 VA, AC 230 V Universal dimmer N 554D31 Control of dimmable lamps, including LED without minimum load Output

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly

Preset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly The Codix 923/924 can be used universally. As a preset pulse counter, tachometer or preset timer with up to 6 presets it is able to solve a very wide range of control and monitoring tasks in every application.

More information

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper

More information

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load

More information

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4 UDC100 Universal Digital Controller 51-52-03-29 11/99 Page 1 of 4 Specification Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904 Operating Instructions 3.96.3 (ed. 5.97) Electronic Preset Counter Type Series 904 1. Description 6 digit preset counter, 2 presets, add./subtr. bright 2-line LCD display with symbols for activated outputs

More information

Single Axis Position Controller

Single Axis Position Controller SERIES P9511 Single Axis Position Controller Compact Construction Simple Go-to operation Integrated Relay Output Integrated Mains Power Supply ELEKTRO-TRADING sp. Z o.o. 44-109 Gliwice, ul. Mechaników

More information

Operating Instructions

Operating Instructions COUNTERS CONTROLLERS ENCODERS Operating Instructions Electronic Preselection Counter Two preselections NE 216 Contents Page 1 Safety indications... 2 2 Get to know your NE 216... 4 2.1 NE216 components...

More information

Process transmitter RMA422

Process transmitter RMA422 Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set

More information

Standard RS232 RS ma

Standard RS232 RS ma 1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision

More information

02/11/2015

02/11/2015 24 x 48 Totalizers CTR24 non-backlit model Part number 87622062 Display : 8-digit LCD, height 8 mm Powered by a lithium battery Counter inputs : solid state (4-30 VDC) or voltage (10 260 VAC) Reset on

More information

Standard signal metering in wall-mounting case

Standard signal metering in wall-mounting case User manual AKV-2VR4C Standard signal metering in wall-mounting case Technical features: Digit height: 20 mm Colour: red Range of display: -999 9999 Wall-mounting case: black, made of ABS-plastic Protection

More information

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at ACT 10 Digital Keypad Operating & Installation Instructions 18-00001 This manual is found at www.eaglesecuritysolutions.co.uk Installation Notes Always remember to factory default the controller before

More information

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance: AK-PVE4 Operating Instructions Measuring of norm signals in wall-type units 1 2 P Performance: Digit heights: 20 mm Colour: red Display range: -999 9999 Wall-type housing: light grey made of ABS-plastic

More information

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT Universal Control Unit UC-1-E User Manual General Information Universal Control Unit UC-1 Of Central Lubrication CC DC 24 V 5A / M 15 SL /MK 31 M Z 30 General Information Contents Universal Control Unit

More information

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Assembly. Front view. LEDs. Parametrization interface. Power Bus otation Speed Monitor Features Assembly 1-channel signal conditioner 2 V DC supply Input for 2- or -wire sensors Input frequency 10 mhz... 50 khz elay contact output Start-up override and restart inhibit

More information

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE 1 Description The is a programmable 3 relay logic module that may be used for multiple applications, including simple timing, door mounted sensor inhibiting and advanced relay sequencing. The contains

More information

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1. USER S GUIDE PROGRAMMABLE 3-RELAY LOGIC MODULE 1 Description The is a programmable 3 relay logic module that may be used for multiple applications, including simple timing, door mounted sensor inhibiting

More information

Dimming actuators GDA-4K KNX GDA-8K KNX

Dimming actuators GDA-4K KNX GDA-8K KNX Dimming actuators GDA-4K KNX GDA-8K KNX GDA-4K KNX 108394 GDA-8K KNX 108395 Updated: May-17 (Subject to changes) Page 1 of 67 Contents 1 FUNCTIONAL CHARACTERISTICS... 4 1.1 OPERATION... 5 2 TECHNICAL DATA...

More information

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650 M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de

More information

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

High Resolution Multicolor Contrast Scanner. Dimensioned drawing Specifications and description KRTM 20 High Resolution Multicolor Contrast Scanner Dimensioned drawing en 01-2011/06 50116669 12mm 20mm 50mm 12-30 V DC 50 / 25 khz We reserve the right to make changes

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

Luminaire installation box Surface-mounted box Ceiling installation box

Luminaire installation box Surface-mounted box Ceiling installation box -Smart PTM Ambient light sensor and motion detector for constant lighting control uminaire installation box Surface-mounted box Ceiling installation box Overview: -SMART PTM i is an ambient light sensor,

More information

Electronic Pulse Counter Combination device

Electronic Pulse Counter Combination device Electronic Pulse Counter Combination device measuring monitoring analysing Input: pulse counter, time meter Display: 6-digit LED Height of digits: 14/8 mm Operation with front-panel buttons Material: plastic

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

Hour Meters / Timers, electronic

Hour Meters / Timers, electronic Hour Meters / Timers, electronic LED Timers Codix 523 For use as a timer, hour meter or short-time meter Pulse width measurement (operating time) Time interval measurement (start/stop) DC 000000 0... 30V

More information

Electrical connection

Electrical connection Splice sensor Dimensioned drawing en 04-2014/06 50116166-01 4mm 12-30 V DC We reserve the right to make changes DS_IGSU14CSD_en_50116166_01.fm Reliable detection of splice on paper web or plastic web With

More information

SAUTER flexotron RDT405 Manual

SAUTER flexotron RDT405 Manual SAUTER flexotron 400 - RDT405 Manual P100012100 Table of contents DISCLAIMER The information in this manual has been carefully checked and is believed to be correct. Fr. Sauter AG however, makes no warranties

More information

Preset counters, electronic

Preset counters, electronic LCD preset counters Adding or subtracting (battery) 901 Type 901 is a simple battery powered preset pulse counter with 12... 250 V AC/DC count and reset input. The 6-digit, 2-line LCD display shows the

More information

FS340 and FS641. High Performance Low Cost Controller for Flying Shears and Saws

FS340 and FS641. High Performance Low Cost Controller for Flying Shears and Saws control motion interface motrona GmbH Zwischen den Wegen 32 78239 Rielasingen - Germany Tel. +49 (0)7731-9332-0 Fax +49 (0)7731-9332-30 info@motrona.com www.motrona.com FS340 and FS641 High Performance

More information

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630) Vorne Industries 87/719 Analog Input Module User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Introduction... 1.1 Accessing Wiring Connections

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

A meter which accumulates pulse counts. Also these counters do not outputs. Cub5 Counter

A meter which accumulates pulse counts. Also these counters do not outputs. Cub5 Counter COUNTERS Three Types of Counters Totalizing Counters A meter which accumulates pulse counts. Also these counters do not outputs. Cub5 Counter Two Counters and a Rate Indicator in ONE Package 8 Digit Display

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module Helvar Data is subject to change without notice. www.helvar.com i Contents Section Page Introduction 1 Installation 2 1. Attach

More information

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for

More information

CAMTO LTD. Arc detecting system DC/AC

CAMTO LTD. Arc detecting system DC/AC CAMTO LTD Arc detecting system DC/AC Arc detecting system DC/AC The system is based on experience with arc protection since 1962. The system units are built into boxes that all fit on a 35 mm DIN-rail.

More information

multi-function meters

multi-function meters multi-function meters eclipse 2 eclipse 7 installation and operating manual 1 GENERAL DESCRIPTION 2 INSTALLATION 3 WIRING INFORMATION 4 2 ECLIPSE 2 METERS 2.1 PROGRAMMING THE METER 5 2.2 INFORMATION 6

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

QUICK START GUIDE FLEXSLICE MODULES

QUICK START GUIDE FLEXSLICE MODULES TECHNOLOGY POWER ETHERCAT OUT ETHERCAT IN STATUS LED S POWER AND I/O STATUS LED S USER TAB EBUS CONNECTOR LOCK QUICK START GUIDE FLEXSLICE MODULES P366 P371 P372 P375 P376 P377 P378 P379 description The

More information

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap Description: The TR5000 is a Full Logic Control Process ratemeter that can display up to three separate values of rate and compare them to programmable set points. Rates A & B can be programmed by the

More information

Operating Manual RISH OPTIMA VAF

Operating Manual RISH OPTIMA VAF Operating Manual RISH OPTIMA VAF 2-60-006-00-00511_Rev. A - 5/2014 Section DIGITAL MULTIFUNCTION INSTRUMENT Programmable Multi-function Digital Panel Meter Installation & Operating Instructions Contents

More information

.Power Distribution Center. PD-1. Instruction Manual

.Power Distribution Center. PD-1. Instruction Manual .Power Distribution Center. PD-1 Instruction Manual www.datavideo-tek.com 1 Contents Warnings and Precautions... 3 Warranty... 4 Standard Warranty... 4 Two Year Warranty... 4 Disposal... 4 Packing List...

More information

SU17 Series Fiber Optic Sensors

SU17 Series Fiber Optic Sensors SU17 Series Fiber Optic Sensors Fiber Optic Diffuse and Thru-Beam Mode See page 750 Sensing Range: Determined by fiber optic cable Output: NPN, PNP Built-in auto-tuning Digital display Mutual interference

More information

48x24. Options ORDER NUMBER OF TYPE PFL B

48x24. Options ORDER NUMBER OF TYPE PFL B Frequency metering (0.01 Hz 9999 Hz) with 2 setpoints Free scalable indication and setpoints from 0 up to +9999 Standard: min/max memory - option: analogue output Allow to be placed side by side in grid

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200

More information

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data Product description Dimmable built-in for LED Constant current (with 2 adjustable output channels) Designed for outdoor and street luminaire Output power 2 x 38 W Suitable for mains voltage peaks (burst/surge)

More information

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP SINGLE/TWO CHANNEL 24HR/7 DAY TIMER Cat No. TR671/TR672TOP INSTALLATION & OPERATING INSTRUCTIONS TR671/TR672TOP 24Hr/7 Day 1/2 Channel Digital TOP Module (without Power Supply) Please read the instructions

More information

STD-525T PRECISION TIMER

STD-525T PRECISION TIMER FN:STD525TM1.DOC STD-525T PRECISION TIMER DESCRIPTION The STD-525T Precision Timer measures and displays accurate elapsed time in minutes, seconds, tenths of seconds, and hundredths of seconds (MM.SS.TH)

More information

Operating Instructions

Operating Instructions COUNTERS CONTROLLERS ENCODERS Operating Instructions Electronic preselection counter Contents Page 1 General Information / Safety instructions 2 2 Getting to know the counter 4 2.1 Counter components 4

More information

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Description. Specifications and Ordering Information 1900/27 Vibration Monitor R Specifications and Ordering Information 1900/27 Vibration Monitor Description The 1900/27 is a single-channel, stand-alone, locally mounted vibration monitor. It can be used as a stand-alone machinery

More information

Preset counters, electronic

Preset counters, electronic With its automatic help texts, clearly and legibly displayed on 14 LED segments, the Codix 560 preset counter takes the user effortlessly through the programming. The large user-friendly front keys can

More information

Electrical connection

Electrical connection (I)GSU 14C Ultrasonic Label Fork Dimensioned drawing en 06-2011/12 50109234-01 4mm 12-30 V DC 4 m/s We reserve the right to make changes DS_IGSU_14C_en.fm Ultrasonic forked sensor for universal application

More information

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL INTRODUCTION The Gemini 5200 is another unit in a multi-purpose series of industrial control products that are field-programmable to solve multiple

More information

Cronotermostato Digitale

Cronotermostato Digitale Cronotermostato Digitale CHRONOS KEY Manuale d Uso User Manual DIGITAL PROGRAMMABLE THERMOSTAT Index Dimensions Page 4 Connection diagram Page 4 Safety warnings Page 5 Technical specifications Page 6 Display

More information

Timer and switching relays Timers. Function timer relay. Additional function relay. Timer and switching relay

Timer and switching relays Timers. Function timer relay. Additional function relay. Timer and switching relay Timer and switching relay Timer and switching relays Timers Power-on delayed Power-off delayed Power-on and power-off delayed Switch-on and/or switch-off wiping (pulse shaper) Function timer relay Clock

More information

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing ADVANCED ultrasonic sensors with analog output Dimensioned drawing en 07-2017/02 50124880 4...20 ma 0...10 V 25 400mm 150 1300mm 15-30 V DC We reserve the right to make changes PAL_DMU418BX3LTVC_en_50124880.fm

More information

Simply clever! The digital DIN-rail time switches by Grässlin

Simply clever! The digital DIN-rail time switches by Grässlin Simply clever! The digital DIN-rail time switches by Grässlin talento pro Trends and developments on the market. Maximum energy efficiency at low efforts In a saturated fast-moving market, the trend towards

More information

Light Curtain Type LA

Light Curtain Type LA Light Curtain Type LA Status: 2011-04-27 Subject to change without notice. No responsibility is taken for the correctness of this information. Your suggestions for corrections or improvements are welcome!

More information

K3NX Process Meter OPERATION MANUAL

K3NX Process Meter OPERATION MANUAL Cat.No. N90 E1 1 K3NX Process Meter OPERATION MANUAL K3NX Process Meter Operation Manual Produced January 1998 Notice: OMRON products are manufactured for use according to proper procedures by a qualified

More information

Time-Lag Relays. User s Handbook (General Model)

Time-Lag Relays. User s Handbook (General Model) Time-Lag Relays User s Handbook (General Model) 651.601.387 Rev: V39 Date: 09/2016 Electrotécnica Arteche Smart Grid, S.L. This document, including texts, photos, graphics and any other content, is protected

More information

XT-17M-B relay - Delay-off, 1 C/O, 16 A

XT-17M-B relay - Delay-off, 1 C/O, 16 A - Delay-off, 1 C/O, 16 A Datasheet Features Delay-off Single function Time ranges: XT-17M-B1 0.1...1 s XT-17M-B2 1...10 s XT-17M-B3 6...60 s XT-17M-B4 1...10 min XT-17M-B5 6...60 min XT-17M-B6 1...10 h

More information

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Z-D-IN. RS485 Modbus Module 5 Digital Inputs S SENECA Z-PC Line EN Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - Modbus connection rules - DIP-switches Settings -

More information

CODIX 560. Elektronischer Vorwahlzähler mit zwei Vorwahlen. Electronic Preset Counter With two presets

CODIX 560. Elektronischer Vorwahlzähler mit zwei Vorwahlen. Electronic Preset Counter With two presets CODIX 560 Elektronischer Vorwahlzähler mit zwei Vorwahlen Electronic Preset Counter With two presets Compteur à présélection électronique avec deux présélections Contatore elettronico a preselezione con

More information

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver.   Product description. Benefits. Interfaces. Constant current LED driver DALI Dimmable Product description Dimmable Independent constant current Adjustable output current between 350 and 1,050mA via DIP switch Max. output power 35 W Up to 88 % efficiency

More information

Tech Support: Customer Service: General Tech Questions: Tech Docs:

Tech Support: Customer Service: General Tech Questions: Tech Docs: Tech Support: 1-800-407-4545 Customer Service: 1-800-523-2462 General Tech Questions: Tech_Services@beainc.com Tech Docs: www.beasensors.com BR3-X Programmable 3 Relay Advanced Logic Module & Restroom

More information

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Warner Photoscanner MCS-500 Series LED Photoelectric Control Warner Photoscanner MCS-500 Series LED Photoelectric Control P-241-100 819-0504 Installation & Operating Instructions Contents Description.............................. 2 Specifications.........................

More information

CET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES

CET DOUBLE COUNTER WITH TWO THRESHOLDS LBM62CD. Type: TECHNICAL FEATURES CET DOUBLE COUNTER WITH TWO THRESHOLDS Type: LBM62CD 6 DIGITS DOUBLE DIGITAL COUNTER WITH TWO SEPARATE COUNT IMPUTS LBM62CD counter is a double counter with two separate counters. Each counter s input

More information

Operating Manual. Basic Control BC16. two-channel for eco moon

Operating Manual. Basic Control BC16. two-channel for eco moon Operating Manual Basic Control BC16 two-channel for eco moon Dear Customer, Thank you for choosing a WALTRON daytime lighting controller. Your daytime lighting controller is a high-quality product that

More information

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay. TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay. On-Delay: Provides a delay period on energization, at the end of which the switch contacts transfer. De-energizing

More information

Eaton Durant. Counters, process instruments and hour meters.

Eaton Durant. Counters, process instruments and hour meters. Alltid Always tillgänglig available - Alltid öppen! - Always open! Electronic totalizers, LCD display - 1/32 DIN 24x mm Eaton Durant Catalogue Weight Type number kg/each Totalizer, add/subtract, NPN/PNP

More information

Model Number Structure

Model Number Structure Cycle Control Units CSM DS_E_7_1 Refer to Safety Precautions for All Power Controllers. Used in Combination with the to Enable High-precision Temperature Control Use cycle control to achieve power control

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

AX 345. Process Indicator with Two Analogue Inputs, Calculations and Programmable Analogue Output. Operating Instructions for Model AX 346

AX 345. Process Indicator with Two Analogue Inputs, Calculations and Programmable Analogue Output. Operating Instructions for Model AX 346 control motion interface motrona GmbH Zwischen den Wegen 32 78239 Rielasingen - Germany Tel. +49 (0)7731-9332-0 Fax +49 (0)7731-9332-30 info@motrona.com www.motrona.com AX 346 Process Indicator with Two

More information

263 Series LED Bargraph Indicator and Controllers

263 Series LED Bargraph Indicator and Controllers 263 Series LED Bargraph Process Control Water Treatment High resolution 51 segment LED Bargraph for easy reading Accuracy 1% Red display Vertical or Horizontal mounting & stackable Connection Diagrams

More information

Self--powered Time Counter

Self--powered Time Counter Self--powered Time Counter Subminiature Time Counters With Enhanced Appearance and Features Large display with 8.6 mm (0.338 in) height Available with backlit LCD PNP/NPN DC voltage available Sevendigits,timerange0to

More information

Electrical connection

Electrical connection Color sensors Dimensioned drawing en 02-2013/01 50121262 068-14515 12mm 32mm 10-30 V DC 500 Hz Scanner for color detection Simultaneous selection of up to 3 colors Detection independent of distance Teach-in

More information

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver.   Product description. Benefits. Interfaces. Linear / area dimming Constant current LED driver DALI Dimmable Product description Dimmable built-in constant current LED Driver Adjustable output current between 1,050 and 1,750mA via DIP switch Max.

More information

THE ASTRO LINE SERIES GEMINI 1000/2000 INSTRUCTION MANUAL

THE ASTRO LINE SERIES GEMINI 1000/2000 INSTRUCTION MANUAL THE ASTRO LINE SERIES GEMINI 1000/2000 INSTRUCTION MANUAL INTRODUCTION The Gemini 1000 and 2000 are both units in a multi-purpose series of industrial control units that are field-programmable to solve

More information

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output

1. Overview. SSI-1016G interfaces with 24, 25 and 26 bit Temposonics SSI sensor. Block diagram. as PNP open collector output SSI-1016G Manual Caution: Specifications and outline may be changed without notice MTS Sensors Technology Corporation www.mtssensor.co.jp 2010.02.04 Rev. 1 1 Revision information 2007.03.12: Data-ready

More information

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T

Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T DM 4-2 T 4940280 DM 8-2 T 4940285 Updated: Jun-16 (Subject to change) Page 1 of 70 Contents 1 FUNCTIONAL CHARACTERISTICS... 4 1.1 OPERATION... 5 2

More information

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie. Q Dimensions Transmitter Detection field + 9. Detection field 7.8 n Beam. Beam Receiver III 0. 0 Fix H H H Fn Model Number Light grid with fixed cable with -pin, M x connector, and fixed cable with 8-pin,

More information

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Broadcast Devices, Inc. AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web:

More information

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians

Radio receiver EXL. 4-channel / up to 1000 memory locations. Mounting and operating instructions for qualified electricians Radio receiver EXL 4-channel / up to 1000 memory locations Mounting and operating instructions for qualified electricians Please keep these instructions so that you have them available if you have any

More information

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE JY992D52801C This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX-2DA special

More information

M1020 Programmable Limit Switch (PLS)

M1020 Programmable Limit Switch (PLS) M1020 Programmable Limit Switch (PLS) Instruction & Operation Manual Sales and Marketing 343 St. Paul Blvd. Carol Stream, IL 60188 Tel: (630)668-3900 FAX: (630)668-4676 Factory Customer Service/Order Entry

More information

Time meter electronic

Time meter electronic Time meter electronic Universal with dual functions CODIX 52U 000000 0... 30V DIN 24 x 48 Power supply dimensions -0 +50 65 Wide temperature range High IP protection rating Powerful Fast count input Input

More information

ISE, Inc Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440) B Long Ranger Timer

ISE, Inc Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440) B Long Ranger Timer ISE, Inc. 10100 Royalton Rd. Cleveland, OH 44133 USA Tel: (440) 237-3200 Fax: (440) 237-1744 http://instserv.com 365B Long Ranger Timer INSTALLATION INSTRUCTION November, 2000 3-0365-095-04-00 DESCRIPTION:

More information