Parts List _2.1. Flygt /.190

Size: px
Start display at page:

Download "Parts List _2.1. Flygt /.190"

Transcription

1 Parts List _2. Flygt /.90

2 Table of Contents Table of Contents Introduction Specially approved products Product Description The data plate Approvals Product denomination Exploded View Exploded view N-pumps List of Parts / Flygt 3069 Parts List

3 Introduction Introduction Purpose of this manual Disclaimer Data for ordering spare parts The purpose of this manual is to provide necessary information on spare parts and accessories order. Always use genuine Flygt parts. The use of other spare parts or accessories can invalidate any claims for warranty or compensation. Xylem does not take any responsibility for damages that are caused by the use of non-original parts. For more information, contact your local sales and service representative. The following information is needed for spare part orders: Serial number of the product Part number Quantity of bulk material, see * in tables. Specially approved products Qualification of personnel Dimensional accuracy inspection Only Xylem or Xylem-authorized service personnel may undertake repair work on specially approved products. Spare parts marked with (Ex) after the part number are subject to dimensional accuracy inspection when used in specially approved products. 2 Flygt 3069 Parts List

4 2 Product Description 2 Product Description Products included Pump D-hydraulic F-hydraulic M-hydraulic (Grinder) N-hydraulic, cast iron MT, SH MT, SH Explosion proof drive unit N-hydraulic, Hard-Iron N-hydraulic, stainless steel Pump-specific information For the specific weight, current, voltage, power ratings, and speed of the pump, see the data plate of the pump. 2. The data plate The data plate is a metal label that is located on the main body of the products. The data plate lists key product specifications. Specially approved products also have an approval plate WS006257A. Curve code or Propeller code 2. Serial number 3. Product number 4. Country of origin 5. Additional information 6. Phase; type of current; frequency 7. Rated voltage 8. Thermal protection 9. Thermal class 0.Rated shaft power.international standard 2.Degree of protection 3.Rated current 4.Rated speed 5.Maximum submergence 6.Direction of rotation: L=left, R=right 7.Duty class 8.Duty factor 9.Product weight 20.Locked rotor code letter 2.Power factor 22.Maximum ambient temperature 23.Read installation manual 24.Notified body, only for EN-approved Ex products Figure : The data plate Flygt 3069 Parts List 3

5 2 Product Description 2.2 Approvals Product approvals for hazardous locations Pump Approval European Norm (EN) ATEX Directive EN :202/A:203, EN :204, EN 3463-:2009, EN :20 II 2 G c Ex db IIB T3 Gb II 2 G c Ex db IIB T4 Gb IEC IECEx scheme IEC , IEC Ex d IIB T3 Gb Ex d IIB T4 Gb FM (FM Approvals) Explosion proof for use in Class I, Div., Group C and D EN approval plate This illustration describes the EN approval plate and the information that is contained in its fields WS003972B. Approval 2. Approval authority and Approval number 3. Approved for drive unit 4. Cable entry temperature 5. Stall time 6. Starting current or Rated current 7. Duty class 8. Duty factor 9. Input power 0.Rated speed.additional information 2.Maximum ambient temperature 3.Serial number 4.ATEX marking IEC approval plate This illustration describes the IEC approval plate and the information that is contained in its fields. International Norm; not for EU member countries WS00279C. Approval 2. Approval authority and Approval number 3. Approved for drive unit 4. Cable entry temperature 5. Stall time 6. Starting current or Rated current 7. Duty class 8. Duty factor 9. Input power 0.Rated speed.additional information 2.Maximum ambient temperature 3.Serial number 4.ATEX marking 4 Flygt 3069 Parts List

6 2 Product Description FM approval plate This illustration describes the FM approval plate and the information that is contained in its fields.. Temperature class 2. Maximum ambient temperature 2 WS003973A CSA approval plate This illustration describes the CSA approval plate and the information that is contained in its fields.. Temperature class WS00940A 2.3 Product denomination Reading instruction In this section, code characters are illustrated accordingly: X = letter Y = digit The different types of codes are marked up with a, b and c. Code parameters are marked up with numbers. Codes and parameters XXYYYY. YYY YYY YYYY a b c Type of Callout Number Indication Type of code a Sales denomination b c WS006265B Product code Serial number Flygt 3069 Parts List 5

7 2 Product Description Type of Callout Number Indication Parameter Hydraulic end 2 Type of installation 3 Sales code 4 Version 5 Production year 6 Production cycle 7 Running number 6 Flygt 3069 Parts List

8 3 Exploded View 3 Exploded View 3. Exploded view A Flygt 3069 Parts List 7

9 3 Exploded View 3.2 N-pumps SH DN50 SH DN65/DN80 MT DN SH DN50 63 MT DN SH DN50 79 MT DN A 8 Flygt 3069 Parts List

10 4 List of Parts 4 List of Parts /.90 Pos. No Part. No Type Denomination Qty/Version Lifting handle Hex.socket hd screw ISO 4762 M 8 X35-A (Ex) Data plate Hex.socket hd screw M6X6-A Drive screw 4X5-A2/A Drive screw 4X5-A2/A Stator housing Stator housing Housing for CSA Canada (Ex) Stator housing Hex.socket hd screw M8X35-A Data plate O-ring 56X3 NBR Ball bearing Z Shaft unit (Ex) Shaft unit (Ex) Shaft unit Shaft unit (Ex) Shaft unit Stator b 50 Hz 2-poles 220V-230V D 380V-400V Y P2=,70kW 60 Hz 2-poles 440V-480V Y P2=2kW/2,70hp Stator b 50 Hz 2-poles 45V-440V Y P2=,70kW Stator b 50 Hz 2-poles 500V-550V Y P2=,70kW 60 Hz 2-poles 575V-600V Y P2=2kW/2,70hp 60 Hz 2-poles 575V-600V Y P2=,50kW/2hp Stator b 50 Hz 2-poles 400V D 690V Y P2=,70kW Stator b 60 Hz 2-poles 220V-230V Y// 440V-460V YSER P2=2kW/2,70hp Stator b 50 Hz 2-poles 90V-200V Y P2=,70kW 60 Hz 2-poles 200V-220V Y P2=2kW/2,70hp 60 Hz 2-poles 200V-220V Y P2=,50kW/2hp Stator b 60 Hz 2-poles 220V D 380V Y P2=2kW/2,70hp Flygt 3069 Parts List 9

11 4 List of Parts Pos. No Part. No Type Denomination (Ex) Stator 3-0-2b -phase 50 Hz 2-poles 220V-240V P2=,50kW (Ex) Stator 3-0-2b -phase 60 Hz 2-poles 220V-240V P2=,70kW/2,30hp Stator 3-0-2b 50 Hz 2-poles 220V-230V D 380V-400V Y P2=2,40kW 60 Hz 2-poles 440V-480V Y Max P=2,80KW 50 Hz 2-poles 220V-230V D 380V-400V Y Max P=2,50KW 60 Hz 2-poles 440V-480V Y P2=2,80kW/3,80hp Stator 3-0-2b 50 Hz 2-poles 45V-440V Y P2=2,40kW 50 Hz 2-poles 45V-440V Y Max P=2,50KW Stator 3-0-2b 50 Hz 2-poles 500V-550V Y P2=2,40kW 60 Hz 2-poles 575V-600V Y P=2,70KW 50 Hz 2-poles 500V-550V Y Max P=2,50KW 60 Hz 2-poles 575V-600V Y P2=2,80kW/3,80hp Stator 3-0-2b 50 Hz 2-poles 400V D 690V Y P2=2,40kW 50 Hz 2-poles 400V D 690V Y P=2,40KW Stator 3-0-2b 60 Hz 2-poles 230V-240V Y// 460V-480V YSER P2=2,80kW/ 3,80hp Stator 3-0-2b 50 Hz 2-poles 90V-200V Y P2=2,40kW 60 Hz 2-poles 200V-220V Y Max P=2,90KW 50 Hz 2-poles 90V-200V Y Max P=2,50KW 60 Hz 2-poles 200V-220V Y P2=2,80kW/3,80hp Stator 3-0-2b 60 Hz 2-poles 220V-230V D 380V-400V Y Max P=2,80KW 60 Hz 2-poles 220V-230V D 380V-400V Y P2=2,80kW/3,80hp Stator 3-0-2b 60 Hz 2-poles 200V-208V Y Max P=2,80KW 60 Hz 2-poles 200V-208V Y P2=2,80kW/3,80hp Stator b 50 Hz 4-poles 230V D 400V-45V Y P2=,50kW 60 Hz 4-poles 460V-480V Y P2=,80kW/2,40hp Qty/Version Stator b 50 Hz 4-poles 440V Y P2=,50kW 0 Flygt 3069 Parts List

12 4 List of Parts Pos. No Part. No Type Denomination Stator b 50 Hz 4-poles 500V Y P2=,50kW 60 Hz 4-poles 575V-600V Y P2=,80kW/2,40hp Stator b 50 Hz 4-poles 400V D 660V-690V Y P2=,50kW Qty/Version Stator b 50 Hz 4-poles 200V Y P2=,50kW Stator b 60 Hz 4-poles 220V-230V D 380V Y P2=,80kW/2,40hp Stator b 60 Hz 4-poles 200V-208V Y P2=,80kW/2,40hp Stator b 60 Hz 4-poles 400V-45V Y P2=,80kW/2,40hp Stator b 50 Hz 4-poles 220V D 380V Y P2=,50kW Stator b 50 Hz 4-poles 550V Y P2=,50kW Stator b 60 Hz 4-poles 230V-240V Y// 460V YSER P2=,80kW/2,40hp Stator 3-0-4b phs -phase 50 Hz 4-poles 220V-240V P2=,30kW Stator 3-0-4b phs -phase 60 Hz 4-poles 230V-240V P2=0,97kW/,30hp -phase 60 Hz 4-poles 230V-240V P2=,50kW/2hp Stator 3-0-4b 50 Hz 4-poles 400V-45V Y P2=2kW 60 Hz 4-poles 440V-480V Y P=2,50KW 50 Hz 4-poles 400V-45V Y Max P=2,30KW 60 Hz 4-poles 440V-480V Y P2=2,40kW/3,20hp Stator 3-0-4b 50 Hz 4-poles 440V Y P2=2kW 50 Hz 4-poles 440V Y P=2,20KW Stator 3-0-4b 50 Hz 4-poles 500V Y P2=2kW 60 Hz 4-poles 575V-600V Y P=2,50KW 50 Hz 4-poles 500V Y P=2,20KW 60 Hz 4-poles 575V-600V Y P2=2,40kW/3,20hp Stator 3-0-4b 50 Hz 4-poles 400V D 690V Y P2=2kW 50 Hz 4-poles 400V D 690V Y P=2,20KW Stator 3-0-4b 50 Hz 4-poles 200V Y P2=2kW 50 Hz 4-poles 200V Y P=2,20KW Stator 3-0-4b 60 Hz 4-poles 220V-230V D 380V Y Max P=2,60KW 60 Hz 4-poles 220V-230V D 380V Y P2=2,40kW/3,20hp Flygt 3069 Parts List

13 4 List of Parts Pos. No Part. No Type Denomination Stator 3-0-4b 60 Hz 4-poles 200V-208V Y P=2,50KW 60 Hz 4-poles 200V-208V Y P2=2,40kW/3,20hp Stator 3-0-4b 60 Hz 4-poles 400V Y P=2,50KW 60 Hz 4-poles 400V Y P2=2,40kW/ 3,20hp Stator 3-0-4b 50 Hz 4-poles 220V D 380V Y P2=2kW 50 Hz 4-poles 220V D 380V Y P=2,30KW Stator 3-0-4b 50 Hz 4-poles 550V Y P2=2kW 50 Hz 4-poles 550V Y P=2,20KW Stator 3-0-4b 60 Hz 4-poles 230V-240V Y// 460V YSER P=2,50KW 60 Hz 4-poles 230V-240V Y// 460V YSER P2=2,40kW/3,20hp Qty/Version Motor cable subcab 4G.5 * * Motor cable subcab 4G2.5 * * Motor cable subcab 4G.5+2X.5 * * Motor cable subcab 4G2.5+2X.5 * * Motor cable subcab 7G2.5+2X.5 * * Motor cable subcab S3X.5+3X.5/3+S(2X0.5) Motor cable subcab S3X2.5+3X2.5/3+S(4X0.5) * * * * Cable unit Leakage sensor (FLS) Bearing holder GD-AL (Ex) Bearing holder Ball bearing 20X52X5 MM Mechanical seal AL2O3/CARBON FPM Mechanical seal WCCR/WCCR FPM Seal washer Plug Mechanical seal AL2O3/WCCR FPM Mechanical seal WCCR/WCCR FPM Sleeve Impeller unit MT Curve code: Impeller unit MT Curve code: Impeller unit MT Curve code: Impeller unit MT Curve code: Impeller unit MT Curve code: Impeller unit SH Curve code: Impeller unit SH Curve code: Impeller unit SH Curve code: Flygt 3069 Parts List

14 4 List of Parts Pos. No Part. No Type Denomination Qty/Version Impeller unit SH Curve code: Impeller unit SH Curve code: Pump housing MT N DN 80 Drilled acc. to: EN tab. 9 ANSI B6.-89; tab.5 Installation: X Outlet diameter (mm): Pump housing SH N DN 65 Installation: X Outlet diameter (mm): Pump housing SH N DN 80 Installation: X Outlet diameter (mm): Pump housing SH N DN 50 Installation: X Outlet diameter (mm): (Ex) Pump housing MT N DN 80 Drilled acc. to: EN tab. 9 ANSI B6.-89; tab.5 Installation: X Outlet diameter (mm): (Ex) Pump housing SH N DN 65 Installation: X Outlet diameter (mm): (Ex) Pump housing SH N DN 80 Installation: X Outlet diameter (mm): (Ex) Pump housing SH N DN 50 Installation: X Outlet diameter (mm): Supporting washer Hex.socket hd screw M8X50-A Suction cover MT Insert ring SH Hex.socket hd screw M6X6-A Retaining ring SGH Sealing washer DUBO NR Plain washer 24.5X35X2-A Seal sleeve (0)-2 MM NBR Seal sleeve (2)-4 MM NBR Seal sleeve (4)-6 MM NBR Seal sleeve (6)-8 MM NBR Seal sleeve (20)-22 MM NBR Seal sleeve (8)-20 MM NBR (Ex) Cable clip 0-(2) MM (Ex) Cable clip 2-(4) MM (Ex) Cable clip 4-(6) MM (Ex) Cable clip 6-(8) MM (Ex) Cable clip 20-(22) MM (Ex) Cable clip 8-(20) MM (Ex) Gland screw Pr Cutting screw TAPTITE-M6X Cable lug UL/CSA MM2 M Cable lug UL/CSA MM2 M6 Flygt 3069 Parts List 3

15 4 List of Parts Pos. No Part. No Type Denomination Qty/Version Terminal block 600V/20A UL Terminal block 600V/20A UL Closed-end splice (AWG 8) Closed-end splice 3-6 (AWG 2-0) Terminal block 600V/20A UL Terminal block 600V/20A UL Terminal block 600V/20A UL O-ring kit Basic repair kit AL2O3/WCCR AL2O3/C Basic repair kit WCCR/WCCR AL2O3/C Basic repair kit WCCR/WCCR WCCR/WCCR Oil ISO VG 32 * * 4 Flygt 3069 Parts List

Parts List _2.1. Flygt /.890

Parts List _2.1. Flygt /.890 Parts List 886754_2. Flygt 3069 3069.70/.890 Table of Contents Table of Contents Introduction... 2. Specially approved products... 2 2 Product Description...3 2. The data plate...3 2.2 Approvals...4 2.3

More information

Flygt Handleiding voor installatie, bediening en onderhoud

Flygt Handleiding voor installatie, bediening en onderhoud Flygt 068 Handleiding voor installatie, bediening en onderhoud Table of Contents Table of Contents 1 Introduction... 1.1 Specially approved products... Product Description....1 The data plate.... Approvals...4.

More information

Flygt /190. Parts List

Flygt /190. Parts List Flygt 3127.160/190 Parts List Table of Contents Table of Contents Introduction...2 Purpose of this manual...2 Disclaimer...2 Data for ordering spare parts...2 Specially approved products...2 Qualification

More information

Revision 1.0 Parts List Mega

Revision 1.0 Parts List Mega Revision.0 www.grindex.com Parts List 824.390 Mega Table of Contents Table of Contents Introduction... 2. Specially approved products... 2 2 Product Description...3 2. Products included... 3 2.2 The data

More information

Revision 1.0 Parts List Mega

Revision 1.0 Parts List Mega Revision.0 www.grindex.com Parts List 824.400 Mega Table of Contents Table of Contents Introduction... 2 Specially approved products...2 Product Description...3 The data plate...3 Exploded Views...4 Drive

More information

Revision 3.0 Parts List Salvador 1~, 3~

Revision 3.0 Parts List Salvador 1~, 3~ Revision 3.0 www.grindex.com Parts List 809.8 Salvador ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data

More information

Revision 2.0 Parts List Minette 1~, 3~

Revision 2.0 Parts List Minette 1~, 3~ Revision.0 www.grindex.com Parts List 80.7 Minette ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data plate...3

More information

Revision 2.0 Parts List Minor

Revision 2.0 Parts List Minor Revision.0 www.grindex.com Parts List 803.8 Minor Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data plate...3 Exploded

More information

Revision 1.0 Parts List Salvador 1~, 3~

Revision 1.0 Parts List Salvador 1~, 3~ Revision.0 www.grindex.com Parts List 809.8 Salvador ~, 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 The data plate...3 Parts... 4 Exploded

More information

Revision 1.0 Parts List Minor

Revision 1.0 Parts List Minor Revision.0 www.grindex.com Parts List 803.8 Minor Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 The data plate...3 Parts... 4 Exploded view...

More information

Revision 3.0 Parts List Minex 1~ Minex Lite, Minex 3~

Revision 3.0 Parts List Minex 1~ Minex Lite, Minex 3~ Revision 3.0 www.grindex.com Parts List 80.60 Minex ~ 80.7 Minex Lite, Minex 3~ Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included...

More information

Revision 1.0 Parts List Mini

Revision 1.0 Parts List Mini Revision.0 www.grindex.com Parts List 822.2 Mini Table of Contents Table of Contents Introduction... 2 Specially approved products...2 Product Description...3 Products included... 3 The data plate...3

More information

Flygt D 8050, 50 Hz. Technical specification

Flygt D 8050, 50 Hz. Technical specification Flygt D 8050, 50 Hz Technical specification Table of Contents Table of Contents D 8050... 2 Product... 2 Denomination... 2 Process data... 2 Motor data...2 Cable...2 Monitoring equipment... 2 Material...

More information

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V)

Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V) Data sheet: Wilo-Drain TP 50 E 101/5,5 (1~230 V) Pump curves Wilo-Drain TP 50 E - 50 Hz - 2900 rpm Unit Max. delivery head H max 9.5 m Max. volume flow Q max 26 m 3 /h Optimal delivery head H opt 5.0 m

More information

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V) Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V) Pump curves Wilo-Drain TP 65 E - 50 Hz - No. of poles: 2 Unit Max. delivery head H max 15.0 m Max. volume flow Q max 52.0 m 3 /h Optimal delivery head H

More information

Pendant Light Fitting IEC Series 6470/2

Pendant Light Fitting IEC Series 6470/2 > Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E

More information

EXPlora. Introduction

EXPlora. Introduction Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant

More information

Flygt Submersible Motor Cables

Flygt Submersible Motor Cables Flygt Submersible Motor Cables This brochure contains an overview of the Flygt motor cable assortment. The cables are especially designed for submersible use and made of carefully selected materials. The

More information

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A

Roots pumps with a pumping speed of 280 to 840 m 3 /h: Okta 500 DUO DN1 DN B A 3.1 Vacuum generation / / Convection cooled OktaLine Okta 500 with a pumping speed of 280 to 840 m 3 /h: High-performance Roots pump with a pumping speed of 280 to 840 m 3 /h With 3-phase motor, IE2 No

More information

Phone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h

Phone Horizontal Multistage Pumps Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h Horizontal Stainless Steel Multistage Pumps 3, 6, 9 m³/h Horizontal Multistage Pumps 50 Hz Stainless Steel 3-9 m3/h Model Number Explanation Example: 3AMH2B-51 3 = m 3 /h AMH = Series 2 = # of Stages

More information

82540/ /2-way diaphragm valves

82540/ /2-way diaphragm valves > > ort size: DN 8... 50, 1/4... 2 (ISO G/NT) > > Valve operates without differential pressure > > High flow rate > > For robust industry solutions > > Damped operation > > Suitable for vacuum > > Solenoid

More information

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO. DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:

More information

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump

Dewatering. Series description Wilo-Drain STS 65. Submersible sewage pump Series description Wilo-Drain STS 65 Thermal winding monitoring Max. fluid temperature: 3-40 C Cable length: 10 m Free ball passage: 65 mm Max. immersion depth: 10 m Equipment/function Thermal motor monitoring

More information

Immersion Pumps HCT (High Chem) sealless EN

Immersion Pumps HCT (High Chem) sealless EN Immersion Pumps HCT (High Chem) sealless 1 6004 EN Centrifugal pumps of plastic for a wide variety of industrial fluids Technical data Delivery rate Q max = 120 l/min Delivery head H max = 32 m Temperature

More information

Explosion Proof Audible Signal db(a) Series YA60

Explosion Proof Audible Signal db(a) Series YA60 > Omnidirectional high output sounder 110 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > 32 selectable

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

Series description: Wilo-Sub TWU 3 HS

Series description: Wilo-Sub TWU 3 HS Series description: Wilo-Sub TWU 3 HS Design Submersible pump, multistage Application For private water supply from boreholes, wells and rainwater storage tanks For domestic water supply, sprinkling and

More information

Gear Pump Units For single-line centralized lubrication systems

Gear Pump Units For single-line centralized lubrication systems 1-1202-EN Gear ump Units For single-line centralized lubrication systems MFE5-KW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,

More information

Explosion Proof Audible Signal db(a) Series YA60

Explosion Proof Audible Signal db(a) Series YA60 > Omnidirectional high output sounder 110 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > Aluminium enclosure with stainless steel fasteners > 32 selectable

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

Series description: Wilo-Jet HWJ

Series description: Wilo-Jet HWJ Series description: HWJ 2 Design Self-priming water-supply unit Application Water supply Sprinkling Irrigation and spraying Pumping water from wells and out of low-lying tanks Type key Example: H WJ HWJ

More information

Immersion Pumps HCT (High Chem) sealless

Immersion Pumps HCT (High Chem) sealless Immersion Pumps HCT (High Chem) sealless 1-6004-US Centrifugal pumps of plastic for a wide variety of industrial fluids Technical data Delivery rate Q max = 120 l/min Delivery head H max = 32 m Temperature

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm)

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) SOGEVAC Rotary Vane Vacuum Pumps single-stage, oil-sealed, 10-1200 m 3 x h -1 (5.9-707 cfm) 172.02.02 Excerpt from the Product Section C02 Edition March 2007 Contents General Product Range, Features and

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection

More information

Bimetal Temperature Switch

Bimetal Temperature Switch Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,

More information

EXLUX ECOLUX 6480 Series

EXLUX ECOLUX 6480 Series EXLUX ECOLUX 6480 Series L I G H T I N G 6000 6008 6400 6408 6600 6608 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent

More information

Pendant Light Fittings Series 6050

Pendant Light Fittings Series 6050 > Saltwaterresistant enclosure, aluminium alloy, optionally with painting > Maintenancefree operation and long service life with induction lamp or LED > Mounting with ring bolts or tiltable mounting bracket

More information

www.mete-enerji.com.tr INDUSTIAL IEC PLUGS AND SOCKETS INDUSTIAL IEC PLUGS AND SOCKETS Position of the Earthing Contact acc. to IEC 60309-2 225/400-265/460 V~ 60 Hz (1) 3 P+N+ 3 P+ 2 P+ 120/208-144/250V~

More information

I Ex-protected connectors exlink I

I Ex-protected connectors exlink I Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity

More information

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions

SIDE CHANNEL BLOWERS. Voltage Δ / Y 2 V 230/ / / / / /460 - Current Δ / Y Revolutions DB411/415/422/ DESCRIPTION Dutair blowers for pressure and vacuum are compact machines consisting of an electric motor with a built-on pump housing. The rotational speed of the impeller creates a high

More information

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems

SOGEVAC. Rotary Vane Vacuum Pumps single-stage, oil-sealed, m 3 x h -1 ( cfm) Central Vacuum Supply Systems SOGEVAC Rotary Vane Vacuum Pumps single-stage, oil-sealed, 10-1200 m 3 x h -1 (5.9-707 cfm) Central Vacuum Supply Systems 172.02.02 Excerpt from the Product Section C02 Edition 2010 Contents General Product

More information

Product Data Sheet 4656 ZW

Product Data Sheet 4656 ZW The engineer's choice 4656 ZW INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

Series description: Wilo-Drain VC

Series description: Wilo-Drain VC Series description: Wilo-Drain VC 0H[m] 18 16 14 12 10 8 6 4 2 VC 32/10 Wilo-Drain VC 0 2 4 6 8 10 12 VC 40/20 Q[m³/h] Design Vertically-mounted drainage pump (pedestal pump with IE2 motor) Application

More information

Circuit-Breakers for Motor Protection Series 8523/8

Circuit-Breakers for Motor Protection Series 8523/8 > Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting

More information

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor With analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation

More information

8 Installation Equipment

8 Installation Equipment 8 Installation Equipment Plugs and Sockets SolConeX Series 7570, 7571 CES Series 7575, 7579, 7581 10342E00 The plugs and sockets in the CES system comply with IEC/EN 60 309-1/ -2 (CEE). The small 16 A

More information

EXLUX ECOLUX C-LUX 6480 Series

EXLUX ECOLUX C-LUX 6480 Series EXLUX ECOLUX C-LUX 6480 Series 6000 6008 6400 6408 6600 6608 6500 6480 Explosion Protected Fluorescent Luminaires for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft

More information

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/10 Type 605055, Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat and double thermostat with capillary or rigid thermowell

More information

SMALL OIL SEALED PUMPS

SMALL OIL SEALED PUMPS SMALL OIL SEALED PUMPS PERFORMANCE YOU CAN RELY ON EM0.7 and.5 Oil Sealed Rotary Vane Pumps 8 RV Oil Sealed Rotary Vane Pumps 86 RV ATEX Oil Sealed Rotary Vane Pumps 94 EM8 and 8 Oil Sealed Rotary Vane

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control IEC Contactors and Starters. XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and

More information

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122 www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals

More information

Product Data Sheet 4656 EZ

Product Data Sheet 4656 EZ The engineer's choice 4656 EZ INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Product Data Sheet 8506 VW-691

Product Data Sheet 8506 VW-691 The engineer's choice 8506 VW-691 INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 OPERATING DATA - ELECTRICAL INTERFACE

More information

Product Data Sheet 4650 N-465

Product Data Sheet 4650 N-465 The engineer's choice 4650 N-465 INDEX 1 General... 3 2 Mechanics... 3 2.1 GENERAL... 3 2.2 CONNECTIONS... 4 3 Operating Data... 5 3.1 ELECTRICAL OPERATING DATA... 5 3.2 ELECTRICAL FEATURES... 5 3.3 AERODYNAMIC...

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz Similar Image Dimensions Technical Data Ambient temperature 5-40 C Cooling method, standard

More information

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request

More information

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem

More information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information Box Fan R87B CSM_R87B_DS_E_4_4 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.

More information

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 339. Pressure Transmitter. with G ¼ flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0. DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output

More information

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model ED 400 Drying and heating chambers Classic.Line with natural convection Model ED 400 Drying and heating chambers Classic.Line with natural convection BENEFITS Uniform drying conditions thanks to APT.line technology Identical test conditions throughout the chamber interior

More information

TFRH Hygienic RTD temperature sensor. CombiTemp TM

TFRH Hygienic RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy

More information

High performance circuit breakers

High performance circuit breakers Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces, interfaces,

More information

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat

More information

PROPORTIONAL VALVES Sentronic plus

PROPORTIONAL VALVES Sentronic plus 04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital

More information

Installation and Operating Instructions Electric Vibrators HV/VFL/HF Series

Installation and Operating Instructions Electric Vibrators HV/VFL/HF Series Installation and Operating Instructions Electric Vibrators HV/VFL/HF Series Translation of the Original Instruction Manual Würges Vibrationstechnik GmbH Daimlerstraße 9 D-86356 Neusäß Telephone +49 821

More information

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications . Ex-Escape sign luminaires Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications The robust escape sign luminaire The Ex-Lite series of explosion-protected escape sign luminaire

More information

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

GOYEN PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS PRODUCT LEAFLET PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS CLEAN AIR SOLUTIONS 3-6VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination

More information

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43 Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.

More information

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex. Guide for installers METTLER TOLEDO MultiRange System solution Point Ex www.mt.com/support System solution Point Ex Contents Contents Page 1 Safety precautions... 4 2 System overview... 5 2.1 Using the

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-12360 This is to certify that the Cable Gland with type designation(s) ADE & RE; AD; FF; MM; SP; ET; LN. Manufactured by COOPER CAPRI SAS

More information

Operating instructions

Operating instructions 108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.

More information

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic. DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar

More information

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder

EXEL. Ex de. - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22. G13 bi-pin lamp holder EXEL - Double locking system operated by hexagonal-head tool - Double channel electronic ballast - Zones 1, 2, 21, 22 Reinforced polyester resin body G13 bi-pin lamp holder Internal emergency batteries

More information

Coils for solenoid valves

Coils for solenoid valves MAKING MODERN LIVING POSSIBLE Technical leaflet Coils for solenoid valves www.danfoss.com B and A coils Encapsulated coils with long operating life, even under extreme conditions Standard coils for a.c.

More information

Gear Pump Units. For single-line lubrication systems

Gear Pump Units. For single-line lubrication systems Gear Pump Units 1-1202-US For single-line lubrication systems MFE5-KW3-2 MFE5-BW3-2 MFE5-KW6 MFE5-BW7 These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated,

More information

GRUNDFOS alldos product information. The solution for complex dosing tasks

GRUNDFOS alldos product information. The solution for complex dosing tasks GRUNDFOS alldos product information The solution for complex dosing tasks Measurements Measurements a h d Electric actuator b Pneumatic actuator g e Ø 9mm k f i m 1 m 2 k j c n l 1 l 2 DMH model Measurements

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626) CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA 91746 (626) 330-3182 Fax (626) 330-9406 www.centralblower.com CATALOG REF-11 OCTOBER 2011 Series RE Scoop with Grease Trough Sealed to blower

More information

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Sentronic PLUS Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control . XT Family of Contactors Contactors and Starters Product Description The Eaton XT contactors and starters includes nonreversing and reversing contactors, overload relays and a variety of related accessories.

More information

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626) CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA 91746 (626) 330-3182 Fax (626) 330-9406 www.centralblower.com CATALOG REF - 01 JULY, 2001 Series RE Scoop with Grease Trough Sealed to blower

More information

Level Measurement Point level measurement RF Capacitance switches

Level Measurement Point level measurement RF Capacitance switches Siemens AG 2018 Overview Configuration Installation Standpipes 50 (2) 20 (0.79) max. is a compact, 2-wire, inverse frequency shift capacitance switch for level and material detection in constricted spaces,

More information

Horn loudspeaker, Ex proof, short/long flare

Horn loudspeaker, Ex proof, short/long flare Horn loudspeaker, Ex proof, short/long flare LH3 UC25XS, LH3 UC25XL en Installation note Horn loudspeaker, Ex-proof, short/long flare Installation en 3 1 Installation 1 2 Figure 1.1 Figure 1.2 4X Figure

More information

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 922 EX Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge, moves up and down its

More information

Process transmitter RMA422

Process transmitter RMA422 Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set

More information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure Box Fan R87B CSM_R87B_DS_E_4_2 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.

More information

PARTS LIST FOR CM-1250-A/C 1.5 HP

PARTS LIST FOR CM-1250-A/C 1.5 HP 8650 Enterprise Drive, Peosta IA 52068 563-556-7484 / Fax 563-556-1235 PARTS LIST FOR CM-1250-A/C Motor Specs: Pump Oil: Pump Oil Capacity: Nozzle Size: 1.5 HP / 1 Phase / 115 Volts Mi-T-M #AW-4085-0016

More information

3M Distribution Box (DDB)

3M Distribution Box (DDB) 3M Distribution Box (DDB) Merged Copper and Fiber Pole/Post Mount Enclosure Installation Instructions November 2015 78-0015-2736-1-A 2 November 2015 78-0015-2736-1-A Contents 1.0 General 2.0 Enclosure

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218 9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,

More information

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Limit switches and pulse output Batch control The MAG 6000 I/6000 I Ex is a microprocessorbased transmitter with a builtin alphanumeric display in several languages. The transmitters evaluate

More information