VectorStar ME7838E 2-Port Broadband/Banded Millimeter-Wave System
|
|
- Griffin Woods
- 5 years ago
- Views:
Transcription
1 Quick Start Guide VectorStar ME7838E 2-Port Broadband/Banded Millimeter-Wave System High Performance Modular Broadband/Banded Millimeter-Wave Vector Network Analyzer (VNA) Measurement System, 70 khz to 110 GHz This guide provides quick setup instructions for the ME7838E Broadband/Banded mm-wave VNA System assembly. For additional safety and compliance information, and for more details about the assembly, configuration, setup, and test of the equipment, refer to the VectorStar ME7838 Series Broadband/Millimeter-Wave System Installation Guide , found on the CD-ROM or at the Anritsu web site ( ME7838E Main Components The ME7838E Broadband system consists of the MS447B VNA with Option 007 (Receiver Offset), Option 070 (70 khz Low End Frequency Extension), Option 08x (Modular Broadband Connection Capability), a 3739B/C Broadband Set, two 3743E Millimeter-Wave s, and the necessary front and rear panel cables. A fully configured broadband system is shown below. The ME7838E Banded Millimeter-Wave system consists of an MS444B, MS44B VNA or MS447B with Option 08x, a 3739B/C Broadband Set, and two 3744E-EE, 3744E-EW, or two OML/VDI Millimeter-Wave s. v ME7838E BB/mm-Wave VNA System MS447B VNA, 3739B/C Set, 3743E s Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA Part Number: Revision: B Published: September 2014 Copyright 2014 Anritsu Company
2 Installing Rear Panel Cables This section focuses on installing cables when using a MS44xB VNA. Start the ME7838E assembly by placing the 3739B/C Broadband Set so you can access the rear panel for cable connection. Start the ME7838E assembly by placing the 3739B/C Broadband Set so you can access the rear panel for cable connections. Warning To avoid injury, use two or more people to lift the VNA to the top of the test set. Caution To avoid connector damage or inaccurate measurements, before making any connections, review the Connector Care Instruction Sheet, that was shipped with this system. Observe connector torque requirements where indicated in this guide. At the rear panels connect the cables as shown in Figure 1 and Table External I/O Ext In ALC 2 (With Option 031) Ext In ALC 1 (No Option 031) MS44xB VNA Ext Analog Out 1 9 Ext ALC Out Ext Alc Out Ext Analog In IF Outputs a 1 b a 2 b 2 External I/O Interface Cable Length WARNING No operator serviceable parts inside. Refer servicing to qualified personnel. CAUTION Do not operate with power cord ungrounded. ~ LINE INPUT 47-3 Hz VAC 10 VA Max Fuse 20V 2A T CAUTION 2 Standard Extended For continued fire protection replace only with specified type and rated fuse. 3739B/C Set 3 a1 IF b1 IF 3 3 a2 IF b2 IF Interface Ext Analog In 4 Cable Length Switch External I/O 3739C Only 12 Figure 1 Install Rear Panel Cables between 3739B/C Set and MS44xB VNA QSG-2 PN: Rev. B VectorStar ME7838E QSG
3 Table 1. ME78383E Cable Rear Panel Connections (MS44xB VNA) Part Number Index Description From VNA Location To 3739B/C Set Location MS44xB 1 VectorStar VNA 3739B or 3739C B or 3739C Broadband Set a1 IF a1 IF a ( cable bundle) 3 IF Interface Cables 4 External I/O Cable b b1 IF a2 IF b2 IF External I/O BNC (M-M) Cable Ext Analog Out BNC (M-M) Cable GPIB Cable (Not supplied) GPIB Cable (Not supplied) Ethernet Cable (Not supplied) USB Type B Cable (Not supplied) Cable for programmatic control Cable for programmatic control Cable for programmatic control Cable for programmatic control Ext In ALC 1 (without Option 031) Ext In ALC 2 (with Option 031) IEEE GPIB (for remote controlling ME7838) Dedicated GPIB (For controlling peripherals such as Power Meter) Ethernet Port USB Port (2) b1 IF a2 IF b2 IF External I/O Set EXT ANAG IN Set EXT ALC OUT 10 AC Power Cord c VNA AC Power Input NA 11 AC Power Cord c From 3739B/C Set AC Power Input 12 Interface Cable Length Switch (3739C only) a. Tighten each cable in this group using an 8 mm (/1 in) torque end wrench set to 0.9 N m (8 lbf in). b. Tighten the connector screws with a flat blade screwdriver. c. Do not yet connect to AC power cords to the AC source. NA NA NA NA VectorStar ME7838E QSG PN: Rev. B QSG-3
4 Installing Front Panel Cables Connect the front panel cables between the VNA and the 3739B/C Set, and between the Set and the millimeter-wave modules as shown below and as described in Table 2. Frequency Calibration Power Measurement Sweep Application Channel Avg System 1 Trace Response Display File Help Scale Marker Preset Standby Operate ALL PORTS: CAUTION +27 dbm MAX AVOID STATIC DISCHARGE ,,, Ref, and Pwr/Signal to Port 1 7,,, Ref, and Pwr/Signal to Port Port 1 to SRC (3743E only) Port 2 to SRC (3743E only) Example MS44xB VNA equipped with Option 01, 01, or 02 with included Front Panel Loops Note: The cables for Port 1 to SRC (key 8 to 9) and Port 2 to SRC (key 12 to13) are not used with mm-wave modules 3744E-EE, 3744E-EW, or 3744E-Rx. Figure 2 Front Panel Cables between 3739B/C Set, MS44xB VNA, and s 13 QSG-4 PN: Rev. B VectorStar ME7838E QSG
5 Table 2. ME7838E Cable Interconnect Part Numbers and Locations Part Number Index Description MS44xB 1 VectorStar VNA 3739B or 3739C B or 3739C Broadband Set 737-xx (See Note 1) 737-xx (See Note 1) 737-xx (See Note 1) xx a (See Note 2) 3 Semi-Rigid (KM-KM) Cable Tighten using an 8 mm (/1 in) torque end wrench set to 0.9 N m (8 lbf in). 4 Semi-Rigid (KM-KM) Cable Tighten using an 8 mm (/1 in) torque end wrench set to 0.9 N m (8 lbf in). Semi-Rigid (KM-KM) Cable Tighten using an 8 mm (/1 in) torque end wrench set to 0.9 N m (8 lbf in). -7, Cable Selection Notes Note 1 Note 2 mm-wave Interface Cables (for 3743E, 3744E-EE, 3744E-EW modules) Group of cables for each port OML Interface Cables Group of 4 cables for each port VDI Interface Cables Group of 4 cables for each port mm-wave Interface Cables (for 3744E-Rx modules) Group of 3 cables Connection From VNA VNA 1 VNA 2 Set,,, Ref, Set,,, Ref Set,,, Ref Set,, 8-9, Coaxial Phase Stable Cable VNA Cable Selection Cable Selection Description Standard (Non-Rack Mount) 3739B/C-001 Rack Mount Option Description 24 in, 1.8 mm M-F coaxial cable 3 in, 1.8 mm M-F coaxial cable Connection To Set Set 1 Set 2,,, Ref,,, IF, Ref IF Input, Input, Meas. IF, Ref IF,, mmwave module a. Cable 80-2xx Coaxial Phase Stable Cable is not included or required when using the 3744E-EE, 3744E-EW mm-wave modules, or the 3744E-Rx Receiver. VectorStar ME7838E QSG PN: Rev. B QSG-
6 Millimeter-Wave Connections Connect the 3739B/C Broadband Set Port-1 and Port-2 cables to the 3743E, 3744E-EE, 3744E-EW, or 3744E-Rx s as shown below, observing the correct torque limits for each connector. See Figure 3 and Table 3. Route the cable assemblies through the cable restraint. Note For ease of connection, the module can be removed from the bracket, then reinstalled after cables are secured. Observe torque instructions where indicated. Each module (except the 3744E-Rx) is characterized for absolute power for a specific VNA Serial Number and VNA Port as designated on the module port assignment label. Ensure the module matches the correct VNA and Set port. If an alternative 3743E mm-wave module is used there will be approximately 1 db of absolute power inaccuracy which can be corrected by performing a power calibration. For more detailed information on the modules including DUT Waveguide (WG) connection alignment and custom bracket mounting, refer to VectorStar Broadband/Banded Millimeter-Wave s Reference Manual REF 3743E 9 SRC A SRC (Not used) 10 Port Assignment 11 S/N REF (Not used) REF 3744E-EE 3744E-EW 3744E-Rx (Not used) SRC (Not used) Figure 3 Millimeter-Wave Connections Inverting a If necessary, a module can be turned over in the bracket to change the height of the W1 connector. To turn the module over: 1. Remove the six Knurled Head M2 8 mm Thumbscrews from the module. 2. Turn the module over. 3. Install the cable assembly. 4. Install the module into the bracket and then install the thumbscrews. QSG- PN: Rev. B VectorStar ME7838E QSG
7 Table 3. Millimeter-Wave Connections Cable P/N Index Description N/A 1 Millimeter-Wave in bracket N/A a or 78-3 b 3 4 W1-1 mm Connector (3743E, 3744E-Rx modules) Tighten using a torque end wrench and a plain end wrench mm Torque End Wrench set to 0.4 N m (4 lbf in). Recommended is Anritsu mm / 7 mm Open End Wrench. Recommended is Anritsu WR-10 or WR-12 Adapter - 1 mm connector (3744E-EE, 3744E-EW modules) Use Waveguide Adapter Toolkits ( , ). Tighten using a torque end wrench and a plain end wrench. mm Torque End Wrench set to 0.4 N m (4 lbf in). Recommended is Anritsu mm / 7 mm Open End Wrench. Recommended is Anritsu TEST - SSMC Connector (3743E, 3744E-EE, 3744E-EW, and 3744E-Rx modules) Tighten using a 4 mm (/32 in) torque end wrench set to less than 0.22 N m (2 lbf in). Recommended is Anritsu torque wrench. REF - SSMC Connector (3743E, 3744E-EE, and 3744E-EW modules) Tighten using a 4 mm (/32 in) torque end wrench set to less than 0.22 N m (2 lbf in). Recommended is Anritsu torque wrench. Latching Bi-Lobe Connector (3743E, 3744E-EE, 3744E-EW, 3744E-Rx) (Bi-Lobe is a registered trademark of Omnetics Corporation.) - K Connector (3743E, 3744E-EE, 3744E-EW, and 3744E-Rx modules) N/A 7 Power and I/O Cable Restraint c or c 8 SRC - V Connector (3743E module only) 78-1 a 9 - V Connector (3743E, 3744E-EE, and 3744E-EW modules) N/A 10 Factory Calibrated Port Assignment Label N/A 11 Serial Number Label a. 3743E, 3744E-EE, and 3744E-EW modules use cable assembly b. 3744E-Rx module uses cable assembly c. Cable 80-2xx Coaxial Phase Stable Cable is used only with the 3743E module. Millimeter-Wave Operating Environment The following notes should be observed when operating the 3743E and 3744E-xx Millimeter-Wave s: Thermal heat sinking similar to the supplied mounting brackets of the Millimeter-Wave should be considered in custom mounting applications. Each 3743E consumes a maximum of 12 watts. Each 3744E-EE and 3744E-EW consumes a maximum of 12 watts. Each 3744E-Rx consumes a maximum of 7 watts. The primary heat sinking path for the module is on the two external side surfaces used to mount to the support brackets. With the attached cable mounting brackets, the case temperature rise is approximately 1 C to 20 C above ambient. VectorStar ME7838E QSG PN: Rev. B QSG-7
8 OML/VDI Connections Connect the front panel cables between the 3739B/C Set, and the OML or VDI modules as shown in Figure 4, Figure, and Figure, and as described in Table 4, Table, and Table. Caution To avoid connector damage, observe torque requirements where indicated. Frequency Calibration Power Measurement Sweep Application Channel Avg System 1 Trace Response Display File Help Scale Marker Preset Standby Operate ALL PORTS: CAUTION +27 dbm MAX AVOID STATIC DISCHARGE Port 1,,, Ref To Left OML/VDI Port 2,,, Ref To Right OML/VDI Figure 4 Cable Connections between VNA, 3739B/C Set, and OML or VDI Frequency Extension s QSG-8 PN: Rev. B VectorStar ME7838E QSG
9 Table 4 ME7838E Cable Interconnect Part Numbers and Locations Part Number Index Description MS44xB 1 VectorStar VNA 3739B or 3739C B or 3739C Broadband Set 737-xx (See Note 1) 737-xx (See Note 1) 737-xx (See Note 1) Note 1-7, Semi-Rigid (KM-KM) Cable Tighten using an 8 mm (/1 in) torque end wrench set to 0.9 N m (8 lbf in). 4 Semi-Rigid (KM-KM) Cable Tighten using an 8 mm (/1 in) torque end wrench set to 0.9 N m (8 lbf in). Semi-Rigid (KM-KM) Cable Tighten using an 8 mm (/1 in) torque end wrench set to 0.9 N m (8 lbf in). OML Interface Cables Group of 4 cables for each port VDI Interface Cables Group of 4 cables for each port Cable Selection Notes Connection From VNA VNA 1 VNA 2 Set Ref Set Ref Connection To Set Set 1 Set 2 OML Ref IF Input Input IF VDI Input Ref. IF Meas. IF Input Cable Selection Description Standard (Non-Rack Mount) B/C-001 Rack Mount Option VectorStar ME7838E QSG PN: Rev. B QSG-9
10 From ME B/C Set Port 1 From ME B/C Set Port 2 1 Ref OML Frequency Extension s (Typical) Ref Ref IF Input DC Power Input IF Ref IF Input DC Power Input IF OML Power Supply OML Power Supply Figure VNA/ Set Cable Connections to OML s Table. OML Connections Cable P/N Index Description N/A 1 OML Ref IF - SMA Connector Input - SMA Connector Input - SMA Connector IF - SMA Connector N/A OML Power Supply QSG-10 PN: Rev. B VectorStar ME7838E QSG
11 From ME B/C Set Port 1 From ME B/C Set Port 2 Ref VDI VNA Extender s (Typical) Ref Input Ref. IF Power Meas. IF Input Input Ref. IF Power Meas. IF Input VDI Power Supply VDI Power Supply Figure VNA/ Set Cable Connections to VDI s Table. VDI Connections Cable P/N Index Description N/A 1 VDI 78-2 N/A a Input - K (2.92 mm) Connector Ref. IF - SMA Connector Meas. IF - SMA Connector Input- K (2.92 mm) Connector VDI Power Supply a. The VDI module connectors may differ slightly than on the illustration shown above. For example, depending on the model and date built, the power supply connector may be round instead of rectangular. VectorStar ME7838E QSG PN: Rev. B QSG-11
12 Anritsu utilizes recycled paper and environmentally conscious inks and toner. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA
PIM Master. Maintenance Manual
Maintenance Manual PIM Master MW8208A, MW8209A, MW8219A Passive InterModulation Analyzer MW8208A: 869 MHz to 894 MHz MW8209A: 925 MHz to 960 MHz MW8219A: 1930 MHz to 1930 MHz and 2110 MHz to 2155 MHz Anritsu
More informationMILLIMETER WAVE VNA MODULE BROCHURE
MILLIMETER WAVE VNA MODULE BROCHURE General Information OML, founded in 1991, is an expert at millimeter wave (mm-wave) measurements. Our successful foundation is built on mm-wave S-parameter measurements,
More informationAssembly Level Service Guide
Assembly Level Service Guide This guide describes how to service the Agilent 53150A, 53151A, and 53152A Microwave Frequency Counters. The information in this guide applies to instruments having the number
More informationInstallation Note. Agilent 89441A Option AYC Installation Kit
Installation Note Agilent 89441A Option AYC Installation Kit Part Number: 89441-90074 Printed in USA February 2002 Notice. The information contained in this document is subject to change without notice.
More informationInstruction Manual Model BlockUpconverter
Instruction Manual Model 2115-55 BlockUpconverter June 2009 - Rev. 0 MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More information6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2115-202 Upconverter November 2011, Rev. C MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More informationVector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.
Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change. Applications Academic/Education Design, development and manufacturing of passive and active
More informationInstallation Note. Option GHz Operation Upgrade Kit. For 8753E and 8753ES Network Analyzers. Applicable Upgrade Kit Model Number
Installation Note Option 006 6 GHz Operation Upgrade Kit For 8753E and 8753ES Network Analyzers Network Analyzer Model Number Applicable Upgrade Kit Model Number 8753E 8753EU Option 006 8753ES 8753ESU
More informationMAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams
MAXTECH, Inc. Technology for Communications BRC-1000 Series C-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic
More informationX-Band Redundant LNB Systems
X-Band Redundant LNB Systems BRX-1000 Series Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon
More informationInstruction Manual Model # Block Upconverter
Instruction Manual Model 2115-278# Block Upconverter August 2018, Rev. A MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary
More informationModel 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02
Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02 A fully integrated high-performance cross-correlation signal source analyzer from 5 MHz to 33+ GHz Key Features Complete broadband
More informationModular Block Converter Systems
Modular Block Converter Systems The Modular Block Converter System eliminates system downtime and maximizes ease of repair by providing fully modular systems for up conversion or down conversion. Critical
More informationPrecision TNC Coaxial Calibration Kit
User Guide Precision TNC Coaxial Calibration Kit DC to 18 GHz Models: 8650CK10/11 8650CK20/21 8650-511 (A) 2/15 User Guide Precision TNC Coaxial Calibration Kit DC to 18 GHz Models: 8650CK10/11 8650CK20/21
More informationAdvanced Test Equipment Rentals ATEC (2832)
E stablished 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar
More informationHigh Performance Outdoor Test Translators
Input Output LO Frequency Frequency Frequency Model (GHz) (GHz) (GHz) Number RF Transmit-Band to RF Receive-Band 5.85 6.425 3.625 4.2 2.225 DN-WS-6.1/3.9 5.85 6.65 3.4 4.2 2.45 DN-WS-6.25/3.8 6.725 7.025
More informationTest Systems. Typical JFW Systems. Matrix switches Programmable assemblies Switch assemblies Manual attenuator assemblies Power divider assemblies
Test Systems This section of our catalog showcases some standard JFW test systems. However, we understand that everyone s system requirements are unique. For this reason, we can design a system to suit
More information7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System
7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System A fully integrated high-performance cross-correlation signal source analyzer with platforms from 5MHz to 7GHz, 26GHz, and 40GHz Key
More informationR&S ZVA-Zxx Millimeter-Wave Converters Specifications
ZVA-Zxx_dat-sw_en_5214.2033.22_umschlag.indd 1 Data Sheet 13.00 Test & Measurement R&S ZVA-Zxx Millimeter-Wave Converters Specifications 28.01.2013 15:08:06 CONTENTS General information... 3 Definitions...
More informationMON8-1 1U 8-Channel Multi-Display Video Monitor
MON8-1 1U 8-Channel Multi-Display Video Monitor with Eight Backlit 1.75" LCD Displays, Eight CVBS Video Inputs, and Eight Loop-through Outputs Document P/N 821568 Rev-A User Manual CONTENTS Title and Contents...
More informationR&S ZVA110 Vector Network Analyzer Specifications
ZVA110_dat-sw_en_5214-4813-22_cover.indd 1 Data Sheet 04.00 Test & Measurement R&S ZVA110 Vector Network Analyzer Specifications 15.11.2013 14:42:28 CONTENTS Definitions... 3 Specifications... 4 Overview...
More informationModel /29S RF Splitter
Instruction Manual Model 1584-29/29S RF Splitter March 2013, Rev. 0 LNB VOLTAGE A B MODEL 1584 COMBINER CROSS TECHNOLOGIES INC. GND+DC ON Data, drawings, and other material contained herein are proprietary
More informationKu-Band Redundant LNB Systems
Ku-Band Redundant LNB Systems BRK-1000 Series Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon
More informationIntegre4. Audiophile integrated amplifier. v1.2
Owner s Manual Integre4 Audiophile integrated amplifier www.lab12.gr v1.2 Table of Contents It is yours Features Unpacking and Warnings Installation & Placement Front Panel Rear Panel Connections Remote
More informationFrequency. Range. HP 83751A/B: 2 GHz to 20 GHz HP 83752A/B: 10 MHz to 20 GHz. Standard 10 MHz timebase: f10 ppm
Frequency Range HP 83751A/B: 2 GHz to 20 GHz HP 83752A/B: 10 MHz to 20 GHz Timebase Stability Standard 10 MHz timebase: f10 ppm High stability timebase (Option le5): Accuracy = Calibration &Aging rate
More informationC-Band Redundant LNB Systems
C-Band Redundant LNB Systems BRC-1000 Series Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon
More informationFREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS
FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS Standard Configuration Vertical Mount Option FEATURES Antenna mount, weatherproof to IP-65 Automatic 5/10 MHz internal/external
More informationRSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable
RSSL1:1-KuXER Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System Outdoor Unit (ODU) Waveguide Switch & Status LNB 1 Coax cable Interface Terminal LNB 2 Indoor Unit Outdoor Unit Indoor
More informationSpectrum Master Models MS2723B and MS2724B
Maintenance Manual Spectrum Master Models MS2723B and MS2724B Handheld Spectrum Analyzer Anritsu Company 490 Jarvis Drive Morgan Hill, CA 95037-2809 USA Part Number: 10580-00165 Revision: D Published:
More informationInstruction Manual Model Block Up/Downconverter
Instruction Manual Model 4117-14 Block Up/Downconverter Weather Resistant Unit March 2017, Rev. J Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may
More informationJuniper Networks G10 CMTS
Juniper Networks G10 CMTS Pre-Installation Guide Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, CA 94089 USA 408-745-2000 www.juniper.net Part Number: 530-008003-01, Revision 1 Copyright
More informationKramer Electronics, Ltd. USER MANUAL. Model: VM Video Component Distributor
Kramer Electronics, Ltd. USER MANUAL Model: VM-1045 Video Component Distributor Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 1 3 Overview 3 4 Your VM-1045 Video Component Distributor
More informationFREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17
1/3 RACK-MOUNTED BLOCK CONVERTER Unit shown with Option 17 Unit shown without Option 17 FEATURES Automatic 5/10 MHz internal/external reference selection with a 0.1 Hz nominal bandwidth clean-up loop Gain
More informationBlackbird 1x4 HDMI Splitter for TV Walls
Blackbird 1x4 HDMI Splitter for TV Walls P/N 30917 User's Manual SAFETY WARNINGS AND GUIDELINES Please read this entire manual before using this device, paying extra attention to these safety warnings
More informationAmplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to
R Back to Amplifier Systems 1:1, Dual 1:1 and 1:2 Redundant Low-Noise The 1:1, dual 1:1 and 1:2 redundant lownoise amplifier (LNA) systems are designed to ensure continuous operation without disruption
More informationKeysight Technologies ad Waveform Generation & Analysis Testbed, Reference Solution
Keysight Technologies 802.11ad Waveform Generation & Analysis Testbed, Reference Solution Configuration Guide This configuration guide contains information to help you configure your 802.11ad Waveform
More informationKramer Electronics, Ltd.
Kramer Electronics, Ltd. Preliminary USER MANUAL Models: VM-5ARII, Video Audio Distribution Amplifier VM-20ARII, 1:20 Programmable Video Audio Distributor VM-1411, 1:10 Video/Audio Distributor Contents
More informationMG369xC Series Synthesized Signal Generators
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Operation Manual MG369xC Series Synthesized Signal Generators Anritsu Company 490 Jarvis Drive Morgan Hill, CA 95037-2809
More information1.2 GHz GS7000 Node RF Split Upgrade Application Note
1.2 GHz GS7000 Node RF Split Upgrade Application Note Overview Introduction Cable operators have experienced an exponential rise in the requirement for more reverse path bandwidth due to the popularity
More informationAgilent E5505A Phase Noise Measurement System
Agilent E5505A Phase Noise Measurement System Installation Guide NOTICE: In August 2014, Agilent Technologies former Test and Measurement business became Keysight Technologies. This document is provided
More informationTracVision R6DX Installation Guide
TracVision R6DX Installation Guide These instructions explain how to install the TracVision R6DX satellite TV antenna system on an RV or motor coach. Complete instructions on how to use the system are
More informationMENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2016-1250 Downconverter May 2009 Rev A F=2501.750 G=+25.0 MENU MODEL 2016 DOWNCONVERTER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained
More informationLM/TM-30xx, 31xx Series LCD Monitor User s Manual Rev. A0
LM/TM-30xx, 31xx Series LCD Monitor User s Manual Rev. A0 FCC NOTICE This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions
More informationLadyBug Technologies, LLC LB5908A True-RMS Power Sensor
LadyBug Technologies, LLC LB5908A True-RMS Power Sensor LB5908ARev8 LadyBug Technologies www.ladybug-tech.com Telephone: 707-546-1050 Page 1 LB5908A Data Sheet Key PowerSensor+ TM Specifications Frequency
More informationSpecifications MAV Series Matrix Switchers
Specifications MAV Series Matrix Switchers Video composite video and S-video models Routing MAV 44 Series... 4 x 4 matrix MAV 48 Series... 4 x 8 matrix MAV 62 Series... 6 x 2 matrix MAV 84 Series... 8
More informationKu-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN
BRK-1000 Series Ku-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon
More informationMultiple Band Outdoor Block Up- and Downconverters
Multiple Band Outdoor Block Up- and Downconverters Vertical Mount Option RF IF LO Frequency Frequency Frequency Model Band (GHz) (MHz) (GHz) Number Block Upconverters 1 12.75 13.25 0.95 1.45 11.8 UPB2-WS-13.625
More informationR&S ZVA-Zxx Millimeter-Wave Converters Specifications
R&S ZVA-Zxx Millimeter-Wave Converters Specifications Data Sheet Version 19.00 CONTENTS Definitions... 3 General information... 4 Specifications... 5 Test port... 5 Source input (RF IN)... 5 Local oscillator
More informationInstruction Manual Model Downconverter
Instruction Manual Model 2016-1351 Downconverter August 2010, Rev. A F=512 G=+0.0 MENU MODEL 2016 DOWNCONVERTER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained
More informationInstruction Manual Model Block Downconverter
Instruction Manual Model 3116-7890 Block Downconverter May 2016, Rev. 0 MENU 8.40-1.55 GHZ G=+10.0 REF AUTO-I MODEL 3116 DOWNCONVERTER CROSS TECHNOLOGIES INC. REMOTE ALARM POWER EXECUTE Data, drawings,
More informationL-BAND MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 3116-77#-1200 Block Downconverter February 2014, Rev. 0 MENU F = 7812.600 MHZ REF = INT L-BAND MONITOR MODEL 3116 DOWNCONVERTER CROSS TECHNOLOGIES INC. REMOTE ALARM POWER EXECUTE
More informationUSER MANUAL. Kramer Electronics, Ltd. Models:
Kramer Electronics, Ltd. USER MANUAL Models: VS-88A, 8 x 8 Balanced Audio Matrix Switcher VS-88V, 8 x 8 Video Matrix Switcher SD-7588V, 8 x 8 SDI Matrix Switcher Contents Contents 1 Introduction 1 2 Getting
More information8753E, 8753ET, and 8753ES Network Analyzer Option 1D5 High Stability Frequency Reference Upgrade Kit. Applicable Upgrade Kit Model Number
Installation Note 8753E, 8753ET, and 8753ES Network Analyzer Option 1D5 High Stability Frequency Reference Upgrade Kit Network Analyzer Model Number 8753E 8753ET 8753ES Applicable Upgrade Kit Model Number
More informationKramer Electronics, Ltd. USER MANUAL VM-20HD. Dual 1:10 HD/SD SDI Distribution Amplifier
Kramer Electronics, Ltd. USER MANUAL VM-20HD Dual 1:10 HD/SD SDI Distribution Amplifier Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Your VM-20HD Dual 1:10 HD/SD
More informationDish Diversity Switch
www.travel-vision.com Dish Diversity Switch INSTALLATION & USER S MANUAL Version 3.1 October 2013 PREFACE The information in this Installation and User s Manual is subject to change in order to improve
More informationWideband LNB: 2.4 GHz
Ka Multi-LO (Preset) Switchable LNB Wideband LNB: 2.4 Orbital Research Ltd 14239 Marine Drive, White Rock, BC. Canada V4B 1A9 Input bandwidth range 2.4 from to Multiple Input and Output ranges switchable
More informationMENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2584-31 Combiner May 2011, Rev. A RF MONITOR GAIN = -15 MENU MODEL 2584 COMBINER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained
More informationMONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 2099-10xx 10MHz Frequency Source April 2014, Rev. H MENU INTERNAL LEVEL = +10dBm MONITOR POWER 1 2 MODEL 2099 FREQUENCY SOURCE CROSS TECHNOLOGIES INC. ALARM OVEN REMOTE EXECUTE
More informationTraditional RF Splitter/Combiner and Directional Coupler User Manual
Traditional RF Splitter/Combiner and Directional Coupler User Manual Content Page INTRODUCTION... 1 Revision History... 2 Trademark Information... 2 Admonishments... 2 General Safety Precaution... 2 1
More informationRF Semiconductor Test AXRF RF Port Upgrade Kits
RF Semiconductor Test AXRF RF Port Upgrade Kits 2017 Datasheet The most important thing we build is trust Overview AXRF RF Port Upgrade Kits are designed to improve and extend the capability of an existing
More informationUSER MANUAL. VM-10xl Video Audio Distribution Amplifier MODEL: P/N: Rev 4
KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VM-10xl Video Audio Distribution Amplifier P/N: 2900-001042 Rev 4 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety
More informationAgilent Series Preselected Millimeter Mixers
Agilent 11974 Series Preselected Millimeter Mixers RF Sections Available in Four Bands from 26.5 to 75 GHz Data Sheet For the first time, preselected signal analysis is available to 75 GHz. With preselection,
More informationKeysight Technologies Antenna Test. Selection Guide
Keysight Technologies Antenna Test Selection Guide 1. Introduction Keysight Technologies, Inc. provides many of the components you need to make accurate antenna and radar cross-section (RCS) measurements.
More informationSIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO
SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO 18 GHz WIDE FREQUENCY RANGE: 0.5-18 GHz FEATURES High Dynamic Range Fast Switching Synthesizer with 10 Hz Tuning Resolution Excellent Phase Noise
More informationDANGER WARNING CAUTION
3EM20188 Issue 4 Maintenance Section TBD 2009 Chart 13 XMTR Output Level Calibration (No PA) PURPOSE Use this procedure to calibrate the UD-35() Transmitter output in radio configuration that is not equipped
More informationKa-Band Outdoor Block Upconverters and Low-Noise Block Downconverters
R Back to Block/Fixed Tuned Converters Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters Ka-BAND OUTDOOR BLOCK AND LOW-NOISE BLOCK Specifications Options Outline Drawings Phase Noise
More informationTraditional RF Splitter/Combiner and Directional Coupler User Manual
Traditional RF Splitter/Combiner and Directional Coupler User Manual Content Page INTRODUCTION... 1 Revision History... 2 Trademark Information... 2 Admonishments... 2 General Safety Precaution... 2 1
More informationNS-3 RF Noise Source Operation Manual
RF Noise Source Operation Manual Version 2.04 June 3, 2016 SPECIFICATIONS Frequency... Maximum output level... Output flatness... (at max output level) Impedance... Displayed level... Repeatability...
More informationTOOLS AND TEST EQUIPMENT REQUIRED
3EM20188 Issue 4 Maintenance Section TBD 2009 Chart 17 PA Output Level Calibration PURPOSE Use this procedure to calibrate the UD-51() Power Amplifier (PA) output in radio configuration that is equipped
More informationExtension kit for R&S Vector Network Analysers
NM300 Data Sheet September 2012 Extension kit for R&S Vector Network Analysers Characterisation of Nonlinear RF/HF Components in Time and Frequency domain Extension kit for R&S Vector Network Analysers
More informationMS2540 Current Loop Receiver with RS485 Communication
MS2540 Current Loop Receiver with RS485 Communication User Manual Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358 4202 Fax:
More informationCamera Control Unit 55D-BS VOLUME OPEN CABLE MIC OFF GND 2W CAMERA CABLE TALLY. Camera Adapter 55D-CA 9.39" 7.40" 5.2"
The Telemetrics Coax/Fiber Link is an affordable camera control system with increased operating distance. Using frequency multiplexing the following signals are transmitted over a single coaxial cable:
More informationPAM-1840 Preamplifier Operation Manual
PAM-1840 Preamplifier Operation Manual 1 TABLE OF CONTENTS INTRODUCTION 3 GENERAL INFORMATION 4 SPECIFICATIONS 4 OPERATING INSTRUCTIONS 5 MAINTENANCE 6 2 INTRODUCTION BEFORE APPLYING POWER Review this
More information6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 3116-7984-720-400# Downconverter January 2019, Rev. A MENU FC = 8175.000 G=+10.0 REF AUTO-I MODEL 3116 DOWNCONVERTER CROSS TECHNOLOGIES INC. REMOTE ALARM POWER EXECUTE Data, drawings,
More informationFREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS
MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS FEATURES Small weather resistant enclosure Automatic 5/10 MHz internal/external reference selection 10/100 Base-T Ethernet and RS-485/RS-422 remote control
More informationK Service Source. Apple High-Res Monochrome Monitor
K Service Source Apple High-Res Monochrome Monitor K Service Source Specifications Apple High-Resolution Monochrome Monitor Specifications Characteristics - 1 Characteristics Picture Tube 12-in. diagonal
More informationUSER GUIDE. DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version DM Engineering
USER GUIDE DM Engineering Multi Station Relay Adapter (MSRA and MSRA-RM) Version 1.35 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487 www.dmengineering.com Overview:
More informationACION 8000 Series. A8KFR1 1RU Forward Receiver
ACION 8000 Series A8KFR1 1RU Forward Receiver Overview The A8KFR1 is an advanced Forward Optical Receiver designed for HFC network to convert the optical signal to RF signal for distribution, with high
More informationInstruction Manual Model Up/Downconverter
Instruction Manual Model 2017-03 Up/Downconverter April 2016, Rev. M DOWNCONVERTER UPCONVERTER U F=1525 D F=1525 G=10.0 G=25.0 MENU MODEL 2017 UP/DOWNCONVERTER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER
More informationMULTIBAND 1/3 RACK-MOUNTED
BLOCK CONVERTER FEATURES Cover multiple ITU Ku-Band regions and other combinations Automatic 5/10 MHz internal/external reference selection with a 0.1 Hz nominal bandwidth clean-up loop RS-485/RS-422 and
More informationMON8-1/SDI 1U 8-Channel SDI Digital Multi-Display Video Monitor
MON8-1/SDI 1U 8-Channel SDI Digital Multi-Display Video Monitor (Document P/N 821626, Rev-A) with Eight Backlit 1.8" LCD Displays, Eight SDI Video Inputs, Eight SDI Re-Clocked Outputs, and Eight CVBS (Analog)
More informationInstruction Manual Model Block Upconverter
Instruction Manual Model 3115-73 Block Upconverter April 2013, Rev. 0 MENU 7.1-7.3GHZ G=+10.0 REF AUTO MODEL 3115 UPCONVERTER CROSS TECHNOLOGIES INC. REMOTE ALARM POWER EXECUTE Data, drawings, and other
More informationNVISION Compact Space and cost efficient utility routers
Space and cost efficient utility routers DESCRIPTION The NVISION Compact range is highly versatile, and ideally suited to utility routing applications. They are available for all core formats, including
More informationOPTICAL MEASURING INSTRUMENTS. MS9710C 600 to 1750 nm OPTICAL SPECTRUM ANALYZER GPIB. High Performance for DWDM Optical Communications
OPTICAL SPECTRUM ANALYZER 600 to 750 nm GPIB High Performance for DWDM Optical Communications The is a diffraction-grating spectrum analyzer for analyzing optical spectra in the 600 to 750 nm wavelength
More informationLINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1
LINK EXT40-4KECO 4K 40m HDMI Extender User Manual Version: V1.0.1 Important Safety Instructions 1. Do not expose this apparatus to rain, moisture, dripping or splashing and that no objects filled with
More informationModel P/03P Upconverters
Instruction Manual Model 2005-02P/03P Upconverters October 2013, Rev H 2005 TEST UPCONVERTER GHz 100MHz10MHz 1MHz C KU 70 140 IF IN GAIN DC POWER +DC IN +15V, 200 ma RF OUT DC ALARM LO IF FREQUENCY J1
More informationAssembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door
CHAPTER 8 Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door July 13, 2012, This document provides you with the procedures you perform to assemble and mount the
More informationVNA Master Model MS203xA
Maintenance Manual VNA Master Model MS203xA Vector Network Analyzer Anritsu Company 490 Jarvis Drive Morgan Hill, CA 95037-2809 USA P/N: 10580-00168 Revision: B Printed: December 2008 Copyright 2008 Anritsu
More informationOrbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60
Orbital 694XA Series Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts Wide range of Frequencies and Bandwidths How to order an Orbital 694XA Series Ka Ext Ref LNB Frequencies (GHz): LO Input Output
More information3G Multi-Rate Digital Video Optical Transmitter/Receiver/ Transceiver/Repeater. Installation and Operations. Manual
Manual DigiLink DLC103A Function module 3G Multi-Rate Digital Video Optical Transmitter/Receiver/ Transceiver/Repeater Installation and Operations Manual WWW.ARTEL.COM ii DLC103A Function Module Installation
More informationConverters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel
R Back to Multiband Converters 9700 Series Tri-Band Frequency Converters 9700 SERIES TRI-BAND FREQUENCY CONVERTERS The MITEQ frequency converters are designed for advanced satellite communication systems
More informationAgilent N5501A/N5502A Phase Noise Downconverter
Agilent N5501A/N5502A Phase Noise Downconverter Hardware Reference Second edition, May 2012 Agilent Technologies Notices Agilent Technologies, Inc. 2004-2012 No part of this manual may be reproduced in
More informationKD-MSVA4X4. 4 Inputs to 4 Outputs Component Video with Audio Matrix Switcher. Operating Instructions
KD-MSVA4X4 4 Inputs to 4 Outputs onent Video with Audio Matrix Switcher Operating Instructions Key Digital FatBoy Series KD-MSVA4x4 is a Video/Audio Matrix Switcher capable of separate switching of 4 onent
More informationAgilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers
Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers Technical Overview Focus on testing, not reconnecting! Maximize production throughput of cable-tv multiport
More informationHD1-LX HDMI & IR Extender
. HD1-LX HDMI & IR Extender Quick Reference & Setup Guide Magenta Research 128 Litchfield Road, New Milford, CT 06776 USA (860) 210-0546 FAX (860) 210-1758 www.magenta-research.com MAGENTA HD1-LX HDMI
More informationLEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free
Instruction Manual Model 1200-75 Amplifier August 2012, Rev. A LEVEL ADJUST POWER MODEL 1200 AMPLIFIER CROSS TECHNOLOGIES, INC. Data, drawings, and other material contained herein are proprietary to Cross
More informationMAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide
MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK Model MX3257HD Description The rack-mountable MX3257HD fiber optic video multiplexer is ideal for transmitting 1 channel of video, 2 channels
More informationSIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz
SIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER FREQUENCY RANGE: 20 to 3000 MHz High Dynamic Range Enables the End User to Reject Blocking Signals Often Undetected by Less Sensitive Tuners High Dynamic Range
More informationPXI MICROWAVE IF DOWNCONVERTER MODULE
The PXI-1440 IF Downconverter Module is a PXI 3U, 1-slot module that facilitates additional frequency translations to lower intermediate frequencies (IF) when high-dynamic range digitization is required.
More informationSATCOM FIBER OPTIC PRODUCTS
INDOOR APPLICATIONS ONE THIRD RACK SATCOM FIBER OPTIC PRODUCTS CARD CAGE RACK OUTDOOR APPLICATIONS DC-POWERED L-BAND C-BAND LNA TABLE OF CONTENTS INDOOR EQUIPMENT Page One third rack links 2 One third
More information