C A R G O C O N T R O L. By Fritz Dahlin

Size: px
Start display at page:

Download "C A R G O C O N T R O L. By Fritz Dahlin"

Transcription

1 C A R G O C O N T R O L By Fritz Dahlin What Our TESTING & RESEARCH Shows Note: Please be aware that this testing was done with new product under controlled conditions. NO product should EVER be used above its WORK LOAD LIMIT. Minimum break strengths should NEVER be used to determine the suitably of a product. Failure to follow these warnings may result in property damage, personal injury or death. The intention of this article is to show the effect of improper loading over a corner has on the product. One of our salesmen called me back to his desk the other day. He said, So and so sent me a picture of a strap that broke. Can you take a look at it and see what you think? I said, Sure. Pull it up. As soon as the picture opened, I said, It was cut. He asked, How do you know? Easy. I said. Those hundreds of fibers did not all break at the same time and same place for no reason. Now, as much as I d like to say I thought that up all by myself, I can t. Credit goes to Michael Gelskey, a fellow member (and past president) of the Web Sling Tie Down Association. One of my jobs at B/A Products Co. is to attend the semiannual WSTDA meetings. We talk about exciting stuff like the recommended pin diameter for testing 12 slings, what the minimum corner radius round slings 28 Tow Professional Volume 3 Issue 3

2 should be loaded over, and my personal favorite, whether poly and nylon slings should be washed or not. Mike gave a presentation about a sling his company made that failed and resulted in a fatality. As he told the story, there was a picture of the sling on the screen. The sling had been laid over the angle iron arm of a transmission tower. The sling was laid over the arm of the tower, unprotected, and loaded repeatedly. The arm of the tower contacted the same place on the sling each time it was loaded, until it wore through (cut) the sling with catastrophic results. To those of us in the web industry, the cause was obvious. To many outside the web industry or those who may not have been trained on proper use and inspection of web slings, it may not be. And I won t limit that statement to web. Wire rope and chain, when used in a manner that they are not designed for, or are not protected from damage, will fail. They will also leave telltale signs. The goal of this article is to make you aware of the damage that a seemingly innocent corner can cause, the signs that a piece of web or wire rope was damaged or cut, and some basic inspections that must be performed on a regular basis. TEST SET UP AND PARTICULARS I wanted to recreate some things that I see on a fairly regular basis. Another of my jobs at B/A is to do the testing of inbound materials, as well as inspecting returns to try and determine cause of failure, so I have not only seen a lot of broken things, but I have broken my share of them, as well. I decided to try to replicate what happens when a piece of wire rope or web is pulled over a 90 degree corner. To set up the tests, I cut several lengths of 2 x 2 x 3/16 angle iron to fit over the top edge of the carriage of one of our test beds. I then figured a way to secure a piece of tie down web, wire rope, 2 2 ply sling and a V strap leg so it was pulled over the outside corner of the angle iron. Test set up for tie down strap strap control sample. Let s get to the testing. For each item, I loaded 3 samples over the angle to get a good average break, and did either a straight pull test or used test results from my files for each product to use as a control sample. First up was a cluster tie down strap, rated at a 4000 Lb. Work Load Limit, 12,000 Lb. minimum break strength. Keep in mind that the minimum break strength (MBS) should NEVER be used as a rating or for selecting a tie-down, strap chain or wire rope. The control sample broke at 11,964 Lbs. As you can see from the photo, the webbing shredded at the stitching. The straps were set up with the free end of the strap wound up in a ratchet, and the mini J of the cluster hooked to the underside of the test bed. The samples that were pulled over the angle were marked where the web contacted the corner, and two inches on either side of the angle. Force was applied until the samples failed. As the force increased, the web stretched and the contact point with the angle moved about two inches. Failures occurred at 7519, 7383 and 7181 Lbs., all where the web contacted the angle strap pulled over angle iron Volume 3 Issue 3 Tow Professional 29

3 Notice that the strap pulled over the corner is cut cleanly across the width of the web, and all or nearly all the fibers are the same length, with minimal fraying. Compare these with the control sample. This is the indication that the webbing was cut. The average failure was at 7361 Lbs., for a 37% reduction in MBS. Look at it another way: Work Load Limit is based on a ratio of the MBS. In the case of this strap, the 4000 Lb. WLL is a 3 to 1 ratio of the 12,000 Lb. MBS. Since our MBS over a piece of angle iron is 7361 Lbs., divide that by 3, your WLL is now 2453 Lbs. Now, I m not suggesting that the straps be rerated because it is being pulled over a corner, but the reality is if the strap is pulled around a corner, the strap will fail at a lower load. Let s put a 2 two ply sling to the same test. WSTDA ratings for this sling are a WLL of 6200 Lbs. in a vertical hitch, with a 5 to 1 design factor for a MBS of 32,000 Lbs. My control sample failed at 32,191Lbs., the webbing again shredded at the stitching. 2 sling control sample. Graph for 2 sling control sample. The test samples were installed in the test bed with one eye over the hook, under the carriage, over the angle and to the second test bed hook. The samples were marked the same way as the cluster strap, and force applied until failure. As force increased, the strap stretched until the 2 inch mark was adjacent to the corner. During one of the test pulls, the test bed ran out of stroke. (The ram was fully retracted before failure occurred. I did the testing over several days and this sample was hooked to the test bed differently.) I took the strap out of the test bed to reset the test and noticed the damage to the strap where it had been in contact with the corner of the angle. I ll show you that damage a little later. All three samples failed at the angle, with an average failure of 13,023 Lbs, less than half of the straps MBS. Using the same logic as the cluster tie down strap, the WLL has effectively been reduced from 6200 Lbs, to 2604 Lbs. Once again, I am not suggesting the strap be rerated; I am trying to illustrate how damaging loading over a corner can be. As with the cluster strap, the fibers at the cut are relatively even with minimal fraying. 2 inch 2 ply slings after being pulled over angle. Arrow shows direction strap was being pulled. 30 Tow Professional Volume 3 Issue 3

4 C A R G O C O N T R O L Let s switch from web to wire rope for the next test. For this round, I tested 3/8 EIPS IWRC (Extra Improved Plow Steel Independent Wire Rope Center) made into 10 foot long sections with thimbled eyes at each end. The samples were attached to one hook of the test bed, laid over the angle on the carriage, then run under the carriage and tied off to a cross member of the tester. The wire rope test set up. This resulted in the sample contacting the carriage in two places. In all three tests, the end of the wire rope attached to the movable hook of the test bed failed (the end having force applied), including one test that I inadvertently ran under the carriage to the hook (it failed on the edge of the carriage, not the angle). The control sample failed at 16,397 Lbs., at one of the swages. Graph of 3/8 steel core wire rope control sample. Volume 3 Issue 3 Tow Professional 31

5 The three samples pulled over the angle failed at an average of 9503 Lbs., a reduction of 42% from the control sample. In each case, the wire rope failed where it was contacting the corner. Four of the six strands failed on two of the samples, and two of six failed on the third. I stopped each test once the failure occurred. If I had continued to apply force, the remaining strands would have failed, but the load would have been lower that the first failure point. Detail of failure over angle. Damage to the angle is from previous wire rope tests. It should also be noted that the wire rope sample contacted the carriage on the test bed in two places, and the point where failure did not occur was damaged, as well. Damage to three samples pulled over angle. So far, the testing has gone pretty much as I expected. All of the samples failed where they contacted the corner of the angle iron at an average of 46% below their Minimum Break Strength, due to the damage the corner inflicted. Next, I tested individual V strap legs, and things get very interesting. My goal was to recreate the damage you see here: Take a look at the bottom leg. Notice how the fibers are smooth and even for the first two inches of width from the bottom. They compare very closely to the cut tie down strap and 2 inch sling shown earlier, but also take a look at the top leg. Notice the mark that mirrors the cut on the lower leg? Most likely both legs were riding against a cross V strap returned member or control arms. by customer for To simplify the testing, I had single legs of our V inspection. straps made up. Our V straps have a 4700 Lbs. Work Load Limit. I set up the V legs so the last 3 inches or so of the strap was contacting the corner of the angle, and applied force. The first two legs I pulled got fairly high readings: 13,181 Lb and 13,272 Lb. On the third leg, I moved the contact point slightly and got 15,712 Lbs. Samples 1 and 3 were cut at the contact point with the corner, sample 2 was a cut on either side of the leg at the contact point, and then the oblong pulled through the remaining center inch or so of the eye. The control sample failed at 16,032 Lb., the oblong elongated significantly and cut through the web at the end of the eye. Three V strap legs after being pulled over the corner of the angle. 32 Tow Professional Volume 3 Issue 3

6 C A R G O C O N T R O L V strap test set up. V strap control strap after test. The average reduction in break from the control sample was 14%. Why is the reduction in MBS on the V strap leg only 14%, when the average reduction of the other parts is 46%? The V strap legs have a Cordura pad sewn over the eye at the hook end. In all 3 tests, the Cordura pad was at the angle or pulled to the angle when the leg stretched. That cordura pad made the difference. But the control sample looks just like the other legs, the fibers are all the same length with minimal fraying. What gives? I m glad you have been paying attention. It s time to talk about some of the signs of damage. Let s start with the V strap legs. In reality, the control sample was cut, as well. Take a look at the oblong links in the photo of the test samples then the oblong link in the control sample. The test samples elongated very little, which shows that they were not getting the 14,000 Lbs. or so average it took to break the sample. The oblong of the control sample elongated considerably, indicating it was seeing the full load applied to the sample. As it elongated, the contact point with the eye of the web became smaller and smaller, until that point could no longer support the load and the web failed. This is a good example of why it is important to check the entire assembly during routine inspections or after a failure. The example of the green V strap shown earlier backs up this point. The side that did not fail shows that there was contact with an object. WIRE ROPE: The samples were pulled over two 90 degree angles; one end was tied off to the frame of the tester, the other end tied off to the ram of the tester. Failure occurred at the 90 degree angle closest to the ram (even on the sample I ran incorrectly). Where the wire rope contacted the second angle, there was damage, as well. This damage creates a weak spot that can fail when a load is applied later. Also take a look at the photo of the break in the wire rope while it is over the angle. The ends of the individual strands show two different configurations. Some are flat, like a chisel or knife blade. This is an indication of mechanical damage, such as crushing or being bent around a corner. Others show a cup and cone shape. When an individual wire is overloaded, it will stretch. Volume 3 Issue 3 Tow Professional 33

7 When it cannot stretch any more, the wire breaks. One side of a break looks like a cone, the opposite side like a cup. Overloading will also leave signs. The thimble will stretch at roughly twice the Work Load Limit of the wire rope. WEB SLING: I mentioned that during the testing I had to reset the strap and noticed damage. The strap had been pulled to 12,109 Lbs. Here s the damage: Damage to strap pulled over corner without failure. When the strap was reset and pulled again, it failed at 12,110 Lb., 1 pound over the previous pull. Do you think the damage had something to do with that? Compare the previous photo with the photo of the strap after it was pulled the second time. It failed in the same place. Still not convinced? That strap broke lower that the other two by almost 1000 Lbs. Once again, previous damage can and will weaken the assembly. Top: thimble that has not been subjected to overload. Bottom: Thimble used in break test. Same strap from previous photo, after being pulled over angle to failure. Also notice the wear and marks at the letter S. In the test set up, the sling contacted the carriage of the test bed in two places. While most of the load applied to the strap was concentrated at the angle where the strap ripped, there was enough force at the second corner to create additional damage. All of the 2 inch slings and the cluster tie downs exhibit this damage. Breaking strengths are shown for comparison only and shall NOT to be used as criteria for service or design purposes. NEVER exceed the products assigned WORK LOAD LIMIT. So, how can these failures be prevented? What kind of inspections should you be doing? And what about chain? I m going to cover those subjects next month. One thing before I go: In the opening, I talked about going to WSTDA meetings and some of the topics of discussion. Please don t get the wrong idea; I really do enjoy the meetings. And yes, those are really topics we discuss. The answers, in case you are interested: 12 sling testing pin diameter 4.5, span 13 ; minimum corner radius for round sling, depends on the sling, a yellow round sling is 5/16, and no, slings should not be machine washed (or washed at all). TOW Fritz Dahlin is vice president of B/A Products Co., 34 Tow Professional Volume 3 Issue 3

Aerial Cable Installation Best Practices

Aerial Cable Installation Best Practices Aerial Cable Installation Best Practices Panduit Corp. 2007 BEST PRACTICES Table of Contents 1.0 General... 3 2.0 Introduction... 3 3.0 Precautions... 4 4.0 Pre-survey... 5 5.0 Materials and Equipment...

More information

MY-HITE ADJUSTABLE TABLE

MY-HITE ADJUSTABLE TABLE MY-HITE ADJUSTABLE TABLE Corner T Leg Base Model Number : FCNAHBT Please Read Instructions Before Use ASSEMBLY INSTRUCTIONS ALL WORKSTYLES WELCOME Thank you for choosing Friant. We appreciate the trust

More information

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation Underground Installation M P - 1012 Issue #3 March 2011 DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES The practices contained

More information

White Paper. Discone Antenna Design

White Paper. Discone Antenna Design White Paper Discone Antenna Design Written by Bill Pretty Highpoint Security Technologies Property of Highpoint Security Technologies Inc The user of this document may use the contents to recreate the

More information

Category 3 Non-Cab Operated Crane Safety Rev-04 Instructor Guide Revisions

Category 3 Non-Cab Operated Crane Safety Rev-04 Instructor Guide Revisions Category 3 Non-Cab Operated Crane Safety Rev-04 Instructor Guide Revisions Cover Sheet 1. Modified the course number to include the current revision NCC-C3CS-04 Introduction Module 2. In the Welcome topic,

More information

MAXIMUM REACH ENTERPRISES 1853 Wellington Court Henderson, NV Ph: cox.net 20 December 2018

MAXIMUM REACH ENTERPRISES 1853 Wellington Court Henderson, NV Ph: cox.net   20 December 2018 MAXIMUM REACH ENTERPRISES 1853 Wellington Court Henderson, NV 89014 Ph: 702 547 1564 kent.goodman @ cox.net www.maximumreach.com 20 December 2018 BUSINESS CARDS In my early years as a rigging engineer,

More information

WALKING A TIGHT ROPE

WALKING A TIGHT ROPE MAXIMUM REACH ENTERPRISES 1853 Wellington Court Henderson, NV 89014 Ph: 702 547 1564 kent.goodman @ cox.net www.maximumreach.com 07 August 2013 WALKING A TIGHT ROPE Last month, I saw a video where Nik

More information

AT-AUTO (tm) QRO Keyline Upgrade Kit Installation Manual

AT-AUTO (tm) QRO Keyline Upgrade Kit Installation Manual AT-AUTO (tm) QRO Keyline Upgrade Kit Installation Manual P.O. Box 341543 Beavercreek, Ohio 45434 5 September, 2015 Copyright 2015 ii Contents 1 Introduction 2 1.1 General Description and Purpose........................

More information

Section 8 FIBERLIGN Hardware for Aerial FTTP Applications

Section 8 FIBERLIGN Hardware for Aerial FTTP Applications Section FIBERLIGN Hardware for Aerial FTTP Applications Table of Contents Page FIBERLIGN Products for ADSS Applications FIBERLIGN ADSS Drop Cable Dead-end...-2 FIBERLIGN Midspan Drop...-5 FIBERLIGN LITE

More information

Triax TechInfo. Installing and pulling Fibre Optic cables

Triax TechInfo. Installing and pulling Fibre Optic cables Installation methods for both wire cables and Fibre Optical cables are similar. Fibre cable can be pulled with much greater force than copper wire if you pull it correctly. Just remember these rules: 1)

More information

SUPERFLEX CABLE. What is Superflex Cable? Why make cable this way? Where Superflex Cable originated

SUPERFLEX CABLE. What is Superflex Cable? Why make cable this way? Where Superflex Cable originated SUPERFLEX CABLE What is Superflex Cable? Why make cable this way? Where Superflex Cable originated How it is made Other Advantages of this type of cable Interesting things about it Usage in present rigging

More information

VersaCap Lighting System

VersaCap Lighting System VersaCap Lighting System Installation Instructions For Single Universe Lighting Systems Manual Version: V1.1 DFX 465 Taunton Avenue, Suite 108, West Berlin, NJ 08091 800-555-5280 www.dfxsoundvision.com

More information

Cable System Installation Guide

Cable System Installation Guide Overview Cable System Installation Guide 5/19/2008 Our recommended approach for the installation of your Circle Graphics Cable Systems on the panels in your market is to install the fixed hardware (namely

More information

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables revision history Issue Date Reason for Change Related literature SRP-004-136 Accessing All-Dielectric DX Armored Fiber Optic Cables Admonishments 1. General This procedure provides instructions for installing

More information

Installation Guide OvalSox TM Cable

Installation Guide OvalSox TM Cable Installation Guide OvalSox TM Cable Thank you for selecting a DuctSox System. This guide will be helpful for the installation of an OvalSox Cable System. Sections of fabric will be labeled, assembled,

More information

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS (440)

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS (440) GUY-GRIP Dead-end NOMENCLATURE Identification Tape Color Code and Cross-Over Marks* (A) (B) Short Leg Pitch Cabled Loop Cross-over Marks*: (A) Indicate starting point for application on smaller diameter

More information

UNSIGNED HARDCOPY NOT CONTROLLED

UNSIGNED HARDCOPY NOT CONTROLLED SUBJECT: APPROVED BY STATUS PURPOSE AFFECTED FUNCTIONS REFERENCES Cable and Harness Making Manager, Hardware Engineering Maintenance Revision Establishes requirements for the fabrication and inspection

More information

Lashing Rods NOMENCLATURE GENERAL RECOMMENDATIONS. C = D x m = D x.666. m = D x.414. m = D x.483. C = (D + m) x.850. Length.

Lashing Rods NOMENCLATURE GENERAL RECOMMENDATIONS. C = D x m = D x.666. m = D x.414. m = D x.483. C = (D + m) x.850. Length. Lashing s NOMENCLATURE Deburred and : Assist in identification of size, corresponding to tabular information appearing on price pages. diameter: Identifies size of metal wire, corresponding to tabular

More information

nroads Fleet Full Size Lightbar Mid-Size Lightbar Mini Lightbar Beacons Accessories

nroads Fleet Full Size Lightbar Mid-Size Lightbar Mini Lightbar Beacons Accessories 2 0 1 8 P R O D U C T S C A T A L O G nroads Fleet Full Size Lightbar Mid-Size Lightbar Mini Lightbar Beacons Accessories Snow plows, pickup trucks, utility vehicles, refuse trucks, paving equipment and

More information

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA Operating Manual Automated Gear Apollo Design Technology, Inc. 4130 Fourier Drive Fort Wayne, IN 46818 USA PH: +01(260)497-9191 FX: +01(260)497-9192 www.apollodesign.net 11-25-09 5-6 POWERING UP THE RIGHT

More information

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA NOTE: These installation instructions have been written for

More information

CHAPTER 14 WIRING SIGNALS AND LIGHTING FIELD GUIDE Wiring Requirements WIRING

CHAPTER 14 WIRING SIGNALS AND LIGHTING FIELD GUIDE Wiring Requirements WIRING WIRING CHAPTER 14 WIRING The installation of all wiring, including electrical cables and conductors, must conform to the National Electrical Code (NEC). The Code represents the minimum required standard.

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 102 2010 Cable Retention Force Testing of Trunk & Distribution Connectors NOTICE The Society of Cable Telecommunications

More information

PRJTPFL inch PRJTPFL inch PRJTPFL inch. Fixed Wall Mount Projector Screen. Universal Home/Office Projector Viewing Display

PRJTPFL inch PRJTPFL inch PRJTPFL inch. Fixed Wall Mount Projector Screen. Universal Home/Office Projector Viewing Display PRJTPFL102-100 - inch PRJTPFL112-110 - inch PRJTPFL122-120 - inch Fixed Wall Mount Projector Screen Universal Home/Office Projector Viewing Display Be sure to read this manual before use so you will know

More information

UltraTwist. Product Description. Instruction Guide

UltraTwist. Product Description. Instruction Guide UltraTwist Instruction Guide English 7EN111103-01 2009-07-06 Applies to the following models: UltraTwist Slim Prod. No. 3126045 UltraTwist Wide Prod. No. 3126047 UltraTwist Slim UltraTwist Wide Product

More information

Multi-Media Installation Guide

Multi-Media Installation Guide Multi-Media Installation Guide Coaxial Page 2 Data Plug Page 7 Data Jack Page 10 Telephone Page 13 Splicing Page 15 Cable Types Cable Types Two basic types of cable are used in multimedia installations.

More information

OCC Installation Figure 8 Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

OCC Installation Figure 8 Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE Installation Figure 8 Guidelines Excerpt from Optical Corporation s INSTALLATION GUIDE Figure 8 A figure 8 fiber optic cable design incorporates a steel or dielectric messenger into the fiber optic cable

More information

Obtained from Omarshauntedtrail.com

Obtained from Omarshauntedtrail.com http://www.cindybob.com/halloween/ledlighting/ledspotlights/ Introduction In our 2005 haunt providing 120V AC power to the various lights and props requiring it became a fairly large problem. Extension

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 315 August 2000 SERIES 2000 DWDI BACKWARD INCLINED FANS TYPE BAB Series 2000 BAB DWDI Backward Inclined Fans This bulletin features our new BAB Series 2000 DWDI (double

More information

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz ASSEMBLY AND INSTALLATION A449-6S 70 CENTIMETER FM YAGI ANTENNA 440-450 MHz COMMUNICATIONS ANTENNAS 951425 (7/93) WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT IN

More information

TUBE AERATION NEXT GENERATION 9000 & INSTALLATION MANUAL

TUBE AERATION NEXT GENERATION 9000 & INSTALLATION MANUAL TUBE AERATION INSTALLATION MANUAL Read this manual before using product. Failure to follow instructions and safety precautions can result in serious injury, death, or property damage. Keep manual for future

More information

DLP ANTENNA INSTRUCTION MANUAL. Dielectric LLC 22 Tower Road Raymond, Maine Phone:

DLP ANTENNA INSTRUCTION MANUAL. Dielectric LLC 22 Tower Road Raymond, Maine Phone: DLP ANTENNA INSTRUCTION MANUAL Dielectric LLC 22 Tower Road Raymond, Maine 04071 Phone: 800-341-9678 TABLE OF CONTENTS Section Title Page Warnings 1 Return Policy. 1 Factory Tests... 1 Antenna Description....

More information

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE Revision No.:01 Date: 07.10.06 SPECIFICATION OF 96F SM LOOSE TUBE, DRY CORE MINI CABLE PART NO.:D-96/SM/MTY(F)-MFN-O6.3 Checked By: Pavan Maheshwari Process Associate Design & Development Team Approved

More information

TECHNICAL BULLETIN. Ref. No. P (Repl P-03-11)

TECHNICAL BULLETIN. Ref. No. P (Repl P-03-11) 0 TECHNICAL BULLETIN August 2006 Ref. No. P-06-01 (Repl P-03-11) Guidelines for Selection of Replacement Tires --Including Substitute Tire Sizes-- With Important Safety Information To ensure the same performance

More information

Category 2 and Cab-Operated Category 3 Crane Safety Rev03 Instructor Guide Revisions

Category 2 and Cab-Operated Category 3 Crane Safety Rev03 Instructor Guide Revisions Category 2 and Cab-Operated Category 3 Crane Safety Rev03 Instructor Guide Revisions Instructor Information 1. Modified the wording and information in the Instructor Information section Introduction Module

More information

K Service Source. Apple High-Res Monochrome Monitor

K Service Source. Apple High-Res Monochrome Monitor K Service Source Apple High-Res Monochrome Monitor K Service Source Specifications Apple High-Resolution Monochrome Monitor Specifications Characteristics - 1 Characteristics Picture Tube 12-in. diagonal

More information

CARLITE grain orien TEd ELECTRICAL STEELS

CARLITE grain orien TEd ELECTRICAL STEELS CARLITE grain ORIENTED ELECTRICAL STEELS M-3 M-4 M-5 M-6 Product d ata Bulletin Applications Potential AK Steel Oriented Electrical Steels are used most effectively in transformer cores having wound or

More information

Part names (continued) Remote control

Part names (continued) Remote control Introduction Part names (continued) Remote control (1) STANDBY ( 25) (1) (2) ON ( 25) (3) (3) ID - 1 / 2 / 3 / 4 s ( 18) (4) (4) COMPUTER 1 ( 27) (7) (5) COMPUTER 2 * (8) (6) COMPUTER 3 * (10) (13) (7)

More information

K Service Source. Apple High-Res Monochrome Monitor

K Service Source. Apple High-Res Monochrome Monitor K Service Source Apple High-Res Monochrome Monitor K Service Source Specifications Apple High-Resolution Monochrome Monitor Specifications Characteristics - 1 Characteristics Picture Tube 12-in. diagonal

More information

HCS - HES Cabling Systems

HCS - HES Cabling Systems HCS - HES Cabling Systems Installation Manual for HCS High-Capacity Fiber-Optic Rack-Mount Cabinets Be sure to read and completely understand this procedure before applying product. Be sure to select the

More information

TECHNICAL SPECIFICATIONS: STICKS STONES BROKEN BONES Company: Bunk Puppets, contact :Jeff Achtem,

TECHNICAL SPECIFICATIONS: STICKS STONES BROKEN BONES Company: Bunk Puppets, contact :Jeff Achtem, TECHNICAL SPECIFICATIONS: STICKS STONES BROKEN BONES Company: Bunk Puppets, contact :Jeff Achtem, jachtem@yahoo.com General Specifications Sticks Stones, Broken Bones is a flexible show adaptable for large

More information

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98) Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98) 1. Splicing specifications are provided by Mediacom, but due to resplice conditions, many locations become

More information

Cable Retention Force Testing of Trunk & Distribution Connectors

Cable Retention Force Testing of Trunk & Distribution Connectors ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 102 2016 Cable Retention Force Testing of Trunk & Distribution Connectors NOTICE The Society of Cable Telecommunications

More information

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation Underground Installation Install 22 June 23, 2017 DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES The practices contained herein

More information

FOSC 450 C6 and D6 Closures

FOSC 450 C6 and D6 Closures FOSC 450 C6 and D6 Closures I N S T A L L A T I O N I N S T R U C T I O N Fiber Optic Splice Closure 1. General Product Information The FOSC 450 C6 and D6 fiber optic splice closures use compressed gel

More information

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE Revision No.:00 Date: 08.03.2010 SPECIFICATION OF 192F SM LOOSE TUBE, DRY CORE MINI CABLE PART NO.:D-192/SM/MTY(F)-MFN-O9.1 Checked By: Pavan Maheshwari Process Associate Design & Development Team Approved

More information

A CENTIMETER FM YAGI ANTENNA MHz

A CENTIMETER FM YAGI ANTENNA MHz ASSEMBLY AND INSTALLATION A449-70 CENTIMETER FM YAGI ANTENNA 440-450 MHz COMMUNICATIONS ANTENNAS 951424 (10/91) WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT IN DEATH

More information

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit 2178 Fiber Optic Splice Case and 2181 Cable Addition Kit Instructions January 1994 Issue 1, 34-7029-6387-6 1 2 Contents: 1.0 General... 4 2.0 Specifications... 4 3.0 Kit Contents... 5 SECTION 1: 2178 Splice

More information

WARNING VGTWC VGF-1. Model No. Galvanized Steel Thimble and Wire Rope Cable Termination Kit

WARNING VGTWC VGF-1. Model No. Galvanized Steel Thimble and Wire Rope Cable Termination Kit VGTWC WARNING All persons using this equipment must read, understand and follow all instructions. In addition, all instructions provided with the cable and/or lifeline system with which this equipment

More information

SEP Bright Pi v1.0 Assembly Instructions

SEP Bright Pi v1.0 Assembly Instructions SEP Bright Pi v1.0 Assembly Instructions When you purchased your Bright Pi v1.0 kit, you should have received an anti-static bag with some components in it which will require soldering together in order

More information

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum: User manual Website: http://www.we-con.com.cn/en Technical Support: support@we-con.com.cn Skype: fcwkkj Phone: 86-591-87868869 QQ Group: 465230233 Technical forum: http://wecon.freeforums.net/ 1. Introduction

More information

Aerospace Fiber Optics

Aerospace Fiber Optics Aerospace Fiber Optics AFO 101, Session 2 Fiber Optic Assembly Everett Community College. All rights reserved. 1 Session Learning Objectives After completing this session you should be able to: Work safely

More information

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide GB05-7 Peak Atlas IT RJ45 Network Cable Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001/2013 In the interests of development, information

More information

NDT Supply.com P.O. BOX 7350 Shawnee Mission, KS USA

NDT Supply.com P.O. BOX 7350 Shawnee Mission, KS USA NDT Technologies, Inc. Wire Rope Inspection Using proven MFL Technology. NDT Technologies has over 30 years of experience dedicated to developing and improving Wire Rope Inspection equipment and methods.

More information

TV Lift System Model CL-65 Installation Instructions

TV Lift System Model CL-65 Installation Instructions TV Lift System Model CL-65 Installation Instructions Contact: Support@Nexus21.com Toll Free: (866) 500-5438 Phone: (480) 951-6885 Fax: (480) 951-6879 Revised: 01/17/17 Below is a parts list describing

More information

READ ME FIRST. Touchstone TV Lift

READ ME FIRST. Touchstone TV Lift Whisper Lift II PRO 2 READ ME FIRST 1. After completing the unpacking and uncrating of the cabinet, you will find the Owner s Manual, TV, installation hardware, and the wireless remote all together and

More information

SCANNER TUNING TUTORIAL Author: Adam Burns

SCANNER TUNING TUTORIAL Author: Adam Burns SCANNER TUNING TUTORIAL Author: Adam Burns Let me say first of all that nearly all the techniques mentioned in this tutorial were gleaned from watching (and listening) to Bill Benner (president of Pangolin

More information

Affected Products: Product Line Category Device Version Machinery Health Management. Data Analysis

Affected Products: Product Line Category Device Version Machinery Health Management. Data Analysis Knowledge Base Article Vibration Applications With Vibrating Screens Article ID: NK-1000-0572 Publish Date: 04 Mar 2015 Article Status: Article Type: Required Action: Approved General Product Technical

More information

Dennis R. Buckmaster Purdue University Agricultural & Biological Engineering

Dennis R. Buckmaster Purdue University Agricultural & Biological Engineering Managing TMR Mixers to optimize performance Dennis R. Buckmaster Purdue University Agricultural & Biological Engineering Outline Introduction Variation Among Batches Variation Within Batches Experimenting

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

Assembly and Operating Instructions

Assembly and Operating Instructions Assembly and Operating Instructions All-In-One Series Animated Lighting, Inc. 13848 Wyandotte Kansas City, MO 64145 (816) 941-0400 www.animatedlighting.com Overview The In a Box is a plug-and-play package

More information

Underground Installation of Optical Fiber Cable by Pulling

Underground Installation of Optical Fiber Cable by Pulling Application Notes Underground Installation of Optical Fiber Cable by Pulling Authors Prasanna Pardeshi and Sudipta Bhaumik Issued July 2015 Abstract This application note discusses underground fiber optic

More information

Blasting to Open Ramelli Pit

Blasting to Open Ramelli Pit Blasting to Open Ramelli Pit Author: Wes Bender This article is about a blast that was used to open Ramelli Pit. The site is located west of Doyle, California in the Plumas National Forest and is situated

More information

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SLiC Fiber Aerial Closure System

SLiC Fiber Aerial Closure System 3 SLiC Fiber Aerial Closure System SLFC 533-SP SLFC 533-TS SLFC 733-SP Instructions May 2005 78-8135-4502-3-B N C H E S R A N G E M IL L IM E T E R S.4 10.6.8 A B C 15 20 I 1.0 Kit Contents Note: Examine

More information

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE Conduit Installation A conduit cable installation involves placement of one or more optical cables inside a preinstalled

More information

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1 Fiber Optic Splice Closure 1. Introduction 1.1 General SAMJIN s SJOF-BS604B protects fiber optic splicing point in various installation conditions such as aerial, manholes, ducts, wall and direct buried

More information

Solutions to Embedded System Design Challenges Part II

Solutions to Embedded System Design Challenges Part II Solutions to Embedded System Design Challenges Part II Time-Saving Tips to Improve Productivity In Embedded System Design, Validation and Debug Hi, my name is Mike Juliana. Welcome to today s elearning.

More information

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION. STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION. GENERAL. A.) Overview. 1) The Television Fresnel fixture shall be purpose designed for television and studio lighting applications.

More information

SPECIFICATION. Optical Fiber Cable

SPECIFICATION. Optical Fiber Cable SPECIFICATION Optical Fiber Cable (GYFS) Prepared by Zhang xin Approved by Yin peng xiang 1 1 Product description GYFS is gel-free, single-jacket, single-armored cable for direct burial and duct GYFS is

More information

Processing Specification MiniBridge IDC

Processing Specification MiniBridge IDC Processing Specification MiniBridge IDC ERNI Electronics GmbH & Co. KG Seestrasse 9 l 73099 Adelberg / Germany l +49 7166 50-0 l www.erni.com Version 5 IMS Verarbeitungsspezifikationen Seite 1 von 11 Table

More information

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk Paul Vanderlaan Product Development Engineer Belden Presented at BICSI January 20, 1999 Introduction New Parameters involving

More information

Eye Splice for Brait (8-Strand Plaited Rope) Yale Cordage, Inc. 2004

Eye Splice for Brait (8-Strand Plaited Rope) Yale Cordage, Inc. 2004 Eye Splice for Brait (8-Strand Plaited Rope) Yale Cordage, Inc. 004 Purpose: These instructions detail the procedure to fabricate an eye splice in Yale s Brait products or any suitable 8-strand plaited

More information

OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE Round Messenger (ADSS) A round messenger fiber optic cable is designed for use in aerial installations

More information

1.0 DESCRIPTION. This specification covers roll-up signs to be used in temporary traffic control zones.

1.0 DESCRIPTION. This specification covers roll-up signs to be used in temporary traffic control zones. (Page 1 of 10) ROLL-UP SIGNS (MGS-04-01O) 1.0 DESCRIPTION. This specification covers roll-up signs to be used in temporary traffic control zones. 2.0 MATERIAL. 2.1 SIGNS AND OVERLAYS. 2.1.1 SUBSTRATES.

More information

Setting Up the Warp System File: Warp Theater Set-up.doc 25 MAY 04

Setting Up the Warp System File: Warp Theater Set-up.doc 25 MAY 04 Setting Up the Warp System File: Warp Theater Set-up.doc 25 MAY 04 Initial Assumptions: Theater geometry has been calculated and the screens have been marked with fiducial points that represent the limits

More information

TruePlate Structural Plate

TruePlate Structural Plate TruePlate Structural Plate Galvanized Steel and Aluminum Alloy Sizes, Shapes and Height of Cover Tables TrueNorthSteel.com info@truenorthsteel.com 866-82-511 TruePlate Structural Plate Many drainage and

More information

GS122-2L. About the speakers:

GS122-2L. About the speakers: Dan Leighton DL Consulting Andrea Bell GS122-2L A growing number of utilities are adapting Autodesk Utility Design (AUD) as their primary design tool for electrical utilities. You will learn the basics

More information

Alternative: purchase a laptop 3) The design of the case does not allow for maximum airflow. Alternative: purchase a cooling pad

Alternative: purchase a laptop 3) The design of the case does not allow for maximum airflow. Alternative: purchase a cooling pad 1) Television: A television can be used in a variety of contexts in a home, a restaurant or bar, an office, a store, and many more. Although this is used in various contexts, the design is fairly similar

More information

Force & Motion 4-5: ArithMachines

Force & Motion 4-5: ArithMachines Force & Motion 4-5: ArithMachines Physical Science Comes Alive: Exploring Things that Go G. Benenson & J. Neujahr City Technology CCNY 212 650 8389 Overview Introduction In ArithMachines students develop

More information

Starling Tab-Tension 2 Series

Starling Tab-Tension 2 Series Electric Wall/Ceiling Projection Screen Starling Tab-Tension 2 Series For: Spectra White FG and CineGrey 5D User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow

More information

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT 3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT For Tape Over Wire (TOW) and Wire-Over-Tape (WOT) Shielded Cable For 250 2000 kcmil cable with 650-mil primary insulation thickness Instructions

More information

Outline. TMR Quality as Related to Mixer Wagons. Dennis R. Buckmaster Purdue University Agricultural & Biological Engineering

Outline. TMR Quality as Related to Mixer Wagons. Dennis R. Buckmaster Purdue University Agricultural & Biological Engineering TMR Quality as Related to Mixer Wagons Dennis R. Buckmaster Purdue University Agricultural & Biological Engineering For a copy, visit https://engineering.purdue.edu/~dbuckmas look under outreach related

More information

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR 3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR Instructions July 2010 78-8135-0094-5-K 3 1.0 General 1.1 3M Fiber Optic Splice Closure 2178-XSB The

More information

Building a MidiBox LCD Cable

Building a MidiBox LCD Cable Building a MidiBox LCD Cable By Jim Henry, 3-Apr-2004 An LCD panel may be connected to the Core module by a 16 conductor flat ribbon cable. A 16 pin insulation displacement connector (IDC) terminates one

More information

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

FIBER OPTIC CABLE PULLING

FIBER OPTIC CABLE PULLING C H A P T E R 15 FIBER OPTIC CABLE PULLING THOMAS A. DOOLEY AND JERALD R. ROUNDS (with hints from Northern Lights Cable) Electrical wire installers know how to pull cable. The basic approach to pulling

More information

ATTENTION YOUR NEW KEY FOBS WILL NOT WORK UNTIL YOU HAVE LOADED THEM ON TO YOUR REMOTE CONTROL SYSTEM

ATTENTION YOUR NEW KEY FOBS WILL NOT WORK UNTIL YOU HAVE LOADED THEM ON TO YOUR REMOTE CONTROL SYSTEM ATTENTION YOUR NEW KEY FOBS WILL T WORK UNTIL YOU HAVE LOADED THEM ON TO YOUR REMOTE CONTROL SYSTEM Please identify which remote control system is operating your roller shutter/garage door and follow the

More information

Wired Troubleshooting Manual

Wired Troubleshooting Manual Wired Troubleshooting Manual Congratulations on your choice of this product. Its superior sound reproduction will provide enjoyment and entertainment. We appreciate your patronage and take pride in the

More information

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE JY992D6520B This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4AD and should

More information

Public Works Division Lighting District Fiber Optic Specifications April 2009

Public Works Division Lighting District Fiber Optic Specifications April 2009 Public Works Division Lighting District Fiber Optic Specifications April 2009 7000 Florida Street Punta Gorda, Florida 33950 Tele: 941.575.3600 Fax : 941.637.9265 www.charlottecountyfl.com/publicworks

More information

INSTALATION PROCEDURE

INSTALATION PROCEDURE INSTALLATION PROCEDURE Overview The most difficult part of an installation is in knowing where to start and the most important part is starting in the proper start. There are a few very important items

More information

USER MANUAL. CAMPLEX opticalcon

USER MANUAL. CAMPLEX opticalcon USER MANUAL CAMPLEX opticalcon CMX-OPT-CON-TST CAMPLEX Brand Fiber Gear 812 Kings Highway Sauger es, NY 12477 www.camplex.com Rev.1b Camplex CMX-OPT-CON-TST opticalcon Fiber Optic Cable Tester Most fiber

More information

INTRODUCTION. The sketch above shows the initial concept for the HRSG Internal Access Tool. 535 Old Frankstown Road Pittsburgh, PA

INTRODUCTION. The sketch above shows the initial concept for the HRSG Internal Access Tool. 535 Old Frankstown Road Pittsburgh, PA INTRODUCTION Most Heat Recovery Steam Generators (HRSGs) are not designed to allow access to the majority of the finned tubes for inspection. These tubes are spaced tightly together and are welded to headers.

More information

2178-L/S Series Fiber Optic Splice Case with Gasket

2178-L/S Series Fiber Optic Splice Case with Gasket 2178-L/S Series Fiber Optic Splice Case with Gasket Instructions for: 2178-S Splice Case 2178-LS Splice Case 2178-LL Splice Case 2181-LS Cable Addition Kit May 1997 34-7041-9949-5-A 1 Table of Contents

More information

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable Application Notes Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable Author Prasanna Pardeshi and Sudipta Bhaumik Issued November 2013 Abstract In fiber optic network, it is sometime necessary to splice

More information

TITLE: FIBER OPTIC SHOCK FIXTURES

TITLE: FIBER OPTIC SHOCK FIXTURES ENGINEERING PRACTICE STUDY TITLE: FIBER OPTIC SHOCK FIXTURES 18 January 2007 STUDY PROJECT 60GP-2006-019 FINAL REPORT Study Conducted By Dave Leight DSCC-VAT Fiber Optic Group Prepared by: Dave Leight

More information

Toughsat Flyaway Users Manual

Toughsat Flyaway Users Manual Toughsat Flyaway Users Manual TOUGHSAT FLYAWAY USERS MANUAL V.1.6 September 2012 Important warning regarding your TOUGHSAT System All power to the system (controller, modem, external network devices) MUST

More information

Christmas LED Snowflake Project

Christmas LED Snowflake Project Christmas LED Snowflake Project Version 1.1 (01/12/2008) The snowflake is a follow-on from my Christmas star project from a few years ago. This year I decided to make a display using only white LEDs, shaped

More information

THE CABLE TRAY SYSTEM

THE CABLE TRAY SYSTEM C A B L E S A N I T A T I O N C A B L E T R A Y S Y S T E M S THE CABLE TRAY SYSTEM The SILTEC cable tray system is a product, developed for optimum functionality and with focus on simplicity and accessibility,

More information