BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)

Size: px
Start display at page:

Download "BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)"

Transcription

1 BOSTON GEAR CONTROLLERS ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers

2 ACE 10 Series Noted for exceptionally low motor noise, high starting torque and cool operation in a compact size, the ACE 10 series motor controller is ideal for 1/4-3 HP applications involving conveyors, fans, packaging machines and food processing. Select from three voltage ranges and three mounting configurations including a protected chassis IP20 for mounting in the customer s enclosure, a NEMA 4 enclosure IP65 for stand-alone indoor wash down applications, or with a DIN Rail mounting kit. All ACE 10 controllers are easy to program and utilize the latest microprocessor based IGBT technology to operate at selectable carrier frequencies up to 16 khz for dependable performance in a wide range of environments. ACE Controller Family Boston Gear introduces our newest family of adjustable frequency AC motor controllers _ The ACE Series. Four different series of controllers cover a horsepower range of fractional to 800 HP for both constant and variable torque applications. These controllers utilize the latest in IGBT technology for cooler and quieter motor operation and operate using either V/Hz, open loop sensorless vector (dynamic torque) or closed loop vector control. Please contact your local representative for application assistance and information on the other ACE series controllers. Features 1/4-3 Horsepower Ratings 115/230/460 VAC, Single or Three Phase input (Three Phase output) 4-16 khz Carrier Frequencies _ selectable, for cool, quiet motor operation 50 C (112 F) Ambient Temperatures Enclosure Types: IP20 _ Protected Chassis IP65 _ NEMA 4 (indoor use) Washdown Duty Isolated Speed Reference _ for operator safety UL/cUL/ CE Mark _ world wide acceptance Fault History _ indicates last 3 faults for diagnostics DC Injection Braking _ for quick stopping 200 Hz Maximum Frequency _ for higher motor speeds Programmable Digital Inputs/Outputs _ for multiple drive and system operation Analog Input/Output _ for use with meters and follower applications 3 Preset Speeds _ for multiple speed operation Ground Fault Protection _ protects the controller against motor short to ground Available Options DIN Rail Mounting Kits Electronic Braking Resistor _ for frequent stopping EMI Filters _ for noise immunity

3 ACE 10 Specifications Output Ratings Input Ratings Braking Output Frequency Control Operation Keypad Environment (1) Single or three phase input Category Voltage 115 VAC 230 VAC 460 VAC Drive horsepower 1/4 to 1 HP 1/4 to 3 HP 1 to 3 HP Rated voltage (three phase) 200 to 240 VAC 380 to 460 VAC Overload current rating 150% for 1 minute Rated frequency 50, 60 Hz Voltage Single phase 100 to 120 VAC 200 to 240 VAC (1/4-1 HP) n/a Three phase n/a 200 to 240 VAC (2 & 3 HP) (1) 380 to 460 VAC Voltage fluctuation +10 to -15% Voltage unbalance 2% or less Frequency 50 or 60 Hz Frequency fluctuation +5 to -5% Braking torque (Internal braking) 20% Braking torque (External braking resistor required) Torque boost 0 to 10% Acceleration/ Range 0.1 to 999 seconds Deceleration time Number 1 Acceleration, 1 Deceleration Additional functions Frequency upper and lower limit, electronic thermal overload, reverse lockout, auto restart enable, line start Operation method Keypad Start/Stop by RUN/STOP key Terminal input Forward (reverse) operation, stop command, coast-to-stop command, error reset, etc Keypad ^ and keys External potentiometer 5k Ohm, 1/2 W Analog input 0 to 10 VDC, 4 to 20 ma, 0 to 20 ma Frequency setting Isolated Yes Digital inputs (2) Jog, preset speeds, stop, reset Multistep frequency Up to 3 different frequency settings Jogging operation By digital input Reference power supply voltage 10 VDC Transistor output Operation 1 signal; faults, run mode, at speed Relay output Status Analog output Signal 1 signal; output frequency Pulse output Digit display Digits 3 LED Display Motor speed, motor load, power, frequency, faults Lamp display Power on, run, panel control, operating mode Protection functions Over voltage, under voltage, momentary power loss ride through, stall prevention, output short circuit Fault codes stored in memory Last 3 Ambient temperature Altitude Relative humidity Conditions Vibration Ambient temperature Storage Humidity Standard Enclosures Optional n/a n/a (1/4 to 1 HP) 100% (2 & 3 HP) Starting frequency 0.1 to 10.0 Hz DC braking Braking current 0.0 to 20% Braking time 0.0 to 25.5 seconds Control method Sinusoidal wave PWM Maximum frequency 200 Hz Adjustment Starting frequency 0.1 to 200 Hz Carrier frequency 4 to 16 khz Stability Analog ± 0.01% Digital ± 0.01% Resolution Analog 1 Hz / 60 Hz Digital 0.1 Hz (1 to 99.9 Hz), 1 Hz (100 to 200 Hz) ^ 100% -10 to +50 C (-14 to 122 F) (+40 C (104 F) with shield sticker) 3300 Feet (1000 meters) without derating 0 to 95% (non condensing) Free from corrosive gas, dust and direct sunlight 3mm peak from 2 to 9 Hz, 9.8 m/s2 from 9 to 20 Hz, 2 m/s2 from 20 to 55 Hz, 1 m/s2 from 55 to 200 Hz -25 to 65 C (-13 to 149 F) 5 to 95% (non condensing) IP20 chassis NEMA 4 (indoor)

4 BOSTON GEAR CONTROLLERS Dimensions IP20 Chassis Shown W D H1 H Ground W1 3x.1770 (04.5) Enclosure Voltage - HP H W D W1 H1 IP20 Chassis V-1/4 to 1HP, 230V-1/4 to 1HP (131) (72) (118) (61) (116) IP20 Chassis V - 2 & 3 HP, 460V HP (143) (118) (172) (108) (127.5) NEMA 4 (Indoor) V-1/4 to 1HP, 230V-1/4 to 1HP (215.6) (140.6) (182.5) (123.4) (198.9) NEMA 4 (Indoor) V - 2 & 3 HP, 460V HP (295) (232) (211.4) (210) (274.5) Wiring Diagram Operator Panel External 24V Supply TM2 24V + _ 3 FWD 4 REV 6 SP1 7 RST 10 0V Wiring Diagram * Braking Resistor (Option) Speed Pot AC Input Multi-Function Inputs 5k 0~10V FM L2 FWD P L1 (L) (R) (S) L3 (N) (T) REV SP1 RST +12V R SW1 1 (U) T1 (V) T2 (W) T3 1 2 CON V 3 VIN (0~10V/0~20mA/4~20mA) 0V (FM-) FM+ IM Trip Relay Test Points Grounding Power ON Indicator Increases the speed or parameter value Decreases the speed or parameter value, also used for resetting faults Press to start, press again to stop 3 Digit LED Display Operation/ Programming Key Switches between frequency, function Operation/Programming Key Selects drive parameters *Customer Supplied

5 Visit Parameter List Function Code Name Function Code Name Function Code Name Fundamental Functions F00 F01 F02 F03 F04 F05 F06 F07 F08 F09 F10 F11 Factory Preset Acceleration Time Deceleration Time Operation Mode Motor Rotation Direction V/F Pattern Frequency Upper Limit Frequency Lower Limit SP1 Frequency Jog Frequency Start/Stop Control Frequency Control F12 F13 F14 F15 F16 F17 F18 F19-20 F21 Carrier Frequency Control Torque Compensation Stop Method DC Braking Time DC Braking Injection Frequency DC Braking Level Electronic Thermal Overload Protection Multifunction Input Terminal Selection Multifunction Output Terminal F22 F23 F24 F25 F26 F27 F28 F29 F30 Reverse Lock Out Momentary Power Loss Auto Restart Times Return to Factory Settings Second Preset Frequency Third Preset Frequency Direct Start Enable Software Version Fault Log Order by Catalog Number or Item Code HP Rating Rated Output Current (A) Catalog Number Item Code Weight (lbs) 115 VAC, 1 Phase, 50/60 Hz Input, IP20 Chassis 1/4 1.4 ACE101V1P0002C /2 2.3 ACE101V1P0005C ACE101V1P0010C VAC, 1 Phase, 50/60 Hz Input, IP20 Chassis 1/4 1.4 ACE102V1P0002C /2 2.3 ACE102V1P0005C ACE102V1P0010C VAC, 1 or 3 Phase, 50/60 Hz Input, IP20 Chassis ACE102V3P0020C ACE102V3P0030C VAC, 3 Phase, 50/60 Hz Input, IP20 Chassis ACE104V3P0010C ACE104V3P0020C ACE104V3P0030C VAC, 1 Phase, 50/60 Hz Input, NEMA 4 Indoor 1/4 1.4 ACE101V1P0002N /2 2.3 ACE101V1P0005N ACE101V1P0010N VAC, 1 Phase, 50/60 Hz Input, NEMA 4 Indoor 1/4 1.4 ACE102V1P0002N /2 2.3 ACE102V1P0005N ACE102V1P0010N VAC, 1 or 3 Phase, 50/60 Hz Input, NEMA 4 Indoor ACE102V3P0020N ACE102V3P0030N VAC, 3 Phase, 50/60 Hz Input, NEMA 4 Indoor ACE104V3P0010N ACE104V3P0020N ACE104V3P0030N

6 Colfax PT Group Colfax Power Transmission Group Quincy, MA Warner Electric Electromagnetic Clutches and Brakes - USA South Beloit, IL For Application Assistance: Electromagnetic Clutches and Brakes - Europe Allonnes, France +33 (0) Precision Electric Coils - USA Columbia City, IN Boston Gear Enclosed and Open Gearing, Electrical and Mechanical P.T. Components Quincy, MA For Customer Service: For Application Assistance: Formsprag Clutch - Stieber Clutch - USA Overrunning Clutches and Holdbacks Warren, MI For application assistance: Stieber Clutch - Formsprag Clutch - Europe Overrunning Clutches and Holdbacks Heidelberg, Germany +49 (0) Marland Clutch Roller Ramp and Sprag Type Overrunning Clutches and Backstops Burr Ridge, IL Nuttall Gear and Delroyd Worm Gear Worm Gear and Helical Speed Reducers Niagara Falls, NY Wichita Clutch and Industrial Clutch Pneumatic and Oil Immersed Clutches and Brakes - USA Wichita Falls, TX Pneumatic Clutches and Brakes - Europe Bedford, UK +44 (0) Ameridrives Couplings Gear Couplings, Mill Spindles, Universal Joints Erie, PA Colfax Power Transmission Group - Asia Pacific China Taiwan Singapore Thailand Australia Check Out For Application Assistance: Hayward Street Quincy, MA Fax: /03 Printed in USA

AF-300 E11 Adjustable Frequency Drive

AF-300 E11 Adjustable Frequency Drive AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed

More information

VAT 20 Adjustable Frequency Drive

VAT 20 Adjustable Frequency Drive VAT 0 Adjustable Frequency Drive VAT 0 Adjustable Frequency Drive The VAT 0 is a small, flexible, low cost, well performing AC drive designed for use in small machines such as fans and conveyors. The drive

More information

ADJUSTABLE SPEED DRIVES. nc1 Drive

ADJUSTABLE SPEED DRIVES. nc1 Drive ADJUSTABLE SPEED DRIVES nc1 Drive Ultra-Compact Sub-Micro Drive The nc1 is a sub-micro, or nano-sized drive with a full range of features to meet the needs of nearly any user. The nc1 is designed to be

More information

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. N223 Reliance Electric s MD60 AC Drive is ready to operate out-of-the-box!

More information

A L T R A I N D U S T R I A L M O T I O N. UNIBRAKE AC Motor Brakes

A L T R A I N D U S T R I A L M O T I O N. UNIBRAKE AC Motor Brakes A L T R A I N D U S T R I A L M O T I O N UNIBRAKE AC Motor Brakes UNIBRAKE decelerates or holds loads when power is off Page 4-9 Page 10-13 Page 14-17 C-Face, Power-Off Brakes Single C-Face Power-Off

More information

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O Characteristics motion servo drive - Lexium 23 - single phase 200...255 V - 1 kw - I/O Main Range of product Product or component type Device short name Complementary Format of the drive Network number

More information

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz. HVAC Farm Duty Brake 200 & 575 Volt & Controls DC 310 DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound DC & Controls 1/4-2 Hp 115/ 1 Phase 50/60 Hz. Applications: General purpose industrial use with

More information

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive nfi Practical Demonstration of VFD Motor Speed Directly Proportional to Frequency Motor RPM= (120*F)/P Powerflex- 4M 0.4 KW= 0.5 Hp

More information

UNIBRAKE AC Motor Brakes

UNIBRAKE AC Motor Brakes A L T R A I N D U S T R I A L M O T I O N UNIBRAKE AC Motor UNIBRAKE Decelerates or Holds Loads When Power is Off Page 4-9 C-Face, Power-Off Single C-Face Power-Off are designed to decelerate or hold inertia

More information

Frequency Converter EFC 3610, EFC 5610

Frequency Converter EFC 3610, EFC 5610 Frequency Converter EFC 3610, EFC 5610 2 EFC 3610, EFC 5610 frequency converter Using valuable energy responsibly Using valuable energy responsibly Rising energy costs and increasing demands for environmentally-friendly

More information

Understanding VFD. Variable Frequency Drive. nfi. nfi

Understanding VFD. Variable Frequency Drive. nfi. nfi Understanding VFD Variable Frequency Drive Practical Demonstration of VFD Delta- M Series 1.5 KW I/P: 230V 1/3 Phase O/P: 230 3 Phase VFD Status Screen Motor OFF Command Freq. Parameters Direction Amperes

More information

RYKO Italia s.r.l. V. Casale Morano Po (Al) t f

RYKO Italia s.r.l. V. Casale Morano Po (Al) t f Italia RYKO Italia s.r.l. V. Casale 43-15025 Morano Po (Al) t.0142 494411 f. 85872 June 30, 2003 ITALIA SERVICE BULLETIN - # 4-013 VFD parameter settings for conveyor equipment with Mitsubishi PLC MACHINES

More information

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer

More information

Frequency Converter EFC 3610, EFC 5610

Frequency Converter EFC 3610, EFC 5610 Frequency Converter EFC 3610, EFC 5610 2 EFC 3610, EFC 5610 frequency converter Using valuable energy responsibly Using valuable energy responsibly Rising energy costs and increasing demands for environmentally-friendly

More information

Variable Speed Drives OMRON/YASKAWA F7Z - series

Variable Speed Drives OMRON/YASKAWA F7Z - series Variable Speed Drives OMRO/YASKAWA F7Z - series Short manual: F7-series with Software for Speed control of compressors with integrated compound controller PED Power Electronics Deutschland GmbH Conradtystrasse

More information

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Simply a better drive 2

More information

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Rexroth IndraDrive Fc Compact, high-performance standard frequency converters Simply a better drive 2

More information

Frequency Converter Fv

Frequency Converter Fv 2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)

More information

SPECIFICATION NO Model 207 Automatic GTAW Welding System

SPECIFICATION NO Model 207 Automatic GTAW Welding System 1.0 Introduction The Model 207 is a completely self-contained Gas Tungsten Arc Welding (GTAW) System requiring only input power, inert gas and AMI Welding Head (or manual torch) for operation. Its small

More information

Basic, cost-effective motor control in one unit: MOVITRAC 07.

Basic, cost-effective motor control in one unit: MOVITRAC 07. Gearmotors \ Industrial Gear Units \ Drive Electronics \ Drive Automation \ Services Basic, cost-effective motor control in one unit: MOVITRAC 07. Frequency inverter 2 Basic, cost-effective motor control

More information

RM5 User Manual Warnings.

RM5 User Manual Warnings. A RM5 User Manual Warnings. Danger Hazardous High Voltage Ground the control before servicing Remove all power and wait 10 minutes Verify that no voltage is present Failure to comply will result in death

More information

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES EN K20RTD 2 WIRE - LOOP POWERED TRANSMITTER FOR PT00 AND NI00 PROBES General Description The K20RTD instrument converts a temperature signal read by a PT00 (EN 60 75) or NI00 probe with connection by 2,

More information

Inverters Selection Guide

Inverters Selection Guide Inverters Selection Guide Table of contents SYSDRIVE inverters Page Inverter - Outline...................................................................... 1 3G3EV................................................................................

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

SPECIFICATION NO NOTE

SPECIFICATION NO NOTE NOTE The Model 207-1 is a special version of the standard M-207 Power Supply. It has been altered for a special applications requiring low current operation at high arc voltages in ambient and pressurized

More information

Direct PWM. 1000/2000 Series POWERBLOK MODULE

Direct PWM. 1000/2000 Series POWERBLOK MODULE Direct PWM 1000/2000 Series POWERBLOK MODULE Features A universal servo-drive integrated on a Power Hybrid Module. Designed for direct PWM Servo Control Designed for use with Deta Tau's PMAC controllers

More information

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS GENERAL DESCRIPTION The SM-1100, SM-1500 and SM-1600 Series are multi-turn, rotary actuators, designed to meet the exacting requirements for closed-loop modulating

More information

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements. RoHS Lead-Solder-Exemption Compliant New 3.3 V and 5 V Output Models Universal Input 85-264 VAC Industry-Standard Footprint: 7.0" x 4.3" x 1.97" (177.8 x 109.2 x 50.0 mm) Input Transient & ESD Compliance

More information

Inverters Selection Guide

Inverters Selection Guide Inverters Selection Guide Table of contents SYSDRIVE inverters Page Inverter - Outline...................................................................... 1 3G3EV................................................................................

More information

EVC300i. Generator Automatic Voltage Regulator Operation Manual

EVC300i. Generator Automatic Voltage Regulator Operation Manual EVC300i Generator Automatic Voltage Regulator Operation Manual 1. INTRODUCTION The EVC300i Voltage Regulator is thyristor base to control the DC exciter field power of conventional 50 or 60 Hz brushless

More information

EVC600i. Generator Automatic Voltage Regulator Operation Manual

EVC600i. Generator Automatic Voltage Regulator Operation Manual EVC600i Generator Automatic Voltage Regulator Operation Manual 1. INTRODUCTION The EVC600i Voltage Regulator is thyristor base to control the DC exciter field power of conventional 50 or 60 Hz brushless

More information

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Panel cutout required: 1.772 x 3.622 (45mm x 92mm) 1.76 (45mm) 2.45 (62mm) 3.20 (81mm) 3.60 (91mm) 0.59 (15mm) Special Features NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description

More information

Micro-DCI 53ML5100 Manual Loader

Micro-DCI 53ML5100 Manual Loader Micro-DCI 53ML5100 Manual Loader Two process variable inputs Two manually controlled current outputs Multiple Display Formats: Dual Channel Manual Loader, Single Channel Manual Loader, Manual Loader with

More information

Product Catalog Frequency Converters

Product Catalog Frequency Converters Product Catalog Frequency Converters Contents Frequency converters product catalog 3 Contents Overview 4 EFC 3600 6 Frequency Converter Fv 12 Frequency Converter Fe 18 Accessories 24 Discover the unlimited

More information

Electronic Lineshaft With Alignment F7 Drive Software Technical Manual

Electronic Lineshaft With Alignment F7 Drive Software Technical Manual Electronic Lineshaft With Alignment F7 Drive Software Technical Manual Software Number: VSF11005X, Drive Models: CIMR-F7UXXXXXX-064, CIMR-F7UXXXXXX-065 Document Number: TM.F7SW.064, Date: 02/25/2010, Rev:

More information

Frequency Converter EFC 3610, EFC 5610

Frequency Converter EFC 3610, EFC 5610 Frequency Converter EFC 3610, EFC 5610 2 EFC 3610, EFC 5610 frequency converter Using valuable energy responsibly Using valuable energy responsibly Rising energy costs and increasing demands for environmentally-friendly

More information

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.

More information

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features Advantys STB Advantys STB Output Module DATA SHEET Description The Advantys model STBDAO5260 Digital Output Module provides 2 isolated discrete output points that operate on a 115 VAC power source. The

More information

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5. EF User Guide UD51 Second encoder small option module for Unidrive Part Number: 0460-0084-05 Issue Number: 5 www.controltechniques.com Safety Information The option card and its associated drive are intended

More information

Part-Turn Electric Multi-Turn Electric

Part-Turn Electric Multi-Turn Electric Optional 7 Handwheel Available NEMA 4 Enclosure Approvals MAR s Only (Canadian Standard Association) Enclosure NEMA 7 Enclosure Approvals MAR s Only (Canadian Standard Association) Class I, Divisions 1

More information

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4 UDC100 Universal Digital Controller 51-52-03-29 11/99 Page 1 of 4 Specification Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

Quick-disconnect cables. Adjustable mounting brackets

Quick-disconnect cables. Adjustable mounting brackets MiniSafe File No. LR90200 Operation MiniSafe 1.0 inch (25.4 mm) resolution 100 foot (30.5 m) range Individual Beam Indicator lights covered by U.S. and international patents Compact size 2.25 x 1.8 inches

More information

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load

More information

Kuhnke Technical Data. Contact Details

Kuhnke Technical Data. Contact Details Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

EG4015. Digital Generator Governor Controller User Manual

EG4015. Digital Generator Governor Controller User Manual EG4015 Digital Generator Governor Controller User Manual Digital Governor for use in Gas and Diesel Generators with smoke and idle controls. Senses generator frequency, no magnetic pickup unit (MPU) is

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

High performance circuit breakers

High performance circuit breakers Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics

More information

Installation and Operating Instructions. Vari-Watt Power Controller

Installation and Operating Instructions. Vari-Watt Power Controller Installation and Operating Instructions VariWatt Power Controller PK555 003775459 October 208 VariWatt Power Controller General The Chromalox VariWatt Controller accepts an analog control signal input

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated) INSTRUCTION MANUAL THERMOCOUPLE & INPUT MODULE (8 points; isolated) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200

More information

SOFT STARTER. We are delivering Real Cost Benefits CD AUTOMATION POWERED BY INNOVATION. Soft Starter Catalog 2018 Release n.

SOFT STARTER. We are delivering Real Cost Benefits CD AUTOMATION POWERED BY INNOVATION.   Soft Starter Catalog 2018 Release n. 380 to 600V Nominal current 6 to 200A ST with Soft Start STO with Soft Start + Overload Relay Internal by pass relay SOFT STARTER CD AUTOMATION POWERED BY INNOVATION We are delivering Real Cost Benefits

More information

MAP110 AC-DC Series Data Sheet

MAP110 AC-DC Series Data Sheet Description Single-Output Model Selection VOLTAGE RANGE OUTPUT CURRENT OUTPUT CURRENT REGULATION REGULATION %p-p (NOTE 1) ACCURACY MAP110-1005 5V 4.95V to 5.50 16A 2 0.2% 1% 1% 5.09V to 5.11V MAP110-1012

More information

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Advantys STB Advantys STB Input Module DATA SHEET Description The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Features

More information

HS-509 VIBRATION TRIP MODULE

HS-509 VIBRATION TRIP MODULE HS-509 VIBRATION TRIP MODULE 1. Overview The HS-509 is a configurable trip amplifier capable of accepting a 4-20mA signal from a HS-420 sensor and providing two trip action relay outputs along with an

More information

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay.

TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay. TE s AGASTAT relays are available in two basic operating types: On-Delay and Off-Delay. On-Delay: Provides a delay period on energization, at the end of which the switch contacts transfer. De-energizing

More information

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43 Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.

More information

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter.   ACCESSORIES. Technology Solutions Technology Solutions TEK-LCD 7801A NEMA 4X Loop-Powered Feet and Inches Level Meter ACCESSORIES www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

Gamma instabus. Technical product information

Gamma instabus. Technical product information Gamma instabus Technical product information Universal dimmer N 554D31, 4 x 300 VA / 1x 1000 VA, AC 230 V Universal dimmer N 554D31 Control of dimmable lamps, including LED without minimum load Output

More information

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters Signal Conditioners Highlights Battery powered Line powered Multi-purpose Modular-style Multi-channel Charge & impedance converters Industrial charge amplifiers & sensor simulators PCB Piezotronics, Inc.

More information

Single-Output 2000 W

Single-Output 2000 W Single-Output 2000 W 6571A-6575A Front panel and analog control of output voltage and current Fast, low-noise outputs Fan-speed control to minimize acoustic noise Protection features to ensure DUT safety

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES pag. 1/13 FEATURES Outputs: 4 x channels BUS+SEQUENCER+FADER+DIMMER+DRIVER Input: DC 12/24/48 Vdc BUS Command: DALI LOCAL Command: 4x N.O. push button (with or without memory), 0-10V, 1-10V Controls: dimmer,

More information

Bulletin 190 IEC Modular Starter System

Bulletin 190 IEC Modular Starter System Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................

More information

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218 9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,

More information

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

Indoor Linear 80W Driver SI-C215280N2KR

Indoor Linear 80W Driver SI-C215280N2KR Product Data Sheet Rev.00 2017. 2. 9 1# LED Driver Indoor Linear 80W Driver SI-C215280N2KR Constant Current LED Driver Features & Benefits Output Current Range: 1550mA Output Voltage Range: MAX 51 Vdc

More information

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable: Automation / Mini Type 2RMHF Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 1/4 inch Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution:

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Z-D-IN. RS485 Modbus Module 5 Digital Inputs S SENECA Z-PC Line EN Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - Modbus connection rules - DIP-switches Settings -

More information

Material: Weight: IP Rating: Cable: Connector:

Material: Weight: IP Rating: Cable: Connector: Automation / Mini Hollow Shaft Encoder - Ø 24 mm Hollow Bore: Ø 2 mm to Ø 6 mm Resolution up to 7.500 ppr IP 64 rating (IP 50 for flat cable option) Electrical Specifications Code: Resolution: Supply Voltage:

More information

Process transmitter RMA422

Process transmitter RMA422 Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set

More information

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Product data sheet Characteristics STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Main Range of product Product or component type Kit composition Analogue input type Analogue input number

More information

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650 M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de

More information

Kramer Electronics, Ltd.

Kramer Electronics, Ltd. Kramer Electronics, Ltd. Preliminary USER MANUAL Models: VM-5ARII, Video Audio Distribution Amplifier VM-20ARII, 1:20 Programmable Video Audio Distributor VM-1411, 1:10 Video/Audio Distributor Contents

More information

User s Manual. LG Industrial Systems G3F AT4A. LG Programmable Logic Controller

User s Manual. LG Industrial Systems G3F AT4A. LG Programmable Logic Controller User s Manual LG Programmable Logic Controller G3F AT4A GLOFA G4F AT3A LG Industrial Systems CONTENTS Chapter 1. INTRODUCTION 1.1 Features 1-1 Chapter 2. SYSTEM CONFIGURATION 2.1 Example of System Configuration

More information

Preset counters, electronic

Preset counters, electronic The multifunction preset counters Codix 923 / 924 can be used universally. These preset pulse counters, tachometers or preset timers with up to 6 presets can solve a wide variety of control and monitoring

More information

Modular Lube Lubrication Systems System Controls

Modular Lube Lubrication Systems System Controls Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid

More information

GP-500 SERIES - Low Voltage

GP-500 SERIES - Low Voltage M O T O R & G E N E R A T O R P R O T E C T I O N AUTOMATIC INSULATION RESISTANCE TESTERS Meg-Alert is an automatic, in-line insulation resistance tester and monitor with test capabilities from 500 to

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

Multifunction devices

Multifunction devices devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2

More information

Magnecraft Power Relays

Magnecraft Power Relays Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These

More information

Model Number Structure

Model Number Structure Cycle Control Units CSM DS_E_7_1 Refer to Safety Precautions for All Power Controllers. Used in Combination with the to Enable High-precision Temperature Control Use cycle control to achieve power control

More information

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Assembly. Front view. LEDs. Parametrization interface. Power Bus otation Speed Monitor Features Assembly 1-channel signal conditioner 2 V DC supply Input for 2- or -wire sensors Input frequency 10 mhz... 50 khz elay contact output Start-up override and restart inhibit

More information

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN BRK-1000 Series Ku-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon

More information

Solution Selection Guide

Solution Selection Guide Solution Selection Guide 2015-2016 Automation Systems Motion & Drives Sensing Control Components Switching Components Safety Digital Panel Meters Contents Selection Guide W-ii K3HB -X, -H, -V, -S Process,

More information

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H-SR EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

Model IQ4-PC User Manual Revision Date:

Model IQ4-PC User Manual Revision Date: Basic Specifications Supply Volts 230V 50/60Hz ±15% 115V 50/60Hz ±15% 24V DC (isolated) ±15% Power Consumption Max. 3VA (IQ4-PC-R0) Max. 6VA (IQ4-PC-R2-PSI24-RT) Operating Temperature -5 ~ +60 C Operating

More information

Accessories. Servo Motors. Servo Motors B-47. Accessories

Accessories. Servo Motors. Servo Motors B-47. Accessories Servo Motors Servo Motors Accessories Accessories Page Cables B-48 Flexible Couplings B-52 Control Module B-55 Data Setting Software B-55 Accessory Sets B-56 Battery B-56 Regeneration Units B-57 B-47 Accessories

More information

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator EA63-7D Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator SP POWERWORLD LTD Willows, Waterside, Ryhall, Stamford, Lincs, PE9 4EY, UK Tel: +44 1780 756872 -

More information

RF Semiconductor Test AXRF RF Port Upgrade Kits

RF Semiconductor Test AXRF RF Port Upgrade Kits RF Semiconductor Test AXRF RF Port Upgrade Kits 2017 Datasheet The most important thing we build is trust Overview AXRF RF Port Upgrade Kits are designed to improve and extend the capability of an existing

More information

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS Standard Configuration Vertical Mount Option FEATURES Antenna mount, weatherproof to IP-65 Automatic 5/10 MHz internal/external

More information

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56 LINEAR ACTUATORS Type S / SH 95, S / SH 80, S / SH 71, S / SH 56 moving As one of the leading manufacturers of electrical and electronic drive components and systems we offer you a wide product range for

More information

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical

More information

Multiple Band Outdoor Block Up- and Downconverters

Multiple Band Outdoor Block Up- and Downconverters Multiple Band Outdoor Block Up- and Downconverters Vertical Mount Option RF IF LO Frequency Frequency Frequency Model Band (GHz) (MHz) (GHz) Number Block Upconverters 1 12.75 13.25 0.95 1.45 11.8 UPB2-WS-13.625

More information

Single Axis Position Controller

Single Axis Position Controller SERIES P9511 Single Axis Position Controller Compact Construction Simple Go-to operation Integrated Relay Output Integrated Mains Power Supply ELEKTRO-TRADING sp. Z o.o. 44-109 Gliwice, ul. Mechaników

More information

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels The is a 4-channel universal lighting control module designed to support dimming of both forward and reverse phase type loads. A single model supports both 120 and 220-240 Volt electronic and magnetic

More information