1 Doc. No ASM (Rev 0) SLICE6 3-CHANNEL SENSOR CONNECTOR ASSEMBLY DOCUMENT INSTRUCTIONS TO PREPARE AND ASSEMBLE THREE-AXIS SENSOR TO SLICE6 CONNECTOR AND INSTALL BACKSHELL Prepared by: Diversified Technical Systems, Inc. Seal Beach, California USA (562) Fabrication process shall meet IPC-610 Class 3 Standard unless otherwise specified in writing on Purchase Order. INTELLECTUAL PROPERTY STATEMENT This document contains information that is the property of Diversified Technical Systems, Inc. (DTS). All copyright, patent and ownership rights are retained. This information shall not be disclosed, reproduced in whole or in part, or used for manufacture without prior written consent from DTS.
2 Finished Assembly Page 2 of 16 Doc. No ASM (Rev 0)
3 Components Description P/N Notes SLICE6 Sensor Connector, 3-Channel (-R) SLICE6 Sensor Connector Backshell, 3-Channel R Sensor (varies) See Mfr data sheet for signal color code Sensor ID Microcard (3 ea) (optional) (-R) Heat shrink, black; 1.2 mm diam R 1.2 mm preferred, but 3/64 will also work 26 AWG magnet wire (optional) Epoxy, LOCTITE Hysol E-20HP Isopropyl alcohol (-R) (-R) Page 3 of 16 Doc. No ASM (Rev 0)
4 ** Please read entire document before beginning assembly. ** 1. Cut sensor cable(s) to length if necessary. Insert sensor wire(s) through backshell as shown below. Note: Depending on the diameter of the cable(s) and the fit through the backshell, you may wish to add heat shrink or need to modify the backshell. If heat shrink is used, do not shrink until all solder connections are completed and you have test fit the backshell (roughly step 7). Page 4 of 16 Doc. No ASM (Rev 0)
5 2. Prepare sensor(s): Remove 5/16 (8 mm) of cable jacket. Strip and tin sensor and ground wires as shown below. 5/16 Page 5 of 16 Doc. No ASM (Rev 0)
6 3. Prepare sensor ID microcards (optional 1 ): Cut sensor ID microcard leads to length (1/2 or 13 mm) as shown below. Strip and tin microcard wires as shown in step 2. 1/2 1 If not installing sensor ID microcards, go to step 5. Page 6 of 16 Doc. No ASM (Rev 0)
7 4. Solder sensor ID microcard to the Ch 3 pins 17 and 18 as shown below. You may solder all microcards at once, however it may be easier to proceed to the next step and finish assembly of Ch 3 before completing the remaining channels. Channel 3 sensor ID Pin 1 Pin 7 Pin 13 Pin 6 Pin 12 Pin 18 Pin Assignment Signal Color Code 5 -ID/Shield (Ch 1) Black 6 +ID (Ch 1) Blue 11 -ID/Shield (Ch 2) Black 12 +ID (Ch 2) Blue 17 -ID/Shield (Ch 3) Black 18 +ID (Ch 3) Blue Page 7 of 16 Doc. No ASM (Rev 0)
8 5. Assemble sensor(s): Add a short length of 1.2 mm diameter heat shrink to the sensor Shield wire 2 for Ch 3. Solder the Shield to pin 17, in tandem with -ID, as shown below. Solder the remaining Ch 3 sensor wires to the connector per the table below. Pin 1 Pin 7 Pin 13 Pin 6 Pin 12 Pin 18 Pin Assignment Signal 1 +Ex (Ch 1) 2 +Sig (Ch 1) 3 -Sig (Ch 1) 4 -Ex (Ch 1) 5 -ID/Shield (Ch 1) 2 6 +ID (Ch 1) 7 +Ex (Ch 2) 8 +Sig (Ch 2) 9 -Sig (Ch 2) 10 -Ex (Ch 2) 11 -ID/Shield (Ch 2) ID (Ch 2) 13 +Ex (Ch 3) 14 +Sig (Ch 3) 15 -Sig (Ch 3) 16 -Ex (Ch 3) 17 -ID/Shield (Ch 3) ID (Ch 3) Sensor Color Code* * Review the manufacturer s data sheet for the signal color code for your sensor. Write the color code next to the correct signal in the table above. 2 A triaxial sensor might have only one Shield wire and may be connected to pin 5, pin 11 or pin 17 (assembler s choice). Do not connect the Shield to more than one location. Page 8 of 16 Doc. No ASM (Rev 0)
9 Channel 3 assembly completed 6. Continue with Ch 2 sensor assembly (ID per step 4 and sensor per step 5), and finish with Ch 1 sensor assembly, as shown below. (Note: A triaxial sensor might have only one Shield wire and should be soldered to ONE location only.) Channel 2 assembly completed Channel 1 assembly completed Page 9 of 16 Doc. No ASM (Rev 0)
10 7. Ensure cable jacket is positioned as close as possible to the connector. If you have used heat shrink, apply heat to shrink, keeping the heat shrink aligned with the cut edge of the jacket as much as possible. 8. Carefully fold sensor ID microcards as shown below. (The PCBs should not touch the contacts.) The entire connector assembly should be as short as practical (~11/16 or ~17 mm) in order to fit within the backshell. ~11/16 Steps 7 and 8 Page 10 of 16 Doc. No ASM (Rev 0)
11 9. Carefully insert connector assembly into backshell to test fit. ** Note orientation of backshell tab to short leg of connector. ** Carefully separate connector and backshell and adjust wires as necessary until an easy fit is achieved. Carefully separate connector and backshell before proceeding. ~11/ Add strain relief (optional): If the test fit indicates there is room for strain relief, you may add this. Wrap 26 AWG magnet wire around cable about 1/16 from jacket edge. Twist wire to gently pinch/squeeze jacket. Cut off excess wire leaving about 1/8. Bend twisted wire parallel to wrapped wire. Test fit the backshell again. The PCBs should not touch the contacts or magnet wire. If fit is too tight, do not use strain relief. Carefully separate connector and backshell before proceeding. Page 11 of 16 Doc. No ASM (Rev 0)
12 11. Carefully apply epoxy (Loctite E-20HP Hysol recommended) as shown below. Proceed immediately to next step. Page 12 of 16 Doc. No ASM (Rev 0)
13 12. Carefully insert connector with uncured epoxy into backshell, pushing the two pieces together tightly. ** Note orientation of backshell. ** Carefully wipe excess epoxy immediately from connector assembly using isopropyl alcohol. Page 13 of 16 Doc. No ASM (Rev 0)
14 13. Use Kapton tape as shown below to secure the assembly while epoxy cures overnight. (The connector and backshell should be pushed together tightly.) Page 14 of 16 Doc. No ASM (Rev 0)
15 Finished Assembly Page 15 of 16 Doc. No ASM (Rev 0)
16 Revision History Rev Date By Description July 2018 EK Initial release. Page 16 of 16 Doc. No ASM (Rev 0)
Instructions. Cable with Armor F CAUTION. October Rev A
3M Single Conductor Accessory Breakout Kits (BOK's) for use with 3M Cable Accessories (Terminations, T-Bodies and Push-On Elbows) For Use With Single Conductor Accessories On Three-Core Conductor Cables
More informationCold Shrink Straight Joint
Cold Shrink Straight Joint 3M QS2000E 22 kv Single Core Straight Joint Instruction Sheet All dimensions shown are in mm unless otherwise stated Kits contains components for one single core cable -2-2*
More information3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT
3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT For Tape Over Wire (TOW) and Wire-Over-Tape (WOT) Shielded Cable For 250 2000 kcmil cable with 650-mil primary insulation thickness Instructions
More informationIndustrial Loadbreak Elbow
Industrial Loadbreak Elbow 200 A 5, 8, and 15 kvclass 5810 Series Installation Instructions 1.0 General The 3M Industrial Loadbreak Elbow connector is a fullyshielded and insulated plug-in termination
More informationBuilding a MidiBox LCD Cable
Building a MidiBox LCD Cable By Jim Henry, 3-Apr-2004 An LCD panel may be connected to the Core module by a 16 conductor flat ribbon cable. A 16 pin insulation displacement connector (IDC) terminates one
More informationFurcation of a Central Tube Ribbon, Gel-Free, Non-Armored, 96- to 192-Fiber Cable into an OSE-UD
Furcation of a Central Tube Ribbon, Gel-Free, Non-Armored, 96- to 192-Fiber Cable into an OSE-UD P/N 004-277-AEN Issue 1 related literature Search www.corning.com/opcomm. Click on Resources. 1. Initial
More informationFISCHER MINIMAX TM SERIES
FISCHER MINIMAX TM SERIES CABLE ASSEMBLY INSTRUCTIONS WITH OPTIONAL BOOT BEND RELIEF THE RELIABLE EXPERT REQUIRED TOOLING To successfully cable the Fischer MiniMax Series tooling is required to insure
More informationDIY. How to install a PL-259 connector. Parts list: Tools list: Worthwhile projects you can build on your own
DIY Worthwhile projects you can build on your own Just like you, I often need to install a PL-259 connector on a length of coax (coaxial cable), to attach it to the mating SO-239 connector of a mobile
More informationMAGNETIC CARD READER DESIGN KIT TECHNICAL SPECIFICATION
MAGNETIC CARD READER DESIGN KIT TECHNICAL SPECIFICATION Part Number: D99821002 Rev 212 MAY 2017 REGISTERED TO ISO 9001:2008 1710 Apollo Court Seal Beach, CA 90740 Phone: (562) 546-6400 FAX: (562) 546-6301
More informationMUK REAR PANEL ASSEMBLY ASSEMBLY INSTRUCTIONS
Rev B. 13 August 2017 ASSEMBLY INSTRUCTIONS The Midnight Ultimate Keyer (MUK) consists of two functional assemblies: Rear Panel containing the interface and power connectors. Front Panel containing the
More informationHighlights: Cables & Adaptors. Stock Cable Assemblies Custom Cable Assemblies Multi-conductor Cables Patch Panels Connector Adaptors
Cables & Adaptors Highlights: Stock Cable Assemblies Custom Cable Assemblies Multi-conductor Cables Patch Panels Adaptors www.pcb.com 716-684-0001 PCB Piezotronics, Inc. Automotive Sensors Division Common
More informationHDBT Installation Guide
KRAMER ELECTRONICS LTD. HDBT Installation Guide MODELS: Kramer HDBT Cable Recommendations for Usage and Termination Guidelines For the latest information on our products and a list of Kramer distributors,
More informationASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES
ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES FOR 75 OHM AND 75 OHM HD COAXIAL CONTACTS AND MODULES Table of Contents SECTION 1 RECEIVER CONTACT ASSEMBLY INSTRUCTIONS SECTION 2 ITA CONTACT
More informationHCS - HES Cabling Systems
HCS - HES Cabling Systems Installation Manual for HCS High-Capacity Fiber-Optic Rack-Mount Cabinets Be sure to read and completely understand this procedure before applying product. Be sure to select the
More informationAmphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors
Amphenol Amphenol-Tuchel Electronics GmbH C 112 Series M12 - Connectors We connect con The company Amphenol-Tuchel Electronics is a worldwide leader in electrical connectors and contacting devices. Our
More information3M Cold Shrink Splice Kit QS-III 5514A
3M Cold Shrink Splice Kit QS-III 5514A for UniShield, Wire Shielded, Longitudinally Corrugated (LC), and Tape Shielded (Ribbon Shielded) Cable or Transitions to Concentric Neutral (CN)/Jacketed Concentric
More informationTFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)
TFT-150R-G 5-15kV Cold Applied Indoor (5-8kV Indoor and Outdoor) Termination for Copper Tape, Wire Shield, Lead Sheath, and UniShield Cable Suggested Installation Equipment (not supplied with kit) Cable
More informationUNSIGNED HARDCOPY NOT CONTROLLED
SUBJECT: APPROVED BY STATUS PURPOSE AFFECTED FUNCTIONS REFERENCES Cable and Harness Making Manager, Hardware Engineering Maintenance Revision Establishes requirements for the fabrication and inspection
More informationipad Air 2 Wi-Fi Display Assembly Replacement
ipad Air 2 Wi-Fi Display Assembly Replacement Fix a cracked or faulty screen by replacing the display assembly in an ipad Air 2 Wi-Fi. Geschreven door: Evan Noronha ifixit CC BY-NC-SA nl.ifixit.com Pagina
More informationSTRAIGHT TWO WAY JOINT3/C, PAPER INSULATED, SHIELDED, LEAD COVERED CABLE. Revised: October 10, 2008 Revised By: SGL Approved By: RHS SPLICES
STRAIGHT TWO WAY JOINT3/C, PAPER INSULATED, SHIELDED, LEAD COVERED CABLE I. INSTALLATION INSTRUCTIONS I.1. PRECAUTIONS: I.1.1. Expansion bends must be made in the cables to allow for cable movement while
More information3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN
3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-500-1000 for Jacketed Concentric Neutral (JCN) and Flat Strap Neutral Cable Instructions IEEE Std. 404 15 kv Class 150 kv BIL F CAUTION Working around
More informationUltra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height
Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.mm Mated Height U.FL Series Up to 6GHz Transmission Speed Mated Height Comparison (With E.FL series) 1.9(2.0Max) U.FL-LP(V)-00 2.(2.5Max)
More informationAdapter Selection. Entry Size (Continued) Table E. Multiplication. factors for wire bundles. with Equal Size Wires. This table provides multiplication
Table E. Multiplication Factors for Wire Bundles with Equal Size Wires This table provides multiplication factors for wire bundles of to 6 wires. To determine the approximate diameter of a wire bundle
More information3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0
3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0 for Jacketed Concentric Neutral (JCN) and Flat Strap Neutral Cable Instructions IEEE Std. 404 15 kv Class 150 kv BIL F CAUTION Working around energized
More information2179-CD Series Fiber Optic Splice Closure. Installation Instructions
2179-CD Series Fiber Optic Splice Closure Installation Instructions 1.0 Product Introduction The new 3M TM 2179-CD Series Fiber Optic Splice Closure can be used in buried, underground, aerial, and pedestal
More informationSections 1. Application Equipment 2. Cable Preparation 3. Assembly 4. Termination Procedure 5. Inspection 6. Repair 7.
Page 1 of 6 Coaxial SolderSleeve Termination with Pre-Installed Wires or PCB Termination Body, B-044, B-043, B-041, B-040, B-020, B-021, B-046, D-148 Series Cable Type Typical RG Cable # -A- RG 178 RG
More information3M Cold Shrink Splice Kit QS-III 5515A
3M Cold Shrink Splice Kit QS-III 5515A for UniShield, Wire Shielded, Longitudinally Corrugated (LC), and Tape Shielded (Ribbon Shielded) Cable or Transitions to Concentric Neutral (CN)/Jacketed Concentric
More information3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500
3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500 for Jacketed Concentric Neutral (JCN) and Flat Strap Neutral Cable Instructions IEEE Std. 404 15 kv Class 150 kv BIL CAUTION Working around energized
More informationPowerBook G4 Aluminum 12" GHz LCD panel upgrade
PowerBook G4 Aluminum 12" 1-1.5 GHz LCD panel upgrade Upgrade a 1400x1050 LCD panel. Written By: martin ifixit CC BY-NC-SA www.ifixit.com Page 1 of 18 INTRODUCTION The original LCD 1024x768 resolution
More informationQuick Term II. Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet. Quick Term II. Silicone Rubber Termination Kits
Quick Term II Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet IEEE Std. No. 48 1990 Class 1 Termination 15 kv Class 110 kv BIL Kit Contents: 3 Hi K Silicone Rubber
More information3M Cold Shrink QS4 Integrated Splice Kit QS4-15SP-2-4/0
3M Cold Shrink QS4 Integrated Splice Kit QS4-15SP-2-4/0 for Jacketed Concentric Neutral (JCN), Flat Strap, Tape Shield and Longitudinally Corrugated (LC) Cable Instructions IEEE Std. 404 15 kv Class 150
More information3M Cold Shrink Foldback Splice Jacket Kit
3M Cold Shrink Foldback Splice Jacket Kit SJ-FB Instructions! CAUTION Working around energized systems may cause serious injury or death. Installation should be performed by personnel familiar with good
More informationRAIL D-SUB BACKSHELLS
RAIL D-SUB BACKSHELLS FOR D-SUBMINIATURE CONNECTORS D-SUB BACK SHELLS /// DATA SHEET RAIL D-SUB BACKSHELLS FOR D-SUBMINIATURE CONNECTORS TE Connectivity (TE) provide a comprehensive range of ruggedized
More information3M Better Buried Closures
3M Better Buried Closures Instructions March 2016 78-0015-2945-8-A Contents: 1.0 General... 3 2.0 Kit Contents... 3 3.0 Closure Selection Guide... 4 4.0 LHS End Cap Installation... 5 5.0 Cable Preparations...
More informationiphone 7 Plus LCD Screen and Digitizer Replacement
iphone 7 Plus LCD Screen and Digitizer Replacement Replace just the bare front panel not including the home/touch ID sensor, front-facing camera and sensor cable, or earpiece speaker in an iphone 7 Plus.
More information3M Cold Shrink QS-III Splice Kit 5467A(S)-WF
3M Cold Shrink QS-III Splice Kit 5467A(S)-WF for Jacketed Concentric Neutral (JCN) Cable Instructions IEEE Std. 404 35 kv Class 250 kv BIL F CAUTION Working around energized systems may cause serious injury
More informationF CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL
3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief 7642-S-2 For Jacketed Concentric Neutral (JCN) and Concentric Neutral (CN) Cable Instructions IEEE Std. No. 48 Class
More information3M Cold Shrink Splice Kit QS-III 5416A
3M Cold Shrink Splice Kit QS-III 5416A for Jacketed Concentric Neutral (JCN) and Concentric Neutral Cable Instructions IEEE Std. 404 15 kv Class 150 kv BIL CAUTION Working around energized systems may
More informationMONO AMPLIFIER KIT ESSENTIAL INFORMATION. Version 2.2 CREATE YOUR OWN SPEAKER DOCK WITH THIS
ESSENTIAL INFORMATION BUILD INSTRUCTIONS CHECKING YOUR PCB & FAULT-FINDING MECHANICAL DETAILS HOW THE KIT WORKS CREATE YOUR OWN SPEAKER DOCK WITH THIS MONO AMPLIFIER KIT Version 2.2 Build Instructions
More informationLoose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA
Loose Tube Cable Mid-Span Access for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA NOTE: These installation instructions have been written for
More informationAerospace Fiber Optics
Aerospace Fiber Optics AFO 101, Session 2 Fiber Optic Assembly Everett Community College. All rights reserved. 1 Session Learning Objectives After completing this session you should be able to: Work safely
More informationCrimp & Cleave Termination Instructions for SEL ST Connectors
Your Optical Fiber Solutions Partner Crimp & Cleave Termination Instructions for SEL ST Connectors For Use With: ST Termination Kit (SEL, Part Number BT05402-01) 200 µm HCS Fiber-Optic Cable ST Crimp &
More informationProduct information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated
Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated R512417 966740615 1 Pcs. 090.6102 Metal patch panel with integrated cable tie shelf. 19" 1U HD patch panel 4 12-port/s
More informationQuick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2
Quick Term III 3M Cold Shrink 3 Core Indoor Termination Instruction Sheet All dimensions shown are mm unless otherwise stated Kit Contents 3 QT-III Termination Assembly 1 Cold Shrink Breakout Boot 3 Phase
More informationOCT 15 Rev B
AMP+ HVA280-3pxm XE High-Voltage Plug Connector with 1-Stage Latching Application Specification 114-32125 15 OCT 15 Rev B NOTE All numerical values are in metric units [with U.S. customary units in brackets].
More informationProcessing Specification MiniBridge IDC
Processing Specification MiniBridge IDC ERNI Electronics GmbH & Co. KG Seestrasse 9 l 73099 Adelberg / Germany l +49 7166 50-0 l www.erni.com Version 5 IMS Verarbeitungsspezifikationen Seite 1 von 11 Table
More informationFIST-GCOG2-Dx6. Follow all local safety regulations related to optical fiber plant elements.
FIST-GCOG2 I N S T A L L A T I O N I N S T R U C T I O N TC-986-IP Rev A, Mar 2017 www.commscope.com FIST-GCOG2-Dx6 Content 1 Introduction 2 General 2.1 Abbreviations 2.2 Kit contents 2.3 Tools 2.4 Accessories
More information3M Fiber Optic Wall Mount Enclosure 8430 Series
3M Fiber Optic Wall Mount Enclosure 8430 Series Installation Instructions January 2014 3 78-0013-9429-1-A Table of Contents 1.0 Description...3 2.0 Parts...4 3.0 Assembly...4 4.0 Mounting the Enclosure...6
More informationQuick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B
Quick Start Function Summary Instructions for ASHCROFT GC52 Differential Pressure Transmitter Version 6.03 Rev. B (See Complete I&M Manual for Further Detail) LOOK FOR THIS AGENCY MARK ON OUR PRODUCTS
More information3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS
3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS-350-1000 for Tape Shield, Wire Shield, UniShield, and Longitudinally Corrugated (LC) Cable Instructions IEEE Std. 404 35 kv Class 250 kv BIL F CAUTION
More informationFT-45 Ordering Information
FT-45 Ordering Information FT-45 Feed Thru Modular Plug Crimp Tool Item No. Description 30-495 FT-45 Feed-Thru Modular Plug Crimp Tool 30-4951 FT-45 Replacement Blade Cat 6 Feed-Thru RJ45 Modular Plugs
More informationFOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N
FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N In-line and butt version Cold applied re-usable fiber optic closure Contents 1 Introduction 1.1 Product description 1.2 Capacity 2 General
More information3M Better Buried Compound Compression Closure System
3M Better Buried Compound Compression Closure System Instructions March 2016 78-0015-2948-2-A Contents: 1.0 General...3 2.0 Kit Contents...3 3.0 Closure Selection Guide...4 4.0 LHS End Cap Installation...5
More information3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR
3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR Instructions July 2010 78-8135-0094-5-K 3 1.0 General 1.1 3M Fiber Optic Splice Closure 2178-XSB The
More informationTechnical Information Bulletin
June 4, 2001 #TIB0003 Units Affected: Model Serial Numbers Model Serial Numbers SVT-2PRO T2PDxxxxxxxxx SVTAV AXVDxxxxxxxxx ATLDxxxxxxxxx BJIDMAxxxxxxx SVT-2PROJ T2PJxxxxxxxxx SVTAVJ BAHJxxxxxxxxx ATLJxxxxxxxxx
More informationCANNON STANDARD page 1 of 18. Cm5 MOTOR CONNECTOR
CANNON STANDARD page 1 of 18 1 General Information... 2 1.1 Scope... 2 2 Ordering Code... 3 2.1 Housing / Motor Side... 3 2.2 Cable Side... 3 3 Explosion Drawing... 3.1 Explosion Complete Assembly... 3.2
More informationPanduit Recommended Best Case Practice Split Fibre
Panduit Recommended Best Case Practice Split Fibre Panduit Corp. 2009 BEST PRACTICES PN526 Table of Contents 1.0 Enclosure Prep... 2 2.0 Fibre Cable Prep and Installation... 2 3.0 Pigtail Installation...
More informationPivot Power RJ45 Modular Plug Connectors
Pivot Power RJ45 Modular Plug Connectors Application Specification 114-32052 07 OCT 13 i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters
More informationCold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL
Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std. 404 35 kv Class 250 kv BIL Kit Number 5798A-MT Cable Range Requirements Cable Insulation O.D.
More information3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)
3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462FN and 3M High Gel Reenterable Encapsulant 8882) Instructions April 2016 78813509979C Contents: 1.0 General... 1 2.0 Kit Contents...
More informationimac Intel 20" EMC 2133 and 2210 LCD Backlights (CCFL) Replacement
imac Intel 20" EMC 2133 and 2210 LCD Backlights (CCFL) Replacement The CCFL back lights are replaceable. I have pulled mine apart and documented my method. '''NOTE''' This is not for the feint hearted!
More informationConnection Guide of the MOTOTRBO radio to the radioserver as a control station
of the MOTOTRBO radio to the radioserver as a control station (using the PMKN4147A programming cable and a cable with the HLN9457 connector) August 2015 2 1 Introduction This guide explains how to connect
More informationNational Wire and Cable and National Cable Molding Headquarters Los Angeles California
National Wire and Cable and National Cable Molding Headquarters Los Angeles California CAPABILITIES Medical Business Machines Communications Equipment Computer Equipment Audio Systems General Instrumentation
More informationWhite Paper. Discone Antenna Design
White Paper Discone Antenna Design Written by Bill Pretty Highpoint Security Technologies Property of Highpoint Security Technologies Inc The user of this document may use the contents to recreate the
More informationINSTALLATION INSTRUCTIONS RGB / RGBW 24V LED TAPE
LLI-LCC4.4W LLI-LCCW4.4W LLI-LCCW5.8W **DANGER: Prior to installation, disconnect power at the source.** Make sure you have all components listed below: LED tape 24VDC Power Supply Connectors (if creating
More informationCable entry systems. perfect innovative smart. Cable entry systems
Cable entry systems perfect innovative smart Cable entry systems Control systems engineering Switch cabinet engineering Vehicle engineering Plant engineering Machine construction Electrical installation
More information3M Cold Shrink Rubber Splicing Kit 5552
3M Cold Shrink Rubber Splicing Kit 5552 for 5/8 kv Shielded to Shielded or Shielded to Non-Shielded Cables Instructions IEEE Std. No. 404 5 kv Class, 75 kv BIL 8 kv Class, 95 kv BIL! CAUTION Working around
More information0.3 mm Pitch, 1.5 mm Mated Height, Board- to-fine Coaxial Cable Connectors
All non-rohs products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales
More informationMedium Box for Cable Termination
FIST-MB2-T I N S T A L L A T I O N I N S T R U C T I O N Medium Box for Cable Termination Contents 1 Introduction 1.1 Product description. 2 General 2.1 Tools 2.2 Kit contents 3 Installation and pre assembling
More informationAPPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors
PPLINCES /// MT, CST-100 II ND SL-156 CONNECTORS CONNECTORS/ PPLINCES MT, CST-100 II and SL-156 Connectors Contents Introduction This catalog has been designed to assist you, our customer, identify products
More information27mm ECAM Double Cable Entry Port
27mm ECAM Double Cable Entry Port Instructions October 2006 1.0 Introduction The 3M 27mm ECAM Double Cable (External Cable Assembly Module) Entry Port is designed to accept fiber optic loose tube & central
More informationPEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION PEM1126ENG 2010-05 TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv ENGLISH 2/6 PEM1126ENG 2010-05 GENERAL INFORMATION - Check that the kit is suitable for the cable type.
More informationFIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays
FIST-MB2-S I N S T A L L A T I O N I N S T R U C T I O N FIST Medium Box for Cable Splicing Only Contents 1 Introduction 1.1 Product description 2 General 2.1 Tools 2.2 Kit contents 3 Installation and
More informationSafe, Accurate, and Repeatable
Safe, Accurate, and Repeatable It is common for high-speed data cable to utilize two or more shielded twisted conductors. This type of cable is common in all digital electronic networks, and it requires
More informationLANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU
LANmark PCB patch panel, 1HU INSTALLATION GUIDE LANmark PCB patch panel, 1 HU Document information Document reference Release September 2001 Published by Contact address BRO-009 LANmark PP 1HU 0701 Nexans
More information3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit
3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief For Jacketed Concentric Neutral (JCN) Cable and Concentric Neutral (CN) Cable 7652-S-4, 7652-S-4 (L), 7653-S-4, 7654-S-4,
More informationipad Air 2 Wi-Fi Display Assembly Replacement
ipad Air 2 Wi-Fi Display Assembly Replacement Fix a cracked or faulty screen by replacing the display assembly in an ipad Air 2 Wi-Fi. Written By: Evan Noronha ifixit CC BY-NC-SA www.ifixit.com Page 1
More informationRibbon Cable connector Compliant with MIL Standard
Ribbon Cable connector Compliant with MIL Standard HIF3B Series Features 1. Product Compliant with MIL Standard HIF3B series has been developed as a product compliant with MIL standard, and used for wide
More informationRibbon Cable connector Compliant with MIL Standard
Ribbon Cable connector Compliant with MIL Standard HIF3B Series Product Specifications Rating Features 1. Product Compliant with MIL Standard HIF3B series has been developed as a product compliant with
More informationMulti-Media Installation Guide
Multi-Media Installation Guide Coaxial Page 2 Data Plug Page 7 Data Jack Page 10 Telephone Page 13 Splicing Page 15 Cable Types Cable Types Two basic types of cable are used in multimedia installations.
More informationCoaxial Cable Feedline Choke Kit - 50 Ω
Coaxial Cable Feedline Choke Kit - 50 Ω COM-CFC-50K COM-CFC-50K-INS-Revision 2a COMTEK SYSTEMS 2013 P.O. Box 1491 - Akron, OH 44309-1491 USA Phone: (800) 777-0703 Technical Support and International: (330)
More informationCOLOUR CHANGING USB LAMP KIT
TEACHING RESOURCES SCHEMES OF WORK DEVELOPING A SPECIFICATION COMPONENT FACTSHEETS HOW TO SOLDER GUIDE SEE AMAZING LIGHTING EFFECTS WITH THIS COLOUR CHANGING USB LAMP KIT Version 2.1 Index of Sheets TEACHING
More information3 Foam Sealed Closure 2" (50 mm) with Compound Compression
3 Foam Sealed Closure 2" (50 mm) with Compound Compression Instructions 1.0 General 1.1 The 3M Foam Sealed Closure is designed to be used in the construction and maintenance of buried and underground PIC
More informationRibbon Cable connector Compliant with MIL Standard
Ribbon Cable connector Compliant with MIL Standard HIF3B Series Features 1. Product Compliant with MIL Standard HIF3B series has been developed as a product compliant with MIL standard, and used for wide
More information18mm ECAM Cable Entry Port
18mm ECAM Cable Entry Port Instructions October 2006 1.0 Introduction The 3M 18mm ECAM (External Cable Assembly Module) Cable Entry Port Kit is designed to accept fiber optic cables with external diameters
More informationInstruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER
Instruction Manual Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY 12072 1-800-833-0081 Fax 518-922-8997 www.andinst.com Instrument Model Number Instrument Serial Number MODEL RSP SANITARY
More informationM23 RJ 45 M23 Profinet M16 (10pole)
Circular Connectors Industrial Ethernet M23 Hybrid + Power, Ethernet and Signal + Single-cable-solution for HIPER- FACE DSL and EnDat 2.2 use + Data transfer up to 500 Mbit / s + Simple assembly with snap-in
More informationSoldering & handling. CLD-AP74 Rev 1. Handling XLamp CXA Family LEDs... 2 Heat Sink, Layout, Thermal Interface... 3 Case Temperature (T s
Soldering & handling CLD-AP74 Rev 1 Cree XLamp CXA Family LEDs Introduction This application note applies to XLamp CXA family LEDs, which have order codes in the following format: CXAXXXX-XXXX-XXXXXXXXX
More informationINSTALLATION INSTRUCTION PEM1423ENG ENGLISH
INSTALLATION INSTRUCTION PEM1423ENG 2013-03 ENGLISH COLD SHRINK JOINT CJ11.242 FOR SINGLE CORE CABLES WITH Cu WIRE SHIELD Uo/U = 12.7/22 kv, Um = 24 kv 2/10 CJ11.242 PEM1423ENG 2013-03 GENERAL INFORMATION
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS BEFORE INSTALLING OR ADJUSTING THIS PRODUCT, PLEASE READ THESE INSTRUCTIONS CAREFULLY. PLEASE KEEP THIS GUIDE FOR FUTURE REFERENCE FIBER OPTIC SWING-OUT PATCH PANEL INSTRUCTION
More informationSega MegaDrive 1 RGB Bypass Installation Guide Rev 1.1
Sega MegaDrive 1 RGB Bypass Installation Guide Rev 1.1 This step by step guide describes the Installation of the open source Voultar RGB Bypass Amplifier board for the original SEGA MegaDrive/Genesis 1.
More informationTable 4-1: Rating Levels
OBJECTIVES 1. Describe various level ratings that apply to telecommunication cables and jacks and identify where each is implemented. 2. Describe the various levels of the cabling category rating systems.
More informationWAH WANG HOLDINGS (HONG KONG) CO., LTD.
Wah Wang Data Sheet For 5mm Super Flux White LED High Reliable Type High Power 3 LED Chips Series RF-M05V53WUR4-B4-Q Address : Unit C, D & E, 12/F., Po Shau Centre, No. 115 How Ming Street Kwun Tong, Kowloon,
More informationCONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL
CONNECTING THE FUTURE 19" LINXS LIGHTWVE INTEGRTED CROSS-CONNECT SYSTEM USER MNUL 109003 Issue Rev 2 19" Lightwave Integrated Cross-Connect System (LINXS) User Manual Document Number 109003 Issue Rev 2
More informationINSTALLATION INSTRUCTION PEM1368ENG ENGLISH
INSTALLATION INSTRUCTION PEM1368ENG 2015-01 ENGLISH COLD SHRINK HYBRID JOINT CJH11.42 FOR SINGLE CORE CABLES WITH Cu WIRE SHIELD Uo/U = 20.8/36 kv, Um = 42 kv 2/10 CJH11.42 PEM1368ENG 2015-01 GENERAL INFORMATION
More informationCategory Index. Category Page# Category Page# Category Page# Audio Audio XLR Connecter
Category Index Category Page# Category Page# Category Page# 98 Adapters Adapter Accessories... 6-29 Adapter Kit, Coaxial Cable... 17-20 Banana Jack and Plug... 33-43 [see separate Banana Plugs & Jacks
More informationAssembly Instructions
Assembly Instructions REP Series Environmentally - Sealed Rectangular Plastic Connectors Hypertac S.A. January 2014 Assembly Instructions REP Series January 2014 1 Table of Contents I. Introduction A.
More informationPREMIUM 5e F/UTP PRODUCTS
Siemon s end-to-end cabling system is guaranteed to provide transmission performance margins in excess of industry standards for category 5e parameters, while featuring excellent EMI resistance. has been
More information2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table
FIST-GCO2-F INSTALLATION INSTRUCTION GCO2-FC GCO2-FD Content 1 Introduction 2 General 2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table 3 Installation
More informationSeries 60 Online Data Sheet
MAC Panel Company Revised: 7/9/2007 Series 60 Online Data Sheet SERIES 60 The RFI Series 60 Interface System provides advanced interface technology for the test and design engineers of today. The RFI is
More information