MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

Size: px
Start display at page:

Download "MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J"

Transcription

1 MID-EX-E Figure: MID-EX-E*010* J Robust and safe magnetic flow meter for general mining applications, optional with additional measuring Corresponds to the European standards EN (Performance Level d) and EN (Safety Integrity Level 2) for use in safety systems with the requirements according to the fuctional safety Nominal diameter available: DN10, DN19 and DN25, optional with plug couplers according to DIN and socket nipples DN32 and DN50 type SSKV (heavy version) The flow meter is completely filled with casting compound except for connection area inside. Pressure ratings available: 100 bar bar Flow measurement range: l/min (DN10) to l/min (DN25) The measurement range can be reduced by half using a switch. Optional pressure ( bar to bar) and temperature ( C) measurements Electrical connection using terminals and cable gland M25x1.5 or one of the following connectors: PROMOS type BN4160, Machaczek type ME2A10, Souriau series 845 (size 1 or 2), Hydrostar type SKK24 or SKK45M, circular connector M12x1 (Binder series 763) or Hirschmann surface mounted connector type G4 (connections optional with one additional cable gland) Power supply: 8.0 VDC VDC (power consumption 1 W) (11.0 VDC VDC on devices with current or voltage output without external power supply) Signal outputs: Frequency 5-15 Hz, Limit (switching output), Current 4-20 ma or Voltage 1-10 V CANopen (serial output) Marking according to 94/9/EC: I M2 Ex ia I (BVS 07 ATEX E 060) Marking according IEC directive: Ex ia I (IECEx BVS ) The device is approved and certified according to GB and GB for the use in China mining, the certification number is J ka052000en; Rev

2 Ordering information MID-EX 10 Device version E Compact device 20 Additional measuring S Without P With integrated pressure measuring M With integrated pressure and temperature measuring (only with CANopen, Ui = VDC) T With integrated pressure and temperature measuring (only with CANopen, Ui = VDC) Y Special version, to be specified 30 Nominal width 010 DN DN DN Special version, to be specified 40 Nominal pressure L PN100 M PN160 N PN250 O PN320 A PN420 P PN500 Y Special version, to be specified 50 Flow measuring range Y Special measuring range, to be specified 60 Pressure measuring range 000 Without bar bar bar bar bar bar 999 Special version, to be specified 70 Process connection A Female screw thread G¾" B Female screw thread G1" C Female screw thread G1¼" D Plug couplers DN10 * 2 E Plug couplers DN12 * 2 F Plug couplers DN19 * 2 G Plug couplers DN25 * 2 H Plug couplers DN31 * 2 J Socket nipple DN32 type SSKV (heavy version) K Socket nipple DN50 type SSKV (heavy version) Y Special version, to be specified 70

3 Ordering information (continuation) MID-EX 80 Inside coating 1 Polyacetal (POM) 9 Special version, to be defined 90 Electrical connection A 1x Cable gland B 2x Cable gland C 1x PROMOS connector type BN4160 D 1x PROMOS connector type BN x cable gland E 1x Machaczek connector type ME2A10 F 1x Machaczek connector type ME2A10 + 1x cable gland G 1x Souriau connector series 845, size 1 H 1x Souriau connector series 845, size 1 + 1x cable gland J 1x Souriau connector series 845, size 2 K 1x Souriau connector series 845, size 2 + 1x cable gland L 1x Hydrostar connector type SKK24 M 1x Hydrostar connector type SKK24 + 1x cable gland N 1x Hirschmann surface mounted connector type G4 O 1x Hirschmann surface mounted connector type G4 + 1x cable gland P 1x Circular connector M12x1 (Binder series 763) R 2x Circular connector M12x1 (Binder series 763) S 1x Hydrostar connector type SKK45M T 1x Hydrostar connector type SKK45M + 1x cable gland Y Special version, to be specified 100 Output function 1 1x Optocoupler output 2 2x Optocoupler output 3 1x Current output 4 2x Current output 5 1x Voltage output 6 2x Voltage output 7 1x Serial output 9 Special version, to be specified 110 Output signal Hz 2 Limit (switching output) ma (not potential-separated) ma (potential-separated * 1 ) V (not potential-separated) V (potential-separated * 1 ) 7 CANopen 8 Internal protocol 9 Special version, to be specified 71

4 Ordering information (continuation) MID-EX 120 Special equipment A B Y Standard Functional safety SIL 2 + PL d Special version, to be specified *1 A potential-separated current or voltage output requires an additional external power supply. *2 Please take notice of the maximum working pressure of the plug couplers (according to DIN 20043)! Complete order code: MID - EX - E Y - see table for measuring range Measuring ranges DN Flow measuring range * 1,2 Q M [l/min] Minimum Standard Maximum Nominal pressure P N [bar] Pressure measurement range P M [bar] Note: 1 bar = 100 kpa *1 The flow measuring range can be reduced by half using a switch. *2 Higher measuring ranges are available on request Ordering example: Flow meter with the following attributes: - Flow measuring range 0-35 l/min, - Without additional measuring, - Nominal width DN10, - Nominal pressure PN250, - Process connection with plug couplers DN10, - Frequency output 5-15 Hz, - Electrical connection with terminals and one cable gland MID-EX-ES010NY000D1A11A-35 Supplementary documentation: Operating instructions MID-EX-ES* / MID-EX-EP*: ba052000a1 (german/english) Operating instructions MID-EX-EM* / MID-EX-ET*: ba052200a1 (german/english) 72

5 Available versions: Nominal width + process connection: The following combinations are available: - DN10 with plug coupler DN10 and DN12, - DN19 with plug coupler DN19, - DN25 with plug coupler DN25 and DN31 - DN25 with socket nipple DN32 and DN50 (type SSKV heavy version) Additional measuring: The temperature measuring range (option M and T) is C (only MID-EX-E********77A). Nominal pressure + process connection: - Please take notice of the maximum pressure of the plug couplers (according to DIN 20043): DN10: Pmax = 530 bar, DN12: Pmax = 500 bar, DN19: Pmax = 450 bar, DN25: Pmax = 400 bar, DN31: Pmax = 300 bar - The maximum nominal pressure of the socket nipples DN32 and DN50 (type SSKV heavy version) is 420 bar. Flow measuring range: You need to select the option Y, because you can choose any flow measuring range for the nominal width according to the table. Output signal + output function: - The output signal limit (option 2) is only available with output function 1x optocoupler output (device version MID-EX-ES**Y000***12*). - The output signal CANopen (option 7) is only available with output function 1x serial output (device version MID-EX-EM******P77A, MID-EX-EM******R77A, MID-EX-ET******P77A or MID-EX-ET******R77A). Output signal: The version with integrated pressure and temperature measuring is only possible with CANopen output (option 7, device version MID-EX-EM******P77A, MID-EX-EM******R77A, MID-EX-ET******P77A or MID-EX-ET******R77A). Output function: - A potential-separated current or voltage output requires an external power supply. - If you select version with integrated pressure measuring, the following output functions are available: 2x optocoupler output, 2x current output or 2x voltage output. - The electrical connection option G (Souriau type 845, size 1) is only possible without additional measurings, the output is not potential-separated. - The output function option 7 (serial output) is only possible in combination with the output signal option 7 (CANopen). Output signal + electrical connection: - The electrical connection option C and D (PROMOS type BN4160) is only available with the output signal option 1 (5-15 Hz). - The output signal option 7 (CANopen) is only available with the electrical connection option P or R (circular connector M12x1, 5-pin, according to CiA DR303, part 1). Electrical connection: The electrical connection option R (2x circular connector M12x1) is only available in combination with the output function option 7 (serial output) and the output signal option 7 (CANopen). 73

6 Technical data (general): Measuring principle of the flow measuring: Electromagnetic Measuring ranges: - Flow and pressure according to table "measuring ranges" - Temperature: C Material: - Sensor: brass or bronze - Electronic housing: plastic reinforced with carbon fibre Weight: - Approx. 3.3 kg (MID-EX-E*010*) - Approx. 4.1 kg (MID-EX-E*019*) - Approx. 7.5 kg (MID-EX-E*025*) Protection according to EN 60529: - IP 65 (without electrical connection option P and R) - IP 67 (only electrical connection option P and R) Type of protection according to EN : Ex ia I Cable gland: - M25x1.5 - Clamping range mm - Tightening torque 2 Nm Electrode material: (316Ti) Ambient temperature of devices certificated acc. to ATEX: - Electrical connection A, B, G, H, J, K, N, O or P: 0 C Ta +80 C - Electrical connection L, M, S or T: 0 C Ta +70 C - Electrical connection C, D, E or F: 0 C Ta +60 C Ambient temperature of devices certificated acc. to IECEx: 0 C Ta +60 C Medium temperature: 0 C Tp +100 C Technical data (electrical): Power supply: - Optocoupler, current or voltage output with external power supply: 8.0 VDC Ui 13.5 VDC - Optocoupler, current or voltage output without external power supply: 11.0 VDC Ui 13.5 VDC - CANopen: 8.0 VDC Ui 9.0 VDC (MID-EX-EM*) or 8.0 VDC Ui 13.5 VDC (MID-EX-ET*) resp. Power consumption: 1 W Optocoupler output (flow + optional pressure measuring): - Output signal: 5-15 Hz or limit (switching output), max VDC Current output (flow + optional pressure measuring): - Output signal: 4-20 ma - Load: max. 400 Ω - Additional external power supply (only potential-separated output): 11.0 VDC Uio 13.5 VDC Voltage output (flow + optional pressure measuring): - Output signal: 1-10 V - Additional external power supply (only potential-separated output): 11.0 VDC Uio 13.5 VDC Internal inductances: Negligible Internal capacitances: - Negligible (without CANopen) - Max. 6.5 µf (only CANopen) 74 Subject to change without notice!

7 Technical data (measuring uncertainty): Flow measuring: - Max. ± 2% of end value - Typ. ± 1% of end value Pressure measuring: - Max. ± 2% of end value - Typ. ± 1% of end value Temperature measuring (only CANopen): - Max. ± 0.5% of end value - Typ. ± 0.2K of measuring value Technical data (CANopen): Pin assignment of the circular connectors M12x1: According to CiA DR303, part 1 Diagnostics functions: According to CiA DR303, part 3 Device profile: DS404 Technical data (Functional safety): The device version MID-EX-E**********B corresponds to the European standards EN (Performance Level d) and EN (Safety Integrity Level 2) for use in safety systems, for details about the technical data according to the functional safety please take a look at the declaration of conformity fs052000a1. Installation note: Figure 1: Location partially filled pipe Figure 2: Alternative location Figure 3: Locations to be avoided 75

8 Dimension sheets: 76

9 77

10 78

11 79

12 80

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread I Ex-junction box I GHG 791 001 R0001 GHG 791 001 R0006 GHG 791 0101 R000 GHG 791 0101 R0001 Technical data GHG 791 01 up to 6 terminals / GHG 791 0 up to 8 terminals Marking accd. to 94/9/EC II G Ex dem

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic. DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

PROPORTIONAL VALVES Sentronic plus

PROPORTIONAL VALVES Sentronic plus 04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO. DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:

More information

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor With analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation

More information

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001

More information

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 339. Pressure Transmitter. with G ¼ flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0. DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output

More information

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Slimline Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire: 4... 20 ma

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0.

More information

Datasheet - SRB-E-201ST

Datasheet - SRB-E-201ST 27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574

More information

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications . Ex-Escape sign luminaires Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications The robust escape sign luminaire The Ex-Lite series of explosion-protected escape sign luminaire

More information

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges

More information

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

Ordering details. Approval. Classification

Ordering details. Approval. Classification Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation

More information

Pressure transmitter For applications in hazardous areas Model IS-3

Pressure transmitter For applications in hazardous areas Model IS-3 Pressure Pressure transmitter For applications in hazardous areas Model IS-3 WIKA data sheet PE 81.58 for further approvals see page 10 Applications Chemical, petrochemical industry Oil, natural gas Machine

More information

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor LMP Screw-In Transmitter with piezoresistive Stainless Steel Sensor flush diaphragm hydrostatic level measurement of clean, thin fluid media nominal pressure ranges from 0... 40 mbar up to 0... 40 bar

More information

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43 Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.

More information

Pendant Light Fitting IEC Series 6470/2

Pendant Light Fitting IEC Series 6470/2 > Available light sources high-pressure sodium lamps (HSE) metal halide lamps (HIE) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwater-resistant aluminium www.stahl.de 11435E

More information

Level Measurement silometer FMC 420, FMC 423

Level Measurement silometer FMC 420, FMC 423 Technical Information TI 077F/00/en Level Measurement silometer FMC 420, FMC 423 For connecting to capacitance probes or Deltapilot S hydrostatic probes Main applications The is used for continuous level

More information

Mechanical flow switch for On/Off control

Mechanical flow switch for On/Off control Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...

More information

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN Multi-Barrier for PROFIBUS PA and FOUNDAION Fieldbus 10/63-6.11 EN P R O F I PROCESS FIELD BUS B U S Intrinsically safe power supply of up to 31 stations on the bus, cascadable multi-barrier Intrinsically

More information

Horn loudspeaker, Ex proof, short/long flare

Horn loudspeaker, Ex proof, short/long flare Horn loudspeaker, Ex proof, short/long flare LH3 UC25XS, LH3 UC25XL en Installation note Horn loudspeaker, Ex-proof, short/long flare Installation en 3 1 Installation 1 2 Figure 1.1 Figure 1.2 4X Figure

More information

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request

More information

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/ > 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module

More information

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter. Precision Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Version with cooling element accuracy according to IEC 0770: 0. % FSO Precision Pressure

More information

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Sentronic PLUS Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications

More information

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB

Level Switch. LS Ex KS Ex RS Ex. Manual. AQ Elteknik AB Level Switch LS Ex KS Ex RS Ex Manual Level Switch Ex Manual version 3.0 March 2013 2 1. Table of contents 1. Table of contents...3 2. Manufacturer information...4 Manufacturer Declaration of Conformity...4

More information

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to

More information

Capacitive sensor BCT5-S18-UP6X2T-H1151

Capacitive sensor BCT5-S18-UP6X2T-H1151 M18 1 threaded barrel Plastic, PA12-GF30 Teach-in and configuration via buttons on the device, pin 5 and IO-Link Wiring Diagram Functional principle Type designation Ident no. 2101100 Remark to product

More information

TFR5 Room or outdoor temperature sensor. CombiTemp TM

TFR5 Room or outdoor temperature sensor. CombiTemp TM Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical

More information

DMP 331i / DMP 333i LMP 331 i

DMP 331i / DMP 333i LMP 331 i DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma

More information

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Electronic Pressure Regulator Sentronic PLUS Sentronic PLUS Electronic Pressure Regulator General Electrical Characteristics Nominal Diameter DN (mm) Voltage

More information

Capacitance Level Measurement Electronic insert FEC 12

Capacitance Level Measurement Electronic insert FEC 12 Technical Information TI 50F/00/en Capacitance Level Measurement Electronic insert FEC Smart electronic inserts for Multicap probes DC..TE/TA and DC..E/A with HART protocol and integrated linearisation

More information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15 > 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >

More information

EXPlora. Introduction

EXPlora. Introduction Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant

More information

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded

More information

ATEX. 50D (Pneumatic) Electronic pressure switch bar, bar, bar, bar, bar

ATEX. 50D (Pneumatic) Electronic pressure switch bar, bar, bar, bar, bar 0D (Pneumatic) Electronic pressure switch -... 0 bar, -... bar, 0... 6 bar, 0... 0 bar, 0... bar Fast error detection viamulti-colour display Easy to use pressure switch with clear display and intuitive

More information

User manual Version Ex Remote station XGA 15" family type 17-71KB-45../... Ex Remote station SXGA 18" family type 17-71KB-55../...

User manual Version Ex Remote station XGA 15 family type 17-71KB-45../... Ex Remote station SXGA 18 family type 17-71KB-55../... User manual Version 3.00 Ex Remote station XGA 15" family type 17-71KB-45../... Ex Remote station SXGA 18" family type 17-71KB-55../... User manual Remote station XGA 15'' family Remote station SXGA 18''

More information

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS DATA SHEET MS 3780 INDEX OVERALL FEATURES 2 STANDARD FEATURES 2 OPTIONAL FEATURES 2 TECHNICAL DATA 2 OVERALL DIMENSIONS 3 LAYOUT 4 INSTALLATION 5 INSTALLATION RECOMMENDATIONS 6 SENSOR GROUNDING 7 SENSOR

More information

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/10 Type 605055, Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat and double thermostat with capillary or rigid thermowell

More information

2291 Guided Wave Radar Level Transmitter

2291 Guided Wave Radar Level Transmitter 2291 Guided Wave Radar Level Transmitter Product description / Function The 2291 Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids,

More information

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122 www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals

More information

SITRANS F M. Transmitter MAG 5000/6000 4/33

SITRANS F M. Transmitter MAG 5000/6000 4/33 Siemens AG 2011 Flow Measurement Overview Design The transmitter is designed as either IP67 NEMA X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack

More information

Bimetal Temperature Switch

Bimetal Temperature Switch Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,

More information

PMG. Vibration Energy Harvesters

PMG. Vibration Energy Harvesters FEATURES Designed to power high performance Wireless Sensor Nodes. High power output up to 27.5mW High reliability design, including hermetically-sealed stainless steel case. Intrinsically Safe for use

More information

Absolute encoders multiturn

Absolute encoders multiturn The Sendix multiturn encoders 5868 and 5888 with CANopen or CANopenift interface and optical sensor technology are the right encoders for all CANopen or CANopenift applications. With a maximum resolution

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Design The transmitter is designed as either IP67 NEMA 4X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP20/NEMA

More information

Feed-through terminal, 2.5 mm², Screw connection, Wemid, dark beige, TS 35

Feed-through terminal, 2.5 mm², Screw connection, Wemid, dark beige, TS 35 General ordering data Order No. 1020000000 Part designation WDU 2.5 Version EAN 4008190099633 Qty. 100 pc(s). Feed-through terminal,, Screw connection, Wemid, dark beige, Product notes Note, ordering data

More information

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD ATEX II 3 G approval Gases and vapors IIC group, zone 2 Dusts IIIC group, zone 22 When used in Ex areas, the special conditions of the approval must be observed Safety clips to prevent inadvertent detachment

More information

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore GmbH Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 26 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de Data Sheet Page /5

More information

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 2 analog

More information

Safety Light Curtain Orion1 Extended

Safety Light Curtain Orion1 Extended Safety Light Curtain is an easy to use light curtain with compact dimensions. It has two resolutions for detection of fingers and hands, and comes with advanced features like cascading, muting and blanking.

More information

Photoelectrics Through-beam Type PA18C.T..., DC

Photoelectrics Through-beam Type PA18C.T..., DC Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore Pressure Transmitter for Shipbuilding and Offshore ceramic sensor accuracy: 0.25 % FSO BFSL (0.50 % FSO IEC 60770) nominal pressure ranges from 0... 0.6 bar up to 0... 600 bar The pressure transmitter

More information

ATEX UHF RFID Long Range Reader with Integrated Antenna Zone 2 / 22 ISO

ATEX UHF RFID Long Range Reader with Integrated Antenna Zone 2 / 22 ISO Long Range Reader with Integrated Antenna Zone 2 / 22 Frequency: Protocols: ATEX Zone 2 / 22 certified UHF Long Range RFID Transponder Reader Europe: 865-868 MHz EPC Class 1 GEN 2 / ISO 18000-6C Housing

More information

LD OEM/LD PDS/LD PeCo

LD OEM/LD PDS/LD PeCo LD OEM/LD PDS/LD PeCo Features LD OEM/PDS: 360 field of view LD OEM: the basic platform to LD PeCo: 90 field of view provide customized software 14,400 Hz scan rate programs on board and offers the Class

More information

Feed-through terminal, 4 mm², Screw connection, Wemid, dark beige, TS 35

Feed-through terminal, 4 mm², Screw connection, Wemid, dark beige, TS 35 General ordering data Order No. 1020100000 Part designation WDU 4 Version EAN 4008190150617 Qty. 100 pc(s). Feed-through terminal,, Screw connection, Wemid, dark beige, TS Product notes Note, ordering

More information

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A - 400 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information

www.mete-enerji.com.tr INDUSTIAL IEC PLUGS AND SOCKETS INDUSTIAL IEC PLUGS AND SOCKETS Position of the Earthing Contact acc. to IEC 60309-2 225/400-265/460 V~ 60 Hz (1) 3 P+N+ 3 P+ 2 P+ 120/208-144/250V~

More information

Single Point Flow Monitor SW118 SW119

Single Point Flow Monitor SW118 SW119 SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either

More information

I Ex-protected connectors exlink I

I Ex-protected connectors exlink I Y-Junction-box Technical data Y-Junction-box / Marking to 94/9/EC II 2 G Ex de IIC T6/T5 / II 2D Ex td A21 T80 C/ T95 C EC-Type Examination Certificate PTB 05 ATEX 1084 IECEx-Certificate of Conformity

More information

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Data Sheet 605055 Page 1/8 Type 605055, explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22 Special features Single thermostat with capillary or rigid thermowell and double thermostat

More information

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Characteristics TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink Main Range Product name Device short name Product or component type Device application Trip unit technology Complementary Poles

More information

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO Ceramic Sensor accuracy according to IEC 600: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Contacts, or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire:

More information

A V 50Hz / V 60Hz

A V 50Hz / V 60Hz A16-22-00 400-415V 50Hz / 415-440V 60Hz Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: A16-22-00 400-415V 50Hz / 415-440V

More information

Coils for solenoid valves

Coils for solenoid valves MAKING MODERN LIVING POSSIBLE Technical leaflet Coils for solenoid valves www.danfoss.com B and A coils Encapsulated coils with long operating life, even under extreme conditions Standard coils for a.c.

More information

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional

3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional Preparation of compressed air Maintenance units and components 1 IM0046156 Version Poppet valve, Can be assembled into blocks Nominal flow 4500 l/min Nominal flow, 1 2 4500 l/min Nominal flow, 2 3 3200

More information

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Operating instructions

Operating instructions 108183 2017-05-17 Page 1 0359 Operating instructions TPPL-EX series Hazardous environments luminaires Please read the instructions carefully before starting any works! Content: 1. Safety instructions 2.

More information

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Pressure Measurement Transmitters for applications with advanced requirements (Advanced) Siemens AG 07 Y Article No. Pressure transmitters for absolute pressure from differential pressure series, SITRANS P DS III with HART 7 M 4-7 7 7 7 7-7 7 7 7 Click on the Article No. for the online configuration

More information

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5 SPACEGUARD SERIES Description 1-12 metre sensing range 16 to 56 parallel scanning beams Active height of 0 mm to 2520 mm Detector length of 1928 mm to 2648 mm 3 different channel placement models Cable

More information

Actuators IC 20, IC 40

Actuators IC 20, IC 40 Actuators IC 20, IC 40 IC 20 for basic applications with three-point step control and automatic/manual mode changeover for easy commissioning IC 40 for complex applications with programmable functions

More information

TFR5 Room or outdoor temperature sensor. CombiTemp TM

TFR5 Room or outdoor temperature sensor. CombiTemp TM Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications (pending)

More information

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

TFRH Hygienic RTD temperature sensor. CombiTemp TM

TFRH Hygienic RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Floodlight 09676E00 explosion protected floodlight for use in explosive gas atmospheres of Zone 2 as well as in areas with combustibledust of Zone 21 and Zone 22. Explosion protection

More information

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry Type 2REX-H-SR EN 60079 Electrical Specifications Code: Resolution: Supply Voltage: Voltage: Current: Incremental 1 to 10,000 ppr (pulses per revolution) 4.5 Vdc min. to 30 Vdc

More information

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description Frequency transducers Data sheet 105_en_01 PHOENIX CONTACT 01-08-19 1 Description Configurable -way isolated frequency transducer. The device is suitable for the connection of NAMUR proximity sensors (IEC

More information

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151 Smooth sonic transducer face Cylindrical housing M18, potted Connection via M12 x 1 male Teach range adjustable via pushbutton or adapter Temperature compensation Blind zone: 2.5 cm Range: 40 cm Resolution:

More information

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil Product data sheet Characteristics LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil Product data sheet Characteristics LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

General Specifications

General Specifications General Specifications WG41F11C Compact O Frame GS 14M04B10-20E-Z1 [Style: S1] Overview The WG41F11C Compact O frame is a space-saving frame designed for coating lines of battery electrode sheets. This

More information

TUC: Universal thermostat

TUC: Universal thermostat Product data sheet 3.1 21.700 TUC: Universal thermostat How energy efficiency is improved Control, monitoring and limiting according to needs and with no auxiliary energy. Features Regulates and monitors

More information

Instruction manual FA1...

Instruction manual FA1... Instruction manual FA1... NAN-KD-0006-en_V02.04 04/09/2015 Issue NORIS Automation GmbH Issue Information on issue Document ID NAN-KD-0006-de/en Issue V02.04 Date August 2015 Issued by 2015 - NORIS Automation

More information

TFRN Industrial RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full

More information

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main. Product data sheet Characteristics GV2ME06 TeSys GV2-Circuit breaker-thermal-magnetic - 1...1.6 A - screw clamp terminals Main Range Product name Device short name Product or component type Device application

More information

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main. Product data sheet Characteristics GV2ME04 TeSys GV2-Circuit breaker-thermal-magnetic- 0.4...0.63 A -screw clamp terminals Main Range Product name Device short name Product or component type Device application

More information