1 Ceramic Sensor accuracy according to IEC 600: 0. % FSO Nominal pressure from mbar up to bar Contacts, or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire: 0 ma / 0 0 V others on request Special characteristics indication of measured values on a digit LED display rotatable and configurable display module Optional versions ISversion Ex ia = intrinsically safe for gases PVDF specific versions The electronic pressure switch is the successful combination of intelligent pressure switch digital display and has been specially designed for universal usage in industry applications. The is available with flush s for viscous, pasty and highly contaminated media. As standard the offers a PNP contact and a rotable display module with digit LED display. Optional versions like e.g. an intrinsically safe version, max. four contacts and an analogue output complete the profile. Preferred areas of use are Plant and machine engineering Environmental engineering (water sewage recycling) BD SENSORS GmbH BDSensorsStraße Tel: +9 (0) 9 / D 999 Thierstein Fax: +9 (0) 9 / 98 info@bdsensors.de
2 Input pressure range Nominal pressure gauge [bar] Nominal pressure abs. [bar] Level gauge [mh O] Overpressure [bar] Burst pressure [bar] Vacuum resistance P N bar: unlimited vacuum resistance P N < bar: on request PVDF possible for nominal pressure ranges up to 60 bar Contact Standard PNP contact Options independent PNP contacts independent PNP contacts (possible with Mx, 8pin for... 0 ma/wire; V/wire on request) Max. switching current... 0 ma / and wire: contact rating ma, shortcircuit resistant; V Switch = V S V V / wire: contact rating ma, shortcircuit resistant Accuracy of contacts 0. % FSO Repeatability ± 0. % FSO Switching frequency max. 0 Hz Switching cycles > 00 x 0 6 Delay time sec max. contact for wire current signal with plug ISO 00 as well as wire current signal with ISprotection no contact possible with wire in combination with plug ISO 00 Analogue output (optionally) / Supply wire current signal... 0 ma / V S =... 6 V DC permissible load: R max = [(V S V S min ) / 0.0 A] wire current signal with... 0 ma / V S =... 8 V DC ISprotection permissible load: R max = [(V S V S min ) / 0.0 A] wire current signal... 0 ma / V S = V DC adjustable (turndown of span :) permissible load: R max = 00 wire voltage signal 0 0 V / V S =... 6 V DC permissible load: R min = 0 k Without analogue output V S =... 6 V DC Accuracy 0. % FSO accuracy according to IEC 600 limit point adjustment (nonlinearity, hysteresis, repeatability) with turndown of span the analogue signal is adjusted automatically to the new measuring range Thermal effects (Offset and Span) / Permissible temperatures Thermal error ± 0. % FSO / 0 K in compensated range... 8 C Permissible temperatures medium: 0... C electronics / environment: C storage: C for of PVDF the minimum permissible temperature is 0 C Electrical protection Shortcircuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS ( Hz) according to DIN EN Shock 00 g / msec according to DIN EN Materials Pressure port / housing standard: stainless steel.0 option for G/" open port (up to 60 bar): PVDF options for G/" flush (0.6 bar P N bar): PVDF Display housing PA 6.6, polycarbonate Seals (media wetted) standard: FKM option: EPDM (P N 60 bar) others on request Diaphragm ceramics Al O 96 % Media wetted parts, seals, diaphragm response time: < 0 msec response time: < 0 msec response time: < 0. sec response time: < msec housing stainless steel.0 stainless steel.0 PVDF pressure and level
3 Explosion protection (only for 0 ma / wire) Approval AX IBExU 06 ATEX 00 X zone : II G Ex ia IIC T Gb (connector) / II G Ex ia IIB T Gb (cable) Safety tech. maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C 0 nf, L i 0 µh Max. switching current 6 0 ma Permissible temperatures for environment... 0 C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 00 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m 6 the real switching current in the application depends on the power supply unit Miscellaneous Display digit, red segmentled display, digit height mm, range of indication ; accuracy 0. % ± digit; digital damping 0. 0 sec (programmable); measured value update sec (programmable) Option oxygen application for P N bar: Oring in FKM Vi 6 (with BAMapproval); permissible maximum values are bar / 0 C Current consumption wire signal output current: max. ma (without contacts) wire signal output current: approx. ma + signal current wire signal output voltage: approx. ma Ingress protection IP 6 Installation position any Weight approx. 00 g Operational life 00 million load cycles CEconformity EMC Directive: 0/0/EU Pressure Equipment Directive: 0/68/EU (module A) 8 ATEX Directive 0//EU not possible with flush s 8 this directive is only valid for devices with maximum permissible overpressure > 00 bar Wiring diagrams wiresystem (current) wiresystem (current/voltage) p I supply + supply contact contact A VS p I/U supply + supply signal + contact contact contact contact A/V VS Pin configuration Electrical connection Supply + Supply Signal + (only wire) Contact Contact Contact Contact Shield Mx plastic (pin) via pressure port Electrical connections (dimensions in mm) Mx metal (pin) plug housing/ Mx plastic (8pin) 6 via pressure port ISO 00 ground contact Binder series (pin) plug housing/ cable colours (IEC 60) wh (white) bn (brown) gn (green) gy (grey) pk (pink) bu (blue) rd (red) gnye (greenyellow) cable outlet PVC Ø =.9mm cable outlet PUR Ø =.mm Mx (pin) Mx (8pin) ISO 00 Binder series (pin) cable outlet 9 9 different cable types and lengths available, permissible temperature depends on kind of cable; standard: m PVC cable (without ventilation tube, permissible temperature:... 0 C)
4 Mechanical connections (dimensions in mm) G/" EN 8 G/" DIN 8 G/" EN 8 /" NPT /" NPT G/ DIN 8 G/" (DIN 8) G/" open port semiflush; M0x. 0 metric threads and others on request optionally for PN from 0.6 up to 60 bar gauge G/" flush (DIN 8) 0 possible for nominal pressure ranges PN 0 bar seal 08 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. DS0_E_0098 Tel: +9 (0) 9 / Fax: pressure +9 and (0) level 9 / 98 info@bdsensors.de
5 Pressure gauge in bar gauge in mh O 8 8 E 8 absolute in bar Input [mh O] [bar] X 0 Analogue output without 0 ma / wire 0 0 V / wire 0 ma / wire, adjustable Intrinsic safety 0 ma / wire Contact contact, contacts, contacts Accuracy 0. % Electrical connection Male plug Mx (pin) / plastic version Male plug Mx (8pin) / plastic version Male plug Mx (pin) / metal version Male and female plug ISO 00 Male plug Binder series (pin) Cable outlet incl. cable Mechanical connection G/" DIN 8 G/" EN 8 G/" DIN 8 G/" EN E T A H 0 0 N 0 0 N Seals FKM EPDM Pressure port Stainless steel.0 (6L) PVDF 8 B Diaphragm Ceramics Al O 96% Special version with Ex version max. contact possible with connector ISO 00 and output wire version only max. contact possible; with wire version no contact possible contacts and Mx, 8pin only possible in combination and together with... 0 ma/wire; V/wire on request standard: m PVC cable without ventilation tube (permissible temperature: 0 C), others on request possible for nominal pressure ranges P N 0.6 bar up to PN bar gauge, absolute on request 6 possible for nominal pressure ranges P N 0.6 bar up to P N 60 bar gauge possible for nominal pressure ranges P N 60 bar 8 PVDF only with G/" DIN 8 open (up to 60 bar) and G/" DIN 8 with flush sensor (0.6 bar P N bar), (min. permissible temperature 0 C) 9 oxygen application with FKMseal up to bar possible, flush version on request Ordering code N 0 M 0 N G/" DIN 8 with flush sensor F 0 0 G/" DIN 8 with 6 K 0 0 flush sensor G/" DIN 8 open /" NPT /" NPT standard oxygen application BD SENSORS GmbH Die in diesem Dokument beschriebenen Geräte entsprechen in ihren technischen Daten dem derzeitigen Stand der Technik. Änderungen und den Austausch von Werkstoffen behalten wir uns vor.
DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0
More informationDMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO
DMP i DMP i Precision Pressure Transmitter Stainless Steel Sensor accuracy according to IEC 600: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma wire: 0 0 V others on request
More informationDMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:
More informationDS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection
with Flush Process Connection piezoresistive pressure sensor up to independent contacts, configurable optional: analogue output Exprotection (for wire) cooling element up to 00 C nominal pressure ranges
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0,5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationDMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar
More informationDMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.
DMP 9 Industrial Pressure Transmitter with G ¼" flush diaphragm accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter DMP 9 Nominal pressure from 0... 60 bar up to 0... 600 bar Output
More informationDMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output
More informationDMP 331i / DMP 333i LMP 331 i
DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma
More informationDCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor
Industrial Pressure Transmitter with i²c interface Stainless Steel Sensor Accuracy according to IEC 60770: standard: ± 0. % FSO option: ± 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Digital
More informationDMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.
Precision Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm Version with cooling element accuracy according to IEC 0770: 0. % FSO Precision Pressure
More information- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request
DMP Industrial Pressure Transmitter for Low Pressure piezoresistive stainless steel sensor O p t i o n : f l u s h v e r s i o n accuracy: 0.75 %, 0.5 %, 0.0 %, 0.05 % FSO BFSL (0.5 %, 0.5 %, 0. %, 0.
More informationLMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor
LMP Screw-In Transmitter with piezoresistive Stainless Steel Sensor flush diaphragm hydrostatic level measurement of clean, thin fluid media nominal pressure ranges from 0... 40 mbar up to 0... 40 bar
More informationDS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections
Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing Description The electronic pressure switch is the successful combination of hygienic process connections with flush welded
More informationDMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore
Pressure Transmitter for Shipbuilding and Offshore ceramic sensor accuracy: 0.25 % FSO BFSL (0.50 % FSO IEC 60770) nominal pressure ranges from 0... 0.6 bar up to 0... 600 bar The pressure transmitter
More informationDMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore
GmbH Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 26 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de Data Sheet Page /5
More informationLMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.
Slimline Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire: 4... 20 ma
More informationPressure transmitter For applications in hazardous areas Model IS-3
Pressure Pressure transmitter For applications in hazardous areas Model IS-3 WIKA data sheet PE 81.58 for further approvals see page 10 Applications Chemical, petrochemical industry Oil, natural gas Machine
More informationTPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN
TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN Main features Ranges: from: 0...1000 to 0...5000 bar Output signal 4...20mA 2 wires / 0,1...5,1Vdc / 0.1...10.1Vdc / 0...5Vdc / 0...10Vdc
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART uilt in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and full
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationInductive sensor. 2-wire, analog output BI8-M18-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationSelection matrix for electronic pressure switches
Selection matrix for electronic pressure switches Type / series 0500 050 050 05 050 0570 050 05 05 05 050 05 05 05 055 056 Page 09 09 7 0 5 5 5 5 9 9 9 9 9 9 Technology Measuring cell ceramic / thick-film
More informationTFRN Industrial RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire HART, PA Built in graphical display, CombiView TM DFON optional Head mounted t ransmitter, FlexTop type 22xx ATEX Programmable by touch screen Easy and
More informationUltrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD
ATEX II 3 G approval Gases and vapors IIC group, zone 2 Dusts IIIC group, zone 22 When used in Ex areas, the special conditions of the approval must be observed Safety clips to prevent inadvertent detachment
More informationInductive sensor With analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation
More informationMechanical flow switch for On/Off control
Mechanical flow switch for On/Off control Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type 8010 can be combined with...
More informationInductive sensor BI1.5-EG08K-Y1
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationPhotoelectrics Through-beam Type PA18C.T..., DC
Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:
More information45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5
SPACEGUARD SERIES Description 1-12 metre sensing range 16 to 56 parallel scanning beams Active height of 0 mm to 2520 mm Detector length of 1928 mm to 2648 mm 3 different channel placement models Cable
More informationUltrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151
Smooth sonic transducer face Cylindrical housing M18, potted Connection via M12 x 1 male Teach range adjustable via pushbutton or adapter Temperature compensation Blind zone: 2.5 cm Range: 40 cm Resolution:
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationTFRH Hygienic RTD temperature sensor. CombiTemp TM
Main features Pt100 sensor element, 2- or 4-wire uilt in graphical display, CombiView TM DFON optional Head mounted transmitter, FlexTop type 22xx HART, PA ATEX 3-A, FDA Programmable by touch screen Easy
More informationPROPORTIONAL VALVES Sentronic plus
04GB-06/R0 PROPORTIONAL VALVES Sentronic plus with external pressure supply G / FEATURES Sentronic plus is a highly dynamical -way proportional valve with digital control. Sentronic plus stands for: Digital
More informationMagnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationAbsolute Encoders Multiturn
The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft
More informationMagnetic field sensor for pneumatic cylinders BIM-IKT-Y1X
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 17 mm Metal, GD-Zn Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationSITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43
Overview The MAG 6000 I/I Ex d transmitter is designed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments.
More informationMetric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar
Micro-Machined Silicon Transducers wet/dry differential mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar PXM409 Differential Series U 5-Point NIST Traceable
More informationThe full range of performance
sensors sensors P sensors PS series series The full range of performance The sensors of this series cover all important pressure ranges from -1 +600 bar with an accuracy of 0.5% f.s.. Bar, psi and further
More informationultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs
18, 30 1 design M18x1 M30x1.5 dif. reflection sensor sensing range (teachable) 30... 400mm 60... 500mm 100... 800mm 80... 1500mm 200... 2000mm 300... 3500mm PBT plastic sleeve devices with thread to EURONORM
More informationCapacitive sensor BCT5-S18-UP6X2T-H1151
M18 1 threaded barrel Plastic, PA12-GF30 Teach-in and configuration via buttons on the device, pin 5 and IO-Link Wiring Diagram Functional principle Type designation Ident no. 2101100 Remark to product
More informationTFR5 Room or outdoor temperature sensor. CombiTemp TM
Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications Technical
More informationContactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151
Compact, rugged housing Many mounting possibilities Status displayed via LED Measuring range indicated via LED Immune to electromagnetic interference Measuring range programmable via Easy Teach Output
More informationProcess transmitter RMA422
Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set
More informationConnectors, self-assembly
Sub-D connection Connectors, self-assembly 9 pin Order no. Male connector with cable outlet solder contacts, for cable ø.5....6 mm [0.1... 0. ].0000.51A.0000 () () () (5) Housing: ABS, metallized, IP0
More informationSignet 2250 Hydrostatic Level Sensor
Signet 2250 Hydrostatic Sensor *32250.090* 32250.090 Rev. A 10/06 English English Safety Instructions 1. Prior to installation or removal: Depressurize and vent system Drain below sensor level 2. Confi
More informationMicro-Machined Silicon Transducers
Micro-Machined Silicon Transducers wet/wet differential Pressure Models mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar PXM409 Differential Series Standard
More informationPressure transmitter COMPACT IO-Link,
Pressure transmitter COMPACT IO-Link, for diaphragm seal operation, Type series CA1510 Features Digital pressure transmitter with IO-Link V1.1 output signal Data transmission rate COM 3 (230.4 kbaud) Hygienic
More informationPMG. Vibration Energy Harvesters
FEATURES Designed to power high performance Wireless Sensor Nodes. High power output up to 27.5mW High reliability design, including hermetically-sealed stainless steel case. Intrinsically Safe for use
More informationSingle Point Flow Monitor SW118 SW119
SW8 SW9 SW8 SW9 Single point flow monitors with MIN/MAX monitoring function, suitable for water, oil, air and media with similar thermal conductivities (selectable by means of a medium switch). With either
More informationGuide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area
Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1
More informationElectronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de
More informationCAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry
CAPACITIVE SENSORS KAS Series 26 Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry Registrier-Nr.: 1327-01 Testing laboratory accredited according to DIN EN 45001
More informationPhotoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8
Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 35 610 mm Laser class 1, red, 655 nm, acc.
More informationPhotoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8
Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 25 300 mm Laser class 1, red, 655 nm, acc.
More informationSERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency
1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching
More informationPhotoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8
Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 25 100 mm Laser class 1, red, 655 nm, acc.
More informationSpeed sensor MiniCoder GEL 2471
Speed sensor MiniCoder GEL 2471 for electrically conducting toothed-wheels Technical information version 10.02 The MiniCoder family from Lenord + Bauer offers spacesaving solutions for the contactless
More informationPhotoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8
Transmission of process value and parametrization via IO-link 4-digit 7-segment LED display 3 buttons Output indicator (yellow) IP67/69K ECOLAB-certified Range: 35 310 mm Laser class 1, red, 655 nm, acc.
More informationConnecting cables for valves, Sub-D Type codes
Type codes NEBV C S1 G 44 K Function NEBV Connecting cables for valves Product design Standard C Easy to clean design Connection technology, left, field device side S1 S7 Sub-D socket Sub-D HD socket Cable
More informationContactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationConnecting cables for valves, round plug connectors Product range overview
Connecting cables for valves, round plug connectors Product range overview Version Type code Connection technology (Electrical connection 2) Electrical connection 1: socket M8x1 4-pin NEBV-M8W4L Plug M8x1,
More informationCSM Color sensors. Color sensors for the detection of a single color in restricted space conditions
CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance
More informationTFR5 Room or outdoor temperature sensor. CombiTemp TM
Main features Sensor in stainless steel, AISI 316L FlexHousing, Ø80 mm, stainless steel Wall or pipe mounted Applications Room temperature measurement Outdoor In cold stores ATEX applications (pending)
More informationRK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics
RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output
More informationSERIES 400 SERIES 620
x 0. 0... PUR cable type,000 Hz SERIES 00 SERIES 0 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type / Connector S,000 Hz 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type,000 Hz x
More informationLinear encoders without bearings incremental System for linear motion feedback
Features Robust magnetic sensing method Output signals A 90 B with index signal Output circuits: HTL/push-pull and TTL/RS422 Resolution up to 5 µm (4-times evaluation) Non-contact, wear-free sensing system
More informationSPACESCAN SERIES SS 02
Description 0-10 metre sensing range 12 to 384 channels Available with channel spacing of 5, 10 or 20 mm Active length of 225 mm to 1920 mm Housing length of 300 mm to 1980 mm Plug connection 18-30 V dc
More informationQuality products from a single source
Velocity sensors Quality products from a single source For more than 50 years Brüel & Kjær Vibro has been a leading manufacturer of vibration measuring instruments and machine condition monitoring systems.
More informationOnline data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS
Online data sheet SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS SGS-S08PPSW0 SLG SWITCHING AUTOATI LIGHT GRIDS A B C D E F H I J K L N O P R S T Detailed technical data Features Technology Ordering information
More informationPSI-MOS-RS232/FO 850 E Serial to Fiber Converter
PSI-MOS-RS232/FO 850 E Serial to Fiber Converter perle.com/products/serial-fiber-converters/psi-mos-rs232-fo850e-rs232-to-fiber.shtml Connect RS232 devices to fiber optic cable Extend serial data up to
More informationProcess Transmitter RMA 422
Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog
More informationMB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN
Multi-Barrier for PROFIBUS PA and FOUNDAION Fieldbus 10/63-6.11 EN P R O F I PROCESS FIELD BUS B U S Intrinsically safe power supply of up to 31 stations on the bus, cascadable multi-barrier Intrinsically
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M8 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationTechnical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.
Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE programmable switch outputs Selectable sound lobe width Synchronization options
More informationConnectors, self-assembly
SubD connection technology Connectors, selfassembly 9 pin Order no. Male connector with cable outlet solder contacts, for cable ø.... 8. mm [0.... 0. ] 8.0000.A.0000 () () () () Housing: ABS, metallized,
More information1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times
Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for
More informationPROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS
INDUCTIVE TUBULAR SENSOR M30 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationGuide for installers. METTLER TOLEDO MultiRange System solution Point Ex.
Guide for installers METTLER TOLEDO MultiRange System solution Point Ex www.mt.com/support System solution Point Ex Contents Contents Page 1 Safety precautions... 4 2 System overview... 5 2.1 Using the
More informationATEX. 50D (Pneumatic) Electronic pressure switch bar, bar, bar, bar, bar
0D (Pneumatic) Electronic pressure switch -... 0 bar, -... bar, 0... 6 bar, 0... 0 bar, 0... bar Fast error detection viamulti-colour display Easy to use pressure switch with clear display and intuitive
More informationInductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151
Rectangular, aluminium / plastic Versatile mounting possibilities LED indicates measuring range Immune to electromagnetic interferences Extremely short blind zones 12 bit resolution 4-wire, 15 30 VDC Analog
More informationConnecting cables NEBS, for sensors
Connecting cables NEBS, for sensors Connecting cables NEBS, for sensors Product range overview Function Version Type code Connection technology (Electrical connection 2) Connecting cable Cable characteristic
More informationPhotoelectric Sensors E3F2
Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel
More informationContactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Positioning element and aluminium ring not incl. output 25 bit, Gray-coded clock rate: 62.5 KHz 1 MHz Single or multiturn, length
More informationistep STEPPER MOTOR PUMP
PRODUCT INFORMATION istep STEPPER MOTOR PUMP innovative - intuitive - intelligent STEPPER MOTOR PUMP FOR DEMANDING METERING REQUIREMENTS istep - THE STEPPER MOTOR PUMP The new istep stepper motor pump
More informationM5 plug connector, 3-pin or hard-wire encapsulated cable. With. With connection cable. M5 plug connector. Active face LED
Read head CES-A-LSP-... Optimized for aluminum profile mounting LED for the indication of the door position Read head CES-A-LSP-... M plug connector, -pin or hard-wire encapsulated cable Dimension drawing
More informationPhotoelectric sensor Retroreflective Sensor with Polarizing Filter for Clear Object Detection QS18EK6XLPCQ
Transmission of process value and parametrization via IO-link Cable with male end, PVC, M8 x 1, 4-pin, 150 mm Protection class IP67 LED, all-round visible Coaxial optics Sensitivity adjusted via teach
More informationAPPLICATIONS. Automatic warehouse. Trasportation lines
INDUCTIVE TUBULAR SENSOR M12 SERIES There are millions of inductive sensors deployed in almost every area of factory automation. They detect metal objects contactless and are distinguished by a long operating
More informationMID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J
MID-EX-E Figure: MID-EX-E*010* J2013333 Robust and safe magnetic flow meter for general mining applications, optional with additional measuring Corresponds to the European standards EN 13849-1 (Performance
More informationModel ED 400 Drying and heating chambers Classic.Line with natural convection
Model ED 400 Drying and heating chambers Classic.Line with natural convection BENEFITS Uniform drying conditions thanks to APT.line technology Identical test conditions throughout the chamber interior
More informationPressure sensors with display
412 Hans Turck GmbH & Co. KG Tel. +49 208 49 52-0 Fax +49 208 49 52-264 sensors P sensors PK series series Multifaceted pneumatic specialists The PK pressure sensors are especially designed for pneumatic
More informationFlow Measurement SITRANS F M
Overview Limit switches and pulse output Batch control The MAG 6000 I/6000 I Ex is a microprocessorbased transmitter with a builtin alphanumeric display in several languages. The transmitters evaluate
More information3/2-directional valve, electrically operated, Series AS3-SOV G 3/8 - G 1/2 pipe connection ATEX optional
Preparation of compressed air Maintenance units and components 1 IM0046156 Version Poppet valve, Can be assembled into blocks Nominal flow 4500 l/min Nominal flow, 1 2 4500 l/min Nominal flow, 2 3 3200
More informationistep STEPPER MOTOR PUMP
PRODUCT INFORMATION istep STEPPER MOTOR PUMP innovative - intuitive - intelligent STEPPER MOTOR PUMP FOR DEMANDING METERING REQUIREMENTS istep - THE STEPPER MOTOR PUMP The new istep stepper motor pump
More informationRSCC. Load cells. Special features. Data sheet
RSCC Load cells Special features - Load cell with SG measurement system - aximum capacities: 50 kg to 5 t - Hermetically sealed (IP68) - Rust resistant materials - Legal for trade to 3000 divisions, test
More informationCHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS
CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 922 EX Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge, moves up and down its
More informationFTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process
FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]
More information