TABLE OF CONTENTS. Instructions:

Size: px
Start display at page:

Download "TABLE OF CONTENTS. Instructions:"

Transcription

1 TABLE OF CONTENTS Instructions: 1 Overview 1 2 Main technical parameters 1 3 Display and keyboard Display Window Indicator 4 4. Operation Power Zero 4 Modified Modified peeled cumulative weight of Manual Cumulative Automatic cumulative Cumulative weight View Clear the cumulative weight of peak-hold work 4.8 Counting scales work 6 5 Accessories 6 6 Service 7 Technical Manual (professionals to operate) Installation Wiring system operating parameters 2.1 Definition 9.2 System operating parameters system working parameters Calibration range 10 count set the average weight of 11.4 items 11 Serial Communications 12.5

2 1 Overview XL type weighing indicator is based on strain gauge sensor signal, 24-bit Σ-Δ type A / D conversion technology and MCS51 single-chip microprocessor such as large scale integrated circuit composed of high-precision, high reliability, multi-functional electronic weighing indicator. This monitor has the following main functions: Optional clear boot auto-boot or memory Automatic zero tracking Weighing units kg, lb option under run tips, overload alarm a weight, peak hold, count three modes of operation has the upper and lower limit alarm relay output Real-time calendar clock, with power to protect with zero, peeled function has a weight of manual and automatic the cumulative function an external serial printer, can print weight, total weight, etc. with RS232C, RS485 serial communication interface, can connect with computer, computer component Weighing Management System 2 Main technical parameters 2.1 A / D sampling rate: 7.5 times / sec ~ 960 times / sec (optional) 2.2 in Resolution: non-linear: 0.01% F.S 2.4 Zero drift: 0.1µV / 2.5 Span temperature coefficient: 5ppm / Net 2.6 full-scale input signal range: 2 ~ 15mV 2.7 scale units re-start signal range: -1 ~ +9 mv 2.8 analog input signal sensitivity: 0.2uV / d (minimum) 1.5uV / d (recommended) 2.9 Zero range: ± 4% FS, ± 10% FS, ± 20% FS, ± 50% FS optional 2.10 peeled range: 0 ~ +100% FS 2.11 Operating Temperature: -10 ~ Relative humidity: 90% (no condensation) 2.13 AC power: AC220V (-15% ~ 2%±+10%) 50Hz

3 2.14, the limit output relay contact capacity: DC 28V, 2A; AC 220V, 1A 2.15 Sensor Supply Voltage: DC 5V can be connected 12 not less than 800Ω impedance sensors >2.16 DC Insulation resistance: Ω5 M 2.17 Voltage: AC 1500V one minute without breakdown 2.18 AC frequency leakage 3.5 ma<current: 110mm 2.19 Dimensions: 180mm 60mm 2.20 Weight: 2.21 consumption: ~ 200mA (not including sensors)

4 3 Display and keyboard XL type weighing indicator panel layout shown in Figure 1: 3.1 display By the six high-brightness red LED and 10 LED indicator composition. LED digit height 20mm. Display 1 ordinary weighing state (F10 = 0) Display meaning Remark content ± Gross "peeled" light off ± Net "peeled" indicator light 2 to maintain peak work (F10 = 1) Display meaning Remark content ± peak "Auto" indicator light ± instant weight "automatic" light off

5 3 counting scales work (F10 = 2) Display meaning Remark content P = current item number can be modified n items weighing the number of "automatic" indicator light ± items weighing the weight of "automatic" light off 4. Date display status Display meaning Remark content.. year, month, day 5 shows the state time Display meaning Remark content.. hours, minutes, seconds 6 clear working state data Display meaning Remark content CLr1? Prompt will clear the accumulated weight of other specific operations, see 7. Demarcation of the state ("Calibration" LED) Display meaning Remark content == Enter 4-digit code A maximum weighing value b minimum display values C actual weighing value or true value into the weight d actual weighing value Delay 8 operating parameters to modify the state Display meaning Remark content Fnn = nn part number for the operating parameters of the operating parameters in two shows, the specific elements of <Technical Guidelines> Section 2.1

6 9 counting the state set the average weight of items Display meaning Remark content P = = 00 ~ 99, the item number n = average weight of the base set 10 error message Display meaning Remark content - - E calibration calibration plug plug plug is not inserted - - E operating parameters of an error by <Technical Guidelines> Check, modify operating parameters - - E A / D conversion hardware troubleshooting - - E read and write data error checking hardware - - E zero is too high when the average weight of empty weighing platform scale zero check - - E when the average weight of the weight is too small to check the sensor range selection - - E Items not set the settings for the average weight of an average weight - - E A / D initialization failed inspection, replacement of A / D converter chip - - E L - - re-start signal is too small scale units Check sensor and connection - - S H - - signal too much weight before weighing platform - - FH - - Net input signal is too large sensor and connection check Check the sensor range selection - - F L - - Net input signal is too small - - OF - - Overload 3.2 Indicators "peak" indicator - When the monitor to keep working at peak work, the lights "count" indicator - When the monitor work on counting scale work, the lights "kg" indicator light - When weighing in kg, the lights "lb" indicator light - When the weighing unit is lb, the lights "Set" indicator - When the monitor is calibrated weighing system operating parameters or set state, the lights "Auto" indicator - When the monitor is automatically accumulated working condition, the lights.

7 3.2.7 "total" light - when the display total weight is not 0, the lights "peeled" indicator - peeled operation performed when the display after the lights "stable" indicator - when weighing stability, the lights "zero" indicator - When the weighing platform in the zero state (<1/4d), the lights. 4 Operation 4.1 Power Plug in the monitor power, monitor self-test (0 to show all the whole 9, decimal point, light), the use of a boot auto-zero mode (F03 = 0), if the weight scale platform items in the selected system operating parameters F08 the zero range, the monitor automatically be set to zero. If the item weighs more than the zero range, the original weight remains unchanged. The use of memory boot mode (F03 = 1), the monitor not to turn zero, directly shows the current weight. If the sensor input signal is too small, the display shows "- - EL - -" to be prompt. 4.2 Zero In weighing mode, press the [Zero] key, if the weight scale platform items in the system operating parameters F08 selected zero range, this weight is cleared to 0. If the item weighs more than the zero range, zero operation is invalid. 4.3 Modified In weighing mode, press [SET] key, the main display "== 0000", the current change-digit flashing. With [ / Auto] key, [ / total] key into the code "1000", press [SET] key, the display shows the current date ".. ", available [ / Auto] key [ / total] key into the year, month, day. When finished, press [Exit] key to return to weighing mode. 4.4 Modified In weighing mode, press [SET] key, the main display "== 0000", the current change-digit flashing. With [ / Auto] key, [ / total] key into the code "2000", press [SET] key, the display shows the current time ".. ", available [ / Auto] key [ / total] key into hours, minutes, seconds. When finished, press [Exit] key to return to weighing mode.

8 4.5 peeled In weighing mode, press [Exit / Tare] key, if the display was not previously conducted operations over the skin (save tare = 0), the monitor will scale the current stage as the tare weight to be saved, the display shows "0 "and" peeled "indicator, weight display in the display state; previously conducted in the past, if display skin action (save the tare is not 0), press [Exit / Tare] button, the display will be saved tare Clear. "Peeled" light is off, the monitor is in display gross state. Note: Peel the range of 0 ~ +100% FS, a negative weight can not be peeled. 4.6 cumulative weight The display works in general weighing (F10 = 0), it can be manual, automatic cumulative weight, the specific methods of operation are described below: Manual Cumulative In weighing mode, press the [ / Auto] button, so that the "automatic" lights off, monitor the cumulative work in manual state. When the weight scale platform items weighing more than the system operating parameters established by the range of F09, and the weighing stability, press [ / total] key, the display will scale the current stage, the accumulated items to save weight and cumulative weight of such pick a printer, then print the current weight and accumulated weight. When the accumulated operation carried out, the "cumulative" indicator. Note: Each time the cumulative weighing, said the money must be less than 50d over to the next cumulative operation Automatic Cumulative In weighing mode, press the [ / Auto] button, so that the "automatic" is lit, the monitor is automatically accumulated working condition. When the weight scale platform items weighing more than the system operating parameters established by the range of F09, and the weighing stability, the monitor records the current weight scale platform items. Remove the item from the scale platform, the display items will be recorded in the current weight and the weight of the cumulative total of preservation, such as a printer connected, then

9 print the current weight and accumulated weight. When the accumulated operation carried out, the "cumulative" indicator. Note: Each time the cumulative weighing, said the money must be less than 50d over to the next cumulative operation Cumulative weight check In weighing mode, either manually or automatically accumulated work, when the weight scale platform items weighing less than the system operating parameters established by the range of F09, press [ / total] key, the display shows the cumulative weight. If the total cumulative weight greater than or equal one million, the first display high, and then show the low 6, the display for about 3 seconds, automatically returns to weighing mode Clear the cumulative weight In the display according to of the total weight, according to [Zero] key, the display shows "Clr?", Then press [Zero] key, then the total weight removed, "total" light goes off. If the display shows "Clr?", Press [Exit / Tare] button, then cancel the cumulative weight of cleanup, return to weighing mode. 4.7 Peak to maintain work "Technical Guide" 2.2, the system operating parameters F10 = 1, display the work in the peak-hold work, panel on "peak" indicator. In weighing mode, press the [ / Auto] button to toggle the display of the peak remains active. When "Auto" indicator, the indicator displays the status of work in the peak hold, display window always displays the largest ever imposed by the weight (force value), when the applied weight (force value) is removed, even after the peak display unchanged. Keep working at the peak display, press [ / total] key, to keep the display clear display of the peak, the peak re-start measurement. When "Auto" indicator goes off, indicating the peak hold display in a non-working state. Display window display with the applied weight (force values) with changes.

10 4.8 Counting Scales work "Technical Guide" 2.2, the system operating parameters F10 = 2, display the work in the counting scale work, the panel "count" indicator. The monitor can be counted 100 different items weighing, weigh before making the count, should be "Technical Guidelines" section 4, the average weight of items to count setting. And to ensure that the current number of items to be counted with the number of items weighing objects in line. In weighing mode, press [ / total] key, the display shows the current item number "P = XX", where XX is the current item number, can be used [ / Auto], [ / total] key to change. After editing, press the [exit] key to return to weighing mode. If the current item number corresponding to the average weight of items not been set, the display shows "- - E6 - -", should be "Technical Guidelines" section 4, the average weight for this item set. In weighing mode, press the [ / Auto] button to toggle the display of the count and weigh the work of the state. When "Auto" indicator, the indicator displays the status of work in the count, the display shows "n XXXXX", where XXXXX is the number of items to be said. When "Auto" indicator is off, indicating that the monitor is in working condition weighing, display windows is called the weight, that is the same way as an ordinary weighing. 5 Accessories Supplied, each weighing XL10000 following items are supplied with the monitor, the file: 6 service 6.1 Products from the date of sale within one year, in the correct installation, use conditions, the emergence of product quality caused by the failure, the company responsible for three bags. 6.2 Non-product quality reasons, such as disassembly, improper operation, the machine displays water moisture and other damage caused by human, not a repair area, but the company is responsible for long-term maintenance for the user, charge the fee.

11 6.3 and from the packaging, transportation and other costs by the user self-care, maintenance of the company after shipping agent shipping. 6.4 Product quality problems or other operational matters, please contact our Marketing Department. (Products or instructions to modify the contents of some changes, which do not affect the use, no other description) 7 wiring installed by 1 Installation Wiring 1.1 DC DC power input (see Figure 1) 1.2 Power input stream (see Figure 1) 1 - DC +; 2 - DC-; (7.5 ~ 40 V/1A) 1.3 Connection definition 1.4 upper and lower drive relay output optocoupler 1.5 LOADCELL sensor input (E +) - Positive power supply for the bridge sensor; (S +) - the positive side of the sensor signal; (S-) - the negative side of the sensor signal; (E-) - Sensors for Bridge Negative power supply; 8 system operating parameters Definition 8.1 System operating parameters (No special requirements set by the shaded, except for fractional electric set) Parameter Name Parameter Value Meaning Notes F01 0 fixed filter Filtering approach A shallow filter 2 moderate filtering

12 3 depth filter F02 0 kg Weight unit 1 lb F03 0 start auto-zero Power mode 1 Memory Power F04 0 against zero capture 1 allows the zero capture F bit / S Serial communication baud rate selection bit / S bit / S bit / S F d Dynamic sensitivity 1 1d 2 2d 3 3d F Zero tracking rate d / s 2 0.5d / s 3 1d / s F08 0 4% FS Choose zero-range 1 10% FS 2 20% FS 3 50% FS

13 F09 0 1% FS Automatic Weighing range selection 1 5% FS 2 10% FS 3 20% FS F10 0 GM weighing Display options work A peak hold 2 Counting Scale 3 spare F HZ A / D output rate selection 1 15HZ 2 30HZ 3 60HZ 4 120HZ 5 240HZ 6 480HZ 7 960HZ F Decimal point F13 XXXXXX lower limit / (standard value) F14 XXXXXX Upper limit (lighter values) (Emphasis on value)

14 F15 XXXXX Calibration factor Write down this argument, the next input directly without calibration XXXXX F16 0-response communication Serial communication A continuous transmission F17 00 ~ 49 Serial Address Note 1: When the value is less than said lower limit, the "lower limit" to drive an external relay optocoupler. (NC) Note 2: When the weight value is greater than the upper limit, the "cap" external drive optocoupler relay (normally open) 8.2 system working parameters In weighing mode, press [SET] key, the main display "== 0000", the current change-digit flashing. With [ / Auto] key, [ / total] key into the code "0712", press [SET] key to enter the system operating parameters to set the state operating parameters into the system setup mode, display shows "F01 ". One the original settings for the F01, and flashing. Available [ / total] key to change the value of F After setting F01, press [SET] key, display shows the value of the system operating parameters F02 "F02 ", continuously press the [SET] key to switch between the F01 ~ F15. Used in conjunction with [ / Auto] key and [ / total], all system operating parameters can be set to complete the system operating parameters set, press [Exit] key to save the system operating parameters, return to weighing mode. 9 Calibration range After replacing the monitor or sensor, according to the following steps to re-calibrate the accuracy of:

15 In weighing mode, press [SET] key, display shows "== 0000", the current change-digit flashing. Available [ /] key to automatically shifted to the right to modify the current position, with the [ / total] key to modify the current value plus 1 bit. Into the code "0711", press [SET] key, enter the range of calibration status. 9.3 into the span calibration state, the display shows the prompt "- - A - -", you have successfully entered range calibration state; press [SET] key, display windows, said maximum value " ", available at this time [ / Auto] key [ /] keys to modify the maximum cumulative weight value. For example, [3], [0], [0], [0], [0]. 9.4 Press [SET] key, display windows, dividing the value of "b ", available at this time [ / Auto] key [ / total] key to modify the division value, for example, [1], [0]. 9.5 Press [SET] key, display shows the prompt "- - C - -", then press [SET] key, display windows, said value " ", scale units can be cleared at this time empty and press [Zero] key. Display shows " " After a few seconds, the display will be at this time of the weighing scale platform as the new value of zero to be preserved, the main display "C 0". The controller re-start the weighing platform to allow the sensor input signal range for the-1mv ~ +9 mv, if the re-start signal is too small, then the display prompts "--EL--", if the start signal is too heavy, then the display prompts "- - SH - -". 9.6 When the display shows "0", the increase in the scale platform a certain amount of standard weight (not necessarily for the maximum capacity), to be weighing stable, with the [ / Auto] key [ /] key to set the cumulative into the true value added by weight. When the weight began to set value, the display shows the input value. 9.7 Press [SET] key, display shows " " After a few seconds, if the net input signal is too small, the display prompts "- - FL - -", if the net input signal is too large, then the display window prompts "- - FH - -". The controller allows full-scale input signal range of the net 2mV ~ 15mV. Appropriate if the input signal range, the display shows "d ", this " " standard weight is the weight of the added value. This dissecting, by weight, the weighing error detection. (When weighing shows is negative, or weighing is 6 digits, the prompt

16 d not shown). 9.8 Continuous press [SET] key to enable the calibration status "- - A - -", "b XX", "- - C - -", "d XXXXX" to switch between. In the show "d XXXXX", the available [ / total] key and [ / Auto key to said upper and lower value of the fine-tuning. 9.9 complete the range of calibration, press [Exit / Tare] key to save the calibration parameters, return to weighing mode. Note: The system should be done first by 2.2 operating parameters set, then over the span calibration work. 10 count set the average weight of items Counting scales in the display set to work, count on even small items weighing before the count to be weighing on the average weight of items to set, the display can be set up to average weight of 100 kinds of goods, the specific set method as follows: 10.1 In weighing mode, press [SET] key, the main display "== 0000", the current change-digit flashing. With [ / Auto] key, [ / total] key into the code "1103", press [SET] key to enter the set state counts the average weight of items. Average weight of 10.2 set items into the count state, the display window displays the first item number "P = XX". Available [ / Auto], [ / total] key to set the item number "00" ~ "99" between any number After item number set, and weighing platform empty, press [SET] key, display shows " " After a few seconds, the display shows "n = XXX", tips to be placed on the weighing platform to set the average weight of the base materials. Press [ / total], can make the base in the "010", "020", "040", "050",..., "4500", "5000" to switch between Tip display items according to the base, put on stage in the scale specified number of items, press [SET] key, display shows " " After a few seconds, the display to calculate the average weight of the item and automatically be saved. Meanwhile, the display shows the items under an item number "P = XX", can be under the average weight of an item set.

17 Average weight of 10.5 set items to complete the count, press the [exit] key to return to weighing mode. 11 Serial Communications 11.1 Hardware Interfaces RS232C RS communication a. full-duplex, response type (RS232C); b. Continuous transmission type Responsive Communications (operating parameters F16 = 0) Not required unless serial communication is used to a host computer Specifications Baud rate: B = 1200 / s, 2400 / s, 4800 / s, 9600 / s optional. Start bit: 1. Data bits: 8. Stop bit: 1. Parity: even parity. Response sequence: Host: S O H A D R S T X BLOCK E T X B C C A C K Slave: S O H A D R S

18 T X BLOCK E T X B C C SOH = 01H; ADR - Address from the machine operating parameters F17 = Set the value of +30 H; Example: F17 = 00, then ADR = H = 30H; F17 = 49, then ADR = 49H +30 H = 79H. ACK = 06H; NAK = 15H; STX = 02H; ETX = 03H. BLOCK command sequence for the host or the slave acknowledges the data sequence. BCC checksum = from the STX to the character after (not including STX) begins until the ETX (including ETX), Calculated individually for each character different or after the final, and 30H "with or." Example: Let the contents of ASC BLOCK Code "G" is 47H, then the BCC checksum is calculated as follows:π BCC hexadecimal codeπasc "G" 47H 47H ETX 03H 44H 30H 74H and 30H phase or Communications Command take the current weight value: Host command format: "G" Slave Response format: a. Normal: "QS-W W W W W W emm" Of which: S is a slave working conditions: S = "0" - weighing stability; S = "1" weighing were not sure. "-" For the sign, "-" or "+"; e 10e); as a decimal index (0. WWWWWW mm for the weighing units (kg or lb). b. error: "Em" m = command format error; m = from the weighing machine is too small; m = re-start from the machine too heavy; m = slave

19 overload zero: Host command format: "Z" Slave Response format: a. Normal: "Q" b. error: "Em" m = command format error; m = from the weighing machine is not in the state, can not be zero Continuous transmission of communication (the operating parameters F16 = 1) Technical parameters: baud rate: B = 1200 / s, 2400 / s, 4800 / s, 9600 / s optional. Start bit: 1. Data bits: 7. Stop bit: 2. Parity: even parity. Data format: 1,234,567,891,011,121, S T X Shape State Word Festival A state State Word Festival B-like State Word Festival C shows the value of tare weight value M S D L S D M S D L S D C

20 R Inspection Search And Note: STX = 02H (text start code); CR = 0DH (Enter code); Shows the weight values and tare values are six significant digits. Inspection and is including STX and CR characters, including all the lower seven bits of the sum, and several of the low-seven pairs of 2's complement as a check and a low 7, the first 8-bit check and its low 7 bit even parity bit. A definition of the status byte: D2, D1, D0 --- decimal point position D2 D1 D0 decimal point position X (no decimal) 011. X (1 decimal) 100. XX (2 decimal places) 101. XXX (3 decimal places) 110. XXXX (4 decimal places) D3 = 1; D4 = 0; D5 = 1; D6 = 0; D7 for the even parity bit. Status Byte B is defined: D0 = 0; D1 = 0 is a positive weight; D1 = 1 for the negative weight. D2 = 0 normal; D2 = 1 overload. D3 = 0 weighing stability; D3 = 1 weighing were not sure. D4 = 1; D5 = 1; D6 = 0 weight; D6 = 1 POST. D7 for the even parity bit. C status byte ignored.

Weighing Scale. 10key&12key User manual

Weighing Scale. 10key&12key User manual Weighing Scale 10&12 User manual EXCELL PRECISION CO., LTD. 2014. All rights reserved worldwide. The information contained herein is the property of EXCELL PRECISION CO., LTD. and is supplied without liability

More information

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999

More information

SCALE & WEIGHT DISPLAYS

SCALE & WEIGHT DISPLAYS The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters

More information

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630) Vorne Industries 87/719 Analog Input Module User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Introduction... 1.1 Accessing Wiring Connections

More information

Pin setup: 1 (EXC+) 2 (EXC-) 3 (SIG+) 4 (SIG-) Pin setup: 2 (TXD) 3 (RXD) 5 (GND) others (NC)

Pin setup: 1 (EXC+) 2 (EXC-) 3 (SIG+) 4 (SIG-) Pin setup: 2 (TXD) 3 (RXD) 5 (GND) others (NC) Load Cell connection (Male) Pin setup: 1 (EXC+) 2 (EXC-) 3 (SIG+) 4 (SIG-) RS232C Connection: DB-09 (Male) Pin setup: 2 (TXD) 3 (RXD) 5 (GND) others (NC) Bi-directional RS232C Setting Baud Rate The ADC

More information

Set Point Controller OC557. Operator s Manual

Set Point Controller OC557. Operator s Manual OC557_Manual_GB1206D Set Point Controller OC557 4 20mA Input Operator s Manual METRIX ELECTRONICS LTD. Tel: +44 (0)845 034 3234 Minchens Court, Minchens Lane Fax: +44 (0)845 034 3233 Bramley, Tadley, Hampshire

More information

OPERATION MANUAL MODEL DF3000 DIGITAL WEIGHT INDICATOR REVISION A-1

OPERATION MANUAL MODEL DF3000 DIGITAL WEIGHT INDICATOR REVISION A-1 WESTERN SCALE CO. LIMITED OPERATION MANUAL MODEL DF3000 DIGITAL WEIGHT INDICATOR REVISION A-1 Copyright 1994 1670 Kingsway Avenue, Port Coquitlam, B.C. V3C 3Y9. Telephone: (604) 941-3474 Fax: (604) 941-4020

More information

Twin Beam Scale Operation Manual. April Specialists in Industrial Weighing

Twin Beam Scale Operation Manual. April Specialists in Industrial Weighing Twin Beam Scale Operation Manual April 2007 Digi-Tron Specialists in Industrial Weighing www.digitronbalancas.com.br Twin Beam Scale Operation Manual Introduction Dear User, This manual contains operating

More information

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff Ocean Sensor Systems, Inc. Wave Staff III, OSSI-010-008 With 0-5V & RS232 Output and A Self Grounding Coaxial Staff General Description The OSSI-010-008 Wave Staff III is a water level sensor that combines

More information

MS2540 Current Loop Receiver with RS485 Communication

MS2540 Current Loop Receiver with RS485 Communication MS2540 Current Loop Receiver with RS485 Communication User Manual Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358 4202 Fax:

More information

Operators Manual. TeleWeigh Wired. Model: by Fairbanks Scales, Inc All rights reserved Revision 1 09/07

Operators Manual. TeleWeigh Wired. Model: by Fairbanks Scales, Inc All rights reserved Revision 1 09/07 Operators Manual TeleWeigh Wired Model: 27707 2007 by Fairbanks Scales, Inc. 51164 All rights reserved Revision 1 09/07 Amendment Record TeleWeigh Wired Document 51164 Manufactured by Fairbanks Scales

More information

OMEGA SERIES COUNTING SCALE

OMEGA SERIES COUNTING SCALE Operator Manual OMEGA SERIES COUNTING SCALE 2011-2013 by Fairbanks Scales, Inc. All rights reserved 51278 Revision 2 04/2013 Disclaimer Every effort has been made to provide complete and accurate information

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200

More information

Extra long-range RFID (proximity) card reader

Extra long-range RFID (proximity) card reader GP90A Extra long-range RFID (proximity) card reader (1) Features: Extra long reading range of up to 90 cm with ISO-size passive RFID cards*, over 100 cm with special optimized passive cards High-precision

More information

DCP100 Digital Control Programmer Specifications

DCP100 Digital Control Programmer Specifications DCP100 Digital Control Programmer Specifications EN01-6028 October 1996 Overview The DCP100 is a microprocessor based 1 /4 DIN programmer/controller for process variable versus time control of temperature,

More information

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load

More information

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff Ocean Sensor Systems, Inc. Wave Staff, OSSI-010-002F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff General Description The OSSI-010-002E Wave Staff is a water level sensor that

More information

263 Series LED Bargraph Indicator and Controllers

263 Series LED Bargraph Indicator and Controllers 263 Series LED Bargraph Process Control Water Treatment High resolution 51 segment LED Bargraph for easy reading Accuracy 1% Red display Vertical or Horizontal mounting & stackable Connection Diagrams

More information

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Panel cutout required: 1.772 x 3.622 (45mm x 92mm) 1.76 (45mm) 2.45 (62mm) 3.20 (81mm) 3.60 (91mm) 0.59 (15mm) Special Features NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description

More information

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2099-10xx 10MHz Frequency Source April 2014, Rev. H MENU INTERNAL LEVEL = +10dBm MONITOR POWER 1 2 MODEL 2099 FREQUENCY SOURCE CROSS TECHNOLOGIES INC. ALARM OVEN REMOTE EXECUTE

More information

Operator s Manual. Ultegra. Health Scale. Fairbanks Scales by Fairbanks Scales Inc. All rights reserved. Revision 5 06/07

Operator s Manual. Ultegra. Health Scale. Fairbanks Scales by Fairbanks Scales Inc. All rights reserved. Revision 5 06/07 Operator s Manual Ultegra Health Scale Fairbanks Scales 2007 by Fairbanks Scales Inc. All rights reserved 50735 Revision 5 06/07 Amendment Record Ultegra Health Scale 50735 Manufactured by Fairbanks Scales

More information

COMPLETE MANUAL For Personal Scale AV-200-EC-P Baby Scale AV-20-EC Chair Weigher VEH-200-EC.

COMPLETE MANUAL For Personal Scale AV-200-EC-P Baby Scale AV-20-EC Chair Weigher VEH-200-EC. COMPLETE MANUAL For Personal Scale AV-200-EC-P Baby Scale AV-20-EC Chair Weigher VEH-200-EC. All Scales are EC type-approved non-automatic weighing instrument Accuracy class Basically, the Weighing Indicator

More information

Manual Weightbridge PCE-EP Series

Manual Weightbridge PCE-EP Series PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument Installation and Setting up Instructions for the 990 Signal Conditioning Instrument Contents Page 1.0 Overview... 3 2.0 Installation.. 4 2.1 Electrical connections... 4 2.2 Cable selection... 4 2.3 Electrical

More information

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM. VideoJet 8000 8-Channel, MPEG-2 Encoder ARCHITECTURAL AND ENGINEERING SPECIFICATION Section 282313 Closed Circuit Video Surveillance Systems PART 2 PRODUCTS 2.01 MANUFACTURER A. Bosch Security Systems

More information

Model 7000 Model 7000XL

Model 7000 Model 7000XL Model 7000 Model 7000XL Digital Scale INSTRUCTION MANUAL DORAN SCALES, INC. 1315 PARAMOUNT PKWY BATAVIA, IL. 60510 (800)262-6844 FAX: (630)879-0073 MANUAL REVISION : 1.1 SOFTWARE REVISION : 5.0 MAN123-11

More information

APPLICATION NOTE # Monitoring DTMF Digits Transmitted by a Phone

APPLICATION NOTE # Monitoring DTMF Digits Transmitted by a Phone APPLICATION NOTE # Product: 930A Communications Test Set 930i Communications Test Set Monitoring DTMF Digits Transmitted by a Phone Introduction This Application Note describes how to configure and connect

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

OPERATION MANUAL OF MULTIHEAD WEIGHER

OPERATION MANUAL OF MULTIHEAD WEIGHER OPERATION MANUAL OF MULTIHEAD WEIGHER Page 1 of 62 PREFACE Multihead weigher is automatic weighing equipment by using MCU control system to achieve high speed, accuracy and stable performance. Different

More information

USER MANUAL. DV-HSW-41 HDMI 4x1 SWITCHER LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web

USER MANUAL. DV-HSW-41 HDMI 4x1 SWITCHER LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web USER MANUAL DV-HSW-41 HDMI 4x1 SWITCHER 244 Bergen Boulevard, Woodland Park, NJ 07424 Tel 973-785-4347 FAX 973-785-3318 Web www.fsrinc.com LIT1372 PROPRIETARY INFORMATION All information in this manual

More information

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES Programmable DC Source Sink and Source Capability Conventional DC sources usually have the function of power supply (source) only without power absorption (sink) function. In addition to the source function,

More information

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Broadcast Devices, Inc. AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web:

More information

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter.   ACCESSORIES. Technology Solutions Technology Solutions TEK-LCD 7801A NEMA 4X Loop-Powered Feet and Inches Level Meter ACCESSORIES www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The

More information

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S INSTALLATION MANUAL FT-FOTR-1VDE-ST-S 1-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission & Ethernet Transmission v1.0 4/5/11 1 PACKAGE CONTENTS This package

More information

Modbus for SKF IMx and Analyst

Modbus for SKF IMx and Analyst User manual Modbus for SKF IMx and SKF @ptitude Analyst Part No. 32342700-EN Revision A WARNING! - Read this manual before using this product. Failure to follow the instructions and safety precautions

More information

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display AP-34 Separate Amplifier Type Sensor Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display Description Industry's smallest & lightest

More information

Column Type Air Micrometer. CAG2000 Instruction Manual

Column Type Air Micrometer. CAG2000 Instruction Manual Column Type Air Micrometer CAG2000 Instruction Manual Contents 1. Introduction 1 2. Main Features 1 3. Main Modes 2 4. Names and Functions of Controls and Parts 3 5. Specifications 8 6. Measurement 10

More information

Noise Detector ND-1 Operating Manual

Noise Detector ND-1 Operating Manual Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation

More information

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter Broadcast Devices, Inc. AES-404 Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web: www.broadcast-devices.com

More information

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface O P E R A T I O N M A N U A L Version 01/05 RF-Reader Stand-alone-Reader Leser 2plus with RS-232 interface Important! Read by all means! To maintain the perfect shipping conditions and to ensure safe operation

More information

K3NX Process Meter OPERATION MANUAL

K3NX Process Meter OPERATION MANUAL Cat.No. N90 E1 1 K3NX Process Meter OPERATION MANUAL K3NX Process Meter Operation Manual Produced January 1998 Notice: OMRON products are manufactured for use according to proper procedures by a qualified

More information

16-BIT LOAD CELL/DUAL STATUS INPUT

16-BIT LOAD CELL/DUAL STATUS INPUT 16-BIT LOAD CELL/DUAL STATUS INPUT On-board Excitation. +5VDC, (120mA). State-of-the-art Electromagnetic Noise Suppression Circuitry. Ensures signal integrity even in harsh EMC environments. Optional Excitation

More information

WEIGHING INDICATOR SERIE IPE 50

WEIGHING INDICATOR SERIE IPE 50 WEIGHING INDICATOR SERIE IPE 50 Short guide for calibration only see user manual 1/2 for the different functioning mode, analog output and setpoints See user manual 2/2 for special functioning mode and

More information

Wall-/Pipe-Mount Level Indicator

Wall-/Pipe-Mount Level Indicator Data Sheet SS/_4 Wall-/Pipe-Mount Level Indicator High visibility 5-digit LED display clear multi-functional indication Analog and 2-relay outputs as standard high, low, latch and rate alarms, plus isolated

More information

32 Channel CPCI Board User Manual

32 Channel CPCI Board User Manual 0 Sections Page 1.0 Introduction 1 2.0 Unpacking and Inspection 1 3.0 Hardware Configuration 1 4.0 Board Installation 5 5.0 I/O Connections and the Front Panel 5 5.1 Front Panel Layout 5 5.2 Input and

More information

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement A worldwide leader in precision measurement solutions MTI-2100 FOTONIC SENSOR High resolution, non-contact measurement of vibration and displacement MTI-2100 Fotonic TM Sensor Unmatched Resolution and

More information

DSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator.

DSA-1. The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator. DSA-1 The Prism Sound DSA-1 is a hand-held AES/EBU Signal Analyzer and Generator. The DSA-1 is an invaluable trouble-shooting tool for digital audio equipment and installations. It is unique as a handportable,

More information

MT03A Electronic converter for flow rate transmitters

MT03A Electronic converter for flow rate transmitters Instructions manual MT03A Electronic converter for flow rate transmitters The art of measuring R-MI-MT03A Rev.: 0 English version PREFACE Thank you for choosing a Tecfluid S.A product. This instruction

More information

For warranty service, please contact Microframe at: A technician will gladly assist you.

For warranty service, please contact Microframe at: A technician will gladly assist you. Your Microframe System is warranted against failure due to defects in workmanship or material for a period of one (1) year from the date of purchase. Microframe Corporation will repair or replace any defective

More information

Hybrid Chart Recorder 250 mm (10")

Hybrid Chart Recorder 250 mm (10) Hybrid Chart Recorder 250 mm (10") RD5100 Series U High Speed Scanning at 36 Points/Sec and High-Speed Recording U High Accuracy of 0.05% U Various Industrial Values Can be Measured at the Same Time with

More information

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4 UDC100 Universal Digital Controller 51-52-03-29 11/99 Page 1 of 4 Specification Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

Good Laboratory Practices (GLP) Notepad. Automatic Datalogging. Automatic Stability Function. P.I.N. Code Security Access.

Good Laboratory Practices (GLP) Notepad. Automatic Datalogging. Automatic Stability Function. P.I.N. Code Security Access. Good Laboratory Practices (GLP) To comply with GLP guidelines, the date, time and results of the last calibration are stored in memory, along with the instrument s serial number. This data can be displayed

More information

Tutorial on Technical and Performance Benefits of AD719x Family

Tutorial on Technical and Performance Benefits of AD719x Family The World Leader in High Performance Signal Processing Solutions Tutorial on Technical and Performance Benefits of AD719x Family AD7190, AD7191, AD7192, AD7193, AD7194, AD7195 This slide set focuses on

More information

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2016-1250 Downconverter May 2009 Rev A F=2501.750 G=+25.0 MENU MODEL 2016 DOWNCONVERTER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained

More information

User Manual Digital Stroboscope

User Manual Digital Stroboscope Page 15/04/14 V1.0 Table Of Contents 1. Features 3 2. Specifications 3 & 4 2-1 General Specification 3 & 4 2-2 Flash Tube Specification 4 3. Front Panel Description 5 3-1 Flash Tube 5 3-2 Display 5

More information

Package Contents. LED Protocols Supported. Safety Information. Physical Dimensions

Package Contents. LED Protocols Supported. Safety Information. Physical Dimensions Pixel Triton Table of Contents Package Contents... 1 Safety Information... 1 LED Protocols Supported... 1 Physical Dimensions... 1 Software Features... 2 LED Status... 2 Power... 2 Activity LED... 2 Link

More information

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual ORM0022 EHPC210 Universal Controller Operation Manual Revision 1 EHPC210 Universal Controller Operation Manual Associated Documentation... 4 Electrical Interface... 4 Power Supply... 4 Solenoid Outputs...

More information

Electronic converter for level transmitters MT03L Instructions manual

Electronic converter for level transmitters MT03L Instructions manual Electronic converter for level transmitters MT03L Instructions manual R-MI-MT03L Rev.: 1 English version PREFACE Thank you for choosing the MT03L converter from MT03 series of Tecfluid S.A. This instruction

More information

Spectra Batten (Order code: LEDJ95)

Spectra Batten (Order code: LEDJ95) www.prolight.co.uk Spectra Batten (Order code: LEDJ95) Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this equipment away from rain,

More information

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher Kramer Electronics, Ltd. USER MANUAL Model: VS-120 20 x 1 Sequential Video Audio Switcher Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 4 Installing the VS-120 in

More information

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL

ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL UM-TS02 -E026 PROGRAMMABLE CONTROLLER PROSEC T2-series ANALOG I/O MODULES AD268 / DA264 / TC218 USER S MANUAL TOSHIBA CORPORATION Important Information Misuse of this equipment can result in property damage

More information

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999

More information

CARLO GAVAZZI Automation Components

CARLO GAVAZZI Automation Components CARLO GAVAZZI Automation Components UDM 35/40 Digital Panel Meter Programming Guide Index Description 2 Programming Fundamentals 3 Access to Programming Mode/Password Protection 4 Programming 5-18 Inputs

More information

Sensopress LCD Special English

Sensopress LCD Special English Sensopress LCD Special English edition 2-09/2004 - code 5878 1/16 Sensopress LCD with sensor Power Supply Voltage 117 V~ 50 60 Hz 230V~ 50 60 Hz Code TSL00X0100 TSL00Y0100 Consumption 5,5 VA Display LCD

More information

Service Manual. Eclipse Scale Series. Model: PPI-HR5000 HR by Fairbanks Scales Inc. All rights reserved. Issue #8 7/03

Service Manual. Eclipse Scale Series. Model: PPI-HR5000 HR by Fairbanks Scales Inc. All rights reserved. Issue #8 7/03 Service Manual Eclipse Scale Series Model: PPI-HR5000 HR5000 2003 by Fairbanks Scales Inc. All rights reserved 50517 Issue #8 7/03 Amendment Record Eclipse Scale Series PPI-HR5000, HR-5000 50517 / SJ4609

More information

T UNITS Appendix II Setup Functions PRINT FORMAT FORMATTING MINIMUM SAMPLE SIZE FORMATTING MINIMUM ACCURACY...

T UNITS Appendix II Setup Functions PRINT FORMAT FORMATTING MINIMUM SAMPLE SIZE FORMATTING MINIMUM ACCURACY... Table of Contents Introduction... 3 Section One... 5 Installing Your Scale... 5 SETUP... 5 EXPERIMENTATION... 8 Section Two... 9 Understanding Your Scale... 9 KEYBOARD FUNCTIONS... 9 DISPLAY SYMBOLS...

More information

Users guide for PB units Interface unit, 4- or 6-digit

Users guide for PB units Interface unit, 4- or 6-digit Users guide for PB units Interface unit, 4- or 6-digit P s P Nm Status 12/2015 / PBXABXGB.doc Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper use... 3 2.2. Control of the device...

More information

CATALOG NUMBER: HK-MX-VGA-X-Y Product Name

CATALOG NUMBER: HK-MX-VGA-X-Y Product Name Product Name Screen matrix switcher Describe Matrix switcher is a high-performance intelligent matrix switch device designed for switching of audio and video signals. It switches all audio and video input

More information

AS-300D Series Smart Bench Scales Owner s Manual

AS-300D Series Smart Bench Scales Owner s Manual DETE CTO A Division of Cardinal Scale Manufacturing Co. AS-300D Series Smart Bench Scales Owner s Manual 8527-M214-O1 Rev B 01/03 PO BOX 151 WEBB CITY, MO 64870 417-673-4631 Printed in USA INTRODUCTION

More information

R-1580A Microwave Downconverter. Product Brochure

R-1580A Microwave Downconverter. Product Brochure R-1580A Microwave Downconverter Product Brochure Jan 2018 Highlights The DSII Model R-1580A Microwave Downconverter extends the coverage of the R-1550A, or other DSII wide range receivers, to 22 GHz. The

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

Signal Stability Analyser

Signal Stability Analyser Signal Stability Analyser o Real Time Phase or Frequency Display o Real Time Data, Allan Variance and Phase Noise Plots o 1MHz to 65MHz medium resolution (12.5ps) o 5MHz and 10MHz high resolution (50fs)

More information

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701 OWNER S MANUAL PW MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701 ANY CHANGES OR MODIFICATIONS IN CONSTRUCTION OF THIS UNIT DEVICE WHICH IS NOT APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIACE COULD VOID

More information

Display Information Type Backlit blue on white STN Type

Display Information Type Backlit blue on white STN Type Warm Up Time Double the time since last used up to 20 minutes maximum Standard Interface USB Temperature Performance Storage : -5 C to +60 C Operation : 0 C to +50 C Relative Humidity Operation :

More information

16-CH Color Full Duplex Multiplexer Instruction Manual

16-CH Color Full Duplex Multiplexer Instruction Manual 16-CH Color Full Duplex Multiplexer Instruction Manual 707-V1.5(S) Index: 1. Safety Warning 3 2. Introduction 3 3. Features 4 4. Specification 5 5. Front Panel Keypad 6 6. Back Panel Connection 10 7. Menu

More information

4040C COMMUNICATION MODULE

4040C COMMUNICATION MODULE Kokkedal Industripark 4 DK-2980 Kokkedal Denmark info@eilersen.com Tel +45 49 180 100 Fax +45 49 180 200 4040C COMMUNICATION MODULE BIN communication in a 4x40C system Applies for: Program no.: BIN_1LC.130307.0

More information

User s Manual. Log Scale (/LG) GX10/GX20/GP10/GP20/GM10 IM 04L51B01-06EN. 3rd Edition

User s Manual. Log Scale (/LG) GX10/GX20/GP10/GP20/GM10 IM 04L51B01-06EN. 3rd Edition User s Manual Model GX10/GX20/GP10/GP20/GM10 Log Scale (/LG) 3rd Edition Introduction Thank you for purchasing the SMARTDAC+ Series GX10/GX20/GP10/GP20/GM10 (hereafter referred to as the recorder, GX,

More information

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras INSTALLATION MANUAL FT-FOTR-8VD-ST-S 8-Channel Digital Duplex Baseband Transmitter and Receiver With Reverse Transmission for PTZ Cameras v1.0 4/5/11 1 PACKAGE CONTENTS This package contains: One each

More information

GFT Channel Slave Generator

GFT Channel Slave Generator GFT1018 8 Channel Slave Generator Features 8 independent delay channels 1 ps time resolution < 100 ps rms jitter for optical triggered delays 1 second range Electrical or optical output Three trigger modes

More information

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2584-31 Combiner May 2011, Rev. A RF MONITOR GAIN = -15 MENU MODEL 2584 COMBINER CROSS TECHNOLOGIES INC. ALARM REMOTE POWER EXECUTE Data, drawings, and other material contained

More information

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Model KBF P 240 Humidity test chambers with ICH-compliant light source Model KBF P 240 Humidity test chambers with ICH-compliant light source The KBF P humidity test chamber, equipped with ICH-compliant light source, is an expert when it comes to photostability tests and

More information

Quick Operation Guide of LTN7700/7600 Series NVR

Quick Operation Guide of LTN7700/7600 Series NVR Quick Operation Guide of LTN7700/7600 Series NVR UD.6L0202B0042A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable

More information

HK-DID-MXA-VGA-X-Y. Product Name. Describe. Application. Characteristic. Product Model. Screen Matrix Switcher

HK-DID-MXA-VGA-X-Y. Product Name. Describe. Application. Characteristic. Product Model. Screen Matrix Switcher Product Name Screen Matrix Switcher Describe Matrix switcher is a high-performance intelligent matrix switch device designed for switching of audio and video signals. It switches all audio and video input

More information

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor Model CB 60 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor The BINDER CB series CO 2 incubator is the premium class among the CO 2 incubators. It is suitable for all sensitive

More information

Automatic Transfer Switch Control PLC Operator s Manual

Automatic Transfer Switch Control PLC Operator s Manual MTS Power Products MIAMI FL 33142 ATS-22AG Automatic Transfer Switch Control PLC Operator s Manual Dedicated Single Phase Transfer Switch ATS-22AG Automatic Transfer Switch INTRODUCTION 1.1 Preliminary

More information

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function.

Triple RTD. On-board Digital Signal Processor. Linearization RTDs 20 Hz averaged outputs 16-bit precision comparator function. Triple RTD SMART INPUT MODULE State-of-the-art Electromagnetic Noise Suppression Circuitry. Ensures signal integrity even in harsh EMC environments. On-board Digital Signal Processor. Linearization RTDs

More information

M4000 Diagnostic Test System For Power Apparatus Condition Assessment

M4000 Diagnostic Test System For Power Apparatus Condition Assessment Knowledge Is Power SM The World Leader in Diagnostic Test Instruments and Knowledge Services for Electric Power M4000 Diagnostic Test System For Power Apparatus Condition Assessment The world s most advanced

More information

RS Pro SPECTRUM ANALYZER SSA3000X SERIES

RS Pro SPECTRUM ANALYZER SSA3000X SERIES Product Datasheet ENGLISH Stock No: 1236443 (RSSA3021X) 1236444 (RSSA3032X) RS Pro SPECTRUM ANALYZER SSA3000X SERIES Features and Benefits RSSA3032X XX RSSA3021X All-Digital IFTechnology Frequency Range

More information

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control Specifications Model 552 Catalog No. Model Power 55-0665 552 115 VAC, 50-60 Hz 55-0673 552A 230 VAC, 50-60 Hz Input - Single-ended, DC coupled 0 to +10V. Signal source can be Floating (not referenced to

More information

Digital Storage Oscilloscopes 2550 Series

Digital Storage Oscilloscopes 2550 Series Data Sheet Digital Storage Oscilloscopes 2550 Series The 2550 series digital storage oscilloscopes provide high performance and value in 2-channel and 4-channel configurations. With bandwidth from 70 MHz

More information

35058-TE. PLJ-6LED-A LED Frequency Display Module Manual

35058-TE. PLJ-6LED-A LED Frequency Display Module Manual 35058-TE 6-digit LED Frequency Counter Module GREEN DISPLAY LED Frequency Display Module Manual Three Swords Studio Light Rongsheng 2013, March Guangxi Nanning Longan Information including Links and Code

More information

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV MG-XV operating instruction Measuring of norm signals, 4-8-digit Panel instrument type MG-BV Construction instrument type MG-AV Contents 1. Brief description... 3 2. Safety instructions... 3 2.1. Proper

More information

Analogue output module DAO 081

Analogue output module DAO 081 ANALOGUE OUTPUT MODULE DAO 081 Analogue output module DAO 081 for eight ±10 V DC outputs This analogue output module is used for driving components capable of being analogue driven (e.g. proportional pressure

More information

5024 WEIGHING TERMINAL

5024 WEIGHING TERMINAL Kokkedal Industripark 4 DK-2980 Kokkedal Denmark info@eilersen.com Tel +45 49 180 100 Fax +45 49 180 200 5024 WEIGHING TERMINAL Basic system with automatic dosing Applies to: Software: Document no.: STDLIM.140630.1v1

More information

Intelligent Security and Fire Ltd

Intelligent Security and Fire Ltd User Manual Product ranges covered by this manual Vi-P14 Vi-P14A Document Reference Date Firmware Vi-Q4C1 Viq601a.doc 26/11/2009 From Viq001a21 Videoswitch Telephone 01252-851510 Ocean House, Redfields

More information

AD2612 DVB TS SCRAMBLER USER S MANUAL

AD2612 DVB TS SCRAMBLER USER S MANUAL AD2612 DVB TS SCRAMBLER USER S MANUAL CONTENTS 1 SAFETY INSTRUCTIONS ------------------------------------------------------------ 1-1 2 COMPOSITIONS OF SYSTEM AND OPERATING PRINCIPLE----------- 2-1 2.1

More information

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying

More information

OPTICAL POWER METER WITH SMART DETECTOR HEAD

OPTICAL POWER METER WITH SMART DETECTOR HEAD OPTICAL POWER METER WITH SMART DETECTOR HEAD Features Fast response (over 1000 readouts/s) Wavelengths: 440 to 900 nm for visible (VIS) and 800 to 1700 nm for infrared (IR) NIST traceable Built-in attenuator

More information

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X HMS-X_bro_de-en_3607-0181-3X_v0200.indd 1 Product Brochure 02.00 Test & Measurement Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X 15.03.2016 15:24:06 1 Basic Unit + 3 Options Key facts Frequency range: 100

More information

Digital differential Pressure switch Model DPS Instruction manual

Digital differential Pressure switch Model DPS Instruction manual Digital differential Pressure switch Model DPS Instruction manual DPSeng_rev2 September 09 MECAIR S.r.l. Diaphragm Valves and Electronic Controls for Dust Collector Filters Via per Cinisello 97 20054 Nova

More information