AMP CO Plus System Overview & Design Application Guide

Size: px
Start display at page:

Download "AMP CO Plus System Overview & Design Application Guide"

Transcription

1 AMP CO Plus System Overview & Design Application Guide Modern Infrastructures Solutions for the Future A publication of Tyco Electronics

2 Introduction Structured premise cabling systems have become state of the art in modern office buildings. These standard based universal systems have emerged from early proprietary systems. Even in the home networking sector a network is well on the way to become the norm. The corresponding peripheral technology is affordable for a large section of society and DSL technology combined with the Internet provide the motivation for investment. Over the years there have been constant changes to the cabling, the connectors and even the applications. For this reason, standards such as EN for structured premises cabling systems have, to a large extent, ensured planning safety. The first issue in 1995 represented a huge milestone in consolidating the diverse network systems that prevailed at the time and in 2002 the second issue came into force, with several sections having been updated to reflect technology changes and bandwidth requirements. Despite these standards, the requirements of the end user are frequently different, making it increasingly difficult to service these extremely divergent characteristics with standard cabling systems. Therefore, open communication systems always were, and still are, the most suitable connectivity option as they allow the client to take into account technological changes and enable them to adapt to each event. This concept led to the development of the universal AMP CO Plus System, which has now been in widespread use for over 10 years. During this time many improvements and changes have been made to incorporate technical changes into the system. The 10 millionth AMP CO Plus insert was presented at Cebit Gigabit Ethernet over Twisted Pair Cabling is currently occupying the standardisation committees, with the Link classes E and F being redefined and the requirements of the cabling systems increasing. AMP CO already meets these link performance requirements, once again demonstrating its impressive capability and flexibility. Thorsten Punke Dipl. Ing. Marketing Manager EMEA Langen, Germany tpunke@tycoelectronics.com 2

3 Index: 1. Area of Application 4 2. Cabling Standard and 10 Gigabit Ethernet 5 3. Horizontal Cabling 8 4. What is AMP CO Plus? 8 5. Technology and Performance Link Performance Choice of connector interface Application Options Technical performance overview Power over Ethernet Endpoint PSE Mode A Endpoint PSE Mode B Midspan PSE Mode B AMP CO Plus Power Multiplexing Power over Ethernet and ACO Plus PoE Inserts TV Application Technical Facts Use of Preamplifiers CATV receiver units Telephone Application Active port expansion Multiple Service Provision Cost-effectiveness Integration in designer faceplate series Designing with AMP CO Plus Testing Procedure Conclusion Component Guide 49 3

4 Bay Networks Bay Networks Bay Networks 1. Area of Application Structured premises cabling systems are described in the ISO and EN Standard. Two types of topology are mentioned. 1. Centralized Network Architecture 2. Distributed Network Architecture Direct Termination Workstation 90 m for copper cable With fibre from 82m to 5000 m, depending on the fibre quality Workstation Workstation Passive cross connect with fibre Typically cable up to 144 Fibres Cable with 4 fibres Workstation Cable with 4 fibres Workstation Server Pic. 1: CNA (Centralized Network Administration) Centralised cabling is suitable for short link lengths or for entirely fibre optic cabling. Individual users are connected directly or via passive secondary distribution. There is a central communications room where all the cables converge, which also houses all the active equipment. However, in approximately 75 % of the installations a mixed structure is used for a variety of reasons. Twisted pair copper cable is generally used for horizontal cabling from the floor distributors, with fibre optic cable deployed to create a collapsed backbone to these distributors radiating from a centralised building distributor. There are advantages and disadvantages to both types of cabling and it is up to each individual user to weigh up the pros and cons. 4

5 Bay Networks Bay Networks Bay Networks Horizontal cabling Rack with active equipment Copper cable Copper cable Workstation Up to 90m max. with copper cabling Workstation Rack with active equipment Copper cable Copper cable Workstation FO FO Backbone cabling Mostly up to 24 fibres Workstation FO Rack with active equipment Copper cable Copper cable Workstation Server room Workstation WAN/Campus Pic. 2: DNA (Decentralized Network Administration) AMP CO Plus is a cabling system which can be implemented with both topologies and is limited by a length restriction of 90 m for copper cabling. 2. Cabling Standard and 10 Gigabit Ethernet Category 6 in 2002 was the last milestone before the forthcoming Class E A and 10 Gigabit over Copper (IEEE 802.3an) became the next huge step in the Ethernet history. This is again a challenge for a lot of systems and technologies. For the first time the global market recognises the advantage of shielded systems even in IEEE. The existing Class F is one recognised definition which fully supports 10 Gigabit over the 100m without any limitation. As well most of the shielded Category 6 systems will support 10 Gigabit up to 100m, while all category 6 UTP Systems have limitation up to 37m. Because of the increased bandwidth and sensitive coding mechanisms used in communication systems, EMC compliance is a critical design objective for any IT system. For 10 Gigabit Ethernet over copper, EMC compliance is for the first time a challenge and the impact on cabling systems is enormous. 5

6 But why is this? Two key issues influence the 10 Gigabit Ethernet transmission: Alien Crosstalk Background noise Both parameters affect EMC compliance. As the transmission frequency increases, cables and components in a communication channel will disturb each other. It is like NEXT within cable. The worst case is shown in Picture Table 1a: 10G Support of cabling systems IEEE 802.3an 3a. One cable is surrounded by 6 other ones. This configuration is common practice as cables are installed in this way. UTP cabling systems have just one method of protection from electrical disturbance - the twist rate of the pairs. The twist rate is unable to mitigate effectively the interference from adjacent pairs at high frequencies. This is the cause of the major problem for these UTP systems at the required frequencies for the new application. STP systems have an electrical shield, which surrounds each pair and the cable (under the jacket). The shields are able to suppress the electrical interference effectively. This explains the results in Table 1 Pic 3a: EMC comparison STP and UTP environment. The second main issue is background noise. Background noise refers to any electrical interference present in our As the operating frequency of 10 Gigabit Ethernet extends to about 500 MHz, any other application operating within this frequency range is able to disturb the transmission channel. In practice these sources will include: TV stations Radio stations Mobile phone stations 6

7 The cabling systems are able to mitigate some of this electromagnetic noise. The question now is, how much? The indicator is coupling attenuation. This parameter describes the ability of a cabling system to suppress electromagnetic noise. Coupling attenuation is applicable to both shielded and unshielded cabling systems. Pic. 3b: Background Noise Cable Noise dbm/hz Coupling Attenuation Result db Mitigation db Background noise max. db UTP db FTP db STP Cat db -150 db STP Cat db -160 db Table 1b: Calculation of Background Noise Mitigation 10 Gigabit Ethernet was published in June An update of ISO IEC is being developed by the standardisation committees and is planned to be ratified in Because of the required bandwidth requirements, two new link classes are expected to be added to the existing ones as follows: Class E A Class F A 500 MHz 1000 MHz AMP Netconnect has already the AMP CO Plus System tested for the new link classes by independent test laboratories. AMP CO Plus already meets the requirements for both new link classes. Even the new Class F A with a bandwidth of 1000 MHz has been successfully tested by GHMT, 3 rd party lab. This once more demonstrates the future potential of the system. 7

8 3. Horizontal Cabling Typical horizontal cabling describes the infrastructure from the floor distributor to the wall outlet. Conventional cabling systems are firmly connected to a jack or a wall outlet. All cables are normally terminated in the patch panel. The RJ 45 connector interface is used and the cable and connector impedance is 100 Ω nominal. However, this has not always been the case, with other connector interfaces on the market including 93 and 150 Ω. Furthermore not all services use all pairs. In addition, the link class must be established regardless of further technical changes, which may arise in the future. Standard systems are unable to respond to these changes. Only open communication systems are in a position to respond to these changes. This is the main characteristic of the AMP CO Plus System. 4. What is AMP CO Plus? Pic. 4: Principle of AMP CO Plus The most striking difference between the AMP CO Plus System and standard systems is that the communication interface is variable. The cable is terminated at the edge connector (see page 10), which constitutes an open communication interface on both ends. The application is then determined by the adapter insert which provides many benefits for the user and networking administrator. This design enables the cable to be used in different ways. This type of connection conforms to all relevant standards as all 8 conductors are terminated. The edge connector is used in the patch panel and wall outlet 8

9 Pic. 5: Terminated cable on the edge connector in an AMP CO Plus outlet The application determines the adapter, which has to be used. The ISO 11801/EN Standard specifically refers to the possibility of changing the service by changing the inserts. A range of inserts is available which provide a number of different application options. In standard systems the cable is fixed and connected to the jack. This means that it is not possible to make changes, with the component quality e.g. category and link class also being fixed. Pic. 6a: conventional outlet Pic. 6b: conventional jack 9

10 5. Technology and Performance This flexible design offers many advantages compared with standard systems. At the heart of the system lies the edge connector Mark ll, to which the cable is terminated. In addition to full shielding, the edge connector also has PiMF Management, ensuring all foil pairs are individually separated and shielded from each other. Pic. 7: Shielded edge connector The performance of the Mark II far exceeds all category requirements and offers huge potential for future developments. Lab tests show a performance up to 2GHz. Given a future definition of 1000 MHz for link class F and the fact that even developments such as 10 Gigabit Ethernet over copper do not require a higher link class, there is clearly sufficient reserve available. Pic. 8: PiMF Management NEXT Loss performance of shielded edge connector up to 2 GHz db Limit P1&P2 P2&P3 P3&P Freq (MHz) Pic. 9: Nextperformance 10

11 6. Link Performance The design of the AMP CO Plus System, as detailed above, enables all link classes to be installed without the need to specify connectors. Pic. 10a: Link performance of the AMP CO Plus System In general practice today, a 600 MHz PiMF cable is most frequently used, however the use of a 1200 MHz cable is recommended. The cable is connected at each end to the edge connector providing a link up to class F. As well the forthcoming Class F A with 1000 MHz is recognised. The most important point is the cable. As higher the bandwidth is, as longer the system can be used. The best available cable is a PimF 1200 MHz AWG 22. This cable provides best technical performance on the market as well as excellent CATV conditions. Reason is a very low attenuation, the most limiting factor for CATV transmissions up to 100m. See page 30 for more information. Since as yet no data application requires this bandwidth, a category 5E insert can be used, resulting in a class D link with 10/100/1000 MBit Ethernet application support. Then, when a higher link class is needed, the system can be upgraded to either link class E, E A, F and F A. Further configurations and options can be found on the following pages. Remember: There is no substitute for bandwidth, except more bandwidth. Pic 10b: History of speed and bandwidth 11

12 7. Choice of connector interface The fact that two connector interfaces are standardized for link class F in the EN Standard shows how important this choice is. A TERA insert is already available for the AMP CO Plus System. Pic. 11: TERA TM Insert AMP CO Plus users have a completely independent choice of which connector interface to use, when to use them and for what application. As well as standard RJ 45 inserts in both single and double variants, it is also possible to operate CATV and D-sub9 inserts as well. Pic. 12: Triple Insert CATV/Ethernet/Telephone The AMP CO System exploits the fact that many services only use 2 of the 4 available pairs, so either a fully loaded single insert or an application specific dual insert can be used. This makes the system very flexible and economic because of the different utilization. A look back in time, to when modern data system were conceived, will show just how important this flexibility is. In addition to various RJ 45 connector interfaces, IBM and BNC connectors, there were also different impedance environments from 93 Ω to 150 Ω that required impedance matching. Pic. 13: Sub D9 Insert This feature is used in the CATV insert, which has an impedance match from 100 Ω to 75 Ω. The need for awkward and susceptible external converters can be avoided by changing the insert with integrated impedance matching. The AMP CO system has always enabled all environments to be supported over a single network infrastructure. Pic. 14: RJ 45 Insert 12

13 8. Application Options Many different applications can be supported. Pic. 15: Different Inserts Application Scenarios: On the following pages you will find examples of possible configurations. The colour blue denotes an alternative configuration. The cable length is dependent on the respective link length. The number of wall outlets determines the number of patch panels. In chapter 19 you will find concrete examples of designs with some case studies. Note: The following examples based on DIN Outlets and RAL 7035 patch panels. In case of another installation environment, please check the EMEA catalogue or page in this book. 13

14 Scenario 1: 2 cables per work area This scenario is frequently found, as it is possible to use the triple insert for one link. In addition to telephone and fax connections, an Ethernet or fast Ethernet connection can be made. The remaining outlet is provided with a blind insert and can be activated for future applications. Pic. 16: Configuration with Triple Insert and Blind Insert PN Description Number Application Cable PiMF 600 MHz - Y X Straight Wall Outlet X Triple Insert X Blind Insert 1 Y X Patch Panel, 16 Port RAL Y X Angled Wall Outlet Cable PiMF 1200 MHz - Y X Patch Panel, 24 Port RAL Y and X denotes colour or configuration choice Ethernet, telephone, fax + 1x reserve 14

15 Scenario 2: 2 cables per work area Another option is to use one dual and one blind insert. This configuration is adequate in many cases and ensures cost effective use of cables. Pic. 17: 2 Cables with Dual Insert and Blind Insert PN Description Number Application Cable PiMF 600 MHz - Y X Straight Wall Outlet X Dual Insert X Blind Insert 1 Y X Patch Panel, 16 Port RAL Y X Angled Wall Outlet Cable PiMF 1200 MHz - Y X Patch Panel, 24 Port RAL Y and X denotes colour or configuration choice Ethernet, telephone or fax + reserve 15

16 Scenario 3: Extending the reserve port One possible future scenario is that one user will require Gigabit Ethernet. According to the current transmission definition, this protocol uses all 4 pairs. Pic. 18: 2 cables with single and Dual Insert PN Description Number Application Cable PiMF 600 MHz - Y X Straight Wall Outlet X Dual Insert X XG Insert 1 Y X Patch Panel, 16 Port RAL Y X Angled Wall Outlet Cable PiMF 1200 MHz - Y X Patch Panel, 24 Port RAL Y and X denotes colour or configuration choice Ethernet, telephone or fax + reserve By simply inserting the adapter, the link is fully wired and activated. This option is very economical, since the migration towards Gigabit Ethernet occurs slowly. The use of Gigabit Ethernet in the work area demands powerful backbone and/or campus cabling, which must be upgraded first in many cases. 16

17 Scenario 4: 2 cables per work area with CATV service Pic.19: 2 Cables with Dual Insert and CATV Insert PN Description Number Application Cable PiMF 600 MHz - Y X Straight Wall Outlet X CATV / RJ45 / Telephone Insert X Blind Insert 1 Y X Patch Panel, 16 Port RAL Y X Angled Wall Outlet Cable PiMF 1200 MHz - Y X Patch Panel, 24 Port RAL Y and X denotes colour or configuration choice Ethernet, telephone or fax+ CATV 17

18 Scenario 5: 2 Cables per work area with CATV service and Ethernet Pic. 20: 2 cables with dual insert and CATV / RJ45 insert The maximum extension level demonstrates the system s enormous potential. By extending the second port, other services can be used in addition to CATV. PN Description Number Application Cable PiMF 600 MHz - Y X Straight Wall Outlet X Dual Insert X CATV / RJ45 / Telephone Insert 1 Y X Patch Panel, 16 Port RAL Y X Angled Wall Outlet Cable PiMF 1200 MHz - Y X Patch Panel, 24 Port RAL Y and X denotes colour or configuration choice 2x Ethernet, Telephone, or FAX or Ethernet+ CATV 18

19 Scenario 6: 3 cables per work area As well with three cables some efficient configurations are possible. Three cables are commonly used in a double work area or a work zone. Then this efficient configuration can be used, giving a clear demonstration of the benefits of the system. Pic. 21: 3 cables with Dual Insert and 4x Telephone Insert PN Description Number Application Cable PiMF 600 MHz - Y X Straight Wall Outlet X Dual Insert X 4x Telephone Insert 1 Y X Patch Panel, 16 Port RAL Y X Angled Wall Outlet Cable PiMF 1200 MHz - Y X Patch Panel, 24 Port RAL Y and X denotes colour or configuration choice Ethernet, telephone or fax+ reserve 19

20 Comparison: AMP CO Plus and a conventional cabling system Only 3 cables are used instead of 8. As a result, there is more room in the pathways and considerably less fire protection is required making it more economical. Additionally there is also less cable to lay and terminate; a clear demonstration of one of the many financial advantages of the AMP CO Plus System. Pic. 22a: Comparison AMP CO Plus/Conventional cabling 20

21 9. Technical performance overview The following summary shows what options the system has to offer. It also clearly demonstrates that the installed link is the constant, whilst the adapter insert represents the variable, thereby making all link classes from D to F possible. Class G refers to 1200 MHz non standard solution. Trends and technologies come and go and the only certainty is that they will keep on changing. Pic. 22b: Performance overview AMP CO Plus will help to manage change, growing with each specific demand in your organization. Best example is the current Class E A and F A definition driven by 10 Gigabit Ethernet. While AMP CO fully supports all present definitions of both classes (page 7), all existing UTP systems do not support 10 Gigabit up to 100m. 21

22 10. Power over Ethernet Power over Ethernet (PoE) is one of the latest technologies that will quickly penetrate the market and will be of major consideration for network designers and planners in the future. PoE means that power (energy) as well as data is supplied by the twisted pair data line. The exact specification allows for 48 V (57 V max.) at maximum 15,4 Watts. The IEEE has produced the 802.3af standard for PoE, in which three different options for deploying PoE are defined: Endpoint PSE Mode A Endpoint PSE Mode B Midspan PSE Mode B 10.1 Endpoint PSE Mode A In this mode the operating voltage is supplied over data pairs 1,2 and 3,6. This mode is also known as phantom powering and is the required mode for services that do not provide any spare pairs (i.e. Gigabit Ethernet). The same applies with the double inserts for the ACO System. For example if Ethernet and ISDN are transmitted over the same cable, there are no spare pairs available. This is then the only mode that permits the data and power supply to be operated simultaneously. Pic. 23: Power over Ethernet, Mode A 802.3af 22

23 10.2 Endpoint PSE Mode B In this mode the operating voltage is supplied over the spare pairs (i.e. pairs 4,5 and 7,8). The power supply is energised directly by the switch. Pic. 24: Power over Ethernet Mode B 802.3af 10.3 Midspan PSE Mode B This mode also uses the spare pairs, but the power is fed via an additional Midspan Unit. This is a good alternative for existing cable plants during the transitional period. It is however anticipated that future switches will be fitted with a PoE function. As a result, Endpoint PSE Mode A will play an increasingly important role. Pic. 25: Power over Ethernet Modus B Midspan 802.3af 23

24 AMP Netconnect has developed external Midspan power units in accordance to IEEE 802.3af. The units has some additional beneficial features: o o o o o Fully compliant to IEEE 802.3af Full power (15,4 Watt on each port) 8 port modular construction Supports 1000 Base-T Controlled and low heating radiation Because of the modular construction, the user is able to upgrade step by step as network demands grow. See page 36 for more information s. For bigger installations AMP Netconnect offers a 24 port Midspan with SNMP support. As well as the 8 port unit, all ports are fully powered with 15,4 Watt. 24

25 11. AMP CO Plus Power Multiplexing What is AMP CO Plus Power Multiplexing? A closer look at the various modes shows that: If the user uses a dual insert, there are no unused pairs as all 4 pairs are used. Consequently it is not possible to operate PSE B. The Midspan Mode also uses the unused pairs, so that is not suitable either. Therefore: only Mode A will work. Important: This statement only applies to the use of dual AMP CO Plus inserts. When single inserts are used, the system is fully wired. Pic. 26: AMP CO Power Mulitplexing Why the PoE insert? This insert ensures that the power is modulated to pairs 1,2 and 3,6 enabling the other pair to be used for data and power. The insert ensures that an operating mode compliant with IEEE af is achieved, if the source powers on Mode B. Advice for Cisco users: Cisco uses pairs 1,2 and 3,6 in non-compliant terminals. Therefore the dual Ethernet inserts can be used. Recommendation: AMP Netconnect supplies inserts with the PoE labelling so that it is always clear whether there is a PoE function or not, especially in the user work area. Most sources power with Mode A, hence there is no need for this insert. 25

26 12. Power over Ethernet and ACO Plus PoE Inserts With ACO and PoE inserts all terminals can be operated in compliance with IEEE af. The configuration is for Mode A and B as follows: Switch (with PoE) ACO Patch Panel (PoE Patch Panel Insert) Link Wall outlet (PoE Outlet Insert) Pic. 27: Configuration Switch with Power Function 26

27 The configuration is for Mode B Midspan as follows: Switch (without PoE) PoE Midspan Unit ACO Patch Panel (PoE Patch Panel Insert) Link Wall outlet (PoE Outlet Insert) This type of network equipment is still not widely available and if the switches are still very new, the Midspan Mode offers the best solution in financial terms. This enables the use of the existing hardware and it is easy to provide users with Power over Ethernet. Pic. 28: Configuration with an external Midspan Unit (Mode B Midpsan) 27

28 13. TV Application An insert for video and TV applications is available for the structured premises cabling for the AMP CO Plus System. These inserts allow video signals from surveillance cameras and video recorders as well as analogue and digital television and radio channels up to the frequency band of 862 MHz to be transmitted over the structured premises cabling (Twisted Pair). Pic. 29: Triple Insert with CATV Interface The F connector used in the insert is well known in the field of satellite technology and has very good transmission properties up to approx. 2 GHz. Impedance matching of 75 Ohm (coax) to 100 Ohm (Twisted Pair) is produced in the AMP CO insert. The following frequency bands are available for distributing TV signals for cable and terrestrial systems: Band Description Frequency range Application Medium VHF I VHF Band I MHz TV Terrestrial and cable VHF II VHF Band II 87,5-108 MHz Radio Terrestrial and cable USB Midband MHz Radio Terrestrial and cable USB Midband MHz TV Terrestrial and cable VHF III VHF Band III MHz TV Terrestrial and cable OSB Superband MHz TV Terrestrial and cable ESB Hyperband MHz TV/Radio Terrestrial and cable UHF I UHF Band I MHz TV Terrestrial and cable UHF II UHF Band II MHz DVB Cable For reasons of economy, most channels transmitting over the cable broadband network are below 450 MHz and terrestrial channels are below 600 MHz. Frequencies below 41 MHz can not be transmitted! 13.1 Technical Facts In TV engineering transmitters normally work with output signals of 75dBµV whilst receivers need a signal of 55dBµV for perfect reconstruction. This means that the attenuation of the link shall not exceed 20 db. Consequently for a purely passive link supporting a bandwidth of 862 MHz the maximum link length should not exceed approx. 25 meter, for a bandwidth of 28

29 600 MHz approx. 40 meter and for a bandwidth of 450 MHz 50 Meter for 600 MHz (Cat. 7) cables Use of Preamplifiers In order to increase the maximum range in a specific frequency band, preamplifiers with equalisation adjustment can be installed in a TV system to balance the attenuation (Pic 30). In view of the maximum permitted signal amplitude of 105 dbµv, standard signal amplifiers with a gain of up to 30 db can be used in the patch panel. This increases the link length in the frequency band up to 862 MHz to approx. 80 meters. The link length up to 600 MHz and Attenuation db -40 Att 15m Att 90m Freq (MHz) Pic.30: Attenuation of links with TV-inserts (PiMF 600 and 2 inserts ) below is 90 meters in the horizontal premises area, which is the maximum length as per EN Illustration 30 shows the attenuation of a TV link in relation to the frequency and length. It is clear that the attenuation increases as the frequency and length increases (90 meter link purple, 15 meter link blue). Without preamplifier attenuation With preamplifier Gain Frequency band Insert cable max. length amplifier cable max. length up to 450 MHz 1,9 db 16 db 50 m 20 db 42 db 90 m* up to 600 MHz 2,5 db 15 db 40 m 20 db 45 db 90 m up to 862 MHz 3,3 db 14 db 25 m 30 db 44 db 80 m *restricted by the maximum permitted length of a permanent link in accordance with EN

30 13.3 CATV receiver units The permitted input levels of the receiver units shall be not exceeded. On the receiver side signals should lie within the window from 55dbµV to 72dBµV. Values above or below can have a negative impact on transmission quality. Below 55dBµV the signal is unfavourable in terms of the signal-to-noise ratio (S/N ratio) whilst above 72 dbµv saturation effects can occur. CATV Channel Calculator for Cat 7 cable OK NOT OK Frequency (MHz) Band VHF I-II VHF III Superband Hyperband UHF I UHF II Signal IN (dbµv) (signal strength as has to be delivered by carrier) CATV OUT (MIN dbµv) CATV OUT (MAX dbµv) (signal strength required by TV set) Attenuation Connectors (db) 0,57 0,82 0,92 1,16 1,31 1,71 (insertion loss of AMP CO CATV insert) Attenuation Patchcords 1.5m (db) 0,68 0,68 0,68 0,68 0,68 0,68 (insertion loss of CATV patchcords) Attenuation Cable 15m (db) 1,93 4,44 5,13 6,56 7,39 9,22 Attenuation Cable 30m (db) 3,85 8,88 10,26 13,12 14,78 18,44 Attenuation Cable 45m (db) 5,78 13,33 15,38 19,68 22,16 27,66 Attenuation Cable 60m (db) 7,70 17,77 20,51 26,24 29,55 36,88 Attenuation Cable 75m (db) 9,63 22,21 25,64 32,80 36,94 46,11 Attenuation Cable 90m (db) 11,56 26,65 30,77 39,36 44,33 55,33 (insertion loss of Cat 7cable per length) w/o Amplifier Output 15m (db) 60,58 57,55 56,67 54,76 53,62 51,01 Output 30m (db) 58,66 53,11 51,54 48,20 46,23 41,78 Output 45m (db) 56,73 48,67 46,42 41,64 38,85 32,56 Output 60m (db) 54,80 44,23 41,29 35,08 31,46 23,34 Output 75m (db) 52,88 39,79 36,16 28,52 24,07 14,12 Output 90m (db) 50,95 35,35 31,03 21,96 16,68 4,90 (signal output w/o amplifier) Linear Amplifier +12 db Output 15m (db) 72,58 69,55 68,67 66,76 65,62 63,01 Output 30m (db) 70,66 65,11 63,54 60,20 58,23 53,78 Output 45m (db) 68,73 60,67 58,42 53,64 50,85 44,56 Output 60m (db) 66,80 56,23 53,29 47,08 43,46 35,34 Output 75m (db) 64,88 51,79 48,16 40,52 36,07 26,12 Output 90m (db) 62,95 47,35 43,03 33,96 28,68 16,90 (signal output with linear amplifier low) Linear Amplifier +20 db Output 15m (db) 80,58 77,55 76,67 74,76 73,62 71,01 Output 30m (db) 78,66 73,11 71,54 68,20 66,23 61,78 Output 45m (db) 76,73 68,67 66,42 61,64 58,85 52,56 Output 60m (db) 74,80 64,23 61,29 55,08 51,46 43,34 Output 75m (db) 72,88 59,79 56,16 48,52 44,07 34,12 Output 90m (db) 70,95 55,35 51,03 41,96 36,68 24,90 (signal output with linear amplifier high) Variable Amplifier +30 db Output 15m (db) 70,58 70,55 73,67 77,76 79,62 81,01 Output 30m (db) 68,66 66,11 68,54 71,20 72,23 71,78 Output 45m (db) 66,73 61,67 63,42 64,64 64,85 62,56 Output 60m (db) 64,80 57,23 58,29 58,08 57,46 53,34 Output 75m (db) 62,88 52,79 53,16 51,52 50,07 44,12 Output 90m (db) 60,95 48,35 48,03 44,96 42,68 34,90 (signal output with variable amplifier) Note: This table is an indicator. The length can differ in praxis depending on physical conditions. 30

31 14. Telephone Application Today every typical work area is equipped with a telephone in addition to the data port. Three different technologies are available Analogue Digital (ISDN) VoIP Various inserts are available for the analogue and ISDN applications. Analogue Pic. 31: 2x Analogue Telephone A double insert can certainly be used here in order to run two telephones from one cable, thereby saving one cable. PN Description Number Application Cable PiMF 600 MHz - Y X Straight Wall Outlet X Dual Insert 1 Y X Patch Panel, 16 Port RAL Y X Angled Wall Outlet Cable PiMF 1200 MHz - Y X Patch Panel, 24 Port RAL Y and X denotes colour or configuration choice 2x telephone pin assignment 4,5 + 4,5 31

32 Pic. 32: 4 x Analogue Telephone Using the 4x insert is the most economical solution. PN Description Number Application Cable PiMF 600 MHz - Y X Straight Wall Outlet X 4x telephone Insert 1 Y X Patch Panel, 16 Port RAL Y X Angled Wall Outlet Cable PiMF 1200 MHz - Y X Patch Panel, 24 Port RAL Y and X denotes colour or configuration choice 4x analogue telephone Pin assignment: 4 x 4,5 This insert must also be used in the patch panel located in the floor distributor where the telephony services are distributed from, as well in the wall outlet. Therefore 4 telephones can be run from a single cable. This arrangement is very economical for planning working areas, where several users are found. Unlike a standard cabling system, which would require 4 cables, the AMP CO Plus System needs only one. See the example on page

33 ISDN S 0 Bus Pic. 33: Principle ISDN S 0 Bus ISDN basically requires 4 wires and can be regarded as a bus. Pic. 34: 2 x ISDN with terminal resistor The simple model uses a dual insert. This is fitted with the 100 Ω terminal resistors, which are required by definition. PN Description Number Application Cable PiMF 600 MHz - Y X Straight Wall Outlet X Dual ISDN Insert X Blind Insert 1 Y X Patch Panel, 16 Port RAL Y X Angled Wall Outlet Cable PiMF 1200 MHz - Y X Patch Panel, 24 Port RAL Y and X denotes colour or configuration choice 2x ISDN with terminal resistor 33

34 A 4x insert is also available, as for the analogue telephone, enabling 4 ISDN devices to be run from a single cable. Pic. 35: 4x ISDN Telephone PN Description Number Application Cable PiMF 600 MHz - 4 x ISDN Y X Straight Wall Outlet X 4x ISDN insert X Blind cover 1 Y X Patch panel, 16 Port RAL Y X Angled Wall Outlet Cable PiMF 1200 MHz - Y X Patch Panel, 24 Port RAL In this case 2x ISDN S 0 buses are fed on the panel side. On the wall outlet side there are then 2 ports available for each S 0 Bus. Since the basic version of ISDN offers 2 active channels, 4 terminals can be operated independently. This means that the cable is fully occupied, making it considerably more economical than standard cabling, which uses one cable per telephone. The terminal resistors are already fitted in this configuration too. Pic. 36: Comparison AMP CO Plus telephone application/conventional telephone application 34

35 15. Active port expansion Another key feature of the AMP CO Plus system is the outlet switch. This is plugged into the wall outlet in the place of an insert, thereby extending the connection by three switched ports. The ports offer either 10/100 or 1000 MBit/s. The switch controls the speed by auto sensing. The power is supplied via the Midspan Unit, which can of course also be used for other terminals. An example of an AMP Netconnect solution will be shown on the next page. The switch is an IEEE af compatible device and ready for immediate use. This is a very efficient and fast way to extend the ports. Pic. 37: Configuration Outlet Switch with Midspan Unit (Mode B Midpsan) Pic. 38: Gigabit Ethernet Outlet Switch 35

36 Midspan Power Unit As mentioned on page 24, IEEE has defined in af as one of the modes an external Midspan Power Mode. An external solution is a great opportunity to extend the value of the existing hardware as it saves on investing in additional switches. Another good reason is the fact that the power supply and the data ports are separated. With a defined maximum of 15,4 Watt on each port, the heat dissipation is separated which may prevent some heating problems in the rack. Problems can occur within some installations if the power supply is included in the switch. If the space is limited and the rack is full, a hot spot can occur. AMP Netconnect has developed a modular solution, so the customer is able to migrate step by step as and when needed. Additionally, the modules are standardized to provide 10/100 Mbit as well 1000 Mbit/s in the auto sense mode. Even though most of the applications will use 10 or 100 Mbit/s, the option for 1000 Mbit/s is a great future proofing feature. Pic. 39: Tyco Midspan Power Unit As already mentioned above, the maximum power output is defined at 15,4 Watts per port. AMP Netconnect provides full power on all ports. All modules can be mounted in a 19-inch 1U panel. Maintenance updates, additions or changes can be done easily. A good example is the scenario shown on page 35. The outlet switch is receiving power over the data line from the Midpsan Unit. The market for remote powered devices will increase within the next years. IP cameras, IP telephones and W-LAN access points are only the start. The modular solution can grow with individual customer's specific demands and will help to keep costs down. Detailed product information can be downloaded from the web site. 36

37 16. Multiple Service Provision Twisted pair cabling systems transmit information to support different services. Each cable consists of 4 pairs. The services utilize the cables in different ways. For example, an analogue telephone needs only one pair, whilst Gigabit Ethernet requires all four. Many services use two pairs. Service Ethernet Fast Ethernet Gigabit Ethernet ISDN Analogue telephone CATV 1 pair 2 pairs 4 pairs X X X X X X As a rule of the cabling standard the jack/connector can accommodate 8 wires. This makes sense, since it ensures that services such as Gigabit Ethernet can be operated. In practice, however, 2-pair services are generally used and consequently a range of different configurations can be found. A pair assignment is given to each service. Service PINs 1,2 Pins 3,6 Pins 4,5 Pins 7,8 Ethernet X X Fast Ethernet X X Gigabit Ethernet X X X X ISDN S 0 X X Analogue telephone X CATV X Thanks to its modular design and the use of inserts, AMP CO Plus offers the freedom of choice. The decision-making occurs in the selection of the inserts, since this is where the pairs are allocated to the correct contacts in the RJ 45 jack. 37

38 Pic. 40: Principle sheath sharing It is useful to know that each correct pin assignment will be done in the insert. In theory then, virtually any combination is possible to deliver a wide range of services to a single work area. The example above is very common because it is so easy to provide two networks services with one cable. As Fast Ethernet is defined on pairs 1,2 and 3,6 the correct assignment is provided by the Fast Ethernet Dual Insert. 38

39 Pic. 41: Sheath sharing with Ethernet and Telephone Fast Ethernet and telephone is another favourite combination. This corresponds to a basic configuration in almost all work areas. Fast Ethernet and telephone is another favourite combination. This corresponds to a basic configuration in almost all work areas today. The AMP CO Plus System offers a variety of options. In addition to the dual inserts, triple and quad inserts are also available. Accordingly optimum economy can be achieved every time. 39

40 Standard systems only make use of one part of the cable. Since a very inhomogeneous terminal culture prevails in many environments, only a small percentage of the cable is fully used throughout the world. In other words, approx. 90% of the cable is used to only 50% of their capacity! Even if the numbers of terminals increase, using the cable to 100% capacity, there still remains a huge unused potential. With AMP CO Plus the infrastructures can always be used to full capacity. 17. Cost-effectiveness The cost-effectiveness of every investment must be scrutinized and the following points taken into consideration. Lifetime of the equipment Amount of investment Additional cost of modifications/secondary cost Utilization of the potential It is worth that frequently only the one-off investment costs are taken into consideration. In fact in many cases only the material cost of the initial investment is considered. Consequently, what at first appears to be a good investment can in the end turn out to be more costly. A good example is 10 Gigabit Ethernet. A lot of existing Cat. 6 cabling systems are unable to support this. A re-cabling is necessary. AMP CO Plus is ready now without any modification. The serviceable life of the equipment varies, but can be up to a maximum of 10 year. And this is where AMP CO Plus has the advantage. There are two financial advantages compared with standard systems: In the initial investment: Less cables Less space required in the cable trays, so the cable ducts can be smaller Less fire-proofing and fire load No ANEXT testing necessary therefore fully 10G certification Long-term: Adaptation to new technologies and new standard compliant connector interfaces Adaptation to higher bandwidth requirements No costly re-cabling required The key aspect here is the freedom of choice! 40

41 There is no need to decide immediately whether a complete Class F installation is necessary, or indeed to choose the interface, as the user can make these decisions at a later date. In this particular example, two connector interfaces are standardised for class F link performance. (See page 12). Pic. 42: Comparison UTP and STP Cables Here too selective insert choice also has the advantage that it is only necessary to activate those ports that are going to be used. This is the case if an upgrade from Cat.6 to Cat. 7 is necessary or when some users have a specific demand. Users of the AMP CO Plus System can take their time and make the investment selectively if necessary. With conventional systems on the other hand, complete panels and wall outlets have to be changed. History shows that this was the case in 2000, when Gigabit Ethernet was ratified. The same will happen for 10 Gigabit Ethernet, since most of existing Cat. 6 systems will not support this. Finally conventional systems have to be re-certified. This is not necessary with the AMP CO System. Cable trays and fireproofing When designing cable networks the designer must calculate the correct size of the cable trays and ducts or the corresponding space in the raised floor. Many cables can rapidly accumulate here and in recent years the cables have been getting thicker and thicker. A PiMF 600 MHz cable is with 7,3 mm even now lower in diameter then the newest generation of UTP cables with approx. 7.8 mm and a 1200 MHz cable now has a diameter of 8,1 mm, so it is critical to provide adequate dimensioning of cable pathway systems. AMP CO Plus helps to keep the fill ratio at a minimum. The fire sealing is applied in the openings between two parts of a building. The more cable there is, the larger the opening and therefore the more fire-proofing required. Positive side effect: The overall potential fire load is reduced at the same time. Pic. 43: Comparison 30 to 15 cables in a cable duct If you start with 3 cables for 1-2 work areas, as outlined in the example on pages 20-21, the same number of ports would be achieved with 8 cables in standard systems. 41

42 With reference to picture 43, 5 complete areas could be equipped with the 15 cables. In standard systems 40 cables would be needed, that is 10 more than in the lower cable channel in illustration 41. In installations with several hundred connection points, it is easy to see how full the channels become. With 10 Gigabit Ethernet a new important point has to be considered: Complete certification on the side for the forthcoming Class E A and F A. This means particular ANEXT and AFEXT testing. This is in the filed not possible, as each potential victim cable has to be known and secondly 6 additional testes are necessary. All shielded systems as well AMP CO fulfil those requirements by design. There is no additional testing necessary. Certification can be done as today. Pic. 44a: The real world, where is the victim? There are economic benefits of up to 30%. Right from the beginning the investment is smaller with AMP CO Plus than with a standard system, due to the reduced quantities of cable and secondary costs such as cable path ways, fireproofing and certification costs. This also emerged in the comparison of systems described on page 41. At the same time, the serviceable life of the system is of course longer, without the need for expensive re-cabling projects. Pic. 44b: Lifetime of different systems 42

43 18. Integration in designer faceplate series Today s users often choose a designer faceplate series, which can be selected to match the interior of the room or building. It is important to ensure that the respective range is fully compatible with the communication outlets. As a result of years of working in cooperation with the faceplate industry, a solution for the AMP CO System is available in most cases. A matching insert is generally available for the chosen range for inclusion in the installation kit. On the website at you will find an AMP CO Plus configurator for DIN style environment which are standard on the German and Austrian markets, but is often used in many other markets. In addition there are solutions for EDIZIOdue, which is applicable for the Swiss market. The French market is served with the Mosaic solution. For the Australian and New Zealand markets, appropriate faceplates (Clipsal 2 nd series etc.) are also available. Note: In any case of uncertainty, please contact your local sales office in the respective country. See page 60 for details. Solutions are also available for the under floor area, where kits are compatible with most of current solutions and providers in the market. This guarantees that the product is compatible with most of the current designer faceplate series. 43

44 19. Designing with AMP CO Plus Designing with AMP CO Plus is different from standard systems. There are some specifics, which you need to be bear in mind. A summary of the most important are: One cable must be connected to each outlet A link (outlet-panel) contains always the same inserts (except the telephone) Certification always takes place with the single insert Example I A new building with 200 work areas is to be constructed. There will be 3 cables per work area. A data/telephone connection and a fully wired insert will be installed in each work area. The third outlet will be reserved for future applications and fitted with a blank insert. It is assumed that a 1200 MHz cable (AWG22) and an average cable length of 60 m will be installed. Angled wall outlets are used, colour RAL The floor distributor will house a 16-port panel. This gives the following: 44

45 Position Product Order Number Quantity 1 PiMF cable, AWG 22, 1200 MHz m 2 Patch Panel, 16 Port items 3 Angled Wall Outlet items 4 2x Insert Data/Telephone Cat items 5 1x Insert, Universal, Cat items 6 Blank Insert items 7 1x Single Insert (for certification) items Example II A new building for 750 employees is to be built. Double work areas are planned, with 4 cables connected to each area. A data/telephone connection will be installed in the work area. The third and fourth outlet will be reserved for future applications and fitted with two blank inserts. It is assumed that a 1200 MHz cable (AWG22) and an average cable length of 60 m will be installed. Angled wall outlets are used, colour RAL The floor distributor will house a 24-port panel. This gives the following: 45

46 Position Product Order Number Quantity 1 PiMF cable, AWG 22, 1200 MHz m 2 Patch Panel, 24 Port items 3 Angled Wall Outlet items 4 2x Insert Data/Telephone, Cat items 6 Blank Insert items 7 1x Single Insert (for certification) items This configuration is very suitable for medium to large companies. Frequent moves create ever-changing situations yet this configuration allows an extra employee to be connected at any time. The two spare ports leave all future connectivity options open, such as Power over Ethernet or CATV applications. Installation With higher frequencies and more sensitive services the installation is one important part to provide a certain performance. AMP Netconnect provides a special tool to terminate the edge connector always with the same quality and makes installations as easy as possible. ACO tool The procedure is as follows. Cable preparation 1. As usual the cable has to be prepared. 2. The Shielded edge connector and the cable have to be placed in the mould 3. Activate the pistol grip. The conductors will be cut automatically. Remove the edge connector. 4. Finished. Part Number of the tool: Part number Instruction sheet Mould in tool Terminated wires 46

47 20 Testing Procedure The design of the ACO Plus system requires the following testing procedure to be followed. All links shall be certified with a single insert. The insert x shall be used for certifying a Class E link, x for Class F. Certification with AMP CO This procedure is absolutely essential in order to include all requisite parameters and to be compliant to ISO and EN For instance, it is not possible to measure POWERSUM values with a dual insert. Once the certification has been completed successfully the desired insert can be mounted on the wall outlet and the patch panel. It is necessary to follow the instructions of the testing instrument manufacturer. The following points shall be considered before start with testing: Condition of test cables and adapters Calibration of the test equipment Current status of the software Correct settings of the parameters Testing above 500 MHz Testing above this frequency is sensitive and care shall be taken into consideration. All new existing testers (August 2006) on the market are able to measure up to 1000 MHz, but they do it with a measurement uncertainty up to 5 db! This means in regards to interpretation of results that this range is around the shown value. In other words, even results closed to the limits may have enough headroom and opposite. This means that for certain parameters (e.g. R L ), this range in measurement uncertainty is nearly the same as the expected value at 500 MHz! For class F and F A the only allowed method is a channel test, hence the patchcords have a tremendous effect. Make sure that they are always in good conditions. ANEXT field testing As all shielded systems have a superior coupling attenuation, field testing of ANEXT is not necessary. It s fulfilled by the shielded design, while all UTP systems have to be tested. 47

48 21. Conclusion The AMP CO Plus System represents the highest performing and cost-effective system on the market today. The advantages at a glance: Most competitively priced All standards compliant link classes in a single system Matches every connector interface Matches different electrical environments All services via a single system e.g. 10/100/1000/10000 MBit/s Ethernet, telephone, CATV, V24, and many more Best available investment protection Absolute flexibility and adaptation to use this requirements Scalability of installed infrastructure AMP CO Plus provides a cost-effective opportunity to provide network infrastructures. The vast range of configurations and design options enables the individual needs of each user to be met. Now it is possible to install cables for future applications, without having to specify a specific connector. Unwanted investments and unused potential are avoided. In a world where trends and technologies come and go and the only certainty is that they will keep on changing, AMP CO Plus grows as your business grows. Who knows today what services, applications and connectors the future will bring? Nobody but your best level of protection is to use the AMP CO Plus system. Since the launch of the system in 1990 more than 10 million inserts have been sold. It is clear that a huge number of businesses have confidence in the performance together with the added flexibility the system provides. Why not join them? 48

49 22. Component Guide Please note: The products on the followings pages show only the main products. For all products, please refer to our EMEA catalogue. For the latest technical specifications, please check in case of uncertainty the customer drawing. Horizontal cable 1200 MHz PiMF Cable Product Facts: 1200 MHz high-performance S/FTP cable Enables broadband applications like CATV, Multimedia, e.g. Individually shielded pairs /aluminium foil) plus overall copper braid AWG 22 or 23 conductor Fire retardant LSZH sheath Color: white AWG Type OD Packaging Part Number. 22 Simplex 8,1 mm 1000 m/reel Simplex 7,9 mm 1000 m/reel Duplex 2 x 8,1, mm 500 m/reel Duplex 2 x 7,9 mm 500 m/reel Cat MHz PiMF Cable Product Facts: 600 MHz Cat. 7 S/FTP cable Individually shielded pairs (aluminium foil) plus overall copper braid AWG 23 solid conductor Fire retardant LSZH sheath Color: white AWG Type OD Packaging Part Number. 23 Simplex 7,3 mm 1000 m/reel Duplex 2 x 7,6 mm 500 m/reel

50 Kit Kit Kit AMP CO Plus 8 Port Panel Product Facts: 19" patch panel with 8 Ports (max.16 connections if dual inserts are applied) Performance up to 2,0 GHz Straight cable exit plus management bar includes 8 shielded housings, edge connectors, frames and mounting material inc. Grounding bolt Type Height Color Part Number Standard 1 U light grey (RAL7035) With label arrays 1,5 U Pure white (RAL 9010) Standard 1 U black (RAL 9005) AMP CO Plus 16 Port Panel Product Facts: 19" patch panel with 16 Ports (max.32 connections if dual inserts are applied) Performance up to 2,0 GHz Straight cable exit plus management bar includes 16 shielded housings, edge connectors, frames and mounting material inc. Grounding bolt Type Height Color Part Number Standard 2 U light grey (RAL7035) With label arrays and management bar 3 U black (RAL 9005) With label arrays and management bar 3 U Pure white (RAL 9010) Standard 2 U Pure white (RAL 9010) AMP CO Plus 24 Port Panel Product Facts: 19" patch panel with 24 Ports (max.48 connections if dual inserts are applied) Performance up to 2,0 GHz Straight cable exit plus management bar includes 24 shielded housings, edge connectors, frames and mounting material inc. Grounding bolt Type Height Color Part Number Standard 2 U Light grey (RAL 7035) Standard 2 U Black (RAL 9005)

51 Adapter Inserts AMP CO Plus ISO Category 7 Inserts Product Facts: Exchangeable system insert for 1 x ISO Cat. 7 (Siemon TERA) Cat 7 Class F up to 600 MHz Application: all applications incl. all Gigabit Ethernet versions Pin out: EIA/TIA 568 A; 8 pins shielded Type Part number Color -X Insert ISO Cat x almond (RAL 1013) black (RAL 9005) pure white (RAL 9010) AMP CO Plus Cat.7 Dual RJ-45 Insert, 2 Pairs Product-Facts: Exchangeable system insert 2x RJ-45 Category 7/Class F (Pair 12, 78 according E-DIN ) Application: 2x ATM 622 MBit/s or 1000 Base TX-2 PIN out: 12, ,78, 2x 4 pins, shielded Type Part Number Color -X Insert 2xRJ -45 Cat x almond (RAL 1013) black (RAL 9005) pure white (RAL 9010) AMP CO Plus Triple CATV + Data and Telephone Product Facts: Exchangeable system insert-f-series connector+ 2x RJ 45 Application:1 x CATV (862 MHz) or Video, 1 x Fast Ethernet and ISDN or Telephone, PoE ready PIN out: Balun 75Ω/100Ω; shielded 12, Type Part Number Color -X Triple 2x RJ 45 / CATV x almond (RAL 1013) black (RAL 9005) pure white (RAL 9010)

52 AMP CO Plus 3 Port Insert Product Facts: Exchangeable system insert 3x RJ45 2 x Telephone (2 wire), 1x Fast Ethernet Application: Ethernet, Telephone, DSL, PoE ready Pin out: , 36; 2 x 2 pins unshielded; 1 x 4 pins shielded Type Part number Color -X Triple insert X almond (RAL 1013) black (RAL 9005) pure white(ral 9010) AMP CO Plus Category 6 Universal Insert for all applications Product-Facts: Exchangeable system insert 1 x RJ-45 Cat. 6 Pyramid Tested/Class E up to 250 MHz Application: 1 x all applications incl. Gigabit Ethernet 1000 Base-T, TX or 1,2 GBit ATM, PoE ready Pin out: EIA/TIA 568 A: 8 pins, shielded Type Part Color -X Insert Cat. 6 Insert for Class E A (10G) X X almond (RAL 1013) black (RAL 9005) pure white (RAL 9010) AMP CO Plus Category 6 Dual Insert Fast Ethernet Product Facts: Exchangeable system insert 1 x RJ-45 Cat. 6 Pyramid Tested/Class E up to 250 MHz Application: 2 x Fast Ethernet 100 Base-TX, PoE ready Pin out:12, ,36; 2 x 4pins; shielded Type Part Number Color -X Dual Insert 2x Fast Ethernet x almond (RAL 1013) black (RAL 9005) pure white (RAL 9010)

53 AMP CO Plus Category 6 Dual Insert ISDN/DSL Product Facts: Exchangeable system insert 2 x RJ-45 Cat. 6 Pyramid Tested/Class E up to 250 MHz Application: 2 x ISDN, xdsl or Token Ring Pin out: 36, ,45; 2 x 4pins; shielded Type Part Number Color -X Insert 2x RJ 45 Cat. 6 ISDN or Telephone x almond (RAL 1013) black (RAL 9005) pure white (RAL 9010) AMP CO Plus Dual Patch Panel Insert PoE Power Convers. Product Facts: Exchangeable system insert 2 x RJ-45 2 x Power over Ethernet Converts IEEE 802.3af mode B input to mode A output Uses Power Mux/Demux Technology A pplication: 2 x PoE ( When Input is Mode B IEE 802.3af on 36, 45), e.g. VoIP, over a 4 pair cable (sheath sharing) Pin out:12, ,36; 2 x 4pins; shielded Type Part Number Color -X Insert 2 x PoE Power Conversion X almond (RAL 1013) black (RAL 9005) pure white (RAL 9010) AMP CO Plus Dual Patch Panel Insert ISDN/PoE Power Convers. Product Facts: Exchangeable system insert 2 x RJ-45 2 x Power over Ethernet PoE Port: Converts IEEE 802.3af mode B input to mode A output ISDN Port: analogue telephone or ISDN Uses Power Mux/Demux Technology Application: 2 x PoE ( When Input is Mode B IEE 802.3af on 36, 45), e.g. VoIP, over a 4 pair cable (sheath sharing) Pin out: 12, ,45; 2 x 4 pins; shielded Type Part Number Color -X Insert 1 x PoE Power Conversion+ 1 x ISDN X almond (RAL 1013) black (RAL 9005) pure white (RAL 9010)

54 AMP CO Plus 4x Telephone Insert Product-Facts: Exchangeable system insert 4 x RJ-45 Application: 4 x Telephone Pin out: 4 x 4,5 Insert Part Number Color -X 4x Telephone insert 4x Telephone Insert (ISDN S0 Bus) X X1 almond (RAL 1013) black (RAL 9005) pure white (RAL 9010) Wall outlets and underfloor Kit s AMP CO Plus Installation Kit 50 x 50 mm Product Facts: Shielded installation kit flushmount DIN faceplate 50 x 50 mm, Metal frame Compatible with standard and designer frame series Shielded edge connector Mark II with PiMF management Shielded housing with 360 cable clamp and Strain relief Top, left or right cable entry 2,0 GHz Performance Color Part Number Almond (RAL 1013) Pure white (RAL 9010) black (RAL 9005) AMP CO Plus Installation Kit Underfloor Product Facts: Shielded installation kit Bottom cable exit For underfloor installation boxes Shielded edge connector MARK II with PiMF management Shielded housing with 360 cable clamp Strain relief 2,0 GHz Performance For NOVAR Ackermann 60 mm systems Color Faceplate Part Number almond (RAL 1013) 70 x 58 mm For Elektraplan (KD E 2, E 4 und Q4) Color Faceplate Part Number almond (RAL 1013) 50 x 50 mm

55 AMP CO Plus Installations Kit Angled Product Facts: Shielded installation kit angled DIN faceplate 68 x 68 mm with 6 x 32 label Metal frame Shielded edge connector Mark II with PiMF management Shielded housing with 360 cable clamp Strain relief, Rear cable entry 2,0 GHz Performance Color Part Number almond (RAL 1013) Pure white (RAL 9010) AMP CO Plus Installations Kit CH EDIZIOdue Product Facts: Shielded installation kit flushmount Applicable to "EDIZIOdue" systems Left, right or top cable exit Faceplate EDIZIOdue Shielded edge connector Mark II with PiMF Management Shielded housing with 360 cable clamp Strain relief 2,0 GHz Performance Description Color Part Number Edizio Kit Standard Pure white AMP CO Plus Installation Kit 45 x 45 mm Mosaic Product Facts: Shielded installation kit flushmount Applicable to 45 x 45 mm Mosaic systems Faceplate 45 x 45 mm Shielded edge connector MARK II with PiMF management Shielded housing with 360 cable clamp Strain relief Left or right cable exit 2,0 GHz Performance Description Color Part Number 45 x 45 mm Inst. Kit Almond (RAL 1013) x 45 mm Inst. Kit Pure white (RAL 9010) Description Color Part Number Adapter Frame Almond (RAL 1013)

56 AMP CO Plus Installation Kit for Australia and NZ Clipsal Faceplate Product Facts: Clipsal 2000 Face Plate and ACO Dual installation kit. Applicable to Clipsal faceplates Shielded edge connector MARK II with PiMF management Description Color Part Number Single Installation Kit Dual Kit Mounting centres 83.5mm Pure white IP 44 outlet for harsh environments Product Facts: Lockable, spray-water proof dual Outlet for industrial and semi-industrial Environments. Housing complies to IP 44Definitions and is pre-loaded with an AMP CO Plus shielded Housing Accepting 1 or 2 port Inserts Robust and ball-safe wallmount housing (acc. DIN 18032) Color Part Number RAL 7035 (light grey) PimF patch cords Product Facts: 4-pair stranded S/FTP cable 600 MHz S/FTP cable construction LSZH sheath Colour-matched snagless boots Universal wiring Color White Blue Grey Yellow Red Green Part Number Y X Y X Y X Y X Y X Y X Y- -X Length ,0 m ,0 m ,0 m ,0 m m 56

57 Category 7 Insert 1T 1R 2T 2R 3T 3R 4T 4R = Blue/white 2= Blue 3= Orange/white 4= Orange 5= Green/white 6= Green 7= Brown/white 8= Brown Note: All inserts, technical drawings and specifications can be found in the EMEA catalogue Shield Edge Connector PN x Category 6 Insert Shield PN x Edge Connector 1= Blue/white 2= Blue 3= Orange/white 4= Orange 5= Green/white 6= Green 7= Brown/white 8= Brown Shield = Blue/white 2= Blue 3= Orange/white 4= Orange 5= Green/white 6= Green 7= Brown/white 8= Brown Shield Edge Connector PN x Shield = Blue/white 2= Blue 3= Orange/white 4= Orange 5= Green/white 6= Green 7= Brown/white 8= Brown Shield = Blue/white 2= Blue 3= Orange/white 4= Orange 5= Green/white 6= Green 7= Brown/white 8= Brown Shield Edge Connector Shield Edge Connector PN x PN x 57

58 Category 6 Triple Insert Shield Shield = Blue/white 2= Blue 3= Orange/white 4= Orange 5= Green/white 6= Green 7= Brown/white 8= Brown Shield Edge Connector PN x Power over Ethernet Insert Shield Power Converter Power Converter Edge Connector 1= Blue/white 2= Blue 3= Orange/white 4= Orange 5= Green/white 6= Green 7= Brown/white 8= Brown Shield = Blue/white 2= Blue 3= Orange/white 4= Orange 5= Green/white 6= Green 7= Brown/white 8= Brown Shield PN x Power Converter 8 8 Edge Connector Shield PN x 58

59 Index 10 Gigabit...10 IEEE 802.3af Gigabit Ethernet...7 installation environment x insert34 ISDN... 33, 35 Alien Crosstalk...6 Mark II Analogue...33 Midspan PSE Mode B... 22, 24 Background Noise...6 Outlet Switch Coupling attenuation...7 PiMF Management EMC compliance...6 Planning with AMP CO EN Power Multiplexing Endpoint PSE Mode A...22 Power over Ethernet Endpoint PSE Mode B...22, 23 Testing fire load...43 TV applications fire proof...43 System warranty We make sure that your AMP NETCONNECT system will keep performing to current industry standards. If ever it does not meet those standards within 25 years of the date of installation, we ll provide the reasonable parts and labour to replace or repair the AMP NETCONNECT product. 25 years coverage on system performance 25 years coverage on components 25 years coverage on applications Based on industry standards Includes parts and labour Tyco Electronics provides coverage directly to the end userif something is wrong Tyco Electronics will make it right 59

What really changes with Category 6

What really changes with Category 6 1 What really changes with Category 6 Category 6, the standard recently completed by TIA/EIA, represents an important accomplishment for the telecommunications industry. Find out which are the actual differences

More information

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions Robert Burén Product Manager 10G Solutions Nexans Cabling Solutions 1 10 Gigabit Ethernet.Performance 30 GByte can be transmitted within 24 seconds Example: MRI-scan size is 30GB as average A memory device

More information

technicalreport MegaLine Connect100 Class E A links over 100 metres in length Data communication technology 09/2018 Classic structure 2-connector link

technicalreport MegaLine Connect100 Class E A links over 100 metres in length Data communication technology 09/2018 Classic structure 2-connector link technicalreport Data communication technology 09/2018 Classic structure 2-connector link Ethernet transmission with twisted pair cables Limiting factors for links > 100 m Example structure of a 2-connector

More information

FlexCabling. Hemmaprodukter. Tillbehör. Kontorsprodukter. Övrigt

FlexCabling. Hemmaprodukter. Tillbehör. Kontorsprodukter. Övrigt FlexCabling Hemmaprodukter Skåp 4U Skåp 6U Skåp 9U x 12 (Cat 5E) Management Panel TV/Radio Splitter 1 4 TV/Radio Splitter 1 8 TV- och radiokabel Telefonsplitter Ethernets-switch (Gigabit) Tillbehör AV

More information

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS 10 Gigabit Ethernet is nowadays viable solution for destinations with very high data traffic concentration like data center, server farms, MAN s and backbones. Premium Line Category 6A Cabling Solutions

More information

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS 10 Gigabit Ethernet is nowadays viable solution for destinations with very high data traffic concentration like data center, server farms, MAN s and backbones. Need of 10 Gigabit Service Application as

More information

Belden IBDN System 10GX Enabling Technologies

Belden IBDN System 10GX Enabling Technologies Belden IBDN System 10GX Enabling Technologies by Paul Kish Director, Systems and Standards Revision 1 November 2008 Belden Belden IBDN System 10GX Enabling Technologies 1/17 Introduction The IEEE 802.3an

More information

CATEGORY 5e CABLING SOLUTIONS

CATEGORY 5e CABLING SOLUTIONS With the high speed data transmission requirement in LAN, 1998 IEEE ratified standard 802.3z defined protocol 1000BASE-T over Category 5e and higher level Ethernet cabling system. After that, with the

More information

Bravo AV s Structured or Whole-House Wiring Approach

Bravo AV s Structured or Whole-House Wiring Approach Custom Audio & Video Systems: Design and Installation Bravo AV s Structured or Whole-House Wiring Approach THE QUALITY OF THE CABLE YOU USE IS CRITICALLY IMPORT TO THE PERFORMANCE OF YOUR SYSTEM Introduction

More information

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System

10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System 10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System Next-Generation Category 6A UTP Cabling System Drivers for 10 GbE Aggregation of Gigabit Links Server Consolidation and

More information

Volition TM RJ45 K5e Jacks

Volition TM RJ45 K5e Jacks Volition TM RJ45 K5e Jacks Part of our 3M Volition Network Solutions, the new K5e range is our ultimate Category 5e hardware component (ISO/IEC 11801, EN 50173 and ANSI/TIA/EIA-568). The K5e jack is a

More information

White Paper. Fibre Optic Technologies for Satellite Communication and Broadcast Industries. By Tom Lacey Applications Engineering Group PPM Ltd, UK

White Paper. Fibre Optic Technologies for Satellite Communication and Broadcast Industries. By Tom Lacey Applications Engineering Group PPM Ltd, UK White Paper Fibre Optic Technologies for Satellite Communication and Broadcast Industries By Tom Lacey Applications Engineering Group PPM Ltd, UK Abstract The satellite communications and broadcast industries

More information

384A Adapter Installation Instructions

384A Adapter Installation Instructions Instruction Sheet 860237684 Issue 9, October 2012 SYSTIMAX Solutions 384A Adapter Installation Instructions General The 384A adapter (Figure 1) is a broadband video adapter that provides connectivity to

More information

Belden IBDN System 10GX The next level of cabling performance

Belden IBDN System 10GX The next level of cabling performance Belden IBDN System 10GX The next level of cabling performance by Paul Kish Director Belden IBDN Systems and Standards Introduction There is a new standard under development in the IEEE 2.3an task force

More information

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION 14 LCS 2 Copper A complete system for higher performance Connectors See pages 16 to 19 LCS 2 copper Patch panels See pages 21 to

More information

Compact Module. Category 6 FTP Cabling System

Compact Module. Category 6 FTP Cabling System Compact Module Shielded design for improved EMI performance Suitable for Gigabit Ethernet applications and beyond Ultra-slimline design Colour coded for quick and accurate termination Interchangeable with

More information

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE) PART 1: GENERAL 1.01 Telecommunications Engineer Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE) B. Registered Communications Distribution Designer

More information

Design criterias for high speed networks Thorsten Punke Dipl. Ing. Marketing Manager EMEA

Design criterias for high speed networks Thorsten Punke Dipl. Ing. Marketing Manager EMEA Design criterias for high speed networks Thorsten Punke Dipl. Ing. Marketing Manager EMEA A publication of Tyco Electronics Introduction If someone, some years ago were to say that copper systems will

More information

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017 Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM-2017-2 Date: 05/26/2017 Additional specification information for data communication to cameras and between Library

More information

Follow The Leader In Shielded Technology

Follow The Leader In Shielded Technology 1970s Vampire Tap 1990s Shielded Modular Jack 190s 4 Position Data Connector Follow The Leader In Shielded Technology The new AMP-TWIST Jack is our latest shielded product evolution. It can be terminated

More information

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page

More information

High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring. John L. Hill AMP Incorporated July, 1998

High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring. John L. Hill AMP Incorporated July, 1998 High Speed Data Connector (HSSDC) For 100 MBit/Sec Token Ring John L. Hill AMP Incorporated July, 1998 High Performance Cable Assembly Characteristics Controlled/Matched Impedance Connectors and Cables

More information

HELLERMANNTYTON DESCRIPTION DIMENSIONS PKG. PART NO. (HXWXD) QTY. RE18 Residential Enclosure Base: 18 H x 14.1 W x 4 D 1 Cover: 19.5 H x 15.

HELLERMANNTYTON DESCRIPTION DIMENSIONS PKG. PART NO. (HXWXD) QTY. RE18 Residential Enclosure Base: 18 H x 14.1 W x 4 D 1 Cover: 19.5 H x 15. HOME NETWORK SCIENCES FROM HELLERMANNTYTON The Home Network Sciences system allows for: Telephone Distribution Video and TV Distribution Whole-House Audio Computer Networking using DSL and Cable Modems

More information

How to Implement PoE in Your Harsh Industrial Environment

How to Implement PoE in Your Harsh Industrial Environment Produced by: Engineering 360 Media Solutions July 2018 How to Implement PoE in Your Harsh Industrial Environment Sponsored by: Quabbin Wire & Cable Co., Inc. There is little doubt that the internet of

More information

LYNX ULTRA Series Hubs and Baluns

LYNX ULTRA Series Hubs and Baluns Introducing The New LYNX ULTRA Series Hubs and Baluns 4K and HDTV on Cat 6 Cable Product Highlights 800 Digital RF Channels Distributed on Cat 5 or Cat 6 Cable 860 MHz over 100 Meters 4K, 8K, HD or SD

More information

Multi-Media Installation Guide

Multi-Media Installation Guide Multi-Media Installation Guide Coaxial Page 2 Data Plug Page 7 Data Jack Page 10 Telephone Page 13 Splicing Page 15 Cable Types Cable Types Two basic types of cable are used in multimedia installations.

More information

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab* Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab* General Scope of Work: Supply and installation of Computer Laboratory setup in MIU Location of Installation:

More information

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION COMMUNICATIONS HORIZONTAL CABLING (NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) PART 1 - GENERAL 1.1 SECTION

More information

STRUCTURED CABLING SYSTEMS (SCS)

STRUCTURED CABLING SYSTEMS (SCS) STRUCTURED CABLING SYSTEMS (SCS) ModSecur - Structured Cabling Systems (SCS) A Structured Cabling System (SCS) is the backbone of any building, campus or site communication infrastructure. The sharp growth

More information

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH USER GUIDE AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH Electromagnetic Compatibility (EMC) This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in

More information

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports RJ45 - Cat. 6A Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports Compatible with FO trunks Modern data centre trunk solution in modular cassette technology Pre-terminated

More information

Category 6A UTP cables shall be tested and proved to conform to TIA-568-C.2 standards.

Category 6A UTP cables shall be tested and proved to conform to TIA-568-C.2 standards. 27 08 00 Certification and Commissioning of Communication Systems (Revision date: 7/3/12) 1.0 Purpose A. These guidelines provide requirements for designers to incorporate into bid documents. They are

More information

CATEGORY 6 CABLING SOLUTIONS

CATEGORY 6 CABLING SOLUTIONS With over 20 years experience and know-how on communicating products design & developing, Premium Line has built maturity systems both in high tech develop and research center & complete structural quality

More information

Information & Communications Technology Network Infrastructure Group. Network Infrastructure Standards June 2008

Information & Communications Technology Network Infrastructure Group. Network Infrastructure Standards June 2008 Information & Communications Technology Group Standards June 2008 Appendix F UTP cabling Version 1.1 Appendix F UTP cabling 1. Introduction This Section details the required standards for Unshielded Twisted

More information

Everything you always wanted to know about HDBaseT*

Everything you always wanted to know about HDBaseT* Everything you always wanted to know about HDBaseT* * But were afraid to ask Bill Lauby Sr. Product Manager Leviton Network Solutions Speaker Bio Bill Lauby, Sr. Product Manager Leviton Network Solutions

More information

Magic Patch Patch Leads & Accessories

Magic Patch Patch Leads & Accessories Magic Patch Patch Leads & Accessories T: 01376 346600 F: 01376 346620 www.connectixcablingsystems.com Issue 1.1 Magic Patch Cabling Systems TM Magic Patch Connectix Cabling Sytems TM range of patch leads,

More information

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE Prepared in cooperation and approval from BICSI Building Industry Consulting Services International and

More information

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel 1993 Specifications CSJ 0924-06-223 SPECIAL SPECIFICATION 1160 8:1 Video (De) Mux with Data Channel 1. Description. This Item shall govern for furnishing and installing an 8 channel digital multiplexed

More information

THE FUTURE OF NARROWCAST INSERTION. White Paper

THE FUTURE OF NARROWCAST INSERTION. White Paper THE FUTURE OF NARROWCAST INSERTION White Paper May/2013 The future of narrowcast insertion Next generation, CCAP compliant RF combining This paper looks at the advantages of using the converged cable access

More information

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue. Description: OZLINX CAT5e cable has a guaranteed performance; exceeds the Category 5e performance requirements and provides positive PSACR up to 155MHz for bandwidth requirement in the future. Product

More information

HDMI / Video Wall over IP Receiver with PoE

HDMI / Video Wall over IP Receiver with PoE / Wall over IP Receiver with Key Features Network 1080P ultra high quality video transmitter Assigns video sources to any monitor of the video wall Up to 8 x 8 Screen Array supported Extends high definition

More information

10 Mb/s Single Twisted Pair Ethernet Preliminary Cable Properties Steffen Graber Pepperl+Fuchs

10 Mb/s Single Twisted Pair Ethernet Preliminary Cable Properties Steffen Graber Pepperl+Fuchs 10 Mb/s Single Twisted Pair Ethernet Preliminary Cable Properties Steffen Graber Pepperl+Fuchs IEEE802.3 10 Mb/s Single Twisted Pair Ethernet Study Group 9/8/2016 1 Overview Cable Properties Cable Measurements

More information

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION PART 1 - GENERAL 1.1 SUMMARY SCOPE SECTION 25170 TESTING, IDENTIFICATION AND ADMINISTRATION 1. This section includes the minimum requirements for the testing, certification administration and identification

More information

LCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS

LCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS LCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS Global strength built on local knowledge Legrand is the global specialist in electrical

More information

distribution passives basic series

distribution passives basic series distribution passives basic series SAL001_US_01 about dktcomega DKTCOMEGA develops optical and coaxial products for professional broadband operators and solution providers. The company was founded in 1977.

More information

Advanced PoE - The Impact of Higher Power PoE++ on Twisted-Pair Structured Cabling

Advanced PoE - The Impact of Higher Power PoE++ on Twisted-Pair Structured Cabling Advanced PoE - The Impact of Higher Power PoE++ on Twisted-Pair Structured Cabling Next Generation PoE Connect significantly more devices due to higher power Affects cabling due to the additional heat

More information

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch HDMI Extender over Single CAT 6 Cable with IR Control Model 103002 Extend HDMI audio and video connections up to 300 feet Utilize existing Cat 6 wiring for an easy installation Add up to 8 additional receivers

More information

All-digital planning and digital switch-over

All-digital planning and digital switch-over All-digital planning and digital switch-over Chris Nokes, Nigel Laflin, Dave Darlington 10th September 2000 1 This presentation gives the results of some of the work that is being done by BBC R&D to investigate

More information

FUTURE PROOF YOUR CONNECTIONS

FUTURE PROOF YOUR CONNECTIONS FUTURE PROOF YOUR CONNECTIONS DataMax Commercial Data Cable The Strongest Link. When you choose Quabbin Wire and Cable you are not only selecting a premier cable, you are also investing in productivity

More information

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box. FTTH & FITH Discreet optical fiber solutions from the network connection point to the set-top box www.omelcom.com FIBER: THE FUTURE IS HERE The past several years have seen major progress in the penetration

More information

CAT6Plus System. Brand-Rex Limited

CAT6Plus System. Brand-Rex Limited Brand Rex introduces it's New CAT6Plus Cabling Solution, designed to deliver an optimum performance cabling system. All products in the CAT6Plus system have 3rd party approval* and therefore either meet

More information

LCS2 Cat. 6 RJ 45 Patch panels and units

LCS2 Cat. 6 RJ 45 Patch panels and units 87045 LIMOGES Cedex Telephone: 33 0 5 55 06 87 87 - Fax: 33 0 5 55 06 88 88 LCS2 Cat. 6 RJ 45 CONTENTS Page 1. General characteristics....1 2. Presentation...2 3. Installation...2 4. Technical characteristics...2

More information

LANmark. Copper Cabling Solutions

LANmark. Copper Cabling Solutions LANmark Copper Cabling Solutions Edition 01/03/2001 Copyright Nexans 2001 Subject to change without prior notice. In this publication, no mention is made of rights with respect to trademarks or tradenames

More information

Selecting Cables for Power over Ethernet

Selecting Cables for Power over Ethernet Hitachi Cable America Inc. Selecting Cables for Power over Ethernet Factors to Consider when Selecting the Appropriate Cable 8/12/217 Ratio of Power Dissipated vs 1 Power over Ethernet Standards and applications

More information

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1 Modular Solutions Subject to technical changes! 1 Since 1986, braun telecom has stood for continuity and competence in broadband communication and has become one of the leading suppliers of products and

More information

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

Product information 19 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated R512417 966740615 1 Pcs. 090.6102 Metal patch panel with integrated cable tie shelf. 19" 1U HD patch panel 4 12-port/s

More information

HighBand 25. TrueNet Category 6 Solutions

HighBand 25. TrueNet Category 6 Solutions HighBand 25 TrueNet Category 6 Solutions The highest performing cross-connect system in the world. A unique high-density solution with superior cable management. ADC KRONE s HighBand 25 cross connect solution

More information

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER

OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER OPERATOR MANUAL OSD8865 DIGITAL TRIPLE VIDEO FIBER OPTIC RECEIVER INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND BENEFITS...

More information

Clarity Advanced Solutions6A

Clarity Advanced Solutions6A Clarity Advanced Solutions6A Clarity 6A connectivity more effectively supports the internal and alien performance requirements of 10 Gigabit Ethernet. Clarity 6A components use Ortronics innovative technique

More information

Truck router (3Gbps/HD/SD/ASI)

Truck router (3Gbps/HD/SD/ASI) NVISION 8288 Truck router (3Gbps/HD/SD/ASI) The ultra-compact NVISION 8288 truck video routers are the world s smallest large routers with full broadcast quality, resilience and advanced control systems.

More information

CAT5 VGA Extender. Mode 1 Mode 2

CAT5 VGA Extender. Mode 1 Mode 2 ITEM NO.: TTP111VGA CAT5 VGA Extender The VGA Extender allows VGA video signals to be transmitted up to 135 meters via 4-paris CAT5 STP or UTP cable. Used in pairs, the VGA Extender is used in home or

More information

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X

Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X HMS-X_bro_de-en_3607-0181-3X_v0200.indd 1 Product Brochure 02.00 Test & Measurement Spectrum Analyzer 1.6 GHz 3 GHz R&S HMS-X 15.03.2016 15:24:06 1 Basic Unit + 3 Options Key facts Frequency range: 100

More information

2015 OPTICAL TRANSMITTERS

2015 OPTICAL TRANSMITTERS 2015 OPTICAL TRANSMITTERS Released V H Mar 15 SATELLITE AND TERRESTRIAL OPTICAL BROADCAST EQUIPMENT DVB is a registered trademark of the DVB Project A DVA NCE D TECHNOLOGY FOR PROFESSIONAL BROADCASTING

More information

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published White Paper How to Specify MTP Pre-terminated Optical Cabling Published January 2009 The benefits of pre-terminated cabling The two principal advantages of pre- terminated cabling are reduced time on site

More information

Series 3000 Dual Cast Transmitter

Series 3000 Dual Cast Transmitter Hans H. Plisch GmbH + Co. KG Edition: 02/2009 Series 3000 Dual Cast Transmitter Hans H. Plisch GmbH + Co. KG TDV 3000 Dual Cast Liquid Cooled UHF Transmitter Dual Cast Liquid Cooled UHF Transmitter TDV

More information

IFS MC252-1T-1CXP and MC252-1P-1CX User Manual

IFS MC252-1T-1CXP and MC252-1P-1CX User Manual IFS MC252-1T-1CXP and MC252-1P-1CX User Manual P/N 1072682 REV A ISS 22OCT13 Copyright Trademarks and patents Manufacturer Intended use 2013 United Technologies Corporation Interlogix is part of UTC Climate

More information

LAN Cabling Systems Copper

LAN Cabling Systems Copper LAN Cabling Systems Copper Table of content About Nexans 3 Copper 4 Essential Cat 5e Cable 5 LANmark-6 Cable 7 LANmark-6A Cable 9 LANmark-7 Cable 11 LANmark-7A Cable 13 Legal Notice 14 8/20/11 - http://www.nexans-fi.com

More information

HDO701 FIBRE OPTIC TRANSMITTER

HDO701 FIBRE OPTIC TRANSMITTER Timo Rantanen 12.7.2011 1(5) HDO701 FIBRE OPTIC TRANSMITTER HDO701 is a high performance, extremely linear externally modulated 1550 nm transmitter for fibre optic CATV links. This transmitter type has

More information

PROMAX NEWSLETTER Nº 25. Ready to unveil it?

PROMAX NEWSLETTER Nº 25. Ready to unveil it? PROMAX NEWSLETTER Nº 25 Ready to unveil it? HD RANGER Evolution? No. Revolution! PROMAX-37: DOCSIS / EuroDOCSIS 3.0 Analyser DVB-C2 now available for TV EXPLORER HD+ C-band spectrum analyser option for

More information

PREMIUM 5e F/UTP PRODUCTS

PREMIUM 5e F/UTP PRODUCTS Siemon s end-to-end cabling system is guaranteed to provide transmission performance margins in excess of industry standards for category 5e parameters, while featuring excellent EMI resistance. has been

More information

SAT IF distribution system

SAT IF distribution system 7. Technical specifications Type cs43 RF input frequency range pr. 50-350 MHz inputs number 4 level pr. 55...88 dbµv 60...93 dbµv symbol rate 3 45 Ms/s return loss/impedance > 0 db/75 Ω LNB powering/control

More information

TV4U QUAD DVB-S2 to DVB-C TRANSMODULATOR

TV4U QUAD DVB-S2 to DVB-C TRANSMODULATOR INSTRUCTION MANUAL Features of the new DVB-C transmodulators line Through the use of the FPGA technology the transmodulators provides the highest performance at the lowest price. Four carriers are formed

More information

The first TV Smart Headend designed for Hospitality SOLUTIONS FOR IN-ROOM ENTERTAINMENT PROVIDERS AND INTEGRATORS

The first TV Smart Headend designed for Hospitality SOLUTIONS FOR IN-ROOM ENTERTAINMENT PROVIDERS AND INTEGRATORS The first TV Smart Headend designed for Hospitality SOLUTIONS FOR IN-ROOM ENTERTAINMENT PROVIDERS AND INTEGRATORS 1 FLOW IN...3 FLOW SEC...4 FLOW ENC...5 FLOW OUT...6 FLOW HUB...7 FLOW BASE...8 FLOW PSU...9

More information

AS/NZS 1367:2016. Australian/New Zealand Standard

AS/NZS 1367:2016. Australian/New Zealand Standard AS/NZS 1367:2016 Australian/New Zealand Standard Coaxial cable and optical fibre systems for the RF distribution of digital television, radio and in-house analog television signals in single and multiple

More information

NanoStation NanoStation. NanoStation. Compact, Hi-Power, 2x2 MIMO AirMax TDMA Station. *Respaldo y Garantía. Datasheet

NanoStation NanoStation. NanoStation. Compact, Hi-Power, 2x2 MIMO AirMax TDMA Station. *Respaldo y Garantía. Datasheet Compact, Hi-Power, 2x2 MIMO AirMax TDMA Station Models: NSM2, NSM3, NSM365, NSM5, LOCOM2, LOCOM5, LOCOM9 Cost Effective, Hi-Performance Compact and Versatile Design Powerful integrated Antenna *Respaldo

More information

PoE: Adding Power to (IoT)

PoE: Adding Power to (IoT) Sponsored by: PoE: Adding Power to (IoT) Sponsored by: December 20th, 2018 1 Today s Speakers Sponsored by: Steve Bell Senior Analyst - IoT Heavy Reading Mohammad Shahid Khan Chief Manager (PLM & AE),

More information

User Manual. HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D

User Manual. HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D User Manual HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D Model 1180T Transmitter Model 1180R Receiver Model 1180TD Transmitter Model 1180RD Receiver WARNINGS Read these

More information

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to:

If you want to get an official version of this User Network Interface Specification, please order it by sending your request to: This specification describes the situation of the Proximus network and services. It will be subject to modifications for corrections or when the network or the services will be modified. The reader is

More information

DVX. Digital Versatile Headend

DVX. Digital Versatile Headend DVX Digital Versatile Headend TELESTE ACCESS SYSTEMS HEADEND PRODUCTS DVX Digital Versatile Headend - The Platform for Digital Age Overview Cable operators today are heavily affected by globalisation,

More information

Index Contents: 1000 Series Single Channel Multi Mode Fiber Optic Video Solutions Product Overview Product Configurations Product Specifications

Index Contents: 1000 Series Single Channel Multi Mode Fiber Optic Video Solutions Product Overview Product Configurations Product Specifications Welcome Nitek is a Rolling Meadows, Illinois based manufacturing company with a primary focus on design, development and manufacturing of high performance, reliable CCTV video transmission systems. Nitek

More information

HARTING Ethernet cabling cables and connectors, 4 wire

HARTING Ethernet cabling cables and connectors, 4 wire Industrial Cat. 5e Standard cable, 4-wire Type A for permanent installation or to build-up PROFINET system cables PVC X 8 wire X Cat. 5e X Cat. 6 Cat. 6 A Cat. 7 Cable structure Core structure Wire insulation

More information

SECTION 7 -- CROSS-CONNECT SYSTEMS

SECTION 7 -- CROSS-CONNECT SYSTEMS DETAIL ENGINEERING REQUIREMENTS AT&T March, 2016 Section 7, ATT-TP-76400 Revised NA SECTION 7 -- CROSS-CONNECT SYSTEMS CONTENTS PAGE 1. GENERAL... 7-2 1.1. Introduction... 7-2 1.2. Cable Holes... 7-2 1.3.

More information

SMPTE STANDARD Gb/s Signal/Data Serial Interface. Proposed SMPTE Standard for Television SMPTE 424M Date: < > TP Rev 0

SMPTE STANDARD Gb/s Signal/Data Serial Interface. Proposed SMPTE Standard for Television SMPTE 424M Date: < > TP Rev 0 Proposed SMPTE Standard for Television Date: TP Rev 0 SMPTE 424M-2005 SMPTE Technology Committee N 26 on File Management and Networking Technology SMPTE STANDARD- --- 3 Gb/s Signal/Data Serial

More information

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX Description This Ethernet Switch Module has been designed with 4x10/100Base-TX ports and 1x100Base-FX fiber optic port for the interconnection

More information

INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1

INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1 INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1 WWW.INFRASTONE.COM Contents BLACKSTONE CAT6A U/UTP channel performance Introduction BLACKSTONE CAT6A U/UTP channel

More information

Connect with the industry s best CAT6 and CAT5e channel solutions!

Connect with the industry s best CAT6 and CAT5e channel solutions! Connect with the industry s best CAT6 and CAT5e channel solutions! Our CAT6 and CAT5e channel solutions far exceed the TIA/EIA specifications performance standards! To ensure consistent and continuing

More information

SMART CLASSix 24/48 UTP Patch Panels -

SMART CLASSix 24/48 UTP Patch Panels - Features Support 24 ports per 1U, 48 ports per 2U. Conform to ANSI/TIA/EIA-568-B.2-1, ISO/IEC 11801 2 nd edition (2002) and CENELEC EN50173 (2002) for Category 6/Class E. Simple labor-saving termination

More information

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

SMART CLASSix 48 UTP Patch Panels (with patching switches) - Features Front-mounted Patching Switches connect ports internally, dramatically reducing the need for patch cords Compatible to Unshielded Twisted Pairs (UTP) cabling systems High performance panel that

More information

E3/DS3 Fibre Extender

E3/DS3 Fibre Extender User Manual E3/DS3 Fibre Extender Black Box Network Services 464 Basingstoke Road, Reading, Berkshire, RG2 0BG Tech: 0118 965 6000 www.blackbox.co.uk CONTENTS 1 Introduction 1 1.1 About the products 1

More information

European Product Catalog2009 AMP NETCONNECT Building Networks

European Product Catalog2009 AMP NETCONNECT Building Networks European Product Catalog2009 AMP NETCONNECT Building Networks AMP NETCONNECT Structured Cabling Solutions for Enterprise Networks The Foundation of Your Company s Network Table of Contents 1 Unshielded

More information

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights In-Building Wireless Networking System InterReach Fusion is the latest addition to ADC s portfolio of Distributed Antenna Systems. It offers the same superior performance as Unison in an easy-to-install,

More information

Your #1 Choice for CCTV and Audio-Video Connectivity Solutions. Broadcast Solutions.

Your #1 Choice for CCTV and Audio-Video Connectivity Solutions. Broadcast Solutions. Your #1 Choice for CCTV and Audio-Video Connectivity Solutions Broadcast Solutions Click below to link to a product category* *Note: Links on this page may only work in Slide Show view HD-SDI & 3G-SDI

More information

Next Generation PoE Standards and Codes Update. Frank Straka Panduit Corporation

Next Generation PoE Standards and Codes Update. Frank Straka Panduit Corporation Next Generation PoE Standards and Codes Update Frank Straka Panduit Corporation Introduction Power over Ethernet is a HOT topic! New power levels dramatically increasing PoE device types New standards

More information

Product Line Reference Guide

Product Line Reference Guide Product Line Reference Guide COPPER CABLING SYSTEMS AFL Copper Products COPPER CABLING SYSTEMS Copper Cabling Systems AFL s copper cabling systems are the best-in-class, providing superior performance

More information

MODEL NUMBER SRP-X700P

MODEL NUMBER SRP-X700P BID SPECIFICATION FOR POWERED MIXER / SWITCHER MODEL NUMBER SRP-X700P INSTRUCTIONS: REMOVE THIS COVER PAGE AND ADD TO REQUESTS FOR QUOTATION AND PROPOSALS. THE OBJECTIVE OF THIS BID SPECIFICATION IS TO

More information

JD725A Cable and Antenna Analyzer - Dual Port

JD725A Cable and Antenna Analyzer - Dual Port COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS JD725A Cable and Antenna Analyzer - Dual Port Key Features Portable and lightweight handheld instrument Built-in wireless frequency bands as well as the most

More information

Copper Solution Contents Cabinets Fiber Optic Solution

Copper Solution Contents Cabinets Fiber Optic Solution Contents Copper Solution Category 6A + Cabling Solutions Cat.6A + 1000MHz S/FTP Installation Cable A1 Cat.6A + S/FTP Patch Cord A2 Cat.6A + 90 Fully Shielded Die-casting Keystone Jack A3 Modular German

More information

Versatile EMS and EMI measurements for the automobile sector

Versatile EMS and EMI measurements for the automobile sector EMC/FIELD STRENGTH EMC Measurement Software R&S EMC32-A Versatile EMS and EMI measurements for the automobile sector EMC Measurement Software R&S EMC32-A (automotive) from Rohde & Schwarz is a powerful

More information

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH Product Type LAN Cable Product Family Construction GigaLan Augmented RoHS Compliant Category 6A F/UTP LSZH General Characteristics Features Installation

More information

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter

R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter Test & Measurement Product Brochure 02.00 R&S TS-BCAST DVB-H IP Packet Inserter Compact DVB H signal generator with integrated IP packet inserter R&S TS-BCAST DVB-H IP packet Inserter At a glance The R&S

More information