FIBER OPTICS FIBER OPTIC CABLE FOR VOICE AND DATA TRANSMISSION

Size: px
Start display at page:

Download "FIBER OPTICS FIBER OPTIC CABLE FOR VOICE AND DATA TRANSMISSION"

Transcription

1 OPTICS OPTIC CABLE FOR VOICE AND DATA TRANSMISSION

2 Cable Products This catalog contains in-depth information on the General Cable line of fiber optic cable for voice, video and data transmission. The product and technical sections feature the latest information on fiber optic cable products, from applications and construction to detailed technical and specific data. Our products are readily available through our network of authorized stocking distributors and distribution centers. We are dedicated to customer service and satisfaction so call our team of professionally trained sales personnel to meet your application needs. Cable for the 21 st Century All information in this catalog is presented solely as a guide to product selection and is believed to be reliable. All printing errors are subject to correction in subsequent releases of this catalog. Although General Cable has taken precautions to ensure the accuracy of the product specifications at the time of publication, the specifications of all products contained herein are subject to change without notice. GENERAL CABLE and NEXTGEN are trademarks of General Cable Technologies Corporation. BLOLITE is a trademark of Brand Rex, a Honeywell Security company, and used under license General Cable Technologies Corporation. Highland Heights, KY All rights reserved. Printed in USA.

3 Quality Assurance Policy General Cable is commited to developing, producing and marketing products that exceed the performance, quality, value and safety requirements of our customers by continuously improving all areas of our business. General Cable s goals and objectives reflect this commitment, whether it s through our focus on customer service, continuous improvement and manufacturing excellence demonstrated by our TL9000-registered business management system, the independent third-party certification of our products or the development of new and innovative products. Our aim is to deliver superior performance from all of General Cable s processes and to strive for world-class quality throughout our operations. We recognize that all General Cable associates play a key part in promoting and delivering these objectives and ensuring product and service quality requirements are met. Copies of our current ISO 9001:2000 and TL9000 certificates are shown below, together with an example certified test data report, which accompanies each reel when it leaves the factory. OFNP

4 Table of Contents SECTION PAGES 1 Fiber Specification and Selection 1-2 Fiber Specification and Selection Ordering Information 3 Ordering Information NextGen Brand Fiber-to-the-Premise Cables 4-8 Reduced Diameter Central Tube Drop Cable Central Tube Single Jacket Armored Cable All Dielectric Self-Support Loose Tube Drop Cable Flat Drop Cable All Dielectric Self-Support NextGen Brand Outside Plant Cables 9-16 Central Tube Single Jacket Cable Loose Tube Single Jacket Cable Loose Tube Dual Jacket Cable Loose Tube Single Jacket Armored Cable Loose Tube Dual Jacket Armored Cable Loose Tube Single Jacket Self-Supporting (Figure-8) Cable Loose Tube Single Jacket Armored Self-Supporting (Figure-8) Cable NextGen Brand Premises Cables Tight Buffer Distribution Riser Cable Tight Buffer Distribution Plenum Cable Tight Buffer Breakout Riser Cable Tight Buffer Breakout Plenum Cable Tight Buffer Distribution Low-Smoke, Zero-Halogen (LSZH) Cable Tight Buffer Distribution Interlock Armored Riser Cable Tight Buffer Distribution Interlock Armored Plenum Cable

5 Table of Contents SECTION PAGES 6 NextGen Brand Indoor/Outdoor Cables Central Tube Single Jacket Plenum Cable Loose Tube Single Jacket Plenum Cable Tight Buffer Distribution Riser Cable Tight Buffer Distribution Plenum Cable Central Tube Single Jacket Riser Cable Loose Tube Single Jacket Riser Cable Loose Tube Dual Jacket Riser Cable Chemical-Resistant Loose Tube Single Jacket Low-Smoke, Zero-Halogen (LSZH) Cable Loose Tube Dual Jacket Armored Low-Smoke, Zero-Halogen (LSZH) Cable NextGen Brand Interconnect Cables mm Simplex/Duplex Riser and Plenum Cable mm Simplex/Duplex Riser Cable Ribbon Distribution Riser and Plenum Cable Specialty and Tactical Cable Brand Rex Brand Specialty Cable Tactical Cable Blolite Blolite NextGen Brand Accessories and Assemblies Loose Tube/Central Tube Splitter Kits Loose Tube Breakout Kits Tight Buffer Breakout Kits Factory Installed Terminations Part Number System Technical Information Glossary NEC and CSA Fire Resistance Levels Color Coding Reel Weight and Capacity Chart Part Number Index Notes Blolite is a trademark of Brand Rex, a Honeywell Security company, and used under license.

6 Now one industry leader focuses its worldwide resources on delivering maximum value to customers. It s the cost-effective advantage of a single resource, a single company that provides the broadest product range, the highest level of commitment to customer and technical support, the most cost-effective manufacturing and distribution, and the most responsive customer-first service. In today s highly competitive worldwide markets, General Cable provides the single-source solution with benefits that go straight to your bottom line. Ask your representative about other General Cable products. Energy Cables Industrial & Specialty Cables Communications Cables Bare Overhead High-Voltage Transmission and Distribution Cables Our BICC Brand cables satisfy the varied and specialized demands of the electrical utility marketplace. Our TransPowr bare aluminum overhead cables and PowrMax insulated highvoltage cables for buried applications are available in numerous combinations of aluminum and steel strands and layers. Our new aerial high-density transmission cables feature innovative composite core construction. Low- and Medium-Voltage Distribution Cables General Cable s extensive line of BICC Brand PowrServ and EmPowr copper and aluminum cables serve the total distribution needs of electrical utilities, rural electrical co-ops and the public power market for both traditional and renewable energy resources. Automotive Products From ignition wire sets to battery starter cables and primary wire, our Carol Brand is the answer for the automotive aftermarket. Cord and Mining Cables Carol Brand is the most recognized name in flexible cords. The extensive line includes portable cord, cordsets, portable power cable and premium-grade cable for commercial and industrial applications. Both our Carol and premier Anaconda Brand cables are built for rugged uses such as mining, welding and diesel locomotives. Instrumentation, Power and Control Cables Our industrial and Brand Rex cables serve the factory automation, transit, marine, oil rig, petrochemical and military markets. We manufacture instrumentation tray cables and automation cables for standard, specialized and custom applications. When uptime, reliability and performance are essential, customers count on our power cables from low-voltage single-conductor to mediumvoltage armored or unarmored. Data Communications Cables Our products are on the job wherever enhanced performance is critical from Gigabit Ethernet, token ring and broadband applications to patch panels, communications closets and plenum applications. We offer one of the most comprehensive lines of enhanced high-speed Category products, including GenSPEED 6000 and our PanGen structured cabling system solutions. Electronics Cables Our Carol and Helix/HiTemp Brand products fulfill the complete wire and cable requirements of the fastchanging electronics, sound and security marketplaces. We offer hookup wire; communications cable; computer, coaxial and microphone cables; and special designs for security systems, fire alarms, and audio, video and digital broadcasts. Cables We provide a full menu of NextGen Brand fiber optic cables for data communications and voice and video networks. Our products range from tight buffer and armored products for military applications to loose tube and hybrid cables for communications networks. We also offer advanced Blolite blown fiber systems for Local Area Networks and campus applications. Telecommunications Cables Our broad range of industry-standard outside plant wire and cable products ensures reliable, costeffective performance. We provide air core, filled core and specialty wire products for aerial, buried and duct applications. Wire Harnesses and Assemblies We supply custom-designed cable, harnesses and assemblies for a wide variety of OEM applications, including business machines, material handling equipment, factory automation and medical equipment.

7 Products

8 Fiber Specification and Selection We provide a wide range of optical-fiber options so that our customers have the flexibility to choose a cable plant to best fit their needs. Only optical fiber that meets or exceeds industry standards is used to ensure quality products with best-inclass performance. Fiber options continue to expand as technology demands require improved performance. The information below summarizes the performance of NextGen Brand fiber types. Detailed fiber selection tables are also listed on the following page. 62.5/125 Multimode 62.5/125 multimode has been the TIA/EIA 568B.3 standard in North America and in many parts of the world for years. Proven reliability and strong optical performance has kept this as the fiber of choice for data backbones and recently, Fiber-To-The- Desk (FTTD). Super/FDDI - This fiber meets the bandwidth requirement and exceeds the attenuation specification for TIA/EIA 568B.3. G300 - The G300 fiber has an optimized core profile that allows it to efficiently transmit a Gigabit Ethernet (per IEEE 802.3z) laser signal 300 meters at 850nm and 550 meters at 1300nm. In addition, this fiber maintains backward compatiblity with TIA/EIA 568B.3 and ISO It is perfect for any network backbone that reaches to 300 meters and for centralized cabling topographies. G500 - The G500 is a premium 62.5/125 multimode fiber optimized for performance in laser-based systems such as Gigabit Ethernet. G500 can transmit a Gigabit Ethernet (per IEEE 802.3z) laser signal a distance of 500 meters at 850nm and 1000 meters at 1300nm. This fiber provides a great solution as backbone distances increase and the bandwidth potential of 1 Gb/s systems is utilized. This fiber also meets the requirement of TIA/EIA 568B.3 and ISO /125 Multimode 50/125 multimode has been a standard in ISO and is used primarily in Europe and Asia. The popularity of 50/125 around the world and its superior bandwidth performance in the 850nm window are driving its inclusion into TIA/EIA 568B.3 and acceptance in North America. 50/125 multimode is fully compatible with 62.5/125 fiber and components. Compared to 62.5/125 fiber, 50/125 provides higher bandwidth at a lower cost. Singlemode G600 - G600 was designed to meet or exceed all requirements of TIA/EIA 568B.3 and ISO Additionally, G600 can extend the signal transmission distance of a Gigabit Ethernet (per IEEE 802.3Z) laser signal to 600 meters at both 850nm and 1300nm. G10X - G10X optical fiber is engineered for laser-based protocols IEEE 802.3ae such as Gigabit Ethernet and 10 Gigabit Ethernet while maintaining compatibility with Ethernet, Fast Ethernet and ATM protocols. Singlemode fiber s tremendous bandwidth and low attenuation has made it the fiber of choice for service carriers. As opto-electronics come down in price, singlemode is becoming more common in data communication networks. We offer non-dispersion shifted singlemode fiber, TIA/EIA 492AAAA Class IVa, as a standard offering. Our singlemode fiber complies with the ITU G-652 standard. Premium - The premium grade of fiber has a maximum fiber attenuation of 0.4/0.3 db/km at 1310/1550nm for each fiber in a loose tube cable. This is most common for outside plant applications where transmission distances and loss budgets are critical. Super - This grade is most effective with premises and indoor/outdoor cables where the transmission distances are short (< 5km). The super grade of singlemode fiber has an attenuation of 1.0/1.0 db/km at 1310/1550nm for tight buffer cables. Other grades of 62.5/125, 50/125, Non-Zero Dispersion Shifted (NZDS) singlemode fibers and enhanced singlemode fibers are available to suit design preferences and industry standards. These fibers are described in the tables on page 2. 1

9 Fiber Specification and Selection Fiber Specification and Selection Optical Characteristics: Maximum Finished Cable Attenuation Coefficient Overfill Launch Bandwidth Laser Bandwidth Gigabit Ethernet Link Length (1 Gbps) Ten Gigabit Ethernet Length (10 Gbps) MULTIMODE SELECTION GUIDE 50/125 PRODUCT FAMILY 62.5/125 PRODUCT FAMILY Type-BG Type-BI Type-BE Type-BL Type-CG Type-CL MHz.km 1000BASE-SX meters 1000BASE-LX meters 10GBASE-SR meters DESCRIPTION TYPE SINGLE-MODE SELECTION GUIDE MAXIMUM ATTENUATION (db/km) 1310nm 1550nm GIGABIT ETHERNET DISTANCE (METERS) 1310nm 10 GIGABIT ETHERNET DISTANCE (METERS) 1310nm 1550nm Singlemode - Loose Tube Super AP ,000 5,000 30,000 Premium AQ ,000 5,000 30,000 High Performance AT ,000 5,000 30,000 Singlemode - Tight Buffer Super AP ,000 5,000 30,000 SPECIALTY S - SINGLEMODE TYPICAL ATTENUATION (db/km) DESCRIPTION TYPE 1310nm 1383nm 1550nm 1605nm 1625nm TYPICAL APPLICATION Singlemode (NZDS) High Data Rate AM WDM & 10 Gb/s Large Effective Area AL DWDM Singlemode 5 (band) Extended Band AE CWDM Use the code in the Fiber Type column to replace the XX notation in the catalog number shown on the catalog page. This identifies the fiber that will be provided with the cable choice. The fibers in all completed cables are tested 100% at the factory for attenuation and each fiber must meet the minimum requirements specified by the customer. 2

10 Ordering Information Ordering Information We strive to have a variety of cables in stock for immediate delivery to our customers. Should the cable not be in stock, it will be manufactured to your specifications. To choose a fiber optic cable you need to know the following: 1) What type and grade of fiber is required? The system designer will have identified the fiber that is required for the network. Find the fiber type that is needed from the Fiber Specification and Selection Guide. Use the two-digit NextGen Fiber Type code to identify the fiber. This code becomes the first two digits of the catalog part number, replacing the XX notation. 2) How many fibers are required? The system designer will also have identified the number of fibers that will be in each cable. Fibers are usually cabled in groups of 6 or 12. 3) What cable construction is needed? The cable construction that is needed is based on a variety of factors. We have a full range of products for premises, outside plant and indoor/outdoor to solve nearly every application need. Using the catalog as a guide, identify the cable type and construction that is needed. With the cable construction decided, move down the table on the catalog page to find the number of fibers required. The first column of that row is the catalog part number. Simply replace the XX at the beginning of the catalog number shown with the Fiber Type code found in number one and the part number is complete Part Number System Jacket Type: A) Polyethylene; B) PVC (General Purpose); C) Polyurethane; D) PVDF-Plenum; E) CPE; F) Single Armor/PE; G) Single Armor/PVC; H) PE/Nylon; J) Double Armor (Alum./Steel); L) Single Armor, Zero-Halogen; M) Loose Tube Riser; N) Single Armor Fig 8; P) PVDF/Armor; Q) Alum. Armor; R) Riser Grade PVC; S) Double Armor (Steel); T) FEP Teflon/Tefzel; U) Soft Plenum; V) Loose Tube Riser Armored; X) Special - Specify; Y) Non-Armored Fig 8; Z) Zero-Halogen. Central Strength Member: 1) Dielectric; 2) Steel; 3) Aramid Yarn (Up-Jacketed); N) None; X) Special - Specify. Cable Construction: A) Dry Water Block - Premise; B) Breakout; H) Heavy Duty (Outdoor); K) Buffered Fiber; M) Medium Service (Duct); P) Premise; S) Simplex; U) Single Tube Outdoor (Aerial/Burial); Z) Zipcord; X) Special - Specify. Buffer Construction: 1) Tight Buffer; 2) Quick Strip; 3) Single Fiber Loose Tube (Gel-Filled); 4) Multi-Fiber Loose Tube (Gel- Filled); 5) Loose Buffer; 6) Bare/Ribbon. Number of Fibers: 001) 1; 002) 2; 004) 4; 006) 6; 008) 8; 010) 10; 012) 12 (up to 288 fiber in some cable constructions). Fiber Grade: See Fiber Specification and Selection. Fiber Size: A) SM; B) 50µm; C) 62.5µm; E) 100µm; F) 200µm; G) 200/230µm; J) 200/230µm HCS; XX) Special - Specify. Example: A 6 Fiber 50/125µm G600 grade Riser/Breakout cable would have a part number BG0061B3R. Hybrid Cables (SM/MM) Example: A 12 Fiber Tight Buffer Distribution Plenum cable with 6SM and 6MM Fibers would have the part number AP006/CG0061PNU. NOTE: For Interlock Armored Premise Plenum Cables, add -ILPA to the end of the part number. For Interlock Armored Premise Riser cables, add -ILRA to the end of the part number. For Dry Water Blocked Aerial/Burial/Duct cables, add -DWB to the end of the part number. For cables with Dry Loose Tubes, add -DT to the end of the part number. 3

11 NextGen Brand Fiber-to-the-Premise Cables Index Page We are pleased to introduce our new line of NextGen Brand Fiber-to-the-Premise cables. As fiber optics becomes the preferred transmission media, innovative cable designs are necessary to reduce installation time and save money. That is why we have developed a complete line of new fiber optic cable designs for Fiber-to-the- Premise applications. Applications: NextGen Fiberto-the-Premise cables with loose tube constructions are built to withstand adverse environments and provide the maximum fiber protection. These cables perform exceptionally well in wet conditions and during extreme temperature cycles. Various constructions are available for installation in ducts, direct buried, aerial/lashed and aerial/self-support. NextGen Fiber-to-the-Premise cables are specifically designed to be small in size and lightweight for ease of installation. Range of Products: A wide range of cables from 2-12 fibers are manufactured with a variety of designs to meet the demands of most installation conditions. Features: Only the highestquality materials are used in NextGen fiber optic cables to ensure that the cable strength and optical integrity are not compromised. Rugged jacket materials and the addition of armor provide the right level of protection. The line of outside plant products conform to TIA/EIA, ICEA, Telcordia and RUS standards. As with all NextGen fiber optic cables, splitter kits are available to reinforce and assist in preparing the fibers for termination. Reduced Diameter Central Tube Drop Cable 5 Central Tube Single Jacket Armored Cable 6 All Dielectric Self-Support Loose Tube Drop Cable 7 Flat Drop Cable All Dielectric Self-Support 8 4

12 Reduced Diameter Central Tube Drop Cable Fiber-to-the-Premise Product Construction: Fiber: 2-12 fibers Central gel-filled tube Color-coding per TIA/EIA 598B Overall Strength Member: Aramid fiber yarn or fiberglass COUNT LOOSE TUBES DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Jacket: Black UV- and moisture-resistant polyethylene (PE) Sequential footage markings* XX0024UNA7.1 XX0044UNA7.1 XX0064UNA7.1 XX0084UNA7.1 XX0124UNA7.1 XX Denotes fiber type Typical Cross-Section (7.1) 39 (58) 300 (1334) 100 (445) (7.1) 39 (58) 300 (1334) 100 (445) (7.1) 39 (58) 300 (1334) 100 (445) (7.1) 39 (58) 300 (1334) 100 (445) (7.1) 39 (58) 300 (1334) 100 (445) PE Jacket Overall Strength Member (Dry Water Block) Central Tube Fiber Features: All dielectric, lightweight and flexible Compact, user-friendly design Loose tube construction provides environmental protection Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 150 lbs/in (263 N/cm) Applications: Interbuilding voice or data communication backbones Installed in ducts, underground conduit or aerial/lashed FTTX Compliances: ANSI/TIA/EIA 568B.3 GR-20 Accessories: SPK splitter kits are suitable for Reduced Diameter Central Tube Cables *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm Premium G300 AQ /0.3 CG /1.0 5

13 Fiber-to-the-Premise Central Tube Single Jacket Armored Cable Product Construction: Fiber: 2-12 fibers Central tube gel-filled Color-coding per TIA/EIA 598B Overall Strength Member: Aramid fiber yarn or fiberglass Armor: 0.006" corrugated coated steel tape Outer Jacket: Black UV- and moisture-resistant polyethylene (PE) Sequential footage markings* Features: Compact, user-friendly design Central tube armored design provides excellent fiber protection Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 150 lbs/in (440 N/cm) Applications: Interbuilding voice or data communication backbones Installed in ducts, underground conduits, aerial/lashed or direct buried FTTX Compliances: ANSI/TIA/EIA 568B.3 GR-20 Accessories: SPK splitter kits are suitable for Central Tube Single Jacket Armored Cables XX0024UNFS XX0044UNFS XX0064UNFS XX0084UNFS XX0124UNFS XX Denotes fiber type Typical Cross-Section 6 Fiber COUNT LOOSE TUBES (8.5) 64 (95) 600 (2670) 200 (890) (8.5) 64 (95) 600 (2670) 200 (890) (8.5) 64 (95) 600 (2670) 200 (890) (8.5) 64 (95) 600 (2670) 200 (890) (8.5) 64 (95) 600 (2670) 200 (890) Outer PE Jacket Armor Central Tube Overall Strength Member (Dry Water Block) Fiber DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm Premium G300 AQ /0.3 CG /1.0 6

14 All Dielectric Self-Support Loose Tube Drop Cable Fiber-to-the-Premise Product Construction: Fiber: 2-12 fibers Central gel-filled tube Color-coding per TIA/EIA 598B Strength Member: Epoxy/glass rod COUNT LOOSE TUBES DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Jacket: Black UV- and moisture-resistant polyethylene (PE) or flame-retardant PVC Sequential footage markings* XX0024U1A XX0044U1A XX0064U1A XX0084U1A XX0124U1A XX Denotes fiber type Typical Cross-Section (9.4) 43 (64) 300 (1334) 100 (445) (9.4) 43 (64) 300 (1334) 100 (445) (9.4) 43 (64) 300 (1334) 100 (445) (9.4) 43 (64) 300 (1334) 100 (445) (9.4) 43 (64) 300 (1334) 100 (445) PE Jacket Overall Strength Member (Dry Water Block) Central Tube Fiber Dielectric Strength Members Features: All dielectric self-supporting Compact, user-friendly design Loose tube construction provides environmental protection Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 150 lbs/in (263 N/cm) Applications: Interbuilding voice or data communication backbones Installed in ducts, underground conduit or aerial/lashed FTTX Compliances: ANSI/TIA/EIA 568B.3 GR-20 Accessories: SPK splitter kits are suitable for All Dielectric Self-Support Loose Tube Drop Cables *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm Premium G300 AQ /0.3 CG /1.0 7

15 Fiber-to-the-Premise Flat Drop Cable All Dielectric Self-Support Product Construction: Fiber: 2-12 fibers Central gel-filled tube Color-coding per TIA/EIA 598B Strength Member: (2) Epoxy/glass rod Jacket: Black UV- and moisture-resistant polyethylene (PE) or flame-retardant PVC Sequential footage markings* Features: All dielectric self-supporting Compact, user-friendly design Loose tube construction provides environmental protection Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 15 X OD In-Service Maximum Crush Resistance: 150 lbs/in (263 N/cm) Applications: Interbuilding voice or data communication backbones Installed in ducts, underground conduit or aerial/lashed FTTX Compliances: ANSI/TIA/EIA 568B.3 GR-20 Accessories: SPK splitter kits are suitable for Flat Drop Cable All Dielectric Self-Support *Sequential meter markings available upon request XX0014U1AF XX0024U1AF XX0044U1AF XX0064U1AF XX0084U1AF XX0124U1AF XX Denotes fiber type LOOSE COUNT TUBES Typical Cross-Section DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) x.175 (8.1 x 4.4) 33 (49) 300 (1334) 100 (445) x.175 (8.1 x 4.4) 33 (49) 300 (1334) 100 (445) x.175 (8.1 x 4.4) 33 (49) 300 (1334) 100 (445) x.175 (8.1 x 4.4) 33 (49) 300 (1334) 100 (445) x.175 (8.1 x 4.4) 33 (49) 300 (1334) 100 (445) x.175 (8.1 x 4.4) 33 (49) 300 (1334) 100 (445) PE Jacket DWB Glass Strength Member Dielectric FRP Rods Loose Tube 1 or 2 Fibers A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm Premium G300 AQ /0.3 CG /1.0 8

16 NextGen Brand Outside Plant Cables Index Page NextGen Brand fiber optic cable is right for any outside plant application. Applications: Outside plant cables with loose tube constructions are built to withstand adverse environments and provide the maximum fiber protection. These cables perform exceptionally well in wet conditions and during extreme temperature cycles. They can be installed in ducts, direct buried and aerial/lashed providing the flexibility needed to meet the demands of campus backbones and other outside plant requirements. Range of Products: A wide range of cables from fibers are manufactured with a variety of designs to meet the demands of most installation conditions. Features: Only the highestquality materials are used in NextGen fiber optic cables to ensure that the cable strength and optical integrity are not compromised. Rugged jacket materials and the addition of armor provide the right level of protection. The line of outside plant products conform to TIA/EIA, ICEA, Telcordia and RUS standards. As with all NextGen fiber optic cables, splitter kits are available to reinforce and assist in preparing the fibers for termination. Central Tube Single Jacket Cable 10 Loose Tube Single Jacket Cable 11 Loose Tube Dual Jacket Cable 12 Loose Tube Single Jacket Armored Cable 13 Loose Tube Dual Jacket Armored Cable 14 Loose Tube Single Jacket Self-Supporting (Figure-8) Cable 15 Loose Tube Single Jacket Armored Self-Supporting (Figure-8) Cable 16 9

17 Outside Plant Cables Central Tube Single Jacket Cable Product Construction: Fiber: 2-12 fibers Central gel-filled tube Color-coding per TIA/EIA 598B Overall Strength Member: Aramid fiber yarn or fiberglass Jacket: Black UV- and moisture-resistant polyethylene (PE) Sequential footage markings* COUNT LOOSE TUBES DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Features: Very lightweight and flexible Compact, user-friendly design Loose tube construction provides environmental protection Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 150 lbs/in (263 N/cm) Applications: Interbuilding voice or data communication backbones Installed in ducts, underground conduit or aerial/lashed Compliances: ANSI/TIA/EIA 568B.3 ICEA S ETL Verified GR-20 Verified Accessories: SPK splitter kits are suitable for Central Tube Single Jacket Cables XX0024UNA XX0044UNA XX0064UNA XX0084UNA XX0124UNA XX Denotes fiber type Typical Cross-Section (8.6) 40 (59) 600 (2670) 200 (890) (8.6) 40 (59) 600 (2670) 200 (890) (8.6) 40 (59) 600 (2670) 200 (890) (8.6) 40 (59) 600 (2670) 200 (890) (8.6) 40 (59) 600 (2670) 200 (890) PE Jacket Overall Strength Member (Dry Water Block) Central Tube Fiber *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm Premium G300 AQ /0.3 CG /1.0 10

18 Loose Tube Single Jacket Cable Outside Plant Cables XX0023M1A-DWB XX0044M1A-DWB XX0064M1A-DWB XX0084M1A-DWB XX0124M1A-DWB XX0184M1A-DWB XX0244M1A-DWB XX0364M1A-DWB XX0484M1A-DWB XX0604M1A-DWB XX0724M1A-DWB XX0964M1A-DWB XX1204M1A-DWB XX1444M1A-DWB XX1924M1A-DWB XX2164M1A-DWB XX2404M1A-DWB XX2644M1A-DWB XX2884M1A-DWB XX Denotes fiber type COUNT LOOSE TUBES FILLERS Typical Cross-Section DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) (11.1) 52.0 (78.0) 600 (2670) 180 (800) (11.1) 52.0 ( 78.0) 600 (2670) 180 (800) (11.1) 52.0 ( 78.0) 600 (2670) 180 (800) (11.1) 52.0 ( 78.0) 600 (2670) 180 (800) (11.1) 52.0 ( 78.0) 600 (2670) 180 (800) (11.1) 52.0 ( 78.0) 600 (2670) 180 (800) (11.1) 52.0 ( 78.0) 600 (2670) 180 (800) (11.1) 52.0 ( 78.0) 600 (2670) 180 (800) (11.1) 52.0 ( 78.0) 600 (2670) 180 (800) (11.1) 52.0 ( 78.0) 600 (2670) 180 (800) (12.0) 62.0 (93.0) 600 (2670) 180 (800) (13.7) 78.0 (118.0) 600 (2670) 180 (800) (15.4 ) (150.0) 600 (2670) 180 (800) (17.3) (187.0) 600 (2670) 180 (800) (17.6) (176.0) 600 (2670) 180 (800) (17.6) (176.0) 600 (2670) 180 (800) (19.0) (210.0) 600 (2670) 180 (800) (19.0) (210.0) 600 (2670) 180 (800) (20.0) (235.0) 600 (2670) 180 (800) PE Jacket Overall Strength Member Loose Tube MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Product Construction: Fiber: fibers Loose tube gel-filled Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/Glass Rod Overall Strength Member: Aramid fiber yarn or fiberglass Jacket: Black UV- and moisture-resistant polyethylene (PE) Sequential footage markings* Features: Loose tube gel-filled construction for superior fiber protection UV- and moisture-resistant design Dry water block cable core for ease of handling Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 125 lbs/in (220 N/cm) Applications: Interbuilding voice or data communication backbones Installed in ducts, underground conduit or aerial/lashed Compliances: ANSI/TIA/EIA 568B.3 ICEA S ETL Verified Rural Utilities Service (RUS) 7 CFR (REA PE-90) GR-20 Verified Accessories: SPK splitter kits are suitable for Loose Tube Single Jacket Cables *Sequential meter markings available upon request Fiber Central Strength Member Dry Water Block Material 36 Fiber A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm Premium G300 AQ /0.3 CG /1.0 11

19 Outside Plant Cables Loose Tube Dual Jacket Cable Product Construction: Fiber: fibers Loose tube gel-filled Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/glass rod Overall Strength Member: Aramid fiber yarn or fiberglass Inner Jacket: Black UV- and moisture-resistant polyethylene (PE) Outer Jacket: Black UV- and moisture-resistant polyethylene (PE) Sequential footage markings* Features: Loose tube gel-filled construction for superior fiber protection UV- and moisture-resistant design Added protection of an inner jacket Dry water block cable core for ease of handling Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 125 lbs/in (220 N/cm) Applications: Interbuilding voice or data communication backbones Installed in ducts, underground conduits, aerial/lashed or direct buried Compliances: ANSI/TIA/EIA 568B.3 ICEA S ETL Verified Rural Utilities Service (RUS) 7 CFR (REA PE-90) GR-20 Verified Accessories: SPK splitter kits are suitable for Loose Tube Dual Jacket Cables *Sequential meter markings available upon request XX0023H1A-DWB XX0044H1A-DWB XX0064H1A-DWB XX0084H1A-DWB XX0124H1A-DWB XX0184H1A-DWB XX0244H1A-DWB XX0364H1A-DWB XX0484H1A-DWB XX0604H1A-DWB XX0724H1A-DWB XX0964H1A-DWB XX1204H1A-DWB XX1444H1A-DWB XX1924H1A-DWB XX2164H1A-DWB XX2404H1A-DWB XX2644H1A-DWB XX2884H1A-DWB XX Denotes fiber type COUNT LOOSE TUBES FILLERS Typical Cross-Section (13.0) 76.0 ( 113.1) 600 (2670) 200 (890) (13.0) 76.0 ( 113.1) 600 (2670) 200 (890) (13.0) 76.0 ( 113.1) 600 (2670) 200 (890) (13.0) 76.0 ( 113.1) 600 (2670) 200 (890) (13.0) 76.0 (113.1) 600 (2670) 200 (890) (13.0) 76.6 (114.0) 600 (2670) 200 (890) (13.0) 76.6 (114.0) 600 (2670) 200 (890) (13.0) 77.2 ( (2670) 200 (890) (13.0) 77.8 ( (2670) 200 (890) (13.0) 77.8 (115.8) 600 (2670) 200 (890) (13.7) 90.0 (133.9) 600 (2670) 200 (890) (15.4) (165.2) 600 (2670) 200 (890) (2670) 200 (890) (19.0) (249.0) 600 (2670) 200 (890) (2670) 200 (890) (19.3) (241.2) 600 (2670) 200 (890) (2670) 200 (890) (2670) 200 (890) (2670) 200 (890) Outer PE Jacket Overall Strength Member Inner PE Jacket Loose Tube Fiber DIAMETER in (mm) Central Strength Member WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) 36 Fiber Dry Water Block Material A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm Premium G300 AQ /0.3 CG /1.0 12

20 Loose Tube Single Jacket Armored Cable Outside Plant Cables XX0023M1F-DWB XX0044M1F-DWB XX0064M1F-DWB XX0084M1F-DWB XX0124M1F-DWB XX0184M1F-DWB XX0244M1F-DWB XX0364M1F-DWB XX0484M1F-DWB XX0604M1F-DWB XX0724M1F-DWB XX0964M1F-DWB XX1204M1F-DWB XX1444M1F-DWB XX1924M1F-DWB XX2164M1F-DWB XX2404M1F-DWB XX2644M1F-DWB XX2884M1F-DWB XX Denotes fiber type COUNT LOOSE TUBES FILLERS Typical Cross-Section (12.1) (190.0) 600 (2670) 125 (220) (12.1) (190.0) 600 (2670) 125 (220) (12.1) (190.0) 600 (2670) 125 (220) (12.1) (190.0) 600 (2670) 125 (220) (12.1) (190.0) 600 (2670) 125 (220) (12.1) (190.0) 600 (2670) 125 (220) (12.1) (190.0) 600 (2670) 125 (220) (12.1) (190.0) 600 (2670) 125 (220) (12.1) (190.0) 600 (2670) 125 (220) (12.1) (190.0) 600 (2670) 125 (220) (13.6) (212.0) 600 (2670) 125 (220) (15.3) (252.0) 600 (2670) 125 (220) (17.2) (299.0) 600 (2670) 125 (220) (19.1) (348.0) 600 (2670) 125 (220) (19.4) (343.0) 600 (2670) 125 (220) (19.4) (343.0) 600 (2670) 125 (220) (20.7) (385.0) 600 (2670) 125 (220) (20.7) (385.0) 600 (2670) 125 (220) (21.7) (419.0) 600 (2670) 125 (220) Outer PE Jacket Armor Loose Tube Fiber DIAMETER in (mm) Central Strength Member WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Product Construction: Fiber: fibers Loose tube gel-filled Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/Glass Rod Overall Strength Member: Aramid fiber yarn or fiberglass Armor: 0.006" corrugated coated steel tape Outer Jacket: Black UV- and moisture-resistant polyethylene (PE) Sequential footage markings* Features: Loose tube gel-filled construction for superior fiber protection UV- and moisture-resistant design Rodent-proof construction Dry water block cable core for ease of handling Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 125 lbs/in (220 N/cm) Applications: Interbuilding voice or data communication backbones Installed in ducts, underground conduits, aerial/lashed or direct buried Compliances: ANSI/TIA/EIA 568B.3 ICEA S ETL Verified Rural Utilities Service (RUS) 7 CFR (REA PE-90) GR-20 Verified Accessories: SPK splitter kits are suitable for Loose Tube Single Jacket Armored Cables *Sequential meter markings available upon request Dry Water Block Material 36 Fiber A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm Premium G300 AQ /0.3 CG /1.0 13

21 Outside Plant Cables Loose Tube Dual Jacket Armored Cable Product Construction: Fiber: fibers Loose tube gel-filled Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/glass rod Overall Strength Member: Aramid fiber yarn or fiberglass Inner Jacket: Black UV- and moisture-resistant polyethylene (PE) Armor: 0.006" corrugated coated steel tape Outer Jacket: Black UV- and moisture-resistant polyethylene (PE) Sequential footage markings* Features: Loose tube gel-filled construction for superior fiber protection UV- and moisture-resistant design Rodent-proof construction Dry water block cable core for ease of handling Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 125 lbs/in (220 N/cm) Applications: Interbuilding voice or data communication backbones Installed in ducts, underground conduits, aerial/lashed or direct buried Compliances: ANSI/TIA/EIA 568B.3 ICEA S ETL Verified Rural Utilities Service (RUS) 7 CFR (REA PE-90) GR-20 Verified Accessories: SPK splitter kits are suitable for Loose Tube Dual Jacket Armored Cables *Sequential meter markings available upon request XX0023H1F-DWB XX0044H1F-DWB XX0064H1F-DWB XX0084H1F-DWB XX0124H1F-DWB XX0184H1F-DWB XX0244H1F-DWB XX0364H1F-DWB XX0484H1F-DWB XX0604H1F-DWB XX0724H1F-DWB XX0964H1F-DWB XX1204H1F-DWB XX1444H1F-DWB XX1924H1F-DWB XX2164H1F-DWB XX2404H1F-DWB XX2644H1F-DWB XX2884H1F-DWB XX Denotes fiber type COUNT LOOSE TUBES FILLERS Typical Cross-Section 36 Fiber (13.9) (163.8) 600 (2670) 180 (800) (13.9) (163.3) 600 (2670) 180 (800) (13.9) (163.5) 600 (2670) 180 (800) (13.9) (164.2) 600 (2670) 180 (800) (13.9) (164.5) 600 (2670) 180 (800) (13.9) (165.5) 600 (2670) 180 (800) (13.9) (166.5) 600 (2670) 180 (800) (14.5) (185.6) 600 (2670) 180 (800) (15.4) (197.4) 600 (2670) 180 (800) (15.4) (198.9) 600 (2670) 180 (800) (16.3) (230.2) 600 (2670) 180 (800) (18.2) (273.7) 600 (2670) 180 (800) (19.9) (348.4) 600 (2670) 180 (800) (21.6) (392.3) 600 (2670) 180 (800) (22.3) (385.6) 600 (2670) 180 (800) (22.3) (388.5) 600 (2670) 180 (800) (27.6) (575.9) 600 (2670) 180 (800) (27.6) (577.0) 600 (2670) 180 (800) (27.6) (580.1) 600 (2670) 180 (800) Outer PE Jacket Armor Inner PE Jacket Loose Tube Fiber DIAMETER in (mm) Central Strength Member Dry Water Block Material WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm Premium G300 AQ /0.3 CG /1.0 14

22 Outside Plant Cables Loose Tube Single Jacket Self-Supporting (Figure-8) Cable XX0023M1Y-DWB XX0044M1Y-DWB XX0064M1Y-DWB XX0084M1Y-DWB XX0124M1Y-DWB XX0184M1Y-DWB XX0244M1Y-DWB XX0364M1Y-DWB XX0484M1Y-DWB XX0604M1Y-DWB XX0724M1Y-DWB XX0964M1Y-DWB XX1204M1Y-DWB XX1444M1Y-DWB XX Denotes fiber type COUNT LOOSE TUBES FILLERS Typical Cross-Section 36 Fiber " x 0.92" (11.8 x 23.45) (310) 600 (2670) 180 (800) " x 0.92" (11.8 x 23.45) (310) 600 (2670) 180 (800) " x 0.92" (11.8 x 23.45) (310) 600 (2670) 180 (800) " x 0.92" (11.8 x 23.45) (310) 600 (2670) 180 (800) " x 0.92" (11.8 x 23.45) (310) 600 (2670) 180 (800) " x 0.92" (11.8 x 23.45) (310) 600 (2670) 180 (800) " x 0.92" (11.8 x 23.45) (310) 600 (2670) 180 (800) " x 0.92" (11.8 x 23.45) (310) 600 (2670) 180 (800) " x 0.92" (11.8 x 23.45) (310) 600 (2670) 180 (800) " x 0.92" (11.8 x 23.45) (310) 600 (2670) 180 (800) " x 0.96" (12.65 x 24.3) (323) 600 (2670) 180 (800) " X 1.03" (14.4 X 26.0) (351) 600 (2670) 180 (800) " X 1.16" (17.7 X 29.35) (425) 600 (2670) 180 (800) " X 1.16" (17.7 X 29.35) (425) 600 (2670) 180 (800) 1/4" Steel Messenger PE Jacket Overall Strength Member Loose Tube Fiber Central Strength Member Dry Water Block Material DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Product Construction: Fiber: fibers Loose tube gel-filled Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/glass rod Overall Strength Member: Aramid fiber yarn or fiberglass Jacket: Black UV- and moisture-resistant polyethylene (PE) Sequential footage markings* Messenger Wire: 1/4" stranded EHS galvanized steel Features: Loose tube gel-filled construction for superior fiber protection UV- and moisture-resistant design Self-supporting figure-8 design Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 125 lbs/in (220 N/cm) Applications: Interbuilding voice or data communication backbones Installed aerially Compliances: ANSI/TIA/EIA 568B.3 ICEA S ETL Verified Rural Utilities Service (RUS) 7 CFR (REA PE-90) GR-20 Accessories: SPK splitter kits are suitable for Loose Tube Single Jacket Self-Supporting (Figure-8) Cables Installation Notes: The Maximum Tensile Load in the data table refers to the cable core only. Users should base sag and tension calculations on 1/4" EHS messenger per local guidelines and practices. Additional data is available from General Cable. *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm Premium G300 AQ /0.3 CG /1.0 15

23 Outside Plant Cables Loose Tube Single Jacket Armored Self-Supporting (Figure-8) Cable Product Construction: Fiber: fibers Loose tube gel-filled Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/glass rod Overall Strength Member: Aramid fiber yarn or fiberglass Inner Jacket: Black UV- and moisture-resistant polyethylene (PE) Armor: 0.006" corrugated coated steel tape Outer Jacket: Black UV- and moisture-resistant polyethylene (PE) Sequential footage markings* Messenger Wire: 1/4" stranded EHS galvanized steel Features: Loose tube gel-filled construction for superior fiber protection UV- and moisture-resistant design Self-supporting figure-8 design Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 125 lbs/in (220 N/cm) Applications: Interbuilding voice or data communication backbones Installed aerially Compliances: ANSI/TIA/EIA 568B.3 ICEA S ETL Verified Rural Utilities Service (RUS) 7 CFR (REA PE-90) GR-20 Verified Accessories: SPK splitter kits are suitable for Loose Tube Dual Jacket Armored Self-Supporting (Figure-8) Cables XX0023M1N-DWB XX0044M1N-DWB XX0064M1N-DWB XX0084M1N-DWB XX0124M1N-DWB XX0184M1N-DWB XX0244M1N-DWB XX0364M1N-DWB XX0484M1N-DWB XX0604M1N-DWB XX0724M1N-DWB XX0964M1N-DWB XX1204M1N-DWB XX1444M1N-DWB XX Denotes fiber type Typical Cross-Section 36 Fiber COUNT LOOSE TUBES FILLERS " x 0.93" (11.9 x 23.55) 237 (352) 600 (2670) 180 (800) " x 0.93" (11.9 x 23.55) 237 (352) 600 (2670) 180 (800) " x 0.93" (11.9 x 23.55) 237 (352) 600 (2670) 180 (800) " x 0.93" (11.9 x 23.55) 237 (352) 600 (2670) 180 (800) " x 0.93" (11.9 x 23.55) 237 (352) 600 (2670) 180 (800) " x 0.93" (11.9 x 23.55) 237 (352) 600 (2670) 180 (800) " x 0.93" (11.9 x 23.55) 237 (352) 600 (2670) 180 (800) " x 0.93" (11.9 x 23.55) 237 (352) 600 (2670) 180 (800) " x 0.93" (11.9 x 23.55) 237 (352) 600 (2670) 180 (800) " x 0.93" (11.9 x 23.55) 237 (352) 600 (2670) 180 (800) " x 0.99" (13.6 x 25.25) 255 (379) 600 (2670) 180 (800) " X 1.06" (15.3 X 26.95) 275 (409) 600 (2670) 180 (800) " X 1.21" (19.1 X 30.75) 339 (505) 600 (2670) 180 (800) " X 1.21" (19.1 X 30.75) 339 (505) 600 (2670) 180 (800) Messenger Wire Outer Jacket Steel Armor Loose Tube Component Fillers (if applicable) DIAMETER in Super Absorbent Tape Outer Strength Member (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Installation Notes: The Maximum Tensile Load in the data table refers to the cable core only. Users should base sag and tension calculations on 1/4" EHS messenger per local guidelines and practices. Additional data is available upon request. *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm Premium G300 AQ /0.3 CG /1.0 16

24 NextGen Brand Premises Cables Index Page NextGen Brand fiber optic cable is right for any premises application. Applications: Premises cables with 900µm tight buffer constructions are built to withstand the continuous handling and difficult routing typical of building backbones. These fiber optic cables emphasize flexibility, handling and proper fiber termination characteristics. This provides reliable and simple installations every time. These cables are used for intrabuilding vertical (backbone) and horizontal runs. Range of Products: Includes the manufacture of riser, plenum and Low-Smoke, Zero- Halogen (LSZH) cables. This includes distribution designs as well as breakout style cables. Fiber counts range up to 144 fibers. Features: Premises cables have an industry-standard 900µm tight buffer for termination to connectors. The tight buffer diameter is tightly controlled to provide reliable, first-time connections. Breakout cables utilize 2.4mm breakout dimensions for rugged environments and compatibility with connectors. All fibers are color-coded and subgrouped (if necessary) for easy identification for handling. As with all NextGen Brand fiber optic cables, breakout kits are available for premises cables to reinforce and assist in preparing the fibers for termination. Tight Buffer Distribution Riser Cable 18 Tight Buffer Distribution Plenum Cable 19 Tight Buffer Breakout Riser Cable 20 Tight Buffer Breakout Plenum Cable 21 Tight Buffer Distribution Low-Smoke, Zero-Halogen (LSZH) Cable 22 Tight Buffer Distribution Interlock Armored Riser Cable 23 Tight Buffer Distribution Interlock Armored Plenum Cable 24 17

25 Premises Cables Tight Buffer Distribution Riser Cable Type OFNR, CSA FT-4 Product Construction: Fiber: fibers 900µm tight buffer Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/glass rod (above 12 fibers) Overall Strength Member: Aramid fiber yarn Jacket: Flame-retardant polyvinyl chloride (PVC) Sequential footage markings* Orange Jacket Multimode fibers (except 10 Gbps) Aqua Jacket 10 Gbps Multimode fibers Yellow Jacket Singlemode fibers Features: Lightweight, flexible design simplifies installation Tight buffer provides individual fiber protection Tight buffered fibers are easy to handle and strip for field connectorization Sub-units are numbered for identification Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -20 C (-4 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 850 lbs/in (1485 N/cm) Maximum Vertical Rise 1,640 ft (500 m) Applications: Intrabuilding voice or data communication backbones UL Listed Type OFNR for installation in vertical riser and general horizontal applications when installed in accordance with NEC article (b) and (b) Compliances: UL and c(ul) Listed Type OFNR CSA FT-4 ANSI/TIA/EIA 568B.3 ICEA S ETL Verified GR-409 Accessories: BOKP breakout kits are suitable for Tight Buffer Distribution Riser Cables *Sequential meter markings available upon request XX0021PNR XX0041PNR XX0061PNR XX0081PNR XX0101PNR XX0121PNR XX0181P1R XX0241P1R XX0361P1R XX0481P1R XX0601P1R XX0721P1R XX0961P1R XX1201P1R XX1441P1R XX Denotes fiber type Typical Cross-Section Flame-Retardant Jacket Overall Strength Member 900µm Tight Buffer Fiber Sub-Unit Central Strength Member COUNT SUB- UNITS (5) 14 (20) 225 (1000) 65 (290) (5) 16 (23) 225 (1000) 65 (290) (6) 18 (27) 225 (1000) 65 (290) (6) 20 (30) 245 (1090) 70 (310) (6) 23 (34) 320 (1425) 112 (500) (6) 24 (36) 320 (1425) 112 (500) (12) 76 (113) 600 (2670) 200 (890) (13) 84 (125) 800 (3560) 270 (1201) (17) 152 (226) 1000 (4448) 335 (1490) (16) 133 (197) 1000 (4448) 335 (1490) (17) 155 (231) 1200 (5338) 400 (1780) (19) 202 (301) 1500 (6672) 500 (2224) (23) 289 (430) 2000 (8896) 670 (2980) (25) 297 (442) 3000 (13345) 1000 (4448) (25) 304 (452) 3000 (13345) 1000 (4448) 24 Fiber DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (mm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300 nm 1310/1550 nm G300 Super/50 Super CG /1.0 BG /1.0 AP /1.0 18

26 Tight Buffer Distribution Plenum Cable Type OFNP, CSA FT-6 Premises Cables XX0021PNU XX0041PNU XX0061PNU XX0081PNU XX0121PNU XX0181P1U XX0241P1U XX0361P1D XX0481P1D XX0601P1D XX0721P1D XX0961P1D XX Denotes fiber type Flame-Retardant Jacket Overall Strength Member 900µm Tight Buffer Fiber Sub-Unit Central Strength Member COUNT SUB- UNITS Typical Cross-Section (4) 12 (17) 225 (1000) 65 (290) (5) 14 (20) 225 (1000) 65 (290) (5) 16 (24) 225 (1000) 65 (290) (5) 18 (27) 245 (1090) 70 (311) (6) 23 (34) 320 (1423) 112 (500) (13) 110 (164) 600 (2670) 200 (890) (14) 118 (175) 800 (3560) 270 (1201) (16) 151 (225) 1000 (4448) 335 (1490) (15) 135 (200) 1000 (4448) 335 (1490) (17) 186 (277) 1000 (4448) 335 (1490) (19) 217 (323) 1000 (4448) 335 (1490) (22) 312 (464) 1500 (6672) 500 (2224) 24 Fiber DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Product Construction: Fiber: 2-96 fibers 900µm tight buffer Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/glass rod (above 12 fibers) Overall Strength Member: Aramid fiber yarn Jacket: Flame-retardant polyvinyl chloride (PVC) or fluoropolymer Sequential footage markings* Orange Jacket Multimode fibers (except 10 Gbps) Aqua Jacket 10 Gbps Multimode fibers Yellow Jacket Singlemode fibers Features: Lightweight, flexible design simplifies installation Tight buffer provides individual fiber protection Tight buffered fibers are easy to handle and strip for field connectorization Sub-units are numbered for identification Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -20 C (-4 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 850 lbs/in (1485 N/cm) Maximum Vertical Rise 1,640 ft (500 m) Applications: Intrabuilding voice or data communication backbones UL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article (a) and (a) Compliances: UL and c(ul) Listed Type OFNP CSA FT-6 ANSI/TIA/EIA 568B.3 ICEA S ETL Verified GR-409 Accessories: BOKP breakout kits are suitable for Tight Buffer Distribution Plenum Cables *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (mm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300 nm 1310/1550 nm G300 Super/50 Super CG /1.0 BG /1.0 AP /1.0 OFNP 19

27 Premises Cables Tight Buffer Breakout Riser Cable Type OFNR, CSA FT-4 Product Construction: Fiber: 2-24 fibers 900µm tight buffer Color-coding per TTA/EIA 598B 2.4mm jacketed sub-units Central Strength Member: Aramid yarn Overall Strength Member: Aramid fiber yarn Jacket: Flame-retardant polyvinyl chloride (PVC) Sequential footage markings* Orange Jacket Multimode fibers (except 10 Gbps) Aqua Jacket 10 Gbps Multimode fibers Yellow Jacket Singlemode fibers Features: Rugged individual fiber protection Easily terminated with fiber sub-units Heavy-duty premises applications Sub-units are numbered for identification Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -20 C (-4 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 1000 lbs/in (1750 N/cm) Maximum Vertical Rise 1,640 ft (500 m) Applications: Intrabuilding voice or data communication backbones UL Listed Type OFNR for installation in vertical riser and general horizontal applications when installed in accordance with NEC article (b) and (b) Compliances: UL and c(ul) Listed Type OFNR CSA FT-4 ANSI/TIA/EIA 568B.3 ICEA S ETL Verified GR-409 XX0021B1R XX0041B1R XX0061B1R XX0081B1R XX0121B1R XX0181B1R XX0241B1R XX Denotes fiber type Typical Cross-Section 6 Fiber COUNT SUB- UNITS DIAMETER in (mm) (7) 28 (41) 270 (1200) 110 (490) (8) 37 (54) 450 (2000) 180 (800) (9) 51 (76) 450 (2000) 180 (800) (11) 71 (106) 600 (2670) 200 (890) (12) 79 (117) 790 (3515) 270 (1200) (14) 111 (165) 1000 (4450) 400 (1780) (16) 153 (228) 1230 (5470) 450 (2000) Flame-Retardant Jacket Overall Strength Member 900µm Tight Buffer Fiber 2.4mm Sub-Unit Central Strength Member WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (mm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300 nm 1310/1550 nm G300 Super/50 Super CG /1.0 BG /1.0 AP /1.0 20

28 Tight Buffer Breakout Plenum Cable Type OFNP, CSA FT-6 Premises Cables Product Construction: Fiber: 2-48 fibers 900µm tight buffer Color-coding per TIA/EIA 598B 2.4mm jacketed sub-units XX0021B1D XX0041B1D XX0061B1D XX0081B1D XX0121B1D XX0181B1D XX0241B1D XX0361B1D XX0481B1D XX Denotes fiber type Typical Cross-Section 6 Fiber COUNT SUB- UNITS DIAMETER in (mm) (6) 27 (40) 270 (1200) 110 (490) (7) 33 (49) 450 (2000) 180 (800) (9) 50 (74) 450 (2000) 180 (800) (10) 72 (107) 600 (2670) 200 (890) (11) 76 (113) 790 (3515) 270 (1200) (14) 122 (181) 1000 (4450) 400 (1780) (16) 171 (254) 1230 (5470) 450 (2000) (19) 209 (311) 2000 (8896) 600 (2669) (21) 261 (388) 2600 (11565) 780 (3470) Flame-Retardant Jacket Overall Strength Member 900µm Tight Buffer Fiber 2.4mm Sub-Unit Central Strength Member WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Central Strength Member: Epoxy/glass rod Overall Strength Member: Aramid fiber yarn Jacket: Flame-retardant fluoropolymer Sequential footage markings* Orange Jacket Multimode fibers (except 10 Gbps) Aqua Jacket 10 Gbps Multimode fibers Yellow Jacket Singlemode fibers Features: Rugged individual fiber protection Easily terminated with fiber sub-units Heavy-duty premises applications Sub-units are numbered for identification Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -20 C (-4 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 850 lbs/in (1485 N/cm) Maximum Vertical Rise 1,640 ft (500 m) Applications: Intrabuilding voice or data communication backbones ETL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article (a) and (a) Compliances: ETL and c(etl) Listed Type OFNP CSA FT-6 ANSI/TIA/EIA 568B.3 ICEA S ETL Verified *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (nm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300 nm 1310/1550 nm G300 Super/50 Super CG /1.0 BG /1.0 AP /1.0 21

29 Premises Cables Tight Buffer Distribution Low-Smoke, Zero-Halogen (LSZH) Cable Type OFNR, CSA FT-4 Product Construction: Fiber: 2-72 fibers 900µm tight buffer Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/glass rod (above 12 fibers) Overall Strength Member: Aramid fiber yarn Jacket: Flame-retardant polymer Sequential footage markings* Orange Jacket Multimode fibers (except 10 Gbps) Aqua Jacket 10 Gbps Multimode fibers Yellow Jacket Singlemode fibers Features: Lightweight, flexible design simplifies installation Tight buffer provides individual fiber protection Tight buffered fibers are easy to handle and strip for field connectorization Sub-units are numbered for identification Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -20 C (-4 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 850 lbs/in (1485 N/cm) Maximum Vertical Rise 1,640 ft (500 m) Applications: Intrabuilding voice or data communication backbones UL Listed Type OFNR for installation in vertical riser and general horizontal applications when installed in accordance with NEC article (b) and (b) Compliances: UL and c(ul) Listed Type OFNR CSA FT-4 ANSI/TIA/EIA 568B.3 ICEA S ETL Verified RoHS Compliant Directive 2002/95/EC Accessories: BOKP breakout kits are suitable for Tight Buffer Distribution (LSZH) Cables XX0021PNZ XX0041PNZ XX0061PNZ XX0081PNZ XX0121PNZ XX0181P1Z XX0241P1Z XX0361P1Z XX0481P1Z XX0601P1Z XX0721P1Z XX Denotes fiber type Typical Cross-Section Flame-Retardant Jacket Overall Strength Member 900µm Tight Buffer Fiber Sub-Unit Central Strength Member COUNT SUB- UNITS DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) (4) 11 (16) 225 (1000) 65 (290) (5) 13 (19) 225 (1000) 65 (290) (5) 15 (22) 225 (1000) 65 (290) (5) 17 (25) 245 (1090) 70 (310) (6) 21 (31) 320 (1425) 112 (500) (12) 84 (125) 600 (2670) 200 (890) (13) 92 (137) 800 (3560) 270 (1201) (16) 142 (211) 1000 (4448) 335 (1490) (15) 122 (182) 1000 (4448) 335 (1490) (17) 156 (232) 1200 (5338) 400 (1780) (19) 192 (286) 1500 (6672) 500 (2224) 24 Fiber *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (nm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300 nm 1310/1550 nm G300 Super/50 Super CG /1.0 BG /1.0 AP /1.0 22

30 Tight Buffer Distribution Interlock Armored Riser Cable Type OFCR, CSA FT-4 Premises Cables XX0021PNR-ILRA XX0041PNR-ILRA XX0061PNR-ILRA XX0121PNR-ILRA XX0241P1R-ILRA XX0361P1R-ILRA XX0481P1R-ILRA XX0601P1R-ILRA XX0721P1R-ILRA XX0961P1R-ILRA XX1201P1R-ILRA XX1441P1R-ILRA XX Denotes fiber type COUNT Typical Cross-Section 6 Fiber SUB- UNITS DIAMETER in (mm) (13.3) 104 (154) 550 (2447) 165 (734) (13.3) 104 (154) 550 (2447) 165 (734) (13.6) 116 (173) 550 (2447) 165 (734) (15.7) 159 (237) 550 (2447) 165 (734) (22.6) 265 (394) 1000 (4448) 300 (1334) (24.9) 360 (536) 1000 (4448) 300 (1334) (25.4) 365 (543) 1000 (4448) 300 (1334) (25.5) 385 (573) 1000 (4448) 300 (1334) (27.4) 460 (684) 1000 (4448) 300 (1334) (30.8) 590 (878) 1000 (4448) 300 (1334) (34.8) 635 (945) 1000 (4448) 300 (1334) (34.8) 640 (952) 1000 (4448) 300 (1334) Outer Flame- Retardant Jacket Interlock Armor Sub-Unit Flame- Retardant Jacket Overall Strength Member 900µm Tight Buffer Fiber WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Product Construction: Fiber: fibers 900µm tight buffer Color-coding per TIA/EIA 598B Overall Strength Member: Aramid fiber yarn Inner Jacket: Flame-retardant compound Armor: Interlock aluminum (-ILRA) Option: Interlock galavanized steel (-ILR) Outer Jacket: Flame-retardant compound Sequential footage markings* Orange Jacket Multimode fibers (except 10 Gbps) Aqua Jacket 10 Gbps Multimode fibers Yellow Jacket Singlemode fibers Features: Interlock armor provides outstanding mechanical protection Interlock armor is flexible and easy to use Tight buffer provides individual fiber protection Sub-units are numbered for identification Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -20 C (-4 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 1,500 lbs/in (2,627 N/cm) Applications: Harsh premises environments requiring heavyduty protection Type OFCR for installation in any premises location when installed in accordance with NEC article (b) and (b) Compliances: Listed Type OFCR CSA FT-4 Accessories: BOKP breakout kits are suitable for Tight Buffer Distribution Interlock Armored Riser Cables Note: Armored cable without an outer jacket available upon request (-IL) *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (mm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300 nm 1310/1550 nm G300 Super/50 Super CG /1.0 BG /1.0 AP /1.0 23

31 Premises Cables Tight Buffer Distribution Interlock Armored Plenum Cable Type OFCP, CSA FT-6 Product Construction: Fiber: 4-96 fibers 900µm tight buffer Color-coding per TIA/EIA 598B Overall Strength Member: Aramid fiber yarn Inner Jacket: Flame-retardant material Armor: Interlock aluminum (-ILPA) Option: Interlock galvanized steel Outer Jacket: Flame-retardant fluoropolymer Sequential footage markings* Orange Jacket Multimode fibers (except 10 Gbps) Aqua Jacket 10 Gbps Multimode fibers Yellow Jacket Singlemode fibers Features: Interlock armor provides outstanding mechanical protection Interlock armor is flexible and easy to use Tight buffer provides individual fiber protection Sub-units are numbered for identification Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -20 C (-4 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 1,500 lbs/in (2,627 N/cm) Applications: Harsh premises environments requiring heavyduty protection ETL Type OFCP for installation in any premises location when installed in accordance with NEC article (a) and (a) Compliances: ETL Listed Type OFCP CSA FT-6 Accessories: BOKP breakout kits are suitable for Tight Buffer Distribution Interlock Armored Plenum Cables Note: Armored cable without an outer jacket available upon request (-IL) *Sequential meter markings available upon request XX0041PNU-ILPA XX0061PNU-ILPA XX0121PNU-ILPA XX0241PNU-ILPA XX0361PNU-ILPA XX0481PNU-ILPA XX0601P1D-ILPA XX0721P1D-ILPA XX0961P1D-ILPA XX Denotes fiber type COUNT Typical Cross-Section 6 Fiber SUB- UNITS DIAMETER in (mm) (12.2) 100 (149) 550 (2447) 165 (734) (12.2) 103 (153) 550 (2447) 165 (734) (14.9) 120 (179) 550 (2447) 165 (734) (18.7) 169 (252) 1000 (4448) 300 (1334) (19.1) 186 (277) 1000 (4448) 300 (1334) (20.3) 211 (314) 1000 (4448) 300 (1334) (25.91) 450 (670) 1000 (4448) 300 (1334) (27.68) 508 (756) 1000 (4448) 300 (1334) (31.11) 609 (906) 1000 (4448) 335 (1490) Outer Flame- Retardant Jacket Interlock Armor Sub-Unit Flame- Retardant Jacket Overall Strength Member 900µm Tight Buffer Fiber WEIGHT lbs/1000' (kg/km) A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) TYPICAL TYPES DIMENSIONS (mm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300 nm 1310/1550 nm G300 Super/50 Super CG /1.0 BG /1.0 AP /1.0 24

32 NextGen Brand Indoor/Outdoor Cables Index Page Central Tube Single Jacket Plenum Cable 26 Loose Tube Single Jacket Plenum Cable 27 Tight Buffer Distribution Riser Cable 28 Tight Buffer Distribution Plenum Cable 29 The concept, production and application of indoor/outdoor fiber optic cables has been a big part of the NextGen Brand product line for more than a decade. As a leader in easy-to-use, field-friendly fiber optic cables, the indoor/outdoor product line has been especially well-known to users who appreciate the features it provides. Applications: Whether primarily for indoor or outdoor use, we have an impressive choice of products that have the ability to route from either a plenum or riser building space to an outdoor run. This eliminates the costly and spaceconsuming transition point at the building entrance and improves the system loss budget. These cables are most efficient when used to directly connect equipment rooms (on any floor) in different buildings or to connect a manhole location to an equipment room. Range of Products: Indoor/outdoor fiber optic cables include loose tube (gelfilled) and tight buffer (900µm) designs. These are available in a variety of configurations and jacket types to cover riser and plenum requirements for indoor cable and the ability to be run in duct, direct buried or aerial/lashed in the outside plant. The following catalog pages provide information on proper interbuilding and intrabuilding applications. Features: These products reduce the system cost by eliminating splice points, simplifying cable handling and gaining flexibility with the choice of building entrances. All cables meet appropriate NEC requirements and are listed with ETL or UL. Tight buffer designs allow direct termination of fibers with industry-standard connectors and techniques. Loose tube designs provide more fiber protection in harsh outdoor environments and are readily Central Tube Single Jacket Riser Cable 30 Loose Tube Single Jacket Riser Cable 31 Loose Tube Dual Jacket Riser Cable Chemical- Resistant 32 Loose Tube Single Jacket Low-Smoke, Zero-Halogen (LSZH) Cable 33 Loose Tube Dual Jacket Armored Low-Smoke, Zero- Halogen (LSZH) Cable 34 spliced to existing outside plant cables. Most indoor/outdoor fiber optic cables utilize Dry Water Block technology in the cable core to protect the fibers and provide fast, clean fiber preparation. As with all NextGen fiber optic cables, splitter kits are available to reinforce and assist in preparing the fibers for termination. 25

33 Indoor/Outdoor Cables Central Tube Single Jacket Plenum Cable Type OFNP, CSA FT-6 Product Construction: Fiber: 2-12 fibers Dry central tube with Super Absorbent Polymer Color-coding per TIA/EIA 598B Overall Strength Member: Aramid fiber yarn or fiberglass Jacket: Black UV-, moisture-resistant and flameretardant materials Sequential footage markings* COUNT LOOSE TUBES DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Option: Interlock steel or aluminum (-ILP or -ILPA) Features: Simple, flexible design allows for easier installations Plenum-rated for indoor applications UV- and moisture-resistant for outdoor applications Dry loose tube for ease of termination Dry Water Block cable core for ease of handling Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -20 C (-4 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 150 lbs/in (263 N/cm) Maximum Vertical Rise 1,200 ft (366 m) Applications: Intrabuilding voice or data communication backbones Installed in ducts, underground conduits or aerial/lashed Type OFNP for installation in plenum airways and horizontal applications when installed in accordance with NEC article (a) and (a) XX0024UNU XX0044UNU XX0064UNU XX0084UNU XX0124UNU XX Denotes fiber type Typical Cross-Section 6 Fiber (6.6) 35 (51) 300 (1334) 100 (445) (6.6) 35 (51) 300 (1334) 100 (445) (6.6) 35 (51) 300 (1334) 100 (445) (6.6) 35 (51) 300 (1334) 100 (445) (6.6) 35 (51) 300 (1334) 100 (445) Flame-Retardant Jacket Overall Strength Member (Dry Water Block) Central Tube Fiber Compliances: ETL Listed Type OFNP CSA FT-6 ICEA S Accessories: SPK splitter kits are suitable for Central Tube Single Jacket Plenum Cables *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm G300 Super/50 Super CG /1.0 - BG /1.0 - AP /0.4 26

34 Loose Tube Single Jacket Plenum Cable Type OFNP, CSA FT-6 Indoor/Outdoor Cables Product Construction: Fiber: fibers Dry loose tube with Super Absorbent Polymer Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/glass rod XX0023M1D-DT XX0044M1D-DT XX0064M1D-DT XX0084M1D-DT XX0124M1D-DT XX0184M1D-DT XX0244M1D-DT XX0364M1D-DT XX0484M1D-DT XX0604M1D-DT XX0724M1D-DT XX0964M1D-DT XX1444H1D-DT* XX Denotes fiber type * Double Jacket Design Typical Cross-Section 36 Fiber COUNT LOOSE TUBES (8) 46 (69) 300 (1334) 100 (445) (8) 47 (70) 300 (1334) 100 (445) (8) 48 (71) 300 (1334) 100 (445) (8) 46 (69) 300 (1334) 100 (445) (8) 47 (69) 300 (1334) 100 (445) (8) 45 (67) 300 (1334) 100 (445) (8) 44 (65) 300 (1334) 100 (445) (9) 50 (75) 300 (1334) 100 (445) (10) 57 (85) 300 (1334) 100 (445) (10) 54 (80) 300 (1334) 100 (445) (10) 65 (97) 300 (1334) 100 (445) (12) 98 (146) 300 (1334) 100 (445) (18) 179 (266) 300 (1334) 100 (445) Flame-Retardant Jacket Overall Strength Member Loose Tube Fiber DIAMETER in (mm) Central Strength Member Dry Water Block Material WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Overall Strength Member: Aramid fiber yarn or fiberglass Jacket: Black UV-, moisture-resistant and flameretardant materials Sequential footage markings* Option: Interlock steel or aluminum (-ILP or -ILPA) Features: Loose tube plenum design provides maximum cable route flexibility Dry loose tube for ease of termination Enhanced temperature performance Excellent chemical-resistant cable for harsh industrial environments Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -20 C (-4 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 150 lbs/in (263 N/cm) Applications: Interbuilding and intrabuilding voice or data communication backbones Install in ducts, underground conduits or aerial/lashed ETL Listed Type OFNP for installation in plenum airways and horizontal applications when installed in accordance with NEC article (a) and (a) Compliances: ETL and c(etl) Listed Type OFNP CSA FT-6 ICEA S Accessories: SPK splitter kits are suitable for Loose Tube Single Jacket Plenum Cables *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm G300 Super/50 Super CG /1.0 - BG /1.0 - AP /0.4 27

35 Indoor/Outdoor Cables Tight Buffer Distribution Riser Cable Type OFNR, CSA FT-4 Product Construction: Fiber: fibers 900µm tight buffer Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/glass rod (above 12 fibers) Overall Strength Member: Aramid fiber yarn Jacket: Flame-retardant polyvinyl chloride (PVC) Sequential footage markings* Orange Jacket Multimode fibers (except 10 Gb/s) Aqua Jacket 10 Gb/s Multimode fibers Yellow Jacket Singlemode fibers Option: Interlock steel or aluminum (-ILR or -ILRA) Features: Dry Water Block cable core for fiber protection Improved temperature performance Direct termination of connectors on tight buffer Sub-units are numbered for identification Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 850 lbs/in (1485 N/cm) Maximum Vertical Rise 1,640 ft (500 m) Applications: Intrabuilding and interbuilding voice or data communication backbones Outdoor use in ducts and underground conduits UL Listed Type OFNR for installation in vertical riser and general horizontal applications when installed in accordance with NEC article (b) and (b) Compliances: UL and c(ul) Listed Type OFNR CSA FT-4 ICEA S Accessories: BOKP breakout kits are suitable for Tight Buffer Distribution Riser Cables XX0021ANR XX0041ANR XX0061ANR XX0081ANR XX0101ANR XX0121ANR XX0181A1R XX0241A1R XX0361A1R XX0481A1R XX0601A1R XX0721A1R XX0961A1R XX1201A1R XX1441A1R XX Denotes fiber type Typical Cross-Section Flame-Retardant Jacket Overall Strength Member 900µm Tight Buffer Fiber Sub-Unit Dry Water Block Material COUNT SUB- UNITS DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) (5) 14 (20) 300 (1334) 90 (400) (5) 16 (24) 320 (1423) 96 (427) (6) 18 (27) 320 (1423) 96 (427) (6) 20 (30) 320 (1423) 96 (427) (6) 23 (34) 400 (1780) 120 (534) (6) 24 (36) 400 (1780) 120 (534) (12) 79 (118) 750 (3336) 250 (1112) (13) 86 (128) 1000 (4448) 300 (1334) (17) 147 (219) 1300 (5783) 390 (1735) (16) 137 (204) 1300 (5783) 390 (1735) (18) 168 (250) 1500 (6672) 450 (2002) (20) 207 (308) 1900 (8452) 570 (2535) (23) 289 (430) 2000 (8896) 670 (2980) (26) 313 (466) 3000 (13345) 1000 (4448) (26) 314 (467) 3000 (13345) 1000 (4448) 24 Fiber *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm G300 Super/50 Super CG /1.0 - BG /1.0 - AP /1.0 28

36 Tight Buffer Distribution Plenum Cable Indoor/Outdoor Dry Water Block, Type OFNP, CSA FT-6 Indoor/Outdoor Cables Product Construction: Fiber: 2-96 fibers 900µm tight buffer Color-coding per TIA/IEIA 598B Central Strength Member: Epoxy/glass rod (above 12 fibers) XX0021ANU XX0041ANU XX0061ANU XX0081ANU XX0101ANU XX0121ANU XX0181A1U XX0241A1U XX0361A1D XX0481A1D XX0601A1D XX0721A1D XX0961A1D XX Denotes fiber type * Double Jacket Design COUNT SUB- UNITS Typical Cross-Section Flame-Retardant Jacket Overall Strength Member 900µm Tight Buffer Fiber Sub-Unit Central Strength Member DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) (4.3) 11.7 (17.4) 300 (1334) 90 (400) (4.6) 13.7 (20.4) 320 (1423) 96 (427) (4.9) 16.0 (23.8) 320 (1423) 96 (427) (5.2) 18.0 (26.8) 320 (1423) 96 (427) (5.6) 20.7 (30.8) 400 (1780) 120 (534) (5.8) 22.7 (33.8) 400 (1780) 120 (534) (12.6) 110 (164) 750 (3336) 250 (1112) (13.7) 118 (176) 1000 (4448) 300 (1334) (15.5) 151 (225) 1300 (5783) 390 (1735) (14.8) 135 (200) 1300 (5783) 390 (1735) (17.0) 186 (277) 1500 (6672) 450 (2002) (18.5) 217 (323) 1900 (8452) 570 (2535) (21.8) 312 (464) 2000 (8896) 670 (2980) 24 Fiber Overall Strength Member: Aramid yarn Jacket: Flame-retardant polymer Sequential footage markings* Orange Jacket - Multimode fibers (except 10Gb/s) Aqua Jacket - 10Gb/s Multimode fibers. Yellow Jacket - Singlemode fibers Option: Interlock steel or aluminum (-ILP or -ILPA) Features: Dry Water Block cable core for fiber protection. Improved temperature performance Direct termination of connectors on tight buffer. Sub-units are numbered for identification Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 850 lbs/in (1485 N/cm) Maximum Vertical Rise - 1,640 ft (500 m) Applications: Intrabuilding and interbuilding voice or data communication backbones Outdoor use in ducts and underground conduits UL Listed Type OFNP for installation in vertical riser and general horizontal applications when installed in accordance with NEC article (a) and (a) Compliances: UL and c(ul) Listed Type OFNP CSA FT-6 ICEA S Accessories: BOKP breakout kits are suitable for Tight Buffer Distribution Plenum Cables A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm G300 Super/50 Super *Sequential meter markings available upon request CG /1.0 - BG /1.0 - AP /0.4 NOTE: Additional fiber types available. Reference the Fiber Specifications and Fiber Selection Guide on page XX OFNP 29

37 Indoor/Outdoor Cables Central Tube Single Jacket Riser Cable Type OFNR, CSA FT-4 Product Construction: Fiber: 2-12 fibers Dry central tube with Super Absorbent Polymer Color-coding per TIA/EIA 598B Overall Strength Member: Aramid fiber yarn or fiberglass Jacket: Black UV-, moisture-resistant and flameretardant materials Sequential footage markings* COUNT LOOSE TUBES DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Option: Interlock Steel or Aluminum (-ILR or -ILRA) Features: Simple, flexible design allows for easier installations Riser-rated for indoor applications UV- and moisture-resistant for outdoor applications Dry loose tube for ease of termination Dry Water Block cable core for ease of handling Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -20 C (-4 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 150 lbs/in (263 N/cm) Maximum Vertical Rise 1,200 ft (366 m) Applications: Intrabuilding voice or data communication backbones Installed in ducts, underground conduits or aerial/lashed ETL Listed Type OFNR for installation in vertical riser and general horizontal applications when installed in accordance with NEC article (b) and (b) Compliances: ETL and c(etl) Listed Type OFNR CSA FT-4 ICEA S Accessories: SPK splitter kits are suitable for Central Tube Single Jacket Riser Cables XX0024UNM-DT XX0044UNM-DT XX0064UNM-DT XX0084UNM-DT XX0124UNM-DT XX Denotes fiber type Typical Cross-Section 6 Fiber (6.9) 35 (52) 300 (1334) 100 (445) (6.9) 35 (52) 300 (1334) 100 (445) (6.9) 35 (52) 300 (1334) 100 (445) (6.9) 35 (52) 300 (1334) 100 (445) (6.9) 35 (52) 300 (1334) 100 (445) Flame-Retardant Jacket Overall Strength Member (Dry Water Block) Central Tube Fiber *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm G300 Super/50 Super CG /1.0 - BG /1.0 - AP /0.4 30

38 Loose Tube Single Jacket Riser Cable Type OFNR, CSA FT-4 Indoor/Outdoor Cables Product Construction: Fiber: fibers Dry loose tube with Super Absorbent Polymer Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/glass rod XX0023M1M-DT XX0044M1M-DT XX0064M1M-DT XX0084M1M-DT XX0124M1M-DT XX0184M1M-DT XX0244M1M-DT XX0364M1M-DT XX0484M1M-DT XX0604M1M-DT XX0724M1M-DT XX0964M1M-DT XX1444M1M-DT XX Denotes fiber type Typical Cross-Section 36 Fiber COUNT LOOSE TUBES DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) (9) 52 (78) 600 (2670) 200 (890) (9) 53 (79) 600 (2670) 200 (890) (9) 53 (80) 600 (2670) 200 (890) (9) 52 (78) 600 (2670) 200 (890) (9) 52 (78) 600 (2670) 200 (890) (9) 52 (77) 600 (2670) 200 (890) (9) 51 (76) 600 (2670) 200 (890) (10) 58 (86) 600 (2670) 200 (890) (11) 64 (96) 600 (2670) 200 (890) (11) 62 (92) 600 (2670) 200 (890) (12) 75 (112) 600 (2670) 200 (890) (14) 109 (162) 600 (2670) 200 (890) (17) 169 (251) 600 (2670) 200 (890) Flame-Retardant Jacket Overall Strength Member Loose Tube Fiber Central Strength Member Dry Water Block Material MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Overall Strength Member: Aramid fiber yarn Jacket: Black UV-, moisture-resistant and flameretardant polymer material Sequential footage markings* Option: Interlock steel or aluminum (-ILR or -ILRA) Features: Dry Water Block cable core for ease of handling Dry loose tube for ease of termination Riser rated for indoor applications Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 150 lbs/in (263 N/cm) Maximum Vertical Rise 1,640 ft (500 m) Applications: Interbuilding and intrabuilding voice or data communication backbones Installed in ducts, underground conduits or aerial/lashed ETL Listed Type OFNR for installation in vertical riser and general horizontal applications when installed in accordance with NEC article (b) and (b) Compliances: ETL and c(etl) Listed Type OFNR CSA FT-4 ICEA S Accessories: SPK splitter kits are suitable for Loose Tube Single Jacket Riser Cables *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm G300 Super/50 Super CG /1.0 - BG /1.0 - AP /0.4 31

39 Indoor/Outdoor Cables Loose Tube Dual Jacket Riser Cable Chemical-Resistant Type OFNR, CSA FT-4 Product Construction: Fiber: fibers Dry loose tube with Super Absorbent Polymer Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/glass rod Overall Strength Member: Aramid fiber yarn or fiberglass Inner Jacket: Orange UV-, moisture-resistant and flameretardant material Outer Jacket: Black UV-, moisture-resistant and flameretardant material Sequential footage markings* Option: Interlock steel or aluminum (-ILR or -ILRA) Features: Excellent chemical resistance Dual-jacketed for harsh environments Riser-rated for indoor applications UV- and moisture-resistant for outdoor applications Dry water block cable core for ease of handling Dry loose tube for ease of termination Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 500 lbs/in (875 N/cm) Maximum Vertical Rise 1,640 ft (500 m) Applications: Interbuilding and intrabuilding voice or data communication backbones Installed in ducts, aerial/lashed or direct burial UL Listed Type OFNR for installation in vertical riser and general horizontal applications when installed in accordance with NEC article (b) and (b) Compliances: UL and c(ul) Listed Type OFNR CSA FT-4 ICEA S Accessories: SPK splitter kits are suitable for Loose Tube Dual Jacket Riser Cables *Sequential meter markings available upon request XX0023H1M-DT XX0044H1M-DT XX0064H1M-DT XX0084H1M-DT XX0124H1M-DT XX0184H1M-DT XX0244H1M-DT XX0364H1M-DT XX0484H1M-DT XX0604H1M-DT XX0724H1M-DT XX0964H1M-DT XX1204H1M-DT XX1444H1M-DT XX1924H1M-DT XX2164H1M-DT XX Denotes fiber type Typical Cross-Section 36 Fiber COUNT LOOSE TUBES (11) 75 (112) 600 (2670) 200 (890) (11) 75 (112) 600 (2670) 200 (890) (11) 75 (112) 600 (2670) 200 (890) (11) 75 (112) 600 (2670) 200 (890) (11) 75 (112) 600 (2670) 200 (890) (11) 75 (112) 600 (2670) 200 (890) (11) 75 (112) 600 (2670) 200 (890) (11) 84 (125) 600 (2670) 200 (890) (12) 96 (142) 600 (2670) 200 (890) (12) 94 (139) 600 (2670) 200 (890) (13) 109 (162) 600 (2670) 200 (890) (15) 144 (214) 600 (2670) 200 (890) (17) 171 (255) 600 (2670) 200 (890) (18) 210 (312) 600 (2670) 200 (890) (19) 217 (323) 600 (2670) 200 (890) (19) 210 (313) 600 (2670) 200 (890) Outer Flame- Retardant Jacket Overall Strength Member Inner Flame- Retardant Jacket Loose Tube Fiber DIAMETER in (mm) Central Strength Member WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm G300 Super/50 Super CG /1.0 - BG /1.0 - AP /0.4 32

40 Indoor/Outdoor Cables Loose Tube Single Jacket Low-Smoke, Zero-Halogen (LSZH) Cable Type OFN/LS Product Construction: Fiber: fibers Loose tube gel-filled Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/glass rod XX0023M1Z XX0044M1Z XX0064M1Z XX0084M1Z XX0124M1Z XX0184M1Z XX0244M1Z XX0364M1Z XX0484M1Z XX0604M1Z XX0724M1Z XX0964M1Z XX1204M1Z XX1444M1Z XX Denotes fiber type COUNT LOOSE TUBES Typical Cross-Section (9) 59 (89) 600 (2670) 200 (890) (9) 59 (89) 600 (2670) 200 (890) (9) 59 (89) 600 (2670) 200 (890) (9) 59 (89) 600 (2670) 200 (890) (9) 60 (89) 600 (2670) 200 (890) (9) 60 (89) 600 (2670) 200 (890) (9) 61 (90) 600 (2670) 200 (890) (10) 66 (98) 600 (2670) 200 (890) (10) 74 (110) 600 (2670) 200 (890) (10) 74 (110) 600 (2670) 200 (890) (11) 83 (123) 600 (2670) 200 (890) (13) 100 (148) 600 (2670) 200 (890) (15) 127 (189) 600 (2670) 200 (890) (16) 151 (225) 600 (2670) 200 (890) Flame-Retardant Jacket Overall Strength Member Loose Tube Fiber DIAMETER in (mm) Central Strength Member WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Overall Strength Member: Aramid fiber yarn Jacket: Black UV-, moisture-resistant and flameretardant polymer Sequential footage markings* Features: Dry Water Block cable core for ease of handling Loose tube gel-filled for maximum fiber protection LSZH jacket for fire protection Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -40 C (-40 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 150 lbs/in (263 N/cm) Maximum Vertical Rise 1,640 ft (500 m) Applications: Interbuilding and intrabuilding voice or data communication backbones Installed in ducts, underground conduits or aerial/lashed UL Listed Type OFN/LS for installation in cable trays and general horizontal applications when installed in accordance with NEC article (d) and (c) Compliances: UL and c(ul) Listed Type OFN/LS IEEE-383 ICEA S Accessories: SPK splitter kits are suitable for Loose Tube Single Jacket (LSZH) cables 36 Fiber Dry Water Block Material *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm G300 Super/50 Super CG /1.0 - BG /1.0 - AP /0.4 33

41 Indoor/Outdoor Cables Loose Tube Dual Jacket Armored Low-Smoke, Zero-Halogen (LSZH) Cable Product Construction: Fiber: fibers Loose tube gel-filled Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/glass rod Overall Strength Member: Aramid fiber yarn or fiberglass Inner Jacket: Black - LSZH polymer Armor: 0.006" corrugated coated steel tape Outer Jacket: Black - LSZH Polymer Sequential footage markings* Features: Loose tube gel-filled construction for superior fiber protection UV- and moisture-resistant design Rodent-proof construction Dry water block cable core for ease of handling Performance: Temperature: Storage -40 C (-40 F) to +80 C (+176 F) Operating -40 C (-40 F) to +80 C (+176 F) Installation -20 C (-4 F) to +80 C (+176 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 500 lbs/in (876 N/cm) Applications: Interbuilding voice or data communication backbones Installed in ducts, underground conduits, aerial/lashed or direct buried Rapid Transit Systems Compliances: ANSI/TIA/EIA 568B.3 ICEA S Meets GR-20 Accessories: SPK splitter kits are suitable for Loose Tube Dual Jacket Armored LSZH Cables *Sequential meter markings available upon request XX0023H1L XX0044H1L XX0064H1L XX0084H1L XX0124H1L XX0184H1L XX0244H1L XX0364H1L XX0484H1L XX0604H1L XX0724H1L XX0964H1L XX1204H1L XX1444H1L XX Denotes fiber type COUNT LOOSE TUBES FILLERS Typical Cross-Section 36 Fiber (15) 120 (194) 600 (2670) 200 (890) (15) 120 (194) 600 (2670) 200 (890) (15) 120 (194) 600 (2670) 200 (890) (15) 120 (194) 600 (2670) 200 (890) (15) 120 (194) 600 (2670) 200 (890) (15) 120 (194) 600 (2670) 200 (890) (15) 120 (194) 600 (2670) 200 (890) (16) 181 (269) 600 (2670) 200 (890) (17) 190 (283) 600 (2670) 200 (890) (17) 192 (286) 600 (2670) 200 (890) (17) 197 (293) 600 (2670) 200 (890) (18) 240 (357) 600 (2670) 200 (890) (19) 255 (379) 600 (2670) 200 (890) (21) 270 (402) 600 (2670) 200 (890) Outer Jacket - LSZH Armor DIAMETER in Moisture Barrier Outer Strength Member (6) 6 Fiber, Loose Tube Component Inner Jacket - LSZH Inner Strength Member (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN. BANDWIDTH (Mhz km) MAX. ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm Premium G300 AQ /0.3 CG /1.0 34

42 NextGen Brand Interconnect Cables Index Page Interconnect cables are used in a variety of Fiber-To-The-Desk (FTTD) and network connection schemes. These cables are constructed to easily terminate with industry-standard connectors such as the SC and ST. To serve the new market evolution into highdensity cabling and terminations, we offer an extended cable product line that is compatible with all of the new connection systems, such as MT-RJ, MTP, LC and other Small Form Factor (SFF) components. Applications: Interconnect cables are generally one- or two-fiber cable constructions for use in horizontal runs (Fiber-To-The-Desk), as patchcords in communication closets and for OEM assemblies. These cables are constructed to easily terminate with industry-standard connectors such as the SC and the ST, as well as the new generation of Small Form Factor (SFF) connector designs. Range of Products: Low fiber count ( 12) cables with riser (OFNR) or plenum (OFNP) listings comprise this family of cables. Most designs are tight buffered while some are available with fiber ribbons. These fiber ribbons allow fast termination to MTP and MT-RJ connectors or they may be fusion spliced to other cables. Features: The interconnect cables are constructed to have the proper geometry to mate with industry-standard terminations. Generally, no breakout or splitter kits are required. The cables are very small and flexible so that they may be incorporated into highdensity cable management systems. Some cables are available with Quik-Strip technology for easy removal of the 900µm layer. 3.0mm Simplex/Duplex Riser and Plenum Cable mm Simplex/Duplex Riser Cable 37 Ribbon Distribution Riser and Plenum Cable 38 35

43 Interconnect Cables 3.0mm Simplex/Duplex Riser and Plenum Cable Type OFNR, CSA FT-4 and Type OFNP, CSA FT-6 Product Construction: Fiber: 1 or 2 fibers 900µm tight buffer Overall Strength Member: Aramid fiber yarn Jacket: 3.0mm unit diameters Flame-retardant polyvinyl chloride (PVC) Sequential footage markings* Orange Jacket Multimode fibers (except 10 Gbps) Aqua Jacket 10 Gbps Multimode fibers Yellow Jacket Singlemode fibers Features: Industry-standard design Ideal for interconnect and Fiber-To-The-Desk (FTTD) Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -20 C (-4 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 500 lbs/in (875 N/cm) Applications: Interconnect design compatible with connectors requiring 3.0mm jacket diameter Fiber-To-The-Desk (FTTD) UL Listed Type OFNR for installation in vertical riser and general horizontal applications when installed in accordance with NEC article (b) and (b) UL Listed Type OFNP for installation in ducts, plenums and other spaces used as environmental air returns when installed in accordance with NEC article (a) and (a) Compliances: UL and c(ul) Listed Type OFNR/OFNP CSA FT-4, CSA FT-6 GR-409 *Sequential meter markings available upon request Riser XX0011SNR3.0 XX0021ZNR3.0 Plenum XX0011SNU3.0 XX0021ZNU3.0 xx Denotes fiber type COUNT Typical Cross-Section (3.0) 5.5 (8.2) 110 (490) 65 (290) x (2.9 x 6.0) 10.5 (15.6) 220 (980) 160 (580) (3.0) 6.5 (9.7) 110 (490) 65 (290) x (2.9 x 6.0) 12.1 (18.0) 220 (980) 160 (580) Simplex SUB- UNITS DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) Flame-Retardant Jacket Overall Strength Member 900µm Tight Buffer Fiber Flame-Retardant Jacket Overall Strength Member 900µm Tight Buffer Fiber MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Duplex A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN BANDWIDTH (Mhz km) MAX ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm G300 Super/50 Super CG /1.0 BG /1.0 AP /1.0 OFNP 36

44 1.6mm Simplex/Duplex Riser Cable Type OFNR, CSA FT-4 Interconnect Cables Product Construction: Fiber: 1 or 2 fibers 900µm tight buffer Overall Strength Member: Aramid fiber yarn XX0011SNR1.6 XX0021ZNR1.6 xx Denotes fiber type COUNT Typical Cross-Section (1.6) 1.7 (2.5) 25 (111) 7.5 (33) x0.136 (1.6x3.5) 3.5 (5.2) 50 (222) 15 (67) Simplex SUB- UNITS DIAMETER in (mm) Flame-Retardant Jacket Overall Strength Member 900µm Tight Buffer Fiber WEIGHT lbs/1000' (kg/km) Flame-Retardant Jacket Overall Strength Member 900µm Tight Buffer Fiber MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Jacket: 1.6mm unit diameters Flame-retardant polyvinyl chloride (PVC) Sequential footage markings* Orange Jacket Multimode fibers (except 10 Gbps) Aqua Jacket 10 Gbps Multimode fibers Yellow Jacket Singlemode fibers Features: Compatible with LC connectors Ideal for interconnect and Fiber-To-The-Desk (FTTD) Performance: Temperature: Storage -40 C (-40 F) to +70 C (+158 F) Operating -20 C (-4 F) to +70 C (+158 F) Minimum Bend Radius: 20 X OD Installation 10 X OD In-Service Maximum Crush Resistance: 150 lbs/in (263 N/cm) Applications: Interconnect design compatible with LC and other connectors requiring 1.6mm jacket diameter Fiber-To-The-Desk (FTTD) UL Listed Type OFNR for installation in vertical riser and general horizontal applications when installed in accordance with NEC article (b) and (b) Compliances: ETL Listed Type OFNR CSA FT-4 *Sequential meter markings available upon request Duplex A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN BANDWIDTH (Mhz km) MAX ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm G300 Super/50 Super CG /1.0 BG /1.0 AP /1.0 37

45 Interconnect Cables Ribbon Distribution Riser and Plenum Cable Type OFNR/OFNP, CSA FT-4, FT-6 Product Construction: Fiber: 2-12 fibers 250µm fiber ribbons Overall Strength Member: Aramid fiber yarn Jacket: Flame-retardant PVC Sequential footage markings* Orange Jacket Multimode fibers (except 10 Gbps) Aqua Jacket 10 Gbps Multimode fibers Yellow Jacket Singlemode fibers Features: Small, flexible design for routing in patch panels, closures, etc. Ribbon fiber for mass fusion splicing Performance: Temperature: Storage -40 C (-40 F) to +65 C (+149 F) Operating -20 C (-4 F) to +50 C (+122 F) Minimum Bend Radius: 2.6 (6.5cm) Installation 1.6 (4.0cm) In-Service Maximum Crush Resistance: 57 lbs/in (100 N/cm) Applications: Interconnect design compatible with MTP connectors Fiber-To-The-Desk (FTTD) UL Listed Type OFNR for installation in vertical riser and general horizontal applications when installed in accordance with NEC article (b) and (b) UL Listed Type OFNP for installation in plenum airways and horizontal applications when installed in accordance with NEC article (a) and (a) Pre-assembled optical hardware Compliances: UL and c(ul) Listed Type OFNR/OFNP CSA FT-4, FT-6 XX0026RNR XX0046RNR XX0066RNR XX0086RNR XX0126RNR XX0026RNP XX0046RNP XX0066RNP XX0086RNP XX0126RNP xx Denotes fiber type COUNT Typical Cross-Section DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) (2.3) 4.0 (6) 50 (220) 25 (110) x.090 (2.0 x 2.3) 4.7 (7) 50 (220) 25 (110) x.130 (2.4 x 3.3) 5.4 (8) 50 (220) 25 (110) x.130 (2.4 x 3.3) 6.1 (9) 50 (220) 25 (110) x.194 (2.4 x 4.9) 8.0 (12) 50 (220) 25 (110) (2.3) 4.0 (6) 50 (220) 25 (110) x.090 (2.0 x 2.3) 4.7 (7) 50 (220) 25 (110) x.130 (2.4 x 3.3) 5.4 (8) 50 (220) 25 (110) x.130 (2.4 x 3.3) 6.1 (9) 50 (220) 25 (110) x.194 (2.4 x 4.9) 8.0 (12) 50 (220) 25 (110) Flame-Retardant Jacket Overall Strength Member Fiber Ribbon MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) *Sequential meter markings available upon request A complete listing of NextGen Brand fiber types are specified on page 2 of this catalog. Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available. TYPICAL TYPES DIMENSIONS (µm) MIN BANDWIDTH (Mhz km) MAX ATTENUATION (db/km) DESCRIPTION TYPE CORE CLAD COATING 850nm 1300nm 850/1300nm 1310/1550nm G300 Super/50 Super CG BG AP / / /1.0 NOTE: Other higher counts available upon request. OFNP 38

46 Specialty and Tactical Cable Brand Rex Brand Specialty Cable Brand Rex Brand fiber optic specialty cables are designed, engineered and manufactured to specification for specialized and custom applications for an extensive range of markets in military, marine/oil rig, transit, utility, industrial and other diverse applications. Commitment Our commitment to meet even the most stringent demands of our customers with the most advanced products is demonstrated by: Technical leadership through the research and development of Low-Smoke, Zero-Halogen (LSZH) cabling systems which inhibit the spread of fire, smoke and toxic fumes Our leading role in the development of thermoset jackets which stand up to severe stresses of installation and operation in hostile environments Engineering expertise in the design and manufacture of hybrid cables Dedicated state-of-the-art manufacturing facilities Comprehensive Total Quality Management programs Expertise We play a dedicated role in the design and production of special configurations and jacketing systems for military cables. We have a fully qualified range of shipboard cables to MIL-PRF /13, 15, 16, 17, 18, 20, 21, 22, 23, 24, 25 and 26; additionally, our facilities have been awarded the MIL-STD-790 Product Assurance Program Certification. This program acknowledges and accepts in-house testing of fiber optic cabling system products and components from its inspected manufacturing facilities as full verification of compliance with QPL (Qualified Products List) specifications for military cables and accessories, by the Defense Supply Center, Columbus. We also manufacture aerospace cables qualified for military-, commercial- and space-flight use. These engineering challenges are met utilizing our rigorous design philosophy developed over decades of cable manufacturing experience. Knowledge Our knowledgeable sales and engineering staff can assist you in determining the right cable solution designed for high performance and reliability under adverse conditions. Some factors to consider beforehand are: Current and future bandwidth requirements Acceptable attenuation rate over distance Cable dimension requirements Environmental and mechanical requirements, i.e., ruggedness, flexibility, flame retardance, abrasion and chemical resistance, temperature extremes UL/NEC and IEC requirements and compatibility with existing systems Signal source, connectors and terminations Cost of installation By selecting us as your supplier, especially in specialized cabling systems, our products provide you with greater performance and in-service reliability, optimizing the life-cycle costs of your cabling system. Call us... we want to be part of your success. 39

47 Specialty & Tactical Cable Brand Rex Brand Specialty Cable BRAND REX BRAND NAVY SHIPBOARD OPTIC CABLES MIL-PRF CROSS REFERENCE LIST BRAND REX BRAND M85045/16-01 M85045/16-02 M85045/15-01P M85045/15-02P M85045/18-01P M85045/18-02P M85045/13-01P M85045/13-02P M85045/17-01P M85045/17-02P M85045/21-01 M85045/21-02 M85045/22-01 M85045/22-02 M85045/23-01 M85045/23-02 M85045/20-01L M85045/20-02L M85045/20-01F M85045/20-02F M85045/20-01M M85045/20-02M M85045/24-01 M85045/24-02 M85045/25-01E M85045/25-01S M85045/28-01E M85045/28-01S M85045/26-01E M85045/26-01S *QPL Pending APPLICABLE SPEC. DESCRIPTION PART OF S TYPE OC-1468 FC F Thermoplastic Multimode OC-1571 FC F Thermoplastic Singlemode OC-1369P FC F Thermoplastic Multimode OC-1577P FC F Thermoplastic Singlemode OC-1417P FC F Thermoset Multimode OC-1578P FC F Thermoset Singlemode OC-1423P FC F Thermoplastic Multimode OC-1576P FC F Thermoplastic Singlemode OC-1434P FC F Thermoset Multimode OC-1462P FC F Thermoset Singlemode OC-1651 FC F Outboard Multimode OC-1679 FC F Outboard Singlemode OC-1680 FC F Thermoplastic Multimode OC-1652 FC F Thermoplastic Singlemode OC-1681 FC F Outboard Multimode OC-1653 FC F Outboard Singlemode OC-1569 FC F Thermoset Multimode OC-1671 FC F Thermoset Singlemode OC-1570 FC F Thermoset Multimode OC-1672 FC F Thermoset Singlemode OC-1540 FC F Thermoset Multimode OC-1673 FC F Thermoset Singlemode OC-1682 FC F Thermoset Multimode OC-1654 FC F Thermoset Singlemode OC-1598 QPL 7-8mm Tubes Thermoset Blown Fiber OC-1701 QPL 7-8mm Tubes Thermoplastic Blown Fiber OC-1702 * 19-8mm Tubes Thermoset Blown Fiber OC-1703 * 19-8mm Tubes Thermoplastic Blown Fiber OC-1597 FC mm Tube Thermoset Blown Fiber OC-1704 FC mm Tube Thermoplastic Blown Fiber 40

48 Military Tactical Breakout Cable Specialty & Tactical Cable XX0021B1C XX0041B1C XX0061B1C XX0081B1C XX0101B1C XX0121B1C XX Denotes fiber type Typical Cross-Section Flame-Retardant Jacket Overall Strength Member 900µm Tight Buffer Fiber 2.4 mm Sub-Unit Central Strength Member COUNT SUB- UNITS DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) (6.6) 20 (29) 450 (2002) 149 (663) (7.4) 24 (36) 450 (2002) 149 (663) (8.6) 29 (43) 450 (2002) 149 (663) (10.0) 36 (54) 700 (3114) 231 (1028) (11.4) 46 (68) 900 (4003) 300 (1334) (12.2) 52 (78) 1100 (4893) 360 (1601) 6 Fibers MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) Product Construction: Fiber: 2-12 fibers 900µm tight buffer Color-coding per TIA/EIA 598B 2.0 mm jacketed sub-units Central Strength Member: Epoxy/glass rod Overall Strength Member: Aramid yarn Jacket: Black polyurethane Sequential footage markings* Features: Rugged individual fiber protection Easy-to-terminate sub-units Heavy-duty field applications Designed to military standards Color-coded units for identification Performance: Temperature: Storage -70 C (-94 F) to +85 C (+185 F) Operating -55 C (-67 F) to +85 C (+185 F) Minimum Bend Radius: 16 X OD Installation 8 X OD In-Service Maximum Crush Resistance: 251 lbs/in (440 N/cm) EIA/TIA Impact Resistance: 200 impacts EIA/TIA Flex Resistance: 2000 cycles EIA/TIA Applications: Military Tactical field use and commercial applications in re-deployable communication systems TV camera applications Mining and harsh environments needing Mechanical and Chemical Resistance Compliances: Tested to MIL-PRF *Sequential meter markings available upon request NOTE: Reference the Fiber Specifications and Fiber Selection Guide on page 2 for available fiber types. 41

49 Specialty & Tactical Cable Military Tactical Distribution Cable Product Construction: Fiber: 2-12 fibers 900µm tight buffer Color-coding per TIA/EIA 598B Central Strength Member: Epoxy/glass rod Overall Strength Member: Aramid yarn Jacket: Black polyurethane Sequential footage markings* Features: Lightweight, rugged Withstands repeated flexing Compact design for ease of deployment Excellent mechanical protection for the fibers Designed to military standards Performance: Temperature: Storage -70 C (-94 F) to +85 C (+185 F) Operating -55 C (-67 F) to +85 C (+185 F) Minimum Bend Radius: 16 X OD Installation 8 X OD In-Service Maximum Crush Resistance: 251 lbs/in (440 N/cm) EIA/TIA Impact Resistance: 200 impacts EIA/TIA Flex Resistance: 2000 cycles EIA/TIA Applications: Military Tactical field use and commercial applications in re-deployable communication systems TV camera applications Mining and harsh environments needing Mechanical and Chemical Resistance Compliances: Tested to MIL-PRF XX0021ANC XX0041ANC XX0061ANC XX0081ANC XX0101ANC XX0121ANC XX Denotes fiber type Typical Cross-Section Jacket Tight Buffer Fiber Component Aramid Yarn Strength Member COUNT SUB- UNITS DIAMETER in (mm) WEIGHT lbs/1000' (kg/km) MAXIMUM TENSILE LOAD INSTALLATION IN-SERVICE lbs (N) lbs (N) (5.0) 15 (22) 400 (1779) 130 (578) (5.6) 19 (28) 400 (1779) 130 (578) (6.09) 21 (31) 400 (1779) 130 (578) (6.4) 25 (37) 400 (1779) 130 (578) (6.6) 30 (45) 450 (2002) 149 (663) (6.6) 34 (51) 450 (2002) 149 (663) 6 Fibers *Sequential meter markings available upon request NOTE: Reference the Fiber Specifications and Fiber Selection Guide on page 2 for available fiber types. 42

50 Blolite Blown Fiber Technology Revolutionizing Fiber Networks Blolite Blown Fiber Technology Blolite blown optical fiber technology provides unparalleled flexibility in network design anticipating and facilitating future changes as the network evolves. The Blolite system delivers the ultimate fiber solution for backbone and Fiber-To-The-Desk (FTTD) applications. The best long-term choice for your business... Blolite blown optical fiber technology will continue to provide significant and measurable time, cost and service benefits to the network throughout its life cycle. How Does It Work? Small, flexible, empty Microduct tubes are initially installed, and compressed air is then used to blow the optical fiber through the Microducts. As a result of our material and design technology, our blown fiber system offers the opportunity to install fiber through difficult runs and further distances where installation of traditional optical fiber would be challenging and expensive. This enhanced feature sets our system apart from others available in today s market. Microduct eliminates potential damage to fibers during installation since empty Microducts are installed initially and fiber is blown in later. Because the Blolite system is based upon simultaneously blowing individual fibers into each Microduct, designers have maximum flexibility regarding the number and type of fibers per Microduct. Color-coded fibers are typically supplied on master spools and cut to length during the blowing process. If necessary, routes can even be reconfigured on the fly during the installation process. Blolite Blown Optical Fiber System Outdoor Multiduct Duct/Fiber Interconnect Center Indoor Riser Multiduct Indoor Plenum Multiduct Blolite Fiber Multiduct Distribution Cabinet BLOLITE is a trademark of Novar plc and used under license. 43

51 Blolite The Blolite System Advantage Pay as you grow Deferred Investment Future-proof your network by installing only the fiber you need today, reserving Microduct capacity for tomorrow s requirements. Design tactically to meet present needs, but build strategically for the long term. Pay as you grow. Extraordinary Design Flexibility The Blolite system can adapt to any network architecture or topology changes over the life of your network. Quickly and economically add new destinations, relocate routes, change fiber types and counts, reconfigure LANs and add new services and technologies, as required. New sections of Microduct can be spliced to existing Microduct with a simple push-fit connector. Adaptable to Any Environment Blolite technology is compatible with any network topology and nearly every local area network installation environment. Moves, Adds and Changes (MACs) can be accomplished with minimal workplace disruption as your network evolves and changes. Installation Ease Microduct tubing and simple push-fit connectors make building a network infrastructure simple. Blolite eliminates potential damage from pulling and overstressing fiber optic cables, as well as resulting costs, delays or latent failures. Point-to-point links, easily achieved with Blolite for situations in which conventional fiber optic cable would require splices, mean lower attenuation, higher performance and increased system integrity. Capability for Quick Recovery Disaster recovery from physical damage to the cabling infrastructure with the Blolite system means days versus weeks, resulting in minimal downtime and labor costs. Only the damaged section of Microduct is removed and replaced, then within minutes, new optical fiber is blown in, then terminated. Much faster and a far less costly disaster recovery is one of the many obvious benefits of the Blolite blown fiber system. Improved Reliability Because Microduct is installed empty, there is no risk of fiber damage during installation. Optical fibers are blown into place, rather than pulled, with zero tensile stress on the fiber during the installation process. Because point-to-point links are easily accommodated, fiber splice points can be eliminated, lowering attenuation and increasing system performance and integrity. Installation Cost Savings Only two people are needed to blow in the optical fiber. Fiber terminations are typically quicker than with conventional cable since no time needs to be devoted to cable preparation. Additionally, termination and testing is simplified with no dark fiber to contend with. 44

52 Blolite Products Blolite Blolite Blowable Fiber The Blolite system offers the highest quality of Corning optical fiber in standard types of multimode 62.5/125, 50/125 (1 Gb/s) or 50/125 (10 Gb/s), and singlemode 9/125, all with a special blowable coating and available in 12 colors. The fibers are stripped and terminated with standard tools and compatible with standard fiber optic connectors. Catalog Number Description MULTIMODE 50/125 (1 Gb/s) BLUE MULTIMODE 50/125 (1 Gb/s) ORANGE MULTIMODE 50/125 (1 Gb/s) GREEN MULTIMODE 50/125 (1 Gb/s) BROWN MULTIMODE 50/125 (1 Gb/s) SLATE MULTIMODE 50/125 (1 Gb/s) YELLOW MULTIMODE 50/125 (1 Gb/s) RED MULTIMODE 50/125 (1 Gb/s) VIOLET MULTIMODE 50/125 (1 Gb/s) WHITE MULTIMODE 50/125 (1 Gb/s) BLACK MULTIMODE 50/125 (1 Gb/s) ROSE MULTIMODE 50/125 (1 Gb/s) AQUA MULTIMODE 62.5/125 BLUE MULTIMODE 62.5/125 ORANGE MULTIMODE 62.5/125 GREEN MULTIMODE 62.5/125 BROWN MULTIMODE 62.5/125 SLATE MULTIMODE 62.5/125 YELLOW MULTIMODE 62.5/125 RED MULTIMODE 62.5/125 VIOLET MULTIMODE 62.5/125 WHITE MULTIMODE 62.5/125 BLACK MULTIMODE 62.5/125 ROSE MULTIMODE 62.5/125 AQUA Blolite Blowable Fiber Blolite Microduct Microducts are empty plenum and non-plenum tubes that provide a pathway/conduit for blowing the fiber through the network. Up to 12 fibers can be installed simultaneously into each Microduct using the Blolite installation technique. Catalog Number Description MULTIMODE 50/125 (10 Gb/s) BLUE MULTIMODE 50/125 (10 Gb/s) ORANGE MULTIMODE 50/125 (10 Gb/s) GREEN MULTIMODE 50/125 (10 Gb/s) BROWN MULTIMODE 50/125 (10 Gb/s) SLATE MULTIMODE 50/125 (10 Gb/s) YELLOW MULTIMODE 50/125 (10 Gb/s) RED MULTIMODE 50/125 (10 Gb/s) VIOLET MULTIMODE 50/125 (10 Gb/s) WHITE MULTIMODE 50/125 (10 Gb/s) BLACK MULTIMODE 50/125 (10 Gb/s) ROSE MULTIMODE 50/125 (10 Gb/s) AQUA SINGLEMODE BLUE SINGLEMODE ORANGE SINGLEMODE GREEN SINGLEMODE BROWN SINGLEMODE SLATE SINGLEMODE YELLOW SINGLEMODE RED SINGLEMODE VIOLET SINGLEMODE WHITE SINGLEMODE BLACK SINGLEMODE ROSE SINGLEMODE AQUA Catalog Number FC FC FC FC Microduct Description OC-5MM-OFNP OC-5MM-OFNR OC-8MM-OFNP OC-8MM-OFNR 45

53 Blolite Blolite Products Blolite Multiduct Multiduct is a jacketed bundle of Microduct tubing available in 2-, 4-, 7- or 19-way configurations. Multiduct cable is offered in plenum and non-plenum for indoor and dry duct outdoor installations or in an armored direct buried configuration. Plenum Rated Duct Catalog Number Description FC OC-2X5MM-OFNP FC OC-4X5MM-OFNP FC OC-7X5MM-OFNP Riser Rated Duct Catalog Number Description FC OC-2X5MM-OFNR FC OC-4X5MM-OFNR FC OC-7X5MM-OFNR FC OC-2X8MM-OFNR FC OC-4X8MM-OFNR FC OC-7X8MM-OFNR Multiduct Cable Outdoor Duct Catalog Number Description FC OC-2X5MM-OSP FC OC-4X5MM-OSP FC OC-7X5MM-OSP FC OC-19X5MM-OSP FC OC-2X8MM-OSP FC OC-4X8MM-OSP FC OC-7X8MM-OSP FC OC-19X8MM-OSP Outdoor Direct Buried Catalog Number Description FC OC-19X5MM-OSP-DBA (ALUMINUM) FC OC-19X5MM-OSP-DBS (STEEL) FC OC-19X8MM-OSP-DBA (ALUMINUM) FC OC-19X8MM-OSP-DBS (STEEL) Blolite Connectors and Accessories Simple push-fit connectors join the Microduct sections and extend the Microduct network to each destination. A transparent center section of the connectors permits visual inspection to verify if the path is empty or populated with optical fiber. Microduct Accessories Catalog Number Description END CAPS 8MM END CAPS 5MM STRAIGHT CONN 5MM STRAIGHT CONN 8MM BULKHEAD CONN 5MM MM>5MM REDUCER TEE CONN 5MM TEE CONN 8MM CONN PLUG 5MM CONN PLUG 8MM TUBE CUTTER TUBE CUTTER BLADES SPLITTER KIT SPLITTER KIT Straight Connector Blolite Installation Equipment The Blolite installation equipment kit (retail only) consists of an Air Supply Conditioning Unit (ACU) complete with filtration and air-drying units, and the Installation Module a blowing head utilizing a mechanically driven system to feed the fibers into the Microduct. A lightweight Tripod is the third component used to support the Installation Module. The equipment operates on standard compressed air at safe, low pressures. 46 Installation Equipment

54 NextGen Brand Accessories and Assemblies We offer termination accessories to complement our full line of fiber optic cables. These accessories include splitter kits (sometimes referred to as fan-outs) and breakout kits. Loose Tube/Central Tube Splitter Kits Our splitter kits are suitable for loose tube and central tube cables. This convenient and cost-effective termination method consists of an easily accessible splitter block with 900µm breakout tubes. The loose tube or central tube is secured to the splitter block and each 250µm fiber is routed through a 900µm breakout tube. This allows fiber termination to any connector with a 900µm boot. The breakout tubes are color-coded for fast identification. Splitter Kit Ordering Information Loose Tube Splitter Kit 3.0mm Breakout Tubes Central Tube Splitter Kit 3.0mm Breakout Tubes COUNT P/N COUNT P/N 6 12 SPK-06/C SPK-12/C 6 12 SPKU-06/C SPKU-12/C Loose Tube Splitter Kit 900micron Breakout Tubes Central Tube Splitter Kit 900micron Breakout Tubes COUNT P/N COUNT P/N 6 12 SPK-06/900/C SPK-12/900/C 6 12 SPKU-06/900/C SPKU-12/900/C Loose Tube Breakout Kits Loose tube cables with one fiber per tube require specially designed splitter kits to allow direct termination of connectors. Fiber cables with one fiber per tube are identified by the number 3 in the sixth character of the cable part number (for example, CG0023M1A-DWB). Tight Buffer Breakout Kits Breakout kits are suitable for distribution-style premises cables with 900µm tight buffered fibers. The kits consist of 3mm breakout tubes that provide additional fiber protection and a contact point for termination with connectors. The breakout tubes are secured to the cable for long-term performance. All breakout tubes are color-coded. Breakout Kit Ordering Information (1 fiber/loose tube) Loose Tube Breakout Kit 3.0mm Breakout Tubes COUNT 6 12 Tight Buffer Breakout Kit COUNT 6 12 P/N BOKL-06/C BOKL-12/C Tight Buffer Breakout Kit Ordering Information P/N BOKP-06/C BOKP-12/C 47

55 NextGen Brand Accessories and Assemblies Accessories and Assemblies Assemblies Factory Installed Terminations The assembly department can provide factory-installed connectors on the fiber optic cable of your choice. Stock- and custommanufactured cables can be terminated with a variety of industry-standard connectors to meet the needs of your network. To receive a custom quote, provide Customer Service with the type and length of cable required, the connector choice for the outside end of the cable and the connector choice for the inside end. Pulling eyes are installed on all assemblies to protect the connectors during shipping and installation. Part Number System ASSEMBLY PART SYSTEM CABLE PART OUTSIDE END CONNECTOR INSIDE END CONNECTOR CABLE LENGTH PULLING EYES Digits 1-9 AAAAAAAAA-YY-XXX-EE Y Y XXX EE CONNECTOR OPTIONS CODE ST Connector with Ceramic Ferrule C FC Connector F ST Connector with Stainless Ferrule S SC Connector U MT/RJ M EXAMPLE: 500ft of cable part number CG0064UNA with stainless ST Connectors on the outside end and SC connector on the inside end. CG0064UNA-SU-500-EE PULLING EYE ASSEMBLY P/N TERMINATIONS BOOT DIA. PULLING LOAD PEA-02 PEA-6 PEA-12 PEA-XX 1-2 (Zipcord) 3-6f 7-12f 13f and up 3/4" 3/4" 1.0" 1.0" 75 lbs 75 lbs 100 lbs 125 lbs Note: Fibers are staggered when greater than 2 48

Join the Wire Wizard for a quick, informative tour showing the interactive features of our catalogs

Join the Wire Wizard for a quick, informative tour showing the interactive features of our catalogs WELCOME Join the Wire Wizard for a quick, informative tour showing the interactive features of our catalogs On-Line Catalog Features View the catalog in full screen mode by using the far left expansion

More information

Fiber Optic Cable FOR VOICE AND DATA TRANSMISSION

Fiber Optic Cable FOR VOICE AND DATA TRANSMISSION Fiber Optic Cable FOR VOICE AND DATA TRANSMISSION Fiber Optic Cable Products This catalog contains in-depth information on the General Cable line of fiber optic cable for voice, video and data transmission.

More information

Fiber Optic Cable FOR VOICE AND DATA TRANSMISSION

Fiber Optic Cable FOR VOICE AND DATA TRANSMISSION Fiber Optic Cable FOR VOICE AND DATA TRANSMISSION Fiber Optic Cable Products This catalog contains in-depth information on the General Cable line of fiber optic cable for voice, video and data transmission.

More information

FREEDM Loose Tube Interlocking Armored Cables

FREEDM Loose Tube Interlocking Armored Cables features and benefits Flexible, interlocking armor design Gel-free waterblocking technology Color-coded tubes and fibers UV-resistant, flameretardant jacket UV-Resistant Flame-Retardant Outer Jacket InterlockingArmor

More information

Industry solutions: Broadcast

Industry solutions: Broadcast Industry solutions: Broadcast Bc 2 Industry solutions: Broadcast Optical Cable Corporation s broad range of Fiber Optic Broadcast Cables are specifically designed for real-time transmission of high definition

More information

LD Series High Performance Loose Tube Fiberoptic Cables

LD Series High Performance Loose Tube Fiberoptic Cables Fiberoptic Cables Catalog LD Series High Performance Loose Tube Fiberoptic Cables APPLICATIONS Long-distance outside plant telephone, CATV as well as data communications Direct burial and installation

More information

Mining and Petrochemical Fiber Optic Cables

Mining and Petrochemical Fiber Optic Cables Features and Benefits Loose construction Stable and highly reliable transmission parameters Waterblocking technology Allows efficient and craft-friendly cable preparation in outdoor or indoor/outdoor applications

More information

AFL Telecommunications

AFL Telecommunications ' portfolio of fiber optic cable products is more impressive than any other telecommunications company in the world. But with AFL, you're getting more than just quality products. You're hiring a team of

More information

INDUSTRY SOLUTIONS: MINING

INDUSTRY SOLUTIONS: MINING INDUSTRY SOLUTIONS: MINING MS 2 INDUSTRY SOLUTIONS: MINING Optical Cable Corporation is built on a tradition of innovation and dependability. In the early 1980s, Optical Cable Corporation was a pioneer

More information

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014 Sumitomo Cable Specification SE-*RU Litepipe Ribbon Indoor Plenum Cable OFNP Rated Central Tube Cable with 12-432 Optical Fibers Issued: December 2014 78 Alexander Drive, Research Triangle Park, NC 27709

More information

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011 SECTION 271323 - COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING PART 1 - GENERAL 1.1 DESCRIPTION A. This section provides the specifications for the work related to the optical fiber system in the project.

More information

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş. Technical Specification Revision/Date: 04/04.15 By N.KARAAĞAÇ Date : 27 February 2015 Cable Type HES Cable Product Number :, Outdoor F/O Cable :FOZZXXXSJSA41JYY (ZZ: fiber type G652=SD, G657 A1 = A1, G657

More information

SOLO ADSS Short-Span Cables, Fibers

SOLO ADSS Short-Span Cables, Fibers features and benefits Loose tube design Self-supporting Track-resistant jacket available Innovative waterblocking cable core SOLO ADSS Cable Drawing ZA-2615 Stable performance and compatibility with all

More information

OPTICAL FIBRE CABLE NETWORK 2004/1

OPTICAL FIBRE CABLE NETWORK 2004/1 OPTICAL FIBRE CABLE NETWORK 2004/1 HELKAMA OPTICAL FIBRE CABLES Cabled optical fibre characteristics OS1 singlemode fibre SM ITU-T G.652 Mode field diameter 1310nm 9.3+/-0.5µm Mode field eccentricity 1.0

More information

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution

UC FIBRE Optical Fibre Cable a fast, reliable and always available part of the Draka Datacom Solution. Be ready for the future: Draka Datacom Solution Be ready for the future: Draka Datacom Solution Modern networks face stiff demands. They must be fast and reliable, resist fire and not interfere with other equipment. Optical Fibre Cable a fast, reliable

More information

Product Catalogue. Fibre Optic Cable

Product Catalogue. Fibre Optic Cable Product Catalogue Fibre Optic Cable version 2017 Empowering businesses through innovative network solutions. We have been pushing boundaries and providing innovative products and solutions to clients around

More information

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY - SYMBOLS AND THE MEANING OF THE SYMBOLS FOR FIBRE OPTIC CABLES - SINGLE LOOSE TUBE, SINGLE SHEATH, NON METALLIC

More information

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET June 30th, 2015 Rev E2 Optic Interconnect Cables Simplex 1 900um Buffered Aramid Yarn Strength Members 2 s 900um Buffered Aramid Yarn Strength Members 900um Buffered 900um Buffered Aramid Yarn Strength

More information

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D) 2-3, Marunouchi 2-chome, Chiyoda-ku, Tokyo 100-8322, Japan No. FB-KL4001C for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D) Aug 2014 1 1. General This specification describes

More information

FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY

FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY FIBER OPTIC CABLE CUT TO YOUR EXACT SPECS TO SAVE YOU TIME AND MONEY ADVANTAGES OF FIBER OPTIC CABLE Fiber optic cable is the preferred choice for backbone and horizontal applications. Black Box provides

More information

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014 Sumitomo Cable Specification SE-*DB DriTube Ribbon / Armorlux Sheath Cable 100% Dry - Armored Central Tube Ribbon Cable with 12-576 Fibers Issued: January 2014 78 Alexander Drive, Research Triangle Park,

More information

Table of Contents. Specifying AFL Premise Optical Cables Outdoor. Enterprise. Interconnect. MicroCore. Indoor.

Table of Contents. Specifying AFL Premise Optical Cables Outdoor. Enterprise. Interconnect. MicroCore. Indoor. Table of Contents Specifying AFL Premise Optical Cables... 2 Enterprise Fiber-In-A-Box... 3 Interconnect Simplex Cable....................................... 4 Zipcord and DUAL-Link Cable... 6 Furcation

More information

Empowering businesses through innovative network solutions.

Empowering businesses through innovative network solutions. Empowering businesses through innovative network solutions. We have been pushing boundaries and providing innovative products and solutions to clients around the world for nearly two decades. Our experience

More information

Number of Fiber 6 Core 12 Core 24 Core 48 Core

Number of Fiber 6 Core 12 Core 24 Core 48 Core Order Information OUTDOOR OFC-ADSS-MM (OM3, 50/125) LOOSE TUBE-BLACK Number of Fiber 6 Core 12 Core 24 Core 48 Core Part Number 74060006 74060012 74060024 74060048 1. General 1. Scope This specification

More information

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE SPEC NO. TEC-OPTIC-81101A(Rev.4)-2014.07 TECHNICAL PROPOSAL FOR OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE ( Span length : Max. 100m ) APPROVED BY : J.Y. LEE / HEAD OF TEAM ENGINEERING TEAM

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more information please call 1-800-Belden1 See Put-ups and Colors Related Documents: No.10 for Fiber Optic Cables.pdf Cable Characteristics: DESCRIPTION: 2 to 12 optical fibers, Central gel filling

More information

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014 Sumitomo Cable Specification SE-*RD Litepipe Ribbon / ADS Sheath Cable All-Dielectric Ribbon Cable with 12-864 Fibers Issued: April 2014 78 Alexander Drive, Research Triangle Park, NC 27709 Phone (919)

More information

SPECIFICATION. Optical Fiber Cable

SPECIFICATION. Optical Fiber Cable SPECIFICATION Optical Fiber Cable (GYFS) Prepared by Zhang xin Approved by Yin peng xiang 1 1 Product description GYFS is gel-free, single-jacket, single-armored cable for direct burial and duct GYFS is

More information

1. General. 1. Scope. 2. Quality Assurance

1. General. 1. Scope. 2. Quality Assurance 1. General 1. Scope 2. Quality Assurance This specification covers the construction and properties of 50/125 um Multimode (Graded-index, OM2), anti-rodent self-supporting (ARSS), single jacket, single

More information

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents WESLEYAN U N I V E R S I T Y Facilities 170 Long Lane Middletown, Connecticut 06457 (860) 685-3476 FAX (860) 685-3101 ADDENDUM #3 Date: March 4, 2013 Project: To: CFA A Rehearsal Hall AHU Replacement Annual

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION ISSUED : OCT. 02, 2006 PAGE : 1 OF 9 REV. : 1 TECHNICAL SPECIFICATION FOR GST 2006-043A LOOSE TUBE DRY CORE CABLE SINGLE JACKET/SINGLE ARMOR (SJSA CABLE) Prepared By : Oh-Heoung Kwon Engineer Optical Technical

More information

GenSPEED Category 5e Cables 3

GenSPEED Category 5e Cables 3 Datacom GenSPEED Category 5e Cables 3 GenSPEED Category 5e cables are available in a wide variety of performance levels and constructions. With many options to pick from, you can select the GenSPEED Category

More information

Micro duct Cable with HDPE Sheath for Installation by Blowing

Micro duct Cable with HDPE Sheath for Installation by Blowing Optical Fiber Cable Technology Specification INTERNAL Optical Fiber Cable Specification Micro duct Cable with HDPE Sheath for Installation by Blowing GCYFY-12/24/36/48/72/96/144/288/432/576B1.3 V7.0 2018-3-20,CCopyright.

More information

Number of Fiber 6 Core 12 Core. Part Number

Number of Fiber 6 Core 12 Core. Part Number Order Information OUTDOOR OFC-Drop Wire, MM (OM2) (50/125) LOOSE TUBE BLACK Number of Fiber 6 Core 12 Core Part Number 74550006 74550012 1. General 1. Scope 2. Quality Assurance This specification covers

More information

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks OPTICAL FIBRE CABLES for very-high bit transmission and FTTx networks OPTICAL FIBRE CABLES SILEC CABLE REFERENCES AND KNOW-HOW Since 1983, Silec Cable has successfully supplied the major telecom operators,

More information

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information. GUXT Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 4 6 8 12 16 24 62.5/125-OM1

More information

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE Revision No.:00 Date: 08.03.2010 SPECIFICATION OF 192F SM LOOSE TUBE, DRY CORE MINI CABLE PART NO.:D-192/SM/MTY(F)-MFN-O9.1 Checked By: Pavan Maheshwari Process Associate Design & Development Team Approved

More information

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits GBRE Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 84 96 62.5/125-OM1 GBRE184 GBRE196 -OM2 BW /1200 GBRE284

More information

Number of Fiber 12 Core 24 Core 48 Core. Part Number

Number of Fiber 12 Core 24 Core 48 Core. Part Number Order Information OUTDOOR OFC-FIG.8, MM (OM2), (50/125) LOOSE TUBE BLACK 1. General 1. Scope 2. Quality Assurance Number of Fiber 12 Core 24 Core 48 Core Part Number 63460012 63460024 63460048 This specification

More information

OPTICAL CABLE FIBER-LAN INDOOR

OPTICAL CABLE FIBER-LAN INDOOR OPTICAL CABLE FIBER-LAN INDOOR Product Type Optic Cable Construction RoHS-2 Compliant Dielectric Tight Buffer Singlemode or Multimode Description Optical cable with singlemode or multimode optical fibers

More information

Ø 1000 * 588 mm 50 kg

Ø 1000 * 588 mm 50 kg GOCN Central Loose Tube Cables Outdoor Corrugated Steel Tape Armor (CST) A-DQ(ZN)(SR)2Y Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 4 6 8 12 16 24 62.5/125-OM1

More information

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING SUMITOMO PRODUCT SPECIFICATION FutureFLEX TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100,

More information

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3 Version GYFTY-V1.0 Optical Fibre Cable Technical Specification Duct Cable GYFTY-24,48,72,144,216B1.3 Yangtze Optical Fibre and Cable Joint Stock Limited Company All rights reserved 1. Scope This Specification

More information

Single-Source. SOLUTIONS Serving the Needs of the Industrial Automation Market

Single-Source. SOLUTIONS Serving the Needs of the Industrial Automation Market Single-Source SOLUTIONS Serving the Needs of the Industrial Automation Market Cord Products Industrial Cables Datacom Cables Fiber Optic Cables Electronic Cables Specialty Cables HERE TO SERVE For more

More information

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information GUWN Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 4 6 8 12 16 24

More information

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE Revision No.:01 Date: 07.10.06 SPECIFICATION OF 96F SM LOOSE TUBE, DRY CORE MINI CABLE PART NO.:D-96/SM/MTY(F)-MFN-O6.3 Checked By: Pavan Maheshwari Process Associate Design & Development Team Approved

More information

Revision No. 4 Page No. Page 1 of 7

Revision No. 4 Page No. Page 1 of 7 Page No. Page 1 of 7 Single Mode Optical Fibre Cables With Loose Fibres in Stranded Tubes And Corrugated Steel tape Armouring For Duct Applications LITE KABEL SDN. BHD. reserves the right to make changes

More information

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING SUMITOMO PRODUCT SPECIFICATION FutureFLEX TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100,

More information

HITRONIC Optical Transmission Cable

HITRONIC Optical Transmission Cable HITRONIC Optical Transmission Cable POF - Polymer Optical Fiber 263 PCF - Plastic-Clad Fiber 267 GOF - Glass Optical Fiber 269 HITRONIC Optical Transmission Cable OPTICAL TRANSMISSION CABLE POF - Polymer

More information

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS 10 Gigabit Ethernet is nowadays viable solution for destinations with very high data traffic concentration like data center, server farms, MAN s and backbones. Premium Line Category 6A Cabling Solutions

More information

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer Spec No.: ZTT 45012 Revision: 2 Date: Oct 3, 2014 TECHNICAL SPECIFICATION Optical Fiber Cable (Reference: NBR 14566) Designer Senior Technical Manager Approver Chief Technical Engineer Jiangsu Zhongtian

More information

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications E2O540JCASS-12CT MICFIBR-12.7MB MICFIBR-12.7MB DUCT DUCT E2O540JCASS- Product Classification Brand E 2 O E 2 O Coaxial/Fiber/Microduct Hybrid Buried Cable E O is a solution that enables service providers

More information

MPS Webinar Technical Series

MPS Webinar Technical Series MPS Webinar Technical Series Making Connections: Navigating Fiber Optic Cabling and Interconnection Requirements microwave photonic systems Expand Your RF Horizons Introduction Microwave Photonic Systems

More information

SPECIAL SPECIFICATION 6559 Telecommunication Cable

SPECIAL SPECIFICATION 6559 Telecommunication Cable 2004 Specifications CSJ 0015-09-147, etc. SPECIAL SPECIFICATION 6559 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing, training,

More information

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES SUMITOMO PRODUCT SPECIFICATION FutureFLEX TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100, Raleigh, NC 27610 (919) 541-8100

More information

Table of Contents. Open Matrix System (OMS) 1-2

Table of Contents. Open Matrix System (OMS) 1-2 Company Profile Addison cabling system originated as a cabling solution produced and marketed by Caledonian Cables Ltd located at Sussex, England. Founded in 1978, Caledonian Cables originally entered

More information

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS 10 Gigabit Ethernet is nowadays viable solution for destinations with very high data traffic concentration like data center, server farms, MAN s and backbones. Need of 10 Gigabit Service Application as

More information

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING SUMITOMO PRODUCT SPECIFICATION FutureFLEX TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100, Raleigh, NC 27610

More information

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14 Table of contents About Nexans 3 About Berk-Tek 4 Hyper Plus 5e Cat 5e UTP 5 HyperPlus 5e Plenum 6 Hyper Plus 5e Riser 10 HyperPlus 5e Patch 14 HyperPlus 5e OSP 18 22 7/10/07 - http://www.berktek.com Page

More information

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV FIBER OPTIC CABLES ASTEL offers an innovative and wide range of Optical Fiber Cables from 4 Fiber to 144 Fibers for broadband networks. ASTEL offers variety of models from Uni-Tube construction, to Stranded

More information

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS) SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS) No. FT-S16274 Version: A (ITU-T Rec. G.652.D) Futong Group Communication Technology (Thailand) Co., Ltd. All Right Reserved Add: No.7/324, Moo 6, T.Mabyangporn

More information

SPECIAL SPECIFICATION 8540 Telecommunication Cable

SPECIAL SPECIFICATION 8540 Telecommunication Cable 2004 Specifications CSJ 0914-00-307 & CSJ 0914-25-003 SPECIAL SPECIFICATION 8540 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing,

More information

CATEGORY 6 CABLING SOLUTIONS

CATEGORY 6 CABLING SOLUTIONS With over 20 years experience and know-how on communicating products design & developing, Premium Line has built maturity systems both in high tech develop and research center & complete structural quality

More information

PATCH CORDS, PLUGS & CABLES

PATCH CORDS, PLUGS & CABLES PATCH CORDS, PLUGS & CABLES 3.1 SECTION CONTENTS Modular Cords...3.2 Cable Assemblies...3.3 Plugs & Connectors...3.4 Bundled Cable...3.5 Category 5e & 6 UTP Cable...3.6 Coax Cable...3.7 Fiber Optic Cable...3.8

More information

Table of Contents. Teldor Cables and Systems Ltd.

Table of Contents. Teldor Cables and Systems Ltd. Fiberoptic Cable Catalog Table of Contents 2 New Cables FTX Series Microduct Fiberoptic Cables for Outdoor FTTH Applications 3 Outdoor Cables LD Series High Performance Loose Tube Fiberoptic Cable 6 ADS

More information

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting) 2004 Specifications CSJ 0086-14-046 SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting) 1. Description. Furnish, install, splice, field terminate, and test the fiber optic cables. 2. Materials.

More information

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12 Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12 Our I-IFLRF20 series is a wideband RF over fiber link that provides optical transport of RF signals in radars, satcom, EW/ECM and other antenna remoting

More information

The Light Connection Inc.

The Light Connection Inc. Optic and Tubing Manufacturer The Light Connection Inc. 2018 Product Catalog 1 888 571 7111 www.thelightconnection.com Welcome to The Light Connection, Inc. A Message from the President The Light Connection

More information

TELECOM SOLUTIONS SOLUTIONS CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

TELECOM SOLUTIONS SOLUTIONS CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS TELECOM SOLUTIONS SOLUTIONS CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 1930 TKF developed from a cable producer to

More information

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES SUMITOMO PRODUCT SPECIFICATION FutureFLEX TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100, Raleigh, NC 27610 (919) 541-8100 or 1-800-358-7378

More information

Instrumentation & copper telecom cables

Instrumentation & copper telecom cables Instrumentation & copper telecom cables Nestor Cables is a Finnish highly appreciated cable manufacturer whose innovative solutions are relied on by several global companies around the world. Nestor Cables

More information

5O years of innovation and leadership.

5O years of innovation and leadership. 5O years of innovation and leadership. At Mohawk/CDT, the future of connective technology is already a reality...with copper, fiber and composite cabling systems, supporting the telecommunications infrastructure

More information

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH 1 1 9.41 115 0 Pretium EDGE 143 RFP LC Uniboot to RFP LC Uniboot Patch Pretium EDGE Solutions jumpers are integrated reverse -polarity uniboot duplex assemblies that meet the high -density space requirements

More information

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11 Table of contents About Nexans 3 About Berk-Tek 4 LANmark-1000 Cat 6 UTP 5 LANmark-1000 Category 6 Plenum 6 LANmark-1000 Category 6 Riser 11 LANmark-1000 Category 6 Patch 16 21 7/10/07 - http://www.berktek.com

More information

Special Specification 6242 Special Fiber Optic Cable

Special Specification 6242 Special Fiber Optic Cable Special Specification 6242 Special Fiber Optic Cable 1. DESCRIPTION 2. MATERIALS The contractor to install, splice, field terminate, test and document all fiber systems. A. General Requirements. Provide

More information

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE SUMITOMO PRODUCT SPECIFICATION FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100, Raleigh, NC 27610 (919) 541-8100 or 1-800-358-7378 www.sumitomoelectric.com.com

More information

Panduit Opti-Core Fiber Optic Cable

Panduit Opti-Core Fiber Optic Cable Panduit Opti-Core iber Optic Cable High-Speed iber Cabling Systems Panduit provides high bandwidth and mission-critical physical infrastructures in data center, enterprise, and campus networks with comprehensive

More information

Combining Value and Performance Like No One Else

Combining Value and Performance Like No One Else Combining Value and Performance Like No One Else SUPERIOR ESSEX believes that its premises wire and cable products should provide a total user experience that is unequaled in the industry. That is why

More information

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue. Description: OZLINX CAT5e cable has a guaranteed performance; exceeds the Category 5e performance requirements and provides positive PSACR up to 155MHz for bandwidth requirement in the future. Product

More information

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH 1 1 9.41 115 0 Pretium EDGE 143 RFP LC Uniboot to RFP LC Uniboot Patch Pretium EDGE Solutions jumpers are integrated reverse -polarity uniboot duplex assemblies that meet the high -density space requirements

More information

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

SPECIAL SPECIFICATION 6191 Fiber Optic Cable 2004 Specifications CSJ 0014-02-014, etc SPECIAL SPECIFICATION 6191 Fiber Optic Cable 1. Description. Furnish, install, splice, field terminate, and test the fiber optic cables. 2. Materials. A. General

More information

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012 STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE Publication S-115-730 First Edition - June 2012 Published By Insulated Cable Engineers Association, Inc. Post Office Box 1568 Carrollton, Ga 30112,

More information

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK 1. General 1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK 2. Quality Assurance This specification covers the construction and properties of all-dielectric selfsupporting (ADSS), single jacket, dry

More information

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2 Product Catalogue Fiber Optic Assemblies & Adapters Table of Contents 1. General Description... 2 2. Connectors... 3 2.1 SC/UPC... 3 2.2 SC/APC... 3 2.3 FC/UPC... 3 2.4 FC/APC... 3 2.5 ST/UPC... 3 2.6

More information

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7 Page /7 Illustrations Product description Pre-terminated installation cables (VIK) are fiber optic cables with connectors on one or both ends that are made in manual singleitem production at METZ CONNECT

More information

TENDER SUMMARY. Tender Title:

TENDER SUMMARY. Tender Title: TENDER SUMMARY Tender Title: Tender Ref: Closing Date: OPEN TENDER FOR THE SUPPLY OF FIBER OPTIC CABLE 384 CORE LOOSE TUBE ( FOC 384C ) FOR TELEKOM MALAYSIA BERHAD ( TM ) LPM/2018/T/02/FOC 384C 23 February

More information

Customer-Owned Outside Plant

Customer-Owned Outside Plant Customer Premises Products (Enterprise) 3 Customer-Owned Outside Plant Fiber Optic Splice Case 2178 Series and Accessories 372 Fiber Optic Dome Splice Closure FD Series 376 Fibrlok II Universal Optical

More information

SECTION 4 TABLE OF CONTENTS

SECTION 4 TABLE OF CONTENTS Contents Introduction LC, SC and ST Series...4-2 Markets and Applications...4-2 International Standard Documents Compliance...4-2 LC Series Features and Benefits...4-3 LC Standard... 4-4 to 4-5 LC for

More information

1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK

1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK 1. General 1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK 2. Quality Assurance This specification covers the construction and properties of optical fiber three tubes stranded, dry core fiber

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data Description: 23 AWG Bonded-Pairs solid bare copper conductors, polyolefin insulation, PVC inner jacket, aluminum interlocked armor, industrial grade PVC jacket. Sequential marking at one meter intervals.

More information

CATEGORY 5e CABLING SOLUTIONS

CATEGORY 5e CABLING SOLUTIONS With the high speed data transmission requirement in LAN, 1998 IEEE ratified standard 802.3z defined protocol 1000BASE-T over Category 5e and higher level Ethernet cabling system. After that, with the

More information

SECTION FIBER OPTIC STATION CABLES

SECTION FIBER OPTIC STATION CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications shall include all labor necessary to perform and complete such construction, all materials and equipment incorporated

More information

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference MPO/MTP TRUNK CABLE FEATURES MTP (US Conec) brand or MPO standard compliant multifiber connector Connector's design complies with IEC 61754-7 standards 4, 8, 12 and 24-fiber with single mode and multimode

More information

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

Non-metallic Aerial Distribution Optical Cables for FTTH Networks Non-metallic Aerial Distribution Optical Cables for FTTH Networks Go Taki, 1 Akira Namazue, 1 and Ken Osato 1 One of the common practices to construct economical and efficient Fiber To The Home (FTTH)

More information

- Outdoor & Indoor Telephone Cables - Fiber Optic Cables - Electronic Control Cables - Control Cables - Data/LAN Cables - Coaxial Cables

- Outdoor & Indoor Telephone Cables - Fiber Optic Cables - Electronic Control Cables - Control Cables - Data/LAN Cables - Coaxial Cables ETK CABLE CO. which has been playing an active role in Global Cable Market since 1979, carries on its cable manufacturing activity in a production plant of 50.000 square meters in Sancaktepe-Istanbul.

More information

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM Content 1. General 5 2. The products of NC-1000 system 6 3. Mounting of the frame 8 4. Earthing of the frame 8 NC-1000 FIBRE OPTIC

More information

Purchase Now ANSI/ICEA S

Purchase Now ANSI/ICEA S STANDARD FOR OPTICAL FIBER OUTSIDE PLANT COMMUNICATIONS CABLE Publication S-87-640 Fourth Edition September 2006 Published By Insulated Cable Engineers Association, Inc. (ICEA) P.O. Box 1568 Carrollton,

More information

A Comparison of Dry Versus Gel Filled Optical Cables

A Comparison of Dry Versus Gel Filled Optical Cables Application Notes A Comparison of Dry Versus Gel Filled Optical Cables Author John Peters Issued December 2012 Abstract The dry cable design compares favorably with a wet design that uses a flooding compound

More information

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS Power and Control 26 1999 November/December IAEI NEWS T YPE BY RAVI GANATR This article discusses how the requirements in both the installation code and the product standard are utilized to manufacture

More information