ADVR-08. Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

Size: px
Start display at page:

Download "ADVR-08. Universal Hybrid Analog-Digital Voltage Regulator Operation Manual"

Transcription

1 Universal Hybrid Analog-Digital Voltage egulator Operation Manual Universal Hybrid Analog/Digital 2 lines sensing 8 Amp AV with multiple power input capability such as Full Harmonic (Compound Windings), Harmonic + Auxiliary Winding, PMG and HUN. Compatible with Leroy omer 449. P POWEWOLD LD Willows, Waterside, yhall, tamford, Lincs, PE9 4EY, UK el: info@sp-powerworld.com

2 ECION 1 : PECIFICAION ensing Input (E1, E2) External Volts Adjustment (V1, V2) Voltage Vac 1 phase +/- 4% 500 ohms 1 watt potentiometer Vac +/- 8% 1K ohms 1 watt potentiometer Vac Vac oft tart amp ime Frequency 50/60 Hz selectable 4 sec. Power Input (X1, X2) Over Excitation Protection Voltage Vac, 1 phase Inverse-time 170 +/- 5 power input 220 Vac Frequency Hz Auxiliary Input (Aux1, Aux2) Unit Power Dissipation Max.6 watts Voltage Vac, 1 phase Frequency Hz EMI uppression Internal EMI filtering Output (F+, F-) Voltage Max. 63 input 110 Vac Quadrature Droop Input (1, 2, 3) Max. 125 input 220 Vac C 5A (1-2) or 1A (2-3) > 5VA Current Continuous 8A Max. +/- P.F +/- 0.7 Intermittent 12A for 10 sec. esistance 8 power input 110 Vac Analogue Input (A1, A2) 16 power input 220 Vac Maximum input +/- 5 Vdc Fuse pec. 5 x 20mm A (slow blow type) ensitivity +/- 25% Generator Volts (adjustable) Input resistance > 2K ohms Burden in HUN & PMG Wiring 880 power input 110 Vac Under Frequency Protection (Factory Knee Point etting) 1760 power input 220 Vac 50 Hz system presets knee point at 47 Hz 60 Hz system presets knee point at 57 Hz Voltage egulation Knee point Frequency Drift: C < +/- 0.5% ( with 4% engine governing ) Environment ypical ystem esponse Operation emperature C AV response 20 ms torage emperature C elative Humidity Max. 95% Build Up Voltage Vibration K Hz esidual voltage at AV power input terminal > 6 25 Hz Dimensions (L) x (W) x 50.0 (H) mm Voltage hermal Drift 0.03% per C change in AV ambient Weight 820 g +/- 2% AENION Carefully set the AV sensing voltage from 110 to 480 Vac using DIP witch W 4 & 5. 2

3 ECION 2 : OULINE / IZE / INALLAION EFEENCE erminal : Fast-On terminals 6.35 mm (1/4 inch) Flag erminal ( Fast-On terminal) Figure 1 Outline Drawing AENION Meggers and high-potential test equipment must not be used as it could damage the AV. 3

4 ECION 3 : DIP WICH POGAMMING & ADJUMEN ON W OFF ON 1 60Hz 50Hz W KW <90 90~500 >500 2 OFF OFF ON 3 OFF ON ON V 90~ ~ ~520 4 OFF OFF ON 5 OFF ON ON W W OFF ON 6 O/E ON O/E OFF (61) 40(50) HZ HZ 3 10 NOE For more detail about IV Generator Auxiliary Excitation Booster please visit KUAI website. 4

5 ECION 4 : WIING CONNECION PMG 200VAC max 50~500HZ (Harmoni) AUX. wires 1-2 N:5A 2-3 N:1A Figure 2 ingle & hree Phase PMG 1-2 N:5A 2-3 N:1A Figure 3 hree Phase Auxiliary Winding (Full Harmonic) N Harmoni wires AUX. wires 1-2 N:5A 2-3 N:1A 1-2 N:5A 2-3 N:1A Figure 4 Auxiliary & Harmonic Figure 5 elf-excited (HUN) 5

6 Droop % 2 1 OU2 OU1 ime ON est Output IV Fuse eady est Batt-Volt OVLD B B N:5A 2-3 N:1A Figure 6 with IV-1260 / IV-2460 AENION 1. All AC voltage readings are average value only. 2. Use a remote 500 ohms 1 watt external V for +/- 4% adjustment range. (keep shorted if not used) 3. Use a remote 1K ohms 1 watt external V for +/- 8% adjustment range. 4. If your PMG is not working you can also power the AV in shunt using terminals X1 & X2 connected to the output of the generator as long as it s less than 300 Vac. Use only the replacement fuses specified in this user manual. Appearance and specifications of products are subject to change for improvement without prior notice. 6

Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

Universal Hybrid Analog-Digital Voltage Regulator Operation Manual Universal Hybrid Analog-Digital Voltage egulator Operation Manual elf Excited Analog/Digital 5Amp AV For use in shunt and generators with auxiliary windings Warning! 1. Only qualified technicians should

More information

ADVR-053. Universal Hybrid Analog-Digital Voltage Regulator Operation Manual

ADVR-053. Universal Hybrid Analog-Digital Voltage Regulator Operation Manual ADV-053 Universal Hybrid Analog-Digital Voltage egulator Operation Manual elf Excited 5 Amp Analog / Digital Voltage egulator For shunt and auxiliary windings generators With over-excitation and lost of

More information

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator EA63-7D Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator SP POWERWORLD LTD Willows, Waterside, Ryhall, Stamford, Lincs, PE9 4EY, UK Tel: +44 1780 756872 -

More information

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual s * Use for reference purpose only and not a genuine Marathon product. 1. INTRODUCTION Sensing Input

More information

EA350. Generator Automatic Voltage Regulator Operation Manual

EA350. Generator Automatic Voltage Regulator Operation Manual Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator For General Generators Compatible with Marathon SE350* * Use for reference purpose only and not a genuine

More information

EVC300i. Generator Automatic Voltage Regulator Operation Manual

EVC300i. Generator Automatic Voltage Regulator Operation Manual EVC300i Generator Automatic Voltage Regulator Operation Manual 1. INTRODUCTION The EVC300i Voltage Regulator is thyristor base to control the DC exciter field power of conventional 50 or 60 Hz brushless

More information

EG4015. Digital Generator Governor Controller User Manual

EG4015. Digital Generator Governor Controller User Manual EG4015 Digital Generator Governor Controller User Manual Digital Governor for use in Gas and Diesel Generators with smoke and idle controls. Senses generator frequency, no magnetic pickup unit (MPU) is

More information

EVC600i. Generator Automatic Voltage Regulator Operation Manual

EVC600i. Generator Automatic Voltage Regulator Operation Manual EVC600i Generator Automatic Voltage Regulator Operation Manual 1. INTRODUCTION The EVC600i Voltage Regulator is thyristor base to control the DC exciter field power of conventional 50 or 60 Hz brushless

More information

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA BE1-59NC CAPACITOR NEUTRAL OVERVOLTAGE RELAY The BE1-59NC Capacitor Neutral Overvoltage Relay provides sensitive protection for capacitor banks. ADDITIONAL INFORMATION INSTRUCTION MANUAL ADVANTAGES Helps

More information

www. ElectricalPartManuals. com l Basler Electric VOLTAGE REGULATOR FEATURES: CLASS 300 EQUIPMENT AVC63 4 FEATURES AND APPLICATIONS

www. ElectricalPartManuals. com l Basler Electric VOLTAGE REGULATOR FEATURES: CLASS 300 EQUIPMENT AVC63 4 FEATURES AND APPLICATIONS Using enhanced technology, the AVC63-4 voltage regulator is designed for use on 50/60 Hz brushless generators. This encapsulated regulator is economical, small in size, ruggedly constructed, and incorporates

More information

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA .5 9575H Series 000 Relay Contents 9575H Series 000 Type AA, AC and DC Product Selection....................... Accessories............................ Technical Data and Specifications........... Dimensions............................

More information

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA BE1-59NC CAPACITOR NEUTRAL OVERVOLTAGE RELAY The BE1-59NC Capacitor Neutral Overvoltage Relay provides sensitive protection for capacitor banks. ADVANTAGES Helps avoid cascading capacitor failures. Sensing

More information

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1200-75 Amplifier August 2012, Rev. A LEVEL ADJUST POWER MODEL 1200 AMPLIFIER CROSS TECHNOLOGIES, INC. Data, drawings, and other material contained herein are proprietary to Cross

More information

MULTIS L72. Operating instructions

MULTIS L72. Operating instructions GB MULTIS L72 Operating instructions 2 SOCOMEC - Ref. : 876 091B ENGLISH GB Contents PRELIMINARY OPERATIONS 4 GENERAL INFORMATION 5 PRESENTATION 4 INSTALLATION 5 Mechanical environment Climatic environment

More information

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz. HVAC Farm Duty Brake 200 & 575 Volt & Controls DC 310 DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound DC & Controls 1/4-2 Hp 115/ 1 Phase 50/60 Hz. Applications: General purpose industrial use with

More information

HS-509 VIBRATION TRIP MODULE

HS-509 VIBRATION TRIP MODULE HS-509 VIBRATION TRIP MODULE 1. Overview The HS-509 is a configurable trip amplifier capable of accepting a 4-20mA signal from a HS-420 sensor and providing two trip action relay outputs along with an

More information

AF-300 E11 Adjustable Frequency Drive

AF-300 E11 Adjustable Frequency Drive AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed

More information

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive nfi Practical Demonstration of VFD Motor Speed Directly Proportional to Frequency Motor RPM= (120*F)/P Powerflex- 4M 0.4 KW= 0.5 Hp

More information

Telemetry Receiver Installation Guide

Telemetry Receiver Installation Guide BBV Telemetry Receiver Installation Guide Models covered Rx200 Building Block Video Ltd., Unit 1, Avocet Way, Diplocks Industrial Estate, Hailsham, East Sussex, UK. Tel: +44 (0)1323 842727 Fax: +44 (0)1323

More information

VAT 20 Adjustable Frequency Drive

VAT 20 Adjustable Frequency Drive VAT 0 Adjustable Frequency Drive VAT 0 Adjustable Frequency Drive The VAT 0 is a small, flexible, low cost, well performing AC drive designed for use in small machines such as fans and conveyors. The drive

More information

DPS-250AB-18 E. 電氣規格 (Electrical Specification) REV. Description Date DESCRIPTION : MODEL NO. : Date Drawn Desing(EE) Design(ME) DOCUMENT NO. : REV.

DPS-250AB-18 E. 電氣規格 (Electrical Specification) REV. Description Date DESCRIPTION : MODEL NO. : Date Drawn Desing(EE) Design(ME) DOCUMENT NO. : REV. Description Date 07/18/ 08 敖孌鳳孫占蠃杜連軍 ES-250AB-18 E S1 File Name DF-PSLA4V-2R00.DOC SHEET 1 OF 6 1. Input characteristics: 1.1 Input voltage range: 90Vac to 135Vac; 180Vac to 265Vac,single phase. switch

More information

Operating Instructions for Throttle Valves Using VRC Valve Positioner

Operating Instructions for Throttle Valves Using VRC Valve Positioner ThrottleMaster TM Operating Instructions for Throttle Valves Using VRC Valve Positioner p/n: X709116 $10.00 3/2012 Throttlemaster is a registered trademark of Vacuum Research Corporation Introduction The

More information

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.

More information

RoHS. Atma-Sphere Music Preamplifier. model P-2 OWNER'S MANUAL. Please study this document carefully before using equipment

RoHS. Atma-Sphere Music Preamplifier. model P-2 OWNER'S MANUAL. Please study this document carefully before using equipment 1742 Selby Av. St. Paul, MN 55104 651 690 2246 atma sphere.com Atma-Sphere Music Preamplifier model P-2 OWNER'S MANUAL Please study this document carefully before using equipment RoHS CONGRATULATIONS!

More information

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA) SECTION Counters & Timers (Analog / Digital) Laurel Hecon Simpson Yokogawa (YCA) Counters and Timers from the following manufacuturers are also available but not shown in catalog: Texmate Triplett (LFE)

More information

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS GENERAL DESCRIPTION The SM-1100, SM-1500 and SM-1600 Series are multi-turn, rotary actuators, designed to meet the exacting requirements for closed-loop modulating

More information

Instruction Manual Model # Block Upconverter

Instruction Manual Model # Block Upconverter Instruction Manual Model 2115-278# Block Upconverter August 2018, Rev. A MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary

More information

multi-function meters

multi-function meters multi-function meters eclipse 2 eclipse 7 installation and operating manual 1 GENERAL DESCRIPTION 2 INSTALLATION 3 WIRING INFORMATION 4 2 ECLIPSE 2 METERS 2.1 PROGRAMMING THE METER 5 2.2 INFORMATION 6

More information

SQM40/41 Actuators for air and gas dampers

SQM40/41 Actuators for air and gas dampers SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The

More information

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load

More information

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1200-07 Amplifier September 2010 Rev A MONITOR J1 LEVEL ADJUST POWER MODEL 1200 AMPLIER CROSS TECHNOLOGIES, INC. Data, drawings, and other material contained herein are proprietary

More information

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements. RoHS Lead-Solder-Exemption Compliant New 3.3 V and 5 V Output Models Universal Input 85-264 VAC Industry-Standard Footprint: 7.0" x 4.3" x 1.97" (177.8 x 109.2 x 50.0 mm) Input Transient & ESD Compliance

More information

Please take a few minutes to read this manual so that you will better understand the featues and capabilities of your MF80. MF80 Owner s Manual 1

Please take a few minutes to read this manual so that you will better understand the featues and capabilities of your MF80. MF80 Owner s Manual 1 Congratulations on your purchase of the Conrad-Johnson MF80 amplifier. You have acquired one of the finer pieces of musical reproduction equipment available today. The MF80 is the result of over a decade

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

GP-500 SERIES - Low Voltage

GP-500 SERIES - Low Voltage M O T O R & G E N E R A T O R P R O T E C T I O N AUTOMATIC INSULATION RESISTANCE TESTERS Meg-Alert is an automatic, in-line insulation resistance tester and monitor with test capabilities from 500 to

More information

Model /29S RF Splitter

Model /29S RF Splitter Instruction Manual Model 1584-29/29S RF Splitter March 2013, Rev. 0 LNB VOLTAGE A B MODEL 1584 COMBINER CROSS TECHNOLOGIES INC. GND+DC ON Data, drawings, and other material contained herein are proprietary

More information

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2 AC Voltage Range¹ / resolution 2 3 4 45 Hz to 500 Hz 1.0% + 3 500 Hz to 1 khz 2.0% + 3 600.0 mv / 0.1 mv 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V 1. All AC voltage ranges are specified

More information

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS

File E Project December 11, 2013 REPORT DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS File E322469 Project 4786125262 December 11, 2013 REPORT On DRIVERS FOR LIGHT-EMITTING DIODES ARRAYS MODULES AND CONTROLLERS Lutron Electronics Co Inc Coopersburg, Pa Copyright 2013 UL LLC UL LLC authorizes

More information

Understanding VFD. Variable Frequency Drive. nfi. nfi

Understanding VFD. Variable Frequency Drive. nfi. nfi Understanding VFD Variable Frequency Drive Practical Demonstration of VFD Delta- M Series 1.5 KW I/P: 230V 1/3 Phase O/P: 230 3 Phase VFD Status Screen Motor OFF Command Freq. Parameters Direction Amperes

More information

Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual

Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual Firmware Version: 1.0.1.8 Page 1 of 24 Dated: 23 rd June 2016 CAUTIONS: NOTE These

More information

Installation and Operating Instructions. Vari-Watt Power Controller

Installation and Operating Instructions. Vari-Watt Power Controller Installation and Operating Instructions VariWatt Power Controller PK555 003775459 October 208 VariWatt Power Controller General The Chromalox VariWatt Controller accepts an analog control signal input

More information

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Panel cutout required: 1.772 x 3.622 (45mm x 92mm) 1.76 (45mm) 2.45 (62mm) 3.20 (81mm) 3.60 (91mm) 0.59 (15mm) Special Features NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description

More information

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122 www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage

More information

POWER SUPPLIES COAX DC INSERTERS SITUATION

POWER SUPPLIES COAX DC INSERTERS SITUATION SITUATION devices require voltage on the coax output connector and RF signals must pass from input to output on the power inserter. SOLUTION Sonora power inserters couple regulated voltage on coax cables

More information

MILLITARY SPECIFICATION SHEET

MILLITARY SPECIFICATION SHEET INCH-POUND MILLITARY SPECIFICATION SHEET 10 November 2000 SUPERSEDING MIL-R-6106/14B 10 March 1989 RELAY, ELECTRIC, PERMANENT DRIVE, 50 AMP, SPDT (DB) DOUBLE MAKE DOUBLE BREAK AUXILIARY CONTACTS (5 AMP),

More information

ScopeMeter 190 Series Specifications

ScopeMeter 190 Series Specifications Seite 1 von 7 ScopeMeter 190 Series Specifications Product Home Features Specifications Models, Options & Accessories Oscilloscope Mode Meter Mode Recorder Mode General Specifications Oscilloscope Mode

More information

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data Product description 1-channel for indoor use Inbuilt for luminaires of protection class I Output current and output voltage adjustable FA output 12 V TC input channel ominal life of 50,000 h (at ta max.

More information

Instruction Manual Model BlockUpconverter

Instruction Manual Model BlockUpconverter Instruction Manual Model 2115-55 BlockUpconverter June 2009 - Rev. 0 MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary

More information

P P S - M W S C A N 1 H

P P S - M W S C A N 1 H µ-controller-systems / HARD- & SOFTWARE-DESIGN POWER-SUPPLIES FROM MILLIWATTS TO KILOWATTS Device: PPS-MWS-3000-4500-CAN1H 06 / 2017 Page 1 / 6 S w i t c h i n g M o d e P o w e r S u p p l y f o r M a

More information

TAMP6R03 (6)TRUNK AMPLIFIER

TAMP6R03 (6)TRUNK AMPLIFIER SIUAION DIRECV LNB signals need amplification to a constant level for multiple distribution locations. SOLUION Model R0 provides an automatic gain controlled output that is user adjustable from - dbm to

More information

MULTIS LMp / LMg. Systèmes de Coupure et de Protection Switching and Protection Systems

MULTIS LMp / LMg. Systèmes de Coupure et de Protection Switching and Protection Systems I MULTIS LMp / LMg F Notice d utilisation GB Operating instructions D Bedienungsanleitung NL Gebruiksaanwijzing Istruzioni per l uso SP Instrucciones de servicio P Manual de instruções Systèmes de Coupure

More information

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4 UDC100 Universal Digital Controller 51-52-03-29 11/99 Page 1 of 4 Specification Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency 1 Size SERIES 400 x SERIES x Operating distance mm 0.8 0.8 1. Housing material Connection 1) PUR cable type 1 PUR cable type 1 / Connector S8 PUR cable type 1 Degree of protection Mounting Max. switching

More information

263 Series LED Bargraph Indicator and Controllers

263 Series LED Bargraph Indicator and Controllers 263 Series LED Bargraph Process Control Water Treatment High resolution 51 segment LED Bargraph for easy reading Accuracy 1% Red display Vertical or Horizontal mounting & stackable Connection Diagrams

More information

BE3-GPR GENERATOR PROTECTIVE RELAY

BE3-GPR GENERATOR PROTECTIVE RELAY BE3-GPR GENERATOR PROTECTIVE RELAY Behind-the-Panel Mounting Semi-flush Mounting Basler Electric s BE3-GPR generator protective relay offers multiple protective features in a single package. Its microprocessor-based

More information

MAP110 AC-DC Series Data Sheet

MAP110 AC-DC Series Data Sheet Description Single-Output Model Selection VOLTAGE RANGE OUTPUT CURRENT OUTPUT CURRENT REGULATION REGULATION %p-p (NOTE 1) ACCURACY MAP110-1005 5V 4.95V to 5.50 16A 2 0.2% 1% 1% 5.09V to 5.11V MAP110-1012

More information

CLASS 300 EQUIPMENT BE3-25A AUTO-SYNCHRONIZER (Single Phase)

CLASS 300 EQUIPMENT BE3-25A AUTO-SYNCHRONIZER (Single Phase) CLASS 300 EQUIPMENT BE3-25A AUTO-SYNCHRONIZER (Single Phase) In applications requiring parallel operation of multiple generators or a single generator to an energized station bus, the BE3-25A automatically

More information

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised

SECU-16. Specifications Power: Input Voltage 9-12V DC or AC Input Current Max 200mA. 8 2-wire inputs, Analog (0 5VDC) or Supervised SECU-16 Introduction The SECU-16 module allows 8 inputs and 8 low-current relay outputs to be added to an ADICON control system. The inputs may be supervised (switch closure), analog, or 4-20mA. Specifications

More information

Process Transmitter RMA 422

Process Transmitter RMA 422 Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200

More information

Camera Control Unit 55D-BS VOLUME OPEN CABLE MIC OFF GND 2W CAMERA CABLE TALLY. Camera Adapter 55D-CA 9.39" 7.40" 5.2"

Camera Control Unit 55D-BS VOLUME OPEN CABLE MIC OFF GND 2W CAMERA CABLE TALLY. Camera Adapter 55D-CA 9.39 7.40 5.2 The Telemetrics Coax/Fiber Link is an affordable camera control system with increased operating distance. Using frequency multiplexing the following signals are transmitted over a single coaxial cable:

More information

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25 DATA SHEET Synchronisers, ANSI code 25 Synchronisation of generator to busbar Circuit breaker time compensation LED indication of status LED for activated control LED for synchronising signal 35 mm DIN

More information

Circuit-Breakers for Motor Protection Series 8523/8

Circuit-Breakers for Motor Protection Series 8523/8 > Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting

More information

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. N223 Reliance Electric s MD60 AC Drive is ready to operate out-of-the-box!

More information

SERIES 400 SERIES 620

SERIES 400 SERIES 620 x 0. 0... PUR cable type,000 Hz SERIES 00 SERIES 0 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type / Connector S,000 Hz 0,000 Hz Table Diagram ---.... 9 VDC /. ma** PUR cable type,000 Hz x

More information

AS09..S 3-pole Contactors - Spring Terminals

AS09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional

More information

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web: 2013 Catalogue BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) 473-0026 FAX. (+36-1)473-0027 e-mail: logen@logen.hu Web: http://www.logen.hu DIGITAL DIMMER LDD1225-C2 2500 Watt Per Channels DMX 512 Control Each

More information

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 2115-202 Upconverter November 2011, Rev. C MODEL 2115 UPCONVERTER CROSS TECHNOLOGIES INC. EXT 10MHZ ALARM POWER Data, drawings, and other material contained herein are proprietary

More information

1 Power Protection and Conditioning

1 Power Protection and Conditioning Power Protection and Conditioning MCR Hardwired Series Power Line Conditioning with Voltage Regulation The MCR Hardwired Series provides excellent noise filtering and surge protection to safeguard connected

More information

Integre4. Audiophile integrated amplifier. v1.2

Integre4. Audiophile integrated amplifier.   v1.2 Owner s Manual Integre4 Audiophile integrated amplifier www.lab12.gr v1.2 Table of Contents It is yours Features Unpacking and Warnings Installation & Placement Front Panel Rear Panel Connections Remote

More information

Conrad-Johnson Owner s Manual:

Conrad-Johnson Owner s Manual: Conrad-Johnson Owner s Manual: ET3 Vacuum-Tube Preamplifier conrad-johnson It just sounds right. Thank you for selecting the Conrad-Johnson ET3 Preamplifier as the control center for your audio system.

More information

Variable Speed Drives OMRON/YASKAWA F7Z - series

Variable Speed Drives OMRON/YASKAWA F7Z - series Variable Speed Drives OMRO/YASKAWA F7Z - series Short manual: F7-series with Software for Speed control of compressors with integrated compound controller PED Power Electronics Deutschland GmbH Conradtystrasse

More information

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A 72 Power Series SPDT 20 A; DPDT 15 A UL listed when used with proper Magnecraft sockets The 72 Plug-in Power relays offer clear or full-feature covers with multiple mounting options and accessories. Feature

More information

High performance circuit breakers

High performance circuit breakers Series High performance Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific trip characteristics

More information

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web: 2016 Catalogue BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) 473-0026 FAX. (+36-1)473-0027 e-mail: logen@logen.hu Web: http://www.logen.hu DIGITAL DIMMER LDD1225-C2 2500 Watt Per Channels DMX 512 Control Each

More information

Owner s Manual MIGHTY. Class A Single Ended Power Amplifier

Owner s Manual MIGHTY.   Class A Single Ended Power Amplifier Owner s Manual MIGHTY Class A Single Ended Power Amplifier www.lab12.gr Table of Contents It is yours Features Installation & Placement Front Panel Rear Panel Main connections For the safety of your equipment

More information

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630) Vorne Industries 87/719 Analog Input Module User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Introduction... 1.1 Accessing Wiring Connections

More information

Ordering details. Approval. Classification

Ordering details. Approval. Classification Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation

More information

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap Description: The TR5000 is a Full Logic Control Process ratemeter that can display up to three separate values of rate and compare them to programmable set points. Rates A & B can be programmed by the

More information

Single-Output 2000 W

Single-Output 2000 W Single-Output 2000 W 6571A-6575A Front panel and analog control of output voltage and current Fast, low-noise outputs Fan-speed control to minimize acoustic noise Protection features to ensure DUT safety

More information

DCP100 Digital Control Programmer Specifications

DCP100 Digital Control Programmer Specifications DCP100 Digital Control Programmer Specifications EN01-6028 October 1996 Overview The DCP100 is a microprocessor based 1 /4 DIN programmer/controller for process variable versus time control of temperature,

More information

LAMM INDUSTRIES, INC.

LAMM INDUSTRIES, INC. LAMM INDUSTRIES, INC. TheLP1Si gnat ur e phono preamplifier LAMM INDUSTRIES, INC. LP1 Signature dual monaural phono preamplifier The dual monaural phono preamplifier model LP1 Signature is the ultimate

More information

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O Characteristics motion servo drive - Lexium 23 - single phase 200...255 V - 1 kw - I/O Main Range of product Product or component type Device short name Complementary Format of the drive Network number

More information

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control

More information

Gateway 46-inch Plasma TV Specifications

Gateway 46-inch Plasma TV Specifications Gateway 46-inch Plasma TV Specifications Specifications are subject to change without notice or obligation. Display Panel Screen size Aspect ratio Number of pixels Pixel Pitch Luminance Diagonal 46-inch

More information

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS Standard Configuration Vertical Mount Option FEATURES Antenna mount, weatherproof to IP-65 Automatic 5/10 MHz internal/external

More information

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display AP-34 Separate Amplifier Type Sensor Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display Description Industry's smallest & lightest

More information

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz Mobile Communications MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO

More information

SPECIFICATION ESD FSP500-80MPD. Released Date:2015/07/27-14:41:38

SPECIFICATION ESD FSP500-80MPD. Released Date:2015/07/27-14:41:38 SPECIFICATION ESD14050296 FSP500-80MPD Released Date:2015/07/27-14:41:38 1/9 禁止翻印外洩 All rights reserved ESD14050296-R3.pdf 檔案建立時間 :2015/7/27 2:41 下午 SPECIFICATION FSP500-80MPD Main Feature: Active PFC

More information

Description Diagram Page

Description Diagram Page notiziario tecnico 2004 SISTEMA VIDEO 4+n installation wiring diagrams VIDEO SYSTEM 4+n INDEX: Description Diagram Page Section of wires 2/UK Suggestions for the correct installation 3/UK Terminal functions

More information

High Performance Outdoor Test Translators

High Performance Outdoor Test Translators Input Output LO Frequency Frequency Frequency Model (GHz) (GHz) (GHz) Number RF Transmit-Band to RF Receive-Band 5.85 6.425 3.625 4.2 2.225 DN-WS-6.1/3.9 5.85 6.65 3.4 4.2 2.45 DN-WS-6.25/3.8 6.725 7.025

More information

Operating instructions Electronic preset counter Type series 717

Operating instructions Electronic preset counter Type series 717 Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range

More information

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS FEATURES Small weather resistant enclosure Automatic 5/10 MHz internal/external reference selection 10/100 Base-T Ethernet and RS-485/RS-422 remote control

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

ECA series. Encapsulated 5W - 30W. 5, 10, 15 and 30W Ultraminiature Encapsulated Switching Power Supplies. Universal VAC Input.

ECA series. Encapsulated 5W - 30W. 5, 10, 15 and 30W Ultraminiature Encapsulated Switching Power Supplies. Universal VAC Input. Universal 90-264VAC Input High Efficiency Improved EMI Performance 3000V Isolation Single and Dual Outputs As Small as 2.28 x 1.77 x 0.83 Number Output Voltage Output Amps(max) (pk) SINGLE OUTPUT - PCB

More information

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011 RD - 122 RACK MOUNT DIMMER OWNERS MANUAL VERSION 1.3 03/09/2011 Page 2 of 14 TABLE OF CONTENTS UNIT DESCRIPTION AND FUNCTIONS 3 POWER REQUIREMENTS 3 INSTALLATION 3 PLACEMENT 3 POWER CONNECTIONS 3 OUTPUT

More information

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature

More information

J R Sky, Inc. tel: fax:

J R Sky, Inc.  tel: fax: STEREO OPTICAL RECORDING SYSTEM N UOPTIX STEREO OPTICAL RECORDING MONITOR LEFT SYSTEM MODE PREVIEW RECORD BIAS RECORD REV SETUP TEST RIGHT INPUT SETUP INPUT BIAS SETUP BIAS INPUT STEREO AUX MONO DIRECT

More information