Start display at page:

Download "MIKRO POWER FACTOR CORRECTION COMPONENTS"

Transcription

1

2

3 MIKRO POWER FACTOR CORRECTION COMPONENTS MIKRO POWER FACTOR REGULATOR Steps 6, 8, 12, 14 Voltage 1 4V AC Frequency 0 and 60 Hz Detection method Displacement Power Factor Input current A Modes Automatic, rotational, 4 quadrant, manual and linear C/K Manual setting and auto detect Mounting Panel MIKRO POWER FACTOR CORRECTION CAPACITOR Type Power Voltage range Temperature class LOSSES -Capacitor losses -Total losses with discharge resistor Case IP Dry Type 2. kvar to 60 kvar 2 to 690 V AC D max. temp C max. mean 24h = 4 C max. mean 1 year = 3 C lowest temperature = - 2 C <0.3 W/kvar <1.0 W/kvar Aluminium cylinder IP 00 (terminal cover for higher degree of protection class) Oil Type kvar to 7 kvar 2 to 660 V AC max. temp 4 C max. mean 24hr = 3 C max. mean 1 year = 2 C lowest temperature = -2 C <0.3 W/kvar <1.0 W/kvar Steel IP 00 (terminal cover for higher degree of protection class) Impregnation Standard Safety Epoxy resin IEC , IEC Self healing technology Overpressure disconnector Capacitor Oil (Non PC) IEC , IEC Self healing technology Overpressure disconnector MIKRO DETUNED REACTOR Voltage 380 4V AC Output power 4 0kvar Frequency 0 or 60 Hz Detuning/Filtering %p 6, 7, 14%* 13 PRODUCT CATALOGUE 2

4 MIKRO POWER FACTOR REGULATOR The power factor regulator combines comprehensive operations with user-friendly control settings. It uses numerical techniques to compute the phase difference between the fundamentals of current and voltage, enabling precise power factor measurement even in the presence of harmonics. FEATURES APPLICATIONS Detect and correct displacement power factor due to inductive loads. 1 Microprocessor based intelligent auto switching control 2 Automatic C/K and rated step adjustment 3 User friendly settings 4 Complies with IEC standard Complies with IEC standard 6 2 Inch, 64 x 128 dot matrix LCD display with back lighting* 7 Three phase and single phase detection of reactive power* 8 Three phase compensation mode* 9 Measurement parameters* - Active, reactive, apparent power - Temperature - Phase voltage and phase current - Frequency - Up till 31st order Harmonics measurement in graphical and table format - Power Factor and Displacement Power Factor (Cos Ø) Modus-RTU communication* *Only applicable to PFRLCD CATALOGUE 13PRODUCT 3

5 MIKRO POWER FACTOR REGULATOR TYPICAL APPLICATION DIAGRAM PFRLCD X80 L1 L2 L3 N N L1 L2 L3 In Out In Out In Out N L CT1 CT2 CT3 AUX P+ GND T1 T2 Thermistor N- RP RS48 Modbus-RTU P1 P2 P1 P2 P1 PFR LCD P2 FAN SIG FUSE SIG FAN FUSE K12 K2 K1 LOAD PFR 1 / 1 / 80 / 60 MAIN N L3 L2 L1 FUSE P1 P ~4 V AC AUX VOLTAGE CURRENT / A Power Factor Regulator ~2 V AC AUX VOLTAGE For 2~2V AC Model Only FUSE K14 K13 K2 K1 LOAD 13 PRODUCT CATALOGUE 4

6 MIKRO POWER FACTOR REGULATOR TYPICAL APPLICATION DIAGRAM PFR 96 MAIN N L3 L2 L1 FUSE P1 P VOLTAGE 2~2 V AC / 1~1 V AC CURRENT / A Power Factor Regulator FUSE K1 K K6 LOAD Diagram 1 - For model PFR96 PFR 96P MAIN N L3 L2 L1 FUSE P1 P VOLTAGE 380~4 V AC / CURRENT / A Power Factor Regulator FUSE K1 K K6 LOAD Diagram 2 - For model PFR96P 13 PRODUCT CATALOGUE

7 MIKRO POWER FACTOR REGULATOR ORDERING INFORMATION PFR LCD X80 PFRLCD1P3-2-0 PFRLCD80P3-2-0 PFRLCD1P1-2-0 PFRLCD80P1-2-0 PFRLCD1P PFRLCD80P PFRLCD1P Step, 3 Phase, 8~26V AC, 0Hz 8 Step, 3 Phase, 8~26V AC, 0Hz 12 Step, 1 Phase, 8~26V AC, 0Hz 8 Step, 1 Phase, 8~26V AC, 0Hz 12 Step, 3 Phase, 8~26V AC, 60Hz 8 Step, 3 Phase, 8~26V AC, 60Hz 12 Step, 1 Phase, 8~26V AC, 60Hz PFR 1 / 1 / 80 / 60 PFR Steps, 0 Hz system, auxiliary voltage 380~4V AC PFR Steps, 0 Hz system, auxiliary voltage 380~4V AC PFR Steps, 0 Hz system, auxiliary voltage 380~4V AC PFR Steps, 0 Hz system, auxiliary voltage 380~4V AC PFR Steps, 0 Hz system, auxiliary voltage 2~2V AC PFR Steps, 0 Hz system, auxiliary voltage 2~2V AC PFR Steps, 0 Hz system, auxiliary voltage 2~2V AC PFR Steps, 0 Hz system, auxiliary voltage 2~2V AC PFR Steps, 60 Hz system, auxiliary voltage 380~4V AC PFR Steps, 60 Hz system, auxiliary voltage 380~4V AC PFR Steps, 60 Hz system, auxiliary voltage 380~4V AC PFR Steps, 60 Hz system, auxiliary voltage 380~4V AC PFR Steps, 60 Hz system, auxiliary voltage 2~2V AC PFR Steps, 60 Hz system, auxiliary voltage 2~2V AC PFR Steps, 60 Hz system, auxiliary voltage 2~2V AC PFR Steps, 60 Hz system, auxiliary voltage 2~2V AC PFR LCD X80 PFR PFR PFR PFR PFR96P PFR96P Steps, for 0 Hz system, auxiliary voltage 2~2V AC 6 Steps, for 60 Hz system, auxiliary voltage 2~2V AC 6 Steps, for 0 Hz system, auxiliary voltage 1~1V AC 6 Steps, for 60 Hz system, auxiliary voltage 1~1V AC 6 Steps, for 0 Hz system, auxiliary voltage 380~4V AC 6 Steps, for 60 Hz system, auxiliary voltage 380~4V AC 13 PRODUCT CATALOGUE 6

8 MIKRO POWER FACTOR REGULATOR CASE DIMENSIONS PFR LCD X80 144mm 122mm 2mm 138mm 144mm MIKRO 138mm Front View Side View Panel Cutout PFR 1 / 1 / 80 / mm 90mm 76mm 138mm 144mm 138mm PFR 96P Front View Side View Panel Cutout PFR 96 / PFR96P 96mm 90mm 70mm 91mm 96mm 91 mm Front View Side View Panel Cutout 13 PRODUCT CATALOGUE 7

9 LOW VOLTAGE POWER CAPACITOR Mikro's capacitors are designed for power factor correction in low voltage applications such as motors, transformers, generators and supply cables. The capacitors are manufactured using metallised polypropylene film as the dielectric. The dry type capacitor operates within a cylindrical aluminium case which improves the thermal response and simplifies installation. FEATURES APPLICATIONS Used for both single phase and 3 phase, depending on the design on the user for power factor improvement values. Appropriate for use in industry and general use. 1 General industrial use 2 Improves power factor 3 Reduces line losses 4 Decreases voltage drop Saves energy 6 Metalised Prolypropylene film which has low losses 7 Compact design 8 Dry type aluminum cylinder 9 Oil type steel case Self healing Technology 11 Overpressure disconnector 12 Discharge and bleeding resistor included 13 Vertical and horizontal mounting position 14 Adhere to IEC and IEC standards Long life CATALOGUE 13PRODUCT 8

10 LOW VOLTAGE POWER CAPACITOR TECHNICAL SPECIFICATION Type Voltage Range Frequency Power Range Capacitor Losses Total Losses with Discharge Resistor Capacity Tolerance Max Overvoltage Max Overcurrent Withstand Voltage Connection Insulation Level Dielectric Ambient Temp Discharge Cooling Impregnation Safety Installation Place Applicable Standards Dry Type (Cylinder type) V AC 0Hz or 60Hz 2.kvar to 0kvar < 0.3 W/kvar < 1.0 W/kvar -% ~ % (at ºC) Un + % (up to 8 hours daily) Un + % (up to mins daily) Un + % (up to mins monthly) Un + % (up to 1 mins monthly) 1.3 x In 2. x Un ( seconds) 3 phase (Single phase on request) 3/kV Metallised Polypropylene -2ºC ~ ºC External discharge module Natural forced Epoxy resin Self healing technology Overpressure disconnector Indoor (Outdoor on request) IEC , IEC Oil Type V AC 0Hz or 60Hz 2.kvar to 0kvar < 0.3 W/kvar < 1.0 W/kvar -% ~ % (at ºC) Un + % (up to 8 hours daily) Un + % (up to mins daily) Un + % (up to mins monthly) Un + % (up to 1 mins monthly) 1.3 x In 2. x Un ( seconds) 3 phase (Single phase on request) 3/kV Metallised Polypropylene -2ºC ~ ºC External discharge module Natural forced Capacitor Oil (Non PC) Self healing technology Overpressure disconnector Indoor (Outdoor on request) IEC , IC PRODUCT CATALOGUE 9

11 LOW VOLTAGE POWER CAPACITOR ORDERING INFORMATION Part No. Rated (kvar) Cn (uf) Current In (Amp) Dimensions D*H (mm.) Stud Screw DRY TYPE CAPACITOR CYLINDER (1 PHASE, 0Hz, 20V AC) MKC-200KS *1 MKC-207KS MKC-20KS MKC-212KS *2 MKC-20KS *2 MKC-20KS *27 DRY TYPE CAPACITOR CYLINDER (3 PHASE, 60Hz, 2V AC) MKC-22602KT *13 MKC-22600KT * MKC-22607KT MKC-2260KT MKC-22612KT *27 MKC-2260KT * MKC-2260KT *27 MKC-22620KT * MKC-226KT * DRY TYPE CAPACITOR CYLINDER (3 PHASE, 0Hz, 2V AC) MKC-22KT *16 MKC-20KT * MKC-27KT MKC-2KT *27 MKC-2312KT *27 MKC-2KT *27 MKC-2KT * MKC-2320KT * MKC-23KT * 13 PRODUCT CATALOGUE

12 LOW VOLTAGE POWER CAPACITOR ORDERING INFORMATION Part No. Rated (kvar) Cn (uf) Current In (Amp) Dimensions D*H (mm.) Stud Screw DRY TYPE CAPACITOR CYLINDER (3 PHASE, 0Hz, 380V AC) MKC-3802KT *13 MKC-3800KT *1 MKC-3807KT * MKC-380KT MKC-3812KT MKC-380KT *27 MKC-380KT *27 MKC-3820KT *27 MKC-38KT *280 MKC-380KT *280 MKC-3800KT *3 DRY TYPE CAPACITOR CYLINDER (3 PHASE, 0Hz, 0V AC) MKC-02KT *13 MKC-00KT *1 MKC-07KT * MKC-0KT MKC-12KT MKC-0KT *27 MKC-0KT *27 MKC-20KT *27 MKC-KT * MKC-0KT * MKC-00KT * PRODUCT CATALOGUE 11

13 LOW VOLTAGE POWER CAPACITOR ORDERING INFORMATION Part No. Rated (kvar) Cn (uf) Current In (Amp) Dimensions D*H (mm.) Stud Screw DRY TYPE CAPACITOR CYLINDER (3 PHASE, 0Hz, 4V AC) MKC-2KT *13 MKC-0KT *16 MKC-7KT * MKC-KT MKC-412KT MKC-KT *27 MKC-KT *27 MKC-420KT *27 MKC-4KT * MKC-40KT * MKC-0KT *380 DRY TYPE CAPACITOR CYLINDER (3 PHASE, 0Hz, 4V AC) MKC-02KT *13 MKC-00KT *16 MKC-07KT * MKC-0KT * MKC-12KT MKC-0KT MKC-0KT *27 MKC-20KT *27 MKC-KT *27 MKC-0KT * MKC-00KT * 13 PRODUCT CATALOGUE 12

14 LOW VOLTAGE POWER CAPACITOR ORDERING INFORMATION Part No. Rated (kvar) Cn (uf) Current In (Amp) Dimensions D*H (mm.) Stud Screw DRY TYPE CAPACITOR CYLINDER (3 PHASE, 0Hz, 480V AC) MKC-4802KT *13 MKC-4800KT *1 MKC-4807KT * MKC-480KT MKC-4812KT MKC-480KT *27 MKC-480KT *27 MKC-4820KT *27 MKC-48KT *27 MKC-480KT *280 MKC-4800KT *3 DRY TYPE CAPACITOR CYLINDER (3 PHASE, 0Hz, 2V AC) MKC-202KT *13 MKC-200KT *1 MKC-207KT * MKC-20KT MKC-212KT MKC-20KT *27 MKC-20KT *27 MKC-220KT *27 MKC-2KT *27 MKC-20KT *280 MKC-200KT *3 13 PRODUCT CATALOGUE 13

15 LOW VOLTAGE POWER CAPACITOR ORDERING INFORMATION Part No. Rated (kvar) Cn (uf) Current In (Amp) Dimensions D*H (mm.) Stud Screw DRY TYPE CAPACITOR CYLINDER (3 PHASE, 0Hz, 660V AC) MKC-660KT MKC-660KT *27 MKC-660KT *27 MKC-6620KT *27 MKC-66KT *27 MKC-660KT * MKC-6600KT *380 MKC-66600KT *380 DRY TYPE CAPACITOR CYLINDER (3 PHASE, 0Hz, 690V AC) MKC-6900KT *16 MKC-6907KT * MKC-690KT MKC-6912KT MKC-690KT *27 MKC-690KT *27 MKC-6920KT *27 MKC-69KT *27 MKC-690KT * MKC-6900KT * 13 PRODUCT CATALOGUE 14

16 LOW VOLTAGE POWER CAPACITOR ORDERING INFORMATION Part No. Rated (kvar) Cn (uf) Current In (Amp) Dimensions D*H (mm.) OIL TYPE CAPACITOR (3 PHASE 0 Hz, 2V AC) MMS-2KT * MM-2KT * MM-2KT *180 MM-22KT *2 MM-2KT *2 MM-2KT *3 MM-20KT *360 OIL TYPE CAPACITOR (3 PHASE 0 Hz, 4V AC) MMM-0KT *16 MMS-07KT *1 MMS-KT * MMS-12KT * MMS-KT * MMS-KT *2 MM-2KT *180 MM-KT *2 MM-KT *2 MM-0KT *290 OIL TYPE CAPACITOR (3 PHASE 0 Hz, 4V AC) MMS-4KT * MMS-4KT * MMS-4KT *2 MM-42KT *180 MM-4KT *190 MM-4KT *2 MM-40KT * PRODUCT CATALOGUE

17 LOW VOLTAGE POWER CAPACITOR ORDERING INFORMATION Part No. Rated (kvar) Cn (uf) Current In (Amp) Dimensions D*H (mm.) OIL TYPE CAPACITOR (3 PHASE 0 Hz, 2V AC) MMS-200KT *1 MMS-20KT *17 MMS-2012KT * MMS-20KT *2 MM-20KT * MM-202KT *180 MM-20KT *2 MM-20KT *280 MM-200KT *3 OIL TYPE CAPACITOR (3 PHASE 0 Hz, 660V AC) MMS-660KT * MMS-660KT * MMS-660KT *2 MM-6602KT *180 MM-660KT *2 MM-660KT *2 MM-6600KT *290 MM-66060KT * MM-6607KT *4 13 PRODUCT CATALOGUE 16

18 LOW VOLTAGE POWER CAPACITOR CASE DIMENSIONS DRY TYPE CAPACITOR D=3 3 +_ _ 2 +_ 2 Name Plate H +_ Name Plate H +_ 3 Stud Screw Stud Screw 13 PRODUCT CATALOGUE 17

19 LOW VOLTAGE POWER CAPACITOR CASE DIMENSIONS OIL TYPE CAPACITOR Max Torque 1.Nm MMM Series 13 PRODUCT CATALOGUE 18

20 LOW VOLTAGE POWER CAPACITOR CASE DIMENSIONS OIL TYPE CAPACITOR MMS Series 13 PRODUCT CATALOGUE 19

21 LOW VOLTAGE POWER CAPACITOR CASE DIMENSIONS OIL TYPE CAPACITOR MM Series 13 PRODUCT CATALOGUE

22 MIKRO DETUNED REACTOR Modern electronic power apparatus such as drives and uninterruptable power supplies produce nonlinear current which in turn introduces line pollution into networks in the form of harmonics. When these harmonics interacts with power factor correction capacitors and the inductance of the feeder transformer, a resonance phenomenon occurs. The resonance phenomenon causes excessive voltage and current that is detrimental to the power factor capacitors. Mikro s Antiresonance Reactor detunes the circuit from forming the resonance phenomenon while still providing power factor correction. FEATURES 1 Avoids resonance conditions 2 Reduces harmonic distortion 3 Reduces power losses 4 High harmonic load capacity Leads to low losses 6 Has a high linearity to avoid choke tilt 7 Convenient mounting points APPLICATIONS 8 Long expected lifespan Detuned harmonic filters. 9 Temperature protection CATALOGUE 13PRODUCT 21

23 MIKRO DETUNED REACTOR TECHNICAL SPECIFICATION Frequency 0Hz or 60Hz Voltage V AC Output power 4..0kvar * Detuning/Filtering %p 6, 7, 14% *** Core Multi Gap Silicon Steel Iron Core Ambient Temperature C Max, Class D Insulation Class H Insulation Strength 3kV 0Hz for 1 min P-P, P-E Linearity < % drop of initial inductance value * Approval IEC Ed 1.0 ** Cooling Natural Cooling Enclosure IP00 Phase 3 Phase Temperature protection i-metal thermostat, 0 C NC type ***.67 and 13% available upon request ** Applicable to certain model * Able to customize 13 PRODUCT CATALOGUE 22

24 MIKRO DETUNED REACTOR ORDERING INFORMATION For p= 6, 7 & 14% reactor, with 2V AC 0Hz capacitor at 4 V AC 0Hz only Capacitor Ucr 2V AC Ith P = Pw (Ic) A C D E H- holes Wt A A A P/No: Qcr kvar Amp % Watt mm mm mm mm mm mm kg type %P-Un/Qc_Ucr/Qcr MX07-4/3.4-2/00 MX07-4/6.7-2/0 MX07-4/.1-2/0 MX07-4/13.4-2/0 MX07-4/16.8-2/02 MX07-4/.2-2/0 MX07-4/26.9-2/0 MX07-4/33.6-2/00 MX07-4/.3-2/060 MX07-4/3.8-2/080 MX07-4/67.2-2/0 MX07-4/80.6-2/1 MX07-4/0.8-2/0 MX07-4/ / % MX13-4/18.0-2/ % MX13-4/21.6-2/ % MX13-4/28.7-2/0 0 14% MX13-4/3.9-2/ % MX13-4/43.1-2/ % MX13-4/7.-2/ % MX13-4/71.8-2/ % MX13-4/86.2-2/1 13 PRODUCT CATALOGUE 23

25 MIKRO DETUNED REACTOR ORDERING INFORMATION For p= 6, 7 & 14% reactor, with 2V AC 0Hz capacitor at 4 V AC 0Hz only Capacitor Ucr 2V AC Ith P = Pw (Ic) A C D E H- holes Wt A A P/No: Qcr kvar Amp % Watt mm mm mm mm mm mm kg type %P-Un/Qc_Ucr/Qcr 6% 6% 6% 6% 6% 6% 6% 6% 6% 6% 6% 6% MX06-4/6.7-2/0 MX06-4/.0-2/0 MX06-4/13.3-2/0 MX06-4/16.6-2/02 MX06-4/19.9-2/0 MX06-4/26.6-2/0 MX06-4/33.2-2/00 MX06-4/.0-2/060 MX06-4/3.2-2/080 MX06-4/66.-2/0 MX06-4/79.8-2/1 MX06-4/99.7-2/0 13 PRODUCT CATALOGUE 24

26 MIKRO DETUNED REACTOR ORDERING INFORMATION For p= reactor, with 4V AC 0Hz capacitor at 380-0V AC 0Hz only Capacitor Ucr 2V AC Ith P = Pw (Ic) A C D E H- holes Wt A A P/No: Qcr kvar Amp % Watt mm mm mm mm mm mm kg type %P-Un/Qc_Ucr/Qcr MX07-0/4.4-4/00 MX07-0/8.9-4/0 MX07-0/13.3-4/0 MX07-0/17.8-4/0 MX07-0/22.2-4/02 MX07-0/2.0-4/028 MX07-0/26.7-4/0 MX07-0/3.6-4/0 MX07-0/44.4-4/00 MX07-0/0.0-4/06 MX07-0/3.3-4/060 MX07-0/66.7-4/07 MX07-0/71.1-4/080 MX07-0/7.0-4/084 MX07-0/88.9-4/0 MX07-0/0.0-4/112 MX07-0/6.6-4/1 MX07-0/ /12 MX07-0/ /0 MX07-0/ / 13 PRODUCT CATALOGUE 2

27 MIKRO DETUNED REACTOR ORDERING INFORMATION For p= reactor, with 2V AC 0Hz capacitor at 380-0V AC 0Hz only Capacitor Ucr 2V AC Ith P = Pw (Ic) A C D E H- holes Wt A A P/No: Qcr kvar Amp % Watt mm mm mm mm mm mm kg type %P-Un/Qc_Ucr/Qcr MX07-0/6.2-2/0 MX /0 MX07-0/12.-2/0 MX07-0/.6-2/02 MX07-0/18.7-2/0 MX07-0/2.0-2/0 MX07-0/31.2-2/00 MX07-0/37.-2/060 MX07-0/46.8-2/07 MX07-0/49.9-2/080 MX07-0/62.4-2/0 MX07-0/7.0-2/1 MX07-0/78.0-2/12 MX07-0/93.6-2/0 MX07-0/99.9-2/ MX07-0/ /0 13 PRODUCT CATALOGUE 26

28 MIKRO DETUNED REACTOR DIMENSIONS C Terminal locks C Copper us ar Connection A A D H E D H E Vertical Mount: Type A Vertical Mount: Type Copper us ar Connection C A E H D Vertical Mount: Type C Please see the Ordering Information for the Dimension A to H. 13 PRODUCT CATALOGUE 27

29 Mikrocap Sdn. hd. (98192-T) No.1 Jalan TP 7/7, Sime UEP Industrial Park, 0 Shah Alam, Selangor, Malaysia. Tel : Fax : sales@itmikro.com

Capacitors and banks 50 Hz 0 400/415 V network voltage

Capacitors and banks 50 Hz 0 400/415 V network voltage Capacitors and anks 50 Hz 0 Varplus M capacitors 051327 E92427 E92428 E89596 E89598 The range of Varplus M modular capacitors consists of the Varplus M1 and Varplus M4 capacitors, whose different assemly

More information

POWER FACTOR CORRECTION

POWER FACTOR CORRECTION Main Catalogue 2015 POWER FACTOR CORRECTION POWER QUALITY ENERGY MANAGEMENT FRAKO Leading-edge quality for reliable power supply networks FRAKO's mission is to provide solutions that are designed and

More information

R.2. Power capacitors, LV. Power factor correction and harmonic filtering. Homepage : Circutor-NRW Büro Köln

R.2. Power capacitors, LV. Power factor correction and harmonic filtering. Homepage :  Circutor-NRW Büro Köln R.2 Power factor correction and harmonic filtering Power capacitors, LV Mail: Hberk@circutor-nrw.de Homepage : www.berk-iv.de Kontakt: Berk Industrievertretung 51103 Köln Erna Schaeffler Stra.1a Tel: 00492205910003

More information

Power Factor Correction Power Quality Solutions

Power Factor Correction Power Quality Solutions EPCOS Product Profile 2016 Power Factor Correction Power Quality Solutions www.epcos.com Contents Power Quality Solutions Preview 3 PFC capacitor series overview 6 PQS key components overview 8 Important

More information

Power Factor Correction Power Quality Solutions

Power Factor Correction Power Quality Solutions EPCOS Product Profile 2013 Power Factor Correction Power Quality Solutions www.epcos.com Contents Power Quality Solutions Preview 3 PFC capacitor series overview 6 PQS key components overview 8 Important

More information

APQ Series Type C Power Factor Correction Banks

APQ Series Type C Power Factor Correction Banks APQ Series Type C Power Factor Correction Banks N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Regardless of the load size or type, APQ will work

More information

Series CT7N Bimetallic Overload Relays

Series CT7N Bimetallic Overload Relays Series CT7N imetallic Overload Relays Choose CT7N overloads in DC applications and when monitoring Variable Frequency Drives Sprecher + Schuh has always paid particular attention to the subject of motor

More information

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40 Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,

More information

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction Series/Type: Ordering code: Date: November 2010 Version: 4 entered in headers and footers! Please fill in the Film Capacitors Power Factor Correction Identification/Classification 2 (header 2 + bottom

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 DATASHEET - NZMC1-A160 Circuit-breaker, 3p, 160A Part no. NZMC1-A160 Catalog No. 283296 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection

More information

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction Series/Type: Ordering code: Date: January 2018 Version: 9 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the

More information

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.

More information

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Deliveryprogramme Circuitbr.,3pmotorprotection Partno. Articleno. 265784 NZMN4-ME875 Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation type Fixed Release

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A Deliveryprogramme Circuitbreak.3pselect.protection Partno. Articleno. 265777 NZMH4-VE1600 Product range Circuit-breaker Protective function Systems, cable, selectivity and generator protection Standard/Approval

More information

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

AS09..S 3-pole Contactors - Spring Terminals

AS09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp AS09..S 3-pole Contactors - Spring AC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Rail-mounted, no tools required, - Additional

More information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100 DATASHEET - NZMN3-4-AE400 Circuit-breaker, 4p, 400A Part no. NZMN3-4-AE400 Catalog No. 265891 Similar to illustration EL-Nummer (Norway) 0004358857 Delivery program Product range Circuit-breaker Protective

More information

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286 CI-TI TM Contactors and Motor Starters June 2002 DKACT.PD.C00.I2.02 520B1286 Introduction are intended for a.c. coil voltages and cover the power range 45-238 kw. The largest types, CI 170 EI-420 EI have

More information

Power factor solutions for electric switchboards

Power factor solutions for electric switchboards Power factor solutions for electric switchboards DO IT YOURSELF Technology for energy efficiency Your global partner Viladecavalls (Barcelona - Spain) With a successful trajectory of over 35 years in the

More information

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A DATASHEET - NZMN3-VE630 Circuit-breaker, 3p, 630A Part no. NZMN3-VE630 Catalog No. 259133 EL-Nummer (Norway) 0004358791 Similar to illustration Delivery program Product range Circuit-breaker Protective

More information

Modular pulse operated latching relay 16 A

Modular pulse operated latching relay 16 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 DATASHEET - NZMH2-A100 Circuit-breaker, 3p, 100A Part no. NZMH2-A100 Catalog No. 259099 Similar to illustration Delivery program Product range Circuit-breaker Protective function System and cable protection

More information

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output Driver LC 10W 350mA fixc lp SNC2 ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 350 ma Max. output power 10.2 W Up to 80 % efficiency For

More information

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil Product data sheet Characteristics LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil Product data sheet Characteristics LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Generator protection relay

Generator protection relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Off-the-shelf generator protection relay for small and medium sized power generators Three-phase time overcurrent and

More information

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122 www.stahl.de with 3 Main Contacts and max. 4 Auxiliary Contacts > Screw fastening version robust vibration resistant reliable > Corrosion resistant enclosure material > Easily accessible connection terminals

More information

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Bimetal Temperature Switch

Bimetal Temperature Switch Phone: +44 19 635533 Fax: +44 19 635262 Data sheet 608301 Page 1/8 Bimetal Temperature Switch Special features Electromechanical temperature switch with a fixed switching temperature Protection type IP52,

More information

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL Obsolete Overload Cross Reference Series CT7/CT7K to Cross Reference CT7 CT7K Directly Mounts to Contactor... Adjustment Catalog Adjustment Catalog Adjustment Catalog Code Code Range (A) Number Range (A)

More information

Altman Lighting Spectra Cyc 50 Specification

Altman Lighting Spectra Cyc 50 Specification 1.01 CYCLORAMA LIGHTING A. General 1. The fixture shall be a compact, lightweight color-mixing LED asymmetrical wash fixture with 8 or 16 bit DMX control of intensity and color. The fixture shall be the

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 45W 1050mA fixc C SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 1,050 ma output power 45 W Nominal life-time up to 50,000

More information

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 25A power contactors silent CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning - Connection...

More information

Immersion Pumps HCT (High Chem) sealless

Immersion Pumps HCT (High Chem) sealless Immersion Pumps HCT (High Chem) sealless 1-6004-US Centrifugal pumps of plastic for a wide variety of industrial fluids Technical data Delivery rate Q max = 120 l/min Delivery head H max = 32 m Temperature

More information

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements. RoHS Lead-Solder-Exemption Compliant New 3.3 V and 5 V Output Models Universal Input 85-264 VAC Industry-Standard Footprint: 7.0" x 4.3" x 1.97" (177.8 x 109.2 x 50.0 mm) Input Transient & ESD Compliance

More information

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) * EE-SX/6 Photomicrosensor with 0- to 00-mA direct switching capacity for built-in application. Series includes models that

More information

Power factor solutions for electric switchboards

Power factor solutions for electric switchboards Power factor solutions for electric switchboards DO IT YOURSELF Technology for energy efficiency Your global partner Viladecavalls (Barcelona - Spain) With a successful trajectory of over 35 years in the

More information

Panel-mounting thermostats, type series EM

Panel-mounting thermostats, type series EM Data sheet 602025 Page /5 Panel-mounting thermostats, type series EM Particularities Operating temperature limiter Limit value range up to +650 C with temperature compensation Brief description Panel-mounting

More information

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 40W 900mA fixc C SNC ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 900 ma Max. output power 40 W Nominal life-time up to 50,000

More information

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics Operating Instructions 07/2007 Edition SINAMICS G130/G150 Line harmonics filter sinamics s Safety information 1 General 2 SINAMICS SINAMICS G130/G150 Operating Instructions Mechanical installation 3 Electrical

More information

Linear flow control with actuator IFC

Linear flow control with actuator IFC Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20

More information

MXB GENERATOR SERIES kva - 50 Hz V 12,5-200 kva - 60 Hz V

MXB GENERATOR SERIES kva - 50 Hz V 12,5-200 kva - 60 Hz V MXB GENERATOR SERIES 10-160 kva - 50 Hz - 400 V 12,5-200 kva - 60 Hz - 480 V STANDARD CONFIGURATION Main components 160 180 225 Magnetic steel Housing Shield Shaft Fan Terminal board Low losses. Insulated

More information

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

PRINCIPLES AND APPLICATIONS

PRINCIPLES AND APPLICATIONS GENERATION & NETWORK Digital Automation Measuring and Control Devices AMS7000 PROCOM The optimum operation of an electrical network depends particularly on the reliability and the availability of the protection,

More information

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 115 A - 220 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 900 ma Max. output power 40 W Nominal life-time up to 30,000 h For luminaires of protection class I and protection

More information

LED control gear Compact fixed output

LED control gear Compact fixed output Driver LC 40W 900mA fixc SR SNC ESSENCE series Product description Independent fixed output LED Driver Constant current LED Driver Output current 900 ma Max. output power 39 W Nominal life-time up to 50,000

More information

KRF EMC Filters Installation, Operation and Maintenance Manual

KRF EMC Filters Installation, Operation and Maintenance Manual KRF EMC Filters Installation, Operation and Maintenance Manual KRF EMC Filters limit high frequency noise, as well as: Reduce interference Protect sensitive equipment Eliminate drive cross-talk Meet FCC

More information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63 Circuit-breaker,4p,63A Partno. NZMH1-4-A63 Articleno. 284426 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function System and cable protection Standard/Approval IEC

More information

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS SINAMICS G130 / G150 Line harmonics filter Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 / G150 Operating Instructions Mechanical installation 3 Electrical

More information

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Circuit-breaker3psystems/cableprot. Partno. NZMB2-A250 Articleno. 259090 Deliveryprogramme Range Circuit-breaker Protective function System and cable protection Standard/Approval IEC Installation type

More information

Photoelectrics Through-beam Type PA18C.T..., DC

Photoelectrics Through-beam Type PA18C.T..., DC Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:

More information

Split System Air Conditioner

Split System Air Conditioner Residential & Light Commercial HVAC Split System Air Conditioner 1 R-410A, 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz Performance: Efficiency rating of 13 SEER Cooling capacities from 1 1 2 to 5 tons

More information

Circuit-Breakers for Motor Protection Series 8523/8

Circuit-Breakers for Motor Protection Series 8523/8 > Accessories Auxiliary contacts 1 NC + 1 NO or 2 NC + 2 NO Undervoltage trip Shunt release > Switch operation with knop > Secure switching > Clear switch setting indicator > Different current setting

More information

R407C compressors. New: Semi-hermetic compressors for air-conditioning applications with R407C

R407C compressors. New: Semi-hermetic compressors for air-conditioning applications with R407C R407C compressors Semi-hermetic compressors for air-conditioning applications with R407C New: Now up to 35 bar high pressure, 74 C condensing temp. possible Compressors for R407C 35 bar - At a glance At

More information

Altman Lighting AP-150 RGBW Par Specification

Altman Lighting AP-150 RGBW Par Specification 1.01 COLOR MIXING LED WASH FIXTURE A. General 1. The fixture shall be Red, Green, Blue, and White LED luminaire with motorized zoom and DMX control. The fixture shall be the AP-150 RGBW by Altman Stage

More information

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100 Circuit-breaker,3p,160A Partno. NZMN2-M160 CatalogNo. 265724 Similar to illustration Deliveryprogram Product range Circuit-breaker Protective function Motor protection Standard/Approval IEC Installation

More information

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners SPECTRACOOL NARROW INDOOR/OUTDOOR N43 N36 N28 11000 BTU/Hr. / BTU/Hr. BTU/Hr. 3223 Watt / Watt Watt INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 CE IP 56 Internal Loop

More information

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm Low-cost Encoder with Diameter of 50 mm CSM DS_E An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. High-precision detection of automatic machine timing.

More information

Panel-Mounted Thermostat

Panel-Mounted Thermostat Data Sheet 602026 Page 1/7 Panel-Mounted Thermostat EM Series Special features Safety temperature monitor STW (STB) Safety temperature limiter STB Tested according to DIN EN 14597 and PED 2014/68/EU Brief

More information

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil Characteristics TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A - 400 V AC coil Main Range Product name Product or component type Device short name Contactor application Utilisation category Device

More information

Minicontactorrelay,2NO/2NC,DCoperated

Minicontactorrelay,2NO/2NC,DCoperated Minicontactorrelay,2NO/2NC,DCoperated Partno. DILER-22-G(24VDC) Articleno. 010042 CatalogNo. XTRM10A22TD Deliveryprogramme Product range DILER Mini-contactors Application Contactor relays Connection technique

More information

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Type: NZMN1 A100 Article No.: 259085 Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles Description Rated current = rated uninterrupted current Setting range 3 pole I

More information

Revision 1.0 Parts List Mini

Revision 1.0 Parts List Mini Revision.0 www.grindex.com Parts List 822.2 Mini Table of Contents Table of Contents Introduction... 2 Specially approved products...2 Product Description...3 Products included... 3 The data plate...3

More information

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil Bảng thông số sản phẩm Đặc diểm LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Frequency Converter Fv

Frequency Converter Fv 2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)

More information

AF-300 E11 Adjustable Frequency Drive

AF-300 E11 Adjustable Frequency Drive AF-300 E11 Adjustable Frequency Drive The AF-300 E11 adjustable frequency drive is GE s new generation of micro drives. GE recognized your need for a high-performance, full-featured compact drive and designed

More information

LED MODULES READYLINE DL

LED MODULES READYLINE DL LED MODULES READYLINE DL BUILT-IN MODULE LED-MODULE READYLINE DOWNLIGHT DL WU-M-538 / WU-M-539 / WU-M-540 Typical Applications Downlights Replacement for CFL DIRECT MAINS CONNECTION REDUCED FLICKER HIGH

More information

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners Spec-00732 F Sealed Enclosure Air Conditioners Sealed Enclosure Air Conditioners SPECTRACOOL Narrow Indoor/Outdoor N43 11000 BTU/Hr. 3223 Watt INDUSTRY STANDARDS N36 / BTU/Hr. / Watt N28 BTU/Hr. Watt UL/cUL

More information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure Box Fan R87B CSM_R87B_DS_E_4_2 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.

More information

MILLITARY SPECIFICATION SHEET

MILLITARY SPECIFICATION SHEET INCH-POUND MILLITARY SPECIFICATION SHEET 10 November 2000 SUPERSEDING MIL-R-6106/14B 10 March 1989 RELAY, ELECTRIC, PERMANENT DRIVE, 50 AMP, SPDT (DB) DOUBLE MAKE DOUBLE BREAK AUXILIARY CONTACTS (5 AMP),

More information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Model Number Structure. Ordering Information Box Fan R87B CSM_R87B_DS_E_4_4 Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting Mounts in a square cutout and conceals the hole-cut to simplify installation work.

More information

POWER SUPPLIES COAX DC INSERTERS SITUATION

POWER SUPPLIES COAX DC INSERTERS SITUATION SITUATION devices require voltage on the coax output connector and RF signals must pass from input to output on the power inserter. SOLUTION Sonora power inserters couple regulated voltage on coax cables

More information

Type: DILM25 10(24V50HZ) Article No.:

Type: DILM25 10(24V50HZ) Article No.: Type: DILM25 10(24V50HZ) Article No.: 277119 Ordering information Rated operational current AC 3 400 V I e A 25 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

LED Driver Compact fixed output

LED Driver Compact fixed output Driver LC 10W 250mA fixc R ADV ADV series Product description Fixed output built-in LED Driver Constant current LED Driver Output current 250 ma For luminaires of protection class II For ambient temperatures

More information

Datasheet - SRB301LC 24VAC/DC

Datasheet - SRB301LC 24VAC/DC 25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred

More information

Power Quality Solutions

Power Quality Solutions EPCOS Product Brief 2018 Power Quality Solutions Static Var Generator (SVG) PQvar Series EPCOS has been offering a comprehensive range of key components for Power Factor Correction (PFC) and Power Quality

More information

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil Product data sheet Characteristics LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L T, T8, TC-L Electronic ballasts PC T PRO lp 80 W 0 0 V 0/0/0 Hz, HO L D,1 0, 1 side fixing feature side fixing feature ø,1 defined lamp warm start is 1. s constant light output independent of fluctuations

More information

LED Driver Compact dimming

LED Driver Compact dimming Driver CA 15W 180-350mA flexc PH-C SR ADV ADVACED series Product description Dimmable constant current ED Driver (SEV) Independent ED Driver with cable clamps Selectable output current between 180, 250

More information

Linear Probe Encoder Page 1 of 7. Description. Features

Linear Probe Encoder Page 1 of 7. Description. Features Page 1 of 7 Description The PE series linear plunger-style optical encoder has a machined aluminum enclosure. The PE provides either single-ended or differential quadrature encoder output in a convenient

More information

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with

More information

Type: DILM12 10(24VDC) Article No.:

Type: DILM12 10(24VDC) Article No.: Type: DILM12 10(24VDC) Article No.: 276845 Ordering information Rated operational current AC 3 400 V I e A 12 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s dv/dt filter plus Voltage Peak Limiter Safety information 1 General 2 SINAMICS SINAMICS G130 Operating Instructions Mechanical installation 3 Electrical

More information

Datasheet - SRB-E-201ST

Datasheet - SRB-E-201ST 27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574

More information

10 PDUs 19 PDUs Zero-U PDUs

10 PDUs 19 PDUs Zero-U PDUs 128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex - France Tel: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 www.legrand.com 10 PDUs Page 1. GENERL CHRCTERISTICS...1 2. EQUIPMENT ND PERFORMNCE...3

More information

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100 Circuit-breaker,3p,400A Partno. LZMC3-A400-I Articleno. 111955 Similar to illustration Deliveryprogramme Product range Circuit-breaker Protective function System and cable protection Standard/Approval

More information

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment. Absolute 60-mm-dia. Rotary Encoder A High Accuracy and Durability for Automatic Equipment Stronger shaft and greater durability (120 N in the radial direction and 50 N in the thrust direction) than previous

More information

multi-function meters

multi-function meters multi-function meters eclipse 2 eclipse 7 installation and operating manual 1 GENERAL DESCRIPTION 2 INSTALLATION 3 WIRING INFORMATION 4 2 ECLIPSE 2 METERS 2.1 PROGRAMMING THE METER 5 2.2 INFORMATION 6

More information

COHERENCE ONE PREAMPLIFIER

COHERENCE ONE PREAMPLIFIER COHERENCE ONE PREAMPLIFIER OWNER S MANUAL TABLE OF CONTENTS Introduction Features Unpacking Instructions Installation Phono Cartridge Loading Basic Troubleshooting Technical Specifications Introduction

More information

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218 9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,

More information

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil Product data sheet Characteristics LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Catalogue Ignitors and power switches for HID

Catalogue Ignitors and power switches for HID Catalogue 2012 Ignitors and power switches for HID Overview Product overview Ignitor matrix Standards Page 6 Page 7 Page 8 Product information Ignitors and power switches for HID Page 9 Superimposed-pulse

More information