Next Generation Frame (NGF) 600 mm Product Family Ordering Guide

Size: px
Start display at page:

Download "Next Generation Frame (NGF) 600 mm Product Family Ordering Guide"

Transcription

1 Next Generation Frame (NGF) 600 mm Product Family Ordering Guide

2 Table of Contents Introduction...1 Frames Fiber Main Distributing Frame (FMDF)... Front Facing Fiber Main Distributing Frame (F3MDF)...3 Fiber Slim Rack... Blocks Fiber Termination Blocks (FTB) Unterminated...5 Cable Clamping Kit...6 Fiber Termination Blocks Preterminated Fiber Combination Blocks (FCB) Sliding Adapter Packs...1 Mini Value-Added Modules (Mini VAMs) Accessories Fiber Optic Terminal Jumper Storage Bay... Equipment Bay...3 End Guard... Cable Clamp Kits... Rack Installation Kits... AC Outlet Kits... Ultra Physical Contact Fiber Optic Patch Cords Index...7

3 Introduction Unprecedented growth in the telecommunications industry has driven wide-spread deployment of optical fiber over the past few years. As a result, many service providers are finding that their existing fiber frames and troughs are overflowing with large masses of optical fiber patch cords. In addition, the rapid deployment of SONET/SDH, fiber in the loop and video initiatives has created the demand for increased termination density at the fiber distributing frame. Service providers must build a sound network infrastructure that will provide a solid base for delivering the new and enhanced broadband services promised by the ever-advancing information superhighway. What's Next? It's clear that simply adding additional fiber frames to an existing FDF lineup is not the answer, as conventional fiber frames allow only a small number of bays in a lineup before the horizontal trough system becomes unmanageable. A more innovative fiber management plan is needed that will provide unlimited expansion as well as alleviate jumper pile-up in the horizontal troughs. With the introduction of its Next Generation Frame family of products, ADC offers the innovative solution that service providers have been waiting for. Designed specifically to provide higher density while improving fiber cable management, the Next Generation Frame product family allows for virtually unlimited growth. Frames ADC's Next Generation Frame product line has fiber frames designed to fit a variety of termination, splice, and storage applications. Each frame option is designed with an emphasis on superior cable management and ease of use, including features such as ample trough space for cable and jumpers, easy access to connectors, and storage for jumpers. The frame sections are shipped from the factory fully equipped with all cable management hardware including a built-in jumper storage panel. Fiber Termination Blocks (FTB) Fiber Termination Blocks (FTBs) are available with SC, FC, ST and E-000 adapters in block configurations of 8, 7 or 96 positions. Also, 1 position FTBs are available using LX.5 and LC adapters. FTBs utilize sliding adapter packs to gain easy access to both the front and rear connectors. There is also a block configuration available to accommodate Mini Value-Added Modules (Mini VAMs) for applications requiring splitters or WDMs. FTBs can be ordered with or without IFC or outside plant cable. Fiber Combination Blocks Blocks (FCB) Fiber Combination Blocks (FCBs) provide termination and on-frame splicing capabilities, all in one block. The block occupies two mounting positions on the frame section. They are available with SC, FC, ST and E-000 adapters in block configurations of 8, 7 or 96 positions. Also, 1 position FCBs are available using LX.5 or LC adapters. Features and Benefits Ample Trough Space Reduces jumper pile-up and congestion - Reduces maintenance time due to easy removal and tracing of jumpers - Minimizes risk of microbends or damage to fiber Built-in Jumper Storage Panel Minimizes number of required jumper lengths Maintains fiber bend radius Simplifies frame installation - Saves money by reducing the number of different jumper lengths that have to be kept in inventory - Minimizes risk of microbends or damage to fiber Sliding Adapter Packs Promotes high density Provides easy access to connectors - Saves valuable floor space - Reduces time required for operations and maintenance Intelligent Cable Routing System No fiber cross-over points Multiple vertical troughways - Reduces maintenance time due to easier removal and tracing of jumpers and minimizes fiber weaving 1

4 Fiber Main Distributing Frame (FMDF) The FMDF is the cornerstone of the NGF product line. This innovative frame has six rear horizontal troughs. This abundant trough space minimizes fiber pile up and congestion leading to easier jumper traceability and removal. The frame has twelve Fiber Termination Block (FTB) mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below. The frame is 600 mm wide x 600 mm deep. The built-in jumper storage panel will store up to 5 meters of jumper slack. Ordering Information Description Jumper Storage Panel 600 mm FMDF Frame Section Left Vertical Right Vertical Dimensions FTB Mounting Position (1) 600 mm 600 mm. m x 600 mm x 600 mm Horizontal Trough (6) Front ISO View Front View Side View NGF-ETSIMDF6060

5 Front Facing Fiber Main Distributing Frame (F3MDF) 3/03 85 Next Generation Frame 600 mm Products The F3MDF is designed for single-sided access applications and may be mounted up against a wall or back-to-back to save floor space. Unlike the FMDF, the more compact F3MDF is equipped with a single 30 mm horizontal trough. The F3MDF has twelve FTB mounting positions equally divided between vertical columns on the left and right sides of the frame as shown in the figure below. The frame is 600 mm wide x 80 mm deep. The built-in jumper storage panel will store up to 5 meters of jumper slack. Jumper Storage Panel Left Vertical Right Vertical FTB Mounting Position (1). m 600 mm 80 mm Front ISO View Front View Side View Ordering Information Description 600 mm F3MDF Frame Section Dimensions. m x 600 mm x 80 mm NGF-ETSIF3MDF608 Horizontal Trough (6) 3

6 Fiber Slim Rack 3/03 85 Next Generation Frame 600 mm Products The Fiber Slim Rack is designed for lower density applications than the FMDF or F3MDF. It has six FTB mounting positions and is designed for single-sided access applications. The Slim Rack is intended for use in a single frame application and should not be used in a multiframe lineup. The built-in jumper storage panel will store up to 5 meters of jumper slack. When ordering FTBs for the Slim Rack, remember that only left oriented blocks are used on this frame. FTB Mounting Position Jumper Storage Panel.1 m 80 mm 80 mm Front ISO View Front View Side View Ordering Information Description NGF Fiber Slim Rack Frame Section Dimensions.1 m x 80 mm x 80 mm NGF-SLM7A100

7 Fiber Termination Blocks (FTB) Unterminated FTBs without fiber can be ordered fully loaded with adapters or empty (no adapters), in which case the adapter packs for the block must be ordered separately (see page 1). Before ordering, determine the block orientation and cable exit direction. Unterminated FTBs may be ordered with a left orientation (mounts on the left side of the frame) or a right orientation (mounts on the right side of the frame). The cable exit direction will be either upward (cables terminated to the rear side of the block exit up toward the top of the frame) or downward (cables terminated to the rear side of the block exit down toward the bottom of the frame). All blocks with adapters only are configured to terminate single or dual jumpers on the rear of the block. If a multi-fiber breakout style cable (i.e., OSP/IFC) is to be terminated to the rear of the block, a separate clamping kit is required (see page 6). Block Style SC FC/ST E-000 LX.5 /LC Block Configuration A B C M (LX.5 or LC only)* NGF-TB * 1 blocks using style 1,, or 3 cannot be used in 6" wide NGF frames Definition of Variables Block Orientation 3 L Left R Right Cable Exit Direction U Upward D Downward Block Style General adapter type required in the FTB Adapter Type Singlemode L 3 Q V N X K SC ultra polish SC ultra polish, zirconia sleeve SC 8 angled polish FC ultra polish FC ultra polish, zirconia sleeve FC 8 angled polish ST ultra polish E-000 angled polish LX.5 ultra polish (1 only) LX.5 angled polish (1 only) LC ultra polish (1 only) Block Configuration Maximum number of terminations that the FTB will accommodate when fully loaded Block Orientation Vertical column of the frame the FTB is to be mounted on Cable Exit Direction Direction the equipment jumpers or OSP cable will exit from the FTB Adapter Type Specific adapter type required in the FTB OR Adapter Type (6.5/15) Multimode 9 A 5 Y P SC FC ST LX.5 (1 only) LC (1 only) 5

8 Fiber Termination Blocks Cable Clamping Kit Clamping kit includes: Cable clamp, protective cover and fanout bracket. It is required when terminating a multifiber breakout style cable to the rear of the block. 7 position block loaded with jumpers Ordering Information Description 7 position block loaded with multifiber breakout cable Block style originally purchased All 8- and 7-position blocks NGF-ACCOSPKIT0 96-position blocks with rear cable management NGF-ACCOSPKIT01 as shown above (blocks ordered before June or 1-position Left Up Blocks NGF-ACCRCMSLU 96- or 1-position Right Up Blocks NGF-ACCRCMSRU 96- or 1-position Left Down Blocks NGF-ACCRCMSLD 96- or 1-position Right Down Blocks NGF-ACCRCMSRD 7 position block with clamping kit Rear Cable Management Tray for 1 Block Conversion Kit Protective Cover Fanout Bracket 6

9 Fiber Termination Blocks (FTB) Preterminated Preterminated FTBs are available with either indoor or outdoor rated cable in ribbon or stranded configurations. All blocks are 100% factory tested to guarantee continuity and reliable connections. Preterminated FTBs make installation quick and easy, reducing labor costs. Before ordering, determine the block orientation and cable exit direction. Preterminated FTBs may be ordered with a left orientation (mounts on the left side of the frame) or a right orientation (mounts on the right side of the frame). The cable exit direction will be either upward (cables terminated to the rear side of the block exit up toward the top of the frame) or downward (cables terminated to the rear side of the block exit down toward the bottom of the frame). Preterminated Fiber Termination Blocks arrive from the factory with either IFC or OSP Cables Fiber cable easily uncoils during installation Ordering information follows on next page. Definition of Variables 1 Block Style General adapter type required in the FTB Fiber Termination Block ships inside the drum Block Configuration Maximum number of terminations that the FTB will accommodate when fully loaded 3 Block Orientation Vertical column of the frame the FTB is to be mounted on Cable Exit Direction Direction the equipment jumpers or OSP cable will exit from the FTB 5 Adapter/Connector #1 Specific adapter/connector type required in the FTB. Refers to the adapter/ connector type at the FTB 6 Connector # Specific connector type required at the cable end opposite the FTB 7 Cable Type Type of cable to be terminated to the FTB 8 Cable Length Required length of the cable terminated to the FTB Fiber Termination Block loaded with multifiber breakout cable 7

10 Preterminated FTBs Block Style SC FC/ST E-000 LX.5 /LC NGF-TB Block Configuration A B C M (LX.5 or LC only)** Block Orientation 3 L R Left Right Cable Exit Direction U D Upward Downward 0 9 A 5 Y P Adapter Type Singlemode L 3 Q V N X K OR Adapter/Connector #1 Multimode (6.5/15) 9 A 5 Y P Connector # Singlemode L 3 Q V N X K No connector/stub end SC ultra polish SC ultra polish, zirconia sleeve SC 8 angled polish FC ultra polish FC ultra polish, zirconia sleeve FC 8 angled polish ST ultra polish E-000 angled polish LX.5 ultra polish (1 only) LX.5 angled polish (1 only) LC ultra polish (1 only) Connector # Multimode (6.5/15) SC ultra polish SC ultra polish, zirconia sleeve SC 8 angled polish FC ultra polish FC ultra polish, zirconia sleeve FC 8 angled polish ST ultra polish E-000 angled polish LX.5 ultra polish (1 only) LX.5 angled polish (1 only) LC ultra polish (1 only) SC FC ST LX.5 (1 only) LC (1 only) No connector/stub end SC FC ST LX.5 (1 only) LC (1 only) OR IFC Type Singlemode 7 ZB 7 fiber stranded ZC 96 fiber stranded ZD 1 fiber stranded AA 1 fiber stranded BA fiber stranded CA 36 fiber stranded A 8 fiber stranded 7A 5 fiber stranded VA 7 fiber stranded DA 96 fiber stranded FH 1 fiber stranded GA 1 fiber ribbon HA fiber ribbon MA 36 fiber ribbon JA 8 fiber ribbon KA 7 fiber ribbon EG 96 fiber ribbon FJ 1 fiber ribbon KB 7 fiber ribbon EF 96 fiber ribbon FK 1 fiber ribbon OR OR IFC Type Multimode (6.5/15) AM BM DM M VM WM 1 fiber stranded fiber stranded 36 fiber stranded 8 fiber stranded 7 fiber stranded 96 fiber stranded Cable Length 8 XXX Length in meters OSP Cable Type Singlemode VP VT VU VW EN FL FM 7 fiber ribbon dielectric 7 fiber stranded dielectric 96 fiber ribbon dielectric 96 fiber ribbon dielectric 96 fiber stranded dielectric 1 fiber stranded dielectric 1 fiber ribbon dielectric Glass Type House Cable* House Cable* House Cable* Corning Corning Corning Corning Corning Corning Corning Corning Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo Sumitomo Alcatel Alcatel Alcatel Glass Type Corning Corning Corning Corning Corning Corning Glass Type Alcatel Pirelli Alcatel Pirelli Pirelli Pirelli Pirelli Other cable types are available upon request. Please contact your ACD representative. * House cable will use Corning SMF8, Sumitomo, Alcatel or similar singlemode fiber based on current market availability. ** 1 blocks using style 1,, or 3 cannot be used in 6" wide NGF frames See previous page for definition of variables. 8

11 Fiber Combination Blocks (FCB) Fiber Combination Blocks provide a place to terminate pigtails and splice IFC/OSP cables on the frame. The blocks are available with several different adapter types in block configurations of 8, 7, or 96 positions. Also, a 1 position FCB is available using an LX.5 adapter. The termination portion of the fiber combination block utilizes sliding adapter packs to gain easy access to connectors on both the front and rear side of the block. The block is available with factory-installed pigtails for easy installation. Splice trays are shipped with the block if ordered with pigtails; otherwise trays must be ordered separately. The block is shipped with a cable clamp for OSP/IFC. The FCB occupies two mounting positions on a frame section. Before ordering, determine the block orientation. FCBs may be ordered with a left orientation (mounts on the left side of the frame) or a right orientation (mounts on the right side of the frame). Ordering information follows on next page. 9

12 Fiber Combination Blocks (FCB) Block Style SC FC/ST E-000 LX.5 /LC Block Configuration A B C M (LX.5 or LC only) Block Orientation 3 L R Left Right 1 NGF-CB Adapter Type Singlemode 7 8 L 3 Q V N X K SC ultra polish SC ultra polish, zirconia sleeve SC 8 angled polish FC ultra polish FC ultra polish, zirconia sleeve FC 8 angled polish ST ultra polish E-000 angled polish LX.5 ultra polish (1 only) LX.5 angled polish (1 only) LC ultra polish (1 only) Adapter/Connector Type Multimode (6.5/15) A 5 9 Y P FC ST SC LX.5 (1 only) LC (1 only) 1 1 termination block requires the use of either: Mechanical (elastomeric) splice tray when using mass fusion ribbon splicing Nortel QPAK splice tray when using single fiber heat shrink fusion splicing 1 blocks using block style 1,, or 3 cannot be used in 6" wide NGF frames Definition of Variables Block Style General adapter type required in the FCB Pigtail Type Block Configuration Maximum number of terminations that the FCB will accommodate when fully loaded Block Orientation Vertical column of the frame the FCB is to be mounted on Adapter/Connector Type Specific adapter/connector type required in the FCB Pigtail Type Type of pigtail required Number of Pigtail Assemblies Number of pigtails to be pre-installed in the FCB Splice Chip Type of splice chip required for splice trays 5 No pigtails 1 fiber pigtail 1 fiber stranded Maxi-Strip 8 fiber pigtail 1 fiber ribbon Number of Pigtail Assemblies 6 XX Number of assemblies Splice Chip 7 0 Empty 1 Bare fusion Heat shrink fusion 3 Mechanical (elastomeric) OR 6 Nortel QPAK 7 Swiss ANT 8 Rotary 9 FibrLok 16 position heat shrink fusion 10

13 Splice Trays For Fiber Combination Block FST - DRS Number of Splices splices splices Note: For LX.5 FCB with 1 fiber ribbon pigtails, select mechanical splicing only. For LX.5 FCB with 1 fiber stranded pigtails select Nortel QPAK (compatible with heat shrink fusion), bare fusion or Swiss ANT only. - Splice Tray Type 00 FT HS MT NT ANT RT 3M Empty tray* Bare fusion Heat shrink fusion Mechanical (elastomeric) Nortel QPAK Swiss ANT Rotary FibrLok * Maximum size of chip allowed in empty tray:.3"h x.5"w x 3.6"L 11

14 Next Generation Frames Sliding Adapter Packs Sliding adapter packs house groups of fiber optic adapters and are mounted in Fiber Termination Blocks to provide easy access to connectors. Sliding Adapter Packs are available with SC, FC, ST, E-000 and LX.5 adapters. The adapters come in packs of two, four, six and eight depending on the adapter type and the desired termination density. See table below for configuration guidelines. 8-Position 7-Position 7-Position 96-Position 96-Position 96-Position 1-Position (block code'e') 1-Position (block code'm') Option A (SC shown) Adapter Type Singlemode L 3 Q V N X K Block Configuration * Sliding Adapter Pack Configuration Guidelines Option B (FC shown) SC ultra polish SC ultra polish,zirconia sleeve SC 8 angled polish FC ultra polish FC ultra polish, zirconia sleeve FC 8 angled polish ST ultra polish E-000 angled polish LX.5 ultra polish (1 only) LX.5 angled polish (1 only) LC ultra polish (1 only) Adapter Type SC, FC, ST, E-000 SC, E-000 FC, ST SC, E-000 FC, ST SC, FC, ST, E-000 LX.5 SC, FC, E-000, LX.5, LC Option E (ST shown) NGF- SAP OR Adapter Pack Configuration Pack / Pack Pack / Pack 6 Pack Pack / 6 Pack 8 Pack Pack / Pack 1 Pack 6 Pack / 6 Pack Option F (E-000 shown) Adapter Type Multimode 9 A 5 Y SC FC ST LX.5 (1 only) Option G (FC shown) Adapter Pack Option* A B E F G H J K Adapter Pack Option B (shown below) A (shown below) E (shown below) F (shown below) G (shown below) J (not shown below) H (not shown below) K (not shown below) Option H (LX.5 only) pack/ pack pack/ pack 6 pack pack/6 pack 8 pack 1 pack (LX.5 block code "E" only) pack / pack 6 pack / 6 pack (all block code "M" blocks) 1

15 Next Generation Frames Value-Added Module System ADC s Next Generation Frame (NGF) Value-Added Modules are designed to support emerging circuit requirements. This high-density fiber frame solution provides unlimited expansion while optimizing fiber cable management. The NGF system uses Mini Value-Added Modules to incorporate optical splitters for circuit monitoring and video distribution. Mini Value-Added Modules can also be configured with wavelength division multiplexing capabilities to increase transmission capacity over existing fiber lines. Various input and output interface options are available. VAM Chassis The NGF VAM chassis is designed to mount on all standard NGF frame styles and is interchangeable with termination, splice, and storage modules. Each chassis accommodates up to twelve Mini-VAM modules. Block Style 1 3 SC FC/ST E-000 NGF - TB D Features: Enclosed plug-in modules Optical components are protected from physical and environmental damage Flexible platform Modules can be created for new applications quickly and easily to meet customer requirements Monitor and/or test Enables providers to troubleshoot networks without forcing disruption of service Custom configurations Custom splitter configurations available upon request Cable Exit Direction (Rear) U D Block Orientation L R Upward Downward Left Right * NGF VAMs with LX.5 or LC adapters can be placed in any of these block styles. Please contact ADC Technical Assistance Center at with any questions. NGF VAM Chassis 13

16 Next Generation Frames Value-Added Module System Video Splitter Module Ordering Information Module Option Input Front, Output Front REAR IN OUT 1 x N FRONT OUTPUT OUTPUT INPUT INPUT Output Front REAR IN 1 x N NGF-V Input front, output front 5 Input rear, output front Split Ratio 000 1x 50/50 Input Connector/Adapter Singlemode U FC ultra polish A FC angled polish 7U SC ultra polish 7A SC angled polish U ST ultra polish 8A E-000 angled polish LU LX.5 ultra polish LA LX.5 angled polish KU LC ultra polish 00 Bare fiber or Multimode** M FC 6.5/15 N FC 50/15 9A SC 50/15 9B SC 6.5/15 5F ST 50/15 5U ST 6.5/15 LM LX.5 PM LC 00 Bare fiber 100 1x 55/5 00 1x 60/ x 65/ x 66.6/ x 70/ x 75/ x 80/ x 85/ x 90/ x 95/ x 99/ x 50/ x3 33/33/ x 5/5/5/ x5 0/0/0/0/ x6 16.6/16.6/ /6/16.6/ x7 1.3/1.3/1.3/ /1.3/ x8 1.5/1.5/ Output Connector/Adapter Singlemode U FC ultra polish A FC angled polish 7U SC ultra polish 7A SC angled polish U ST ultra polish 8A E-000 angled polish LU LX.5 ultra polish LA LX.5 angled polish KU LC ultra polish 00 Bare fiber OUT FRONT INPUT OUTPUT OUTPUT OUTPUT OUTPUT or Multimode** M FC 6.5/15 N FC 50/15 9A SC 50/15 9B SC 6.5/15 5F ST 50/15 5U ST 6.5/15 LM LX.5 PM LC 00 Bare fiber OUT OUT Splitter Type LEAVE BLANK G J Wideband 1310 and 1550 nm 1310 nm wavelength flattened 1550 nm wavelength flattened Output Pigtail Length (in meters) Example: 00 = No pigtail 01 = 1 meter 10 = 10 meters Input Pigtail Length (in meters) Example: 00 = No pigtail 01 = 1 meter 10 = 10 meters Leave 00 for adapter option Number of Splitters A Single splitter B Dual splitter C Triple splitter Other split ratios are available. Call ADC Technical Assistance Center at **Contact ADC for multimode specifications and available split ratios 5 Input Rear, Output Front 3 Input Front, Output Rear 1

17 Next Generation Frames Value-Added Module System Singlemode Wideband Optical Splitter Specifications Other splitter configurations are available. Please call ADC Technical Assistance Center, Splitter Number A110 B111 C11 D113 E11 F115 G116 M13 Splitter Type 1x 1x 1x 1x 1x 1x 1x 1x 1x 1x 1x 1x x 1x3 1x 1x5 1x6 1x7 1x8 1x9 1x10 1x11 1x1 1x13 1x1 1x15 1x16 1x3 Splitter Ratio 50/50 55/5 60/0 65/ / /30 75/5 80/0 85/15 90/10 95/5 99/1 50/50 33/33/33 5/5/5/5 0/0/0/0/0 16.6/16.6/ /1.3/... / /1.5/ /11.1/... / /10/10... /10 9.1/9.1/... / /8.3/... / /7.7/... / /7.1/... / /6.66/... / /6.5/ /3.13/ Maximum Insertion Loss* 3.7/3.7 3./.1.7/.7.3/5.3./5.5.0/ / / /9..8/11..5/1. 0.3/.5 3.7/ /5.9/5.9 7./7./7./7. 8.6/8.6/8.6/8.6/ /9.8/9.8/.../ /10.6/... / /11.3/... / /11.5/... / /1.1/... / /13.1/... / /13.3/... / /13.8/... / /13.8/... / /1.5/... / /1.9/ /18.5/... 18/5 Typical Insertion Loss* 3.1/3.1.7/3.6.3/.1.0/.7 1.9/ /5. 1./6. 1.1/7.1.8/8..6/10../13. NA/NA 3.1/ /5.0/5.0 6./6./6./6. 7.3/7.3/7.3/7.3/ /8.1/ / /8.9/... / /9.5/.../ /9.9/... / /10./... / /10.9/... / /11.3/... / /11.6/... / /11.8/... / /1./... /1. 1.6/1.6/ /15.8/ * Does not include connector loss. See table on the following page or call ADC Technical Assistance Center, Maximum Insertion Loss Maximum insertion loss is the upper limit of insertion loss for the coupler and applies over the entire wavelength range specified in the bandpass. Typical Insertion Loss Typical insertion loss is the expected insertion loss value for the coupler measured at the specified center wavelength (i.e., 1310 nm and/or 1550 nm). 15

18 Next Generation Frames Value-Added Module System Singlemode Optical Splitter Specifications MATERIAL Fiber: Jacket: Housing: OPTICAL Bandpass Wavelength 1: Wavelength : Directivity: Reflectance: Polarization Stability: MECHANICAL Cable Retention: Flex: Twist: Vibration: Impact: Flammability: ENVIRONMENTAL Humidity: Thermal Aging: Temperature Cycling: Corning SMF mm hytrel tube Stainless steel tube 160/1360 nm 130/1580 nm 55 db minimum < -55 db.5 db maximum.5 kg (1.0 lb.) maximum for.5 mm and.900 mm fiber, 1 kg (. lbs.) maximum for cabled fiber assemblies 300 cycles;.5 kg (1.0 lb.) maximum load (fiber cable only) 100 cycles;.5 kg (1.0 lb.) maximum load (fiber cable only) Hz per FOTP II condition I 8 drops from 1.5 meters All materials used in fabrication of coupler housing meet UL 9, Level V-I requirements 336 hours, 60 C at 95% relative humidity 336 hours, 85 C 336 hours, -0 C to 85 C Singlemode Optical Connector Specifications Ultra Polish PC Connectors: Angled Polish Connectors: INSERTION LOSS (db) 0.3 db maximum 0.15 db typical 0.5 db maximum 0. db typical RETURN LOSS (db) 57 db minimum 65 db minimum 16

19 Next Generation Frames Value-Added Module System WDM Module Ordering Information Configuration MUX front, DEMUX front 5 MUX rear, DEMUX front Mux Port Connector/Adapter U FC ultra polish A FC angled polish U ST ultra polish 7U SC ultra polish 7A SC angled polish 8A E-000 angled polish LU LX.5 ultra polish LA LX.5 angled polish KU LC ultra polish 00 Bare fiber Demux Port Connector/Adapter U FC ultra polish A FC angled polish U ST ultra polish 7U SC ultra polish 7A SC angled polish 8A E-000 angled polish LU LX.5 ultra polish LA LX.5 angled polish KU LC ultra polish 00 Bare fiber In the ordering charts, the abbreviation mux references the multiplexed side of the WDM, the side where two optical signals coexist on one fiber. The abbreviation demux references the demultiplexed side of the WDM, the side where each signal appears on its own fiber. Both unidirectional and bidirectional WDMs are available as shown below. DEMUX UNIDIRECTIONAL MULTIPLEXER MUX MUX UNIDIRECTIONAL DEMULTIPLEXER NGF-W Module Configuration A Single B Dual C Triple WDM Type (λ1, λ) A Undirectional multiplexer C Undirectional demultiplexer E Bidirectional λ1 Tx/λ Rx G Bidirectional λ1 Rx/λ Tx J 5 db isolation, pass 1310 K 5 db isolation, pass 1550 L (Dual only) unidirectional multiplexer, undirectional demultiplexer* M (Dual only) bidirectional λ1 Tx/λ Rx, bidirectional λ Tx/λ1 Rx * WDM Type "L" includes (1) unidirectional multiplexer (standard isolation) and (1) unidirectional demultiplexer (isolation specified by next character) DEMUX DEMUX MUX BIDIRECTIONAL TRANSMISSION MUX DEMUX Demux Port Pigtail Length Length (in meters) Example: 00 = No pigtail 01 = 1 meter 10 = 10 meters Mux Port Pigtail Length Length (in meters) Example: 00 = No pigtail 01 = 1 meter 10 = 10 meters Leave 00 for adapter option Wavelength A 1310 (λ1)/1550(λ) B 1533 (λ1)/1557(λ) E 1550 (λ1)/165(λ) F 1310 (λ1)/165(λ) Isolation 1 Standard High 3 Very high 17

20 Next Generation Frames Value-Added Module System WDM Module Mux Front, Demux Front REAR WDM FRONT Demux Demux Mux 5 Mux Mux Rear, Demux Front REAR WDM FRONT Demux Demux 18

21 Next Generation Frames Value-Added Module System Singlemode WDM Specifications MATERIAL Fiber: Jacket: OPTICAL Uniformity: Polarization Stability: Bandpass: Insertion Loss: Reflectance: Isolation Near End: Far End: MECHANICAL Cable Retention: Flex: Twist: Vibration: Impact: Flammability: ENVIRONMENTAL Humidity Resistance: Thermal Aging: Temperature Cycling: Multiplexer/Demultiplexer: High Isolation Demultiplexer: Very High Isolation Demultiplexer: Wavelength Filters: Corning SMF mm 1.0 LogN (where N = number of channels) 0.5 db maximum (see table below) (see table below) < -55 db 55 db (see table below).5 kg (1.0 lb.) maximum for.50 mm and.900 mm fiber; 1.0 kg (. lbs.) maximum for cabled fiber assemblies 300 cycles;.5 kg (1.0 lb.) maximum load (fiber cable only) 100 cycles;.5 kg (1.0 lb.) maximum load (fiber cable only) Hz per FOTP II condition I 8 drops from 1.5 meters All materials used in fabrication of the coupler housing meet UL 9, Level V-I requirements 336 hours, 60 C at 95% relative humidity 336 hours, 85 C 336 hours, -0 C to 85 C 1310/1550 nm PASSBAND MAXIMUM INSERTION LOSS* (nm) (db) 1533/1557 nm Unidirectional Multiplexer: High Isolation Undirectional Multiplexer or Bidirectional Multiplexer/Demultiplexer: Very High Isolation Undirectional Multiplexer or Bidirectional Multiplexer/Demultiplexer: Filter Passing 1533 nm: Filter Passing 1557 nm: 1310 ± 0 nm and 1550 ± 0 nm 1310 ± 0 nm and 1550 ± 0 nm 1310 ± 0 nm and 1550 ± 0 nm 1310 ± 0 nm and 1550 ± 0 nm PASSBAND (nm) 1533 ±3 and 1557 ±3 nm 1533 ±3 and 1557 ±3 nm 1533 ±3 and 1557 ±3 nm 1533 ±3 nm 1557 ±3 nm MAXIMUM INSERTION LOSS* (db) * Maximum Insertion Loss does not include connector loss. See pages for connector specifications and definitions MINIMUM ISOLATION (db) MINIMUM ISOLATION (db) N/A

22 Next Generation Frames Value-Added Module System Monitor Module Ordering Information Input Connector/Adapter Singlemode U FC ultra polish A FC angled polish 7U SC ultra polish 7A SC angled polish U ST ultra polish 8A E-000 angled polish LU LX.5 ultra polish LA LX.5 angled polish KU LC ultra polish 00 Bare fiber or Multimode** M FC 6.5/15 N FC 50/15 9A SC 50/15 9B SC 6.5/15 5F ST 50/15 5U ST 6.5/15 LM LX.5 PM LC 00 Bare fiber Output Connector/Adapter Singlemode U FC ultra polish A FC angled polish 7U SC ultra polish 7A SC angled polish U ST ultra polish 8A E-000 angled polish LU LX.5 ultra polish LA LX.5 angled polish KU LC ultra polish 00 Bare fiber or Multimode** M FC 6.5/15 N FC 50/15 9A SC 50/15 9B SC 6.5/15 5F ST 50/15 5U ST 6.5/15 LM LX.5 PM LC 00 Bare fiber NGF-M Monitor Pigtail Length Number of Circuits per VAM 1 1 circuit Output Pigtail Length circuits 3 3 circuits Input Pigtail Length Length (in meters) Split Ratio Example: A 90/10 00 = No pigtail B 95/05 01 = 1 meter C 50/50 10 = 10 meters E 80/0 Leave 000 for F 75/5 adapter option H 70/30 J 60/0 K 99/01 Module Style B Cross-connect customer premises D Dual monitor cross-connect Monitor Connector Type G Dual monitor cross-connect Singlemode J Dual monitor U FC ultra polish P Customer premises A FC angled polish R Single monitor cross-connect 7U SC ultra polish 7A SC angled polish U ST ultra polish * See detailed splitter and connector 8A E-000 angled polish specifications on pages LU LX.5 ultra polish Contact ADC for multimode LA LX.5 angled polish specifications and available split ratios KU LC ultra polish at Bare fiber or Multimode** M FC 6.5/15 N FC 50/15 9A SC 50/15 9B SC 6.5/15 5F ST 50/15 5U ST 6.5/15 LM LX.5 PM LC 00 Bare fiber 0

23 Next Generation Frames Value-Added Module System Monitor Module J Mon tor Modu e XX% 1 x SPLITTER B XX% XX% 1 x SPLITTER A XX% Dual Monitor Cross-Connect 1 x 1 x CUST MON SRC MON SRC Rx CUST Rx CUST Tx SRC Tx Mon Tx Mon Rx Tx Rx Tx SRC Rx SRC CUST MON Tx Rx P SRC MON Cross Connect 10% SPLITTER 90% 10% SPLITTER 90% Customer Premises Monitor Module XX.XX% 1 x SPLITTER XX.XX% XX.XX% 1 x SPLITTER XX.XX% Tx MON Rx MON Tx Rx CUST Rx CUST Tx SRC Rx SRC Tx Rx Tx R Tx AI Rx Cross Connect 1 x 1 x Single Monitor Cross-Connect 1 x SPLITTER XX.XX% XX.XX% Rx Mon Tx Mon Rx Tx Tx MON A Tx A Rx 1

24 Fiber Optic Terminal Jumper Storage Bay Front ISO View Ordering Information Description FOT Storage Bay for 600 mm FMDF Lineups FOT Storage Bay for 600 mm F3MDF Lineups (not shown) 300 mm Front View (NGF-ACCFOTSB300 Shown) Dimensions. m x 300 mm x 600 mm. m x 300 mm x 80 mm. m 600 mm Side View NGF-ACCFOTSB300 NGF-F3ACCFOTSB300

25 Equipment Bay The NGF Equipment Bay provides a mounting location for 19" rack mount equipment within an FMDF lineup. The equipment deployment in the bay can include video transmitters, RF Splitter/Combiners, or Remote Fiber Test Systems. NGF Equipment Bays are available for FMDF lineups (600 mm deep) and F3MDF lineups (80 mm deep). Ordering Information Description Equipment Bay for FMDF lineups For 19" equipment (maximum equipment depth 8.6 cm) (36) rack unit mounting spaces available (EIA hole spacing) Equipment Bays for F3MDF lineups For 19" equipment (maximum equipment depth 8.6 cm) (36) rack unit mounting spaces available (EIA hole spacing) Dimensions. m x 600 mm x 600 mm. m x 600 mm x 80 mm 600 mm 600 mm NGF-ETSIEB NGF-ETSIEB NGF-ETSIF3EB m 3

26 Accessories End Guard The end guard provides protection for the fibers entering and exiting frames at the ends of a lineup. Ordering Information Description FMDF end guard, 600 mm deep F3MDF end guard, 80 mm deep Cable Clamp Kits Cable clamp kits are available for securing IFC/OSP cable or equipment (FOT) jumpers on the rear of the FTB. Ordering Information Description Cable clamp kit for FOT patch cords included with fiber termination blocks loaded with adapters only Cable clamp kit for IFC/OSP cables included with fiber termination blocks with IFC Rack Installation Kits Ordering Information Description Rack installation kit for concrete floor, kit includes: () M8 bolts, 90 mm () M8 nuts (8) flat washers () lock washers shims and anchor plates Rack installation kit for raised floor, kit includes: () threaded rods M1 x 1 m (1) heavy nuts, lock and flat washers () nuts with springs, M1 () 1.8 m unistrut (1) anchor kit AC Outlet Kits NGF-ETSIACCEG NGF-ETSIF3ACCEG NGF-ACCCLMP0 NGF-ACCCLMP08 RAC-MX0616 RAC-MX0615 Please contact your ADC representative for catalog numbers

27 Next Generation Frames Patch Cords Singlemode Cable Option FPC FPT Connector on both ends (patch cord) Connector on one end (pigtail) Multimode Cable Option FPC Connector on both ends (patch cord) FPT Connector on one end (pigtail) - - S - M Length X Length in meters Cable Type Connector Type 1 Leave 3 mm single SPSC SC ultra polish Blank M mm single APSC SC angled polish F 1.7 mm single SDSC SC duplex micron SPFC FC ultra polish Z 3 mm dual zip APFC FC angled polish mm dual zip SPST ST ultra polish T 1.7 mm dual zip AE E-000 angled polish SPLX LX.5 ultra polish 3 1 For hybrid patch cords, enter both connector types in this field and separate them with a slash mark; ALX5 SDLX LX.5 angled polish 3 LX.5 ultra polish duplex remove "S" from the ultra polish connector options ADLX LX.5 angled polish duplex (see second ordering example). One connector per end; requires dual zip cable 3 Requires 900 micron, 1.7 mm or mm cable Requires 1.7 mm or mm dual zip cable Ordering Example SPLC SDLC LC ultra polish LC ultra polish duplex FPC-SPFC-10M: Patch cord with ultra polish FC connectors on both ends, mm dual zip cable, 10 meters in length with standard breakout length of 1" on both ends. FPC-SPST/PSC-S-10M: Patch cord with ST ultra polish connector on one end and SC ultra polish connector on the other end, 10 meters in length M Length X Length in meters Cable Type Fiber Size Leave Blank 3 mm single M mm single A 50/15 F 1.7 mm single B 6.5/ micron Z 3 mm dual zip Connector Type 1 mm dual zip MSC SC ultra polish T 1.7 mm dual zip MDSC SC duplex 1 MFC FC ultra polish For hybrid patch cords, enter both connector types MST ST ultra polish in this field and separate them with a slash mark MLX5 LX.5 ultra polish 3 One connector per end; requires dual zip cable 3 MDLX LX.5 duplex Requires 900 micron, 1.7 mm or mm cable MLC LC ultra polish Requires 1.7 mm or mm dual zip cable MDLC LC duplex Ordering Example FPC-MST/MSC-B-7M: Patch cord with ST ultra polish connector on one end and SC ultra polish connector on the other end, 6.5/15 fiber size, 7 meters in length. 5

28 Next Generation Frames Cable Assemblies Standard Cross-Connect Patch Cord Lengths Total Number of Sections Traversed Same frame Adjacent frames 3 to 5 to 6 7 to 8 9 to 10 Patch Cord Length (approximate) Feet Meters *Depending on office requirements, 11 or more frame sections may require the use of interbay tie panels. For additional information, please call ADC Technical Assistance Center,

29 Index N NGF-ACCCLMP0... NGF-ACCCLMP08... NGF-ACCFOTSB NGF-ACCOSPKIT NGF-ACCOSPKIT0...6 NGF-ETSIACCEG... NGF-ETSIF3ACCEG... NGF-ETSIEB NGF-ETSIF3EB NGF-ETSIF3MDF NGF-ETSIMDF NGF-F3ACCFOTSB NGF-SLM7A R RAC-MX RAC-MX

30 Web Site: From North America, Call Toll Free: Outside of North America: Fax: For a listing of ADC s global sales office locations, please refer to our web site. ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer 85 6/03 Revision 1999, 000, 001, 003 ADC Telecommunications, Inc. All Rights Reserved

NGF optical distribution frame

NGF optical distribution frame NGF optical distribution frame Contents Introduction 3 Product overview 3 Things to consider when ordering 4 Frame capacity requirements (important facts on trough space) 4 Frame lineup capacity comparisons

More information

Fiber Optic Patchcords & Cable Assemblies. Exclusive CD edition March 2006

Fiber Optic Patchcords & Cable Assemblies. Exclusive CD edition March 2006 Fiber Optic Patchcords & Cable Assemblies Exclusive CD edition March 2006 Fibre Optic Patch Cords Singlemode - - - M Cable Option FPC Connector on both ends (patch cord) FPT Connector on one end (pigtail)

More information

Next Generation Frame (NGF) Fiber Combination Block (FCB) User Manual)

Next Generation Frame (NGF) Fiber Combination Block (FCB) User Manual) Next Generation Frame (NGF) Fiber Combination Block (FCB) User Manual) Fiber Combination Block Content Page INTRODUCTION............................................................................. 2 Revision

More information

LGX Compatible (LSX) Connector Module) User Manual)

LGX Compatible (LSX) Connector Module) User Manual) LGX Compatible (LSX) Connector Module) User Manual) 15948-A LSX Connector Module (72-Position Module Shown) Content Page 1 DESCRIPTION... 3 2 DIMENSIONS AND SPECIFICATIONS... 5 3 INSTALLATION... 6 3.1

More information

Singlemode Patch Cords and Pigtails

Singlemode Patch Cords and Pigtails Singlemode Patch Cords and Pigtails TECHNICAL DATA Description ADC KRONE offers a wide array of singlemode fibre optic patch cords, featuring Riser and LSZH cables. ADC KRONE s singlemode connectors are

More information

LTX Optical Distribution Panels. Ordering Guide

LTX Optical Distribution Panels. Ordering Guide Contents LTX Optical Distribution Panels... 1... 1 Section One: LTX Overview... 3 1RU and 2RU Panels... 3 4RU Panels... 3 Patch Panels... 3 Combination Panels Patch and Splice... 4 Section Two: Unloaded

More information

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights In-Building Wireless Networking System InterReach Fusion is the latest addition to ADC s portfolio of Distributed Antenna Systems. It offers the same superior performance as Unison in an easy-to-install,

More information

Common Public Radio Interface Fiber :: Telect HDX & ELF CPRI Panels and Modules

Common Public Radio Interface Fiber :: Telect HDX & ELF CPRI Panels and Modules Overview Telect's HDX and ELF CPRI Interface Panels and Modules provide non-service affecting monitor ports to be installed between the Optical CPRI Base Band Unit (BBU) and the Remote Radio Head/ Active

More information

SPECIFICATION. Spec No : VSS-1402-CS603B

SPECIFICATION. Spec No : VSS-1402-CS603B SPECIFICATION Spec No : VSS-1402-CS603B 1. INTRODUCTION 1.1. General This specification covers the design requirements and characteristics required of fiber optic splice closures to be used on fiber optic

More information

IP-LINX. Installation Guide

IP-LINX. Installation Guide Installation Guide Installation Guide, 146653-4 Copyright 2017, Telect, Inc. All Rights Reserved Telect and Connecting the Future are registered trademarks of Telect, Inc. 22425 East Appleway Ave. # 11

More information

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Traditional RF Splitter/Combiner and Directional Coupler User Manual Traditional RF Splitter/Combiner and Directional Coupler User Manual Content Page INTRODUCTION... 1 Revision History... 2 Trademark Information... 2 Admonishments... 2 General Safety Precaution... 2 1

More information

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Traditional RF Splitter/Combiner and Directional Coupler User Manual Traditional RF Splitter/Combiner and Directional Coupler User Manual Content Page INTRODUCTION... 1 Revision History... 2 Trademark Information... 2 Admonishments... 2 General Safety Precaution... 2 1

More information

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual 24-Fiber LANLINXS (Model # 055-8632-5000) 48-Fiber LANLINXS (Model # 055-8832-5000) User Manual 24-Fiber LANLINXS (Model # 055-8632-5000) 48-Fiber LANLINXS (Model # 055-8832-5000) User Manual, Part Number

More information

CONNECTING THE FUTURE 19" LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL

CONNECTING THE FUTURE 19 LINXS LIGHTWAVE INTEGRATED CROSS-CONNECT SYSTEM USER MANUAL CONNECTING THE FUTURE 19" LINXS LIGHTWVE INTEGRTED CROSS-CONNECT SYSTEM USER MNUL 109003 Issue Rev 2 19" Lightwave Integrated Cross-Connect System (LINXS) User Manual Document Number 109003 Issue Rev 2

More information

Optical Distribution Box 300 Installation Guide. Version : R0.0

Optical Distribution Box 300 Installation Guide. Version : R0.0 Optical Distribution Box 300 Installation Guide Document No. : OD16-546-L-01 Version : R0.0 Date: 21-Mar-2018 IMPORTANT INSTRUCTIONS When using fiber optic equipment, basic precautions should always be

More information

Optical Component Environmental Test System

Optical Component Environmental Test System Data Sheet Optical Component Environmental Test System VIAVI Solutions The Certified VIAVI OCETS (Optical Component Environmental Test System) is the third generation of the classic OCETS, a solution customers

More information

OPTICAL FIBERCONNECT. Version 3.

OPTICAL FIBERCONNECT. Version 3. OPTICAL FIBERCONNECT Version 3. OPTICAL Fiberconnect intro In today s CATV networks the requirements for a wide choice of products for network applications are growing rapidly. In this brochure a comprehensive

More information

IP-LINX Fiber :: X-XXXX

IP-LINX Fiber :: X-XXXX Fiber :: 055-797X-XXXX User Manual Telect, Inc. All rights reserved. 146653-A0 Table of Contents Chapter 1: Introduction...3 1.1 Tools Required...3 1.2 Additional Parts...3 1.3 Assemblies...3 Chapter 2:

More information

Optimax Field Installable Connectors and Installation Tool Kits

Optimax Field Installable Connectors and Installation Tool Kits C O M M E R C I A L N E T W O R K I N G O P T I C A L F I B E R 16.4 FiberExpress Connectors Optimax Field Installable Connectors and Installation Tool Kits AX101982 Optimax LC connector Optimax Field

More information

Infinity Fibre Distribution Frame

Infinity Fibre Distribution Frame Infinity Fibre Distribution Frame C www.aflglobal.com/au www.aflglobal.com/nz Infinity Fibre Distribution Frame The Infinity Fibre Distribution Frame (IFDF) is a high density optical interconnect solution

More information

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box LANmark-OF Zone Distribution Box INSTALLATION GUIDE LANmark-OF Zone Distribution Box Document information Release November 2004 Published by Contact address Nexans Cabling Solutions Alsembergsesteenweg

More information

OptiTect Premier Local Convergence Cabinet An Evolant Solutions Product

OptiTect Premier Local Convergence Cabinet An Evolant Solutions Product Description The OptiTect Premier Local Convergence Cabinet family provides everything necessary to manage 44, 288 and 432 distribution fibers for an outside plant FTTx application. The OptiTect Premier

More information

Section Communications Optical Fiber Backbone Cabling

Section Communications Optical Fiber Backbone Cabling Part 1 1.1 Related Documents 1.1.1 Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specifications Sections apply to this Section. 1.2 Related

More information

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual

GF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual Instruction manual GF/KSW/48 Page Nr 1 GF-KSW-48 Series of Fiber Optic Distribution Box Instruction Manual 1. General Introduction GF-KSW-48 series of fiber optic distribution box is applicable to fiber

More information

Cable Installation Tips

Cable Installation Tips Cable Installation Tips Campus Network Design & Operations Workshop These materials are licensed under the Creative Commons Attribution-NonCommercial 4.0 International license (http://creativecommons.org/licenses/by-nc/4.0/)

More information

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12) FAML1UC0C OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12) Fiber Type Total Fibers, quantity 12 Cord Length, maximum 23 ft 7 m Cord Length,

More information

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published White Paper How to Specify MTP Pre-terminated Optical Cabling Published January 2009 The benefits of pre-terminated cabling The two principal advantages of pre- terminated cabling are reduced time on site

More information

HI-DEX PRODUCT SET DATASHEET

HI-DEX PRODUCT SET DATASHEET APPLICATION HI-DEX is an ultra high-performance, pre-terminated and modular optical fibre cabling system based on MT ferrule connector technology. This product set is designed for installationn in the

More information

Customer-Owned Outside Plant

Customer-Owned Outside Plant Customer Premises Products (Enterprise) 3 Customer-Owned Outside Plant Fiber Optic Splice Case 2178 Series and Accessories 372 Fiber Optic Dome Splice Closure FD Series 376 Fibrlok II Universal Optical

More information

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING SUMITOMO PRODUCT SPECIFICATION FutureFLEX TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100,

More information

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM Content 1. General 5 2. The products of NC-1000 system 6 3. Mounting of the frame 8 4. Earthing of the frame 8 NC-1000 FIBRE OPTIC

More information

about dktcomega DKTCOMEGA s mission

about dktcomega DKTCOMEGA s mission optical passives about dktcomega DKTCOMEGA designs optical and coaxial products for professional broadband operators and service providers. DKTCOMEGA s unique fibre optical product line, combined with

More information

2178 L/S Series Fiber Optic Splice Cases and Accessories

2178 L/S Series Fiber Optic Splice Cases and Accessories 2178 L/S Series Fiber Optic Splice Cases and Accessories The 3M 2178 Fiber Optic Splice Case family has always given you great protection for fiber optic connections. Now, the addition of 3M 2178-L/S Series

More information

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES SUMITOMO PRODUCT SPECIFICATION FutureFLEX TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100, Raleigh, NC 27610 (919) 541-8100

More information

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel 1993 Specifications CSJ 0924-06-223 SPECIAL SPECIFICATION 1160 8:1 Video (De) Mux with Data Channel 1. Description. This Item shall govern for furnishing and installing an 8 channel digital multiplexed

More information

DIGITAL DISTRIBUTING FRAME (DDF) INSTALLATION PROCEDURES FOR PANELS AND MODULES

DIGITAL DISTRIBUTING FRAME (DDF) INSTALLATION PROCEDURES FOR PANELS AND MODULES DIGITAL DISTRIBUTING FRAME (DDF) INSTALLATION PROCEDURES FOR PANELS AND MODULES CommScope 365-301-136-1 Instruction Sheet Issue 10, February 2004 Material ID 847 591 963 General The Digital Distributing

More information

SPECIFICATION FOR FIBER OPTIC SPLICE CLOSURE

SPECIFICATION FOR FIBER OPTIC SPLICE CLOSURE SP-CTN-CT3000M,CT3000ML-00 ISSUED : 2015/02/11 PAGE : 8 SPECIFICATION FOR FIBER OPTIC SPLICE CLOSURE CT3000M/CT3000ML Fiber Optic Splice Closure 2 / 8 1. GENERAL This specification covers the standards

More information

HighBand 25. TrueNet Category 6 Solutions

HighBand 25. TrueNet Category 6 Solutions HighBand 25 TrueNet Category 6 Solutions The highest performing cross-connect system in the world. A unique high-density solution with superior cable management. ADC KRONE s HighBand 25 cross connect solution

More information

Cable Installation Tips

Cable Installation Tips Cable Installation Tips Campus Network Design & Operations Workshop These materials are licensed under the Creative Commons Attribution-NonCommercial 4.0 International license (http://creativecommons.org/licenses/by-nc/4.0/)

More information

GATOR PATCH. The ultimate fiber distribution terminal

GATOR PATCH. The ultimate fiber distribution terminal The ultimate fiber distribution terminal PRODUCT OVERVIEW Rugged, Fast, Reliable! Trust the original Gator Patch for all your fiber distribution needs The Gator Patch is a unique, rugged, factory terminated

More information

HCS - HES Cabling Systems

HCS - HES Cabling Systems HCS - HES Cabling Systems Installation Manual for HCS High-Capacity Fiber-Optic Rack-Mount Cabinets Be sure to read and completely understand this procedure before applying product. Be sure to select the

More information

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011 SECTION 271323 - COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING PART 1 - GENERAL 1.1 DESCRIPTION A. This section provides the specifications for the work related to the optical fiber system in the project.

More information

SECTION 4 TABLE OF CONTENTS

SECTION 4 TABLE OF CONTENTS Contents Introduction LC, SC and ST Series...4-2 Markets and Applications...4-2 International Standard Documents Compliance...4-2 LC Series Features and Benefits...4-3 LC Standard... 4-4 to 4-5 LC for

More information

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division SPECIFICATION FIBER OPTIC SPLICE CLOSURE Model Spec. No. Distribution Depts. VSOF-BS403A VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division Sales Division Management Division Revision 10. 07 (Rev.4)

More information

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available Fiber Optic Products FIBER OPTIC PRODUCTS FIBER OPTIC PATCH CORD CABLE The Construction of a Fiber-Optic Cable Cable Jacket - The outermost layer of the fiber cable. Strengthening fibers - The strengthening

More information

OPTICAL DISTRIBUTION STATION -

OPTICAL DISTRIBUTION STATION - optical distribution station is a high performance, four individual outputs node. With high output levels and performance to 862MHz, it provides an ideal platform for support of the evolving technologies

More information

TRFM Series RF Amplifier Module

TRFM Series RF Amplifier Module Doc. 2272065, Rev. C TIARRA Optical Node TRFM Series RF Amplifier Module Contents Equipment Description... 39 Model Names... 41 Functional Description... 43 Return RF Signal Flow... 45 Controls and Connectors...

More information

CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories

CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories Evolution Cable Management Page 5-3 Velocity Cable Management Page 5-8 Velocity Standard Pack Page 5-12 Vertical Cable Management Page 5-13 Global

More information

Model GS Port Node 1 GHz with 65/86 MHz split

Model GS Port Node 1 GHz with 65/86 MHz split Model GS7000 4-Port Node 1 GHz with 65/86 MHz split The Model GS7000 4-Port Node is our latest generation 1 GHz optical node platform and utilizes a completely new housing designed for optimal heat dissipation.

More information

MTS/T-BERD Platforms WDMPMD Module

MTS/T-BERD Platforms WDMPMD Module ACTERNA TEST & MEASUREMENT SOLUTIONS MTS/T-BERD Platforms WDMPMD Module Key Features A unique solution combining OSA, PMD, and SA test functions in one plug-in module The most compact PMD/WDM/SA test solution

More information

3M Fiber Optic Wall Mount Enclosure 8430 Series

3M Fiber Optic Wall Mount Enclosure 8430 Series 3M Fiber Optic Wall Mount Enclosure 8430 Series Installation Instructions January 2014 3 78-0013-9429-1-A Table of Contents 1.0 Description...3 2.0 Parts...4 3.0 Assembly...4 4.0 Mounting the Enclosure...6

More information

ULTRA HIGH DENSITY SOLUTION GUIDE

ULTRA HIGH DENSITY SOLUTION GUIDE ULTRA HIGH DENSITY SOLUTION GUIDE About A global leader in fiber optic technology, AFL Hyperscale brings together over 70 years of design and manufacturing expertise to create next generation, end to

More information

3M 8900 Single-mode SC Crimplok Connector

3M 8900 Single-mode SC Crimplok Connector 3M 8900 Single-mode SC Crimplok Connector Technical Report June 1999 80-6110-1441-8 1 1.0 Product Description & Requirements The 3M SC Single-mode Crimplok Connector is designed to provide the customer

More information

DS3/STS-1 Repeater Products

DS3/STS-1 Repeater Products With over a decade of proven design and manufacturing expertise in the repeater market, ADC provides both the DS3 ntraoffice (R) and Bridging ffice Repeater (BR). Built for reliability, modularity and

More information

The FiberMark1 offers an ideal solution for

The FiberMark1 offers an ideal solution for Large Capacity Fiber Optic Splice Enclosure The Ideal Solution For Large Capacity Voice, Data, and Video Splicing Requirements. The FiberMark1 offers an ideal solution for larger fiber capacity voice,

More information

I/A Series Hardware Fiber Optic LAN Converter

I/A Series Hardware Fiber Optic LAN Converter I/A Series Hardware PSS 21H-7F3 B4 The provides bidirectional conversion between coaxial and fiber optic media. The converter is compatible with existing I/A Series system hardware, utilizes industry standard

More information

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES SUMITOMO PRODUCT SPECIFICATION FutureFLEX TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100, Raleigh, NC 27610 (919) 541-8100 or 1-800-358-7378

More information

Dual & Single Fiber DWDM Mux Demux

Dual & Single Fiber DWDM Mux Demux Data Center & Cloud Computing DATASHEET Dual & Single Fiber DWDM Mux Demux Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2018 DWDM Mux Demux 01 1 Introduction FS.COM designs and offers

More information

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

WaveTrax. Fiber Cable Management System

WaveTrax. Fiber Cable Management System Table of Contents Overview...3 Trough...4 Trough Cover...4 Trough Notching Tool...4 FastLock Coupler...4 Competitive FastLock Coupler...5 Horizontal Elbow...5 Horizontal Elbow Cover...5 Horizontal T...5

More information

SYSTIMAX Solutions InstaPATCH 360 Pre-Terminated Fiber Solution Guide

SYSTIMAX Solutions InstaPATCH 360 Pre-Terminated Fiber Solution Guide www.commscope.com SYSTIMAX Solutions InstaPATCH 360 Pre-Terminated Fiber Solution Guide Introduction The information in this solution guide will be instrumental in helping you determine the right products

More information

Fiber Optics Redefined

Fiber Optics Redefined Fiber Optics Redefined Questions and Answers on the basics of fiber optic installation TECHLOGIX NETWORX Questions & Answers Questions and Answers Q: What are the two main types of fiber? A: The two main

More information

Keyed LC Connector Solution A LANscape Solutions Product

Keyed LC Connector Solution A LANscape Solutions Product Applications Department of Defense installations Secure government facilities Research labs Organizations with a desire to segregate networks due to privacy or security concerns Keyed LC Connector Solution

More information

Follow The Leader In Shielded Technology

Follow The Leader In Shielded Technology 1970s Vampire Tap 1990s Shielded Modular Jack 190s 4 Position Data Connector Follow The Leader In Shielded Technology The new AMP-TWIST Jack is our latest shielded product evolution. It can be terminated

More information

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products MT-RJ Product Expansion Now 0 Variants of the MT-RJ Products In response to several customers, the MT-RJ product line has been expanded with an additional six color/key versions. In addition to the original

More information

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE Prepared in cooperation and approval from BICSI Building Industry Consulting Services International and

More information

Preferred ordering guide for NETCONNECT

Preferred ordering guide for NETCONNECT Preferred ordering guide for NETCONNECT MEA Region Contents Copper solutions Category 6A products 3 Category 6A and Category 7 shielded copper cables 3 Category 6A modular shielded panels 3 Category 6A

More information

EZ-MATE CONNECTORS The Complete Family of Multi-Channel Fiber Optic Connectors for Harsh Environment Deployable Systems

EZ-MATE CONNECTORS The Complete Family of Multi-Channel Fiber Optic Connectors for Harsh Environment Deployable Systems The Complete Family of Multi-Channel Fiber Optic Connectors for Harsh Environment Deployable Systems Overview The OCC EZ-MATE family of hermaphroditic style fiber optic connectors provides the most comprehensive

More information

DS1 Cross-Aisle Panel

DS1 Cross-Aisle Panel DS1 Cross-Aisle Panel Model 005-0005-0100 Installation Guide 1.1 Overview 1.1.1 Inspection Compare the contents of the DS1 Cross-Aisle Panel shipping container with the packing list. Call Telect if anything

More information

Prisma Optical Networks Ancillary Modules

Prisma Optical Networks Ancillary Modules Optoelectronics Prisma Optical Networks Ancillary Modules Description The Prisma platform is capable of utilizing a combination of modules which address a variety of revenue generating applications. The

More information

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1 Modular Solutions Subject to technical changes! 1 Since 1986, braun telecom has stood for continuity and competence in broadband communication and has become one of the leading suppliers of products and

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION (FIBER OPTIC SPLICE CLOSURE) Model Spec. No. Distribution Depts. VSOF-BS403A SJP-0609-403A-01A/SD Quality Assurance Team Manufacturing Division Sales Division Management Division

More information

OTS-300 Express Series Power Meters/Sources and Testers

OTS-300 Express Series Power Meters/Sources and Testers OTS-300 Express Series includes intelligent, versatile optical meters, sources, and testers that simultaneously test and store dual wavelength attenuation measurements. At the press of a button, dual wavelength

More information

Camera Control Unit 55D-BS VOLUME OPEN CABLE MIC OFF GND 2W CAMERA CABLE TALLY. Camera Adapter 55D-CA 9.39" 7.40" 5.2"

Camera Control Unit 55D-BS VOLUME OPEN CABLE MIC OFF GND 2W CAMERA CABLE TALLY. Camera Adapter 55D-CA 9.39 7.40 5.2 The Telemetrics Coax/Fiber Link is an affordable camera control system with increased operating distance. Using frequency multiplexing the following signals are transmitted over a single coaxial cable:

More information

Broadband Connectivity System II

Broadband Connectivity System II User Manual Applys to: :: 010-3232-0001 :: 010-3224-0001 :: 010-3201-0407 :: 010-3201-0401 :: 010-3201-0410 :: 710-3201-0002 :: 710-3201-0005 :: 710-3201-1001-U :: 710-3201-1002-U :: 710-3201-2001-U ::

More information

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

SPECIAL SPECIFICATION 6735 Video Optical Transceiver 2004 Specifications CSJ 0924-06-244 SPECIAL SPECIFICATION 6735 Video Optical Transceiver 1. Description. This Item governs the furnishing and installation of Video optical transceiver (VOTR) in field location(s)

More information

SPECIAL SPECIFICATION 6559 Telecommunication Cable

SPECIAL SPECIFICATION 6559 Telecommunication Cable 2004 Specifications CSJ 0015-09-147, etc. SPECIAL SPECIFICATION 6559 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing, training,

More information

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING SUMITOMO PRODUCT SPECIFICATION FutureFLEX TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100, Raleigh, NC 27610

More information

Cisco ONS Exposed Faceplate Mux/Demux 48-Channel Extended Bandwidth Patch Panel and Splitter Coupler Module

Cisco ONS Exposed Faceplate Mux/Demux 48-Channel Extended Bandwidth Patch Panel and Splitter Coupler Module Cisco ONS 15216 Exposed Faceplate Mux/Demux 48- Extended Bandwidth Patch Panel and Splitter Coupler Module Product Overview The Cisco ONS 15216 Exposed Faceplate Mux/Demux 48- Extended Bandwidth Patch

More information

Belden. Optical Fiber Catalog. Belden FiberExpress Systems, Cable and Connectivity

Belden. Optical Fiber Catalog. Belden FiberExpress Systems, Cable and Connectivity Belden Optical Fiber Catalog Belden FiberExpress Systems, Cable and Connectivity Belden FiberExpress Systems are the definitive choice for all your optical fiber needs. Our focus on quality and detail

More information

Simple View TM. From the beginning to the end. We leave nothing out when it comes to your satisfaction.

Simple View TM. From the beginning to the end. We leave nothing out when it comes to your satisfaction. Simple View TM From the beginning to the end. We leave nothing out when it comes to your satisfaction. We are currently developing eco-friendly and high-quality products to meet the respective needs of

More information

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12 Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12 Our I-IFLRF20 series is a wideband RF over fiber link that provides optical transport of RF signals in radars, satcom, EW/ECM and other antenna remoting

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE STANDARD SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE STANDARD SCTE ENGINEERING MITTEE Interface Practices Subcommittee SCTE STANDARD SCTE 240 2017 SCTE Test Procedures for Testing CWDM Systems in Cable Telecommunications Access Networks NOTICE The Society of Cable Telecommunications

More information

Connectivity accessories by Nestor Cables

Connectivity accessories by Nestor Cables Connectivity accessories by Nestor Cables NesCon product family includes essential installation and connection accessories for fibre optic networks, from ODFs to joint closures and terminations. www.nestorcables.com

More information

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15

FOSC 400. Ordering Guide For Closures and Accessories. Section I 3. Section II 5. Section III 9. Section IV 11. Section V 15 FOSC 400 Ordering Guide For Closures and Accessories Section I 3 How to Order FOSC 400 Closures Section II 5 How to Order Accessories for FOSC 400 Closures Section III 9 Other FOSC Fiber Optic Splice Closures

More information

SPECIAL SPECIFICATION 8540 Telecommunication Cable

SPECIAL SPECIFICATION 8540 Telecommunication Cable 2004 Specifications CSJ 0914-00-307 & CSJ 0914-25-003 SPECIAL SPECIFICATION 8540 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing,

More information

Cisco GS7000 High-Output 4-Way Segmentable Node with 42/54 Split

Cisco GS7000 High-Output 4-Way Segmentable Node with 42/54 Split Data Sheet Cisco GS7000 High-Output 4-Way Segmentable Node with 42/54 MHz Split The Cisco GS7000 High-Output Segmentable Node with 42/54 MHz Split is the latest-generation 1-GHz optical node platform designed

More information

Datasheet: SimpliFiber Pro

Datasheet: SimpliFiber Pro Datasheet: SimpliFiber Pro Datasheet: SimpliFiber Pro SimpliFiber Pro makes testing simple Fluke Networks' SimpliFiber Pro Optical Power Meter incorporates new and innovative features to give technicians

More information

AMERICAN NATIONAL STANDARD

AMERICAN NATIONAL STANDARD Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 129 2017 Drop Passives: Bonding Blocks (Without Surge Protection) NOTICE The Society of Cable Telecommunications Engineers (SCTE) Standards

More information

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting) 2004 Specifications CSJ 0086-14-046 SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting) 1. Description. Furnish, install, splice, field terminate, and test the fiber optic cables. 2. Materials.

More information

Seal Kits for BUDI Enclosures

Seal Kits for BUDI Enclosures Description BUDI is a product range of compact, wall mountable fiber enclosures for indoor and outdoor use. They are specifically designed for fast deployment and easy customer connection. The FIST management

More information

ChromaFlex. ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules HARDWARE INTERFACE MANUAL.

ChromaFlex. ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules HARDWARE INTERFACE MANUAL. ChromaFlex ChromaFlex CF-QRRX Quad Analog Return Path Receiver Modules HARDWARE INTERFACE MANUAL www.atxnetworks.com www.atxnetworks.com Although every effort has been taken to ensure the accuracy of this

More information

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

SPECIAL SPECIFICATION 6191 Fiber Optic Cable 2004 Specifications CSJ 0014-02-014, etc SPECIAL SPECIFICATION 6191 Fiber Optic Cable 1. Description. Furnish, install, splice, field terminate, and test the fiber optic cables. 2. Materials. A. General

More information

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017 Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM-2017-2 Date: 05/26/2017 Additional specification information for data communication to cameras and between Library

More information

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter Fully compliant to LXI Class C specification General Information Up to 8 power meter channels in a

More information

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules MTS/T-BERD platform Applications Provisioning and maintenance of ROADM networks Commissioning of DWDM

More information

RACKS, ENCLOSURES AND CABLE MANAGEMENT

RACKS, ENCLOSURES AND CABLE MANAGEMENT and RS3 RACK SYSTEM (pages 6.2 6.3) RS RACK SYSTEM (pages 6.4 6.5) EXTENDED DEPTH RS RACK SYSTEM (page 6.5) Vertical Side Rail Capacity Cable Manager Covers Accessories 117mm x 152mm (4.6 in. x 6.0 in.)

More information

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1993 Specifications CSJ 0500-01-117 SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic Video

More information

DWDM. DATA SHEET DB4134-E Issue F Page 1 of 6

DWDM. DATA SHEET DB4134-E Issue F Page 1 of 6 DWDM DATA SHEET DB4134-E Issue F Page 1 of 6 Passive optical multiplexer/de-multiplexer. Increases the capacity of existing networks by transferring several wavelengths on the same fibre. Independent of

More information

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 2004 Specifications CSJ 3256-02-079 & 3256-03-082 SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 1. Description. Furnish and install Fiber Optic Video Data Transmission Equipment

More information