Section B Fibre Optic Connection Systems

Size: px
Start display at page:

Download "Section B Fibre Optic Connection Systems"

Transcription

1 Section B Fibre Optic Connection Systems Fibre Optic Leads and Modes Explained Fibre Optic Patch Leads Fibre Optic Pigtails Fibre Optic Connectors and Couplers Fibre Optic Connector Accessories Fibre Optic Tools Fibre Optic Testers Fibre Structured Cabling Systems B2 - B3 B4 - B6 B7 B8 B9 - B10 B11 B12 B13 - B14

2 Fibre Optic Leads & Modes Explained Transmission Distances with Differing Fibre Optic Cable There are a number of different fibre types, and transmission modes, and in the tables below you will find explanations of some of the fibre optic terminology Multi-Mode Single-Mode Type OM1 OM2 OM3 OS1 Diameter 62.5/125µm 50/125µm 50/125µm 9/125µm 100Mb Fast Ethernet 300m (850nm) 100Base-SX 2km (1310nm) 100Base-FX 300m (850nm) 100Base-SX 2km (1310nm) 100Base-FX 300m (850nm) 100Base-SX 2km (1310nm) 100Base-FX 2km (1310nm) 100Base-FX Fibre Optic Leads & Modes Explained 1 Gigabit Ethernet 275m (850nm) 1000Base-SX 550m (1310nm) 1000Base-LX* 10 Gigabit Ethernet 33m (850nm) 10GBase-SR 300m (1300nm) 10GBase-LX4* 550m (850nm) 1000Base-SX 550m (1310nm) 1000Base-LX* 82m (850nm) 10GBase-SR 300m (1300nm) 10GBase-LX4* 2km (850nm) 1000Base-SX 550m (1310nm) 1000Base-LX 300m (850nm) 10GBase-SR 300m (1300nm) 10GBase-LX4 10km 20km (1310nm) 1000Base-LX/LH 20km 100km (1550nm) 1000Base-LX/LH 10km (1310nm) 10GBase-LR 10km (1310nm) 10GBase-LX4 These are guidelines only; every manufacturer's cable differs so there are variations in performance. Please check cable specifications if in doubt. * Mode Conditioning Patch Cable Required Fibre Optic Cables - OM1, OM2, OM3 and OS1 Explained Multi-Mode - OM Optical Multi-Mode OM stands for Optical Multi-Mode. There are several different classes of Multi-Mode Fibre Optic Cable available: OM1 - This is very much the original optical fibre that has been used for the past number of years. This is 62.5µm optical fibre. OM2 - This is 50µm fibre with Overfilled Launch Bandwidth of 500MHz/Km. The applications will support Gigabit networks up to 550 metres. OM3 - This is essentially the new Laser Optimised Fibre with refractive index profile optimised for laser light 850nm, and is targeted at 10G. OM3 optical fibre systems are the pinnacle of Multi-Mode fibre design. To utilise the new 10Gbs Ethernet protocols in an optical fibre system requires the use of either a full blown single mode solution or OM3 50/125 Multi-Mode cable. The OM3 system allows for new VCSEL laser based hardware and old legacy LED based hardware to co-exist over one system, providing a simple migration path through from 10Mb to 10Gbs and the security knowing the system you are installing today will give many years of solid, secure service to your network. OM2 fibre can support 1Gbps transmission speeds over distances of about 550m, but OM3 can achieve 800m; the increase is even more significant for 10Gb, increasing from 82m for OM2 to 300m for OM3. Single-Mode - OS Optical Single-Mode OS1. This is single mode 9/125µm fibre and is the highest performance cable which is generally used for Telecom s and campus networks. OS1 fibre requires laser based hardware and can support high data rates over very long distances. Fibre Optic Data Propagation Modes Fast Ethernet 100Base-SX 100Mbps 850nm LED Short Wave 100Base-FX 100Mbps 1310nm LED Long Wave Length One Gigabit Ethernet 1000Base-SX 1000Mbps 850nm LASER Short Wave Length 1000Base-LX 1000Mbps 1310nm LASER Long Wave Length 1000Base-LX/LH 1000Mbps 1310nm LASER Long Wave Length/Long Haul Single Mode 1000Base-LX/LH 1000Mbps 1550nm LASER Extra Long Wave Length/Long Haul Single Mode Ten Gigabit Ethernet 10GBase-SR 10Gbps 850nm LASER Short Wave Length 10GBase-LR 10Gbps 1310nm LASER Long Wave Length 10GBase-LX4 10Gbps 1300nm(MM), 1310(SM) LASER Long Wave Length B2 sales@cabac.com.au

3 Fibre Optic Leads & Modes Explained MULTI - MODE Multi-mode Fibre has light travelling in the core in many rays, called modes. It has a bigger core (62.5µm / 50µm) and is used with LED sources at wave lengths of 850nm and 1300nm and lasers at 850nm and 1310nm HALF DUPLEX A signalling system whereby transmission can occur in both directions, but in only one direction at a time. A good example of this is a walkie talkie conversation between two people. One has to tell the other they are finished speaking, or over to you. SINGLE - MODE Single-mode Fibre has a much smaller core, only about 9 microns, so that the light travels in only one ray or mode. It is used with laser sources at 1310nm and 1550 nm. FULL DUPLEX A method where transmission can take place in both directions at the same time An example of full duplex transmission is a telephone conversation, as both participants can talk and listen at the same time without waiting for the other to finish. Fibre Optic Leads & Modes Explained MODE CONDITIONING LEADS When using multi-mode 62.5/125µm optical fibre for transmitting Gigabit data over distances greater than 300 metres, a Mode Conditioning Patch cord must be used at each transmitter/receiver. This is because when a laser is launched into the centre of a multi-mode fibre it may cause differential mode delay (DMD) effects that generate multiple signals. The Mode Conditioning Patch cord overcomes this problem by launching the laser light from the transmitter into a single mode fibre which is aligned with a precise offset from the centre of the core of a 62.5/125µm fibre in the mode conditioning part of the patch cord. The output from the patch cord is then compliant with the standard for 1000Base-LX. Mode Conditioning Patch Cords are not recommended for short transmission distances - a few tens of metres - as bit errors may occur/increase. Phone: Fax: B3

4 Fibre Optic Patch Leads single-mode & MULTI-MODE All leads are manufactured from Dow Corning Fibre, for consistent quality UL approved cables Individually labelled for lead tracing All leads are supplied with a factory test report All ends are polished and individually inspected for correct polishing Manufactured with stringent quality control Lead specifications OM1 OM2 OS1 Multi-Mode Multi-Mode Single-Mode Fibre Diameter 62.5µm 50µm 9µm Buffer Diameter 125µm 125µm 125µm Connector Colour Beige Beige Blue Longer or special leads can be made to order, please contact CABAC sales SC to SC Connectors Fibre Optic Patch Leads Multi-Mode Multi-Mode Single-Mode OM1-62.5µm OM2-50µm OS1-9µm 45FSCD1M 45FSCD1M50UM 45FSCD1MS 1m 45FSCD2M 45FSCD2M50UM 45FSCD2MS 2m 45FSCD3M 45FSCD3M50UM 45FSCD3MS 3m 45FSCD5M 45FSCD5M50UM 45FSCD5MS 5m 45FSCD10M 45FSCD10M50UM 45FSCD10MS 10m 45FSCD15M 45FSCD15M50UM 45FSCD15MS 15m 45FSCD20M 45FSCD20M50UM 45FSCD20MS 20m ST to ST Connectors Multi-Mode Multi-Mode Single-Mode OM1-62.5µm OM2-50µm OS1-9µm 45FSTD1M 45FSTD1M50UM 45FSTD1MS 1m 45FSTD2M 45FSTD2M50UM 45FSTD2MS 2m 45FSTD3M 45FSTD3M50UM 45FSTD3MS 3m 45FSTD5M 45FSTD5M50UM 45FSTD5MS 5m 45FSTD10M 45FSTD10M50UM 45FSTD10MS 10m 45FSTD15M 45FSTD15M50UM 45FSTD15MS 15m 45FSTD20M 45FSTD20M50UM 45FSTD20MS 20m SC ST SC ST ST to SC Connectors Multi-Mode Multi-Mode Single-Mode OM1-62.5µm OM2-50µm OS1-9µm 45FSTSCD1M 45FSTSCD1M50UM 45FSTSCD1MS 1m 45FSTSCD2M 45FSTSCD2M50UM 45FSTSCD2MS 2m 45FSTSCD3M 45FSTSCD3M50UM 45FSTSCD3MS 3m 45FSTSCD5M 45FSTSCD5M50UM 45FSTSCD5MS 5m 45FSTSCD10M 45FSTSCD10M50UM 45FSTSCD10MS 10m 45FSTSCD15M 45FSTSCD15M50UM 45FSTSCD15MS 15m 45FSTSCD20M 45FSTSCD20M50UM 45FSTSCD20MS 20m ST SC MTRJ to MTRJ Connectors Multi-Mode OM1-62.5µm 45MTRJ1M 45MTRJ2M 45MTRJ3M 45MTRJ5M 45MTRJ10M 45MTRJ15M 45MTRJ20M 1m 2m 3m 5m 10m 15m 20m MTRJ MTRJ B4 sales@cabac.com.au

5 Fibre Optic Patch Leads MTRJ to SC Connectors Multi-Mode OM1-62.5µm 45MTRJSC1M 45MTRJSC2M 45MTRJSC3M 45MTRJSC5M 45MTRJSC10M 45MTRJSC15M 45MTRJSC20M 1m 2m 3m 5m 10m 15m 20m single-mode & MULTI-MODE MTRJ SC MTRJ to ST Connectors Multi-Mode OM1-62.5µm 45MTRJST1M 45MTRJST2M 45MTRJST3M 45MTRJST5M 45MTRJST10M 45MTRJST15M 45MTRJST20M 1m 2m 3m 5m 10m 15m 20m LC to LC Connectors Multi-Mode Multi-Mode Single-Mode OM1-62.5µm OM2-50µm OS1-9µm 45FLCD1M 45FLCD1M50UM 45FLCD1MS 1m 45FLCD2M 45FLCD2M50UM 45FLCD2MS 2m 45FLCD3M 45FLCD3M50UM 45FLCD3MS 3m 45FLCD5M 45FLCD5M50UM 45FLCD5MS 5m 45FLCD10M 45FLCD10M50UM 45FLCD10MS 10m 45FLCD15M 45FLCD15M50UM 45FLCD15MS 15m 45FLCD20M 45FLCD20M50UM 45FLCD20MS 20m MTRJ LC ST LC Fibre Optic Patch Leads Phone: Fax: B5

6 Fibre Optic Patch Leads LC to SC Connectors Multi-Mode Multi-Mode Single-Mode OM1-62.5µm OM2-50µm OS1-9µm 45FLCSCD1M 45FLCSCD1M50UM 45FLCSCD1MS 1m 45FLCSCD2M 45FLCSCD2M50UM 45FLCSCD2MS 2m 45FLCSCD3M 45FLCSCD3M50UM 45FLCSCD3MS 3m 45FLCSCD5M 45FLCSCD5M50UM 45FLCSCD5MS 5m 45FLCSCD10M 45FLCSCD10M50UM 45FLCSCD10MS 10m 45FLCSCD15M 45FLCSCD15M50UM 45FLCSCD15MS 15m 45FLCSCD20M 45FLCSCD20M50UM 45FLCSCD20MS 20m LC SC LC to ST Connectors Fibre Optic Patch Leads Multi-Mode Multi-Mode Single-Mode OM1-62.5µm OM2-50µm OS1-9µm 45FLCSTD1M 45FLCSTD1M50UM 45FLCSTD1MS 1m 45FLCSTD2M 45FLCSTD2M50UM 45FLCSTD2MS 2m 45FLCSTD3M 45FLCSTD3M50UM 45FLCSTD3MS 3m 45FLCSTD5M 45FLCSTD5M50UM 45FLCSTD5MS 5m 45FLCSTD10M 45FLCSTD10M50UM 45FLCSTD10MS 10m 45FLCSTD15M 45FLCSTD15M50UM 45FLCSTD15MS 15m 45FLCSTD20M 45FLCSTD20M50UM 45FLCSTD20MS 20m FC to FC Connectors Multi-Mode OM1 45FFCD1M 45FFCD2M 45FFCD3M 45FFCD5M Single-Mode OS1 45FFCD1MS 45FFCD2MS 45FFCD3MS 45FFCD5MS LC ST 45FFCD1M FC to LC Connectors Multi-Mode OM1 45FFCLCD1M 45FFCLCD2M 45FFCLCD3M 45FFCLCD5M Single-Mode OS1 45FFCLCD1MS 45FFCLCD2MS 45FFCLCD3MS 45FFCLCD5MS 45FFCLCD1M B6

7 Single Lead Pigtails µm Pigtails are a pre-terminated and tested single ended fibre lead, which are spliced onto fibre cable runs They are generally installed in a fibre tray/patch panel assembly, with the connector of the pigtail being inserted in an adaptor on the patch panel This eliminates connector installation in the field 45FP9SC2M which has major issues with regard to quality control and testing Saves time in installing structured fibre systems 45FP9ST2M Splicing in the field is very reliable and easy to test Outside diameter of fibre jacket is 900µm Inner fibre diameter - Single-Mode 9µm - Multi-Mode 62.5µm Multi-Mode Single-Mode 45FP9SC2M 45FP9SC2MS SC 45FP9ST2M 45FP9ST2MS ST Fibre Optic Pigtails single-mode & MULTI-MODE Pigtails - Colour Coded Pack of 6 or 12 These packs of 12 colour coded pigtail leads are used in patch panel terminations, with the fibre end of the pigtail being spliced onto the fibre run, and the connector being inserted in a coupler/adaptor on the patch panel The colours are the same as international standard multi-core fibre cables The connector on the pigtail has been pre-tested and certified in a controlled environment This eliminates connector installation in the field which has major issues with regard to quality control and testing Saves time in installing structured fibre systems Splicing in the field is very reliable and easy to test Outside diameter of fibre jacket is 900µm Inner fibre diameter - Single-Mode 9µm - Multi-Mode 62.5µm Fibre Optic Pigtails 6 Pack Multi-Mode Single-Mode OM1-62.5µm OS1-9µm 45FP9SC6CC 45FP9SC6S SC 45FP9ST6CC 45FP9ST6S ST 12 Pack Multi-Mode Single-Mode OM1-62.5µm OS1-9µm 45FP9SC12CC 45FP9SC12S SC 45FP9ST12CC 45FP9ST12S ST 45FP9SC12CC 45FP9ST12CC Phone: Fax: B7

8 Fibre Optic Connectors & Couplers Fibre Connectors for 50µm and 62.5µm Fibres Connectors are designed for standard fibre - Single-Mode 9/125µm - Multi-Mode 50/125µm and 62.5/125µm - Jacket diameter 3mm for ST, SC and MTRJ, 2.4mm for LC See connector assembly equipment pages B8 to B12 Use the 45CTRLF tool to crimp Low insertion loss Multi-Mode Single-Mode 45PSTMMZ 45PSTSMZ ST 45PSCMMZ 45PSCSMZ SC 45PLCMM 45PLCSM LC 45PMTRJMM 45PMTRJSM MTRJ 45PSCMMZ 45PSTMMZ Fibre Optic Connectors & Couplers Fibre Couplers & Adaptors for 50µm and 62.5µm Connectors Multi-Mode sleeves are phosphor bronze Single-Mode sleeves are ceramic Flange style for panel mounting Fit in standard CABAC fibre trays Note LC and MTRJ Connectors have same Footprint as SC Simplex Couplers Multi-Mode Single-Mode Type Footprint 45CSTM 45CSTS ST Simplex ST Simplex 45CSCM 45CSCS SC Simplex SC Simplex 45CSCMDUP 45CSCSDUP SC Duplex SC Duplex 45CLCDUP 45CLCDUPS LC Duplex SC Simplex 45CMTRJDUP 45CMTRJDUP MTRJ Duplex SC Simplex Hybrid Adaptors Multi-Mode Single-Mode Type Footprint 45ASCSTMFL SC-ST Simplex SC Simplex 45ASCSTMD 45ASCSTSD SC-ST Duplex SC Duplex 45CSTM 45CSCM 45CLCDUP 45CMTRJDUP 45ASCSTMD 45ASCSTMFL 45CSCMDUP B8 sales@cabac.com.au

9 Fibre Optic Connector Accessories Epoxy Low viscosity Blue expoxy for easy of polishing Pot life 30min Ambient cure 24 hours at 25 C Oven cure - 2 hours at 65 C or 10 minutes at 110 C Two gram packet does approximately 10 terminations 45EPOXY2 45EA3ML Epoxy 2g Epoxy Syringe 3ml Blunt Tip 45EPOXY2 45EA3ML Connector Curing Oven - 24 Position Specially designed to cure epoxy in fibre optic connectors Supplied with 24 position holding block which will cure FC, SC, ST, D4, LC and SMA connectors A thermometer is included with every oven 45OV24 Canned Air, Disposable Unit Canned air removes particles from inaccessible areas Supplied with an extension nozzle Please Note: Can not be air freighted. 45CAIR Canned Air Dusting Gas Cleaning Tissues and Alcohol Wipes 280 lint free tissues, used with alcohol for cleaning fibre and connector The pre - moistened alcohol wipes, moistened with isopropyl alcohol, are ideal for cleaning connector ends and bare fibre 45KIMWIPES Fibre Cleaning Tissues 45WIPE Alcohol Wipes Pack of WIPE Fibre Optic Connector Accessories 45KIMWIPES Pucks Hand polishing of fibre optic connectors requires a precision tool Metal pucks are recommended for a precision finish 45PTSCM SC 45PTSTM ST 45PTSCM Phone: Fax: B9

10 Fibre Optic Connector Accessories Lapping Film Use lapping film to get optimum connector polish Diamond abrasive grade film Sheets will polish approximately 20 connectors per sheet Place film on a hard flat surface (hardened glass) while polishing 45LFA LFA41 45LFA43 45LFA45 45LFA412 45LFSMA4 Lapping Film A4 0.3µm, white Lapping Film A4 1µm, green Lapping Film A4 3µm, pink Lapping Film A4 5µm, brown Lapping Film A4 12µm, yellow Polishing Film Single-Mode Final Fibre Optic Connector Accessories Microscope This inspection microscope is a professional unit with coaxial illumination, making inspection easier Magnification is 200 times Uses white LED for illumination to extend battery and bulb life Has laser safety filters included Universal adaptor for ST, SC and FC LC and MTRJ adaptors available on request Takes three AAA batteries which provide 40 hours of use 45MSK1 Micro Fibre Stripper Easy to handle. Set adjustable strip length stop and insert optical cable. Squeeze handles together and withdraw cable Blades ground to laboratory accuracy and specially hardened Strips buffer from Multi-Mode fibre Adjustable stripping length setting Strip range 0.18 to 0.3mm KUS9 Fibre Optic Stripper Multi-function stripper for fibre Strips the outer jacket Strips the buffering from 250µm or 125µm fibre The tool is adjustable so that intermediate sizes can be accommodated Precision ground from carbon steel and hardened 45FC250 Fibre Cable and Jacket Stripper Ideal for fibre jacket and cable cutting and stripping Strips 0.25 and 0.32mm diameter fibre Strips 2.8 to 5.8mm jacket diameter Body is made from unbreakable ABS KFOST B10 sales@cabac.com.au

11 Fibre Optic Tools Fibre Scriber Quality carbide scribe offering a wide cutting surface Housed in a metal pen style enclosure 45SCRIBER Fibre Cleave Tool Rugged and reliable with a simple design Cleaves single-mode and multi-mode fibres to desired length Ceramic blade performs 6000 plus cleaves, performing 90% of cleaves within 1 Suitable for mechanical splicing with 99% of cleaves within 2 Easy to use and preferred by many installers 45CLEAV1 Fibre Crimp Tool Crimps standard epoxy based ST/SC/SMA connectors Hardened precision die Tool has four crimp positions: - Hexagonal 3.8mm (0.151") 3.25mm (0.128") - Round 4.8mm (0.190") 3.5mm (0.137") Ratchet ensures complete crimp 45CRTLF Industrial Scissors for Kevlar Designed to cut Kevlar when preparing fibre termination High quality serrated steel construction Ergonomic plastic handles Ultra hard jaw for long life KSCIS Fibre Optic Tools Fibre Optic Connector Installer Kit This kit contains all tools required for fibre optic termination Contents include: - Fibre scriber (45SCRIBER) - Two syringes - Fibre stripper (45FC250) - Isopropyl alcohol cleaning liquid - Epoxy glue and hardener - Polishing pucks for SC and ST fibre - Fibre cleaning tissues - Industrial scissors for Kevlar (KSCIS) - Hardened glass polishing plate - Crimp tool for fibre connectors (45CRTLF) - Three grades of lapping film: - 6µm - Brown - Diamond - 1µm - Purple - Diamond µm - White - Aluminium Oxide - Polish - Rubber working pad FIBREKIT4 Phone: Fax: B11

12 Fibre Optic Testers Fibre Checker Pro Instantly find breaks in single and multi-mode fibres Unit sends a visual red laser through the cables, and the fault causes refraction, causing a bright glow around the fault area It has a universal connector for ST, SC, FC, FDDA and LC using supplied adaptor Wavelength 650nm, <10nm spectral width, visibility up to 3Km Power output <5mW, continuous or pulse Dust proof design keeps connector clean FC-2005A Fibre Optic Testers Pocket Fault Locator This pocket sized tester sends a visible red laser light through the fibre optic cables Breaks or faults in the fibre will refract the light, creating a bright glow around the faulty area The universal connector can be used for most commonly used fibre interfaces Wave length 635±5nm Power 0.5 to 1mW FC2001 Fibre Optic Test Set - Multi-Mode A complete test set, with a light source and power meter Designed for multi-mode testing with 850nm and 1300nm wave length Signal power 10µW/-20dBm Automatically calculates the signal attenuation and displays actual received signal power A manual calibration ability to receive up to 65µW from industry standard Simultaneously displays the results in two different units (µw and dbm) Tests a wide range of measurements to µW and -60 to 10dBm Display accuracy to third decimal Tests varying cable diameters 50, 62.5, 100µm Clear LCD display with backlight ST connection types only Low battery indicator, 9V battery Fibre Optic Power Meters - Low Cost - Pen Style Infrared power meter for checking the signal power output of optical equipment in a fibre optic network Pen sized unit, will fit in your top pocket Has a double digit LED display of power Available in a single-mode or multi-mode as separate units Universal connector for ST/SC/FC/FDDA with optional 2.5 to 1.25mm adaptor Wave length - Multi-Mode - Model , 850nm and 1300nm - Single-Mode - Model , 1330nm and 1550nm Power range - Multi-Mode - Model , -30dBm to -15dBm - Single-Mode - Model , -30dBm to -6dBm Display is shown in -1dBm Has a Lo and Hi display if power is out of range Low battery display batteries AAA 1.5V by 2 Has a dustproof cover keeping connector clean Multi-Mode Single-Mode B12 sales@cabac.com.au

13 Fibre Structured Cabling Systems Splice Protectors Heatshrink sleeves with metal rod inserted for reinforcing Give good support to splices, once they are shrunk onto the fibre Designed to snap into the 45SPF tray Length 60mm 45FUSP Splice Tray Cassette Splice protectors snap into the splice trays Mount using two bolt holes Keeps fibre splices in a structured system Tray has two sets of six splice holders total 12 Trays can be stacked for large installations 45SPF 19" Fibre Patch Panel with Fibre Management Simple one piece fixed tray Rugged metal construction, painted black Tray portion has slots so fibre loops can be attached Compact 1RU design Compact 24 port front panel 43FTSC24 43FTST24 SC ST Rack Mount Fibre Tray - Unique Swing Away Type - 12 or 24 Port A novel design from CABAC, for 19 rack mounted tray Tray rotates out from the rack, giving quick and easy access to the tray area Fibre cable is permanently fixed, unlike sliding tray units Adaptor plates for differing connector types are attached to the front of the tray Can be 12 or 24 Port depending on the adaptor plates used Meets class 2 laser when angled adaptor plates are used, and patch cord cover is in place Supplied with cable ties for fibre management FTRM Fibre Structured Cabling Systems Supplied without adaptor plates Please See Page B14 for Details Phone: Fax: B13

14 Fibre Structured Cabling Systems Wall Mount Fibre Patch Panel - 12 or 24 Port Surface mount box for fibre termination and patching Includes a fibre management tray, with cable ties Differing adaptor plates (not supplied) must be fitted dependant on connectors used - see adaptor plates below Has a handy hinged lid and built-in fibre management Can be 12 or 24 port depending on adaptor plates used Meets Class 2 laser standard when used with Angled Adaptor Plates, Adaptor Kits and supplied Patch Cord Minder KTWM Fibre Structured Cabling Systems Fibre Adaptor Plates - For Patch Panels and Wall Cabinets Supplied in sets of two, and fit in the Patch Panels or Fibre Cabinets They are angled to meet Class 2 Laser Products Standard Fibre connectors are not supplied ST Simplex 52STAP12 12 Port 52STAP24 24 Port SC Simplex / LC Duplex / MTRJ Duplex 52SCAP12 12 Port 52SCAP24 24 Port SC Duplex 52SCAPD12 12 Port 52SCAPD24 24 Port Optic Fibre Marker Tape Used to mark the position of fibre cables underground, by laying the tape in the backfill to warn excavator operators White in colour to comply with the Australian standard for optic cables Metal detectable version has metal wire embedded so it is detectable Rolls are 250m long High chemical resistance Made from lead free material Australian approved product to AS2648 part WMTOF WMTOFD Non-Detectable Detectable ST Adaptor plate SC, LC, MTRJ Adaptor plates WMTOFD B14 sales@cabac.com.au

Fiber Optics Redefined

Fiber Optics Redefined Fiber Optics Redefined Questions and Answers on the basics of fiber optic installation TECHLOGIX NETWORX Questions & Answers Questions and Answers Q: What are the two main types of fiber? A: The two main

More information

Connectix Cabling Systems

Connectix Cabling Systems Connectix Cabling Systems Cabling Standards and CPR Update Connectix CEP Fibre Optic Solutions Jason Holroyd CNID Director of Business Development Types of fibre Agenda Introduction Uses Construction Transmission

More information

Selection of a cable depends on functions such as The material Singlemode or multimode Step or graded index Wave length of the transmitter

Selection of a cable depends on functions such as The material Singlemode or multimode Step or graded index Wave length of the transmitter Fibre Optic Communications The greatest advantage of fibre cable is that it is completely insensitive to electrical and magnetic disturbances. It is therefore ideal for harsh industrial environments. It

More information

Optimax Field Installable Connectors and Installation Tool Kits

Optimax Field Installable Connectors and Installation Tool Kits C O M M E R C I A L N E T W O R K I N G O P T I C A L F I B E R 16.4 FiberExpress Connectors Optimax Field Installable Connectors and Installation Tool Kits AX101982 Optimax LC connector Optimax Field

More information

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable). Nuclear Sensors & Process Instrumentation Fiber Cable Basics Fiber-optic communication is a method of transmitting information from one place to another by sending light through an optical fiber. The light

More information

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber

The Road to Single Mode: Direction for choosing, installing and testing single mode fiber The Road to Single Mode: Direction for choosing, installing and testing single mode fiber Adrian Young Leviton Network Solutions Jim Davis Fluke Networks Adrian Young, Sr. Applications Engineer Leviton

More information

Optical Distribution Box 300 Installation Guide. Version : R0.0

Optical Distribution Box 300 Installation Guide. Version : R0.0 Optical Distribution Box 300 Installation Guide Document No. : OD16-546-L-01 Version : R0.0 Date: 21-Mar-2018 IMPORTANT INSTRUCTIONS When using fiber optic equipment, basic precautions should always be

More information

OpticalProducts. Illuminating Your Network. Testing the World s Networks

OpticalProducts. Illuminating Your Network. Testing the World s Networks OpticalProducts Illuminating Your Network Testing the World s Networks Fibre Optic Testers Ease of use and cost-effectiveness Trend s Family of Optical Products Has Increased The new products include Optical

More information

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available

Cable Jacket - The outermost layer of the fiber cable. Application: Types Single mode Multi mode. Simplex or Duplex available Fiber Optic Products FIBER OPTIC PRODUCTS FIBER OPTIC PATCH CORD CABLE The Construction of a Fiber-Optic Cable Cable Jacket - The outermost layer of the fiber cable. Strengthening fibers - The strengthening

More information

Enterprise Networks. Comms Room and Backbone. in DETAIL

Enterprise Networks. Comms Room and Backbone. in DETAIL Enterprise Networks Comms Room and Backbone in DETAIL 31 Patch Panels 33 CAT 6 CL 16 WAY PATCH PANEL 19 1U Category 6 performance patch panel. Jacks are fitted. Integral cable management and reusable label

More information

HYPERLINE UTP/STP Cable Strippers and Cutters

HYPERLINE UTP/STP Cable Strippers and Cutters 198 HYPERLINE UTP/STP Cable Strippers and Cutters UTP/STP Cable Stripper and Cutter, type 110 HT-318 UTP/STP Cable Stripper and Cutter HT-501 Ordering HT-318 HYPERLINE UTP/STP Cable Stripper and Cutter,

More information

Cable Installation Tips

Cable Installation Tips Cable Installation Tips Campus Network Design & Operations Workshop These materials are licensed under the Creative Commons Attribution-NonCommercial 4.0 International license (http://creativecommons.org/licenses/by-nc/4.0/)

More information

@ Termination and Test Tools. Tools & Test Equipment Product Datasheet.

@ Termination and Test Tools. Tools & Test Equipment Product Datasheet. Tri Hole STRIPPER Fibre Optic Stripper OPT-FOS This hard wearing, easy to handle fibre optic stripping tool includes three stripping guides for: 2mm outer jacket, 900µm Buffer, and 250µm acrylic coating,

More information

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2 Product Catalogue Fiber Optic Assemblies & Adapters Table of Contents 1. General Description... 2 2. Connectors... 3 2.1 SC/UPC... 3 2.2 SC/APC... 3 2.3 FC/UPC... 3 2.4 FC/APC... 3 2.5 ST/UPC... 3 2.6

More information

Cable Installation Tips

Cable Installation Tips Cable Installation Tips Campus Network Design & Operations Workshop These materials are licensed under the Creative Commons Attribution-NonCommercial 4.0 International license (http://creativecommons.org/licenses/by-nc/4.0/)

More information

Introduction to Fibre Optics

Introduction to Fibre Optics Introduction to Fibre Optics White paper White Paper Introduction to Fibre Optics v1.0 EN 1 Introduction In today s networks, it is almost impossible to find a network professional who has never been in

More information

Fiber ICT. Optical Fiber Catalogue

Fiber ICT. Optical Fiber Catalogue Catalogue Index Registers RFP 24-24 Fibers indoor wallmount box..... 02 RFP 48-48 Fibers indoor wallmount box..... 02 RFS 8-8 Fibers wallmount box..... 02 PATCH-24F - Patch Panel F.O. 9 with 24 SC/APC....

More information

SECTION 4 TABLE OF CONTENTS

SECTION 4 TABLE OF CONTENTS Contents Introduction LC, SC and ST Series...4-2 Markets and Applications...4-2 International Standard Documents Compliance...4-2 LC Series Features and Benefits...4-3 LC Standard... 4-4 to 4-5 LC for

More information

SSA Fibre-Optic Extender 160 Fibre Installation Guidelines Version 1.2

SSA Fibre-Optic Extender 160 Fibre Installation Guidelines Version 1.2 SSA Fibre-Optic Extender 160 Version 1.2 0.1 Introduction This document provides information on the specification and installation of optical fibre networks to support SSA optical extender products. SSA

More information

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing.   Rev. 1/31/17 Page 1 of 12 Fiber Optic Testing Testing is used to evaluate the performance of fiber optic components, cable plants and systems. As the components like fiber, connectors, splices, LED or laser sources, detectors and

More information

Belden. Optical Fiber Catalog. Belden FiberExpress Systems, Cable and Connectivity

Belden. Optical Fiber Catalog. Belden FiberExpress Systems, Cable and Connectivity Belden Optical Fiber Catalog Belden FiberExpress Systems, Cable and Connectivity Belden FiberExpress Systems are the definitive choice for all your optical fiber needs. Our focus on quality and detail

More information

The current state of multimode OTDR and Light Source and Power Meter (LSPM) Insertion Loss (IL) testing is as follows:

The current state of multimode OTDR and Light Source and Power Meter (LSPM) Insertion Loss (IL) testing is as follows: APPLICATION NOTE Meeting the Encircled Flux Launch Standard Scope: Guidance on how to test to the Encircled Flux (EF) multimode launch standard using existing optical test equipment and the Optronics Encircled

More information

Follow The Leader In Shielded Technology

Follow The Leader In Shielded Technology 1970s Vampire Tap 1990s Shielded Modular Jack 190s 4 Position Data Connector Follow The Leader In Shielded Technology The new AMP-TWIST Jack is our latest shielded product evolution. It can be terminated

More information

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

Public Works Division Lighting District Fiber Optic Specifications April 2009

Public Works Division Lighting District Fiber Optic Specifications April 2009 Public Works Division Lighting District Fiber Optic Specifications April 2009 7000 Florida Street Punta Gorda, Florida 33950 Tele: 941.575.3600 Fax : 941.637.9265 www.charlottecountyfl.com/publicworks

More information

August " BLANK PATCH PANEL FOR STP KEYSTONE JACKS. 19" PATCH PANEL - 24x STP CAT6A PORTS 19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS

August  BLANK PATCH PANEL FOR STP KEYSTONE JACKS. 19 PATCH PANEL - 24x STP CAT6A PORTS 19 BLANK PATCH PANEL FOR STP KEYSTONE JACKS 19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS WITH EXTRA LONG STRAIN RELIEF BAR The 24-port blank patch panel is designed to use with STP keystone jacks. It can hold up to 24 RJ45 keystone jacks. It features

More information

Connectivity accessories by Nestor Cables

Connectivity accessories by Nestor Cables Connectivity accessories by Nestor Cables NesCon product family includes essential installation and connection accessories for fibre optic networks, from ODFs to joint closures and terminations. www.nestorcables.com

More information

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation

User Manual CXE800. Fibre Optic Receiver. CXX Series. Teleste Corporation Broadband Cable Networks August 30, 2007 1(8) CXX Series User Manual Teleste Corporation CXE800 Fibre Optic Receiver Broadband Cable Networks August 30, 2007 2(8) Introduction The CXE800 is a unidirectional,

More information

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays FIST-MB2-S I N S T A L L A T I O N I N S T R U C T I O N FIST Medium Box for Cable Splicing Only Contents 1 Introduction 1.1 Product description 2 General 2.1 Tools 2.2 Kit contents 3 Installation and

More information

HI-DEX PRODUCT SET DATASHEET

HI-DEX PRODUCT SET DATASHEET APPLICATION HI-DEX is an ultra high-performance, pre-terminated and modular optical fibre cabling system based on MT ferrule connector technology. This product set is designed for installationn in the

More information

SPECIAL SPECIFICATION 6559 Telecommunication Cable

SPECIAL SPECIFICATION 6559 Telecommunication Cable 2004 Specifications CSJ 0015-09-147, etc. SPECIAL SPECIFICATION 6559 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing, training,

More information

Medium Box for Cable Termination

Medium Box for Cable Termination FIST-MB2-T I N S T A L L A T I O N I N S T R U C T I O N Medium Box for Cable Termination Contents 1 Introduction 1.1 Product description. 2 General 2.1 Tools 2.2 Kit contents 3 Installation and pre assembling

More information

Triax TechInfo. Installing and pulling Fibre Optic cables

Triax TechInfo. Installing and pulling Fibre Optic cables Installation methods for both wire cables and Fibre Optical cables are similar. Fibre cable can be pulled with much greater force than copper wire if you pull it correctly. Just remember these rules: 1)

More information

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box

INSTALLATION GUIDE. LANmark-OF Zone Distribution Box LANmark-OF Zone Distribution Box INSTALLATION GUIDE LANmark-OF Zone Distribution Box Document information Release November 2004 Published by Contact address Nexans Cabling Solutions Alsembergsesteenweg

More information

Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52

Assembly code page 46. Cable code page 47. Assembly classes page 48. Polarization maintaining assemblies page 52 cable assemblies Assembly code page 46 Cable code page 47 Assembly classes page 48 Polarization maintaining assemblies page 52 45 Assembly: Ordering code Description cable type 27H01CD0- see cable code

More information

Light Source. Specification & User Manual

Light Source. Specification & User Manual Light Source Specification & User Manual Page 1 of 11 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4

More information

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver 27.3.2012 1(12) CXX Series User Manual Teleste Corporation CXE810 Fibre optic receiver 27.3.2012 2(12) Contents Introduction... 3 Installation... 3 Housing... 3 Powering... 4 Interfaces... 4 Fibre installation...

More information

SPECIAL SPECIFICATION 8540 Telecommunication Cable

SPECIAL SPECIFICATION 8540 Telecommunication Cable 2004 Specifications CSJ 0914-00-307 & CSJ 0914-25-003 SPECIAL SPECIFICATION 8540 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing,

More information

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products MT-RJ Product Expansion Now 0 Variants of the MT-RJ Products In response to several customers, the MT-RJ product line has been expanded with an additional six color/key versions. In addition to the original

More information

Preferred ordering guide for NETCONNECT

Preferred ordering guide for NETCONNECT Preferred ordering guide for NETCONNECT MEA Region Contents Copper solutions Category 6A products 3 Category 6A and Category 7 shielded copper cables 3 Category 6A modular shielded panels 3 Category 6A

More information

Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas

Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas Instalaciones de fibra optica en entornos de centro de datos y campus para suportar 40, 100G y mas Jim Davis Regional Marketing Engineer Fluke Networks Agenda Inspection and Cleaning Loss Budgets TIA (Cabling)

More information

3M Fiber Optic Wall Mount Enclosure 8430 Series

3M Fiber Optic Wall Mount Enclosure 8430 Series 3M Fiber Optic Wall Mount Enclosure 8430 Series Installation Instructions January 2014 3 78-0013-9429-1-A Table of Contents 1.0 Description...3 2.0 Parts...4 3.0 Assembly...4 4.0 Mounting the Enclosure...6

More information

Panduit Recommended Best Case Practice Split Fibre

Panduit Recommended Best Case Practice Split Fibre Panduit Recommended Best Case Practice Split Fibre Panduit Corp. 2009 BEST PRACTICES PN526 Table of Contents 1.0 Enclosure Prep... 2 2.0 Fibre Cable Prep and Installation... 2 3.0 Pigtail Installation...

More information

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

SPECIAL SPECIFICATION 6191 Fiber Optic Cable 2004 Specifications CSJ 0014-02-014, etc SPECIAL SPECIFICATION 6191 Fiber Optic Cable 1. Description. Furnish, install, splice, field terminate, and test the fiber optic cables. 2. Materials. A. General

More information

Fibre Optic Cable & Connector Guide

Fibre Optic Cable & Connector Guide Fibre Optic Cable & Connector Guide White paper White Paper Fibre Optic Cable & Connector Guide v1.0 EN 1 Introduction Organising through cables and connectivity options can be an exasperating exercise.

More information

Crimp & Cleave Termination Instructions for SEL ST Connectors

Crimp & Cleave Termination Instructions for SEL ST Connectors Your Optical Fiber Solutions Partner Crimp & Cleave Termination Instructions for SEL ST Connectors For Use With: ST Termination Kit (SEL, Part Number BT05402-01) 200 µm HCS Fiber-Optic Cable ST Crimp &

More information

Lensed Fibers & Tapered Ends Description:

Lensed Fibers & Tapered Ends Description: Lensed Fibers & Tapered Ends Description: LaseOptics Corporation ( LaseOptics ) has been producing next generation optical lensed fibers. LaseOptics Lensed Optical Fibers technology is proprietary integrated

More information

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting) 2004 Specifications CSJ 0086-14-046 SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting) 1. Description. Furnish, install, splice, field terminate, and test the fiber optic cables. 2. Materials.

More information

Data Sheet HFBR-4531Z/4532Z/4533Z/4535Z. Crimpless Connectors for Plastic Optical Fiber and Versatile Link. Features. Description.

Data Sheet HFBR-4531Z/4532Z/4533Z/4535Z. Crimpless Connectors for Plastic Optical Fiber and Versatile Link. Features. Description. HFBR-4531Z/4532Z/4533Z/4535Z Crimpless Connectors for Plastic Optical Fiber and Versatile Link Data Sheet Description The HFBR-453xZ series connectors are an enhanced version of the HFBR-4501Z and HFBR-4503Z

More information

Tech Breakfast: Fibre Optic Cabling

Tech Breakfast: Fibre Optic Cabling Tech Breakfast: Fibre Optic Cabling An introduction phil.crawley@jigsaw24.com @IsItBroke on Twitter http://www.root6.com/author/phil Fibre optic cabling Applications within Film & TV Single mode vs. Multi

More information

QUEST C6 SOLUTIONS CAT 6 CONNECTIVITY PRODUCTS LAN CONNECTIVITY

QUEST C6 SOLUTIONS CAT 6 CONNECTIVITY PRODUCTS LAN CONNECTIVITY CAT 6 CONNECTIVITY PRODUCTS QUEST C6 SOLUTIONS C6 12-PORT MINI VERTICAL Fig. 3 Fig. 4 C6 16-PORT C6 24-PORT C6 48-PORT CAT 6 PATCH PANELS Quest C6 Patch Panels offer the installers quality and cost effective

More information

onlinecomponents.com

onlinecomponents.com CAT 6 CONNECTIVITY PRODUCTS QUEST C6 SOLUTIONS LAN CONNECTIVITY Fig. 5 Black Fig. 9 Yellow C6 12-PORT MINI VERTICAL Fig. 3 Fig. 4 Fig. 6 Blue 0 Green 3 CAT6 Single Surface Box Fig. 7 Red 1 Ivory C6 16-PORT

More information

LIIN-25 FO Pigtail FC (0.9mm)

LIIN-25 FO Pigtail FC (0.9mm) LIIN25 FO Pigtail FC (0.9mm) Features Single and Multi Mode ISO900, RoHS Compliant Test Certificate for each item Batch number tracking Standards of reference and applications ITU.T G652.D, ISO/IEC 80,

More information

MOST - Roadmap Physical Layer & Connectivity from 150Mbps to 5Gbps

MOST - Roadmap Physical Layer & Connectivity from 150Mbps to 5Gbps MOST - Roadmap Physical Layer & Connectivity from 150Mbps to 5Gbps 13th MOST(R) Interconnectivity Conference Asia on November 15, 2012 in Seoul, South Korea Andreas Engel Manager Advanced Infotainment

More information

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM Content 1. General 5 2. The products of NC-1000 system 6 3. Mounting of the frame 8 4. Earthing of the frame 8 NC-1000 FIBRE OPTIC

More information

OPTICAL FIBERCONNECT. Version 3.

OPTICAL FIBERCONNECT. Version 3. OPTICAL FIBERCONNECT Version 3. OPTICAL Fiberconnect intro In today s CATV networks the requirements for a wide choice of products for network applications are growing rapidly. In this brochure a comprehensive

More information

OPTICAL FIBRE CABLE NETWORK 2004/1

OPTICAL FIBRE CABLE NETWORK 2004/1 OPTICAL FIBRE CABLE NETWORK 2004/1 HELKAMA OPTICAL FIBRE CABLES Cabled optical fibre characteristics OS1 singlemode fibre SM ITU-T G.652 Mode field diameter 1310nm 9.3+/-0.5µm Mode field eccentricity 1.0

More information

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2 3 Crimplok Connectors Quick, easy installation and superior performance To successfully design, install or operate today s fiber optic networks, you need components that offer speed and reliability from

More information

FiberLink 3350 Series

FiberLink 3350 Series MANUAL FiberLink 3350 Series 3G/HD/SD-SDI Transmission over one single mode or multimode fiber Installation and Operations Manual WWW.ARTEL.COM Contents Contents Welcome....3 Features....3 Package Contents....3

More information

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual 100Base-FX Multi-mode to 100Base-FX Single Mode Converter NXF-708 Series User s Manual COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

To select a fibre optic cable, you have to make choices of the fibre selection and the cable construction selection.

To select a fibre optic cable, you have to make choices of the fibre selection and the cable construction selection. Fibre Optic Cables & Connectors Guide Introduction Organising through cables and connectivity options can be an exasperating exercise. It's tough enough working through the categories and levels of copper

More information

COPYRIGHT 2011 AXON DIGITAL DESIGN B.V. ALL RIGHTS RESERVED

COPYRIGHT 2011 AXON DIGITAL DESIGN B.V. ALL RIGHTS RESERVED Fiber connectivity GEP100 - HEP100 Fiber optic connections: an alternative to coaxial 3Gb/s, HD, SD embedded domain Dolby E tocables PCM decoder with audio shuffler A A product application note Quad speed

More information

Fiber Meter. Specification & User Manual

Fiber Meter. Specification & User Manual Specification & User Manual 2009 Copyright 2009, reserves the right to modify specifications without prior notice Page 1 of 8 Table of Contents 1. Description and Features.......3 2. Specification......4

More information

40G SWDM4 MSA Technical Specifications Optical Specifications

40G SWDM4 MSA Technical Specifications Optical Specifications 40G SWDM4 MSA Technical Specifications Specifications Participants Editor David Lewis, LUMENTUM The following companies were members of the SWDM MSA at the release of this specification: Company Commscope

More information

Keyed LC Connector Solution A LANscape Solutions Product

Keyed LC Connector Solution A LANscape Solutions Product Applications Department of Defense installations Secure government facilities Research labs Organizations with a desire to segregate networks due to privacy or security concerns Keyed LC Connector Solution

More information

FiberLink 3500 Series Transceivers

FiberLink 3500 Series Transceivers MANUAL FiberLink 3500 Series Transceivers 2 or 4 Channel 3G/HD/SD-SDI Transmission over one or two single mode or multimode fibers Installation and Operations Manual WWW.ARTEL.COM Contents Contents Welcome...

More information

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017 Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM-2017-2 Date: 05/26/2017 Additional specification information for data communication to cameras and between Library

More information

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1

Click & Go. LWL-NE4-Katalog. Click & Go Modular Solutions. Subject to technical changes! 1 Modular Solutions Subject to technical changes! 1 Since 1986, braun telecom has stood for continuity and competence in broadband communication and has become one of the leading suppliers of products and

More information

LANmark-OF ENSPACE Patch Panel

LANmark-OF ENSPACE Patch Panel LANmark-OF ENSPACE Patch Panel PRODUCT INSTALLATION GUIDE September 2016 v0.11 LANmark-OF ENSPACE Patch Panel PRODUCT INSTALLATION GUIDE Part Number Description Product References NSPACE.PP1U NSPACE.PP2U

More information

Pluggable Transceivers Installation Guide

Pluggable Transceivers Installation Guide Pluggable Transceivers Installation Guide 121140-04 Published November 2017 Copyright 2017 Extreme Networks, Inc. All rights reserved. Legal Notice Extreme Networks, Inc. reserves the right to make changes

More information

SC Connector. Fiber Optic Connectors. MDR Electronics

SC Connector. Fiber Optic Connectors. MDR Electronics SC Connector Fiber Optic Connectors MDR Electronics www.mdrelectronics.com Table of contents 1. Introduction 3 2. Image and line drawing 4 3. Types of connector 5 4. Specifications 6 5. Ask for assistance

More information

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM PTY. LTD A.B.N. 83 003 020 504 OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM Document

More information

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published

How to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published White Paper How to Specify MTP Pre-terminated Optical Cabling Published January 2009 The benefits of pre-terminated cabling The two principal advantages of pre- terminated cabling are reduced time on site

More information

Industry solutions: Broadcast

Industry solutions: Broadcast Industry solutions: Broadcast Bc 2 Industry solutions: Broadcast Optical Cable Corporation s broad range of Fiber Optic Broadcast Cables are specifically designed for real-time transmission of high definition

More information

FiberExpress Connectors Optimax Field Installable Connectors and Installation Tool Kits

FiberExpress Connectors Optimax Field Installable Connectors and Installation Tool Kits C O M M E R C I A L N E T W O R K I N G O P T I C A L F I B E R 16.4 FiberExpress Connectors Optimax Field Installable Connectors and Installation Tool Kits AX101982 Optimax LC Connector AX100029 with

More information

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions Robert Burén Product Manager 10G Solutions Nexans Cabling Solutions 1 10 Gigabit Ethernet.Performance 30 GByte can be transmitted within 24 seconds Example: MRI-scan size is 30GB as average A memory device

More information

3M Distribution Box (DDB)

3M Distribution Box (DDB) 3M Distribution Box (DDB) Merged Copper and Fiber Pole/Post Mount Enclosure Installation Instructions November 2015 78-0015-2736-1-A 2 November 2015 78-0015-2736-1-A Contents 1.0 General 2.0 Enclosure

More information

Datasheet: SimpliFiber Pro

Datasheet: SimpliFiber Pro Datasheet: SimpliFiber Pro Datasheet: SimpliFiber Pro SimpliFiber Pro makes testing simple Fluke Networks' SimpliFiber Pro Optical Power Meter incorporates new and innovative features to give technicians

More information

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48 NS-200AF Series Industrial 0/00 Base-TX to 00 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T NS-200AFT-T 00Base-FX e F -30 ~ +75 +2 ~ +8 LAN x x Fiber Optic Features C C Temperature Automatic

More information

Structured Cabling. Product Line Brochure

Structured Cabling. Product Line Brochure Structured Cabling Product Line Brochure High Performance and Reliable Solution Infinique structured cabling products are manufactured to international standards and are certified for performance and

More information

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications Model Title CC-Link IE Controller Network Compatible CC-Link IE Controller Network Recommended Network Wiring Parts Specifications Management number: BAP-C0401-028-A CC-Link Partner Association (1/31)

More information

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011 SECTION 271323 - COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING PART 1 - GENERAL 1.1 DESCRIPTION A. This section provides the specifications for the work related to the optical fiber system in the project.

More information

HighBand 25. TrueNet Category 6 Solutions

HighBand 25. TrueNet Category 6 Solutions HighBand 25 TrueNet Category 6 Solutions The highest performing cross-connect system in the world. A unique high-density solution with superior cable management. ADC KRONE s HighBand 25 cross connect solution

More information

Fiber Optic Meter Fiber Optic Source

Fiber Optic Meter Fiber Optic Source FOM/FOS Fiber Optic Meter Fiber Optic Source Warning To avoid injury: do not service the FOM or FOS unless you are qualified to do so. The service information provided in this document is for the use of

More information

GATOR PATCH. The ultimate fiber distribution terminal

GATOR PATCH. The ultimate fiber distribution terminal The ultimate fiber distribution terminal PRODUCT OVERVIEW Rugged, Fast, Reliable! Trust the original Gator Patch for all your fiber distribution needs The Gator Patch is a unique, rugged, factory terminated

More information

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page

More information

Scope: Using Wave Division Multiplexing (WDM) for the Protection Data Interface (PDI) of the 7SD5 / 7SD61.

Scope: Using Wave Division Multiplexing (WDM) for the Protection Data Interface (PDI) of the 7SD5 / 7SD61. Page 1 of 10 Using Technology for the PDI of the and 7SA522/7SA6 Scope: Using Wave Division Multiplexing () for the Protection Data Interface (PDI) of the 7SD5 /. Two important issues related to differential

More information

3M No Polish Jacketed SC/APC Connector

3M No Polish Jacketed SC/APC Connector Communication Markets Division 3M No Polish Jacketed SC/APC Connector For use with 1.6 to 3.0 mm Jacketed Cable 3M No Polish SC/APC Connector enables fast, on-site termination of 1.6 mm to 3.0 mm jacketed

More information

PREMIUM 5e F/UTP PRODUCTS

PREMIUM 5e F/UTP PRODUCTS Siemon s end-to-end cabling system is guaranteed to provide transmission performance margins in excess of industry standards for category 5e parameters, while featuring excellent EMI resistance. has been

More information

Best Friends General Trading FZE

Best Friends General Trading FZE Welcome to Best Friends General Trading FZE Tel. +97 1 50-5426 202, Fax. +971 6 7407428, info@bestfgt.com, besttrd@eim.ae Infrastructure Product Guide Best fgt is UAE based company, operational for last

More information

10G SFP+ Modules. 10G SFP+ Module Series

10G SFP+ Modules. 10G SFP+ Module Series Feature Highlights Enhanced Small Form-Pluggable (SFP+) form factor Hot pluggable Support 10G Ethernet Feature Digital Diagnostics Monitoring (DDM) 1 RoHS Compliant Compliant with MSA (Multiple Source

More information

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION

SECTION TESTING, IDENTIFICATION AND ADMINISTRATION PART 1 - GENERAL 1.1 SUMMARY SCOPE SECTION 25170 TESTING, IDENTIFICATION AND ADMINISTRATION 1. This section includes the minimum requirements for the testing, certification administration and identification

More information

40G SWDM4 MSA Technical Specifications Optical Specifications

40G SWDM4 MSA Technical Specifications Optical Specifications 40G SWDM4 MSA Technical Specifications Specifications Participants Editor David Lewis, LUMENTUM The following companies were members of the SWDM MSA at the release of this specification: Company Commscope

More information

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide Limited Warranty One Year Limited Warranty All Noyes products are warranted against defective material and

More information

3M 8900 Single-mode SC Crimplok Connector

3M 8900 Single-mode SC Crimplok Connector 3M 8900 Single-mode SC Crimplok Connector Technical Report June 1999 80-6110-1441-8 1 1.0 Product Description & Requirements The 3M SC Single-mode Crimplok Connector is designed to provide the customer

More information

Datasheet: MultiFiber Pro Update

Datasheet: MultiFiber Pro Update Datasheet: MultiFiber Pro Update Datasheet: MultiFiber Pro Update First MPO tester to support both Singlemode and Multimode MPO fiber testing Data centers are growing, fueled by the proliferation of media,

More information

Small Form-Factor Pluggable (SFP) Module Installation Guide

Small Form-Factor Pluggable (SFP) Module Installation Guide Silver Peak Systems Small Form-Factor Pluggable (SFP) Module Installation Guide April 2018 201294-001 Rev A Contents Introduction... 2 Laser Compliance... 2 Federal Communications Commission Notice...

More information

OTS-300 Express Series Power Meters/Sources and Testers

OTS-300 Express Series Power Meters/Sources and Testers OTS-300 Express Series includes intelligent, versatile optical meters, sources, and testers that simultaneously test and store dual wavelength attenuation measurements. At the press of a button, dual wavelength

More information

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions

MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures. 1. General. 2. Precautions MiniXtend Cable with Binderless* FastAccess Technology Jacket and Buffer Tube Removal Procedures 004-273-AEN, Issue 2 Table of Contents 1. General.... 1 2. Precautions.... 1 2.1 Cable Handling Precautions...

More information

OPTICAL POWER METER WITH SMART DETECTOR HEAD

OPTICAL POWER METER WITH SMART DETECTOR HEAD OPTICAL POWER METER WITH SMART DETECTOR HEAD Features Fast response (over 1000 readouts/s) Wavelengths: 440 to 900 nm for visible (VIS) and 800 to 1700 nm for infrared (IR) NIST traceable Built-in attenuator

More information