1 Braintree Arts Theatre Notley Road Braintree Essex CM7 1WY t: e: Technical Specification Theatre and Technical Manager: Phil Pattie t: PLEASE CONTACT THE TECHNICAL MANANGER TO DISUSS ANY TECHNICAL REQUIREMENTS, OR USAGE OF EQUIPMENT. (Please give as much notice as possible). STAGE (FLAT): Stage Dimensions: (including wing space): Width: 11400mm Depth: 5630mm Height of Stage (from auditorium floor): 558mm Proscenium Arch: Width: 9800mm Height: 3670mm Usual Performance Space: Width: 9800mm Depth: 5630mm Max Height on Stage (From stage floor): Height: 4020mm Get in/out Dock Door: Width: 1480mm Height (from stage level): 2130mm Height (from outside ground level to bottom of door): 672mm Dock Dimensions: Width: 6866mm Depth: 2400mm Maximum Height: 3340mm
2 Dock Stage Entrance: Width: 6866mm Height: 3340mm Off-stage Load in Door: Width:1580mm Height: 2100mm Height (from floor to stage level): 558mm Dressing Rooms There are two main dressing rooms. Each of these dressing rooms has a paging system installed, which carries the show relay and backstage paging system. We can arrange extra dressing rooms but this must be prearranged with a member of our staff. Theatre The theatre seats 300 people (raked seating), or people in a cabaret environment with tables and chairs. The seats can be packed away to create a flat floor environment with the aid of an electrical seating system. The theatre has an infrared assisted listening system for the hard of hearing. Control: 1x Zero 88 Leap Frog (96 channels) Circuits: 3x Zero 88 Chilli Dimmers (24 channels each) 72x 2kw circuits Stage Lighting Stage (24 channels): LX Bar 1 8x 15a circuits (I.W.B), 2x 16a non-dims, 1x DMX Female LX Bar 2 8x 15a circuits (I.W.B), 2x 16a non-dims, 1x DMX Female LX Bar 3 8x 15a circuits (I.W.B), 2x 16a non-dims, 1x DMX Female DIPS: 4x 15a circuits DSL (34, 35, 36, 37) 4x 15a circuits USL 4x 15a circuits DSR (41, 42, 43, 44) 4x 15a circuits USR Front of House: FOH 1 8x 15a circuits (I.W.B) 2x 16a non-dims, 1 DMX Female FOH 2 8x 15a circuits (I.W.B) 2x 16a non-dims, 1x CAT V, 1x Composite video FOH SIDE 1 4x 15a circuits (I.W.B) 1x 16a non-dims, 1 DMX Female (House right) FOH SIDE 2 4x 15a circuits (I.W.B) 1x 16a non-dims, 1 DMX Female (House right) FOH SIDE 3 8x 15a circuits (I.W.B) 2x 16a non-dims, 1x DMX Female (House left) Luminaries: Fresnels
3 12x CCT Minuette x Strand Cantata PC 1kW Profiles 3x Source 4 JNR x Source x Source 4 Zoom x Source 4 Zoom Parcans 14x PAR64 Long Nose (Usually CP62) 4x PAR64 Short Nose Floorcan (Usually CP62) 8x Source 4 PAR Floods 4x Selecon 500w HUI Flood Houselights 4x Selecon 500w HUI Flood Intelligent Fixtures 6x Martin Mac 250+ (only 4x have flying hardware) Effects: 1x Martin Jem Magnum 2000 Fogger 1x HQ Power Haze Machine Other equipment is available but must be hired in, and may incur an additional charge. Front of House: 2 x Mackie Thump 15a Powered Full Range 2 x Mackie Thump 18s Powered Subwoofers Monitoring: 2x Turbosound TXD 12M Monitors 2x Turbosound TXD 121 Mid/Highs 2x QSC PLX 1802 Amplifier Sound Mixing Desk: Soundcraft MFXi20 20 channel with built in 24-bit Lexicon Effects Allen & Heath GL channel
4 Ancillaries: 1x Behringer Ultragraph Pro FBQ3120 (2 channels) 1x Behringer Virtualizer Pro 1x Tascam CD-200 CD Player 1x Samson Powerbite Pro 10 Power Distribution Unit Microphones: 6x Shure SM58 4x Shure SM57 4x Shure PG81 1x Shure PGDMK6 (6 Piece drum mic kit) 4x Sennheiser EW100 G2 Radio Mic 1x Sennheiser EW100 Antenna Distribution Unit 4x Behringer 2-channel DI20 DI-Box Microphone Stands: 8x K&M Tall Boom Microphone Stands 2x K&M Short Boom Microphone Stands 1x Straight Heavy Based Microphone Stand Other equipment is available but must be hired in, and may incur an additional charge. Projector: 1x Sanyo XP100 Pro Xtrax Multiverse Audio Visual Screen: 1x Harkness Hall Major Pro 4m x 4m (Attached to front of proscenium) 1x 3m x 2m Freestanding (or flown) screen can be rigged at back of stage Playback: 1x Denon DN-v110 Pro DVD Player 1x Windows 7 Laptop with Microsoft Office Ancillaries: 2x Atem VGA CAT V 1x Kramer Video - SXGA/HD scaler Facilities Panels DSR: 7x XLR F (to control room) 2x Speakon Outputs (1x FOH L; 1x SR Monitor) 2x CAT V (1x to control room; 1x to FOH 2) DSL: 7x XLR F (to control room) 2x Speakon Outputs (1x FOH R; 1x SL Monitor)
5 1x DMX Output 1x CAT V (to control room) Stage Management Communications: 1x Tecpro Master Station (located in control box) 3x Tecpro Single Ring Beltpacks 3x Tecpro Single Muff Headsets Flying: All LX bars are fixed and there are no flying facilities available. Tabs: 2x FOH Tabs - 5.5m x 3.8m 6x Legs 1.5m - x 4.2m 1x Black Back Cloth - 6.3m x 4.3m Staging: 4x Black topped - 2m x 1m 4x Wood topped - 2m x 1m Other equipment is available but must be hired in, and may incur an additional charge. Onstage Power: 4x Twin 13a Socket SR 5x Twin 13a Socket SL 1x Twin 13a Socket USC 1x 63a 3 Phase Socket SR 1x 32a 1 Phase Socket SR
6
7
Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie
Braintree Arts Theatre Notley Road Braintree Essex CM7 1WY t: 01376 556354 e: enquiries@braintreeartstheatre.com Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie phil.pattie@braintreeartstheatre.com
More informationINFORMATION FOR VISITING COMPANIES
INFORMATION FOR VISITING COMPANIES 2 Middlesbrough Theatre The Avenue Linthorpe Middlesbrough TS5 6SA ADMINISTERED BY MIDDLESBROUGH COUNCIL CULTURAL SERVICES Touring Drama, Dance, Music and Opera, Amateur
More informationDEREHAM MEMORIAL HALL
DEREHAM MEMORIAL HALL is a multi purpose venue incorporating a 294 seat proscenium arch theatre. A standard stage, lighting and sound rig as set out below will be provided, unless otherwise agreed. Any
More informationTechnical Specification
Contact us technical@lutonculture.com General Facilities Seating Capacity 238 on raked seating with centre aisle Stage Dimensions 6.4m deep x 8m wide Height of grid 4.2m Height of stage from the auditorium
More informationTechnical Specification Pavilion Dance
Technical Specification Pavilion Dance Contact Information Position Name Email Phone Number Technical Manager Technician Neil Kingston Louise Buckton neil@pdsw.org.uk louiseb@pdsw.org.uk 01202 203630 01202
More informationTechnical Specification for the Alley Theatre, Strabane
Technical Specification for the Alley Theatre, Strabane All technical requests should be made to Andrew Orr, Technical Officer. Contact Details Andrew Orr The Alley Theatre, Railway St, Strabane, BT82
More informationTechnical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3
Sound Console: Soundcraft Si Performer 3 32 mono mic inputs 80 channels to mix Freely assignable faders and patching Colour backlit LCD screens per fader 20 sub-group / aux busses 8 Matrix busses LCR panning
More informationRhodes Arts Complex Bishops Stortford. Technical Specifications
Rhodes Arts Complex Bishops Stortford Technical Specifications Auditorium Seats up to 299 on retractable raked seating including balcony and 4 optional flat rows at floor level. At capacity there is a
More informationThe Tower Theatre Contact - Peter Heselden Theatre Manager Tel
The Tower Theatre Contact - Peter Heselden Theatre Manager Tel- 07711710925 Email- pjwh15@msn.com The Tower Theatre has a seated capacity of 285 in the auditorium with 6 wheel chair positions. The box
More informationHIRE AND TECHNICAL INFORMATION
HIRE AND TECHNICAL INFORMATION 2 Table of Contents Stage Information... 3 Accommodation... 4 Lighting Equipment... 5 Sound Equipment... 7 In-House Cloths... 8 Stage Plan... 9 Contact Information.. 10 Parking
More informationMatt Dann Cultural Centre
Matt Dann Cultural Centre Matt Dann Theatre Technical Specifications 13/07/09 Technical Manager: Brad Holder Phone number: 08 9158 9369 Mobile Number: 0447 632 936 Fax number: 08 9172 2472 Email address:
More informationSR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.
TECHNICAL INFORMATION MAIN HOUSE STAGE DIMENSIONS The main stage is a flat floor sprung hardboard stage with a proscenium opening of 10.5m x 9.1m depth. The proscenium height is variable by the house border
More informationCHELSEA THEATRE. Technical Specifications
CHELSEA THEATRE Technical Specifications DIMENSIONS Stage depth From setting line to back wall From front of seats to back wall Width of stage Grid height 6600mm 7200mm 9600mm 3800mm Auditorium Capacity
More informationTechnical specifications Main theatre. Sound
Sound Console: Soundcraft Si Performer 3 32 mono mic inputs 4 stereo line inputs 4 stereo Lexicon effects engines Stagebox: Soundcraft Mini Stagebox 32R 32 analogue inputs 8 analogue outputs 4 AES Out
More informationTheatre Technical Specification
Theatre Technical Specification The information contained in this specification details the standard technical provision offered by the Brewhouse for visiting companies, artists and hirers. It details
More informationDugdale Centre Technical Specification
Dugdale Centre Technical For further information please contact Tech Team Millfield.technical@enfield.gov.uk Technical Office: 020 8887 7315 Box Office: 020 8807 6680 Venue Hire: 020 8887 7333 www.dugdalecentre.co.uk
More informationStage. Get In & Parking
Stage Capacity Stage Rigging Masking Auditorium 230 seats or 216 seats if front row removed. Wheelchair positions front row and upper auditorium right. Raked seating upper & lower house. 9.45m wide x 6.9m
More informationTECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE
TECHNICAL SPECIFICATION FOR WYLLYOTTS THEATRE Wyllyotts Theatre, Wyllyotts Place, Darkes Lane, Potters Bar, Hertfordshire. EN6 2HN 1 Contents Pg. 3: Pg. 4: Pg. 5: Pg. 6: Pg. 7: Pg. 8: Wyllyotts Theatre
More informationTechnical Specification. Updated: April 2016
Technical Specification Updated: April 2016 Venue Address: The Core at Corby Cube Parkland Gateway George Street Corby Northants NN17 1QG Contact: Andy Swinney Technical Manager Tel: 01536 470475 Email:
More informationTechnical Specifications Updated 01/10/2017. Stage
Stage Capacity Setting Line Stage Please see your contract for capacity. Setting line(s) is 1.35m from the step of row A of the seating bank or 1.35 from the onstage edge of seats. All fire paths should
More informationStage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m
Main House Technical Specification Get In Access for loading and unloading is via St Stephen s goods yard into the Hull Truck loading bay. Flat access at Stage Level for HGV s, backing directly onto main
More informationSummary. Access and Parking
1 Summary Cornerstone arts centre consists of the main house which is 217 seat end on format with raked seating. An extra row (AA) of flat floor seating can be added giving a capacity of 234. The stage
More informationArlington Arts Tech Spec 2018
Arlington Arts Tech Spec 2018 Summary The Arts centre consists of the main house which is 250 seats end on format with raked seating. The first five rows are retractable bleacher style seating. There are
More informationCornerstone Technical Specifications 2018 / V1
Cornerstone Technical Specifications 2018 / V1 Cornerstone is a purpose-built, professional arts, culture and entertainment venue in the heart of Didcot, brought to you by South Oxfordshire District Council.
More informationNew Theatre Royal Lincoln Technical Information
1 New Theatre Royal Lincoln Technical Information Please note that some items on our tech spec are subject to a recharge. Please contact Steve Chambers the Technical Manager on 07985 275522 or email technical@newtheatreroyallincoln.com
More informationMain House Technical Specification
Main House Technical Specification Technical Stage Manager: Assistant Technical Stage Manager: Nearest train station: Christchurch Population: 47,300 Distance to London: 105 miles Shaun Luckly Tel: 01202
More informationO Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway
O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway INCOMPLETE AS OF 09-04-2017 DRAFT PURPOSES ONLY 1 of 13 Contents Contents Pg 2 Address Pg 3 Staff Pg 3 Telephone
More informationThe Lights Technical Guide June 2017
The Lights Technical Guide June 2017 The Lights, West Street, Andover, Hampshire SP10 1AH Tel: 01264 368368 www.thelights.org.uk music theatre comedy dance education conferencing The Lights Andover is
More informationLighthouse Theatre Technical Specification
Lighthouse Theatre Technical Specification Auditorium Ground Floor 15.3m x 17.5m Balcony 4.5m x 17.5m Capacity 548 Seating Disabled Seating General Fixed tiered seating; 405 ground floor, 119 balcony,
More informationStandard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)
AUDITORIUM PERFORMANCE AREA Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black) Standard (with THRUST seating) 6.1m Wide
More informationStage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking
Stage Capacity Auditorium 230 seats (216 seats when front row is removed). Wheelchair positions front row and upper auditorium right. Raked seating split onto lower & upper house. Stage Width - 9.1m Depth
More informationDr JOHN GALLAGHER CONCERT CHAMBER
1 TECHNICAL SPECIFICATIONS Dr JOHN GALLAGHER CONCERT CHAMBER STAGE DIMENSIONS 12.5m wide at the downstage edge tapering to 10.7m wide at the far upstage wall. 8m in depth Elevated 0.9m from main auditorium
More informationISLAND HALL TECHNICAL INFORMATION
ISLAND HALL TECHNICAL INFORMATION Lagan Valley Island, The Island, Lisburn, BT27 4RL Telephone: 028 9250 9250 (Reception) If you have any queries regarding this technical information please contact either:
More informationTechnical Pack. Attenborough Arts Centre
Technical Pack Attenborough Arts Centre 1 Introduction This pack is designed to offer the user a detailed overview of the technical capabilities that the Attenborough Arts centre is able to provide. This
More informationMain House Technical Specifications
Main House Technical Specifications Technicians Senior Technician - Stephen Payne Technician - Drew White Technician - Joanne Marshall Arena Theatre Wulfruna Street Wolverhampton WV1 1SE Tel: 01902 321
More information* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.
Technical Information Centerville Performing Arts Center Centerville High School 500 E. Franklin Street, Centerville, OH 45459 Theatre Manager: Mike Cordonnier Office: 937-439-3535, Fax: 937-439-3574 E-Mail:
More informationUNIVERSITY CONCERT HALL. Technical Specification
UNIVERSITY CONCERT HALL Technical Specification Auditorium Total Seating 1,039 Seating breakdown Ground Floor 795 Balconies 191 Choir Stall 53 Wheelchair lift to four disabled positions Stage Performing
More informationTechnical Specifications
Technical Specifications Technical Manager: Kevin Wilkins kbw@canford.com 01202 847543 Theatre Administrator layardtheatre@canford.com 01202 847529 All equipment is subject to availability. Please check
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS September 2017 TECHNICAL CONTACTS Technical Manager Clive Stevenson 01865 319451 stevensonc@thenorthwall.com Stage Manager Rebecca Welburn 01865 319451 welburnr@thenorthwall.com
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS MAIN HOUSE TECHNICAL SPECIFICATION LIGHTING ETC ION lighting desk with 2x 20 fader bank (NB this is an XP ION) 126 ways of dimming supplied by LSC digital dimmer packs. All outlets
More informationHarrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel
Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel 020 8416 8989 email harrowartscentre@harrow.gov.uk web www.harrow.gov.uk www.harrowartscentre.com Elliott Hall: Technical
More informationThe Haymarket Basingstoke Technical Specifications
The Haymarket Basingstoke Technical Specifications The Haymarket Wote Street Basingstoke Hampshire RG21 7NW 01256 819797 Administration 01256 844244 Box office 01256 331733 Fax For further information
More informationTech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)
Tech specs: Main Auditorium 900 (650 seated on ground floor, 250 on balcony) 1050 (800 standing on ground floor, 250 on balcony) Dimensions Pros Arch 20m x 5.6m high Pros Width 20m (Adjustable via tabs)
More informationTheatre Technical Specifications
The Esplanade, Weymouth, Dorset, DT4 8ED 01305 783225 Theatre Technical Specifications Created by David Tozer, Technical Manager. dave@weymouthpavilion.com 1 of 10 Updated November 2015 The Theatre The
More informationTechnical Specification Ardhowen Theatre
Technical Specification Ardhowen Theatre Stage Proscenium Width Depth Forestage Height Stage Floor Flying System Stage Manager Orchestra Pit House Curtains Masking Cyclorama 8.6M (28.2ft) wide by 5.3M
More informationTechnical Specifications
Technical Specifications Updated Curatorial Statement is a Page 2 of 14 Theatre Stage Description: The Theatre is a flat floor space on the First Floor of the former Geelong Law Courts with 128 seat retractable
More informationThere are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.
Technical Specification Adrian Sweeney Technical and Buildings Manager Office: 01483 739063 Stage Door: 01483 739040 Email: asweeney@glive.co.uk Web: GLive.co.uk 1. Auditorium Capacity Fully seated with
More informationTechnical Specification
Technical Specification Contacts Theatre Hire Sonja Gysin 01271 852392 Sonja.gysin@petroc.ac.uk Theatre Technician Richard Smith - 01271 852432 Richard.smith@petroc.ac.uk Petroc, Old Sticklepath Hill,
More informationTechnical Manager Dave Nott Tel: * Mo: Deputy Technical Manager Anton Holmes Tel: *
STAFF Technical Manager Dave Nott Tel: 01438 242612* Mo: 07766 445779 Email: dave.nott@sll.co.uk Deputy Technical Manager Anton Holmes Tel: 01438 242614* Email: anton.holmes@sll.co.uk Senior Technician
More information2017 TECHNICAL SPECIFICATIONS
2017 TECHNICAL SPECIFICATIONS Venue Address: Shirley Burke Theatre 64 Parkers Road, Parkdale Victoria 3195 SBT Theatre Coordinator: Tracey Kean Phone number: 9580-4998 Mobile number: 0400-657-987 tracey.kean@kingston.vic.gov.au
More informationMAIN THEATRE TECHNICAL SPECIFICATION
Alcester Street, Redditch, Worcestershire, B98 8AE MAIN THEATRE TECHNICAL SPECIFICATION Updated 28 th February 2018 Administration 01527 61544 Select department from the options Box Office 01527 65203
More informationMAIN AUDITORIUM TECHNICAL INFORMATION
MAIN AUDITORIUM TECHNICAL INFORMATION Version 4.16 October 2016 Epsom Playhouse Ashley Avenue Epsom Surrey KT18 5AL Technical Office 01372 728887 playhousetech@epsom-ewell.gov.uk .GENERAL INFORMATION.
More informationMAIN HOUSE TECHNICAL SPECIFICATION
MAIN HOUSE TECHNICAL SPECIFICATION LIGHTING frog 2 Lighting Console 600 AMP 72 way LSC digital dimmers supplying Stage and FOH 63 AMP Single Phase 6 way dimmer pack FOH bridge DMX POINTS Control Room,
More informationMAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014
Alcester Street, Redditch, Worcestershire, B98 8AE MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014 Administration 01527 61544 Select department from the options Box Office 01527 65203 For
More informationThe Georgian Theatre Royal Technical Information For Visiting Companies
TECHNICAL EQUIPMENT SCHEDULE 2013 Edition (All equipment is subject to availability) ***ATTENTION VISITING MANAGER/PROMOTER*** Please ensure that the relevant pages of this document (or copies of) are
More informationTechnical Information
Technical Information Gracie Fields Theatre, Oulder Hill Leisure Complex, Hudsons Walk, Rochdale, Lancashire OL11 5EF Administration: Nikki Jackson Theatre Manager T: 07824 374913 E: nikki@graciefieldstheatre.com
More informationDerby Theatre. Technical Information Main Stage. Derby Theatre. 15 Theatre Walk. St. Peters Quarter. Derby DE1 2NF.
Derby Theatre Technical Information Main Stage Derby Theatre 15 Theatre Walk St. Peters Quarter Derby DE1 2NF 01332 593900 L.Barkes@derby.ac.uk technical@derbytheatre.co.uk www.derbytheatre.co.uk Introduction
More informationTechnical Services and Specification
Technical Services and Specification BRAUNTEX PERFORMING ARTS THEATRE ASSOCIATION, INC. 290 West San Antonio New Braunfels, TX 78130 (830) 627-0808 FAX (830) 627-0809 Operations Manager: Ben Nowotny -
More informationSalisbury Arts Centre Technical Specification v Page 1 of 7
Salisbury Arts Centre Technical Specification v2015.1 Page 1 of 7 Box office: 01722 321744 Admin office: 01722 343020 Email: info@salisburyarts.co.uk www.salisburyartscentre.co.uk Direct line: 01722 343021
More informationTheatre Technical Specifications
Theatre Technical Specifications The Lakes Theatre STAGING INFORMATION Seating Capacity: Total 1200 seats Stage Dimensions: Width at widest Part 18m Rear stage width- 13m Stage depth (at centre) 7.4m Height
More informationConcert Hall Technical Specifications
Concert Hall Technical Specifications Revised 11/1/2014 4132 East Pecos Road Gilbert, AZ 85295 Phone: (480) 279-7190 Fax: (480) 279-7590 Website: www.higleyarts.org HCPA Overview The Higley Center for
More informationMERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.
MERMAID ARTS CENTRE Outline Technical Specifications as of 17 th January 2018. At Mermaid we are regularly upgrading our inventory. Please ensure you have a current version of this document. Note: Please
More informationThe Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW
The Haymarket Technical Specifications The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW Head of Production E: ruairi.mcnulty@anvilarts.org.uk T: 01256 819797 Ext: 118 Production and E: amanda.wise@anvilarts.org.uk
More informationDRAÍOCHT Technical Specification: MAIN SPACE
DRAÍOCHT Technical Specification: MAIN SPACE Auditorium: 286 seats. If the sound desk is required to be on the balcony 6 seats will be lost. If a band/orchestra is placed on the floor in front of the stage
More informationBackstage Accommodation (Ground Floor Mezzanine Level 1 Floor above Loading Bay)
General Get-In Loading Bay 300mm above road level via ramp, with sectional up & over door.79m wide x 3.7m high. Internal dims 15m long x 3.m wide x 4.1m high, plus further storage area approx..4m long
More informationCENTRE FOR PERFORMING ARTS
CENTRE FOR PERFORMING ARTS Venue, Facilities & Equipment CPA VENUE AREA SIZE FUNCTION Dressing Room (Female) 6 x 12m Dress and makeup room with attached toilet and shower facilities Dressing Room (Male)
More informationDarlington Hippodrome Technical Specification
Darlington Hippodrome Technical Specification 1. Introduction 2. H&S 3. Contact Us 4. Stage 5. Flying 6. Drapes, Masking 7. Stage Management 8. LX control, dimmers, Stock, Aux power 9. Sound 10. Control
More informationA red velvet front of house curtain closes off the main stage leaving only the apron visible to the audience.
The Stage Area The stage is a ground level trapezoidal shaped space with a proscenium arch and a curved apron forestage. A draped off rear stage provides a crossover. The rear stage can be separated using
More informationETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers
PAVILION THEATRE TECHNICAL INFORMATION LIGHTING Permanent fixed lighting rig on fixed dead hung internally wired bar consisting of a 4 colour wash (Lee filters 106 Primary Red, 119 Dark Blue, 105 Orange
More informationTechnical Information
Technical Information The Berry Theatre Wildern Lane Hedge End Hampshire SO30 4EJ theberrytheatre@eastleigh.gov.uk 01489 783 473 ext 253 (The Berry Theatre Office) 023 8062 7803 (The Point Technical) www.theberrytheatre.co.uk
More informationTechnical Specification & Production Pack
Technical Specification & Production Pack Updated September 2016 The information contained in this pack is subject to change and should be used in consultation with the theatre s Technical and Production
More informationPleasance London Main House Visiting Company Information Pack May 2017
Pleasance London Main House Visiting Company Information Pack May 2017 Contact List Director Anthony Alderson anthony@pleasance.co.uk General Manager Hamish Morrow hamish@pleasance.co.uk Head of Comedy
More informationGORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16
WWW.GORDON-CRAIG.CO.UK BOX OFFICE 01438 363 200 GORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16 STAFF CHIEF TECHNICIAN (SOUND) Dave Nott Email: dave.nott@sll.co.uk Tel: 01438 242612 Mob:
More informationTechnical Specification
Technical Specification Address: The Mill Arts Centre Spiceball Park Road Banbury OX16 5QE Website: www.themillartscentre.co.uk Telephone: Box Office: (01295) 279002 Head of Technical and Production: Dan
More informationDinkelspiel Auditorium - Technical Specifications
Mailing Address Stanford Music Department 541 Lasuen Mall Stanford, CA 94305 Venue Address 471 Lagunita Dr Stanford, CA 94305 Production Coordinator Kevin Sweetser ksweets@stanford.edu House Specifications
More informationHIRERS INFORMATION PACK For further technical information or enquiries please contact:
HIRERS For further technical information or enquiries please contact: Matt Earles / Theatre manager / mearles@berkhamstedschool.org / 07557 161 040 Andrew Ibbott / Theatre technician / aibbott@berkhamstedschool.org
More informationTheatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:
Theatre SPECIFICATIONS UPDATED: 13/08/13 ADDRESS: 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: 08444068666 FAX: 08444068667 TECHNICAL MANAGER: E MAIL: JAKE SUTTON JAKES@LIGHTHOUSEPOOLE.CO.UK GENERAL
More informationTechnical Specifications Nov 2016
Technical Specifications Nov 2016 November 2016 1 Cambridge City Centre is a bicycle friendly city. There is short stay car parking in the area of the city, but all of it is expensive for a day stay. The
More informationConcert Hall Technical Specifications
Concert Hall Technical Specifications Revised 12-14-2017 4132 East Pecos Road Gilbert, AZ 85295 Phone: (480) 279-7190 Fax: (480) 279-7590 Website: www.higleyarts.org HCPA Overview The Higley Center for
More informationPerforming Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)
1 Seating Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI 49544 Phone: (616) 647-0939 Fax: (616) 647-0149 Technical Specifications As of June 2009 Total Seating Capacity 756 + 4 wheelchair spaces
More informationStage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.
Technical Specifications: Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used. Proscenium Opening Height: 16 ft. Width: 36 ft. Drapes in, approx.
More informationInformation for Incoming Companies
Information for Incoming Companies The Stables Theatre Stockwell Lane Wavendon Milton Keynes MK17 8LU General The Stables is an internationally renowned music organisation with a vision to engage the widest
More informationLatrobe Performing Arts Centre
Latrobe Performing Arts Centre Traralgon Town Hall Technical Specifications Updated 24/5/07 Technical Manager: Phone number: 03 5176 3426 Mobile Number: 0428 378 121 Fax number: 03 5176 3426 Email address:
More informationTECHNICAL SPECIFICATION
Wyvern Theatre Theatre Square Swindon SN1 1QN Admin: 01793 535534 Ticket Office: 01793 524481 TECHNICAL SPECIFICATION Access & Parking: The Loading Dock and Stage Door are located at the end of Islington
More informationSource 4 Junior Zoom Profile 575W 14 part of universal rig
Lighting Lanterns Identity Description Type Rating Number Comment H016, H110-H114 Pattern 23 Profile 500W 6 H110-H114 have shutters H030, H031 Minim 26 Profile 500W 2 H046-H051, H079-H080, H085-88, H115-H116
More informationTechnical Information
Technical Information For more information please call Booking Agent and Manager: James Marsh 781-586-6770 General Information www.lynnauditorium.com The Lynn Memorial Auditorium is located in historic
More informationHopgood Theatre NOARLUNGA CENTRE
Hopgood Theatre NOARLUNGA CENTRE TECHNICAL FACILITIES Technical Manager: Paul Smith 0402 574 694 (M) paul.smith@countryarts.org.au Ramsay Place, PO Box 747 Noarlunga Centre, SA 5168 Box Office: (08) 8207
More informationTechnical Specification 2016
Technical Specification 2016 The theatre does not guarantee that ALL equipment listed below is available and working. Please check with at least 4-weeks notice if there is anything critical (for example,
More informationTECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013
TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA 01420 UPDATED March 2013 Cultural Affairs Office: 978-665-3709 Web Site: www.fitchburgstate.edu/cultural
More informationRPAC REDLANDS PERFORMING ARTS CENTRE
RPAC REDLANDS PERFORMING ARTS CENTRE CONCERT HALL Technical Specifications STAGE FACILITIES Soft Proscenium Theatre mode (see stage masking) Concert Platform (open area with acoustic walls on PS, OP and
More informationPLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.
Updated on Monday, 29 January 2018 Get In 1) Via Small Goods lift (Street Level) dimensions 1.10m (W) x 1.10m (L) x 2.10m (H) 2) Via Goods lift dimensions 2.5m (W) x 4.0m (L) x 3.0m (H) and along a corridor
More informationNEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY
NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY VICTORIA THEATER TECHNICAL SPECIFICATIONS Correct as of 11.08.07 Page 1 of 7 LOAD IN The Victoria Theater stage is directly accessible via loading dock
More information20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)
Technical Information Stage: Proscenium arch with apron SL Wall - SR Wall: 14.99m Setting Line - U/S Fly Bar: 7.57m Setting Line (under pros, DS edge when orchestra pit out) Back Wall: 8.17m Proscenium
More informationMONASH University Academy of Performing Arts
MONASH University Academy of Performing Arts ROBERT BLACKWOOD HALL Technical Specifications Matthew King Technical Manger Phone number: (03) 9905 1689 Email address: matthew.king@monash.edu Updated December
More informationFestival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy
Festival City Theatres Trust Festival Theatre Technical Specification Smoking Policy It is the policy of Festival City Theatres Trust that all of our workplaces are smoke-free and all employees and visiting
More informationTechnical Specification (Studio Theatre)
Technical Specification (Studio Theatre) TECHNICAL INFORMATION LOADING BAY The loading bay can be accessed from Kirk Terrace via Prinsep Street. Loading access to the Drama Theatre is through a passageway
More informationPhil L. Thomas Performing Arts Center Shiprock, New Mexico
Phil L. Thomas Performing Arts Center Shiprock, New Mexico Technical Specifications STAGE DIMENSIONS Proscenium 45-4 wide x 24 high Proscenium to up stage wall 29 6 (from back of proscenium opening wall)
More informationTechnical Specification Ver 01/16
Technical Specification Ver 01/16 Overview The Playhouse Theatre does not guarantee that all or any of these facilities or equipment will be available or suitable for the purposes of the visiting company.
More informationTechnical Information
5/3/2006 1 Hamilton Place Theatre / Studio at Hamilton Place / Copps Coliseum / Hamilton Place Convention Centre Ronald V. Joyce Centre for the Performing Arts Technical Information Building with members
More informationTechnical Specifications
Technical Specifications Lighthouse Studio Version 4.1 13/05/16 Technical Services Coordinator: Xavier Dannock Phone number: 03 5559 4988 Mobile Number: 0402 973 030 Email address: xdannock@warrnambool.vic.gov.au
More information