The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW
|
|
- Erik King
- 6 years ago
- Views:
Transcription
1 The Haymarket Technical Specifications The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW Head of Production E: T: Ext: 118 Production and E: Facilities Administrator T: Ext: 164 Programme Assistant E: T: Ext: 108 Please note the equipment listed here may not always be available, please check with the Production Department. Updated November 2017 Page 1
2 MAIN HOUSE STAGE / FLYING Stage plan: See Appendix A Staging: Proscenium Opening Stage Depth Setting line to Back Wall Setting Line to Edge of stage Setting Line to Edge of Forestage/Pit Lift Depth of Forestage/Pit lift Height of stage from Stalls Level Height to Underside of Fly Floor Height to Underside of Grid Width between Fly Floors 8970mm (w) x 5000 mm (h) 8030mm at Centre Line 1450mm 3100mm 1640mm 940mm 6350mm 10230mm 10400mm LX bars distances from the setting line: LX1: 600mm LX2: 2200mm LX3: 3800mm LX4: 5600mm LX5/Flood bar: 6200mm Backdrop: 7200mm Flying: Hemp Sets 29 Winches 5 Advance FOH Winch Truss 1 Bar Width 10000mm SWL: Hemps Kg UDL / 55Kg PL Winches Kg UDL / 60Kg PL House Curtain Kg UDL FOH Truss Kg UDL (UDL = Uniformly Distributed Load / PL = Point Load) Updated November 2017 Page 2
3 GET IN Access to stage is not level and requires either the use of the auditorium pit lift or winch system at the dock door. The Dock door is +4200mm above ground level and all items must be winched in from ground level by a single pickup motor hoist. Max Dimensions for Get Ins: Via Dock +4200mm (h) 2.5M x 5.3M Via Stage Door/Pit Lift 2.4M Diagonal POWER SUPPLIES DSR / Scenery Dock 1x 63A 3 Phase / 1x 63A Single / 1x 32A Single / 2x 16A Single DSL 1x 32A Single Phase Audio Power / Clean Supply A selection of domestic 13 amp sockets are available around the stage and auditorium 24x 15A Non-Dim circuits Stage Manager s desk situated DSR comprising: COMMUNICATIONS Cue Lights control station Infrared stage video monitor Show timer FOH and Backstage Paging A belt pack and headset intercom attached to the desk Intercom comprising: 10 x 1 channel belt packs and headsets 9 x Cue lights Additional communications including: 2 channel IR audio descriptive system Video and audio show relay Video and audio patch running to various points round the building Updated November 2017 Page 3
4 DRESSING ROOM FACILITIES 2 x en-suite dressing rooms suitable for 1 or 2 performers ( D & C ) 2 x Large Chorus dressing rooms suitable for a maximum of 20 performers each 1 x Dressing room suitable for up to 4 people ( B ) 1 x Dressing Room suitable for 4 people / Visiting Company Managers Room ( A ) 1 x Additional Performer Storage Room 1 x Laundry room Each dressing room has a safe for personal possessions There are 5 toilets which are used by staff and performers Dressing Dressing Chorus Chorus Stairs to SL Room D Room C Dressing Room 1 Dressing Room 2 Sound Kitchen Store Toilet Showers & Toilets Toilets Dressing Room B Stairs to SR Stage Door Under Stage Crossover & entrance to orchestra pit Orchestra Pit Pit Store Laundry room LX Store Crew Room Storage Dressing Room A Updated November 2017 Page 4
5 AUDITORIUM MIXER POSITIONS The House mixer position is located at the rear of the Stalls. The Mixer Position can be moved to the control box at the rear of the circle or be operated from the side of stage. Tie lines around the stage and auditorium allow you to patch into the house system from a variety of locations. View from Control Room Position View from Stalls Mixer Position Updated November 2017 Page 5
6 FORMATS The Auditorium Pit Elevator can be used in 3 positions. 1. At stage level to create a stage extension 2. At Auditorium level (usual position) 3. At Orchestral Pit Level Updated November 2017 Page 6
7 ORCHESTRA PIT An orchestra pit is available in some formats. 13A Power is available in the Orchestra pit. 12 Music stands with lights are available for use in the pit and 1 lit conductor s music stand. Please see Appendix A for a section showing pit positions. STAGE EQUIPMENT AND MASKING A selection of hard masking flats is available to create a variety of formats. To supplement this, the following are also available: 1 x Full White Cyclorama 1 x Full Blacks (2 Pieces) permanently rigged 1 x Tab Swipe Track 1 x Curtain Track 1 x Red House Curtain (permanently rigged) 2 x Book flats for onstage quick change areas 2 x Treads for auditorium/stage access 2 x 8 x 4 Lite Deck at 1 Height 1 x Full black Gauze 1 x White Gauze 1 x Set of Thin Black Blinders in 2 parts 1 x Set of Blacks Dip Traps run the depth of the stage at either side and underneath the Iron. These can be seen on the plans in Appendix A Black Harlequin dance floor is available to cover the entire stage on request. Updated November 2017 Page 7
8 LIGHTING Control: ETC Ion Lighting Control Desk; 2x DMX Outputs, 512 Ch; 999 Cue Lists; 200 Active Playbacks / Universal Fader Wing with 2 rows of 20 Faders Dimmers: Lanterns: 205 way ETC Sensor. 20 Non Dim Circuits Availability on lanterns varies due to an ongoing maintenance schedule. Please confirm availability when submitting a lighting plan. The current full lantern stock is listed below: Lanterns Stock: 30 Par Cans 13 Floor Cans (7 black and 6 silver) 45 Selecon Rama 150 Fresnel 1.2k 2 Selecon 2.5k Arena Theatre Fresnel 13 ETC Source 4 with 19/26/36 degree lens tubes and one 50 degree. 12 ETC Source 4 Zoom (permanently rigged on the FOH Bridge) 25 ETC Source 4 Zoom Jnr (25 to 50 degree lens) 16 Coda 1K 1 Source 4 Jnr 6 3 channel Flood Battens 12 Birdies Gobo holders and Irises are available for the majority of lanterns. Please contact the Production Department for advice on availability. Updated November 2017 Page 8
9 SOUND Mix Position: There are two available mix positions for FOH. One is sited at the rear of the stalls underneath the circle balcony. This position is suitable for larger consoles and has a clear view of the stage. Only 13a power is available at this mixing position. No seating requires removing to use this position. N.B Visiting companies please be aware; this mix position can accommodate most consoles. However some larger consoles will not fit due to space restrictions. The second is located inside the control room. There is a sliding glass window which can moved to allow a clear listening position of the P.A. This position is not suitable for large or digital consoles due to restricted space and no multicore run. Only 13a power is available at this mixing position. Tie lines around located around the stage and auditorium allowing you to patch into the house system from a variety of locations. Mixing Desks: Midas M32 Digital The Midas M32 is our permanent FOH console. It can be removed if needed so please advise if you require this. Visiting companies please be aware, this mix position can accommodate most consoles. However some larger consoles will not fit due to space restrictions. 40 Inputs: 32 XLR 6 1/4 Jack Stereo RCA 1 Talkback Mic Input 22 Outputs: 16 Freely assignable XLR 2 Monitor XLR 2 Monitor 1/4 Jack 2 1/4 RCA 4 Band EQ on each input channel 25 Time aligned and Phase Coherent Mix buses 6 mute groups 8 stereo signal processing effect engines including boutique EQ and compressors 7 TFT Display Auto-ranging universal switch mode power supply 32x32 USB audio interface Updated November 2017 Page 9
10 Digital Stage Boxes 2 x Midas DL16 stage boxes. 16 Input 8 output. Allen & Heath MixWizard WZ3 16:2 16 mic / line inputs Mono fader feeds Mono XLR output 6 Auxiliary Sends 4 Band EQ Plus HPF 2 Stereo Returns On-Board Digital FX P.A System P.A system built around a ground stacked EM Acoustics system. This is supplemented with various delays around the auditorium for extra stalls and circle coverage. Stalls Level Stereo PA 2 x EMS 152 Full Range 2 x EMS 81 in fills 2 x i12 ULF subwoofer 2 x EMS 215 subwoofer 1 x EMS 81x Stalls centre fill mounted above proscenium Circle Level Stereo PA 2 x EMS 122 Full Range Extras 2 x EMS 61 can be mounted on rear of lighting bridge for extra circle coverage Processing 1 x XTA DP 448- Main PA and Delays 1 x XTA DP 424- Subwoofers N.B The P.A system has been installed and set up by the manufacturer, and as such the settings of our processors cannot be changed. Updated November 2017 Page 10
11 Amplifiers 3 x Full Fat Audio 6000 Amplifiers EMS 152 full range i-12 subwoofer EMS 215 1x FFA 4004 amplifier EMS 61 EMS 81 1 x FFA 6004 amplifier EMS 122 EMS 81x (prosc fill) EMS 81 (stalls in-fill) 2 x FFA 6004 amplifier 8 channels of amplification for on stage monitoring Monitor Speakers 6 x EM Acoustics M10 floor monitors 2 x EV SX 200 speakers (plus 2 stands) Multicores 32/4 analogue multicore installed running to stage left from stalls mixer position Cat5e UTP multicore reel 50m can either run to Stage left (preferred) or stage right 12 Channel XLR Satellite box 1 x 12 Channel Return cable. (Used for L, R, Mono, Monitors) 2 x 12 Channel Send cable Playback 2 x Denon CD player 2 x Tascam Minidisk player 1 x Apple Mac pro with Qlab 3 Headphones 1 x Beyerdynamic DT100 1 x AKG K55 Updated November 2017 Page 11
12 Power Downstage left 1 x 32a single phase audio power Selection of 32a to 16a step down distribution boxes Selection of 16a to 13a step down distribution boxes Selection of 32a and 16a cable. Selection of 13a extensions A good selection of microphones, cables, D.I boxes, adaptors, stands and other equipment is available. Please contact the Production Department in advance if you require any specific details of our stock. Projector/Lens/Rigging: Panasonic PT-DZ13KEJ projector Panasonic ET-D75LE :1 lens Panasonic ET-RFD91 projector cradle KPM flying bracket Cabling / Distribution: DATA PROJECTOR AND SCREEN 1x CYP PU-507TX-1H 1:1 HDBaseT HDMI/LAN/IR/RS-232/PoE Twisted Pair Transmitter with HDMI Loop (Max. 100m at 1080p or 4K;1 x HDMI input; 1 x HDBaseT, 1 x HDMI output) 1x 45m run of Kramer C-HDK6/HDK6-150 RJ-45 Four-Pair U/FTP Cable (23AWG) Optimized for HDBaseT 1x 4.6 m Kramer C-DPM/HM-15 DisplayPort to HDMI (M-M) Assorted VGA runs (50m) 1x Roland V-4EX Vision Mixer Screen: Stumpfl Monoblox 64 Front / Rear Projection Screen & Frame (16 x 9 / 5m x 3.8m) Please contact the Production Department to check availability. Updated November 2017 Page 12
13 Appendix A Updated November 2017 Page 13
14 Updated November 2017 Page 14
15 Updated November 2017 Page 15
16 Updated November 2017 Page 16
The Haymarket Basingstoke Technical Specifications
The Haymarket Basingstoke Technical Specifications The Haymarket Wote Street Basingstoke Hampshire RG21 7NW 01256 819797 Administration 01256 844244 Box office 01256 331733 Fax For further information
More informationThe Anvil Technical Specifications
The Anvil Technical Specifications The Anvil, Churchill Way, Basingstoke, Hampshire, RG21 7QR Technical Services Administrator: T: 01256 819797 Ext 164 (Avail 08:00 16:00 Mon-Fri) E: kate.weston@anvilarts.org.uk
More informationRPAC REDLANDS PERFORMING ARTS CENTRE
RPAC REDLANDS PERFORMING ARTS CENTRE CONCERT HALL Technical Specifications STAGE FACILITIES Soft Proscenium Theatre mode (see stage masking) Concert Platform (open area with acoustic walls on PS, OP and
More informationTheatre Technical Specifications
The Esplanade, Weymouth, Dorset, DT4 8ED 01305 783225 Theatre Technical Specifications Created by David Tozer, Technical Manager. dave@weymouthpavilion.com 1 of 10 Updated November 2015 The Theatre The
More informationMain House Technical Specification
Main House Technical Specification Technical Stage Manager: Assistant Technical Stage Manager: Nearest train station: Christchurch Population: 47,300 Distance to London: 105 miles Shaun Luckly Tel: 01202
More informationTechnical Specification
Contact us technical@lutonculture.com General Facilities Seating Capacity 238 on raked seating with centre aisle Stage Dimensions 6.4m deep x 8m wide Height of grid 4.2m Height of stage from the auditorium
More informationDEREHAM MEMORIAL HALL
DEREHAM MEMORIAL HALL is a multi purpose venue incorporating a 294 seat proscenium arch theatre. A standard stage, lighting and sound rig as set out below will be provided, unless otherwise agreed. Any
More informationO Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway
O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway INCOMPLETE AS OF 09-04-2017 DRAFT PURPOSES ONLY 1 of 13 Contents Contents Pg 2 Address Pg 3 Staff Pg 3 Telephone
More informationTechnical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3
Sound Console: Soundcraft Si Performer 3 32 mono mic inputs 80 channels to mix Freely assignable faders and patching Colour backlit LCD screens per fader 20 sub-group / aux busses 8 Matrix busses LCR panning
More informationDr JOHN GALLAGHER CONCERT CHAMBER
1 TECHNICAL SPECIFICATIONS Dr JOHN GALLAGHER CONCERT CHAMBER STAGE DIMENSIONS 12.5m wide at the downstage edge tapering to 10.7m wide at the far upstage wall. 8m in depth Elevated 0.9m from main auditorium
More informationTheatre Technical Specification
Theatre Technical Specification The information contained in this specification details the standard technical provision offered by the Brewhouse for visiting companies, artists and hirers. It details
More informationMatt Dann Cultural Centre
Matt Dann Cultural Centre Matt Dann Theatre Technical Specifications 13/07/09 Technical Manager: Brad Holder Phone number: 08 9158 9369 Mobile Number: 0447 632 936 Fax number: 08 9172 2472 Email address:
More informationThe Tower Theatre Contact - Peter Heselden Theatre Manager Tel
The Tower Theatre Contact - Peter Heselden Theatre Manager Tel- 07711710925 Email- pjwh15@msn.com The Tower Theatre has a seated capacity of 285 in the auditorium with 6 wheel chair positions. The box
More informationNew Theatre Royal Lincoln Technical Information
1 New Theatre Royal Lincoln Technical Information Please note that some items on our tech spec are subject to a recharge. Please contact Steve Chambers the Technical Manager on 07985 275522 or email technical@newtheatreroyallincoln.com
More information2017 TECHNICAL SPECIFICATIONS
2017 TECHNICAL SPECIFICATIONS Venue Address: Shirley Burke Theatre 64 Parkers Road, Parkdale Victoria 3195 SBT Theatre Coordinator: Tracey Kean Phone number: 9580-4998 Mobile number: 0400-657-987 tracey.kean@kingston.vic.gov.au
More informationTechnical Specifications Nov 2016
Technical Specifications Nov 2016 November 2016 1 Cambridge City Centre is a bicycle friendly city. There is short stay car parking in the area of the city, but all of it is expensive for a day stay. The
More informationCHELSEA THEATRE. Technical Specifications
CHELSEA THEATRE Technical Specifications DIMENSIONS Stage depth From setting line to back wall From front of seats to back wall Width of stage Grid height 6600mm 7200mm 9600mm 3800mm Auditorium Capacity
More informationTechnical Specification
Braintree Arts Theatre Notley Road Braintree Essex CM7 1WY t: 01376 556354 e: enquiries@braintreeartstheatre.com Technical Specification Theatre and Technical Manager: Phil Pattie phil.pattie@braintreeartstheatre.com
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS September 2017 TECHNICAL CONTACTS Technical Manager Clive Stevenson 01865 319451 stevensonc@thenorthwall.com Stage Manager Rebecca Welburn 01865 319451 welburnr@thenorthwall.com
More informationSR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.
TECHNICAL INFORMATION MAIN HOUSE STAGE DIMENSIONS The main stage is a flat floor sprung hardboard stage with a proscenium opening of 10.5m x 9.1m depth. The proscenium height is variable by the house border
More informationTechnical Specifications
Technical Specifications Updated Curatorial Statement is a Page 2 of 14 Theatre Stage Description: The Theatre is a flat floor space on the First Floor of the former Geelong Law Courts with 128 seat retractable
More informationUNIVERSITY CONCERT HALL. Technical Specification
UNIVERSITY CONCERT HALL Technical Specification Auditorium Total Seating 1,039 Seating breakdown Ground Floor 795 Balconies 191 Choir Stall 53 Wheelchair lift to four disabled positions Stage Performing
More informationJERWOOD VANBRUGH THEATRE
JERWOOD VANBRUGH THEATRE HIRES INFORMATION PACK 2013 Contact: +44 (0)20 7908 4822 bookings@radaenterprises.org GENERAL INFORMATION The most famous and most prestigious centre for drama training in the
More informationTechnical Specification. Updated: April 2016
Technical Specification Updated: April 2016 Venue Address: The Core at Corby Cube Parkland Gateway George Street Corby Northants NN17 1QG Contact: Andy Swinney Technical Manager Tel: 01536 470475 Email:
More informationETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers
PAVILION THEATRE TECHNICAL INFORMATION LIGHTING Permanent fixed lighting rig on fixed dead hung internally wired bar consisting of a 4 colour wash (Lee filters 106 Primary Red, 119 Dark Blue, 105 Orange
More informationINFORMATION FOR VISITING COMPANIES
INFORMATION FOR VISITING COMPANIES 2 Middlesbrough Theatre The Avenue Linthorpe Middlesbrough TS5 6SA ADMINISTERED BY MIDDLESBROUGH COUNCIL CULTURAL SERVICES Touring Drama, Dance, Music and Opera, Amateur
More informationTECHNICAL SPECIFICATION
Wyvern Theatre Theatre Square Swindon SN1 1QN Admin: 01793 535534 Ticket Office: 01793 524481 TECHNICAL SPECIFICATION Access & Parking: The Loading Dock and Stage Door are located at the end of Islington
More informationTechnical Specification for the Alley Theatre, Strabane
Technical Specification for the Alley Theatre, Strabane All technical requests should be made to Andrew Orr, Technical Officer. Contact Details Andrew Orr The Alley Theatre, Railway St, Strabane, BT82
More informationEquipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay
Equipment Inventory Seating Massey Theatre is a fully equipped, 1260 seat facility with 867 seats in the orchestra and the remainder in the balcony. Stage - Black Marmoleum (battleship linoleum) surface
More informationAuditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS
Auditorium Seating The Visy Theatre is a versatile venue with many configurations. The standard venue hire includes the venue in standard mode with a capacity of 200. The table and diagram below detail
More informationISLAND HALL TECHNICAL INFORMATION
ISLAND HALL TECHNICAL INFORMATION Lagan Valley Island, The Island, Lisburn, BT27 4RL Telephone: 028 9250 9250 (Reception) If you have any queries regarding this technical information please contact either:
More informationArlington Arts Tech Spec 2018
Arlington Arts Tech Spec 2018 Summary The Arts centre consists of the main house which is 250 seats end on format with raked seating. The first five rows are retractable bleacher style seating. There are
More informationTheatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:
Theatre SPECIFICATIONS UPDATED: 13/08/13 ADDRESS: 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: 08444068666 FAX: 08444068667 TECHNICAL MANAGER: E MAIL: JAKE SUTTON JAKES@LIGHTHOUSEPOOLE.CO.UK GENERAL
More informationDubbo Regional Theatre & Convention Centre Theatre Technical Specifications
Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications Updated: April 2018 Technical & Production Coordinator: David Brown Phone number: 0268014372 Fax number: 0268014259 Mobile: 0418270500
More informationMain House Technical Specifications
Main House Technical Specifications Technicians Senior Technician - Stephen Payne Technician - Drew White Technician - Joanne Marshall Arena Theatre Wulfruna Street Wolverhampton WV1 1SE Tel: 01902 321
More informationPleasance London Main House Visiting Company Information Pack May 2017
Pleasance London Main House Visiting Company Information Pack May 2017 Contact List Director Anthony Alderson anthony@pleasance.co.uk General Manager Hamish Morrow hamish@pleasance.co.uk Head of Comedy
More informationLatrobe Performing Arts Centre
Latrobe Performing Arts Centre Traralgon Town Hall Technical Specifications Updated 24/5/07 Technical Manager: Phone number: 03 5176 3426 Mobile Number: 0428 378 121 Fax number: 03 5176 3426 Email address:
More informationCornerstone Technical Specifications 2018 / V1
Cornerstone Technical Specifications 2018 / V1 Cornerstone is a purpose-built, professional arts, culture and entertainment venue in the heart of Didcot, brought to you by South Oxfordshire District Council.
More informationTechnical Specifications
Technical Specifications Technical Manager: Kevin Wilkins kbw@canford.com 01202 847543 Theatre Administrator layardtheatre@canford.com 01202 847529 All equipment is subject to availability. Please check
More informationBURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008
BURDEKIN THEATRE BURDEKIN THEATRE Technical Specifications Updated 08/02/2008 Technical Manager: David Bourke Phone number: 0747 839 888 Mobile Number: 0417 637190 Fax number: 0747 839 889 Email address:
More informationStage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m
Main House Technical Specification Get In Access for loading and unloading is via St Stephen s goods yard into the Hull Truck loading bay. Flat access at Stage Level for HGV s, backing directly onto main
More informationThere are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.
Technical Specification Adrian Sweeney Technical and Buildings Manager Office: 01483 739063 Stage Door: 01483 739040 Email: asweeney@glive.co.uk Web: GLive.co.uk 1. Auditorium Capacity Fully seated with
More informationMONASH University Academy of Performing Arts
MONASH University Academy of Performing Arts ROBERT BLACKWOOD HALL Technical Specifications Matthew King Technical Manger Phone number: (03) 9905 1689 Email address: matthew.king@monash.edu Updated December
More informationDarlington Hippodrome Technical Specification
Darlington Hippodrome Technical Specification 1. Introduction 2. H&S 3. Contact Us 4. Stage 5. Flying 6. Drapes, Masking 7. Stage Management 8. LX control, dimmers, Stock, Aux power 9. Sound 10. Control
More informationStage. Get In & Parking
Stage Capacity Stage Rigging Masking Auditorium 230 seats or 216 seats if front row removed. Wheelchair positions front row and upper auditorium right. Raked seating upper & lower house. 9.45m wide x 6.9m
More informationTechnical Director of Production Andrew Quick Ext 252
Technical Specification NST City April 2018 General Information Address NST City 144 Above Bar St Southampton SO14 7DU Contact Information Administration: 023 8031 5500 Box Office: 023 8067 1771 info@nstheatres.co.uk
More informationEquipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay
Equipment Inventory Seating Massey Theatre is a fully equipped, 1260 seat facility with 867 seats in the orchestra and the remainder in the balcony. Stage - Black Marmoleum (battleship linoleum) surface
More informationStage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.
Technical Specifications: Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used. Proscenium Opening Height: 16 ft. Width: 36 ft. Drapes in, approx.
More informationNEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY
NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY VICTORIA THEATER TECHNICAL SPECIFICATIONS Correct as of 11.08.07 Page 1 of 7 LOAD IN The Victoria Theater stage is directly accessible via loading dock
More informationStandard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)
AUDITORIUM PERFORMANCE AREA Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black) Standard (with THRUST seating) 6.1m Wide
More informationTheatre Technical Specifications
Theatre Technical Specifications The Lakes Theatre STAGING INFORMATION Seating Capacity: Total 1200 seats Stage Dimensions: Width at widest Part 18m Rear stage width- 13m Stage depth (at centre) 7.4m Height
More informationEsso BHP Billiton Wellington Entertainment Centre
Esso BHP Billiton Wellington Entertainment Centre John Leslie Theatre Technical Specifications Updated July 2008 Technical Manager: Brendan Peters Phone number: 03 5143 2511 Mobile Number: 0417 166 159
More informationW.L. LYONS BROWN THEATRE TECH PACK. Under the Management of
Under the Management of Theater Location 315 West Broadway Louisville, Kentucky 40202-2105 THEATRE STAFF Vice President of Operations: Chuck Schmidt (502) 566-5113 Facility Rental: Brandy Leitner (502)
More informationMERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.
MERMAID ARTS CENTRE Outline Technical Specifications as of 17 th January 2018. At Mermaid we are regularly upgrading our inventory. Please ensure you have a current version of this document. Note: Please
More informationTechnical Pack. Attenborough Arts Centre
Technical Pack Attenborough Arts Centre 1 Introduction This pack is designed to offer the user a detailed overview of the technical capabilities that the Attenborough Arts centre is able to provide. This
More informationConcert Hall Technical Specifications
Concert Hall Technical Specifications Revised 12-14-2017 4132 East Pecos Road Gilbert, AZ 85295 Phone: (480) 279-7190 Fax: (480) 279-7590 Website: www.higleyarts.org HCPA Overview The Higley Center for
More informationJohn Leslie Theatre. Technical Specifications. Updated July 2018
John Leslie Theatre Technical Specifications Updated July 2018 Generated from the APACA Technical Specifications Template. For more details visit www.apaca.com.au Coordinator Operations: Brendan Peters
More informationHarbourfront Centre Theatre Technical Specifications As of Jan. 2018
GENERAL THEATRE INFORMATION: Stage Floor: Dance Floor: HALL: Standard Stage: Sprung hard wood, painted black. Pit area: Nivoflex adjustable risers, hardwood ply top. Pit area is not sprung. Note: Neither
More informationTechnical Specification Ardhowen Theatre
Technical Specification Ardhowen Theatre Stage Proscenium Width Depth Forestage Height Stage Floor Flying System Stage Manager Orchestra Pit House Curtains Masking Cyclorama 8.6M (28.2ft) wide by 5.3M
More informationTECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER
Updated: June 27, 2011 TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER TELEPHONE NUMBERS: General Administrative Offices 253.591.5890 Production Stage Manager 253.591.5898 Facsimile 253.591.2027
More informationRhodes Arts Complex Bishops Stortford. Technical Specifications
Rhodes Arts Complex Bishops Stortford Technical Specifications Auditorium Seats up to 299 on retractable raked seating including balcony and 4 optional flat rows at floor level. At capacity there is a
More informationConcert Hall Technical Specifications
Concert Hall Technical Specifications Revised 11/1/2014 4132 East Pecos Road Gilbert, AZ 85295 Phone: (480) 279-7190 Fax: (480) 279-7590 Website: www.higleyarts.org HCPA Overview The Higley Center for
More informationTechnical specifications Main theatre. Sound
Sound Console: Soundcraft Si Performer 3 32 mono mic inputs 4 stereo line inputs 4 stereo Lexicon effects engines Stagebox: Soundcraft Mini Stagebox 32R 32 analogue inputs 8 analogue outputs 4 AES Out
More informationTechnical Specification Pavilion Dance
Technical Specification Pavilion Dance Contact Information Position Name Email Phone Number Technical Manager Technician Neil Kingston Louise Buckton neil@pdsw.org.uk louiseb@pdsw.org.uk 01202 203630 01202
More informationSummary. Access and Parking
1 Summary Cornerstone arts centre consists of the main house which is 217 seat end on format with raked seating. An extra row (AA) of flat floor seating can be added giving a capacity of 234. The stage
More informationFestival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy
Festival City Theatres Trust Festival Theatre Technical Specification Smoking Policy It is the policy of Festival City Theatres Trust that all of our workplaces are smoke-free and all employees and visiting
More informationTechnical Information
Technical Information The Berry Theatre Wildern Lane Hedge End Hampshire SO30 4EJ theberrytheatre@eastleigh.gov.uk 01489 783 473 ext 253 (The Berry Theatre Office) 023 8062 7803 (The Point Technical) www.theberrytheatre.co.uk
More informationPerforming Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)
1 Seating Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI 49544 Phone: (616) 647-0939 Fax: (616) 647-0149 Technical Specifications As of June 2009 Total Seating Capacity 756 + 4 wheelchair spaces
More informationShouson Theatre Venue Specifications (updated Jan 2017)
Shouson Theatre Venue Specifications (updated Jan 2017) Shouson Theatre is the largest venue in HKAC with capacity 439 seats. The proscenium theatre offers superb views from every seat, which audiences
More informationHIRE AND TECHNICAL INFORMATION
HIRE AND TECHNICAL INFORMATION 2 Table of Contents Stage Information... 3 Accommodation... 4 Lighting Equipment... 5 Sound Equipment... 7 In-House Cloths... 8 Stage Plan... 9 Contact Information.. 10 Parking
More informationHalf seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.
ANVIL CENTRE THEATRE S technologically advanced, flexible space is ideal for performing arts productions, dance recitals, music shows, digital and analog presentations, cabarets, banquets, and business
More informationTechnical Specifications and Inventory Spring 2018
African American Performing Arts Center Technical Specifications and Inventory Spring 2018 Annette Caine, Executive Director 505-222-9756 annette@aapacnm.org James Lewis, Facility Manager 505-222-0778
More informationMAIN THEATRE TECHNICAL SPECIFICATION
Alcester Street, Redditch, Worcestershire, B98 8AE MAIN THEATRE TECHNICAL SPECIFICATION Updated 28 th February 2018 Administration 01527 61544 Select department from the options Box Office 01527 65203
More informationADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION
ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION Stage Stage Dimensions: Theater dimensions: Mainstage - 60 0 wide x 28 9 deep. Proscenium arch - 41 6 wide x 28 0 tall. Load gallery on SR
More informationBackstage Accommodation (Ground Floor Mezzanine Level 1 Floor above Loading Bay)
General Get-In Loading Bay 300mm above road level via ramp, with sectional up & over door.79m wide x 3.7m high. Internal dims 15m long x 3.m wide x 4.1m high, plus further storage area approx..4m long
More informationTHE STREET THEATRE. Technical Specifications
THE STREET THEATRE Technical Specifications Updated 02/03/10 Technical Coordinator: Gillian Schwab Phone number: 02 62471519 Fax number: 02 6247 3808 Email address: gillians@thestreet.org.au Program Manager:
More information* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.
Technical Information Centerville Performing Arts Center Centerville High School 500 E. Franklin Street, Centerville, OH 45459 Theatre Manager: Mike Cordonnier Office: 937-439-3535, Fax: 937-439-3574 E-Mail:
More informationTechnical Specification
Technical Specification Address: The Mill Arts Centre Spiceball Park Road Banbury OX16 5QE Website: www.themillartscentre.co.uk Telephone: Box Office: (01295) 279002 Head of Technical and Production: Dan
More informationSOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5
Lighting -Lighting control PC with Horizon software and a 24 sub master wing. 2 Universes of DMX distributed via PathPort nodes. Our standard rep plot features 2 full stage back light washs of 20 PAR 64
More informationAnvil Theatre. Technical Information
Anvil Theatre Technical Information Seating Anvil Theatre has a variable seating configuration system. This allows for 4 different seating configurations: - Full Seating, gives a standard theatre style
More informationYan Yean Theatre Technical Specifications
Yan Yean Theatre Technical Specifications Updated 14/7/2017 STAGE DETAILS Brief Stage Description: Unraked stage with a proscenium arch and flying facilities. Structural plywood floor covered with masonite
More informationTechnical Data Sheet
Technical Data Sheet Pentas 2 The Kuala Lumpur Performing Arts Centre (klpac) Updated: 15 th July 2017 Table of Contents 1. General - Stage - Back Stage / Stand-by Area - Dressing Rooms - Security 2. Staging
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS MAIN HOUSE TECHNICAL SPECIFICATION LIGHTING ETC ION lighting desk with 2x 20 fader bank (NB this is an XP ION) 126 ways of dimming supplied by LSC digital dimmer packs. All outlets
More informationThere are 10 dressing rooms in Theatre Kerkrade.
Theatre Kerkrade Dressing rooms: There are 10 dressing rooms in Theatre Kerkrade. nr1. ± 3 persons douche and toilet ±7,5m 2 Ground Level nr2. ± 2 persons douche and hand basin ±6m 2 first floor nr3. ±
More information20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)
Technical Information Stage: Proscenium arch with apron SL Wall - SR Wall: 14.99m Setting Line - U/S Fly Bar: 7.57m Setting Line (under pros, DS edge when orchestra pit out) Back Wall: 8.17m Proscenium
More informationAccess to back stage is off Fletcher St on the eastern side of the building
BYRON TECHNICAL SPECIFICATIONS JUNE 2013 VENUE OVERVIEW A studio style theatre with a capacity of 246, this venue is as pleasurable for performers as it is for the audience. The theatre is an ideal space
More informationHopgood Theatre NOARLUNGA CENTRE
Hopgood Theatre NOARLUNGA CENTRE TECHNICAL FACILITIES Technical Manager: 0402 574 694 (M) Ramsay Place, PO Box 747 Noarlunga Centre, SA 5168 Box Office: (08) 8207 3977 Administration: (08) 8207 3975 Fax:
More informationCompass Theatre - Technical Information Pack
Compass Theatre - Technical Information Pack Compass Theatre, Glebe Avenue, Ickenham, Middlesex, UB10 8PD 01895 277634 CONTENTS Compass Theatre Technical Information Pack Venue and Contact Information
More informationStage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.
Technical specifications STAGE Brief stage description Stage one: With retractable seating out, unraked stage without a proscenium arch or fly tower (10 metre ceiling). Surface hardwood floor covered with
More informationThe performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.
TECHNICAL RIDER Company: WINTER GUESTS Performance: Simulacrum This rider should be included in the contract when the performance is booked, and any deviations must be clarified with technical manager
More informationMAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014
Alcester Street, Redditch, Worcestershire, B98 8AE MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014 Administration 01527 61544 Select department from the options Box Office 01527 65203 For
More informationTechnical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie
Braintree Arts Theatre Notley Road Braintree Essex CM7 1WY t: 01376 556354 e: enquiries@braintreeartstheatre.com Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie phil.pattie@braintreeartstheatre.com
More informationSHUBERT THEATER 247 College Street, New Haven, CT
SHUBERT THEATER 247 College Street, New Haven, CT 06510 203-624-1825 TECHNICAL SPECIFICATIONS and EQUIPMENT INVENTORY HALL SEATING CAPACITY Orchestra 665 Mezzanine 474 Balcony 392 Boxes 60 TOTAL 1591 STAGE
More informationCapacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs
Capacity: 60 2 Roxburgh Place, EH8 9SU Assembly Roxy - Downstairs Schedule C Outline description of the stage and technical facilities provided by Assembly. 1. SEATING is an end on theatre space with a
More informationTechnical Specifications
Technical Specifications A3 Arena only Forest Arts Centre Hawbush Road Walsall WS3 1AG 01922 654555 Flexible multifunction space with extensive self-supporting truss structure for rigging of technical
More informationCENTRE FOR PERFORMING ARTS
CENTRE FOR PERFORMING ARTS Venue, Facilities & Equipment CPA VENUE AREA SIZE FUNCTION Dressing Room (Female) 6 x 12m Dress and makeup room with attached toilet and shower facilities Dressing Room (Male)
More informationTechnical Information
Technical Information For more information please call Booking Agent and Manager: James Marsh 781-586-6770 General Information www.lynnauditorium.com The Lynn Memorial Auditorium is located in historic
More informationStage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Access door to stage from scene dock - 2.9m by 2.9m.
Technical specifications STAGE Brief stage description Stage one: The Cube is a flat floor, multipurpose space with a retractable seating bank and balcony seating. There is no proscenium arch or fly tower
More informationTechnical Services and Specification
Technical Services and Specification BRAUNTEX PERFORMING ARTS THEATRE ASSOCIATION, INC. 290 West San Antonio New Braunfels, TX 78130 (830) 627-0808 FAX (830) 627-0809 Operations Manager: Ben Nowotny -
More informationQueensland Performing Arts Centre
Queensland Performing Arts Centre CREMORNE THEATRE Technical Specifications Updated 03/12/08 Technical Manager: Chris Philippi Phone number: +61 7 3842 9127 Fax number: +61 7 3846 5768 Email address: chris.philippi@qpac.com.au
More information