1 LEMO FLUIDIC / PNEUMATIC CONNECTORS WITH VALVE FOR B AND K SERIES PLUS ADDENDUM FOR FLUIDIC / PNEUMATIC WITHOUT VALVE

2 1

3 LEMO Fluidic / Pneumatic Connectors This catalog gives an overview of monofluidic and hybrid mixed electrical and fluidic / pneumatic connectors. The modular pieces and Swiss precision manufacturing program gives a diverse and wide range of options and configurations. The foundation LEMO B series (indoor IP50 applications) and LEMO K series (outdoor IP68 applications) give a wide range of plug and receptacle housing configurations. Sizes range from the small size 00 monofluidic to size 5 in both the B and K series. Table of Contents Material and Treatment...Inside cover Precision Modular Connections...2 P1 & P3 Fluidic / Pneumatic with shutoff valves...3 European Recommended Tubing/Hose...3 2B & 5B Series...5 Part Numbering Example...6 2K & 5K Series...7 Part Numbering Example...8 Fluidic insert configurations for B & K series Collets for B & K Series Addendum: Fluidic / Pneumatic Without Valve

4 Precision modular connectors to suit your application Since it s creation in Switzerland in 1946 the LEMO Group has been recognized as a global leader of circular Push-Pull connectors and connector solutions. Today LEMO and its affiliated companies, REDEL and COELVER, are active in more than 80 countries with the help of over 40 subsidiaries and distributors. Over connectors The modular design of the LEMO range provides over connectors from miniature ø 3 mm to ø 50 mm, capable of handling cable diameters up to 30 mm and for up to 106 contacts. This vast portfolio enables you to select the ideal connector configuration to suit almost any specific requirement in most markets, including medical devices, test and measurement instruments, machinery, audio video broadcast, telecommunications and military. LEMO s Push-Pull Self-Latching Connection System This self-latching system is renowned worldwide for its easy and quick mating and unmating features. It provides absolute security against vibration, shock or pull on the cable, and facilitates operation in a very limited space. The LEMO self-latching system allows the connector to be mated by simply pushing the plug axially into the receptacle. Once firmly latched, connection cannot be broken by pulling on the cable or any other component part other than the outer release sleeve. When required, the connector is disengaged by a single axial pull on the outer release sleeve. This first disengages the latches and then withdraws the plug from the receptacle. UL Recognition LEMO connectors are recognized by the Underwriters Laboratories (UL). The approval of the complete system (LEMO connector, cable and your equipment) will be easier because LEMO connectors are approved. CE marking CE marking means that the appliance or equipment bearing it complies with the protection requirements of one or several European safety directives. CE marking applies to complete products or equipment, but not to electromechanical components, such as connectors. RoHS LEMO connectors are in compliance with the RoHS directives (2002/95/EC) of the European Parliament. This directive specifies the restrictions of the use of hazardous substances in electrical and electronic equipment marketed in Europe. LEMO guarantees that its connectors are free of mercury, cadmium, lead, hexavalent chromium and polybromide biphenyl (PBB) or polybromide diphenyl ether (PBDE). 2

5 P1/P3 Fluidic contact with valve The P1 fluidic contact is designed to fit multi fluid connectors or mixed fluid/electrical connectors from 2B to 5B and 2K to 5K series. This new design includes a shut-off valve. It fits into all insert cavities that already accept the LEMO coaxial type «C» of contact. The P3 fluidic contact is designed to fit multi fluid connectors of the 5B and 5K series. Its main features are: contacts with shut-off valve maximum working pressure 6 bars stainless alloy body after mounting on tube, the contact is installed in the main insulator and retained with a metallic clip. The contact is fitted with FPM o-ring, it can be used with liquids or gas. Part Section Showing Internal Components Female contact Male contact tube support spring female sleeve o-ring clip female shutoff o-ring flow tube support spring clip male sleeve male shutoff o-ring Technical Characteristics Material and Treatment Mechanical and Environmental Body Valve Spring Clips O-ring Components Value Stainless steel Alloy CuNiZn Stainless steel CuBe FPM Characteristics Mating durability Temperature range Max. working pressure Air flow rate at 6 bars Water flow rate at 6 bars Air flow rate at 6 bars Water flow rate at 6 bars Value Cont. type Standard 1000 cycles P1/P3 IEC test 9a -20 C, +125 C P1/P3 6 bars P1/P3 50 l/min P l/min P1 210 l/min P l/min P3 Flow/pressure diagram P1 contact type Note: flow direction is always from female contact to male contact. 50 Flow rate AIR l/min 1.0 Flow rate WATER l/min Pressure (bars) Pressure (bars) Note: test carried out with a 2 mm inner diameter tube. Flow/pressure diagram P3 contact type 200 Flow rate AIR l/min 4.7 Flow rate WATER l/min Pressure (bars) Pressure (bars) 3

6 Known European hoses for P1 & P3 contacts Recommended tubing/hose Series 2B, 3B, 2K, 3K 2B, 3B, 2K, 3K 2B, 3B, 4B, 5B 2K, 3K, 4K, 5K Contact type P1 Diameter (mm) Outer ø Inner ø Supplier Material Color Working temperature Legris 1100P0400 Polyamide (nylon) White -20 C to 80 C Legris 1100P0401 Polyamide (nylon) Black -20 C to 80 C Legris 1025U Polyurethane Black -20 C to 70 C Legris 1025U Polyurethane Black -20 C to 70 C 5B, 5K P Legris 1100P0601 Polyamide (nylon) Black -20 C to 80 C 4

7 2B-5B Series The P1 fluidic contact has been designed to work in the 2B to 5B series. The P3 contact has been designed to work in the 5B series. The main features of these series are as follows: security of the LEMO Push-Pull self-latching system the alignment key (G, A L, Y and R) ensures excellent repeatability of performance during frequent matings the P1 fluid contact allows hybrid configuration in the 2B series and multi fluid up to 10 channels in the 5B series. The possible outer cable diameters range from 4.0 to 25 mm. Straight plugs Free receptacles Fixed receptacles Fixed receptacles PKG* EGG * * PFG* ECG* FNG* EHG* Plastic housing models Straight plugs Fixed receptacles * ENG* FGY* ENY* FGY* Model Description ECG Fixed receptacle, with two nuts, key (G) or keys (A L and R), (back panel mounting) EGG Fixed receptacle, nut fixing, key (G) or keys (A L and R) EHG Fixed receptacle, nut fixing, key (G) or keys (A L and R) with visible shell ENG Fixed receptacle with grounding tab, nut fixing, key (G or J), PEEK outer shell ENY Fixed receptacle with grounding tab, nut fixing, keys (Y), PSU or PPSU outer shell Straight plug, key (G) or keys (A L and R) and cable collet Straight plug, key (G) or keys (A L) cable collet and nut for fitting a bend relief Straight plug, key (G or J), cable collet, PEEK outer shell FGY Straight plug, keys (Y), cable collet FGY and PSU or PPSU outer shell Straight plug, keys (Y), cable collet and PSU or PPSU outer shell and nut for fitting a bend relief FNG Straight plug, key (G) or keys (A L and R) and cable collet with lanyard release PFG Fixed receptacle, with two nuts, key (G) or keys (A L and R) and cable collet (back panel mounting) Free receptacle, key (G) or keys (A L and R) and cable collet Free receptacle, key (G) or keys (A L) and cable collet and nut for fitting a bend relief PKG Fixed receptacle, nut fixing, key (G) or keys (A L and R) and cable collet * Not show in this catalog. Refer to our catalog unipole-multipole Certain models and certain alignment key may not be available in all series. Please consult us. 5

8 Part Number Example 2B P12 C L A D 72 Z Variant: see note 1) Model: (see examples below) Cable ø: (page 10) Series: (see examples below) Collet type: (page 10) Type: (page 8) Housing: (page 9) C = chrome-plated brass P = polysulfone LV contact type: (page 9) Insulator: L = PEEK.2B.P12.CLAD72Z = Straight plug with key (G), 2B series, mixed type to accept one P1 fluid contact and 4 low voltage electrical contacts, chrome-plated brass housing, PEEK insulator, 4 male solder electrical contacts, type D collet system to suit a 6.1 to 7.0 mm diameter cable, and a nut for fitting a bend relief. Note: Connectors are always delivered with fluidic contact. 1) The «Variant» position in the reference is used to indicate the presence of a collet nut for fitting the bend relief. The bend relief must be ordered separately (see page 13). Straight plug, key (G) or keys (A L and R) and cable collet Dimensions (mm) ~L Model Series A L M S1 S2 ~M 2B 3B 4B 5B S 2 S 1 Free receptacle, key (G) or keys (A L and R) and cable collet Dimensions (mm) ~L Model Series 2B 3B 4B 5B A L S1 S S 2 S 1 S 3 L max M EGG Fixed receptacle, nut fixing, key (G) or keys (A L and R) Dimensions (mm) Model Series A B e E L M S1 S3 ø B e E max S 1 EGG 2B EGG 3B EGG 4B EGG 5B EGG 5B 1) M15x M18x M25x M35x M35x Note: 1) with P3 contact. 6

9 2K-5K Series The P1 fluidic contact has been designed to work in the 2K-5K series. The P3 contact has been designed to work in the 5K series. The main features of these series are as follows: security of the LEMO Push-Pull self-latching system specially designed for outdoors applications. All these models are waterproof when mated and reach a protection index of IP 66-IP 68, according to the IEC standard the alignment key (G, A F, L and R) ensures excellent repeatability of performance during frequent matings the P1 fluidic contact allows hybrid configuration in the 2K series and multi fluid up to 10 channels in the 5K series. The 2K-5K series consists of ten models which will accept outer cable diameters ranging from 2.6 mm to 23.5 mm. Straight plugs Free receptacles Fixed receptacles * * EGG EEG* Fixed plug Fixed receptacles EBG* FXG* PKG* PEG* Model Description EBG Fixed receptacle with square flange, key (G) or keys (A F, L and R), four holes fixing EEG Fixed receptacle, nut fixing, key (G) or keys (A F, L and R) (back panel mounting) EGG Fixed receptacle, nut fixing, key (G) or keys (A F, L and R) Straight plug, key (G) or keys (A F, L and R), cable collet Straight plug, key (G) or keys (A F, L and R), cable collet and nut for fitting a bend relief FXG Fixed plug with round flange, four holes fixing, key (G) or keys (A F, L and R) PEG Fixed receptacle, nut fixing, key (G) or keys (A F, L and R), cable collet and nut for fitting a bend relief (back panel mounting) Free receptacle, key (G) or keys (A F, L and R), cable collet Free receptacle, key (G) or keys (A F, L and R), cable collet and nut for fitting a bend relief PKG Fixed receptacle, nut fixing, key (G) or keys (A F, L and R), cable collet and nut for fitting a bend relief * Not show in this catalog. Refer to our catalog unipole-multipole Certain models and certain alignment key may not be available in all series. Please consult us. 7

10 Part Number Example 3K P20 C L Z C 76 Z Variant: see note 1) Model: (see examples below) Cable ø: (page 10) Series: (see examples below) Cable fixing type: T = cable adapter Type: (page 8) LV Contact Type: (page 9) Housing: C = chrome-plated brass Insulator: L = PEEK.3K.P20.CLZC76Z = Straight plug with key (G), 3K series, multi fluid with 2 times P1 contacts, chrome-plated brass housing, PEEK insulator, C type collet for 7.5 mm diameter cable, and nut for fitting a bend relief. Note: Connectors are always delivered with fluidic contact. 1) The «Variant» position in the reference is used to indicate the presence of a collet nut for fitting the bend relief. The bend relief must be ordered separately (see page 13). Straight plug, key (G) or keys (A F, L and R), cable collet and nut for fitting a bend relief Dimensions (mm) L max Model Series A L M S2 M max A 2K 3K 4K 5K Note: The overall length dimension is with Desmopan bend relief S 2 Free receptacle, key (G) or keys (A F, L and R), cable collet and nut for fitting a bend relief Dimensions (mm) Model Series A L S2 L max 2K 3K 4K 5K S 2 Note: The overall length dimension is with Desmopan bend relief L max EGG Fixed receptacle, nut fixing, key (G) or keys (A F, L and R) S 3 M Dimensions (mm) Model Series A B e E L M S1 S3 B e A EGG EGG EGG EGG 2K 3K 4K 5K M20x M24x M30x M45x E max S 1 8

11 Insert configuration Multi fluid and Mixed fluid + LV 2B 2K 3B 3K 4B 4K Male solder contacts Male crimp contacts Female solder contacts Female crimp contacts P11 P12 P13 P15 P20 P22 P23 P25 P28 P40 P49 Nb of fluidic tube Fluidic contact Type Ext. ø of tube Int. ø of tube Max. working pressure (bars) Contact No (mm) 1 P P P P P P P P P Solder Low Voltage contact Contact Solder Crimp type contact contact Crimp Test voltage (kv rms) Contact-contact Test voltage (kv rms) Contact-shell Test voltage (kv rms) Contact-contact Test voltage (kv rms) Contact-shell 4 P P Rated current (A) P33 3 P P36 3 P P26 2 P P28 2 P P29 2 P

12 Multi fluid and Mixed fluid + LV Male solder contacts Male crimp contacts Female solder contacts Female crimp contacts Nb of fluidic tube Fluidic contact Type Ext. ø of tube Int. ø of tube Max. working pressure (bars) Contact No (mm) Solder Low Voltage contact Contact Solder Crimp type contact contact Crimp Test voltage (kv rms) Contact-contact Test voltage (kv rms) Contact-shell Test voltage (kv rms) Contact-contact Test voltage (kv rms) Contact-shell Rated current (A) 5B 5K P01 10 P P30 3 P P40 4 P Housings (B and K series) Ref. C G P Outer shell and collet nut Latch sleeve + earthing crown Other metallic components Remarks Material Surf. treatment Material Surf. treatment Material Surf. treatment Brass chrome brass/bronze nickel 2) brass nickel PEEK (natural) brass/bronze nickel 2) brass nickel Only for and ENG (B series) PSU brass/bronze nickel 2) brass nickel Only for FGY and ENY (B series) 1) Note: 1) see «variant» for the color. 2) in the K series, the latch sleeve is chrome-plated. Electrical Contact Contact for plug, receptacle, and fixed receptacle Ref. A C L M Z Contact type male solder male crimp female solder female crimp no contact 10

13 Collets (B and K series) D and M type collets for B series D type ø B M type Type Code Collet ø Cable ø ø B max. min. Notes Type Code Collet ø Cable ø ø B max. min. Notes 2B 3B M 42 D 52 D 62 D 72 D 82 D 92 D 99 M 52 D 62 D 72 D 82 D 92 D 10 D 11 D Note: 1) these collets cannot be used for connector models with nut for fitting a bend relief. All dimensions are in millimeters. 1) 1) 4B 5B M 62 M 72 M 82 M 92 D 10 D 12 D 13 D 15 D 16 D 11 D 13 D 15 D 17 D 19 D 21 D 23 D ) 1) 1) 1) 1) 1) 11

14 C and K type collets for K series C type ø B ø B K type oversize cable collet ø B ø B Collet ø Cable ø Collet ø Cable ø Type Code ø B max. min. Type Code ø B max. min. 2K 3K C 35 C 40 C 45 C 50 C 55 C 60 C 65 C 70 C 75 C 80 C 85 K 90 K 95 K 10 K 11 C 30 C 35 C 40 C 45 C 50 C 55 C 60 C 65 C 70 C 75 C 80 C 85 C 90 C 95 C 10 C 11 K 11 K 12 K 13 K 14 K 15 Note: all dimensions are in millimeters K 5K C 50 C 55 C 60 C 65 C 70 C 75 C 80 C 85 C 90 C 95 C 10 C 11 C 12 C 13 C 14 C 15 K 16 K 17 K 18 K 19 K 20 K 21 K 22 K 23 C 10 C 11 C 12 C 13 C 14 C 15 C 16 C 17 C 18 C 19 C 20 C 21 C 22 C Tools Extractor DCC.91.10P.1LA DCC.91.10P.3LA Contact type P1 P3 120

15 Variant (B and K series) Bend relief for B series models with collet Need to be ordered Bend relief for K series models with collet Need to be ordered Ref. Type Collet Code Need to be ordered separately Ref. Type Collet Code Need to be ordered separately 2B 3B 4B 5B Z Z Z Z M 42 D 52 to 92 M 52 D 62 to 11 M 62 and 72 M 82 and 92 D 10 to 15 D 11 to 15 GMA.2B.. GMA.2B.. GMA.1B.. GMA.3B.. GMA.2B.. GMA.4B.. GMA.4B.. GMA.4B.. 2K 3K 4K Z Z Z C 35 to 85 K 90 to 10 C 30 to 10 K 11 to 15 C 50 to 15 GM Bend relief (Polyurethane) L A bend relief made from thermoplastic polyurethane elastomer (Desmopan 786) can be fitted over LEMO plugs and receptacles that are supplied with nut for fitting such bend relief. They are available in nine different colors that match with the GRA insulating washers (see unipole-multipole catalog). Use the part numbers shown below to order this accessory separately. Note: All dimensions are in millimeters. GMA.2B.. GMA.3B.. GMA.3B.. GMA.4B.. GMA.4B.. Main characteristics Material: Polyurethane elastomer Temperature range in dry atmosphere: -40 C +80 C Part number GMA.2B.040.DG GMA.2B.045.DG GMA.2B.060.DG GMA.2B.070.DG GMA.3B.060.DG GMA.3B.070.DG GMA.3B.080.DG GMA.4B.011.DG GMA.4B.012.DG GMA.4B.013.DG Dimensions (mm) Bend relief Cable ø A L max. min Series 2B-2K 3B-3K 4B-4K-5B Ref. A B G J M Color blue white gray yellow brown Ref. N R S V Color black red orange green Note: the last letter «G» of the part number indicates the gray color of the bend relief. For ordering a bend relief with another color, see table above and replace the letter «G» by the letter of the required color. 13

16 Product safety notice PLEASE READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY AND CONSULT ALL RELEVANT NATIONAL AND INTERNATIONAL SAFETY REGULATIONS FOR YOUR APPLICATION. IMPROPER HANDLING, CABLE ASSEMBLY, OR WRONG USE OF CONNECTORS CAN RESULT IN HAZARDOUS SITUATIONS. 1. SHOCK AND FIRE HAZARD Incorrect wiring, the use of damaged components, presence of foreign objects (such as metal debris), and / or residue (such as cleaning fluids), can result in short circuits, overheating, and / or risk of electric shock. Mated components should never be disconnected while live as this may result in an exposed electric arc and local overheating, resulting in possible damage to components. 2. HANDLING Connectors and their components should be visually inspected for damage prior to installation and assembly. Suspect components should be rejected or returned to the factory for verification. Connector assembly and installation should only be carried out by properly trained personnel. Proper tools must be used during installation and / or assembly in order to obtain safe and reliable performance. 3. USE Connectors with exposed contacts should never be live (or on the current supply side of a circuit). Under general conditions voltages above 30 VAC and 42 VDC are considered hazardous and proper measures should be taken to eliminate all risk of transmission of such voltages to any exposed metal part of the connector. 4. TEST AND OPERATING VOLTAGES The maximum admissible operating voltage depends upon the national or international standards in force for the application in question. Air and creepage distances impact the operating voltage; reference values are indicated in the catalog however these may be influenced by PC board design and / or wiring harnesses. The test voltage indicated in the catalog is 75% of the mean breakdown voltage; the test is applied at 500 V/s and the test duration is 1 minute. 5. CE MARKING CE Marking is applied to a complete product or device, and implies that the device complies with one or several European safety directives. CE Marking can not be applied to electromechanical components such as connectors. 6. PRODUCT IMPROVEMENTS The LEMO Group reserves the right to modify and improve to our products or specifications without providing prior notification. 14

17 Addendum for Fluidic / Pneumatic Without Valve

18 Fluidics Connectors Series 00-B LEMO fluidic connectors find many applications in the medical, dental and other industries that require precise, dependable fluidic connections. Fluidic connectors may be of the monotube type available in the Series 00 and 0B or of the multitube type and/or mixed with electrical contacts available in the Series 2B, 3B and 4B. Mixed connectors combining fluidic and signal contacts are also available. Please see LEMO s Unipole Mulitpole catalog for more information. Fluidic connectors may also be sued in pneumatic applications. Contact LEMO USA for custom applications Interconnections Series 00 Series B Straight Plug Straight Receptacle Straight Plug Fixed Receptacle Straight Receptacles FFA PCA EGG PSA PKG Model Description Monofluidic (Series 00) FFA Straight plug with cable collet PCA Free receptacle with cable collet PSA Fixed receptacle, nut fixing, with cable collet Monofluidic (Series 0B) Straight plug with key (G) or keys (code A...M) and cable collet Free receptacle with key (G) or keys (code A...M) and cable collet PSA Fixed receptacle, nut fixing, with key (G) or keys (code A...M) and cable collet Multifluidic and Mixed (Series 2B-4B) EGG Fixed receptacle nut fixing, with key (G) or keys (code A...M) Straight plug with key (G) or keys (code A...M) and cable collet Free receptacle with key (G) or keys (code A...M) and cable collet PKG Fixed receptacle, nut fixing, with key (G) or keys (code A...M) and cable collet Part Section Showing Internal Components (Monofluidic Series 0B) Fixed Receptacle 1 shell 2 hexagonal nut 3 locking washer 4 collet nut 5 tube support 6 retaining ring Straight Plug 1 outer shell 2 latch sleeve 3 O-ring 4 collet nut 5 tube support 6 retaining ring Technical Characteristics Material and Treatment Mechanical and Climatic Component Outer shell and Collet nut Latching sleeve Tube support Retaining ring Locking washer Insulator Male contact Female contact O-ring Material (Standard) Brass (UNS C 38500) Aluminum ( AISI 6262) Special brass Brass (UNS C 38500) Brass (UNS C 38500) Bronze (UNS C 52100) PEEK (MIL-P ) Brass (UNS C 38500) Bronze (UNS C 54400) Silicone rubber Surface treatment (µm) Cu Ni Cr Au anodized Characteristics Max. working pressure Endurance Operating temperature Unit bar cycles C 00 2 Series 0B 2B 2 > (+5 F + 86 F) The surface treatment standards are as follows: Nickel FS-QQN-290A Chrome FS-QQ-C-320B 3B 0.5 Note: flow direction is always from female contact to male contact. 16

19 Part Number Example 0B 010 C Z Z N 50 Model: see below Series: 00/0B-2B-3B-4B Type: pages 18 and 19 Housing: C= chrome plated brass (standard) L= anodized aluminum 3 (on request) s= stainless steel (on request) Insulator: L= PEEK Z= without insulator 1 Variant 3 ø Tube or collet: page 11 Fixing type: D cable collet N tube support 1 Contact type: A male solder C male crimp L female solder M female crimp Z without contact 2.0B.010.CZZN50 Straight plug with key (G), 0B series, multifluidic; type fitted with one fluidic tube, chrome-plated brass outer housing, nickel plated brass tube support for a 5.0 mm OD tube. Notes: 1) For monofluidic (010) types only. 2) For monofluidic (010) and multifluidic (040) types only. 3) The variant position of the part number is used to indicate the anodizing color of aluminum shells. The colors available and their corresponding reference letters are to the right. Ref. A J N Anodizing color blue yellow black Ref. R T V Anodizing color red natural green Note: All dimensions are in millimeters. Series 00 FFA PCA PSA ~26 ~25 ~24,5 ø6,4 ø6,4 ø8 M7x0,5 Series B EGG PKG ~L ~L ~L øa øa øa e e ~L øa Model EGG EGG Dim. A L A e L A L A e L Series 0B 2B 3B 4B M15x1 M18x1M25x M9x0.6 M15x1M18x1 M25x

20 Types Fluidics and Fluidics + LV Fluidic Low Voltage (LV) Standard Group Watertight Group Number of Tubes O.D. of Tube I.D. of Tube I.D. of Contact Max. working pressure (bar) Number of Contacts Contact ø Contact type Solder Crimp Working Voltage (kv rms) Working Voltage (kv dc) Test Voltage (kv rms) Test Voltage (kv dc) Rated Current (A) Tube or Collet ø B 0K 2B 2K B 0K B 2K ) 2B 2K ) 015 2B 2K ) 1) Refer to the table for the diameters of the collets. 2) For the monofluidic connector types (00, 0B) this diameter indicates the outside diameter of the fluidic tube being fitted. Available On request All the B Series inserts may be used in our Environmental K Series. Please see our K/E catalog for shell configurations. 18

21 Types Fluidics and Fluidics + LV Fluidic Low Voltage (LV) Standard Group Watertight Group Number of Tubes O.D. of Tube I.D. of Tube I.D. of Contact Max. working pressure (bar) Number of Contacts Contact ø Contact type Solder Crimp Working Voltage (kv rms) Working Voltage (kv dc) Test Voltage (kv rms) Test Voltage (kv dc) Rated Current (A) Tube or Collet ø 2 3B 3K B 3K ) 3B 3K ) 025 3B 3K ) 040 3B 3K ) 042 3B 3K ) 4B 4K 026 4B 4K ) 028 4B 4K ) 049 4B 4K ) 1) Refer to the table for the diameters of the collets. 2) For the monofluidic connector types (00, 0B) this diameter indicates the outside diameter of the fluidic tube being fitted. Available On request All the B Series inserts may be used in our Environmental K Series. Please see our K/E catalog for shell configurations. 19

22 The brands of LEMO, are LEMO, REDEL and Coelver. The REDEL brand also has fluidic / pneumatic solutions, please see the REDEL catalog. For R series fluidic / pneumatic hybrid solutions please see the R series catalog 21

23 LEMO HEADQUARTERS SWITZERLAND LEMO SA Chemin des Champs-Courbes 28 - P.O. Box CH-1024 Ecublens Tel. (+41 21) Fax (+41 21) info@lemo.com LEMO SUBSIDIARIES AUSTRIA LEMO Elektronik GesmbH Lemböckgasse 49/E Wien Tel: (+43 1) Fax: (+43 1) sales@lemo.at CHINA LEMO Trading (Shanghai) Co., Ltd. LEMO Electronics (Shanghai) Co., Ltd. 5th Floor, Block 6, City of ELITE, 1000 Jinhai Road, Pudong Shanghai, China Tel: (+86 21) Fax: (+86 21) cn.sales@lemo.com DENMARK LEMO DENMARK A/S Gammel Mosevej Gentofte Tel: (+45) Fax: (+45) info-dk@lemo.com FRANCE LEMO FRANCE Sàrl 15/19 Avenue Graham Bell Espace Vinci-Bussy Saint Georges MARNE LA VALLEE Cedex 3 Tel: (+33 1) Fax: (+33 1) info-fr@lemo.com GERMANY LEMO Elektronik GmbH Hanns-Schwindt-Str München Tel: (+49 89) Fax: (+49 89) info@lemo.de HONG KONG LEMO Hong Kong Ltd. Room 33. 7th Floor HITEC, 1 Trademart Drive Kowloon Bay - Hong Kong Tel: (+852) Fax: (+852) hk.sales@lemo.com HUNGARY REDEL Elektronika Kft Vágóhíd u Budapest XX. Tel: (+36 1) Fax: (+36 1) info-hu@lemo.com ITALY LEMO ITALIA srl Viale Lunigiana 25, Milano Tel: (+39 02) Fax: (+39 02) sales.it@lemo.com JAPAN LEMO JAPAN Ltd , Takaido Higashi, Suginami-ku, Tokyo, Tel: (+81 3) Fax: (+81 3) lemoinfo@lemo.co.jp NETHERLAND / BELGIUM LEMO Connectors Nederland B.V. De Trompet DC Heemskerk Tel: (+31 0) Fax: (+31 0) info@lemo.nl NORWAY / ICELAND LEMO NORWAY A/S Stanseveien 6B, 0975 Oslo Tel: (+47) Fax: (+47) info-no@lemo.com SPAIN / PORTUGAL IBERLEMO S.A. Brasil, 45, Granollers Barcelona Tel: (+34 93) Fax: (+34 93) info-es@lemo.com Madrid Office Antonio López, Madrid Tel: (+34 91) Fax: (+34 91) SWEDEN / FINLAND LEMO Nordic AB Mariehällsvägen 39A Bromma Tel: (+46 8) Fax: (+46 8) info-se@lemo.com SWITZERLAND LEMO VERKAUF AG Grundstrasse 22B 6343 Rotkreuz Tel: (+41 41) Fax: (+41 41) ch.sales@lemo.com UNITED KINGDOM LEMO UK Ltd Unit 15 & 16 Hazelwood Trading Estate Worthing, West Sussex, BN14 8NP Tel: ( ) Fax: ( ) lemouk@lemo.com CAT.FL.LUS.P0209 LEMO USA, Inc info@lemousa.com

PLASTIC CONNECTORS R

PLASTIC CONNECTORS R PLASTIC CONNECTORS Precision modular connectors to suit your application Since it s creation in Switzerland in 1946 the LEMO Group has been recognized as a global leader of circular Push-Pull connectors

More information

QUALITY CONNECTION SOLUTIONS

QUALITY CONNECTION SOLUTIONS QUALITY CONNECTION SOLUTIONS Our vision To be market leader in the design and provision of quality custom connection solutions and a centre of excellence in electrical & fibre optic terminations. About

More information

7 N. F v : average latching force (without contact) 110 N. F a : average retention force (without contact) 9 N

7 N. F v : average latching force (without contact) 110 N. F a : average retention force (without contact) 9 N PLASTIC CONNECTORS Precision modular connectors to suit your application Since its creation in Switzerland in 1946 the LEMO Group has been recognized as a global leader of circular Push-Pull connectors

More information

Interconnections. General characteristics. Plug

Interconnections. General characteristics. Plug NEW Interconnections Sockets Sockets Plug General characteristics 0R and 1R series connectors provide the following main features: Security of the Push-Pull LEMO self-latching system Housing of composite

More information

HIGH SPEED MULTIPOLE CAT 6A CONNECTORS

HIGH SPEED MULTIPOLE CAT 6A CONNECTORS HIGH SPEED MULTIPOLE CAT 6A CONNECTORS Cat 6A connector The high speed connectors complete the line of 2B series connector. These new contact Specifications: Transmission performance meets Category 6A

More information

PL Series. Plastic Push Pull Interconnects

PL Series. Plastic Push Pull Interconnects PL Series Plastic Push Pull Interconnects We Connect When it matters most For more than a century, ITT Cannon has developed innovative interconnect solutions for the world s most critical applications.

More information

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces Automatic s 2004 Automatic. All rights reserved. pdf 1.0 3-18-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable Plugs...................

More information

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/ Connectors Introduction 2004 Automatic Connector. All rights reserved. pdf 1.0 4-13-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable

More information

Unipole and Multipole Connectors

Unipole and Multipole Connectors Unipole and Multipole Connectors Miniature Cylindrical Connectors With Push-Pull-Locking Shenzhen Medplus Connector Co.,Limited. 2 th Floor,Ming An Street,GongMing Town, Baoan District, Shenzhen, China

More information

Small Circular Connector. JN1W / JN2W Series

Small Circular Connector. JN1W / JN2W Series COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Small Circular Connector / Series CONNECTOR MB-0178-5 December 2012 Angle Plug Cable Connecting Straight Plug Wall Mount Cable Connecting Waterproof Cap

More information

SECTION 4 TABLE OF CONTENTS

SECTION 4 TABLE OF CONTENTS Contents Introduction LC, SC and ST Series...4-2 Markets and Applications...4-2 International Standard Documents Compliance...4-2 LC Series Features and Benefits...4-3 LC Standard... 4-4 to 4-5 LC for

More information

Small Circular Connector. JN1/JN2 Series. Dust Cap

Small Circular Connector. JN1/JN2 Series. Dust Cap COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Small Circular Connector JN1/JN2 Series Angle Plug CONNECTOR MB-0054-8 October 2009 [JN1] [JN2] [JN1] [JN2] Straight Plug Cable Connecting Individual Plug

More information

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors Amphenol Amphenol-Tuchel Electronics GmbH C 112 Series M12 - Connectors We connect con The company Amphenol-Tuchel Electronics is a worldwide leader in electrical connectors and contacting devices. Our

More information

TE Connectivity DEUTSCH DL Series MIL-DTL Series III Connectors

TE Connectivity DEUTSCH DL Series MIL-DTL Series III Connectors Applications Features TE Connectivity DEUTSCH DL Series MIL-DTL-83723 Series III Connectors High-performance military aircraft Commercial aircraft Communications equipment Armored personnel carriers &

More information

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS SERIES BNC 50, COAXIAL MINIATURE CONNECTORS DESCRIPTION CONTENTS PAGE HUBER+SUHNER BNC is still one of the most popular connector series, featuring a two stud bayonet coupling mechanism, which is particularly

More information

8D with High Frequency Coaxial Contact

8D with High Frequency Coaxial Contact 8D Series M Coaxial Contacts 8D with High Frequency Coaxial Contact robust and powerfull coaxial High Frequency transmission (M) now available in any size 8 SOURIU insert of D38999 Series III. Spring HF

More information

Type "N" Connectors. Type "N" Interface Dimensions

Type N Connectors. Type N Interface Dimensions Type "N" Connectors The type N series coaxial connectors were originally designed as medium-size low voltage constant impedance 50 OHM connectors. Type N connectors found immediate popularity for microwave

More information

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors PPLINCES /// MT, CST-100 II ND SL-156 CONNECTORS CONNECTORS/ PPLINCES MT, CST-100 II and SL-156 Connectors Contents Introduction This catalog has been designed to assist you, our customer, identify products

More information

ARINC 801 Fiber Optic Interconnects for Aerospace & Defense. A Complete End-to-End Solution Featuring Connectors, Termini & Cable Harnesses

ARINC 801 Fiber Optic Interconnects for Aerospace & Defense. A Complete End-to-End Solution Featuring Connectors, Termini & Cable Harnesses ARINC 801 Fiber Optic Interconnects for Aerospace & Defense A Complete End-to-End Solution Featuring Connectors, Termini & Cable Harnesses We Connect the Aerospace & Defense Industry with High-Speed Data,

More information

MaxiBridge mm Connectors. Ed Full-scale MaxiBridge 8 Pins Catalog E

MaxiBridge mm Connectors. Ed Full-scale MaxiBridge 8 Pins Catalog E MaxiBridge 2.54 mm Connectors Ed. 10 11.2014 Full-scale MaxiBridge 8 Pins Catalog E 074593 CABLE CONNECTOR SYSTEM GENERAL MaxiBridge Male and Female Connector The 2.54 mm single and dual row cable connector

More information

HDRFI Series Tensolite High-Performance Cable & Interconnect Systems. High Density RF Interconnect

HDRFI Series Tensolite High-Performance Cable & Interconnect Systems. High Density RF Interconnect HDRFI Series Tensolite High-Performance Cable & Interconnect Systems High Density RF Interconnect HDRFI is a patented Tensolite connection system that transfers high frequency signals through a unique

More information

Inductive sensor With analog output BI15-M30-LI-EXI

Inductive sensor With analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation

More information

SECTION 9 BNC/BNC 75 HDTV/BNC-TRX R141/R142/R266 SIMPLIFICATION IS OUR INNOVATON. Visit for more information

SECTION 9 BNC/BNC 75 HDTV/BNC-TRX R141/R142/R266 SIMPLIFICATION IS OUR INNOVATON. Visit   for more information SECTION 9 BNC/BNC 75 HDTV/BNCTRX R141/R142/R266 SIMPLIFICATION IS OUR INNOVATON Visit www.radiall.com for more information Contents BNC Introduction... 94 to 95 Interfaces... 96 to 97 Characteristics...98

More information

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.

More information

Interface RF Connector with Switch, built-in interlock, DC to 3GHz

Interface RF Connector with Switch, built-in interlock, DC to 3GHz Interface RF Connector with Switch, built-in interlock, DC to 3Hz MS-151NB Series Overview Designed for end user applications requiring redirection of transmission from internal built-in antenna to the

More information

SECTION 10 BNC / BNC 75 HDTV / BNC-TRX R141 / R142 / R266

SECTION 10 BNC / BNC 75 HDTV / BNC-TRX R141 / R142 / R266 SECTION 10 10 BNC / BNC 75 HDTV / BNC-TRX R141 / R142 / R266 Contents Introduction... 10-4 to 10-5 Interfaces... 10-6 to 10-7 Characteristics... 10-8 to 10-11 Finder guide...10-12 to 10-13 COMPOSITE BNC

More information

0.3 mm Pitch, 1.5 mm Mated Height, Board- to-fine Coaxial Cable Connectors

0.3 mm Pitch, 1.5 mm Mated Height, Board- to-fine Coaxial Cable Connectors All non-rohs products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales

More information

Horizontal or Vertical PCB contacts Bulk Packaging LED colour - Red, Green, Yellow or Blue combinations. Ordering Codes

Horizontal or Vertical PCB contacts Bulk Packaging LED colour - Red, Green, Yellow or Blue combinations. Ordering Codes XLRnet CONNECTORS XLRnet CONNECTORS XLRnet was designed in conjunction with the Amphenol Data / Telecom product group of Amphenol Canada Corp., a subsidiary of Amphenol Corporation. Utilising our combined

More information

The Custom Interconnect Leader TM

The Custom Interconnect Leader TM LC Series.5.188.685 ELECTRICAL Nominal Impedance: Frequency Range: Voltage Rating: Dielectric Withstanding Voltage: Insulation Resistance: VSWR: 50 ohms DC to 1.0 GHz 5,000 volts rms 3,000 volts rms 5,000

More information

Series MCX 50 micro miniature connectors

Series MCX 50 micro miniature connectors Series MCX 50 micro miniature connectors Description Content MCX 50 HUBER+SUHNER MCX micro miniature snap-on connectors offer you an excellent blend of size,weight, durability and performance for applications

More information

MCX Miniature Coaxial Connectors

MCX Miniature Coaxial Connectors ONLINE CATALOG MCX Miniature Coaxial Connectors 104 John W. Murphy Drive P.O. Box 510 New Haven, CT 06513 www.aepconnectors.com e-mail: aepsales@aepconnectors.com Mating Interfaces MCX Miniature Coaxial

More information

SUHNER QMA SUBMINIATURE CONNECTORS

SUHNER QMA SUBMINIATURE CONNECTORS SUHNER QMA SUBMINIATURE CONNECTORS Description Content Page SUHNER QMA coaxial connectors are available with 50 Ω impedance. The frequency range extends to 11 GHz, depending on the connector and cable

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

M-relays, 2, 3 or 4 pole, 7-12 A Datasheet

M-relays, 2, 3 or 4 pole, 7-12 A Datasheet , 2, 3 or 4 pole, 7-12 A Datasheet Features Compact plug-in design 2, 3 or 4 C/O contacts Standard mechanical indicator Flat and silver relay pins for excellent connection in socket Wide range sockets

More information

Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height

Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.4mm Mated Height Ultra Small Surface Mount Coaxial Connectors - Low Profile 1.9mm or 2.mm Mated Height U.FL Series Up to 6GHz Transmission Speed Mated Height Comparison (With E.FL series) 1.9(2.0Max) U.FL-LP(V)-00 2.(2.5Max)

More information

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics Amphenol C 6- / C 6- Circular Circular Connectors Connectors Amphenol-Tuchel Electronics General information We reserve the right to change the design due to improvement in quality, development or production

More information

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO. DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Output signals -wire: 4... 0 ma -wire:

More information

SMPTE COMPATIBLE HDTV CONNECTION SYSTEM 3K.93C SERIES

SMPTE COMPATIBLE HDTV CONNECTION SYSTEM 3K.93C SERIES SMPTE COMPATIBLE HDTV CONNECTION SYSTEM 3K.93C SERIES LEMO pioneered and set the standard for HDTV The global standard for HDTV fibre connector LEMO developed the 3K.93C Series connectors in the early

More information

EXPlora. Introduction

EXPlora. Introduction Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant

More information

TNC Connectors. RF Coax Connectors. Product Facts

TNC Connectors. RF Coax Connectors. Product Facts Product Facts Hex Crimp and Connectors 50 and 75 ohm commercial versions available Provides excellent performance at frequencies up to 7 GHz ow cost commercial type available type is smaller and lighter

More information

12G Broadcast connectors

12G Broadcast connectors 12G Broadcast connectors Delivering 12G in a single punch www.coax-connectors.com Welcome to COAX 12G BNC Plug return loss COAX Connectors Ltd is a leading UK designer, manufacturer and supplier of high

More information

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE NorthStar brand SERIES HD35R Heavy Duty Encoder Key Features Phased Array Sensor for Reliable Signal Output Rugged Design with Wide-Spaced Oversized Bearings Unbreakable Code Disc up to 5000PPR Improved

More information

C Connectors. Automatic Connector. Introduction. Contents. C Interface Options. 631/ FAX 631/

C Connectors. Automatic Connector. Introduction. Contents. C Interface Options. 631/ FAX 631/ utomatic onnector onnectors Introduction 2004 utomatic onnector. ll rights reserved. pdf 1.0.1 3-23-04 ontents Specifications........................... 2 Straight Plugs...................... 3 Right ngle

More information

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial DMP 5 Industrial Pressure Transmitter Welded, Dry Stainless Steel Sensor accuracy according to IEC 60770: 0.5 % FSO Industrial Pressure Transmitter Nominal pressure from 0... 6 bar up to 0... 600 bar Output

More information

FISCHER MINIMAX TM SERIES

FISCHER MINIMAX TM SERIES FISCHER MINIMAX TM SERIES CABLE ASSEMBLY INSTRUCTIONS WITH OPTIONAL BOOT BEND RELIEF THE RELIABLE EXPERT REQUIRED TOOLING To successfully cable the Fischer MiniMax Series tooling is required to insure

More information

Lightweight SMT Miniature Coaxial Connectors 1.4 mm Mated Height

Lightweight SMT Miniature Coaxial Connectors 1.4 mm Mated Height Lightweight SMT Miniature Coaxial Connectors 1.4 mm Mated Height N.FL Series Mated height comparison (With U.FL-LP(V) ) Features 1. Low profile Nominal mated height is 1.4 mm (Max. 1.5 mm) 2. Small size:

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

D-SUB ACCESSORIES OSSI : CONNECT TO EXCELLENCE D-SUB ACCESSORIES CATALOGUE / EDITION 04 CONNECTORS, PARTS AND EXCELLENCE SINCE 1974

D-SUB ACCESSORIES OSSI : CONNECT TO EXCELLENCE D-SUB ACCESSORIES CATALOGUE / EDITION 04 CONNECTORS, PARTS AND EXCELLENCE SINCE 1974 D-SUB ACCESSORIES OSSI : CONNECT TO EXCELLENCE D-SUB ACCESSORIES CATALOGUE / EDITION 04 CONNECTORS, PARTS AND EXCELLENCE SINCE 1974 Notes Supply and Service Ossi Connectors A/S is a leading supplier in

More information

3M Mini D Ribbon (MDR) Cable Assembly

3M Mini D Ribbon (MDR) Cable Assembly 3M Mini D Ribbon (MDR) Cable Assembly.050 Digital Camera Extension Cable 26 position 1WL26-TZ3B-XXX-03C Mates to popular 3M MDR 26 position receptacle on one end, and to another MDR 26 position cable assembly

More information

Look No Further... Materials & Finishes. Specifically made for all your: Gigabit Ethernet, HDMI, USB 2.0/3.0 Needs! onnectors

Look No Further... Materials & Finishes. Specifically made for all your: Gigabit Ethernet, HDMI, USB 2.0/3.0 Needs! onnectors 1 Look No Further... Specifically made for all your: Gigabit Ethernet, HDMI, US 2.0/3.0 Needs! Amphenol Aerospace now offers a connector series that can be used for all of your multi-media needs. This

More information

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic. DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter from 0... 00 mbar

More information

EBU Technical Recommendation R Connectors for camera cables with fibre optical transmission

EBU Technical Recommendation R Connectors for camera cables with fibre optical transmission Connectors for camera cables with fibre optical transmission EBU UER EBU Committee First Issued Revised Re-issued PMC 1999 Keywords: Cameras, digital processing, fibre optical transmission The EBU has

More information

Ultra Small Surface Mount Coaxial Connectors 1.4mm Mated Height

Ultra Small Surface Mount Coaxial Connectors 1.4mm Mated Height All non- products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website search at www.hirose-connectors.com, or contact your Hirose sales representative.

More information

MIL-C CLASS L COMPATIBILITY ORDERING INFORMATION

MIL-C CLASS L COMPATIBILITY ORDERING INFORMATION MIL-C-22992 CLASS L COMPATIBILITY ORDERING INFORMATION ORDERING INFORMATION: Connectors are supplied with removable contacts. Contacts are supplied unassembled. Also supplied are applicable accessories

More information

SMA One Piece Semi-Rigid Connectors

SMA One Piece Semi-Rigid Connectors SMA One Piece Semi-Rigid Connectors The Johnson captivated solderless contact connectors for semi-rigid cable provide a unique solution for high frequency cable assemblers. As compared to standard solder-on

More information

RAIL D-SUB BACKSHELLS

RAIL D-SUB BACKSHELLS RAIL D-SUB BACKSHELLS FOR D-SUBMINIATURE CONNECTORS D-SUB BACK SHELLS /// DATA SHEET RAIL D-SUB BACKSHELLS FOR D-SUBMINIATURE CONNECTORS TE Connectivity (TE) provide a comprehensive range of ruggedized

More information

+ Ten 47. Professional Audio Connectors

+ Ten 47. Professional Audio Connectors + Ten 47 Professional Audio Connectors Definitive solutions for your interconnection requirements Ten 47 was formed in 2001 to fill a niche in the interconnect market. It is our philosophy to offer high

More information

Interface RF Connector with Switch

Interface RF Connector with Switch NEW Interface RF Connector with Switch MS-5C Series Overview Designed for end user applications requiring redirection of the transmission. Small size, lightweight and high reliability make it ideal for

More information

MCX - 75 Ohm Connectors

MCX - 75 Ohm Connectors 133-8333-001 4 133-8333-401 4 133-8334-001 4 133-8334-401 4 133-8433-001 3 133-8433-101 3 133-8434-001 3 133-8445-001* 3 133-8445-101* 3 133-8701-201 5 133-8701-211 5 133-8701-301 6 133-8701-311 6 133-8701-401

More information

TE Connectivity DEUTSCH DJT Series MIL-DTL Series I Connectors

TE Connectivity DEUTSCH DJT Series MIL-DTL Series I Connectors Applications Features TE Connectivity DEUTSCH DJT Series MIL-DTL-38999 Series I Connectors High-performance military aircraft Commercial aircraft Communications equipment Armored personnel carriers & tanks

More information

Series SK (2.92 mm) prec. submini. connectors

Series SK (2.92 mm) prec. submini. connectors Series prec. submini. connectors Description Content HUBER+SUHNER SK connectors are precision connectors for microwave applications up to 40 GHz. They are intermateable with series SMA and PC 3.5. They

More information

LCS2 Cat. 6 RJ 45 Patch panels and units

LCS2 Cat. 6 RJ 45 Patch panels and units 87045 LIMOGES Cedex Telephone: 33 0 5 55 06 87 87 - Fax: 33 0 5 55 06 88 88 LCS2 Cat. 6 RJ 45 CONTENTS Page 1. General characteristics....1 2. Presentation...2 3. Installation...2 4. Technical characteristics...2

More information

Flexibility and Safety. BERNSTEIN safety hinge switches

Flexibility and Safety. BERNSTEIN safety hinge switches Flexibility and Safety BERNSTEIN safety hinge switches Safety solutions for automation engineering Our expertise for your safety In the field of industrial automation engineering, safety technology is

More information

EZ-MATE CONNECTORS The Complete Family of Multi-Channel Fiber Optic Connectors for Harsh Environment Deployable Systems

EZ-MATE CONNECTORS The Complete Family of Multi-Channel Fiber Optic Connectors for Harsh Environment Deployable Systems The Complete Family of Multi-Channel Fiber Optic Connectors for Harsh Environment Deployable Systems Overview The OCC EZ-MATE family of hermaphroditic style fiber optic connectors provides the most comprehensive

More information

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

bmam connectors DIVIDER PAGE

bmam connectors DIVIDER PAGE bmam connectors DIVIDER PAGE 4 bmam interface dimensions "E" "D" REF. PLANE "E" REF. PLANE "G" "C".0 REF. 60 "C" "B" "B".0 REF. 0 "F" "D" male, plug INCHES / MILLIMETERS MINIMUM MAXIMUM LTR. IN. MM. IN.

More information

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information M8 and M Sensor Connectors XS_-EU For a wide range of applications the XS_-EU family of M8 and M sensor connectors provides the high performance and features making the family the ideal choice for standard

More information

RCA PLUGS & JACKS Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2)

RCA PLUGS & JACKS Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2) RCA PLUGS & JACKS 24-100-0 Bulk 24-100-2 Pkg (2) Metal body RCA plug. Maximum cable dia. 7.5mm 24-104-0 Bulk 24-104-2 Pkg (2) Metal plug with strain relief. Maximum cable dia. 4.5mm Use 84-156-1 tool for

More information

Coaxial Cable Termination

Coaxial Cable Termination Coaxial Cable Termination RF one-step BNC/TNC connectors Applications RF one-step BNC/TNC connectors are single-piece assemblies for terminating the center conductor and the braid of a broad range of coaxial

More information

SMA - 50 Ohm Connectors

SMA - 50 Ohm Connectors Alphabetical Index 142-0593-001 6 142-0593-006 6 142-0593-401 6 142-0593-406 6 142-0594-001 6 142-0594-006 6 142-0594-401 6 142-0594-406 6 142-0693-001 4 142-0693-006 4 142-0693-051 5 142-0693-056 5 142-0693-101

More information

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor BI1.5-EG08K-Y1 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Sentronic PLUS Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Installation Manual Sentronic PLUS ASCO NUMATICS Sentronic PLUS Electronic Pressure Regulator Electrical Characteristics * Max. ripple: 10 % Specifications

More information

TWINTEC B Signal Circular Connectors

TWINTEC B Signal Circular Connectors Signal Circular Connectors 67 Ordering information signal circular connectors ll standard connectors are published in this catalog. However, this catalog does not provide customer specific designs or

More information

HDMI Standard Digital Interface Connector. DC1 Series

HDMI Standard Digital Interface Connector. DC1 Series COMPONENTS PRODUCT INFORMATION NEW HDMI Standard Digital Interface Connector DC1 Series CONNECTOR MB-0121-2 August 2008 RoHS Compliant Recently, the market for digital consumer devices such as LCD TVs,

More information

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1

More information

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA Hinges with built-in safety multiple switch SUPER ECHNO POLYMER IP RoHS PA +0-0 MAERIAL Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black or grey colour RAL 00 (C). Rotation pin: glass-fibre

More information

Subminiature Coaxial Switch 1.35 mm High, DC to 11 GHz

Subminiature Coaxial Switch 1.35 mm High, DC to 11 GHz NEW Subminiature Coaxial Switch 1.35 mm High, DC to 11 Hz MS-156C Series Halogen Free Overview Developed for inspection of high frequency circuits used in portable terminals.verification of the circuit

More information

Speed sensor MiniCoder GEL 2471

Speed sensor MiniCoder GEL 2471 Speed sensor MiniCoder GEL 2471 for electrically conducting toothed-wheels Technical information version 10.02 The MiniCoder family from Lenord + Bauer offers spacesaving solutions for the contactless

More information

FINE PITCH BOARD-TO-BOARD CONNECTOR SERIES THE SMART WAY TO GO FOR RELIABILITY

FINE PITCH BOARD-TO-BOARD CONNECTOR SERIES THE SMART WAY TO GO FOR RELIABILITY QUICK REFERENCE GUIDE FINE PITCH BOARD-TO-BOARD CONNECTOR SERIES THE SMART WAY TO GO FOR RELIABILITY FINE PITCH BOARD-TO-BOARD CONNECTOR SERIES When it comes to high-reliability in small spaces, TE delivers

More information

SERIES HPQN CONNECTORS

SERIES HPQN CONNECTORS SERIES HPQN CONNECTORS 1 DESCRIPTION Patented in 2008 by Anoison Electronics, the HPQN is a quick locking version of the widely used type N connector. By replacing the threaded interface of the original

More information

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features: HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement

More information

HighBand 25. TrueNet Category 6 Solutions

HighBand 25. TrueNet Category 6 Solutions HighBand 25 TrueNet Category 6 Solutions The highest performing cross-connect system in the world. A unique high-density solution with superior cable management. ADC KRONE s HighBand 25 cross connect solution

More information

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations Terminal Boxes XWD CSM_XWD_DS_E Simple Wiring of Sensor Actuators Greatly reduce wiring in combination with the Smartclick XS. Insert the connector and turn / of a turn to lock the connectors. Higher rated

More information

Catalog. Industrial Plugs & Sockets The complete range

Catalog. Industrial Plugs & Sockets The complete range Catalog Industrial Plugs & Sockets The complete range Contents Type Page Introduction... 4 IEC 60309-2 (clock)... 5 Product overview Critical & Safe... 6 Tough & Safe... 7 Easy & Safe... 8 Plugs Splashproof...

More information

Interface Connectors for Miniature, Portable Terminal Devices

Interface Connectors for Miniature, Portable Terminal Devices NEW Interface Connectors for Miniature, Portable Terminal Devices ST Series Strong locking mechanism Right Mating direction Left Top 9N max. Overview Developed as external input/output connectors for the

More information

Sensor technologies Proximity sensors Series ST4. Brochure

Sensor technologies Proximity sensors Series ST4. Brochure Series ST Brochure 2 Series ST ST Sensor, Series ST with cable open cable ends, -pin Sensor, Series ST mm C-slot with cable Plug, M8, -pin 6 Sensor, Series ST mm C-slot with cable Plug, M8, -pin, with

More information

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES FOR 75 OHM AND 75 OHM HD COAXIAL CONTACTS AND MODULES Table of Contents SECTION 1 RECEIVER CONTACT ASSEMBLY INSTRUCTIONS SECTION 2 ITA CONTACT

More information

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual Sentronic PLUS Electronic Pressure Regulator Electronic Pressure Regulator Sentronic PLUS Sentronic PLUS Electronic Pressure Regulator General Electrical Characteristics Nominal Diameter DN (mm) Voltage

More information

eclipse HYBRID POWER & SIGNAL THE SCIENCE OF CERTAINTY M06U-NC For use in power supplies, server equipment and related hardware

eclipse HYBRID POWER & SIGNAL THE SCIENCE OF CERTAINTY M06U-NC For use in power supplies, server equipment and related hardware eclipse HYBRID POWER & SIGNAL For use in power supplies, server equipment and related hardware Machined power contacts paired with formed signals offer very high performance-to-cost ratio M06U-NC Eclipse

More information

TE Connectivity DEUTSCH ACT Series MIL-DTL Series III Composite Connectors

TE Connectivity DEUTSCH ACT Series MIL-DTL Series III Composite Connectors TE Connectivity DEUTSCH ACT Series MIL-DTL-38999 Series III Composite Connectors APPLICATIONS FEATURES High-performance military aircraft Commercial aircraft Communications equipment Armored personnel

More information

Cables, Flanges, Quick Locks, Spring-loaded Cables

Cables, Flanges, Quick Locks, Spring-loaded Cables Cables, Flanges, Quick Locks, Spring-loaded Cables Industrial X-Ray Overview Technology with Passion 2 Cables, Flanges, Quick Locks Technical Data Cables L3/75 U3/100 Rated voltage 75 kvdc 100 kvdc Nominal

More information

www.mete-enerji.com.tr INDUSTIAL IEC PLUGS AND SOCKETS INDUSTIAL IEC PLUGS AND SOCKETS Position of the Earthing Contact acc. to IEC 60309-2 225/400-265/460 V~ 60 Hz (1) 3 P+N+ 3 P+ 2 P+ 120/208-144/250V~

More information

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS DATA SHEET MS 3780 INDEX OVERALL FEATURES 2 STANDARD FEATURES 2 OPTIONAL FEATURES 2 TECHNICAL DATA 2 OVERALL DIMENSIONS 3 LAYOUT 4 INSTALLATION 5 INSTALLATION RECOMMENDATIONS 6 SENSOR GROUNDING 7 SENSOR

More information

-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.

-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0. Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.6 N LE 3 NEBV Connecting cables for valves Connection technology on left, field device side B2 Socket type B to industry standard,

More information

Revision 2.0 Parts List Minor

Revision 2.0 Parts List Minor Revision.0 www.grindex.com Parts List 803.8 Minor Table of Contents Table of Contents Introduction... Specially approved products... Product Description...3 Products included... 3 The data plate...3 Exploded

More information

Broadcast Interconnect Solutions CONNECTING INNOVATION TO APPLICATION

Broadcast Interconnect Solutions CONNECTING INNOVATION TO APPLICATION Broadcast Interconnect Solutions CONNECTING INNOVATION TO APPLICATION Contact Information NORTH AMERICA United States Winchester Electronics World Headquarters 62 Barnes Industrial Road North Wallingford,

More information

Photoelectrics Through-beam Type PA18C.T..., DC

Photoelectrics Through-beam Type PA18C.T..., DC Photoelectrics Through-beam Type, DC Miniature sensor range Range: 20 m (Axial), 16 m (Radial) Sensitivity adjustment by potentiometer Modulated, infrared light 850 nm Supply voltage: to 30 VDC Output:

More information

Rectangular, Multiple-Position Rack/Panel Insulation Displacement Connectors (IDC)

Rectangular, Multiple-Position Rack/Panel Insulation Displacement Connectors (IDC) Rectangular, Multiple-Position Rack/Panel Insulation Displacement Connectors (IDC) QR/P18 Series Overview The QR/P18 Series of miniature rack/panel connectors is designed for the complete segmentation