1 Page: DPR-17 DPR100 C/D Pen and Multichannel Recorder: Digital Display Model Selection Guide with Price Data Model Selection Guide 43-DR Issue 19 (Ref. 43-DR-16-12) Instructions Select the desired Key Number. The arrow to the right marks the selections available. Make one selection each from Tables I through VII. A complete Model Number must have the designated number of digits in each table. Key Numbers I II III IV V VI VII _ - - _ - _ - VIII IX _ - KEY NUMBER (Note 1) Selection Availability Description 1 Pen Recorder DP101 2 Pen Recorder DP102 3 Pen Recorder DP103 3 Channel Recorder DM103 6 Channel Recorder DM106 TABLE I - MATH FUNCTION (Note 2) Standard - Channel Difference, Square Root 0 Math Package 1: Add, Multiply, Divide 1 Math Package 2: Pack. 1 + Fo., Group Average, Totalizer, 2 Gas/Liquid Mass Flow Math Package 3: Pack. 2 + Integ., Group Max, Min, 3 Max-Min, Steam Flow Totalization, Energy Consumption Math Package 4: Pack. 3 + RH, 10 X, Envelope, Timers, 4 Carbon Potential TABLE II - VOLTAGE (Note 3) 100 to 240 Vac/dc 50 Hz Chart speed mm/hr A 100 to 240 Vac/dc 60 Hz Chart speed inch/hr B 24 Volt ac/dc 50 Hz Chart speed mm/hr E 24 Volt ac/dc 60 Hz Chart speed inch/hr F 48 Volt ac/dc 50 Hz Chart speed mm/hr G 48 Volt ac/dc 60 Hz Chart speed inch/hr H List Price equals the sum of all prices for all selections made. Industrial Measurement and Control, 1100 Virginia Drive, Fort Washington, Pennsylvania Printed in U.S.A. Copyright 2004 Honeywell
2 Page: DPR-18 Availability D D D D D P P P M M TABLE III- OUTPUTS Selection _ Universal Communication Option 1 _ RS422/485 Modbus RTU, RS422/485 ASCII, RS232/V24 ASCII (Modem) ma Auxiliary Outputs 2 _ ma Auxiliary Outputs plus Universal 3 _ e e e e e Communications Option Alarm Relays: _ 0 6 Alarm Output _ A 12 Alarm Output _ B f f f f f 2 Alarm Output _ C TABLE IV - LOGIC INPUTS 0 2 Remote Contacts A 4 Remote Contact B TABLE V - CHART CASSETTE Fan Fold Z g g g g g Roll R TABLE VI - DOOR AND CASE Dark Gray Door, Plastic Window with Latch 1 Dark Gray Door, Plastic Window, Key Lock 2 Portable Case (Note 4) 5 Protective Case (Note 7) 6 TABLE VII - OPTIONS 0 Power Supply for Transmitter 24 Vdc (50 ma max) B _ 0 _ Rear Terminal Cover (Note 5) _ G _ 0 UL/CSA Approved C c c c c c _ 0 _ Additional 3 Inputs for Math Use _ A _ 0 Certificate of Conformance B Certificate of Calibration (Note 8) C Certificate of Conformance & User Actuation (Note 6) D Certificate of Cal + Config & User Actuation (Note 6 & 8) E User Actuation Configuration (Note 6) K Configuration to customer requirement (Note 8) L
3 Section 3 Page: DPR-19 Availability D D D D D P P P M M TABLE VIII - SPECIALS Selection ST Number (Consult Fort Washington) X X X TABLE IX - Manuals Product Information on CD English Operator Manual and Prompts 0 _ E _ French Operator Manual and Prompts F _ German Operator Manual and Prompts G _ Italian Operator Manual and Prompts I _ Spanish Operator Manual and Prompts S _ Swedish Operator Manual and Prompts W 0 English Product Manual _ 1 French Product Manual _ 3 German Product Manual _ 4 Note 1: The units are built with universal input and are delivered with 250 ohm resistors to convert input current signal 4 to 20 ma into 1 to 5 Volt dc (or 0 to 5 Vdc). These are packed in the product accessories. Note 2: Models DP1XX Pen units supplied with 3 analog inputs when Math Option is ordered. Additional 3 inputs can be selected by specifying Table VII, Option XXXAX. Note 3: The chart speed and frequency can be modified on the unit from key pad. Note 4: Portable case supplied with dark gray door, plastic window, latch, rear main switch and IEC main plug connector. Note 5: Rear cover is used to cover field wiring, this is in addition to the cover on the power supply terminals which is standard. Note 6: User defined actuation worksheets need to be completed and supplied with the order. Note 7: Supplied with metal sleeve, used on portable case option, no rear main switch or IEC main power plug connector supplied. Note 8: Customer must supply Input Actuation Type and Range for each input in the Free Form section of the order for the factory to supply the Custom Calibration Test Report (F3399). RESTRICTIONS Restriction Letter Available Only With Not Available With Table Selection Table Selection c VI 5, 6 e III _ A, _ B, _ C f III 1 _, 2 _, 3 _ g 50 o C Maximum temperature limit
4 Page: DPR-20 RECORDING SUPPLIES Description - (See Note C) Analog & Digital Display Accessories Specify Ink cartridge pen Ink cartridge pen Ink cartridge pen Ink wheel 6 colors Chart roll: 40 divisions divisions divisions divisions divisions divisions divisions Fan fold: 40 divisions divisions divisions divisions divisions divisions divisions OTHER SUPPORT Interface PC kit for product configuration (cables and software diskette included) Note (a) Application Software for ASCII Communication and PC Configurator Wiring bracket with cable clamp Plastic rule graduated Note (b) item 6 input resistors (250 ohms) for ma inputs Scale (b) DPR 100 A/B Multichannel models item 1, 2, 3 pen models item Blank scale (for pen recorder) DPR 100 A New scale establishment DPR 100 A/B Contact Product List Price = $175 US Cable between PC Configurator and PC Management Cable between PC Configurator and Recorder Configuration Card (Programming aid) CCPLEN-6137 Communication Cable (DB25 male to DB9 female RS232) Adapter Plate CL 111 to DPR Adapter Cable DPR 100 to TDC OPERATOR MANUALS DPR 100 C/D U.S. Manual French Manual German Manual Italian Manual Spanish Manual Swedish Manual OPERATOR MANUALS DPR 100 A/B English Manual French Manual German Manual Italian Manual Dutch Manual Spanish Manual Swedish Manual US1I-6136 FR1I-6136 GE1I-6136 IT1I-6136 SP1I-6136 SW1I-6136 US1I-6125 FR1I-6125 GE1I-6125 IT1I-6125 NL1I-6125 SP1I-6125 SW1I-6125 Accessories continued next page
5 Section 3 Page: DPR-21 PRODUCT MANUALS DPR 100 English Manual DPR 100 A/B U.S. Manual DPR 100 C/D Math Manual DPR 100 C/D Communication Manual DPR 100 C/D US1I-6126 US1I-6137 US1I-6138 US1I-6149 Note (a): Note (b): Note (c): The product manual contains calibration and PC configuration information. To specify the range, refer to Range Scale Bulletin for DPR 100 A/B Recorder. Specification Sheet: 0I-6030 DPR 100 A/B: 0I-6021 DPR 100 C/D Sales Brief: 43-DR Consult Honeywell Order Entry Systems for current parts pricing.
6 Page: DPR-22 USER DEFINED ACTUATION DPR100C/D Fax to York Customer Service CUSTOMER ORDER No SALES ORDER No. TYPE OF ACTUATION - T/C LINEAR (mv) Ma V RTD (Check one) If thermocouple - complete table for Recorder Operating Temperature for Cold Junction Compensation Actuation Cold Junc. Eng. Unit Electrical Actuation Cold Junc. Eng. Unit Electrical 1 Value Deg. C Value (mv) 2 Value Deg. C Value (mv) Lowest Lowest Average Average Highest Highest USER DEFINED ACTUATION TABLE 1 Enter values for custom actuation (max 50 SEGMENTS) Segment ENG Electrical Segment ENG Electrical Segment ENG Electrical Number VALUE VALUE Number VALUE VALUE Number VALUE VALUE USER DEFINED ACTUATION TABLE 2 Enter values for custom actuation (max 50 SEGMENTS) Segment ENG Electrical Segment ENG Electrical Segment ENG Electrical Number VALUE VALUE Number VALUE VALUE Number VALUE VALUE
Pen and Multichannel Recorder: Digital Display
Issue 10 Page 1 of 6 DPR100 C/D Model Selection Guide Pen and Multichannel Recorder: Digital Display Instructions Select the desired Key Number. The arrow to the right marks the selections available. Make
More informationUDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4
UDC100 Universal Digital Controller 51-52-03-29 11/99 Page 1 of 4 Specification Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process, Strain & Potentiometer Follower Signals Features Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges Selectable ±2, ±20, ±200
More informationSection C Recorders. DPR mm Digital Strip Chart Recorder
91-00-01-01 Section C Recorders Contents Product Type Literature No. Overview 40-00-02-02 LeaderLine PC Software 51-52-03-16 SCF Software Configuration Tool 51-52-03-26 SDA Software Data Analysis Tool
More informationLAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description
Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999
More informationVorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)
Vorne Industries 87/719 Analog Input Module User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Introduction... 1.1 Accessing Wiring Connections
More informationUNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load
More informationWall-/Pipe-Mount Level Indicator
Data Sheet SS/_4 Wall-/Pipe-Mount Level Indicator High visibility 5-digit LED display clear multi-functional indication Analog and 2-relay outputs as standard high, low, latch and rate alarms, plus isolated
More informationR1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)
INSTRUCTION MANUAL THERMOCOUPLE & INPUT MODULE (8 points; isolated) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationHybrid Chart Recorder 250 mm (10")
Hybrid Chart Recorder 250 mm (10") RD5100 Series U High Speed Scanning at 36 Points/Sec and High-Speed Recording U High Accuracy of 0.05% U Various Industrial Values Can be Measured at the Same Time with
More informationProcess Transmitter RMA 422
Technical Information TI 072R/24/ae Process Transmitter RMA 422 Multi-functional 1-2 channel top hat DIN rail unit with loop power supply, alarm set point monitoring, mathematics function and 1-2 analog
More informationAE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT
FN: 341MAN1.DOC AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT DESCRIPTION AE Series Process Indicators are available with 1", 2.3", 4", 8", or 12" high digits,
More informationPanel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features
NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description
More informationCARLO GAVAZZI Automation Components
CARLO GAVAZZI Automation Components UDM 35/40 Digital Panel Meter Programming Guide Index Description 2 Programming Fundamentals 3 Access to Programming Mode/Password Protection 4 Programming 5-18 Inputs
More informationDCP100 Digital Control Programmer Specifications
DCP100 Digital Control Programmer Specifications EN01-6028 October 1996 Overview The DCP100 is a microprocessor based 1 /4 DIN programmer/controller for process variable versus time control of temperature,
More informationSCALE & WEIGHT DISPLAYS
The MICRO SERIES SCALE & WEIGHT DISPLAYS LARGE DIGIT MODELS Mighty-5S DPM MODELS Micro-S & Mighty-1S Mighty-1S Micro-S ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters
More informationInstruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control
Series 3000 Model R-165A Audio/Video IF/RF Relay Panel Instruction Manual CATV Switching and Control 585-765-2254 fax 585-765-9330 100 Housel Ave. Lyndonville NY 14098 www.monroe-electronics.com Table
More informationProcess transmitter RMA422
Technical information TI072R/09/en Mat. No. 51001905 Process transmitter RMA422 Multifunctional 1-2 channel top hat DIN rail unit with intrinsically safe current input and loop power supply, alarm set
More informationManual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.
Manual Title: 744 Users Supplement Issue: 6 Part Number: 691287 Issue Date: 4/06 Print Date: September 1998 Page Count: 8 Revision/Date: 1, 2/99 This supplement contains information necessary to ensure
More informationOPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016
OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016 1-800-TIP-TEMP Tel. (609) 239-1900 Fax (609) 239-1911 www.tiptemp.com GENERAL
More informationSTBART0200K standard analog input kit STB - 2 I - 15 bits + sign
Product data sheet Characteristics STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Main Range of product Product or component type Kit composition Analogue input type Analogue input number
More informationTELEDYNE HASTINGS INSTRUMENTS
DVT (Digital VT) DCVT (Digital CVT) www.teledyne-hi.com TELEDYNE HASTINGS INSTRUMENTS Vacuum Measurement RANGES DV-4 (0.1 20 Torr) DV-5 (0.1 100 mtorr) DV-6 (1 999 mtorr) FEATURES Linear Analog Output
More informationStandard RS232 RS ma
1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision
More informationTempScan/1100 & MultiScan/1200
High-Speed Temperature & Voltage Scanning Instruments Measures thermocouples, volts, and RTDs at up to 960 channels/s Accepts optional scanning modules for measuring thermocouples, RTDs, or DC volts Expandable
More informationGlobal Water Instrumentation, Inc.
Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 PRODUCT NAME: 378 TEMPERATURE CONTROLLER - 1 - The model 378 is a high performance
More informationManual. Simrad IS80 Heading Repeater HR80. English
Manual Simrad IS80 Heading Repeater HR80 English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Manual Simrad IS80 Heading Repeater HR80 English Document no: 20223194 Revision:
More informationSet Point Controller OC557. Operator s Manual
OC557_Manual_GB1206D Set Point Controller OC557 4 20mA Input Operator s Manual METRIX ELECTRONICS LTD. Tel: +44 (0)845 034 3234 Minchens Court, Minchens Lane Fax: +44 (0)845 034 3233 Bramley, Tadley, Hampshire
More informationSQM40/41 Actuators for air and gas dampers
SQM40/41 Actuators for air and gas dampers Description SQM40/41 actuators are used for the positioning of flow control valves, butterfly valves, dampers or any application requiring rotary motion. The
More informationFTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process
FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]
More informationIMPAC Infrared Thermometers
IMPAC Infrared Thermometers focusable optics for non-contact temperature measurements on metals, ceramics, graphite etc. between 300 and 3300 C IS 140 IGA 140 IS 140-PB IGA 140-PB Short response times
More informationModel 5250 Five Channel Digital to Analog Video Converter Data Pack
Model 5250 Five Channel Digital to Analog Video Converter Data Pack E NSEMBLE D E S I G N S Revision 3.1 SW v2.0.1 This data pack provides detailed installation, configuration and operation information
More informationactions. 12 digital outputs can be assigned to 4 different types of events (MODE, Alarm, Time and PV) 32 Programs, 800 segments
05/06 30-08-10-05-EN Page 1 of 14 IPC5000 S/D Universal Programmer Specification Overview The IPC5000 is a high-functional Single or Dual loop programmer retaining all the reliability, simplicity, and
More informationChromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display
Technical Information Paper recorder Mulit-channel strip chart recorder with digital measured value display Application The device is an intelligent data recorder with a recording width of 4" (100 mm).
More informationOcean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff
Ocean Sensor Systems, Inc. Wave Staff III, OSSI-010-008 With 0-5V & RS232 Output and A Self Grounding Coaxial Staff General Description The OSSI-010-008 Wave Staff III is a water level sensor that combines
More informationFTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process
FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]
More informationMicro-DCI 53ML5100 Manual Loader
Micro-DCI 53ML5100 Manual Loader Two process variable inputs Two manually controlled current outputs Multiple Display Formats: Dual Channel Manual Loader, Single Channel Manual Loader, Manual Loader with
More informationDATA SHEET Panorama Rudder Indicator, TRI-2
DATA SHEET Panorama Rudder Indicator, TRI-2 Class 1 accuracy on CAN version Readable from up to 5 metres Single and dual CAN or analogue interface LED illumination DEIF A/S Frisenborgvej 33 DK-7800 Skive
More informationModel 6010 Four Channel 20-Bit Audio ADC Data Pack
Model 6010 Four Channel 20-Bit Audio ADC Data Pack Revision 3.1 SW v1.0.0 This data pack provides detailed installation, configuration and operation information for the Model 6010 Four Channel 20-bit Audio
More information5700 series Displays PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY
5700 series Displays PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY Efficiency in focus The process industry puts a constant focus on efficiency
More informationAES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter
Broadcast Devices, Inc. AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide Web:
More informationSignal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters
Signal Conditioners Highlights Battery powered Line powered Multi-purpose Modular-style Multi-channel Charge & impedance converters Industrial charge amplifiers & sensor simulators PCB Piezotronics, Inc.
More informationALLEN BRADLEY TIMING RELAY
ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY
More informationREMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual
REMOTE I/O R30 SERIES PC CONFIGURATOR SOFTWARE Model: R30CFG Ver. 1.13 Users Manual 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 http://www.m-system.co.jp/
More informationOmega.com TM. DPS3100 & DPS3200 series Programmable Scanners
Omega.com TM http://www.omega.com e-mail: info@omega.com DPS3100 & DPS3200 series Programmable Scanners TABLE OF CONTENTS SPECIFICATIONS... 3 DESCRIPTION... 4 DISPLAYING PARAMETERS... 5 Table 1. How to
More informationManual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12
R60722.0002 - Index 3 Analog (U/I) Manual Absolute multiturn encoder Order code: 8.M36X1.XXXX.XX12 Order code: 8.M3661R.XXXX.XX12 Order code: 8.M5861.XXXX.XX12 Publisher Kübler Group, Fritz Kübler GmbH
More informationG.R.A.S. Sound & Vibration
Instruction Manual Single-channel Low-noise Measuring System consisting of: ½-inch Low-noise Level Microphone System Type 40HH and Power Module Type 12HF 40HH 12HF G.R.A.S. Sound & Vibration Skovlytoften
More informationMagnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A
and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature
More informationHN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/
Connectors Introduction 2004 Automatic Connector. All rights reserved. pdf 1.0 4-13-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable
More informationOcean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff
Ocean Sensor Systems, Inc. Wave Staff, OSSI-010-002F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff General Description The OSSI-010-002E Wave Staff is a water level sensor that
More informationModel 5405 Dual Analog Sync Generator Data Pack
Model 5405 Dual Analog Sync Generator Data Pack E NSEMBLE D E S I G N S Revision 2.1 SW v2.0 This data pack provides detailed installation, configuration and operation information for the 5405 Dual Analog
More informationORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual
ORM0022 EHPC210 Universal Controller Operation Manual Revision 1 EHPC210 Universal Controller Operation Manual Associated Documentation... 4 Electrical Interface... 4 Power Supply... 4 Solenoid Outputs...
More informationInductive sensor. 2-wire, analog output BI8-M18-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M18 x 1 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring diagram Type code Ident no.
More informationManual. Simrad IS80 Wind Instrument WI80. English
Manual Simrad IS80 Wind Instrument WI80 English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Manual Simrad IS80 Wind Instrument WI80 English Document no: 20223202 Revision:
More informationArt M Digital codelock module
CODELOCK UNIT MODULES Art. 4900-4900M This module has on the front a 12 stainless steel button keypad (keys from 0 to 9 plus ENTER and CLEAR keys), 2 LEDS for operation signalling, the keypad illumination
More informationInductive sensor With analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection Wiring Diagram Type designation
More informationMBUS 10 RS232 TO MBUS LEVEL CONVERTER
Media and protocol converters MBUS 10 RS232 TO MBUS LEVEL CONVERTER RS232 to MBus level conversion Maximum 10 MBus slaves Baud Rate: 300 to 19200 bps RS232 MBus opto isolation Over-current and short-circuit
More informationBL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC
Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 2 analog
More informationSAL Series Wireless Clock (V1)
SAL Series Wireless Clock (V1) HIGHLIGHTS Microprocessor based movement Each clock acts as a repeater and transmitter 915 928MHz frequency hopping technology Receiving and transmission rate every four
More informationCONTRACTORS SPECIFICATION
VICON PRODUCT SPECIFICATION NOTES SPEC NO. REV. SEC. SUPERSEDES PRODUCT SPECIFICATION 735-594 735 1299 10 MODEL: V1902VCT PRODUCT CODES: REFER TO TABLE 1 DESCRIPTION: VICOAX TRANSMITTER FOR A COAXIAL CONTROL
More informationUNIGAS Hand-held combustion gas analyzer with 3 sensors
UNIGAS 2000 Hand-held combustion gas analyzer with 3 sensors Unigas 2000+ is a professional flue gas analyser for 3 gases: O 2, CO & NO with electrochemical sensors, plus CO 2 and NO x calculated. Description
More informationKey Features and Functions. General Description
AU301-DP Product Name GR03490 Manufacturer's Part Number Technical Specification Summary Frequency Range 470-862MHz Typ. Gain 56 db P1dB 1900 W Typ. Efficiency > 40% At 1dBcp Analogue TV 1400 Wps Temperature
More informationModel IQ4-PC User Manual Revision Date:
Basic Specifications Supply Volts 230V 50/60Hz ±15% 115V 50/60Hz ±15% 24V DC (isolated) ±15% Power Consumption Max. 3VA (IQ4-PC-R0) Max. 6VA (IQ4-PC-R2-PSI24-RT) Operating Temperature -5 ~ +60 C Operating
More informationDMP 331i / DMP 333i LMP 331 i
DMP i / DMP i LMP i Precision Pressure Transmitter / Screwin transmitter Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO from 0... 00 mbar up to 0... 600 bar Output signal wire:... 0 ma
More informationRK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics
RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output
More informationPCR AUTOMATIC HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More information02/11/2015
24 x 48 Totalizers CTR24 non-backlit model Part number 87622062 Display : 8-digit LCD, height 8 mm Powered by a lithium battery Counter inputs : solid state (4-30 VDC) or voltage (10 260 VAC) Reset on
More informationAMU2-2MHD+ Audio monitoring Unit
AMU2-2MHD+ Audio monitoring Unit Handbook TSL Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200, FAX +44 (0)1628 676299 AMU2-2MHD+-6 1 ISSUE 5 SAFETY Installation. Unless otherwise
More informationModel KBF 1020 Constant climate chambers with large temperature / humidity range
Model KBF 1020 Constant climate chambers with large temperature / humidity range The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate
More informationModel KBF 115 Constant climate chambers with large temperature / humidity range
Model KBF 115 Constant climate chambers with large temperature / humidity range The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate
More informationUser Guide Supplement M4 ( MHz) CONTENTS UHF WIRELESS SYSTEM
User Guide Supplement M4 (662-692 MHz) UHF WIRELESS SYSTEM CONTENTS SPECIFICATIONS... 2 FURNISHED ACCESSORIES... 5 OPTIONAL ACCESSORIES... 6 REPLACEMENT PARTS... 6 UHF WIRELESS SYSTEM COMPATIBILITY GUIDE...
More informationINSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD
1 INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD NOTE TO INSTALLERS: PLEASE RETURN THIS MANUAL TO THE INDIVIDUAL IN CHARGE OF THE SCOREBOARD UPON COMPLETION OF INSTALLATION. The scoreboard
More informationINSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras
INSTALLATION MANUAL FT-FOTR-8VD-ST-S 8-Channel Digital Duplex Baseband Transmitter and Receiver With Reverse Transmission for PTZ Cameras v1.0 4/5/11 1 PACKAGE CONTENTS This package contains: One each
More informationModel GS Port Node 1 GHz with 65/86 MHz split
Model GS7000 4-Port Node 1 GHz with 65/86 MHz split The Model GS7000 4-Port Node is our latest generation 1 GHz optical node platform and utilizes a completely new housing designed for optimal heat dissipation.
More informationWeekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N
Weekly Timer 1/4 DIN Size Timer Features Prompted Programming and Large LCD Display 24 hours x 7 days programming using just 5 switches 16 program steps and cycle operation Two independent 15 A control
More informationPACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB
September 2013 PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB The PACSystems * Thermocouple Input module IC695ALG412 provides twelve isolated differential thermocouple input channels.
More informationElectrical connection
Color sensors Dimensioned drawing en 02-2013/01 50121262 068-14515 12mm 32mm 10-30 V DC 500 Hz Scanner for color detection Simultaneous selection of up to 3 colors Detection independent of distance Teach-in
More informationEVENT INPUT/OUTPUT MODULE [PUME]
PUM Series Multi-loop module type Temperature controller DATA SHEET EVENT INPUT/OUTPUT MODULE [] is a digital input/output module used as an auxiliary input/output of control modules. Each module, 30mm
More informationINSTALLATION INSTRUCTIONS FOR
INSTALLATION INSTRUCTIONS FOR MODEL 2240LED www.sportablescoreboards.com 1 Table of Contents 8 X 7 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR
More informationUser s Manual. Models /436102/436103/436104/ µr10000 Recorder. IM 04P01B01-01E 3rd Edition. Yokogawa Electric Corporation
User s Manual Models 436101/436102/436103/436104/436106 µr10000 Recorder Yokogawa Electric Corporation 3rd Edition Foreword Thank you for purchasing the YOKOGAWA µr10000 Recorder. This manual describes
More informationAES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter
Broadcast Devices, Inc. AES-408 8 Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter Technical Reference Manual Broadcast Devices, Inc. Tel. (914) 737-5032 Fax. (914) 736-6916 World Wide
More information1x12 VGA & Audio over CAT5 Splitter
SP-9112 1x12 VGA & Audio over CAT5 Splitter User Manual rev: 160322 Made in Taiwan Safety and Notice The SP-9112 1x12 VGA & Audio over CAT5 Splitter has been tested for conformance to safety regulations
More informationAssembly Level Service Guide
Assembly Level Service Guide This guide describes how to service the Agilent 53150A, 53151A, and 53152A Microwave Frequency Counters. The information in this guide applies to instruments having the number
More informationElectronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650
M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.de
More informationProduct Information. EIB 700 Series External Interface Box
Product Information EIB 700 Series External Interface Box June 2013 EIB 700 Series The EIB 700 units are external interface boxes for precise position measurement. They are ideal for inspection stations
More informationINSTALLATION INSTRUCTIONS FOR. MODEL 2230LED
INSTALLATION INSTRUCTIONS FOR MODEL 2230LED www.sportablescoreboards.com 1 Table of Contents MODEL 2230LED... 3 8 X 4 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:...
More informationControlMaster CM15 Universal process indicator 1 /8 DIN
User Guide IM/CM/I EN Rev. I ControlMaster CM15 The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and
More informationLARGE DIGITAL TEMPERATURE LED DISPLAYS
LARGE DIGITAL TEMPERATURE LED DISPLAYS THERMOCOUPLE & PT100 (RTD) INPUTS Alarms and Retransmission Output 0-10Vdc, 4-20mA, RS-232, RS-485, Modbus, ASCII INDOOR OR OUTDOOR USE 3, 4, 5, Digits with Decimal
More informationFor applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.
For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted. N223 Reliance Electric s MD60 AC Drive is ready to operate out-of-the-box!
More informationED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features
Description Page 1 of 13 The ED3 is an LCD readout that serves as a position indicator or tachometer. The ED3 can display: Speed or position of a quadrature output incremental encoder Absolute position
More informationV1602 / V1602CP. ANALOGUE VIDEO ROUTER - 16x2. Rev. 6
V1602 / V1602CP ANALOGUE VIDEO ROUTER - 16x2 Rev. 6 June 10, 2004 Network Electronics ASA Thorøya P.O. Box 1020 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47 33 48 99 98 e-mail: support@network-electronics.com
More informationSPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel
1993 Specifications CSJ 0924-06-223 SPECIAL SPECIFICATION 1160 8:1 Video (De) Mux with Data Channel 1. Description. This Item shall govern for furnishing and installing an 8 channel digital multiplexed
More informationElectronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,
Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency, Temperature, RPM, Pressure, etc. LED/ LCD displays 1999 to 99999
More informationModel 5240 Digital to Analog Key Converter Data Pack
Model 5240 Digital to Analog Key Converter Data Pack E NSEMBLE D E S I G N S Revision 2.1 SW v2.0 This data pack provides detailed installation, configuration and operation information for the 5240 Digital
More informationSV180 VideoGraphic Recorder and Data Acquisition System
SV180 VideoGraphic Recorder and Data Acquisition System USER MANUAL Document issue: MO100202-01.0 01/2002 SERIAL NO. TAG NO. Manual Part Number MO100202-01 Thermo Westronics 22001 North Park Dr. P Suite
More informationModel KBF P 240 Humidity test chambers with ICH-compliant light source
Model KBF P 240 Humidity test chambers with ICH-compliant light source The KBF P humidity test chamber, equipped with ICH-compliant light source, is an expert when it comes to photostability tests and
More informationGuide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area
Guide for installers METTLER TOLEDO MultiRange System solution analog Ex1 Hazardous area Safe area System solution analog Ex1 Contents Contents Page 1 Safety precautions... 2 2 System overview... 3 2.1
More informationMULTIBAND 1/3 RACK-MOUNTED
BLOCK CONVERTER FEATURES Cover multiple ITU Ku-Band regions and other combinations Automatic 5/10 MHz internal/external reference selection with a 0.1 Hz nominal bandwidth clean-up loop RS-485/RS-422 and
More information2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES
EN K20RTD 2 WIRE - LOOP POWERED TRANSMITTER FOR PT00 AND NI00 PROBES General Description The K20RTD instrument converts a temperature signal read by a PT00 (EN 60 75) or NI00 probe with connection by 2,
More informationModel KT 53 Cooling incubators with thermoelectric cooling
Model KT 53 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the
More informationSIREC P, PA, L, LA. Manual
SIREC P, PA, L, LA Multipoint recorder P 7ND 3021-xB... Multipoint recorder PA 7ND 3021-xA... Line recorder L 7ND 3121 Line recorder LA 7ND 3125 Manual Line recorder Multipoint recorder The reproduction,