2 Table of Contents/Quality and eliability Quality and eliability 1 () Lighting Distribution Cable 2 () eddy-connect Cable D Series 3 (LC) Lighting Cable 4 (D) eddy-connect Distribution Cable 5 (LS) Lighting Switch Unit 6 (LA) Lighting Adapter Type 7 7 (LJ) Lighting Junction Circuit Splitter 8 (LT) Lighting Tap 9 Typical Layout Drawing 10 Switching Diagram 11 Switching Diagram/Advantages 12 Typical 3-ay/4-ay Switching Layout 13 Voltage Drop Guide and lectrical Code 14 Quality Design Features ated for 20 Amps, 600 Volts UL listed Five wire B labeled Keyed to prevent voltage mismating ositive spring steel latches Suitable for use in air handling spaces other than ducts and plenums Terminals are tin plated copper high performance alloy nstallation of all lectro/connect parts made easy by the male-to-female configuration Connector bodies are UL V-0 94 rated Labels color coded by voltage #12 AG THH conductors Approved for make or break underload eliable Construction Simple Four basic components re-wired Flexible asily maintained components Simple installation Quick Labor saving asy material estimating Components snap and lock togetherno tools required educes costs asy fixture relocation conomical Leased spaces occupied quickly All components reusable Changes made with minimal disruption 1 eliable Metal encased Fully grounded ational assistance network
3 Lighting Distribution Cable Lighting Distribution Cable The () Lighting Distribution Cable is the starting point of the wiring system. Features re-wired with female (power out) connector, opposite end has 6" leads and 1/2" knock-out connector for mounting to a junction box. nternal wires are #12 AG THH stranded copper, 600V, plus a bare #12 AG solid copper ground conductor. Maximum 5 conductors in the cable. Cable head is 18 gauge steel, zinc plated. ne, two or three circuit cable sets are available. anelboard controlled Local Switching LC LS SAML CATALG UMB: DSGAT Lighting Distribution Cable G CFGUAT 1 1 circuit 2 2 circuit 3 3 circuit 2 circuit, 2 neutral VLTAG v v v LGTH Blank 3 inches 09 9' 15 15' 2
4 eddy-connect Cable D Series eddy-connect D Series The () eddy-connect D Series Cable provides a feed-thru power from fixture to fixture. n addition, the D Series Cable provides a power tap to the lighting fixture by snapping into the access plate or 1/2" knock-out. t is quickly and easily field installed by inserting ballast leads into poke home connectors. o wire nuts required. Features #12 AG THH stranded copper, 600V. Fixture taps are #18 AG TF solid copper conductors, connected to oke-home connectors. ositive Spring Steel Latches. eddy-connect D Series cables can be pre-wired to lighting fixture by fixture manufacturer. anelboard controlled Local Switching LC LS SAML CATALG UMB: -27-1D-09 DSGAT eddy Connect Cable G CFGUAT 1D 1 circuit 2D 2 circuit 3D 3 circuit D 2 circuit, 2 neutral 3 VLTAG v v v LGTH 05 5' 07 7' 09 9' 11 11' 13 13' 15 15' 17 17' 21 21' 25 25' 30 30'
5 Lighting Cable LC LC Lighting Cable The (LC) Lighting Cables distribute lighting circuits to (LS) Lighting Switch Unit, or to another (LC) Lighting Cable or () eddy- Connect Cable to extend length. Features re-wired with male (power-in), female (power-out) configuration. nternal wires are #12 AG THH stranded copper, 600V, plus a bare #12 AG solid copper ground conductor. Galvanized steel cable. Cable heads are 18 gauge steel. ne, two or three circuit capability. Spring steel latches. Local Switching LC LS SAML CATALG UMB: LC LC DSGAT LC Lighting Cable G CFGUAT 1 1 circuit 2 2 circuit 3 3 circuit 2 circuit, 2 neutral VLTAG v v v LGTH 05 05' 07 07' 09 9' 11 11' 13 13' 15 15' 17 17' 21 21' 25 25' 30 30' 4
6 eddy-connect Distribution Cable D D eddy-connect D Series This cable may be used as an alternative to feed power to the first fixture on a circuit run (to be used only when local switches are hardwired or circuit to be panelboard controlled). t replaces two components, the () Lighting Distribution Cable and the () eddy-connect Cable feeding power to the first fixture. Features #12 AG THH stranded copper, 600V. Fixture taps are #18 AG TF solid copper conductors, connected to oke-home connectors. ositive Spring Steel Latches. eddy-connect D Series cables can be pre-wired to lighting fixture by fixture manufacturer. anelboard controlled Local Hardwired Switching D D D SAML CATALG UMB: D-27-1D-09 D DSGAT D eddy-connect Distribution Cable G CFGUAT 1D 1 circuit 2D 2 circuit 3D 3 circuit D 2 circuit, 2 neutral VLTAG v v v LGTH 09 9' 15 15' 5
7 Lighting Switch Unit LS LS Lighting Switch Unit The (LS) Lighting Switch Unit provides power-in/power-out connections and switched power-out for fixtures being locally switched. The (LS) Lighting Switch Unit is located above the switch location. The (LC) Lighting Cables feed unswitched power to each (LS) Lighting Switch Unit. Features Unit is low profile, less than one inch. Die cast housing with zinc plated steel cover plate. Six inch tap leads. nternal wires are #12 AG THH solid copper with bare #12 AG solid copper ground conductor. 1/2" knock-out connector for mounting to junction box. Local Switching LC LS SAML CATALG UMB: LS-27-ML-15 LS DSGAT LS Lighting Switch Unit VLTAG v v v G CFGUAT SL Single Level ML Multi-Level (1 circuit) 2C Multi-Level (2 circuit) 3A 1st Three way 3B 2nd Three way 4 Four way LGTH 07 07' 15 15' 6
8 Lighting Adapter (Type 7) LA LA Lighting Adapter The (LA) Lighting Adapter provides a power-in/power-out connection for continuing power to the next lighting fixture, and provides a power tap to exit signs, surface mounted fixtures or other out-of-system devices. Features Adapter is 2-13/16" x 2-13/16"x 13/16" installed. Male (power-in) and female (power-out) configuration. Die cast housing with zinc plated steel cover plate. Type 7M adapter wires are #12 AG THH stranded copper conductors, 600V, six inch tap leads. Fixture adapter can be factory or field installed. 1/2" knock-outs connector for mounting to fixture. All adapters are thru-wired for three circuits with #12 AG. anelboard controlled LA (TY 7) XT SAML CATALG UMB: LA-27-7A-09 LA DSGAT LA Lighting Adapter VLTAG v v v G CFGUAT 6M* 2 circuit (A & B tap) 7M 2 circuit (A & B tap) 7A A phase tap 7B B phase tap 7C C phase tap 7T 3 circuit (A, B, & C tap) LGTH Blank 3 inches 09 09' 15 15' 20 20' *6M type adapter tap leads are #18 AG THH conductors. 7
9 Lighting Junction Circuit Splitter LJ LJ Lighting Junction Circuit Splitter The (LJ) Lighting Junction Circuit Splitter can be plugged into an (LC) Lighting Cable, () eddy-connect Cable or (LA) Lighting Adapter to divide the cable run in two directions. The phase splitters have power-in/power-out connectors for the continuation of 3-circuit power to the next fixture. Features Splitter casting is 5-5/8" x 3-1/8" x 13/16". Die cast housing with zinc plated steel cover plate. nternal wires are #12 AG THH stranded copper. Circuit splitter is thru-wired for three circuits. Local Switching LJ LT XT SAML CATALG UMB: LJ-27-3 LJ 3 DSGAT LJ Lighting Junction G CFGUAT 3 Circuit Splitter VLTAG v v* v* v v v* *Consult factory for these applications. 8
10 Lighting Tap LT LT Lighting Tap The (LT) Lighting Tap Cable is part of the flexible wiring system that provides power to all of the out-of-system devices. Features re-wired with male (power-in) connector with six inch leads at opposite end with 1/2" knock-out connector for mounting to a junction box in standard 1/2" knock out. nternal wires are #12 AG THH stranded copper, 600V, plus a bare #12 AG solid copper ground conductor. Cable head is 18 gauge steel, zinc plated. Spring steel latches are on the male (power-in) cable head. Single circuit, two circuit and three circuit cable sets are available. anelboard controlled LT XT LT SAML CATALG UMB: LT LT DSGAT LT Lighting Tap G CFGUAT 1 1 circuit 2 2 circuit 3 3 circuit 2 circuit, 2 neutral VLTAG v v v LGTH Blank 3 inches 09 09' 15 15' 20 20' 9
11 Typical Layout Drawing eddy-connect Local Switching 1,3 J D Homerun from lighting panel oom A Circuit 1 SS S oom B Circuit 1 SS Symbol D Description Lighting Distribution Cable Lighting Switch UnitSingle Level Lighting Switch UnitMulti Level Lighting Cable eddy-connect Cable eddy-connect - anelboard Controlled J Homerun from lighting panel 1 D D 3 oom A Circuit 1 oom B Circuit 3 Symbol D Description eddy-connect Distribution Cable eddy-connect Cable 10
12 Switching Diagram Single-Level Switching Single ole Switching Single ole 3-ay Switching LS-12/27-SL-XX USTCHD LS-12/27-SL-XX USTCHD STCHD STCHD BA BA UL UL TAVLS HADD BY THS ne Circuit Multi-Level Switching Double ole Switching Double ole 3-ay Switching LS-12/27-ML-XX USTCHD LS-12/27-ML-XX USTCHD STCHD STCHD BA K UL 3 AY BA a K UL a 3 AY b b TAVLS HADD BY THS 11
13 Switching Diagram/Advantages Two-Circuit Multi-Level Switching Double ole Switching Double ole 3-ay Switching LS-12/27-2C-XX USTCHD LS-12/27-2C-XX USTCHD STCHD STCHD BA BA K D UL UL D K 3 AY a a 3 AY b b TAVLS HADD BY THS Advantages All fixture types are wired alike, regardless of switching control (single-level or one circuit multilevel switching). educes fixture sorting at the job site. Standardize on one type switching unit regardless of switching control (single-level or multi-level switching). Job site simplification: when using one circuit multi-level switch unit for single-level or one circuit multi-level. LS-12/27-ML-XX USTCHD Dust Cover Must cover any unused power-out connector. asy snap-in connection. ill cover any power-out connector. May be removed by hand. STCHD BA K UL Single pole switching by using a one circuit multi-level switch unit. 12
14 Switching Diagram 3 and 4 ay Switching 3 AY 4 ay 3 ay LS-12/27-3A -XX USTCHD LS-12/27-4-XX U T LS-12/27-3B -XX UT STCHD BA K UL BA K UL K BA K UL Typical 3-ay/4-ay Switching Layout S 3 L-1 J 1 S 3 S4 D SYMBL D S3 S4 DSCT Lighting Distribution Cable 1st 3-ay Switch Unit 2nd 3-ay Switch Unit 4-ay Switch Unit eddy-connect Cable otes: hen using lectro-connect in system components for 3-way and 4-way switching, the following requirements must be met These units can only be used on fixtures wired for single level. 2.All cables between these switching units must be five wire. Switch travelers are carried through the cables. 3.Drop to first 3-way switch requires one LS-12/27-3A-XX switch unit. 4.Drop to second 3-way requires one LS-12/27-3B-XX switch unit. This switch may be placed at any point in the cable run of the area serviced by these 3-way switches. t does not have to be on the last fixture. 5.Dropping to 4-way switch requires one LS-12/27-4-XX switching unit. This may be placed at any point in the cable run of the area serviced by these 4-way switches, but must be installed between the first and second 3-way drops.
15 Voltage Drop Guide/ational lectrical Code Conditions amp branch circuit derated at 20% to 16 amps ft. fluorescent fixtures having standard lamps and ballasts. 3. Section A, 50 ft. homerun from lectro/connect distribution point to panelboard with o.12 conductors. 4. Section B, 20 ft. branch cable from distribution point to first fixture in the run. 5. Section C, branch cables connecting fixtures, in two lengths: a) 10 ft. cables for 8 ft. x 8 ft. square fixture layout b) 12 ft. cables for 8 ft. x 8 ft. staggered fixture layout CDUT & AL BAD X (T ADDTAL FXTUS) FXTU FXTU SCT A SCT B SCT C 277 VLT SYSTM o. of fixtures in run Line current, amps 10 Cable LAM 3-LAM 4-LAM 12 Cable 10 Cable 12 Cable 10 Cable VLTAG D F 277 VLTS Section A, 50 #12 Section B, 20 Cable Total A + B, volts Section C, 10 Cables Section C, 12 Cables Total A + B + C, volts Maximum Allowable Voltage Drop = 8.31 Volts (3% of Line Voltage) 120 VLT SYSTM o. of fixtures in run Line current, amps 10 Cable Section A, 50 #12 Section B, 20 Cable Total A + B, volts Section C, 10 Cables Section C, 12 Cables Total A + B + C, volts Maximum Allowable Voltage Drop = 3.60 volts (3% of Line Voltage) LAM 3-LAM 4-LAM 12 Cable 10 Cable 12 Cable 10 Cable VLTAG D F 120 VLTS Cable Cable C - ATCL SC. The provisions of this article apply to field-installed wiring using off-site manufactured subassemblies for branch circuits, remote control circuits, signaling circuits, and communications circuits in accessible areas DFT. Manufactured iring System: A system containing component parts that are assembled in the process of manufacture and cannot be inspected at the building site without damage or destruction to the assembly TH ATCLS. xcept as modified by the requirements of this article, all other applicable articles of this Code shall apply USS MTTD. The manufactured wiring systems shall be permitted in accessible and dry locations and in plenums and spaces used for environmental air, where listed for this application, and installed in accordance with Section xception o.1: n concealed spaces, one end of tapped cable shall be permitted to extend into hollow walls for direct termination at switch and outlet points. xception o. 2: For use in outdoor locations where listed for the purpose USS T MTTD. here conductors or cables are limited by the provisions in Articles 333 and CSTUCT. A) Cable or Conduit Types. (1) Cable shall be listed armored cable or metal-clad cable containing nominal 600-volt o.10 or 12 copper-insulated conductors with a bare or insulated copper equipment grounding conductor equivalent in size to the ungrounded conductor. (2) Conduit shall be listed flexible metal conduit or listed liquid tight flexible conduit containing nominal 600-volt o.10 or 12 copper-insulated conductors with a bare or insulated copper equipment grounding conductor equivalent in size to the ungrounded conductor. xception o.1 to (1) and (2): A fixture tap maximum 6 ft (1.83m) long intended for connection to a single fixture shall be permitted to contain conductors no smaller than o. 12 but not smaller than o.18. xception o.2 to (1) and (2): Conductors smaller than o. 12 shall be permitted for remote-control, signaling, or communication circuits. The assembly shall be listed for the purpose. (3) ach section shall be marked to identify the type of cable or conduit. B) eceptacles and Connectors. eceptacles and connectors shall be locking type, uniquely polarized and identified for the purpose, and shall be part of a listed assembly for the appropriate system. C) ther Component arts. ther component parts shall be listed for the appropriate system UUSD UTLTS. All unused outlets shall be listed for the appropriate system. 14
16 For lectro/connect assistance, literature, and templates contact your local Day-Brite epresentative Form # MC7.5M Day-Brite Lighting 776 South Green Street Tupelo, MS hone Fax
lumenalpha spot Specification Sheet
Client Project name Order# Type Qty FEATURES AND BENEFITS Physical Housing material: extruded aluminum Available in or 8 sections Finish: black or white Ceiling mounting: surface or recessed Wall mounting:
More informationAPPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors
PPLINCES /// MT, CST-100 II ND SL-156 CONNECTORS CONNECTORS/ PPLINCES MT, CST-100 II and SL-156 Connectors Contents Introduction This catalog has been designed to assist you, our customer, identify products
More informationThe Chan-L-Wire Pro Series Lighting Distribution
Lighting Distribution System Offers Maximum Flexibility The Chan-L-Wire Pro Series Lighting Distribution System offers maximum flexibility while saving up to 40% in labor installation costs. The system
More informationBROCHURE MC LUMINARY CABLES
BROCHURE MC LUMINARY CABLES MC Luminary HCF Lite/Tuff MC Luminary Multizone Lite/Tuff MC Lite Luminary Cable MC Tuff Luminary Cable MC Luminary Jacketed Cable WHAT A BRIGHT IDEA! A PART OF AFC Cable Systems
More informationIndyGo Facility Upgrades Project 35671EE
SECTION 260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Identification for raceways. 2. Identification of power and control cables. 3. Identification for
More informationREAD THESE INSTRUCTIONS COMPLETELY AND CAREFULLY
06.18.18 BEFORE YOU BEGIN Determine your light bar mounting method. Are you using pre-existing sockets to mount? If so, Retrofit Connectors are included. If not, be sure to purchase our Speed Spring Brackets
More informationBROCHURE NEW 10 AWG MODULAR WIRING SYSTEM FOR LIGHTING. Suspended Ceiling and High & Low Bay Lighting Applications A PART OF
BROCHURE NEW 10 AWG MODULAR WIRING SYSTEM FOR LIGHTING Suspended Ceiling and High & Low Bay Lighting Applications A PART OF Table of Contents Overview of ACS and Modular Wiring Systems for Lighting...3
More informationSafety Codes Council Conference Banff C Panel Discussion
Safety Codes Council Conference Banff 2014 90 C Panel Discussion Tim Driscoll OBIEC Consulting Ltd. George Morlidge Fluor Canada Ltd. Scott Basinger Eaton Canada René Leduc Marex Canada Limited Perspectives
More informationHARTING Ethernet cabling cables and connectors, 4 wire
Industrial Cat. 5e Standard cable, 4-wire Type A for permanent installation or to build-up PROFINET system cables PVC X 8 wire X Cat. 5e X Cat. 6 Cat. 6 A Cat. 7 Cable structure Core structure Wire insulation
More informationACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE
MANUAL PART NUMBER: 400-0109-001 PRODUCT REVISION: 1 PNP202 Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the PNP202 Interconnect Box is greatly appreciated. We are sure you will find it
More informationEZ-STATUS WLS28-2 Multicolor LED Strip Light
EZ-STATUS WLS8- Multicolor LED Strip Light Datasheet Banner's WLS8- Multicolor LED Strip Lights have sturdy aluminum housings, shatterproof windows, and environmental ratings that make it ideal for harsh
More informationSITE All work shall be performed at Center Park Substation (1895 Kernan Blvd, Jacksonville, Fl ). DATE: 04/03/2018
DATE: 04/03/2018 TO: The Contractor FROM: System Protection & Control Projects 20413 SUBJECT: Technical Specifications for Center Park APSTF Project PROJECT OVERVIEW This is a general specification that
More informationMTA, CST-100 II, SL-156 and AMP Economy Power (EP) Connectors. NOT the LATEST REVISION
MP Economy Power (EP) Connectors NOT the LTEST REVISION Table of Contents 2 Introduction This catalog has been designed to assist you, our customer, identify products to satisfy your connector needs for
More informationINSTALLATION INSTRUCTIONS FOR
INSTALLATION INSTRUCTIONS FOR MODEL 2240LED www.sportablescoreboards.com 1 Table of Contents 8 X 7 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR
More informationSCIR. Infrared Illuminator Powerful Indoor/Outdoor IR Spotlight SCIR
SCIR Infrared Illuminator Powerful Indoor/Outdoor IR Spotlight The NetMedia SCIR Infrared (IR) Illuminator provides night vision for IR (850nm) sensitive cameras. It enables cameras such as NetMedia s
More informationFLUID VIEW 12V LED TAPE LIGHT
DRY LOCATION FLUID VIEW 12V LED TAPE LIGHT Medium brightness Available in 8+ CRI 16.4 ft. maximum run UL Listed & R/C SAM Manual Suitable for closet use 5-Year limited warranty SUITABLE FOR CLOSET USE
More informationCoastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents
PART 1 - GENERAL 1.1 SUMMARY SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors. 3. Cabling system identification products. 1.2
More informationOPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION
L0 CALL -800--600 OPTEVA 88 LOBBY ATM FRONT LOAD WITH 0mm ( 6") CEN III AND CEN IV SAFE CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE PLANNING AND
More informationVITALink Taped Splice Straight Through Crimp
A Marmon Wire & Cable Berkshire Hathaway Company VITALink Taped Splice Straight Through Crimp 2 Hour Fire-Rated Splice VITALink MC Cables, UL FHIT 120 Installation Instructions Description The VITALink
More informationAMERICAN NATIONAL STANDARD
Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 129 2017 Drop Passives: Bonding Blocks (Without Surge Protection) NOTICE The Society of Cable Telecommunications Engineers (SCTE) Standards
More informationchoice of types to suit many applications, from simple containers, toolboxes, industrial canister type vacuum cleaner, insulation
Solutions Inc. TL-7800 Line The DFCI TL-7800 Line of Toggle Latches offers the designer a wide choice of types to suit many applications, from simple containers, toolboxes, industrial canister type vacuum
More informationENCAPSULATED TRANSFORMERS FOR HARSH LOCATIONS
SECTION ENCAPSULATED TRANSFORMERS FOR HARSH LOCATIONS 600 Volt Class, Encapsulated Single Phase and Three Phase Description and Applications... 8 Copper NEMA R Features... 8 Copper Single Phase Selection
More informationDistributed Design Series
D10SUB 10-INCH FEATURES Powerful, high-impact bass response Internal passive low-pass crossover Spring loaded Drop-Stop installation assistant tabs support the back can on the included rails and C-ring
More informationWLB SERIES HID Lighting for Hose Down Applications
WLB SERIES W LB HID Lighting for Hose Down Applications Class II, Division 2, Groups F & G Class III UL 844 Hazardous Locations UL 1598 Wet Locations NEMA 4X NSF Certified Food Equipment CUL Heavy Hose
More informationACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE
MANUAL PART NUMBER: 400-0091-001 PRODUCT REVISION: 1 TNP100 Tilt N Plug Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the TNP100 Tilt N Plug Interconnect Box is greatly appreciated. We are
More informationSeries CDP2 Definite Purpose Contactors
Series CDP2 Definite Purpose Contactors High performance economical contactors for commercial applications up to 90 Sprecher + Schuh s Definite Purpose contactors are ideal for commercial applications
More informationXML LED X M L L E D. Explosionproof Linear LED Lighting
LED Class I, Division 1, Groups C & D Class I, Division 2, Groups C & D Class II, Division 1, Groups E, F & G Class III Simultaneous Presence UL 844 Hazardous Locations IEC Ex d Zone 1 Equivalent UL 924
More informationChurch Layout Medium Advanced
Specifier Product Information Church Layout Medium Advanced System Summary This summary is intended to explain, in general terms, some of the possible uses and reasons for having the recommended equipment
More informationDimensions. Electrical Specifications. Environmental Specifications. General Specifications. Mechanical Specifications.
CPC331T-01 GS8E-XT1-BK GigaSPEED XL GS8E T1 Crossover Stranded Cordage Modular Patch Cord, Black Jacket Dimensions Cord Length, maximum 30 m 100 ft Cord Length, minimum 1 m 1 ft Electrical Specifications
More informationINSTALLATION INSTRUCTIONS FOR. MODEL 2230LED
INSTALLATION INSTRUCTIONS FOR MODEL 2230LED www.sportablescoreboards.com 1 Table of Contents MODEL 2230LED... 3 8 X 4 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:...
More information2002 Martin Professional A/S, Denmark.
Freekie user manual 2002 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Martin Professional
More informationHorizontal or Vertical PCB contacts Bulk Packaging LED colour - Red, Green, Yellow or Blue combinations. Ordering Codes
XLRnet CONNECTORS XLRnet CONNECTORS XLRnet was designed in conjunction with the Amphenol Data / Telecom product group of Amphenol Canada Corp., a subsidiary of Amphenol Corporation. Utilising our combined
More informationPower and Control T YPE BY RAVI GANATR November/December IAEI NEWS
Power and Control 26 1999 November/December IAEI NEWS T YPE BY RAVI GANATR This article discusses how the requirements in both the installation code and the product standard are utilized to manufacture
More informationSECTION COMMUNICATIONS HORIZONTAL CABLING
SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors including patch panels. 3. Cabling identification
More informationPROJECT DATE LENS SF FLANGE FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)
PROJECT INFORMATION PROJECT DOWNLIGHT DATE TYPE 1" 2-1/2" BeveLED Recessed Downlight - Illuminate your space with any color available in the spectrum with BeveLED Infinite Color+. Tune the light from saturated
More informationACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE
MANUAL PART NUMBER: 400-0091-003 TNP500 Universal Tilt N Plug Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the TNP100 Tilt N Plug Interconnect Box is greatly appreciated. We are sure you
More informationNational Wire and Cable and National Cable Molding Headquarters Los Angeles California
National Wire and Cable and National Cable Molding Headquarters Los Angeles California CAPABILITIES Medical Business Machines Communications Equipment Computer Equipment Audio Systems General Instrumentation
More informationHN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/
Connectors Introduction 2004 Automatic Connector. All rights reserved. pdf 1.0 4-13-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable
More informationThree Phase - General Purpose. THREE PHASE: 3 kva - 9 kva Epoxy Encapsulated Series 76 ISO-Shield
26 THREE PHASE: 3-9 Epoxy Encapsulated Series 76 ISO-Shield Features UL Listed, File E3210. CSA Certified, File LR 560. Electrostatic shield between primary and secondary windings provides cleaner output
More informationProcessing Specification MiniBridge IDC
Processing Specification MiniBridge IDC ERNI Electronics GmbH & Co. KG Seestrasse 9 l 73099 Adelberg / Germany l +49 7166 50-0 l www.erni.com Version 5 IMS Verarbeitungsspezifikationen Seite 1 von 11 Table
More informationAzatrax Model Railroad Track Signal Control - Single Track
Installation Guide Azatrax Model Railroad Track Signal Control - Single Track TS2 What it is: The TS2 operates one or two trackside block signals (one in each direction) on one track to simulate the block
More informationCalifornia Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.
PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated
More informationINSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD
1 INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD NOTE TO INSTALLERS: PLEASE RETURN THIS MANUAL TO THE INDIVIDUAL IN CHARGE OF THE SCOREBOARD UPON COMPLETION OF INSTALLATION. The scoreboard
More informationWire Connector, Wire Size 18 to 12 Gauge; Yellow; Standard Package 100 Per Box; Approval Ul; Scotchlok[T] Brand
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 YB0X 18-12 Scotchlok Minnesota Mining (3M) Catalog Number Manufacturer Weight per unit Product Category YB0X Minnesota
More information8341LS PRODUCT SPECIFICATIONS MODEL 8341LS LED BASEBALL SCOREBOARD OUTDOOR SCOREBOARD. Baseball 10-Inning Line Score
OUTDOOR SCOREBOARD 8341LS Baseball 10-Inning Line Score OVERALL DIMENSION INFORMATION DISPLAYED DIGITS INDICATORS CAPTIONS HORN CONSTRUCTION STANDARD COLORS (Custom Colors Available) 9 1/2 high x 32 wide
More informationTeamWork Kits Installation Guide
TX 0 RX COM +5V APARATUS US TeamWork Kits Installation Guide TeamWork 400 and TeamWork 600 Kits The TeamWork 400 and TeamWork 600 kits consist of an HDMI switcher, system controller, Cable Cubby, and cables
More informationSPECIFICATION SHEET lumencove
Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS Physical : Low copper content extruded aluminum housing Available in 1, 2, 3, 4 or sections Electro-statically applied polyester powder coat
More informationInstruction Manual MODEL RSP SANITARY ELECTRONIC PRESSURE TRANSMITTER
Instruction Manual Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY 12072 1-800-833-0081 Fax 518-922-8997 www.andinst.com Instrument Model Number Instrument Serial Number MODEL RSP SANITARY
More informationKEL 24 Cable entry frames
24 Cable entry frames Split inserts Description Type Order No. Inserts KT PU small large The 24 matches exactly the cut-out dimensions of 24-pole standard industrial connectors. 24 42241 - The split insert
More informationSPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment
2004 Specifications CSJ 3256-02-079 & 3256-03-082 SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 1. Description. Furnish and install Fiber Optic Video Data Transmission Equipment
More informationCOMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationBroadcast Interconnect Solutions CONNECTING INNOVATION TO APPLICATION
Broadcast Interconnect Solutions CONNECTING INNOVATION TO APPLICATION Contact Information NORTH AMERICA United States Winchester Electronics World Headquarters 62 Barnes Industrial Road North Wallingford,
More informationSite Installation Model MP-8424
Site Installation Model MP- Rev. //0 SCOREBOARD SITE INSTALLATION INSTRUCTIONS CAUTION: All American Scoreboards (AAS) recommends the sign be installed by a licensed contractor, and must meet all local
More informationPCR AUTOMATIC HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More informationFollow The Leader In Shielded Technology
1970s Vampire Tap 1990s Shielded Modular Jack 190s 4 Position Data Connector Follow The Leader In Shielded Technology The new AMP-TWIST Jack is our latest shielded product evolution. It can be terminated
More informationUltra Quiet Series Electric Air Handler
Residential & Light Commercial HVAC Ultra Quiet Series Electric Air Handler 1 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz The Fedders multi-position air handlers, when matched with our air conditioners
More informationTender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*
Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab* General Scope of Work: Supply and installation of Computer Laboratory setup in MIU Location of Installation:
More informationNon Magnetic Connectors
Non Magnetic Connectors Johnson Components builds coaxial connectors using innovative materials and design to provide Mil Spec Performance at a commercial price. Now we offer our Non Magnetic Connectors
More informationSPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment
1993 Specifications CSJ 0500-01-117 SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic Video
More informationOptical Distribution Box 300 Installation Guide. Version : R0.0
Optical Distribution Box 300 Installation Guide Document No. : OD16-546-L-01 Version : R0.0 Date: 21-Mar-2018 IMPORTANT INSTRUCTIONS When using fiber optic equipment, basic precautions should always be
More informationPOWER SUPPLIES COAX DC INSERTERS SITUATION
SITUATION devices require voltage on the coax output connector and RF signals must pass from input to output on the power inserter. SOLUTION Sonora power inserters couple regulated voltage on coax cables
More informationFLAT AND ROUND CABLE PRODUCT DESCRIPTION DESIGN ADVANTAGES. IDC Systems Cable
Cable PRODUCT DESCRIPTION Thomas & Betts flat cable provides the means to reduce mass and weight in flexible wiring assemblies. Available with PVC, TPE or FEP insulation, the cable is extruded to provide
More informationModular Lube Lubrication Systems System Controls
Model 84501 Program Timer Solid State Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid
More information1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment
1993 Specifications CSJ 0922-33-042, etc. SPECIAL SPECIFICATION ITEM 8549 CCTV Central Equipment 1. Description. This Item shall govern for the furnishing and installation of closed circuit television
More informationNORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017
SECTION 26 0553 - IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationR OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL
OPTEVA 868 THROUGH THE WALL ATM WITH 40mm ( 6") CEN III AND CEN IV SAFE L0 CALL -800--600 0 (6") REQUIRED FOR WALLS EXCEEDING 0mm (2") CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS
More informationSystem 500. Non-fire-rated, mineral insulated copper sheathed wiring cable
Non-fire-rated, mineral insulated copper sheathed wiring cable For retrofitting feeders in buildings and for ease of installation in tight spaces and difficult runs Cable construction Solid copper conductors
More informationModular pulse operated latching relay 16 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Modular pulse operated latc / 05 / 07 / 08 / 10 / 11 / 12 / 14 / 16 / 20 and 927 00 / 49 CONTENTS PAGES 1. Description,
More informationContent BULK CABLES VIDEO CABLES AUDIO CABLES EXTENDERS USB CABLES ETHERNET CABLES VIDEO BALUNS CONNECTORS ADAPTERS PATCH PANELS & WALLPLATES TOOLS
Content BULK CABLES VIDEO CABLES AUDIO CABLES pages 2-8 pages 8-12 pages 12-13 EXTENDERS ETHERNET CABLES USB CABLES page 13 pages 14-15 pages 16-17 CONNECTORS ADAPTERS VIDEO BALUNS pages 17-23 pages 23-25
More informationThe Custom Interconnect Leader TM
LC Series.5.188.685 ELECTRICAL Nominal Impedance: Frequency Range: Voltage Rating: Dielectric Withstanding Voltage: Insulation Resistance: VSWR: 50 ohms DC to 1.0 GHz 5,000 volts rms 3,000 volts rms 5,000
More informationAutomatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces
Automatic s 2004 Automatic. All rights reserved. pdf 1.0 3-18-04 Contents Specifications........................... 2 Straight Cable Plugs...................... 3 Right Angle Cable Plugs...................
More informationTelemetry Receiver Installation Guide
BBV Telemetry Receiver Installation Guide Models covered Rx200 Building Block Video Ltd., Unit 1, Avocet Way, Diplocks Industrial Estate, Hailsham, East Sussex, UK. Tel: +44 (0)1323 842727 Fax: +44 (0)1323
More informationSECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.
SECTION 33 71 49.23 MEDIUM VOLTAGE CABLE INSTALLATION PART 1 GENERAL 1.1 SCOPE A. Work included in this Section: Medium Voltage Cable (4 kv and 12 kv) Installation and Termination. Removal and return of
More informationWire Connectors FAX WIRE CONNECTORS. Quick, reliable splices are a snap and a squeeze
Wire s Spring s and Tools 32 Crimp Sleeve s 37 Insulation Displacement s and Tools 38 Scotchlok s and Tools 42 Moisture Guard 46 3M Scotchlok 557 IDC WIRE CONNECTORS we design connectors that are as comfortable
More informationLumencove Family. The highest quality light from the tightest spaces
Lumencove Family Lumencove Family The highest quality light from the tightest spaces The Lumencove family of products utilizes aiming and dimming capabilities that provide complete control of cove lighting
More informationLiner Quattro AC XB RGBW
Date: Quantity: Company: Project: Liner Quattro AC XB RGBW The Liner Quattro AC XB RGBW is an AC line powered, high brightness luminaire. The luminaire is controllable via DMX512 with auto-addressing for
More informationContinuous Currents. When inspectors see a photovoltaic (PV) power system. through Curious Cables. by John Wiles
PV Wiring: Continuous Currents through Curious Cables by John Wiles When inspectors see a photovoltaic (PV) power system for the first time, they will usually be faced with a type of wiring method not
More informationFiberglass - Technical Data
- Technical Data Cable Tray Thermal Contraction and Expansion X : Denotes hold-down clamp (anchor) at support. _ : Denotes expansion guide clamp at support. It is important that thermal contraction and
More informationCable Installation Tips
Cable Installation Tips Campus Network Design & Operations Workshop These materials are licensed under the Creative Commons Attribution-NonCommercial 4.0 International license (http://creativecommons.org/licenses/by-nc/4.0/)
More informationSite Installation Model MP-8433
Site Installation Model MP- Rev. //0 SCOREBOARD SITE INSTALLATION INSTRUCTIONS CAUTION: All American Scoreboards (AAS) recommends the sign be installed by a licensed contractor, and must meet all local
More informationManual #: UMA1074 Rev. 2 October, Hall Research Technologies, Inc 1163 Warner Ave. Tustin, CA 92780
Component Video / VGA Over UTP Video Transmission Systems Manual #: UMA1074 Rev. 2 October, 2007 Hall Research Technologies, Inc 1163 Warner Ave. Tustin, CA 92780 Table of Contents 1.0 GENERAL DESCRIPTION...
More informationTE Connectivity DEUTSCH DL Series MIL-DTL Series III Connectors
Applications Features TE Connectivity DEUTSCH DL Series MIL-DTL-83723 Series III Connectors High-performance military aircraft Commercial aircraft Communications equipment Armored personnel carriers &
More informationPREMIUM 5e F/UTP PRODUCTS
Siemon s end-to-end cabling system is guaranteed to provide transmission performance margins in excess of industry standards for category 5e parameters, while featuring excellent EMI resistance. has been
More informationConnecting cables NEBS, for sensors
Connecting cables NEBS, for sensors Connecting cables NEBS, for sensors Product range overview Function Version Type code Connection technology (Electrical connection 2) Connecting cable Cable characteristic
More information2-Piece LED Emergency Back-Up and Kits
MAY 2018 2-Piece LED Emergency Back-Up and Kits 2 OPTIONS AVAILABLE STANDARD LED EMERGENCY BACK-UP For LED Fixtures Includes Driver and Battery The LED emergency back-up enables emergency lighting solutions
More informationTarget Interface / Construction Compliance Inspection Checklist
A. Targets Quantities meet DD, applicable TC -, and CEHNC Design Guide 0-- (Standard is single UTOs and Double UTOs) B. Roads-Service, Lanes Adequate access is provided to the and AAR D. Testing Results-provided
More informationEXPlora. Introduction
Introduction EXPlora The EXPlora range is most suited to manufacturers of ancillary electrical equipment such as motors, pumps, lighting equipment, process and control gear for use in factories and plant
More informationTeamWork Installation Guide
C G G 00-0V/ A MAX TX RX +V APARATUS US 0 TeamWork Installation Guide TeamWork TeamWork is a fully customizable collaboration system comprised of an switcher, Show Me cables, a control processor, and a
More informationOperating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA
Operating Manual Automated Gear Apollo Design Technology, Inc. 4130 Fourier Drive Fort Wayne, IN 46818 USA PH: +01(260)497-9191 FX: +01(260)497-9192 www.apollodesign.net 11-25-09 5-6 POWERING UP THE RIGHT
More informationSPECIAL SPECIFICATION 6735 Video Optical Transceiver
2004 Specifications CSJ 0924-06-244 SPECIAL SPECIFICATION 6735 Video Optical Transceiver 1. Description. This Item governs the furnishing and installation of Video optical transceiver (VOTR) in field location(s)
More information2014 Product Catalog
2014 Product Catalog What are the CleanStage products? CleanStage products are a toolkit for cabling your event s stage with signal and power, providing maximum time savings, operational efficiency, and
More informationMovable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability
Compare These Features Built-in Shock bsorber Reduces contact bounce for longer life. Coil Dust Cover Keeps dust and dirt away from magnet and coil area. Coil Class B (1300 C Insulation System) with wide
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS M9700 RGB SERIES Installation should be performed by a qualified electrician in accordance with the National Electrical Code and relevant local codes. Hydrel's M9700 Series of
More informationART2000i Digital Dimming System. Installation guide. Stock number *8200-
ART2000i Digital Dimming System Installation guide Stock number 8200-0159 *8200- 0159* Useful Avolites phone numbers:- Avolites England Sales and service* (+44) (0) 20 8965 8522 Service out of hours* (+44)
More informationModel Material Lamp type LED color Voltage Distribution Lens
4426 SERIES LED Wet Niche Swimming Pool DMX Color Changing CATALOG NUMBER NOTES TYPE Specifications L: 10-3/8 264 mm W: 11-1/4 286 mm H: 11-1/4 286 mm Weight lbs 11 1/4" (286) 8 7/8" (225) 1" (25) 1 3/8"
More informationConnectivity accessories by Nestor Cables
Connectivity accessories by Nestor Cables NesCon product family includes essential installation and connection accessories for fibre optic networks, from ODFs to joint closures and terminations. www.nestorcables.com
More informationIdentification - electrical services
Identification - electrical services Aesthetic All live phase cable sheathing to be brown coloured and neutral phase cable sheathing to be blue coloured, all labelled L1, L2, L3 & N respectively in accordance
More informationContactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B
Contactors Applications Type DP provide high performance with flexibility and reliability, designed to match numerous applications including: Motors Power supplies Food service equipment Compressors Business
More informationINSTALLATION AND OPERATION MANUAL
Lightolier 8-8A0 /8/0 : AM Page IMPORTANT: RETAIN THESE INSTRUCTIONS FOR THE END USER. DO NOT DISCARD. INSTALLATION AND OPERATION MANUAL A B C D E F G H MULTISET PRO - PRE-WIRED DIMMING CABINET MDC COMPATIBLE
More informationw w w.w h y t e t e c h n o l o g i e s.c o m.
INTEGRATED RECEPTION SYSTEMS w w w.w h y t e t e c h n o l o g i e s.c o m. About Whyte Technologies Whyte Technologies is a leader in the research, design and manufacture of TV and Satellite Distribution
More information