1 African Development Bank Group African Development Bank's Field Office in Abuja, Nigeria LOT 5A: VOL 3 - BILLS OF QUANTITIES: IT WORKS Prepared by Interstate Architects Ltd. In Conjunction with: IAA Associates Ltd. KOA Associates Ltd. & Construction Economists Partnership Ltd.
2 ITEM BILL No. 1 - ELECTRICAL SERVICES: COMMUNICATION SYSTEMS INSTALLATION Supply,install, commission and maintain for 1 year defect liability period and/or waranty the following: -Contractor shall include report, brochures and schematic diagrams including method statement for this service. Non compliance may disqualify bid - All products to be cisco or approved equal. Installer/supplier to ensure that Equipment selection are carried out such appropriate hierearchy are maintained at all times -System to be supplied c/w all required equipment/devices for effectice operation of the entire installation. -All products to be supplied c/w the propreitary software, accessories etc -All products and software to be the the most recent/current at the time of delivery. - All servers to be supplied c/w appropriate/approved billing software - All cables to be backward compliant - A uniform wiring scheme of T568B is to be used through out the system TELEPHONE AND DATA SYSTEM Conduit & Accessory boxes 1 25mm dia upvc conduit c/w draw wire to each RJ45 outlets from terminal cases, MDF and telecomms rack in IT room etc. 528 No 2 Cat 7 utp cable from the Telecomms racks to each RJ45 outlet etc. 528,, e.g. Systimax, Avaya or approved equal 3 4core optic fibre cable(back-bone) c/w termination kits and color coded (RED, BLUE) for ease of identification e.g Avaya 50 m Cable Trays & PVC-U Pipes /Trunkings 4 225mmW x 50mm covered galvanised cable tray with admiralty pattern c/w all accessories such as bends,tees, end caps, couplings, Supports, brackets etc. to be color coated BLUE for vertical IT riser 400 m 5 150mmW x 50mm covered galvanised cable tray with admiralty pattern c/w all accessories such as bends,tees, end caps, couplings, Supports, brackets etc. to be color coated BLUE for vertical IT riser 180 " 6 170x50mm 3-compartment skirting trunking c/w covers, bends,couplers retainers, corners, accessory boxes etc. e.g. MK Prestige Plus Profile M or approved equal 100 " 7 150x28mm 3-compartment galvanised steel(or PVC-U) underscreed trunking c/w vertical access box, end caps, couplers, brackets, concealed service boxes etc. e.g. MK Ega Slimeline Flushfloor SLT 150/3 or approved equal 600 " 8 150x28mm 3-compartment galvanised steel(or PVC-U) underscreed junction box for the above e.g. MK Ega Slimeline Flushfloor SLJ 150/3C or approved equal 50 No 9 150x28mm 3-compartment galvanised steel(or PVC-U) vertical access box e.g. MK Ega Slimeline Flushfloor or approved equal 24 " Page 1/1 To Collection AfDB: IT SECURITY BoQ 1
3 ITEM BILL No. 1(Contn'd) - ELECTRICAL SERVICES: COMMUNICATION SYSTEMS INSTALLATION Cable Trays & PVC-U Pipes /Trunkings (cont'd) x250mm Concealed service outlet box adaptors c/w compartment reducers e.g. MK Ega Slimeline Flushfloor FXSA 250/ SLR or approved equal 90 " mm diameter upvc pipe c/w all accessories Lot 12 50mm diameter upvc pipe c/w all accessories Lot 13 20mmD flexible conduit Lot Equipment, Accessories & Cables 14 Optic Fibre patch panel c/w cable management mechanism and wired to the adopted system's wiring scheme e.g. Cisco or approved equivalent 1 No port Cat 7 System Patch Panel with T568B color code connector e.g Cisco or approved equivalent 10,, port Cat 7 System Patch Panel c/w cable management mechanism e.g Cisco or approved equivalent 2,, 17 Surge arrestor catridges 1,, 18 Free standing and 45U Telecommunication cabinet (rack) capable of hosting all standard equipment types and shall be complete with multi-outlet power supply, earthing set, closed front metallic patch guides between patch panels, lateral rings, cable mangement accessories etc. e.g. Panduit or Approved Equal 2 " 19 Wall mounted 42u equipment rack with glass front and lock c/w earth bar, power distribution unit, cable management accessories, patch guide etc e.g. Panduit or Approved Equal 6 " 20 Flush 2-gang switch module comprising of the following; - Cat. 7 utp RJ45 socket with cover plate for telephone and data with both T568A & T568B color codes identification at the rear of the connector 248 " e.g Legrand Galea ( )or Approved Equal 21 Flush 1-gang switch module comprising of the following; - Cat. 7 utp RJ45 socket with cover plate for telephone with both T568A & T568B color codes identification at the rear of the connector 32 " e.g Legrand Galea ( )or Approved Equal 22 3 metre long Cat 7 utp patch leads with T568B color code Lot Page 1/2 To Collection AfDB: IT SECURITY BoQ 2
4 ITEM BILL No. 1(Contn'd) - ELECTRICAL SERVICES: COMMUNICATION SYSTEMS INSTALLATION telephone and data systems (contn'd) 23 Allow for optic fibre patch cords,screened series connectors, couplers, multimode, consumables and transducers, clips, terminal blocks, labelling, catridge etc for system installation. Lot 24 Connection to external network including surge diverters as specified ( telephone system) Lot 25 Allow for 1c 2.5mm2 TPE earthing cables from the rack to the wall mounted earth terminal in the server room Lot 26 Training (with attendance certificates) of personnels for maintenance works Sum * to be videotaped Page 1/3 To Collection COLLECTION Page 1/1 Page 1/2 Page 1/3 Page 1 TO SUMMARY - AfDB: IT SECURITY BoQ 3
5 ITEM BILL No. 2 - ELECTRICAL SERVICES: UPS DISTRIBUTION INSTALLATION Supply,install, commission and maintain for 1 year defect liability period and/or waranty the following: Conduit Cables, Accessory boxes for Final Circuits 1 20mm dia PVC-U conduit wired in radial circuit using 1c 2.5mm2 PVC cable to each 13A CLEAN and RAW power SSO, and flex etc. c/w separate CPC (earth wire) per circuit accessory boxes etc. 300 No Wiring Accessories 2 13A twin-gang switchsocket outlet with red moulded coverplate c/w screw plug as CLEAN power outlet e.g. Legrand Milac or approved equal 300 " Page 2 TO SUMMARY - AfDB: IT SECURITY BoQ 4
6 1 Bill No. 1 - COMMUNICATION SYSTEMS 2 Bill No. 2 - UPS CABLING SUMMARY Sub-Total - - TOTAL AfDB: IT SECURITY BoQ 5
HighBand 25. TrueNet Category 6 Solutions
HighBand 25 TrueNet Category 6 Solutions The highest performing cross-connect system in the world. A unique high-density solution with superior cable management. ADC KRONE s HighBand 25 cross connect solution
More informationREQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus
REQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus PART 1: GENERAL REQUIREMENTS A. Contractor Work 1. Provide and install (except as noted in this document), cable,
More informationCoastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents
PART 1 - GENERAL 1.1 SUMMARY SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors. 3. Cabling system identification products. 1.2
More informationLCS2 Cat. 6 RJ 45 Patch panels and units
87045 LIMOGES Cedex Telephone: 33 0 5 55 06 87 87 - Fax: 33 0 5 55 06 88 88 LCS2 Cat. 6 RJ 45 CONTENTS Page 1. General characteristics....1 2. Presentation...2 3. Installation...2 4. Technical characteristics...2
More information19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43
19" TiRAX cabinet system from page 3 19" NETcell cabinet system from page 31 Open 19" racks from page 43 all-mounting/stand-alone distribution systems from page 53 all-mounting enclosure systems from page
More informationLEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION
LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION 14 LCS 2 Copper A complete system for higher performance Connectors See pages 16 to 19 LCS 2 copper Patch panels See pages 21 to
More informationAugust " BLANK PATCH PANEL FOR STP KEYSTONE JACKS. 19" PATCH PANEL - 24x STP CAT6A PORTS 19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS
19" BLANK PATCH PANEL FOR STP KEYSTONE JACKS WITH EXTRA LONG STRAIN RELIEF BAR The 24-port blank patch panel is designed to use with STP keystone jacks. It can hold up to 24 RJ45 keystone jacks. It features
More informationBILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School
BILOXI PUBLIC SCHOOL DISTRICT Biloxi Junior High School Request for Proposals E-Rate 2014-2015 - Internal Connections Submit Proposals To: Purchasing Department Attn: Traci Barnett 160 St. Peter Street
More informationFollow The Leader In Shielded Technology
1970s Vampire Tap 1990s Shielded Modular Jack 190s 4 Position Data Connector Follow The Leader In Shielded Technology The new AMP-TWIST Jack is our latest shielded product evolution. It can be terminated
More informationTender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*
Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab* General Scope of Work: Supply and installation of Computer Laboratory setup in MIU Location of Installation:
More informationSECTION COMMUNICATIONS HORIZONTAL CABLING
SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors including patch panels. 3. Cabling identification
More informationA. All communications equipment rooms shall be installed in a neat and workmanlike manner.
SECTION 27 11 00 - COMMUNICATIONS EQUIPMENT ROOM FITTINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationAPPENDIX A Verify All Part Numbers (Partial List of Approved Products)
SECTION 16651 APPENDIX A Verify All Part Numbers (Partial List of Approved Products) SYSTIMAX SCS: OVER-VOLTAGE PROTECTION 1. Over-voltage Protection Device, 100-Pair with Enclosure, Product 489ACAI-100,
More informationEnterprise Networks. Comms Room and Backbone. in DETAIL
Enterprise Networks Comms Room and Backbone in DETAIL 31 Patch Panels 33 CAT 6 CL 16 WAY PATCH PANEL 19 1U Category 6 performance patch panel. Jacks are fitted. Integral cable management and reusable label
More informationHD Flex Patch Panel. ASSEMBLY VIEW (FLEX1UPN** shown) FS128B. CONTENTS: (#) indicates FLEX4UPN** quantity
HD Flex Patch Panel Part Numbers: FLEX1UPN**, FLEX2UPN**, FLEX4UPN** Panduit Corp. 2018 INSTALLATION INSTRUCTIONS Note: HD Flex Patch Panels are compatible with HD Flex Fiber System Components. HD Flex
More informationLCS 2 RJ 45 Cat. 6A HD panels and units
87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: +33 (0)5 55 06 88 88 Page 0 335 85/86 1. General characteristics....1 2. Presentation...1 3. Positioning...1 4. Technical characteristics...1
More informationLANmark. Copper Cabling Solutions
LANmark Copper Cabling Solutions Edition 01/03/2001 Copyright Nexans 2001 Subject to change without prior notice. In this publication, no mention is made of rights with respect to trademarks or tradenames
More informationbtnet new products Modular and preloaded patch panels btnet
btnet new products Modular and preloaded patch panels 128 btnet content 130 General characteristics Catalogue 132 UTP and FTP cable 134 Patch panel and cord 135 Pop-up and floor box 136 Fiber optic BTNET
More informationPeak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide
GB05-7 Peak Atlas IT RJ45 Network Cable Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001/2013 In the interests of development, information
More informationStructured Cabling Introduction & Installation Guide
Structured Cabling Introduction & Installation Guide Structured Cabling Overview General Structure - Cat5e/Cat6 Cabling The structure illustrated has the following key points: Face plates present outlet
More informationHCS - HES Cabling Systems
HCS - HES Cabling Systems Installation Manual for HCS High-Capacity Fiber-Optic Rack-Mount Cabinets Be sure to read and completely understand this procedure before applying product. Be sure to select the
More informationMfgr. Berk Tek ea , Berk Tek ea , Berk Tek ea. Berk Tek ea ,350.
8. Pricing Schedule The undersigned has rd and understands all conditions and terms of RFP 336-, is authorized to submit this proposal on behalf of the company, and hereby offers to perform the services
More informationCity of Winter Springs, FL
City of Winter Springs, FL Request for Quote RFQ/006/17/LS Commission Chambers Audio Visual System Upgrades The City of Winter Springs will be upgrading its Commission Chambers (Chambers) audio visual
More informationLCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS
LCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS Global strength built on local knowledge Legrand is the global specialist in electrical
More informationLANmark PCB patch panel, 1HU INSTALLATION GUIDE. LANmark PCB patch panel, 1 HU
LANmark PCB patch panel, 1HU INSTALLATION GUIDE LANmark PCB patch panel, 1 HU Document information Document reference Release September 2001 Published by Contact address BRO-009 LANmark PP 1HU 0701 Nexans
More information5400 Series Nonmetallic Raceway
5400 Series Nonmetallic Raceway Nonmetallic Raceway with Twin Snap Cover System Available Factory Prewired PREWIRED SURGE COMMUNICATIONS FIBER OPTIC CAT5 Wiremold 5400 Series Raceway provides wire and
More informationUNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE
UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE Prepared in cooperation and approval from BICSI Building Industry Consulting Services International and
More information-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.
Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.6 N LE 3 NEBV Connecting cables for valves Connection technology on left, field device side B2 Socket type B to industry standard,
More informationAVE-301T AVE-301R AVE-304T AVE-308T AVE-316T
VGA and Audio CAT-5 AV Extender AVE-301T AVE-301R AVE-304T AVE-308T AVE-316T User Manual V1.2 www.databay.com.tw www.green-box.com.tw Contents 1. Product Introduction...4 2. Product Features...5 3. System
More informationCAT6 Cable Tester. Operating Manual. Part No TRIAX - your ultimate connection
CAT6 Cable Tester Part No. 157010 Operating Manual TRIAX - your ultimate connection Application For checking CAT 5e and CAT 6 cables, (UTP and STP). Can also be used with BNC coaxial cable and modular
More informationSAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM
SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM COURSE ORIGINATOR Cabling and Conduit K Norgate DATE 23rd August 2013 Amendment 1 5th October 2013 Technical changes - Issued Amendment 2 6th October
More informationMT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products
MT-RJ Product Expansion Now 0 Variants of the MT-RJ Products In response to several customers, the MT-RJ product line has been expanded with an additional six color/key versions. In addition to the original
More informationCABLING STANDARDS FOR
RFB for Wiring in the Outagamie County Courtrooms Attachment B September 1, 2016 CABLING STANDARDS FOR GENERAL The purpose of this document is to provide guidelines for all structured cable installations
More informationThomas R. Proctor High School. Section 4 Telecommunications Breadth Work
Section 4 Telecommunications Breadth Work 71 4.1 Telecommunications System Addition In order for Thomas R. Proctor High School to be considered an emergency data recovery site, emergency power cannot be
More informationInformation & Communications Technology Network Infrastructure Group. Network Infrastructure Standards June 2008
Information & Communications Technology Group Standards June 2008 Appendix F UTP cabling Version 1.1 Appendix F UTP cabling 1. Introduction This Section details the required standards for Unshielded Twisted
More informationBelden IBDN System 10GX 10GX Modules and 10GX Patch Panels
C O M M E R C I A L N E T W O R K I N G C O P P E R 5.6 Belden IBDN System GX GX Modules and GX Patch Panels AX2272 GX Module, Black GX Module The GX Module is a revolutionary punch down UTP connector
More informationSPECIAL SPECIFICATION 8540 Telecommunication Cable
2004 Specifications CSJ 0914-00-307 & CSJ 0914-25-003 SPECIAL SPECIFICATION 8540 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing,
More informationUser Manual. VGA and Audio Cat-X AV Extender V1.0 AVE-301T AVE-301R AVE-304T AVE-308T AVE-316T AVE-304TR AVE-308TR
VGA and Audio Cat-X AV Extender AVE-301T AVE-301R AVE-304T AVE-308T AVE-316T AVE-304TR AVE-308TR User Manual V1.0 www.green-box.com.tw www.data-av.com Contents 1. Product Introduction...4 2. Product Features...5
More informationPreparing a home for TransACT fibre-to-the-premise (FTTP) services
Preparing a home for TransACT fibre-to-the-premise (FTTP) services A guide for builders, telecommunications cablers and home owners transact.com.au For more information call TransACT s FTTP Sales Manager,
More informationConnecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath
Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.6 N LE 3 Function NEBV Connecting cables for valves Connection technology on left, field device side A1 Plug socket type A, EN 175301-803
More informationUNM IT/Telecommunications Guide Specification Labeling 11/07/
Labeling 1 PART 1: GENERAL 1.01 SCOPE OF WORK A. Work covered by this Section shall consist of furnishing labor, equipment, supplies, materials, and testing unless otherwise specified, and in performing
More information1.2 EUREKA Series... from page c.14
.2 EUREKA Series................................................................................................. from page c.4 This latest generation of industrial plugs, connectors and socket outlets
More informationConnected Solutions. April $ Post, 19 Rack ELERK1FR BK
Connected Solutions April 2018 $30.97 Punch & Go Tool ONQAC3400 $139.97 per 305M Category 6 Riser, UTP, 23 AWG, Blue 305 Meter/1000 FT Pull Box CAB24/4PS6FT4BLUHYP $137.97 2 Post, 19 Rack ELERK1FR1194400BK
More information10 PDUs 19 PDUs Zero-U PDUs
128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex - France Tel: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 www.legrand.com 10 PDUs Page 1. GENERL CHRCTERISTICS...1 2. EQUIPMENT ND PERFORMNCE...3
More informationSPECIAL SPECIFICATION 6559 Telecommunication Cable
2004 Specifications CSJ 0015-09-147, etc. SPECIAL SPECIFICATION 6559 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing, training,
More informationPre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017
Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM-2017-2 Date: 05/26/2017 Additional specification information for data communication to cameras and between Library
More information3M Supported Applications Map 100,000 (2005) Single-mode. Fiber. Multimode. Fiber. Copper
3M Volition Network Solutions introduces Category 5e (Cat. 5e) copper cabling system to complement its leading fiber optic structured cabling system. Customers can now enjoy a single source of supply and
More informationCommon Public Radio Interface Fiber :: Telect HDX & ELF CPRI Panels and Modules
Overview Telect's HDX and ELF CPRI Interface Panels and Modules provide non-service affecting monitor ports to be installed between the Optical CPRI Base Band Unit (BBU) and the Remote Radio Head/ Active
More informationMagic Patch Patch Leads & Accessories
Magic Patch Patch Leads & Accessories T: 01376 346600 F: 01376 346620 www.connectixcablingsystems.com Issue 1.1 Magic Patch Cabling Systems TM Magic Patch Connectix Cabling Sytems TM range of patch leads,
More informationCAT6Plus System. Brand-Rex Limited
Brand Rex introduces it's New CAT6Plus Cabling Solution, designed to deliver an optimum performance cabling system. All products in the CAT6Plus system have 3rd party approval* and therefore either meet
More information6000 Series Patch Panel Terminating Instructions
6000 Series Patch Panel Terminating Instructions INTRODUCTION The 6000 Series patch panels include a unique feature not found on any other patch panel. This feature allows you to angle each of the four
More informationSECTION 7 -- CROSS-CONNECT SYSTEMS
DETAIL ENGINEERING REQUIREMENTS AT&T March, 2016 Section 7, ATT-TP-76400 Revised NA SECTION 7 -- CROSS-CONNECT SYSTEMS CONTENTS PAGE 1. GENERAL... 7-2 1.1. Introduction... 7-2 1.2. Cable Holes... 7-2 1.3.
More informationVolition TM RJ45 K5e Jacks
Volition TM RJ45 K5e Jacks Part of our 3M Volition Network Solutions, the new K5e range is our ultimate Category 5e hardware component (ISO/IEC 11801, EN 50173 and ANSI/TIA/EIA-568). The K5e jack is a
More informationRequest for Purchase DESIGN AND INSTALLATION OF STRUCTURED COMMUNICATIONS CABLE SYSTEMS
VOFP Cabling RFP 1 Request for Purchase DESIGN AND INSTALLATION OF STRUCTURED COMMUNICATIONS CABLE SYSTEMS For The Village of Franklin Park 2014 VOFP Cabling RFP 2 TABLE OF CONTENTS I. PROJECT DESCRIPTION
More informationMonash University. Communications Cabling Manual. (Sites running legacy PABXs)
Monash University Communications Cabling Manual (Sites running legacy PABXs) Communications & Networks Information Technology Services Monash University Monash Cabling Specifications (PABX sites)doc Page
More informationBest Friends General Trading FZE
Welcome to Best Friends General Trading FZE Tel. +97 1 50-5426 202, Fax. +971 6 7407428, info@bestfgt.com, besttrd@eim.ae Infrastructure Product Guide Best fgt is UAE based company, operational for last
More informationTender document SPECIFICATION for Wireless. CCTV Surveillance System at KAKRAPAR. GUJARAT SITE Township
य लयर प वर क पर शन ऑफ इ डय लमट ड NUCLEAR POWER CORPORATION OF INDIA LIMITED ( भ रत सरक र क उयम A Government of India Enterprise ) CIN : U40104MH1987GOI149458 KAKRAPAR GUJARAT SITE Tender document SPECIFICATION
More informationLANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU. empty. Clip-on. with Sliding mechanism. Black or white INSTALLATION GUIDE
LANsense Modular Patch Panel for 24 Snap-in Connectors 1 HU empty Clip-on with Sliding mechanism Black or white INSTALLATION GUIDE LANsense Modular Patch Panel for 24 Snap-in Connectors Document information
More informationDescription: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.
Description: OZLINX CAT5e cable has a guaranteed performance; exceeds the Category 5e performance requirements and provides positive PSACR up to 155MHz for bandwidth requirement in the future. Product
More informationSTRUCTURED CABLE SYSTEM (SCS)
PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated
More informationProduct information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated
Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated R512417 966740615 1 Pcs. 090.6102 Metal patch panel with integrated cable tie shelf. 19" 1U HD patch panel 4 12-port/s
More informationConnectivity accessories by Nestor Cables
Connectivity accessories by Nestor Cables NesCon product family includes essential installation and connection accessories for fibre optic networks, from ODFs to joint closures and terminations. www.nestorcables.com
More informationControl cabinet interface and cable entry systems
Modlink MPV Control cabinet interface The Modlink MPV control cabinet interface provides the connection from the control cabinet to the fieldbus environment (outside) in a simple way. Durable connection
More informationHow to Specify MTP Pre-terminated Optical Cabling. January White Paper. Published
White Paper How to Specify MTP Pre-terminated Optical Cabling Published January 2009 The benefits of pre-terminated cabling The two principal advantages of pre- terminated cabling are reduced time on site
More informationEdition 1, August 2011 Copyright 2011 Smart-e (UK) Ltd.
Notice The information contained in this document is subject to change without notice. Smart-e makes no warranty of any kind with regard to this material, including but not limited to, implied warranties
More informationAUDIO ROOF KIT P/N , , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6
AUDIO ROOF KIT P/N 2882064, 2882065, 2882066 APPLICATION Verify accessory fitment at Polaris.com. BEFORE YOU BEGIN Read these instructions and check to be sure all parts and tools are accounted for. Please
More informationCompact Module. Category 6 FTP Cabling System
Compact Module Shielded design for improved EMI performance Suitable for Gigabit Ethernet applications and beyond Ultra-slimline design Colour coded for quick and accurate termination Interchangeable with
More informationThe Uniduct Nonmetallic Latching Raceway
Uniduct One-Piece Latching Raceway The Uniduct Nonmetallic Latching Raceway System is a one-piece single channel design, ideally suited to route and protect fiber optic, UTP, and and other low-voltage
More informationTarget Interface / Construction Compliance Inspection Checklist
A. Targets Quantities meet DD, applicable TC -, and CEHNC Design Guide 0-- (Standard is single UTOs and Double UTOs) B. Roads-Service, Lanes Adequate access is provided to the and AAR D. Testing Results-provided
More informationSPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel
1993 Specifications CSJ 0924-06-223 SPECIAL SPECIFICATION 1160 8:1 Video (De) Mux with Data Channel 1. Description. This Item shall govern for furnishing and installing an 8 channel digital multiplexed
More informationStandard Specification Data Communications Installations
Estates and Facilities University of Reading- Estates and Facilities Standard Specification Data Communications Installations Revision J 1 Context This document applies to works carried out under the control
More informationRequest for Quote E- Rate Eligible Services Scope of Work - Wireless LAN and Cabling for Access Points
Request for Quote E- Rate Eligible Services Scope of Work - Wireless LAN and Cabling for Access Points Due Date: Allowable Contract Date from Posted 470 The Palo Verde Elementary School District is requesting
More informationSmall System Packages. Strand Dimming Systems
12 Dimmer System Model 98502 Two SD 6C dimmer packs 12/24 channel lighting console Rack with locking front door Six 23-50 Zoom spotlights Six 6 inch Fresnels Three 15 foot circuit strips Applications:
More informationUser Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W
User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W Entry Line Fast Ethernet Switch Fast Ethernet Switch with PoE+ for Industrial Use Page
More informationB. Shop Drawings: Show layout and types of-projection screens.. Include the following:
PROJECTION SCREENS - SECTION 11132 1.0 - GENERAL 1.1 Related Documents Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections,
More informationlumenalpha spot Specification Sheet
Client Project name Order# Type Qty FEATURES AND BENEFITS Physical Housing material: extruded aluminum Available in or 8 sections Finish: black or white Ceiling mounting: surface or recessed Wall mounting:
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-27 05 14.00 10 (April 2006) -------------------------------- Preparing Activity: USACE Superseding UFGS-27 05 14.00 10 (April 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationINSTALLATION INSTRUCTIONS FOR
INSTALLATION INSTRUCTIONS FOR MODEL 2240LED www.sportablescoreboards.com 1 Table of Contents 8 X 7 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR
More informationSECTION 4 TABLE OF CONTENTS
Contents Introduction LC, SC and ST Series...4-2 Markets and Applications...4-2 International Standard Documents Compliance...4-2 LC Series Features and Benefits...4-3 LC Standard... 4-4 to 4-5 LC for
More informationCalifornia Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.
PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated
More information42 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall)
42 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall) NOTE: All of these documents are in PDF format located at www.steltronicusa.com To install the 42 LCD
More informationSample Test Project. District / Zonal Skill Competitions. Skill- Electrical Installation. Category: Construction and Building Technology
Sample Test Project District / Zonal Skill Competitions Skill- Electrical Installation Category: Construction and Building Technology Version 1 Dec 2017 Skill- Electrical Installation 1 Table of Contents
More information10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP
0G A is Siemon s advanced, end-to-end augmented category UTP structured cabling system, designed to meet or exceed all 0GBASE-T performance requirements, including alien crosstalk. Siemon s full channel
More informationGE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM
g GE Interlogix Fiber Options Instruction Manual S700V & S702V FIBER-OPTIC VIDEO TRANSMISSION SYSTEM Federal Communications Commission and Industry Canada Radio Frequency Interference Statements This equipment
More informationSTRUCTURED CABLING SYSTEMS (SCS)
STRUCTURED CABLING SYSTEMS (SCS) ModSecur - Structured Cabling Systems (SCS) A Structured Cabling System (SCS) is the backbone of any building, campus or site communication infrastructure. The sharp growth
More informationGF-KSW-48 Series of Fiber Optic Distribution Box. Instruction Manual
Instruction manual GF/KSW/48 Page Nr 1 GF-KSW-48 Series of Fiber Optic Distribution Box Instruction Manual 1. General Introduction GF-KSW-48 series of fiber optic distribution box is applicable to fiber
More informationISS New Audio & Visual installations Design and Physical install guidelines v1.5
ISS New Audio & Visual installations Design and Physical install guidelines v1.5 David Neal 11/05/2018 Contents Background... 3 Installation Standards... 3 Display Screen and Projector positioning... 3
More informationHYPERLINE UTP/STP Cable Strippers and Cutters
198 HYPERLINE UTP/STP Cable Strippers and Cutters UTP/STP Cable Stripper and Cutter, type 110 HT-318 UTP/STP Cable Stripper and Cutter HT-501 Ordering HT-318 HYPERLINE UTP/STP Cable Stripper and Cutter,
More information10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System
10Gb/s Copper Physical Infrastructure Next Generation Category 6A Cabling System Next-Generation Category 6A UTP Cabling System Drivers for 10 GbE Aggregation of Gigabit Links Server Consolidation and
More informationP-2 Installing the monitor (continued) Carry out as necessary
P-2 Installing the monitor (continued) Carry out as necessary Using the monitor without the bezel MDT552S satisfies the UL requirements as long as it is used with the bezel attached. When using the monitor
More informationHome Network Sciences. designer s guide
Home Network Sciences designer s guide 9 10 11 12 13 14 15 16 17 18 19 20 9 10 11 12 About Home Network Sciences Home Network Sciences provides a networking infrastructure to support communications and
More information42 LCD Overhead Video Display Support Specifications Electricity required on the rear curtain wall
42 LCD Overhead Video Display Support Specifications Electricity required on the rear curtain wall NOTE: All of these documents are in PDF format located at www.steltronicusa.com To install the 42 LCD
More informationEdisConnect Modular Cable Kit. Manual and Installation instructions
EdisConnect Modular Cable Kit Manual and Installation instructions General Description EdisConnect is designed to be the ultimate connection system for Audio Visual, pro-audio, pro-video and IT installs
More informationRequest for Quote E- Rate Eligible Services Scope of Work Network Infrastructure and Structured Cabling
Request for Quote E- Rate Eligible Services Scope of Work Network Infrastructure and Structured Cabling Due Date: Allowable Contract Date from Posted 470 The Clarkdale- Jerome School District is requesting
More informationFlexCabling. Hemmaprodukter. Tillbehör. Kontorsprodukter. Övrigt
FlexCabling Hemmaprodukter Skåp 4U Skåp 6U Skåp 9U x 12 (Cat 5E) Management Panel TV/Radio Splitter 1 4 TV/Radio Splitter 1 8 TV- och radiokabel Telefonsplitter Ethernets-switch (Gigabit) Tillbehör AV
More informationTECHNICAL INFORMATION
OCTALUMINA 120: PARTS LIST AND TECHNICAL INFORMATION HIGH POWER LEDS INNER CORNER LABELED FRAME MOUNTED POWER SUPPLY UNIT EASY PLUG-IN CONNECTION BRACING TECHNIQUE CABLE OUTLET AT THE BOTTOM SYSTEM PACKAGING
More information1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment
1993 Specifications CSJ 0922-33-042, etc. SPECIAL SPECIFICATION ITEM 8549 CCTV Central Equipment 1. Description. This Item shall govern for the furnishing and installation of closed circuit television
More information-V- New. Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.
Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.6 N LE 3 Function NEBV Connecting cables for valves Connection technology on left, field device side A1 Plug socket type A, EN 175301-803
More informationpage SALES ENQUIRIES Tel- (03) Fax
Tel- (03) 9727 880 Fax- 1300 30 0 Antenna Outdoor Code 12 Easyfit 1 Economically priced antenna. Suitable for VHF/UHF in prime TV reception areas. Suitable for digital TV applications. (Ch2-12 and 21-3).
More informationIn-Wall Control Mount for ipod Touch
In-Wall Control Mount for ipod Touch INTRODUCTION The Mirage KP-iOS is an in-wall system that allows ipod touch (4th generation) to become a semi-permanent fixture in your wall. The system allows you to
More information