0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide

Size: px
Start display at page:

Download "0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide"

Transcription

1 0.56" 4 Digital Blue LED Panel Meter (rescalable) User s Guide Sure Electronics Inc. ME-SP037B_Ver1.0

2 0.56" 4 DIGITAL BLUE LED PANEL METER (RESCALABLE) USER S GUIDE Table of Contents Chapter 1. Overview Overview Quick Start Performance Specification Product Features... 4 Chapter 2. Preparations Install CP2102 Driver Install 037.rar Connections Power On Self Test Connect Panel Meter Board with Dupont Cable Connect with USB-RS232 Converter Connect USB-RS232 Converter with PC via USB Cable Chapter 3. Application Edit Start-up Display Rescale Value Output Chapter 4. Mechanical Drawing...17 Chapter 5. Appendix...18 Appendix 1 Letters-digits Table Chapter 6. Contact Us Sure Electronics Inc. ME-SP037B_Ver1.0_Page i

3 0.56" 4 Digital Blue LED Panel Meter (rescalable) NOTES: Product Version : Ver 1.0 Document Version : Ver 1.0 ME-SP037B_Ver1.0_Page ii Sure Electronics Inc

4 0.56" 4 DIGITAL BLUE LED PANEL METER (RESCALABLE) USER S GUIDE Chapter 1. Overview 1.1 Overview Thanks for using the panel meter by Sure Electronics. Please read this manual carefully prior to the installation of panel meter. As an innovative measuring device of the ME-SP03X series panel meter, been widely accepted by most of the buyers of Sure Electronics since its release, ME-SP037B is a high-efficient, flexible yet special digital voltmeter. Its A/D module is of a successive approximation type which makes the A/D conversion fast and accurate. Its self-adaptation ability to ambient brightness makes it an ideal choice in many applications. The most distinct feature of this panel meter is the flexibility that allows you to customize the display output based on inputted DC 0-10V. Users can rescale the displayed output values according to actual requirements. The range of display is any digit between FIGURE 1-1 OVERVIEW In industrial process control systems, parameters like weight, mass, temperature, humidity, velocity, speed, pressure, voltage, and current those describe the physical or chemical properties of a substance can be converted to industrial transfer standard-compliant DC 0-10V signal with the help of various pre-circuits. However, the actual chemical or physical values cannot be displayed intuitively. Now, the rescalability feature which makes ME-SP037B different from traditional panel meters helps engineers, technicians and pros eliminate their worries. Users can rescale panel meters of ME-SP037B with proprietary software to cater for applications that require direct industrial readings display instead of merely a voltage output ranging from 0-10V Sure Electronics Inc. ME-SP037B_Ver1.0_Page 1

5 0.56" 4 Digital Blue LED Panel Meter (rescalable) FIGURE 1-2 APPLICATION EXAMPLE Main Features a) Self adapted to ambient brightness, not dazzling in night time since the brightness can be adjusted automatically. b) Features Reverse Polarity Protection c) Flexible displaying and customizable output values d) Allowed to edit start-up displaying contents e) Large (0.56 /14.2mm) easy-to-read blue LED display f) Miniature housing g) Ideal for automotive, industrial applications h) -10 to +60 operating temperature range i) Over 90% components are SMT based, which are reliable and environment-friendly j) High-efficient DC-DC converter for powering, low operation temp rise, which is far below the temp rise of other competitive products k) UL and CE-certified compound AWG22 cables are used, low voltage drop. 1.2 Quick Start ME-SP037B_Ver1.0_Page Sure Electronics Inc

6 Overview Note: 1. As shown in the above schematic, the positive and negative leads of DC power supply are connected with VCC (+) and GND (-) respectively. The positive and negative leads of voltage to be measured are connected with VIN+ and VIN- of panel meter respectively. Panel meter will display redefined values. 2. GND and VIN- share the same ground in this panel meter. 3. NO MORE BURNED OUT METERS should you hook up the power leads incorrectly! 4. All diagrams and photos in this manual are for reference only. 1.3 Performance Specification Analog Input Min. Typ. Max. Units Scale Input Range: ME-SP037B 0-10 V Power Supply Requirements Supply Voltage: ME-SP037B V Supply Current VCC = 12V ) Full Sunlight ma Total Darkness ma Input Impedance VCC = 12V ) ME-SP037B MΩ Performance Responding Rate: s Accuracy minute warm up ) Sure Electronics Inc. ME-SP037B_Ver1.0_Page 3

7 0.56" 4 Digital Blue LED Panel Meter (rescalable) ME-SP037B % Display Display Type and Size ME-SP037B Over-range Indication Physical/Environmental 4 digit, 0.56 /14.2mm high LED 1 _ Operating Temperature Storage Temperature Humidity 0-85 %RH Note: 1. Power supply range is DC8.5-30V, do not exceed this range, otherwise panel meter will be burned. 2. Pay more attention to the positive and negative of VIN+ and VIN- when wiring. 1.4 Product Features The brightness of the diode varies with the change of ambient brightness and won t be too dazzling in night time. Adapted to the Ambient Brightness The brightness of diode will reach its topmost when the panel meter is in a room under direct sunlight exposure. The brightness of the diode is comparatively high when the panel meter is placed in a room, around which the environment is similar to dawn, nightfall or cloudy weather. ME-SP037B_Ver1.0_Page Sure Electronics Inc

8 Overview The brightness of the diode is the darkest when the panel meter is placed in an environment of almost no light from outside. Slowly Adjust the Brightness of Diode When the ambient environment of panel meter is shifted from light to dark or dark to light, the brightness of diode will be gradually changed and whole process will last for 4-6 seconds. The adjustment of brightness is smooth and it won t make people feel abrupt Sure Electronics Inc. ME-SP037B_Ver1.0_Page 5

9 0.56" 4 DIGITAL BLUE LED PANEL METER (RESCALABLE) USER S GUIDE Chapter 2. Preparations The following of this guide will detail the steps to rescale a panel meter, including preparations, test process and finally the application. Please follow the instructions carefully. Prior to the use of panel meter of ME-SP037B, please check the package contents carefully. The package of ME-SP037B contains the following: Item No Name Qty " 4 Digital Blue LED 10V Panel Meter(ME-SP037B) 1 2 USB-RS232 converter pin 2510 cable pin Dupont cable 1 5 USB cable 1 Note: Item 2, 4 and 5 are useful only when a panel meter is to be rescaled and users can rescale the panel meter many times. As for the software that is required for rescaling the panel meter, they are available and can be downloaded. Software Name Download Link CP2102 driver XP_S2K3.exe 037.rar Note: Please download CP2102 driver and 037.rar from the above link and install CP2102 driver first. 2.1 Install CP2102 Driver CP2102 driver helps establish the communication channel between panel meter (item 1) and users PC with the help of USB-RS232 converter (item 2), so it must be installed first. The full name of CP2102 driver downloaded is CP210x_VCP_Win2K_XP_S2K3.exe. Double-click it and the following will be displayed: ME-SP037B_Ver1.0_Page Sure Electronics Inc.

10 0.56" 4 Digital Blue LED Panel Meter (rescalable) Click Next > to proceed. Click I accept the terms of the license agreement and Next > to continue installation Sure Electronics Inc. ME-SP037B_Ver1.0_Page 7

11 Preparations Click Browse to specify the path that CP2102 driver is to be installed if necessary. Otherwise, click Next > to proceed. Click Install to start installation. It may take a few seconds for installation to complete and the following will pop up after the installation: ME-SP037B_Ver1.0_Page Sure Electronics Inc

12 0.56" 4 Digital Blue LED Panel Meter (rescalable) Click Finish to complete the installation of CP2102 driver. 2.2 Install 037.rar Unzip 037.rar after downloading from the link and you will find an exe file named ME-SP037.exe which you can directly run without any installation. Note: You may run ME-SP037.exe when you are sure that the connection of panel meter (item 1) and USB-RS232 converter (item 2) has been established. 2.3 Connections Power On Self Test Power On Self Test is a preliminary step to test the function of ME-SP037B. When you open the package of panel meter itself, you will see a white 4-pin header like shown below: Sure Electronics Inc. ME-SP037B_Ver1.0_Page 9

13 Preparations As clearly shown in the above snapshot, pins on the header are marked as VCC, GND, VIN+ and VIN- (from left to right), in which VCC and GND shall be connected with the positive (+) and negative (-)of DC power supply and VIN+ and VIN- shall be connected with voltage signal to be measured. ME-SP037B is pre-rescaled to display in a range from 0 to 1000, so if the voltage measured is DC 5V, ME-SP037B will display 500 on the panel meter. If ME-SP037B is able to display the voltage correctly, it means it can function well. Note: The allowed voltage of the DC power supply is DC V and DO pay more attention to the polarity when making connection with the DC power supply Connect Panel Meter Board with Dupont Cable To rescale ME-SP037B, you will need to: Remove the rear cover of the plastic housing. Detach the board with the plastic housing by unscrewing like shown below: The above is the snapshot of 4 holes after unscrewing. ME-SP037B_Ver1.0_Page Sure Electronics Inc

14 0.56" 4 Digital Blue LED Panel Meter (rescalable) Turn the board around and check the marks on the 7-pin header, which shall include the following: Pin Number Name 1 MCLR 2 +5V 3 GND 4 PGD 5 PGC 6 TX 7 RX Before connecting panel meter board and USB-RS232 converter, find your 6-pin Dupont cable that comes with the package of ME-SP037B. The construction of the Dupont cable is as follows: At the first glance, the cable looks peculiar since lead 3 is null and lead 4 and 6 are interconnected. All other leads are marked with different colors, so you can distinguish them when connecting with panel meter board. Make sure the following leads of Dupont cable DO connect with the following pins of panel meter board when you secure the connector of Dupont cable with the header: Lead 1 (Green) < > Pin RX (Pin 7) Lead 2 (Yellow) < > Pin TX (Pin 6) Lead 5 (Black) < > Pin GND (Pin 3) So when you finally establish the connection of Dupont cable and header of panel meter board, pin 1 of panel meter board is supposed to have left disconnected. Note: 1. To unscrew the board of ME-SP037B, you may use a 1.0mm screwdriver or preferably an Allen key. 2. If you cannot find the 7-pin header on the board, contact us immediately. Our contact info is attached in chapter Connect with USB-RS232 Converter Since we have stripped off the plastic sheath on other ends of leads 1, 2 and 5, the next would be to connect them with USB-RS232 converter. The following is an up-close of one of the black terminal blocks of USB-RS232 converter, in which pin GND, RXD and TXD are to be connected with lead 5,2 and 1 of Dupont cable respectively: Sure Electronics Inc. ME-SP037B_Ver1.0_Page 11

15 Preparations Black lead 5 (pin 3 of panel meter) < > Pin GND of converter Yellow lead 2 (pin 6 of panel meter) < > Pin RXD of converter Green lead 1 (pin 7 of panel meter) < >Pin TXD of converter Secure each connection by tightening the screws of the terminal block with screw driver. 2.5 Connect USB-RS232 Converter with PC via USB Cable As the final step before ME-SP037B can be rescaled, connect converter with your PC via USB cable (item 5) that is offered with ME-SP037B. ME-SP037B_Ver1.0_Page Sure Electronics Inc

16 0.56" 4 Digital Blue LED Panel Meter (rescalable) Remember to connect ME-SP037B with DC power supply after you have established the connection of panel meter board and PC Sure Electronics Inc. ME-SP037B_Ver1.0_Page 13

17 0.56" 4 DIGITAL BLUE LED PANEL METER (RESCALABLE) USER S GUIDE Chapter 3. Application 3.1 Edit Start-up Display You can re-edit the startup displaying contents according to your own discretion. Both upper case and lower case letters are allowed and the maximum number of letters or digitals is 8. This panel meter will dynamically display the contents you entered. It will start progress leftwards on an interval of 1 second and will go to normal working status after displaying for 5 seconds. Due to the performance limitation of 7-segment LED, some letters or digitals are displayed with special segment construction. You may refer to the appendix for the letters-digits table. The default display is SURESURE. 3.2 Rescale Value Output Initially, the display is specified at a range of and that display range can be modified according to the requirements of users. We offer tailored development software and two setting methods and either one of them requires only a simple setting. Run ME-SP037.exe after you unzip it from 037.rar when the connection of ME-SP037B and your PC is successfully established. Following is the snapshot after running: As shown above, the Com drop-down list allows you to select the COM port that panel meter communicates with PC installed with CP2102 driver. Normally, when you connect panel meter with your PC, a COM port will automatically be specified so that you can rescale your panel meter with software ME-SP037. You may verify the COM port number before selecting from the above drop-down list by the following steps: a) My Computer->Properties->Hardware->Device Manager->Ports (COM & LPT) b) Select a COM port from the above drop-down list and click OK to proceed. c) You may click HELP link to view the help document to know more info. The next page after you select the COM port actually tells us there are totally two different ways to rescale a ME-SP037B panel meter: ME-SP037B_Ver1.0_Page Sure Electronics Inc.

18 0.56" 4 Digital Blue LED Panel Meter(rescalable) As displayed in the above snapshot, the first is y=ax+b mode, a function that allows you to specify a and b so that voltage x measured will first be rescaled into y before it can be displayed on panel meter. So you will need to specify only a and b in the following page: Fill in the blanks of Ratio (a) and offset (b) and click OK when finished. e.g.: enter 0-10V DC, display Obviously we know that a=2.4 and b=0 Panel meter can readily be reconfigured to display target values after entering the above values. You may also click Prev to have a try on another mode to rescale panel meter ME-SP037B. The blank of Greeting allows you to specify the display on power-up. The default is SURESURE, which you can see it when the panel meter is powered. Note: 1. set coefficient a Range that users can enter: set offset b Range that user can enter: Sure Electronics Inc. ME-SP037B_Ver1.0_Page 15

19 Application 3. X is the initial display value, x relating to DC 0-10V is Though the above range is allowed, if y (value to be displayed) exceeds the range of after calculation, panel meter will display Err. The second mode: As in the page of step 2, click the second mode and next button to view the setting page like shown below: The second would be to fill in two sets of x and y-(x 1 y 1 ) & (x 2 y 2 ) so that a and b can be calculated. Following is an example: Y 1 =ax 1 +b Y 2 =ax 2 +b, in which x 1 =2, y 1 =30 (x 1 y 1 as the first set of start point and End point) x 2 =8,y 2 =90 (x 2 y 2 as the second set of start point and End point) So that a and b can be calculated easily as shown below: a =10, b=10 Hence, the function that ME-SP037B follows to rescale is Y=10x+10 Click OK when you complete the setting. You may try to measure voltage and compare the readings with the reading before rescaling. Note: Sure Electronics can also help you configure the panel meter if you expect to avoid the inconveniences of configuration. No tools or tailored software will be needed. ME-SP037B_Ver1.0_Page Sure Electronics Inc

20 0.56" 4 DIGITAL BLUE LED PANEL METER (RESCALABLE) USER S GUIDE Chapter 4. Mechanical Drawing FIGURE 4-1 MECHANICAL DRAWING Sure Electronics Inc. ME-SP037B_Ver1.0_Page 17

21

22 0.56" 4 DIGITAL BLUE LED PANEL METER (RESCALABLE) USER S GUIDE Chapter 5. Appendix Appendix 1 Letters-digits Table Due to the performance limitation of 7-segment display, some letters and digits are constructed with special segment architecture. The letters-digits table is as follows: ME-SP037B_Ver1.0_Page Sure Electronics Inc.

23 0.56" 4 DIGITAL BLUE LED PANEL METER (RESCALABLE) USER S GUIDE Chapter 6. Contact Us Sure Electronics Co., Ltd. 5F, Zone A, Qinhuai Technology Innovation Center DaMing Rd (ZIP:210022) Nanjing P.R.China Tel: (For technical questions only) (English service, from GMT1-10AM) Fax: Website: Sure Electronics Inc. ME-SP037B_Ver1.0_Page 19

0.56" Digital Red LED 30V Panel Meter(Auto brightness) User s Guide Sure Electronics Inc. ME-SP039_Ver1.0

0.56 Digital Red LED 30V Panel Meter(Auto brightness) User s Guide Sure Electronics Inc. ME-SP039_Ver1.0 0.56" 2 Digital Red LED 0V Panel Meter(Auto brightness) User s Guide 2004-2009 Sure Electronics Inc. ME-SP09_Ver1.0 Table of contents 0.56" 2 DIGITAL RED LED 0V Chapter1.Overview... 1 Chapter2.Performance

More information

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

MBUS 10 RS232 TO MBUS LEVEL CONVERTER Media and protocol converters MBUS 10 RS232 TO MBUS LEVEL CONVERTER RS232 to MBus level conversion Maximum 10 MBus slaves Baud Rate: 300 to 19200 bps RS232 MBus opto isolation Over-current and short-circuit

More information

Manual. Simrad IS80 Wind Instrument WI80. English

Manual. Simrad IS80 Wind Instrument WI80. English Manual Simrad IS80 Wind Instrument WI80 English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Manual Simrad IS80 Wind Instrument WI80 English Document no: 20223202 Revision:

More information

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any MRV366 Receiving Card Document Version: Document Number: V1.0.1 NS110100658 Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted

More information

EVENT INPUT/OUTPUT MODULE [PUME]

EVENT INPUT/OUTPUT MODULE [PUME] PUM Series Multi-loop module type Temperature controller DATA SHEET EVENT INPUT/OUTPUT MODULE [] is a digital input/output module used as an auxiliary input/output of control modules. Each module, 30mm

More information

Input Control. Input Voltage Range. Model. 2 Vin - 0.2~0.5V % SLD-DimTW V 2 2 Vin - 0.2~0.5V 5. 7 SLD-DimTW

Input Control. Input Voltage Range. Model. 2 Vin - 0.2~0.5V % SLD-DimTW V 2 2 Vin - 0.2~0.5V 5. 7 SLD-DimTW Model Input Voltage Range Input Control SLD-DimTW 8-48 V 1 2 Vin -.2~.5V 5 24 97% 8-48 V 2 2 Vin -.2~.5V 5 24 97% 7 SLD-DimTW -2175 Voltage Range Please refer model table Input Current 5.1A max (per channel)

More information

High intensity led illuminator ILED42A FEATURES: DESCRIPTION: ELECTRICAL CHARACTERISTICS:

High intensity led illuminator ILED42A FEATURES: DESCRIPTION: ELECTRICAL CHARACTERISTICS: High intensity led illuminator May 2010 Rev 0.3 ILED42A FEATURES: High luminous flux Low cost Fully protected Wide input voltage range Available with different led colours and lenses DESCRIPTION: The IDP

More information

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

FTS84/85  Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]

More information

DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES

DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES DIGITAL PANEL METER DISPLAY FOR 15mm MOSAIC - LPDSA SERIES APPLICATION LPD04SA-15B-R (29.9 59.9 172mm) This product is digital display for system which is most suitable for display of various data of main

More information

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630) Vorne Industries 87/719 Analog Input Module User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Introduction... 1.1 Accessing Wiring Connections

More information

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3 MoTeC MDD User Manual Contents Introduction... 1 Display...1 Mounting...1 Firmware Version...2 ADL Operation... 3 1. Full ADL Display...4 2. Gain Loss Layout for ADL...6 3. Large Numeric Layout for ADL...8

More information

Manual. Simrad IS80 Heading Repeater HR80. English

Manual. Simrad IS80 Heading Repeater HR80. English Manual Simrad IS80 Heading Repeater HR80 English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Manual Simrad IS80 Heading Repeater HR80 English Document no: 20223194 Revision:

More information

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual IRIG-B PTP Clock Converter Output Module Hardware Installation Manual Kyland Technology Co., LTD. Publication Date: May 2012 Version: V1.2 Customer Service Hotline: (+8610) 88796676 FAX: (+8610) 88796678

More information

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards BREAK-TW-V.4/4, BREAK--V.4/4 BOX DIN RACK IP56 Optoconverters are designed to transfer videosignal and or data. I FM modulation I AGC optical loss I Universal for MM and SM fibres I Up to 3 independent

More information

Electronic converter for level transmitters MT03L Instructions manual

Electronic converter for level transmitters MT03L Instructions manual Electronic converter for level transmitters MT03L Instructions manual R-MI-MT03L Rev.: 1 English version PREFACE Thank you for choosing the MT03L converter from MT03 series of Tecfluid S.A. This instruction

More information

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing. Product Data Electrical Data SST (Transmitter) SSR (Receiver) Supply voltage 18 30 V dc Max. Voltage ripple 15 % (within supply range) Current consumption 100 ma (RMS) 75 ma Digital - 100 ma Max. outputs

More information

Step What to do Expected result What to do if test fails Component tested 1 Visual inspection. Board is accurately assembled

Step What to do Expected result What to do if test fails Component tested 1 Visual inspection. Board is accurately assembled Fox Delta Amateur Radio Projects & Kits AAZ-0914A 50MHZ Antenna Analyzer Testing Guide by Tony / I2TZK SWR Analyzer 4 steps for a quick test Step What to do Expected result What to do if test fails Component

More information

Table of contents 1. INTRODUCTION GENERAL CONTENTS OF PACKAGE GENERAL USE OF THE EQUFLOW 6100 D/A CONVERTER STORAGE..

Table of contents 1. INTRODUCTION GENERAL CONTENTS OF PACKAGE GENERAL USE OF THE EQUFLOW 6100 D/A CONVERTER STORAGE.. Installation instructions and user s guide Equflow 6100 D/A Converter Please read this manual carefully before installation and use of the converter. 6100 D/A Converter Type: 6100DACONDC03 Despite effort

More information

VIDEO ALARM VERIFICATION UNIT VIVER

VIDEO ALARM VERIFICATION UNIT VIVER VIDEO ALARM VERIFICATION UNIT VIVER viver_en 09/08 The VIVER module provides remote video alarm verification, based on image sequences transmitted from cameras installed in the protected facility. The

More information

DM1624, DM1612, DM812

DM1624, DM1612, DM812 Installation Guide Hardware and Software DM Series Digital Processors models DM1624, DM1612, DM812 LECTROSONICS, INC. 1 Installation Specific Information Only This guide covers only installation related

More information

RS-232 to Multi-Mode Fiber Optic Media Converter

RS-232 to Multi-Mode Fiber Optic Media Converter RS-232 to Multi-Mode Fiber Optic Media Converter (ID-SC0F11-S1) User s Manual 04-0780A - 1 - Introduction This converter converts RS 232 signals to fiber for data transmission and communication Features

More information

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any Receiving Card MRV328 Document Version: Document Number: V1.0.0 NS110100409 Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted

More information

DALI TOUCHPANEL BASIC TW. Operating and control unit

DALI TOUCHPANEL BASIC TW. Operating and control unit BASIC Operating and control unit Product description Capacitive Touchpanel High-quality appearance with real glass display Multiple control modules are possible in a system Power supply via line Double

More information

Micro-DCI 53ML5100 Manual Loader

Micro-DCI 53ML5100 Manual Loader Micro-DCI 53ML5100 Manual Loader Two process variable inputs Two manually controlled current outputs Multiple Display Formats: Dual Channel Manual Loader, Single Channel Manual Loader, Manual Loader with

More information

Data Acquisition Using LabVIEW

Data Acquisition Using LabVIEW Experiment-0 Data Acquisition Using LabVIEW Introduction The objectives of this experiment are to become acquainted with using computer-conrolled instrumentation for data acquisition. LabVIEW, a program

More information

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Installation. SAPTF33xx-1xx in the Network. Standard Configuration SAPTF33xx-1xx in the Network Standard Configuration One Unit A device (SAPTF33xx-100) and one device () are required for the standard configuration. The Unit A device is connected to the while the device

More information

Model: S-1071H 7" Broadcast On-camera 3GSDI&HDMI LCD Monitor. User Manual. Please read this User Manual throughout before using.

Model: S-1071H 7 Broadcast On-camera 3GSDI&HDMI LCD Monitor. User Manual. Please read this User Manual throughout before using. Model: S-1071H 7" Broadcast On-camera 3GSDI&HDMI LCD Monitor User Manual Please read this User Manual throughout before using. Preface Congratulations on your purchase of this product. Please read this

More information

Displays. 4.3 Digital TFT-LCD Module. 1. General Descriptions

Displays. 4.3 Digital TFT-LCD Module. 1. General Descriptions 4.3 Digital TFTLCD Module KT. General Descriptions. Features 4.3 Digital TFT LCD Ultra Compact NTSC/PAL/SECAM Video Auto Switch Single Operation Voltage +V CVBS / Analog RGB (PC Mode) Signal nput All Functions

More information

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1 Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1 Contents 1) Grid-Tie Installation Block Diagram... 3 2) Installation Steps.... 4 2.1) Initial Setup.... 4 2.1.1)

More information

SERCOS TSX CSY 84 Module V

SERCOS TSX CSY 84 Module V SERCOS TSX CSY 84 Module V At a Glance Aim of this Part What's in this part? This part presents the SERCOS TSX CSY 84 module, its operating features and its installation. This Part contains the following

More information

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual 100Base-FX Multi-mode to 100Base-FX Single Mode Converter NXF-708 Series User s Manual COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

LONWORKS Fibre Optic Converter

LONWORKS Fibre Optic Converter LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring

More information

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

FTS84/85   Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process FTS84/8 Feature Application Field Capable of temperature compensation and linear adjustment Double line character : air velocity & temperature Switch for physical quantity:[m/s] [ft/s] [km/h] [mph] [knot]

More information

CI-218 / CI-303 / CI430

CI-218 / CI-303 / CI430 CI-218 / CI-303 / CI430 Network Camera User Manual English AREC Inc. All Rights Reserved 2017. l www.arec.com All information contained in this document is Proprietary Table of Contents 1. Overview 1.1

More information

Ethernet to VGA over IP Converter

Ethernet to VGA over IP Converter Ethernet to VGA over IP Converter Product ID: IPUSB2VGA The IPUSB2VGA Ethernet to VGA over IP Converter offers versatile VGA video distribution by extending a VGA signal over Ethernet cable, for transmission

More information

TeamWork Kits Installation Guide

TeamWork Kits Installation Guide TX 0 RX COM +5V APARATUS US TeamWork Kits Installation Guide TeamWork 400 and TeamWork 600 Kits The TeamWork 400 and TeamWork 600 kits consist of an HDMI switcher, system controller, Cable Cubby, and cables

More information

Configuration Vestas VMP3500

Configuration Vestas VMP3500 Configuration Vestas VMP3500 1. Table of contents 1. Table of contents... 2 2. Introduction... 3 3. Vestas turbines (RCS)... 4 3.1. VMP 3500 controller... 4 3.2. Communication with the CT3230 current loop

More information

Active FCB-EV-HD-SDI INTERFACE BOARD

Active FCB-EV-HD-SDI INTERFACE BOARD Active FCB-EV-HD-SDI INTERFACE BOARD HD-SDI digital interface for the Sony FCB-EV series cameras (FCB-EV7520A/7500/7310/7300/7100/5500/5300) 1080p/1080i/720p high definition video Built in test pattern

More information

SY-HDBT-SLIM-100S Extender Set

SY-HDBT-SLIM-100S Extender Set Installation Guide SY-HDBT-SLIM-100S Extender Set with HDMI, Ethernet, IR, RS232 and Power over 100m of cat6 Cable HDBaseT HDMI Extenders SY Electronics Ltd, Unit 7, Worrall Street, Salford, Greater Manchester,

More information

PicoScope 4000 Automotive PC Oscilloscopes

PicoScope 4000 Automotive PC Oscilloscopes PicoScope 4000 Automotive PC Oscilloscopes User's Manual ps4000a.en-1 Copyright 2008 Pico Technology Ltd. All rights reserved. Contents I Contents 1 Introduction...1 1 Overview...1...1 2 Minimum PC requirements...2

More information

medlab One Channel ECG OEM Module EG 01000

medlab One Channel ECG OEM Module EG 01000 medlab One Channel ECG OEM Module EG 01000 Technical Manual Copyright Medlab 2012 Version 2.4 11.06.2012 1 Version 2.4 11.06.2012 Revision: 2.0 Completely revised the document 03.10.2007 2.1 Corrected

More information

Overview. Shipped in the Venue Vizion Package: Simplified Integration Process. Installation consists of 6 easy steps:

Overview. Shipped in the Venue Vizion Package: Simplified Integration Process. Installation consists of 6 easy steps: Overview Shipped in the Venue Vizion Package: Four two-channel QMOD Encoder-Modulators Each unit can accept up to 2 inputs, providing up to 8 channels in the system. One ICE-HE-DXL Display Control Center

More information

SY-MS121 SY-MS121-AP

SY-MS121 SY-MS121-AP Installation Guide SY-MS121 and SY-MS121-AP Presentation Switcher with Multi-Format Inputs and Outputs 4 HDMI, 4 VGA, 1 Component video, 2 Composite video & 1 S-video inputs Simultaneous HDMI, VGA & HDBaseT

More information

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope Quick Start RSHS1000 Series Handheld Digital Oscilloscope General Safety Summary Carefully read the following safety precautions to avoid personal injury and prevent damage to the instrument or any products

More information

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02 Owner s Manual multiswitch 1.41 Firmware-Version 1.06 OS- Version 1.02 The information contained in this manual is subject to change without prior notice. All rights reserved. Current as of: Juli 19 th

More information

Mini Gateway USB for ModFLEX Wireless Networks

Mini Gateway USB for ModFLEX Wireless Networks Mini Gateway USB for ModFLEX Wireless Networks FEATURES Compatible with all modules in the ModFLEX family. USB device interface & power Small package size: 2.3 x 4.9 External high performance antenna.

More information

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES EN K20RTD 2 WIRE - LOOP POWERED TRANSMITTER FOR PT00 AND NI00 PROBES General Description The K20RTD instrument converts a temperature signal read by a PT00 (EN 60 75) or NI00 probe with connection by 2,

More information

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE NorthStar brand SERIES HD35R Heavy Duty Encoder Key Features Phased Array Sensor for Reliable Signal Output Rugged Design with Wide-Spaced Oversized Bearings Unbreakable Code Disc up to 5000PPR Improved

More information

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN STANDARD FEATURES ±1,999-count display span ±200 mv to ±200 Vdc ranges True-differential input with 80 db CMR 3-wire ratio

More information

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Advantys STB Advantys STB Input Module DATA SHEET Description The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Features

More information

DC-105 Quick Installation Guide

DC-105 Quick Installation Guide DC-105 Quick Installation Guide PACKAGE CONTENTS 2 POWER ON 2 CONNECT TO A DVB-T RECEIVER 3 ADJUST THE FOCUS OF THE LENS 3 CONNECT TO A CVBS MONITOR 4 MIC-IN 4 USB UART DONGLE 5 MONITOR BOOT MESSAGES 7

More information

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling! Medium Speed Network Terminal Box Supports dynamic measurement at medium-speed synchronous sampling! Decentralized arrangement and synchronous sampling of all channels. Medium Speed Network Terminal Box

More information

Part No./ 型号 : RGB-Controller-101

Part No./ 型号 : RGB-Controller-101 Instructions: Thank you for using RGB-Controller-101 of our company. Before installation, please read this manual carefully to ensure fully understand and proper use in order to avoid unnecessary damages

More information

Fibre Optic Modem ODW-622

Fibre Optic Modem ODW-622 Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces.

More information

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9110 QUICK START GUIDE Thank you for purchasing a TSI AeroTrak Model 9110 Portable Airborne Particle Counter (particle counter). This guide will help you

More information

V6118 EM MICROELECTRONIC - MARIN SA. 2, 4 and 8 Mutiplex LCD Driver

V6118 EM MICROELECTRONIC - MARIN SA. 2, 4 and 8 Mutiplex LCD Driver EM MICROELECTRONIC - MARIN SA 2, 4 and 8 Mutiplex LCD Driver Description The is a universal low multiplex LCD driver. The version 2 drives two ways multiplex (two blackplanes) LCD, the version 4, four

More information

DATA SHEET. HDMI Active Optical Cable HDFC-200D. Contents

DATA SHEET. HDMI Active Optical Cable HDFC-200D. Contents DATA SHEET HDMI Active Optical Cable HDFC-200D Contents Description Features Applications Absolute Maximum Ratings Recommended Operating Conditions Physical Characteristics Pin Description Connection Diagram

More information

MP-III Writer User Manual MANUAL REVISION HISTORY Version Date Description V1.0 Mar First Issue SONiX TECHNOLOGY CO., LTD. Page 2 Version 1.0

MP-III Writer User Manual MANUAL REVISION HISTORY Version Date Description V1.0 Mar First Issue SONiX TECHNOLOGY CO., LTD. Page 2 Version 1.0 MP-III Writer User Manual SONiX 8-Bit MCU MP-III Writer User Manual V1.0 SONIX reserves the right to make change without further notice to any products herein to improve reliability, function or design.

More information

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Z-D-IN. RS485 Modbus Module 5 Digital Inputs S SENECA Z-PC Line EN Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - Modbus connection rules - DIP-switches Settings -

More information

Operating Instructions

Operating Instructions CNTX Contrast sensor Operating Instructions CAUTIONS AND WARNINGS SET-UP DISTANCE ADJUSTMENT: As a general rule, the sensor should be fixed at a 15 to 20 angle from directly perpendicular to the target

More information

Input Control. Input Voltage Range. Model. 2 Vin - 0.2~0.5V % SLD-DimTW V 2 2 Vin - 0.2~0.5V 5. 7 SLD-DimTW

Input Control. Input Voltage Range. Model. 2 Vin - 0.2~0.5V % SLD-DimTW V 2 2 Vin - 0.2~0.5V 5. 7 SLD-DimTW Model Input Voltage Range Input Control 8-48 V 1 2 Vin - 0.2~0.5V 5 240 97% 2 8-48 V 2 2 Vin - 0.2~0.5V 5 240 97% 7-201705 Voltage Range Please refer model table Input Current 5.1A max (per channel) Control

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled CE CPS 12/15 W ED Driver for AC and DC power supplies Product description ED Driver for mains operation with integrated Simple CORRIDOR FUCTIO (CF) For use in central battery systems For luminaire installation

More information

USER'S MANUAL. Getting started with ALEXAN ATMEL AT89C2051/AT89C4051 Training Module - 1

USER'S MANUAL. Getting started with ALEXAN ATMEL AT89C2051/AT89C4051 Training Module - 1 USER'S MANUAL Getting started with ALEXAN ATMEL AT89C05/AT89C405 Training Module - Version.0 Copyright 006 Ace Electronic Technology Inc. All Rights Reserved Alexan 05/405 TM- v..0 Page of 7 About This

More information

Preventing Fieldbus Physical Layer Problems

Preventing Fieldbus Physical Layer Problems Preventing Fieldbus Physical Layer Problems 1 Introduction Foundation Fieldbus is highly reliable when correctly installed and maintained. The key is in knowing what must be done to start with and to maintain

More information

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Panel cutout required: 1.772 x 3.622 (45mm x 92mm) 1.76 (45mm) 2.45 (62mm) 3.20 (81mm) 3.60 (91mm) 0.59 (15mm) Special Features NEMA4X, IP65 Front Bezel Meter with Relays Option RELAY2 RELAY1 24V OUT POWER 4 3 2 1 6 5 2 1 2 1 NO NC COM NO NC COM RTD TC P P RTD 3 4 1 2 5 TC 6 SWITCH Rear View Gasket APM765 Panel Meter Description

More information

Installation Guide AT-HDR-EX-70-2PS

Installation Guide AT-HDR-EX-70-2PS 4K HDR HDMI Over TX/RX Kit The Atlona is an transmitter/receiver kit for high dynamic range (HDR) formats. The kit is HDCP 2.2 compliant and supports 4K/UHD video @ 60 Hz with 4:4:4 chroma sampling, as

More information

PicoScope 2000 Series PC Oscilloscopes

PicoScope 2000 Series PC Oscilloscopes PicoScope 2000 Series PC Oscilloscopes User guide I PicoScope 2000 Series User Guide Table of Contents 1 Introduction...2...2 1 Overview...2 2 Safety symbols...3 3 Safety warning...3 4 FCC notice 5 CE

More information

TL8651 3G/HD-SDI Output Video Transceiver. TL8651 Features. Block Diagram TL8651 3G/HD-SDI. 1080p p50

TL8651 3G/HD-SDI Output Video Transceiver. TL8651 Features. Block Diagram TL8651 3G/HD-SDI. 1080p p50 Thunder Link is a family of small form factor modules for formatting and converting generic digital video streams to standard compliant formats. Different interface standards are supported from the transmitter

More information

Telesto Private Wire Modem Manual

Telesto Private Wire Modem Manual Telesto Private Wire Modem Manual Telesto Private Wire Modem Manual Revision History Filenames are: G:\Company\Manuals &graphics\manuals \ReferenceManual\Components\Telesto_modem\Private Wire\Remote\RevA\CompleteManual\TelestoPwModemCover.lwp

More information

SDI-MP1010-GM-60P-M-RA 3G/HD-SDI Output Video Transceiver. SDI-MP1010-GM-60P-M-RA Features. Block Diagram SDI-MP1010-GM-60P-M-RA.

SDI-MP1010-GM-60P-M-RA 3G/HD-SDI Output Video Transceiver. SDI-MP1010-GM-60P-M-RA Features. Block Diagram SDI-MP1010-GM-60P-M-RA. This is a family of small form factor modules for formatting and converting generic digital video streams to standard compliant formats. Different interface standards are supported from the transmitter

More information

PRO-ScalerHD2V HDMI to VGA & Audio Scaler Converter. User s Guide. Made in Taiwan

PRO-ScalerHD2V HDMI to VGA & Audio Scaler Converter. User s Guide. Made in Taiwan PRO-ScalerHD2V HDMI to VGA & Audio Scaler Converter User s Guide Made in Taiwan Congratulations for owning a gofanco product. Our products aim to meet all your connectivity needs wherever you go. Have

More information

TeamWork Installation Guide

TeamWork Installation Guide C G G 00-0V/ A MAX TX RX +V APARATUS US 0 TeamWork Installation Guide TeamWork TeamWork is a fully customizable collaboration system comprised of an switcher, Show Me cables, a control processor, and a

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled E 15 W CE CPS ED Driver for AC and DC power supplies Product description ED Driver for mains operation with integrated Simple CORRIDOR FUCTIO (CF) For use in central battery systems For luminaire installation

More information

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any Document Version: Document Number: V1.1.0 NS110100423 A8s Receiving Card Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted

More information

TV Character Generator

TV Character Generator TV Character Generator TV CHARACTER GENERATOR There are many ways to show the results of a microcontroller process in a visual manner, ranging from very simple and cheap, such as lighting an LED, to much

More information

RF4432 wireless transceiver module

RF4432 wireless transceiver module RF4432 wireless transceiver module 1. Description RF4432 adopts Silicon Lab Si4432 RF chip, which is a highly integrated wireless ISM band transceiver. The features of high sensitivity (-121 dbm), +20

More information

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor

User Manual MODEL: KK1500-TR. Touch Display LCD Monitor. Installation Guide. 15 Resistive Touch LCD Monitor Touch Display LCD Monitor User Manual Installation Guide 15 Resistive Touch LCD Monitor MODEL: KK1500-TR i-tech Company LLC TOLL FREE: (888) 483-2418 EMAIL: info@itechlcd.com WEB: www.itechlcd.com User

More information

User Manual rev: Made in Taiwan

User Manual rev: Made in Taiwan CV-500S HDMI to Component/CVBS & Audio Scaler Converter User Manual rev: 131218 Made in Taiwan The CV-500S HDMI to Component/CVBS & Audio Scaler Converter has been tested for conformance to safety regulations

More information

Item Symbol Absolute Maximum Rating Unit Remarks

Item Symbol Absolute Maximum Rating Unit Remarks 5.6 TFT LCD asi LCD Color Module The AND-TFT-56LP is a compact full color TFT LCD module, that is suitable for portable products, industrial products, hand-held products, security products, instrument

More information

ET-REMOTE DISTANCE. Manual of ET-REMOTE DISTANCE

ET-REMOTE DISTANCE. Manual of ET-REMOTE DISTANCE ET-REMOTE DISTANCE ET-REMOTE DISTANCE is Distance Measurement Module by Ultrasonic Waves; it consists of 2 important parts. Firstly, it is the part of Board Ultrasonic (HC-SR04) that includes sender and

More information

Solis Export Power Manager

Solis Export Power Manager Solis Export Power Manager Installation and Operation Manual Ningbo Ginlong Technologies Co., Ltd. No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo, Zhejiang, 3572, P.R.China Tel: +86 (0)574

More information

LONWORKS Fibre Optic Router

LONWORKS Fibre Optic Router LONWORKS Fiber Optic Router LRW-112 and LRW-112/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-112 router offers an easy way to extend the distance between LONWORKS

More information

Fibre optic router for TP/FT-10 LRW-112PP

Fibre optic router for TP/FT-10 LRW-112PP Fibre optic router for TP/FT-10 LRW-112PP Lo n Wo r k s to fibre optic link, point-to-point applications The LRW-112PP router offers an easy way to extend the distance between LONWORKS 78 kbit/s TP/FT

More information

TL7650/TL7651/TL7652 Dual HD-SDI / DVI(HDMI) Output Video Transceiver. TL765x Series Features. Block Diagram TL7650. Dual HD-SDI + DVI(HDMI)

TL7650/TL7651/TL7652 Dual HD-SDI / DVI(HDMI) Output Video Transceiver. TL765x Series Features. Block Diagram TL7650. Dual HD-SDI + DVI(HDMI) Thunder Link is a family of small form factor modules for formatting and converting generic digital video streams to standard compliant formats. Different interface standards are supported from the transmitter

More information

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times Color Mark Color Mark Feature Outstanding color matching accuracy - RGB light emitting diodes and 12-bit resolution - 2 detection modes (color only / color + intensity) - -step sensitivity adjustment for

More information

User Manual. HDBaseT Wallplate Transmitter over Cat6/6A. Front View Panduit Dr, Tinley Park, IL (708)

User Manual. HDBaseT Wallplate Transmitter over Cat6/6A. Front View Panduit Dr, Tinley Park, IL (708) User Manual HDBaseT Wallplate Transmitter over Cat6/6A Front View 18900 Panduit Dr, Tinley Park, IL 60487 (708) 532-1800 Back View TABLE OF CONTENTS Introduction 2 Features 3 Package Contents 3 Technical

More information

Galaxias. Flex LED display. User Manual

Galaxias. Flex LED display. User Manual Galaxias Flex LED display User Manual Conterts Specifications 2 Dimension 3 Attentions 4 Introduction 5 Transportation 6 Installation 7 Maintenance 10 Troubleshooting 11 01 Specifications on Galaxias Series

More information

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O Characteristics motion servo drive - Lexium 23 - single phase 200...255 V - 1 kw - I/O Main Range of product Product or component type Device short name Complementary Format of the drive Network number

More information

Serial Flash Programmer. S550-SFWv3 FA Mode. Operation Manual. Sunny Giken Inc.

Serial Flash Programmer. S550-SFWv3 FA Mode. Operation Manual. Sunny Giken Inc. Serial Flash Programmer S550-SFWv3 FA Mode Operation Manual Sunny Giken Inc. Serial Flash Programmer S550-SFWv3 FA Mode The contents of this manual may be revised without notice. We, Sunny Giken Inc. shall

More information

Marshall Electronics. Pro A/V Communications VMV-402-SH. 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display. User Manual.

Marshall Electronics. Pro A/V Communications VMV-402-SH. 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display. User Manual. Marshall Electronics Pro A/V Communications VMV-402-SH 3G/HD/SD-SDI Quad-viewer/Switcher with Audio Meter Display User Manual Table of Contents 1. Introduction... 3 2. Features... 3 3. Package Contents...

More information

apple Service Source Apple Cinema HD Display 23" LCD (ADC) 11 April Apple Computer, Inc. All rights reserved.

apple Service Source Apple Cinema HD Display 23 LCD (ADC) 11 April Apple Computer, Inc. All rights reserved. apple Service Source Apple Cinema HD Display 23" LCD (ADC) 11 April 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Take Apart Apple Cinema HD Display 23" LCD (ADC) 2003 Apple

More information

ASP-FIBRS1 User Manual

ASP-FIBRS1 User Manual ASP-FIBRS1 HDMI Single Fiber Extender with Serial and IR User Manual Manual Number: 100823 Safety and Notice The ASP-FIBRS1 HDMI Extender over 1 fiber with serial and IR have been tested for conformance

More information

ODW-621. RS-232 Point-to-point applications

ODW-621. RS-232 Point-to-point applications Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to

More information

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4

Contents: 1 LANsmart Pro Main Unit 4 Remote Unit: ID1, ID2, ID3, ID4 LANsmart Pro user manual Introduction LANsmart Pro is a hand-held, multifunction Cable Map Tester and Cable Length Meter. It has an integrated Analog and Digital Tone Generator, Port Finder, and Quick

More information

Evaluation Board for CS4954/55

Evaluation Board for CS4954/55 Evaluation Board for CS4954/55 Features l Demonstrates recommended layout and grounding practices l Supports both parallel and serial digital video input l On-board test pattern generation l Supports NTSC/PAL

More information

TALOS ITR-T250. TALOS ITR-T250 Driver Setup Guide (V1.0) on the disk sent with the printer. Follow the steps (see the picture):

TALOS ITR-T250. TALOS ITR-T250 Driver Setup Guide (V1.0)   on the disk sent with the printer. Follow the steps (see the picture): TALOS ITR-T250 Driver Setup Guide (V1.0) Run the on the disk sent with the printer. Follow the steps (see the picture): Then click Next (see the following picture). 1 Choose I accept the agreement, (see

More information

P-2 Installing the monitor (continued) Carry out as necessary

P-2 Installing the monitor (continued) Carry out as necessary P-2 Installing the monitor (continued) Carry out as necessary Using the monitor without the bezel MDT552S satisfies the UL requirements as long as it is used with the bezel attached. When using the monitor

More information

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE MANUAL PART NUMBER: 400-0430-001 1-IN 1-OUT LINE DRIVER WITH UALIZATION + AUDIO USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL...2 GUIDELINES FOR RACK-MOUNTING...2 INSTALLATION...2

More information

Instructions for DataMark PDF Temperature Logger

Instructions for DataMark PDF Temperature Logger Instructions for DataMark PDF Temperature Logger DataMark provides a convenient way to obtain high accuracy temperature data in transit. The unit is a self contained temperature logger that plugs directly

More information