Smart Com Remote Diagnostics Manual - Rev 6

Size: px
Start display at page:

Download "Smart Com Remote Diagnostics Manual - Rev 6"

Transcription

1 Smart Com Remote Diagnostics Manual - Rev 6 Chapter 1: Overview Varis' Remote Diagnostics (RD) allows you to remotely troubleshoot your Smart Com communication system via the mine's own local area network (LAN). This version of the software supports remote diagnostics for Smart Com 150/150IS, Smart Com 450/450IS and Smart Com Ethernet systems. Regardless of the size of the system, Remote Diagnostics can improve uptime and provide confidence in the system. Smart Com 150/150IS: All Smart Com 150 and 150IS amplifiers periodically send RD data back to the DRX located in the Base Station. software. Mine personnel can then simply point their web browser to the RD web server in order to view the status of the system. Smart Com 450/450IS: Smart Com 450 and 450IS amplifiers are polled using the RD web server software through a serial connection between the server and 450 Head End. Currently, amplifiers must be added to the system via the web interface to be polled. Future versions will automatically detect amplifiers installed along the leaky feeder network. Smart Com Ethernet: Smart Com Remote Diagnostics is also capable of showing CMTS (Cable Modem Termination System) and cable modem diagnostics for Smart Com Ethernet systems. The RD web server will periodically poll Ethernet devices using SNMP to retrieve diagnostic information. Key Benefits: Immediate notification of system faults ( ed alarms). The ability to pinpoint faults so that technicians can be dispatched directly to the problem area. System status can be viewed from any computer on the mine's LAN. Reduced need for expensive equipment to troubleshoot the Smart Com 150/150IS, Smart Com 450/450IS and Smart Com Ethernet systems. Chapter 2: Software 1 Requirements It's recommended that the Remote Diagnostic software be installed and run on Varis server hardware. Please contact us for more information. If alternate hardware must be used, the recommended system specifications are: Pentium 4 or equivalent processor. 2 GB of RAM. Windows XP, Windows Server 2003/2008. C:\Workspace\...\help\help_en.xml page 1 of 56

2 500 MB free disk space. Ethernet adapter. Serial port (only required for Smart Com 450/450IS systems) MS Internet Explorer 6+ (Javascript enabled). Administrator access to PC. 2 Installation The RD web server must be installed on a computer connected to the mine's LAN and must have a static IP address. Ask your IT Administrator for help in setting this up. 1. To install, run the "rdweb-setup-x.x.x.exe" file located on the distribution CD and follow the installation wizard. It is recommended that you use the default file locations. 2. The HTTP Port selection screen allows you to select which port the web server will run on. The default is port 80, but if you already have a web server running on port 80 (such as IIS), then you can chose an alternate port such as Please note: if you chose a port other than the default of 80, then you will have to specify the port number in the web address URL. For example, to access the main Remote Diagnostics web page, you would use the following URL: where ipaddress is the IP address of the web server PC. 3. The Site Name input screen allows you to enter the name of the site where the system is installed (i.e., mine name). 4. The System Type screen is used to select the type of Remote Diagnostics system; either Smart Com 150, Smart Com 450, or both Smart Com 150 and 450. This can be changed through the Administration interface later if incorrectly specified here. See Viewing Amplifier and Ethernet Data for more information. Note: It is important that the web server PC remain running at all times. This will ensure that all diagnostic data is displayed by the Remote Diagnostic web server. Chapter 3: Smart Com 150/150IS Hardware 1 Overview C:\Workspace\...\help\help_en.xml page 2 of 56

3 1. "Alarm" Relay Contacts: Contacts close when an alarm condition is detected ("No Alarm" contacts open). 2. "No Alarm" Relay Contacts: Contacts close when there is no alarm condition present ("Alarm" contacts open). 3. RS232 Detect LED: LED will energize when a diagnostic packet is received from a MultiCOM amplifier through the RS232 connector (P6). 4. Carrier Detect (CD) LED: Led will energize when an incoming Varis diagnostic packet is detected at the Rx Connector (P3). 5. Reset P.B.: Performs a board software reset. 6. Power LED: LED energizes when power (+12 Vdc) is applied to the board. 7. Power Connector: Power supply connector (+12 Vdc). 8. Fuse: 500 ma, 250V, Fast Acting, 2AG (P/N HXP). 9. Rx Connector: 50 ohm BNC connector. Connects to receive port 16 of RNG-RF RS232 Input Connector: Connect leads from supplied DB9 connector. DB9 plug connects to MultiCOM diagnostic receiver. Proper polarity must be observed when connecting to the DRX. 11. RJ-45 Connector: Connects the DRX to the mine's LAN (Cat 5 cable). 12. Tx Connector: 50 ohm BNC connector. Connects to transmit port 16 of RNG-RF16. Please note that some units may be fitted with an external Low Pass filter. This filter must remain in place for proper operation. 13. Tx Level Adjust: Varying the potentiometer will vary the output signal strength of the on-board C:\Workspace\...\help\help_en.xml page 3 of 56

4 downstream pilot (154.5 MHz Channel List 2.0, MHz Channel List 3.0, MHz Channel List 3.1) between +3 and +14 dbm (max). The R48 potentiometer replaces R29 on Revision C DRX boards. 14. Tx On LED: LED will energize when the downstream pilot is on. 15. Downstream Pilot Jumper: The downstream pilot can be controlled locally or remotely using this three position jumper. See Downstream Pilot for more information. 16. IP Default Jumper: Used to restore default network settings. See DRX Network Reset for more information. 1.1 DRX Features Status Relays The diagnostic receiver provides two relay contacts to monitor the health of your Smart Com 150/150IS and Smart Com Ethernet system (See Hardware Overview). These contacts can be connected to external devices to provide visual and/or audible indications of the systems state Downstream Pilot The diagnostic receiver has an on-board downstream pilot (154.5 MHz Channel List 2.0, MHz Channel List 3.0, MHz Channel List 3.1) that can operate in local or remote mode depending on the position of the Downstream Pilot jumper (JU3). The downstream pilot's signal strength can be adjusted between 3 and 14 dbm by varying R48 (R29 on Rev C boards). See Downstream Pilot Tuning for more information. A 50 ohm BNC-BNC coaxial cable must be connected between the Tx connector (P2) and transmit port 16 of RNG-RF16. Please note that some units may be fitted with an external Low Pass filter. This filter must remain in place for proper operation. Local Mode: In order to operate the downstream pilot locally, the Downstream Pilot jumper (JU3) must be set to the On or Off positions. Remote Mode: 1. Set the Downstream Pilot jumper (JU3) to the Auto position. 2. Connect to the RD web server by typing the IP address of the device on which the web server is running (i.e., 3. Login as an Administrator (See User Access). 4. Open the administration interface by clicking on the Admin link in the upper right-hand corner of the page. 5. Next, click on Downstream Pilot from the administration menu. C:\Workspace\...\help\help_en.xml page 4 of 56

5 6. The current state of the downstream pilot will be shown in the drop down box. Changes must be saved. Note: The Downstream Pilot interface will be disabled if the Downstream Pilot jumper (JU3) is not in the Auto position. The downstream pilot state will be maintained through a DRX power cycle MultiCOM Compatibility MultiCOM amplifier diagnostic data can be retrieved and displayed using the Smart Com 150 DRX. The serial cable provided must be connected between the DRX's RS232 Input connector (P6) and the MultiCOM diagnostic receiver's DB9 connector. Proper polarity must be observed when connecting to the DRX. Note: MultiCOM amplifiers must be added to the web interface before amplifier data will be displayed (See Configuring Amplifiers) DRX Network Reset This feature allows the user to restore the default DRX network settings using the IP Default jumper. 1. Remove the top cover of the Head End enclosure. 2. Locate the IP Default jumper (JU1) on the DRX. C:\Workspace\...\help\help_en.xml page 5 of 56

6 3. Ensure the jumper is in place over both pins and cycle power to the DRX. This will reset the DRX to the following default values. IP Address: Netmask: Gateway: Remove the jumper from both JU1 pins. Warning Unless the jumper is removed from JU1, network settings will be reset each time power to the diagnostic receiver is cycled. 1.2 Server Diagnostics Web Server, a DHCP server (5 client license) and TFTP server. The DHCP/TFTP servers are intended to support Smart Com Ethernet installations. The server has two network interfaces, one of which is preconfigured to communicate directly with the RNG-DRX diagnostic receiver through cross-over cable. The other network interface is used to connect the server to the Server Installation for more information Server Specifications Server Specifications Form Factor Height Width 1U Rack 1.68" [4.27 cm] 17.60" [44.70 cm] C:\Workspace\...\help\help_en.xml page 6 of 56

7 Depth Weight 21.50" [54.61 cm] ~26.0 lbs [11.79 kg] Operating Temperature 10 to 35 degrees C [50 to 95 degrees F] Input Voltage VAC, 50/60 Hz Shelf Specifications Shelf Specifications Rack/Cabinet Size Form Factor Material Mounting Hardware Standard 19" EIA 4-post rack or cabinet 1U Rack 14 AWG Steel and mounting screws Dimensions (D x W x H) (20.25 to 33.25") x 19" x 1.25" [(51.4 to 84.5 cm) x 48.3 cm x 3.2 cm] Shelf Load Rating 150 lbs [68.0 kg] 2 DRX Installation 2.1 DRX Mounting and Power 1. If you have been supplied with a DRX in its own enclosure, mount the enclosure in the base station cabinet and skip to Step Otherwise, remove the cover of the head end enclosure. 3. Remove the nuts and washers from the bulkhead BNC connectors. Place the DRX in the enclosure as shown. Replace BNC fasteners. 4. Connect the power leads marked +12 Vdc (red) and GND (black) to the Base Stations 12 Vdc terminal block or power supply. 5. Connect a coaxial cable (1 m/3.3 ft, 50 ohm, BNC-BNC) between the DRX "Rx" connector (P3) and C:\Workspace\...\help\help_en.xml page 7 of 56

8 receive port 16 of the RNG-RF Connect a coaxial cable (1 m/3.3 ft, 50 ohm, BNC-BNC) between the DRX "Tx" connector (P2) and transmit port 16 of the RNG-RF16. Please note that some units may be fitted with an external Low Pass filter. This filter must remain in place for proper operation. 7. If MultiCOM diagnostics are required, connect the serial cable provided between the MultiCOM receiver and the RS232 Input connector (P6) on the DRX. Observe connector polarity. 2.2 Downstream Pilot Tuning Once the DRX has been installed and connected to the Smart Com 150/150IS system, the downstream pilot level must be calibrated. 1. Ensure power is applied to the DRX. Move the Downstream Pilot jumper, JU3, (see Hardware Overview) to the ON position. 2. Put the Head End (HE) amplifier in Manual Mode (JU30, amp) and apply 4 db of attenuation using the manual attenuation switch (IC14, amp). 3. Increase the downstream pilot output level using R48 (R29 on Rev C DRX boards) until the OK Led (D8) on the HE amplifier is lit. The DRX pilot has a maximum output level of +14 dbm. 4. Return the HE amplifier to Automatic mode (JU30, amp). 5. The downstream pilot can now be used in either local or remote mode. See Downstream Pilot for more information. 2.3 DRX Configuration The DRX is shipped from Varis with the following default settings: IP Address: Netmask: Gateway: Server IP: DRX Configuration with Varis Server Servers shipped with each Smart Com 150 head end have two Ethernet ports which are labelled DRX and LAN. One connects directly to the DRX and the other to the mine's LAN. If you are using the server provided and configured by Varis the DRX will require no configuration. Simply connect the DRX to the server Ethernet port labelled DRX using a crossover cable. The settings for the LAN port will still have to be changed to match those of the mine's LAN. See Server Configuration DRX Configuration Using Customer Provided Server If you are using a server other than the one provided by Varis, it's likely that you will have to configure the DRX settings. Initially you will have to change the settings locally. Once initial communication has been established between the RD software and DRX, the network settings can be changed remotely Changing DRX Network/Server Settings Locally If the diagnostic receiver is not on the same network as the web server, you will have to connect through cross-over cable. 1. If the current IP address of the DRX is known, skip to Step 2. Otherwise the DRX's IP address must be C:\Workspace\...\help\help_en.xml page 8 of 56

9 reset to it's default value ( ). See DRX Network Reset. 2. Connect a cross-over cable between a PC and the RJ-45 connector on the DRX. 3. Access Network Connections administration from the PC's Control Panel. 4. Double-click on Local Area Connection to access the following dialog box. 5. Click on the Properties button. The following screen should be displayed. C:\Workspace\...\help\help_en.xml page 9 of 56

10 6. Select Internet Protocol (TCP/IP) from the list box and click the Properties button. 7. Assign the PC an IP address, Netmask and Gateway IP that correspond to the network for the which the DRX is currently configured. The values shown correspond to the default network settings of the diagnostic receiver (IP Address = , Netmask = , Gateway = ). Please note that the PC's IP address cannot be the same as the DRX's IP address. 8. Once the network settings have been modified, you can verify the PC's current IP address. Open a command prompt (or click Start -> Run and type cmd). 9. At the prompt type ipconfig to view the PC's current network settings. C:\Workspace\...\help\help_en.xml page 10 of 56

11 10. The DRX WebServer IP must be configured to match the IP address of the PC on which the web server software is running. The configuration interface can be accessed at (substitute the DRX IP address if different than shown). Configure the web server IP address and submit changes. The Port Number shown below is the port on the server PC used to receive data from the DRX unit and should be left to the default value of Next, access the DRX's network configuration page by typing (substitute the DRX's IP address if different than shown). Enter the new IP address, Gateway and Netmask that correspond to the mine's network. Submit changes. C:\Workspace\...\help\help_en.xml page 11 of 56

12 12. Reconnect the DRX to the mine's network using a straight-through network cable. The web server will automatically update it's DRX settings when the DRX first calls in to the server. Verify that the DRX is communicating with the web server by checking the DRX Status (top left of main page on web server). A check mark will be shown if the DRX and web server are configured properly Changing DRX Network/ Server Settings Remotely 1. If the DRX and webserver are communicating successfully (DRX status ), you can connect to the DRX web interface by clicking on the DRX link from the RD webserver's Administration menu. This will open the DRX's main web interface in a separate window. 2. Click on Network Settings to access the DRX's network configuration page. Enter the new IP address, Gateway and Netmask that correspond to the mine's network. Submit changes. 3. Go back to the DRX's main web interface and click on Web Server Settings. Configure the web server IP address and submit changes. The Port Number is the port on the server PC used to receive data from the DRX unit and should be left to the default value of 4322 C:\Workspace\...\help\help_en.xml page 12 of 56

13 3 Server Installation 3.1 Server Mounting and Power adjustable rack shelf provided. The rack shelf will adjust to cabinet depths of to 33.25" (51.4 to 84.5 cm). 1. Adjust shelf to proper depth and install in cabinet using the 4 mounting screws provided. 2. Place server computer on shelf and secure to rack by tightening the front mounted screws on the server. 3. Server Configuration), connect the server to the 4. Connect the DRX to Network Adapter 2 (labeled DRX) on the server using a cross-over cable. The server and DRX are pre-configured to communicate on this network interface. 5. Attach power cord to server and turn on. 3.2 Server Configuration The server is not supplied with a monitor, keyboard or mouse. For initial setup, you must either attach these peripherals or use Remote Desktop to remotely configure the server. Connecting Through Remote Desktop: 1. Connect to Network Adaptor 1 on the server using a cross-over cable. 2. Change your IP settings to be on the same subnet as the server. The default IP settings of the server are as follows: IP Address: Subnet: Gateway: Configure Server IP Settings: 1. Login to server. Username: Administrator Password: Varis From the Start menu, click Run to open the Run command box. Type ncpa.cpl into the textbox and click OK. This should open the Network Connections page 3. Right-click on Network Connection 1 and select Properties. 4. In the Connection Properties window, double-click on Internet Protocol Version 4(TCP/IPv4) to open its IP properties page. 5. OK to save and then Click OK again to exit the Connection Properties window and apply the changes 6. Chapter 4: Smart Com 450/450IS Hardware 1 Overview C:\Workspace\...\help\help_en.xml page 13 of 56

14 Remote diagnostics are built in to every Smart Com 450/450IS line amplifier and head end. These components require no special configuration to provide Remote Diagnostic data to the mine's network via the head end server. 2 Installation Smart Com 450/450IS hardware requires no configuration upon installation to provide Remote Diagnostics. The only action required to receive RD data from an amplifier is to add the amplifier ID to the RD web interface and to connect the hardware required for remote diagnostics (Server, Head end, Line amplifier) as shown below. 2.1 Connecting the Head End 1. The server must be installed in the base station cabinet. See Server Installation for more information. 2. Install head end in base station cabinet. 3. Connect the Head End and server using the serial cross-over cable provided. 4. Connect the Head End to the LF network through Branches 1 to 4. See Smart Com 450/450IS manual for more information. C:\Workspace\...\help\help_en.xml page 14 of 56

15 Chapter 5: Running the RD Web Server By default, the RD Web Server is installed as a Windows service. As such, the RD software will automatically start when Windows is started. Controlling the RD Service Manually: 1. To stop and start the service manually, click Start -> All Programs -> Smart Com Remote Diagnostics -> Configure web server. This will open the Varis Web Server Properties panel, shown below: 2. Under Startup type, you can set the web server to start automatically when Windows starts (default). Or you can set it to start manually, using the control buttons. The control buttons at the bottom of the page allow you to Start, Stop, Pause and Restart the web server. Accessing the RD webpage: To verify that the web server is running properly, type in the IP address of the computer on which the RD web server is installed (i.e., Note: The Internet Protocol defines the special network address, , as a local loop back address. Hosts use local loop back addresses to send messages to themselves. This will only point to the RD web server when working from the computer on which the RD web server is installed. To access the Remote Diagnostic web page from a different computer, you must substitute the local loop back address ( ) with the IP address of the machine running the RD Web Server. You should be redirected to the login page as shown below (See User Access). C:\Workspace\...\help\help_en.xml page 15 of 56

16 Chapter 6: Getting Started 1 User Access There are two user types defined in the system: Administrator and Viewer. Administrators can change settings that are not available to Viewers. Only administrators have access to the following features. Adding/Editing/Deleting/Unassigning amplifiers Configuring Network and Mail settings Downstream Pilot control Changing user passwords Database backup/restore Configuring alarm thresholds, deleting alarms. The user name for Administrators is admin and the default password is admin. The user name for Viewers is viewer and the default password is viewer. Note: It is highly recommended that you log in as an Administrator and change the passwords from their default value. 1.1 Changing Passwords 1. Connect to the web server by typing the IP address of the device on which the web server is running (i.e., 2. To change passwords login as an Administrator (user name = admin, default password = admin). C:\Workspace\...\help\help_en.xml page 16 of 56

17 3. Click on the Admin link in the upper right-hand corner of the main page. This will take you to the system Administration page. 4. Next, click on the Users link on the administration menu. You should see the following screen. 5. In order to change the Administration password, click on the Change password link next to admin. Enter the new password on the form provided and click Save. Repeat the same procedure for the Viewer account. 2 DRX Network Settings Before the system will function properly, you must configure the network settings of the DRX (See DRX Configuration). Communication status between the DRX and web server is shown at the top left-hand corner of the server's web interface (DRX status ). Clicking on the DRX status icon will open the status box, which indicates how long it has been since the last successful communication. If the DRX has not communicated in over 1 minute, the status will show a warning icon (DRX Status ). This indicates that the DRX has not been configured correctly or that there may be a firewall blocking communication. See Frequently Asked Questions for more information. If the DRX is communicating successfully (DRX status ), and you would like to make changes to the settings on the DRX, you can connect to the DRX web interface by clicking on the DRX link in the Administration menu. This will open the DRX web interface in a separate window. See DRX Configuration for more information about the various settings. 3 Mail Settings The RD Web Server can be configured to output notification of alarm conditions. C:\Workspace\...\help\help_en.xml page 17 of 56

18 1. Connect to the web server by typing the IP address of the device on which the web server is running (i.e., 2. Login to the RD interface as an Administrator (See User Access). 3. Open the Administration interface by clicking on the Admin link on the upper right-hand corner of the page. Next, click on Mail Settings from the administration menu. Each of the fields are described below: Mail Server: The name of your SMTP mail server. Port: The SMTP port used by the mail server. Username: The SMTP server account user name. Password: The SMTP server account password. From Address: The address from which the will be sent. This address will appear in the From field of the that is sent. Any address can be specified as long as it is in proper format (i.e., Recipients: The addresses where should be sent. Multiple addresses must be separated by a single comma (i.e., joe@somewhere.com,sally@somewhere.com). 4. When you have finished editing the fields, click the Save button to activate the new settings. The mail C:\Workspace\...\help\help_en.xml page 18 of 56

19 settings can be verified by selecting the Test button. This will send an to each of the recipients specified. 4 Viewing Amplifier and Ethernet Data Version (and later) is able to provide Remote Diagnostic data for both Varis's Smart Com 150/150IS and Smart Com 450/450IS systems. There are two ways of selecting which interface is available and shown on the main page. 1. During installation you will be asked whether you want the software to show the interface for the Smart Com 150 system, Smart Com 450 system or for both. If you select only one system or the other, only information for that system will be available from the main interface. If you selected both systems during installation, data for both systems will be available from the main interface. You will be able to switch between the RD data for both systems via the link shown on the top of the screen. 2. Another way of changing which systems are available from the main interface is through the administration interface. Clicking on the Admin link at the top right hand corner of the page will bring you to the Administration menu. From here, click on the System tab to see the following screen. C:\Workspace\...\help\help_en.xml page 19 of 56

20 From this tab you can select which system type(s) you want available from the main interface. If you only select 150 or 450 then only one system is available from the main interface. If you select 150,450 then both are available and you can toggle between them using the link at the top of the page. 4.1 Viewing Smart Com 150/150IS RD Data To view Smart Com 150/150IS amplifier, MultiCOM amplifier or Smart Com Ethernet data, point your browser to the main page ( Ensure that the Smart Com 150 system is displayed. Initially, each branch will be empty and you will not see any amplifiers or Ethernet devices. C:\Workspace\...\help\help_en.xml page 20 of 56

21 If the DRX is configured properly, Varis amplifiers will be automatically added to the UNASSIGNED AMPLIFIERS section when they call in. MultiCOM amplifiers must be added before MultiCOM diagnostic data will be displayed. Head end amplifiers with the latest firmware will be automatically added to the Head End branch. The following screen shot is of a fully configured system with multiple amplifiers. C:\Workspace\...\help\help_en.xml page 21 of 56

22 Clicking on the branch name will toggle the displayed state of the items within a branch. Note: Varis amplifiers are indicated by a icon while MultiCOM amplifiers are indicated by a icon. The icon is used to indicate a CMTS and the icon is used to indicate cable modems. 4.2 Viewing Smart Com 450/450IS RD Data To view Smart Com 450/450IS amplifier or Smart Com Ethernet data, point your browser to the main page ( Ensure that the Smart Com 450 system is selected from the link at the top of the main interface. C:\Workspace\...\help\help_en.xml page 22 of 56

23 Initially, each branch will be empty and you will not see any amplifiers or Ethernet devices. In order to view Smart Com 450/450IS amplifier data, the amplifier ID must be added to the main interface (See Adding Amplifiers). Once the amplifier ID has been added, the RD software will poll the amplifier at an interval related to the size of the system (i.e., If the system has fewer amplifiers, then each amplifier will be polled more often). Note: Varis amplifiers are indicated by a icon. The icon is used to indicate a CMTS and the icon is used for cable modems. 4.3 Viewing Smart Com Ethernet RD Data Ethernet devices will not show up until a CMTS is defined (see Configuring Ethernet Devices). Once a CMTS has been added to the system, the web interface will automatically show all connected cable modems. Note: The icon is used to indicate a CMTS and the icon is used for cable modems. 4.4 Enabling/Disabling Auto-Refresh By default, the main amplifier list page is designed to automatically refresh every 45 seconds. This feature can be controlled by clicking on the On or Off link found at the top right of the web interface's main page. C:\Workspace\...\help\help_en.xml page 23 of 56

24 4.5 Manually Refreshing an Amplifier Clicking on an amplifier number from the main page will open the Amplifier Options dialog shown below. Clicking on the Refresh Data link will force the system to poll the selected amplifier for new diagnostics data. 4.6 Amplifier History Clicking on an amplifier number from the main page will open the Amplifier Options dialog shown below. Selecting the View history link will open the Amplifier History page for the selected amplifier. This screen is shown below. C:\Workspace\...\help\help_en.xml page 24 of 56

25 This screen shows a graphical display of amplifier data over time. Using the check boxes along the top, you can control which values are displayed on the graph (RF Downstream power, Attenuation, and Voltage). You can also set the time period for which the data is retrieved by adjusting the Start Time and Resolution. Start Time can be changed using the calendar component shown below. This component allows you to select both the date and time. The Resolution is adjusted using the drop down box shown below. C:\Workspace\...\help\help_en.xml page 25 of 56

26 The resolution sets the interval for data retrieval. There are 5 options: 10 minutes, 1 hour, 4 hours, 10 hours, and 24 hours. If you set the resolution too fine, you may get too much data to be displayed on the graph. If this happens, you must reduce the resolution until the data fits. Clicking the Live check box will provide a live view, retrieving the current amplifier data. The start time will be automatically offset based on the current resolution setting such that Start Time + Resolution = Current Time. This screen will automatically update every 10 seconds. You can also use the navigation arrows, shown below, to move the time range forward or backward by predefined amounts (10 minutes, 1 hour, 24 hours). The current time range is shown to the right of these arrows. 4.7 Ethernet Device History Clicking on the CMTS or one of the cable modems in the Ethernet branch will display a detailed information box for the selected device, as shown below: To view device history data, click the View History link at the bottom of the information box ( icon). You should C:\Workspace\...\help\help_en.xml page 26 of 56

27 see a screen similar to the one shown below: This screen shows a graphical display of cable modem diagnostic data over time. Using the check boxes along the top, you can control which fields are displayed on the graph (Downstream Power, Upstream Power, and Signal-to-Noise). You can also control the time period for which the data is retrieved by setting the Start Time and the Resolution. The Start Time can be changed using the calendar component shown below. This component allows you to select both the date and time. The Resolution is adjusted using the drop down box shown below. C:\Workspace\...\help\help_en.xml page 27 of 56

28 The resolution sets the interval for data retrieval. If you set the resolution too fine, you may get too much data to be displayed on the graph. If this happens, you must reduce the resolution until the data fits. Clicking the Live check box will provide a live view of the current Ethernet device data. The start time will be automatically offset based on the current resolution setting such that Start Time + Resolution = Current Time. This screen will automatically update every 10 seconds. You can also use the navigation arrows shown below to move the time range forward or backward by predefined amounts (10 minutes, 1 hour, 24 hours). The current time range is shown to the right of the arrows. 5 Configuring Amplifiers Varis' Remote Diagnostics allows you to order amplifiers such that it reflects the actual system layout. Each of the four branches on the main interface can contain a tree of amplifiers with subbranches (See Layout Example). Note: When a Varis amplifier initially reports in to the diagnostic receiver, it will be displayed under "Unassigned Amplifiers" until otherwise configured. MultiCOM amplifiers do not automatically add themselves to the unassigned amplifiers branch. Instead, MultiCOM amplifiers must be added before amplifier data will be displayed on the interface. Head end amplifiers with the latest firmware will be automatically added to the Head End branch. 5.1 Adding Amplifiers 1. To add an amplifier to the system, click on the Add Amp link next to the branch you would like to add the amplifier to. You should see a screen similar to the one below: C:\Workspace\...\help\help_en.xml page 28 of 56

29 The New Amplifier form has the following fields: Amplifier ID - The unique ID number of the amplifier you are adding to the system. The Amplifier ID must be in the form of 255.nnn.xxx for Varis Smart Com 150 amplifiers, 254.nnn.xxx for Varis Smart Com 150IS amplifiers, 100.nnn.xxx for Varis Smart Com 450 amplifiers, and 1.nnn.xxx or 5.nnn.xxx for MultiCOM amplifiers. Each number "nnn" must be in the range of 0 to 255 and each number "xxx" must be in the range of 1 to 255. Location - A general description of the amplifier's location. The Location field is optional but it is recommended that you enter a meaningful description of the amplifier's physical location. For example, "2300L Refuge Station". Branch - The branch you are adding the amplifier to. Insert - Where to insert the amplifier relative to another amplifier (defined by the "Amp" field). Can be one of "before", "after", or "as branch under". The Insert and Amp fields are used together to determine where the amplifier is to be placed in the tree. For example, "Insert before Amp " would insert the new amplifier before amplifier in the tree. To simulate a splitter between amplifiers, you would select "Insert as branch under Amp " (See Layout Example). Amp - The related amplifier. 2. Click the Save button to commit the changes. The main page should now contain your newly added amplifier. Note: You can also add amplifiers by clicking on one of the buttons next to the amplifiers. This will automatically setup the new amplifier form to insert after the amplifier you clicked the button for. For example, clicking next to amplifier will automatically preselect the Insert and Amp fields on the new amplifier form to read "Insert after Amp This makes it quicker and easier to add amplifiers one after another. C:\Workspace\...\help\help_en.xml page 29 of 56

30 5.2 Editing Amplifiers To edit an amplifier, click the corresponding edit button (same row as amp) to open the edit amplifier form. The edit screen allows you to change the amplifier ID, location descriptor and placement of the amplifier. Select the icon to change the amplifier ID to a new ID or the ID of any amplifier in the Unassigned Amplifiers branch. The amplifier being replaced will be moved to the Unassigned Amplifiers branch. 5.3 Deleting Amplifiers In order to delete an amplifier, click on the delete button next to it. You will be asked to confirm removal of the amplifier. Click OK to delete the amplifier and return to the main page. Note: An amplifier with subbranches must have an amplifier above it (in the listing) before it can be deleted. Otherwise, each subbranch amplifier must be first deleted. If amplifier were deleted from the listing shown below, amplifier would replace it's position in the tree structure. C:\Workspace\...\help\help_en.xml page 30 of 56

31 You can also delete all the amplifiers in the system by clicking the Admin link in the upper right-hand corner of the page and then clicking on the Amplifiers link. This will open the Amplifiers administration page, shown below. C:\Workspace\...\help\help_en.xml page 31 of 56

32 Click on the Delete all amplifiers link to permanently delete all amplifiers. Warning: this cannot be undone! 5.4 Defining the Head End Amplifier (Smart Com 150/150IS Only) Newer versions of the amplifier firmware allow the RD web server to differentiate between line and head end amplifiers. Based on the amplifier type, the RD web server will either automatically populate the Head End branch or add the new amplifier to the Unassigned Amplifiers branch. If the Head End amplifier is added to the Unassigned Amplifiers branch (older firmware), it must be configured according to the following procedure. 1. Connect to the web server by typing the IP address of the device on which the web server is running (i.e., 2. Login to the RD interface as an Administrator (See User Access). 3. Click on the Edit button under the HEAD END section and you should see a screen similar to the following. C:\Workspace\...\help\help_en.xml page 32 of 56

33 4. From the Change to drop down menu, select the amplifier you would like to set as the Head End. If there are no amplifiers in the system yet, see the Adding Amplifiers section. You may also enter the location of the Head End in the Location field. 5. Click the Save button to commit the changes. 5.5 Ordering Branches Amplifiers may be branched from a single amplifier to represent splitters in your system. These branches can be reordered by selecting the icon next to the parent amplifier. This is shown below next to amplifier C:\Workspace\...\help\help_en.xml page 33 of 56

34 A screen similar to the one below should be displayed. C:\Workspace\...\help\help_en.xml page 34 of 56

35 Move the branches into proper order and save changes. 5.6 Layout Example The following procedure describes how to add amplifiers to the main interface such that they represent the following layout. Amplifier is the head-end amp and only two of four possible branches are shown. 1. Login to the RD interface as an Administrator (See User Access). 2. Click on the Add Amp link from the Unassigned Amplifiers title bar. Type in the head end amplifier ID and save the changes. Amplifier will now be listed under Unassigned Amplifiers. 3. Next, click on the Edit button under the HEAD END section. Select amplifier from the Change to drop down box. Give the amplifier a location descriptor. Please note that the head end amplifier may be automatically added with newer versions of the amplifier firmware (See Defining the Head End Amplifier for more information). 4. Add amplifier to Branch 1 by clicking the Add Amp link from the Branch 1 title bar. 5. Add amplifier by clicking on the Add Amp icon next to amplifier Add amplifier to Branch 2 by clicking the Add Amp link from the Branch 2 title bar. C:\Workspace\...\help\help_en.xml page 35 of 56

36 7. Add amplifier by clicking on the Add Amp icon next to amplifier Add amplifier as a branch under by clicking on the Add Amp icon Select As Branch Under from the Insert drop down box. Save changes. next to amplifier The amplifier listing shown below reflects the actual amplifier layout. 5.7 Unassigning Amplifiers Removing a single amplifier from a branch and placing it in the Unassigned Amplifiers branch can be accomplished by clicking the edit icon ( ) next to the amplifier you would like to remove. This will open the Edit Amplifier box as shown below: C:\Workspace\...\help\help_en.xml page 36 of 56

37 Next, select Unassigned Amplifiers for the Branch and click Save. It is also possible to unassign all amplifiers in a branch, or even all amplifiers in the system all at once. To do this, click on the Admin link in the upper right-hand corner of the page and then click on the Amplifiers link. This will open the Amplifiers administration page, shown below. C:\Workspace\...\help\help_en.xml page 37 of 56

38 Next, click the Unassign all amplifiers link to unassign all amplifiers in the system. Or, choose a branch (1-4) from the drop down menu. 5.8 Adjusting Atttenuation Settings (Smart Com 450/450IS Only) To adjust the CMTS attenuation settings for an amplifier, click on an amplifier number from the main page. This will open the Amplifier Options dialog shown below. Click on the Adjust attenuation settings link to display the Attenuation Settings dialog shown below. C:\Workspace\...\help\help_en.xml page 38 of 56

39 The dialog displays the current Upstream and Downstream CMTS attenuation settings along with corresponding recommended values for each. The recommended value is calculated from the voice channel attenuation. Clicking on the help button displays a table showing the complete list of recommended values. To change the attenuation settings, edit the value in the corresponding text box and click the Save button. 6 Configuring Ethernet Devices Varis' Remote Diagnostics allows you to view CMTS and cable modem diagnostic data on systems equipped with these devices. Before you can receive Ethernet diagnostic information, you must first add the CMTS to the RD webserver. Once the CMTS is added, all of it's attached cable modems will show up automatically. 6.1 Adding a CMTS 1. To add the CMTS to the system, click on the Add CMTS link next to the Ethernet branch. You should see a screen similar to the one below: C:\Workspace\...\help\help_en.xml page 39 of 56

40 The New CMTS form has the following fields: IP Address - The IP address of the CMTS you are adding to the system. Location - A general description of the CMTS location. The Location field is optional but it is recommended that you enter a meaningful description of the CMTS's physical location. For example, "Base Station". 2. Click the Save button to commit the changes. The main page should now contain your newly added CMTS. 6.2 Editing Ethernet Devices To edit the CMTS click the corresponding edit button and location descriptor of the CMTS.. The edit CMTS form allows you to change the IP address To edit a cable modem click the corresponding edit button. The edit cable modem form allows you to change C:\Workspace\...\help\help_en.xml page 40 of 56

41 the location descriptor of the cable modem only. 6.3 Deleting Ethernet Devices In order to delete an Ethernet device, click on the delete button next to it. Note: If you delete the CMTS, you will also delete all of its attached cable modems. You will need to re-add a CMTS in order to get Ethernet diagnostics information (See Adding a CMTS). If you delete a cable modem, and it is still physically connected to the system, it will reappear after a couple of minutes. Chapter 7: Understanding Smart Com 150/150IS Amplifier Data The amplifier ID, location, RF downstream signal strength, RF upstream signal strength, attenuator setting, mode, voltage, and time since last report are displayed for each amplifier. Following is a description of these data reports. Amplifier Number: This is a unique 24 bit identifier which has been programmed into each amplifier (i.e., Varis, MultiCOM). The Amplifier ID must be a valid ID number in the form of 255.nnn.nnn for Smart Com 150 amplifiers, 254.nnn.nnn for Smart Com 150IS amplifiers and 1.nnn.nnn or 5.nnn.nnn for MultiCOM amplifiers. Varis amplifiers are indicated by a icon while MultiCOM amplifiers are indicated by a icon. Location: Down indicates signal presence and strength. In a properly functioning Varis system, RF Down can vary from -16 dbm (no signal present) to +6 dbm (signal present) for line amplifiers in a non-piloted system. The output signal strength during signal transmission can vary between +2 and +6 dbm (Varis line amplifier). Please note that Varis head end amplifiers have an output signal strength 5 dbm higher than line amplifiers. This information is available for both Varis and MultiCOM amplifiers. Up: This value shows the RF upstream signal strength (dbm). This information is available for MultiCOM amplifiers only ("--" is displayed for Varis amplifiers). Atten: This value is shown for Varis amplifiers only ("--" is displayed for MultiCOM amplifiers). This shows the Automatic mode, the attenuation applied by the CPU is displayed. While the amplifier is in manual mode, the Atten field shows the position of the manual attenuation switch (IC14) located on the amplifier board. An attenuation value of 0 db indicates that the amplifiers gain is at 100%. Alternately, an attenuation of 15 db indicates that maximum attenuation is being applied by the amplifier. Note: An attenuation of 5 db or more indicates that this amplifier has enough gain that it could possibly be moved further out along the Smart Com system. Contact a Varis technician for more information. Varis Modes: This data field indicates whether the amplifier is running in Automatic or Manual mode. The amplifiers mode setting is determined by the position of the mode jumper (JU30) on the front of the amplifier board. controlled by the position of the attenuation switch (IC14). C:\Workspace\...\help\help_en.xml page 41 of 56

42 MultiCOM Modes: MultiCOM amplifiers may display several modes depending on the position of the Mode jumper/switch and the Return pilot generation feature. Valid modes and their jumper/switch position are shown in the following table. MultiCOM Modes Mode IN IP BN Description Position 1 - This amplifier detects a Return pilot and has disabled its pilot generation feature (See Note 3). Position 1 - The amplifier does not detect a Return pilot and has generated its own pilot (See Note 4). Position 7 - This amplifier is in "Branch Mode" and is operating at maximum gain. Ensure 350 meter spacing is strictly adhered to. (See Note 1) RP Position 8 - This amplifier's Return pilot ( MHz) has been enabled (See Note 2). NJ No jumper is installed. Immediate repair is required. **All other modes are factory settings and should not be used. Notes: 1. For any branch with less than 5 amplifiers, select jumper position 7. This will cause the amplifier to run at full gain and may increase the overall Return noise floor, but is preferable to having another pilot for the branch. This will reduce Return pilot noise in a MultiCOM system. 2. Enable the MHz pilot tone for any amplifier at the end of a long branch (more than 6 amplifiers). 3. Always select jumper position 1 if the amplifier does not meet the criteria outlined in Notes 1 and Any MultiCOM amplifier in "IP" mode indicates that there is a cabling or pilot fault. Immediate repair is required. Voltage: This value indicates the DC Line voltage detected at the amplifier. Report: The number of minutes that have elapsed since the amplifier last reported to the DRX. A maximum of 24 hours will be displayed. Chapter 8: Understanding Smart Com 450/450IS Amplifier Data The amplifier ID, location, RF downstream signal strength, RF upstream RSSI, attenuator settings, mode, voltage, and time since last report are displayed for each amplifier. Following is a description of these data reports. Amplifier Number: This is a unique 24 bit identifier which has been programmed into each amplifier (i.e., ). The Amplifier ID must be a valid ID number in the form of 100.nnn.xxx. Each number "nnn" must be in the range of 0 to 255 and each number "xxx" must be in the range of 1 to 255. Location: Down indicates signal presence and strength. The target RF Downstream power level for Smart Com 450/450IS amplifiers is -5 dbm. RSSI: This value shows the RF upstream signal strength (dbm) as measured at the head end input. Upstream C:\Workspace\...\help\help_en.xml page 42 of 56

43 signals leave each amplifier at -20 dbm and should reach the head end between -30 dbm and -42 dbm. Atten amplifier is in Automatic mode, the attenuation applied by the CPU is displayed. While the amplifier is in manual mode, the Atten field shows the position of the manual attenuation switch (SW1) located on the amplifier board. Clicking on the attenuation value will bring up a screen that shows the attenuation setting for each bandpass: Voice Downstream, Voice Upstream, CMTS Downstream and CMTS Upstream. Mode: This data field indicates whether the amplifier is running in Automatic or Manual mode. The amplifiers mode setting is determined by the position of the mode jumper (JU16) on the front of the amplifier board. While the switch (SW1). Voltage: This value indicates the DC Line voltage detected at the amplifier. Report: The number of minutes that have elapsed since the amplifier last reported. A maximum of 24 hours will be displayed. Chapter 9: Understanding Ethernet Data 1 CMTS Data Downstream power, and time since last report are displayed for the CMTS on the main page. Detailed CMTS info can be viewed by clicking on the CMTS IP in the device list. C:\Workspace\...\help\help_en.xml page 43 of 56

44 Following is a description of these data reports. Model: Model name of the CMTS. For example, "C3" refers to the Arris Cadant C3 CMTS. MAC: The MAC (Media Access Control) address of the CMTS. A MAC is a hardware address that uniquely identifies each node of a network. Up Time: The amount of time since the CMTS was last reinitialized. Down Channel Power: The downstream channel's transmit power-level from the CMTS. Frequency: The downstream channel's center frequency. Width: The bandwidth of the downstream channel. Modulation: The modulation type associated with the downstream channel (QAM 64 or QAM 256). Up Channel Frequency: The center frequency of the upstream channel. Width: The bandwidth of the upstream channel (3.2 MHz or 6.4 MHz). 2 Cable Modem Data Downstream power, upstream power, receive signal-to-noise ratio, lost syncs and time since last report are displayed for each cable modem on the main page. Detailed cable modem info can be viewed by clicking on the cable modem in the device list. This will bring up the cable modem Info box as shown below: C:\Workspace\...\help\help_en.xml page 44 of 56

45 Following is a description of these data reports. Model: Model name of the cable modem. For example, "CM550A" refers to the Arris Touchstone CM550A cable modem. MAC: The MAC (Media Access Control) address of the cable modem. A MAC is a hardware address that uniquely identifies each node of a network. Up Time: The amount of time since the cable modem was last reinitialized. Packet Stats Undamaged: Number of data packets that arrived undamaged. Corrected: Number of packets that arrived damaged, but could be corrected. Uncorrectable: Number of packets that arrived so damaged that they were discarded. Error Rate: The packet error rate (uncorrectable / total packets). Down Channel Power: The downstream power level detected at the cable modem. Frequency: The downstream channel's center frequency. Width: The bandwidth of the downstream channel. Modulation: The modulation type associated with the downstream channel. Should be either QAM 64 or QAM 256. Up Channel Power: The power level of the upstream channel (transmitted from the cable modem). Frequency: The center frequency of the upstream channel. Width: The bandwidth of the upstream channel. C:\Workspace\...\help\help_en.xml page 45 of 56

46 Chapter 10: Alarms The web interface will show voltage and RF alarms/warnings for amplifiers as well as various alarms/warnings for Ethernet devices. These are shown by highlighting the device ID in red (alarm) or orange (warning) and includes a brief description in the Alarm listing. The value with an alarm/warning condition is also highlighted in red/orange. notification of alarms can be configured (See Mail Settings) Viewing All Alarms A complete alarm list can be seen by clicking on the Show All link above the message listing. Deleting All Alarms To delete all stored alarms, click on the on Show All link above the alarm listing on the main page. Next, select the Clear All link from the Alarm listing title bar. It is recommended that alarms which no longer exist in the system be deleted from the alarm listing. This will ensure that notification is generated each time a new alarm condition occurs. Deleting Individual Alarms To delete an individual alarm, click on the Show All link above the alarm listing on the main page. Next, click on the delete icon associated with the alarm you want to delete. 1 Defining Alarm Thresholds The RD web server allows for complete control over setting alarm thresholds for Smart Com 150/150IS, Smart Com 450/450IS and MultiCOM amplifiers. The following procedure outlines alarm/warning threshold selection. 1. Connect to the web server by typing the IP address of the device on which the web server is running (i.e., 2. Login to the RD interface as an Administrator (See User Access). 3. Open the Administration interface by clicking on the Admin link on the upper right-hand corner of the page. Next, click on Alarms from the administration menu. C:\Workspace\...\help\help_en.xml page 46 of 56

47 4. Enter the desired Low and High alarm/warning threshold values and save the changes. Click on the help icon to view typical settings for a field. 5. To reset a particular set of fields back to their defaults, click the Reset button next to the row of fields. To reset ALL of the alarm thresholds, click the Reset All button and save changes. Note: Cable modem alarm thresholds are not configurable through this interface. 2 Default Thresholds Although the alarm thresholds can all be customized, the default settings should work for most installations. For reference, the default thresholds are listed below. After making any changes, you can easily revert back to the default settings by using the Reset buttons. 2.1 Smart Com 150 Amplifiers Voltage: Low Alarm: 8.0 VDC High Alarm: 37.0 VDC C:\Workspace\...\help\help_en.xml page 47 of 56

48 RF Downstream: Low Alarm: -4 dbm (1 dbm for head end amplifiers) Low Warning: 0 dbm (5 dbm for head end amplifiers) High Warning: 6 dbm (11 dbm for head end amplifiers) High Alarm: 7 dbm (12 dbm for head end amplifiers) 2.2 Smart Com 150IS Amplifiers Voltage: Low Alarm: 5.9 VDC Low Warning: 7.6 VDC High Warning: 12.1 VDC High Alarm: 12.3 VDC RF Downstream: Low Alarm: -4 dbm (1 dbm for head end amplifiers) Low Warning: 0 dbm (5 dbm for head end amplifiers) High Warning: 6 dbm (11 dbm for head end amplifiers) High Alarm: 7 dbm (12 dbm for head end amplifiers) 2.3 Smart Com 450 Amplifiers Voltage: Low Alarm: 6.0 VDC Low Warning: 7.0 VDC High Warning: 16.0 VDC High Alarm: 17.0 VDC RF Downstream: Low Alarm: -8 dbm Low Warning: -7 dbm High Warning: -3 dbm High Alarm: -2 dbm 2.4 Smart Com 450IS Amplifiers Voltage: Low Alarm: 6.0 VDC Low Warning: 7.0 VDC High Warning: 12.0 VDC High Alarm: 12 VDC RF Downstream: Low Alarm: -8 dbm Low Warning: -7 dbm High Warning: -3 dbm High Alarm: -2 dbm C:\Workspace\...\help\help_en.xml page 48 of 56

49 2.5 MultiCOM Amplifiers Voltage: Low Alarm: 7.5 VDC Low Warning: 8 VDC RF Downstream: Low Alarm: -4 dbm Low Warning: 0 dbm RF Upstream: Low Alarm: -10 dbm Low Warning: -6 dbm 2.6 Cable Modems Downstream Channel: Low Alarm: < 5 dbmv Low Warning: < 10 dbmv High Alarm: > 15 dbmv Upstream Channel: Low Alarm: < 10 dbmv Low Warning: < 15 dbmv High Warning: > 40 dbmv High Alarm: > 45 dbmv Signal to Noise Ratio: Low Alarm: < 29 Low Warning: < 35 Chapter 11: Database The Remote Diagnostics web server stores it's data in a Microsoft SQL Server 2005 Express Edition database. The Database administration screen allows you to backup the database, or restore the database from a previous backup. It also allows you to delete old data that may no longer be needed. It is highly recommended that you make occasional backups of your database file, especially after making structural changes to the amplifier layout. That way, if there is ever a problem, you can restore the database to a known working state without having to rebuild your amplifier layout manually. It is also recommended that you delete old data periodically. This will help conserve disk space and improve performance of the Remote Diagnostics system. To access the Database administration screen, you must first be logged in as an Administrator (See User Access). Next, open the Administration interface by clicking on the Admin link in the upper right-hand corner of the page. Then, click on the Database link from the administration menu and you should see a screen similar to the one shown below: C:\Workspace\...\help\help_en.xml page 49 of 56

50 1 Backing up the database To backup the database, click on the Backup database link as shown above. You will then be prompted to Open or Save the file, as shown below. Click Save and then choose a safe location to save the file. 2 Restoring the database To restore the database from a backup, perform the following steps: 1. Click the Browse... button next to Restore database. 2. From the Windows file chooser dialog that appears, find and select the backup file you would like to restore. 3. Click the Restore button. You will be asked to confirm that you want to overwrite your current database C:\Workspace\...\help\help_en.xml page 50 of 56

51 with the file you selected in the previous step. Click OK to proceed. Chapter 12: Searching for Amplifiers You can search for a particular amplifier by typing the amplifier's ID number into the Find Amplifier search box and pressing Enter. If the amplifier exists in the system it will be highlighted in the amplifier list as shown in the screen shot below: Chapter 13: Updating Amplifier Firmware Smart Com 450/450IS amplifiers can have their firmware remotely programmed using the Remote Diagnostics web interface. When amplifiers are being programmed, the system will not receive new amplifier diagnostics data until the programming is complete. From the Administration menu, click on the Amplifiers tab and then select the Smart Com 450 tab. This will display the 450 amplifier list in a table as shown below: C:\Workspace\...\help\help_en.xml page 51 of 56

52 The amplifier table displays the amplifier ID, Firmware version, Board Revision, the Last Report time, and whether the amplifier is currently in Programing Mode or not. When an amplifier is being programmed, it is put into Programming Mode and can only respond to programming commands and thus will not respond to requests for diagnostics data. If the firmware update fails or the serial connection is interruped, the amplifer will remain in Programming Mode until is successfully programmed. Amplfiers that are in Programming mode are highlighted in red: 1 Select amplifiers Select the amplifiers to be updated by clicking on the checkbox next the amplifier ID. You can select all amplifiers C:\Workspace\...\help\help_en.xml page 52 of 56

53 in the list by clicking the checkbox in the header. 2 Select new firmware file Click the Update Selected button and then browse your computer's file system for the new firmware file to be used. 3 Update firmware Click the Update button to begin updating the firmware on the selected amplifiers. The selected amplifiers will be updated sequentially. If the firmware update was successful, you will see the following screen: Chapter 14: System Settings To access the System Settings page, click on Admin and then the System tab. C:\Workspace\...\help\help_en.xml page 53 of 56

54 On this screen, you can change various system settings. Each of the fields are described below: Site name: The Site Name is usually set to the name of the mine or tunnel where the system is installed. This is displayed along the top of every screen. System type: The System Type box is used to select the type of Smart Com Leaky Feeder system that is installed. 150, 450 or 150 and 450 if both types of systems are installed. UDP port: 150/150IS only - The UDP port is the port on the server PC used to receive data from the DRX unit and should be left to the default value of 4322 unless there is a conflict with another application. DRX alarming: If checked, this option will set the DRX alarm state on/off depending on the alarm state of the diagnostics system. COM port: 450/450IS only - The COM port to use on the server for serial communications with the Head End. Baud rate: 450/450IS only - The baud rate to use for the serial connection to the Head End. Poll delay: 450/450IS only - This value controls how long the system waits between complete system polls. If there is a small number of amplifiers in the system, this value should be increased to reduce the amount of time the amplifier spends responding to diagnostics data requests. Poll timeout: 450/450IS only - This value determines how long the system should wait to get a response from an amplifier. If the server is connected to the Head End via serial-ethernet convertors for example, there can be a significant delay in communications, and the timeout value may need to be increased. Increasing this value will cause an increase in the time it takes to do a complete system refresh (retrieve data from all amplifiers in the system). C:\Workspace\...\help\help_en.xml page 54 of 56

55 Chapter 15: Printing In order to generate a printable list of amplifiers click on the Print icon below the Find Amplifier search box near the top of the page. This will display the amplifiers in a printer friendly layout. To print this page go to the browser's menu and click File, then Print. It is recommended that the page layout be set to landscape in order for all amplifier data to fit on the page. Chapter 16: Frequently Asked Questions (FAQs) How often will each amplifier report to the diagnostic receiver? Each Varis amplifier will report in to the diagnostic receiver approximately every 4-8 minutes. This default report time varies between amplifiers to minimize data loss through transmission collisions. Why are all amplifiers being reported as Unassigned? Varis (not MultiCOM) amplifiers automatically add themselves to the UNASSIGNED AMPLIFIERS branch when they first call in (See Configuring Amplifiers). What are the differences between Varis and MultiCOM amplifiers? MultiCOM amplifiers have AGC (Automatic Gain Control) in both the Forward (Down) and Return (Up) directions. A MultiCOM system usually generates a pilot in each amplifier at the end of a long branch (more than 6 amplifiers). The combination of several Return pilots ( MHz+/-100 khz) at splitters and at the Head End increases noise in the MHz band and significantly reduces signal to noise ratio, thereby reducing cable range (350 meters). Varis AGC amplifiers do not require the generation or maintenance of pilot tones. Varis amplifiers can be used to replace the "main trunk" of MultiCOM amplifiers and the MultiCOM amplifiers can be re-deployed on smaller branches. This has the following benefits: No pilot required in the "main trunk" reduces Return pilot noise. Varis 500 meter spacing means fewer amplifiers, less noise and greater range from the cable. Local Diagnostic LED's show system status immediately without special training or tools. More consistent amplification of channels as Varis' 15 MHz Bandpass is completely flat over the 2.4 MHz MultiCOM operating range. Why does the DRX Status show a warning icon even after configuring the DRX? If the DRX Status indicates there is no communication from the DRX ( check: ), there are a number of things you should Make sure the network cables are connected and/or not loose. Check that the DRX is correctly configured for the network. Use the ping command to verify that you can "see" the DRX from the web server. Verify that you entered the correct Web Server IP address on the DRX. If you have a firewall running on the web server or somewhere between the web server and the DRX, you must configure it to allow UDP packets through on port For example, in Windows XP, open the Windows Firewall dialog from the Control Panel. Click on the Exceptions tab, then the Add Port... button. For the Name, enter "Remote Diagnostics UDP" and for the Port Number, enter Also make sure you check the UDP radio button. Finally, click OK to save the changes. C:\Workspace\...\help\help_en.xml page 55 of 56

56 Chapter 17: Technical Support For more information about Varis' Remote Diagnostics please contact us at Varis - Smart Underground Communications 22 Brady Street, Unit 4 Sudbury,Ontario, Canada P3E 6E1 Tel: Fax: Toll free: Website: C:\Workspace\...\help\help_en.xml page 56 of 56

CI-218 / CI-303 / CI430

CI-218 / CI-303 / CI430 CI-218 / CI-303 / CI430 Network Camera User Manual English AREC Inc. All Rights Reserved 2017. l www.arec.com All information contained in this document is Proprietary Table of Contents 1. Overview 1.1

More information

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY 493456301 Rev B April 2009 Table of Contents Installation... 1 Setup... 2 Operation... 4 Live Video... 4 Video Settings... 5 Network

More information

SAT IF distribution system

SAT IF distribution system 7. Technical specifications Type cs43 RF input frequency range pr. 50-350 MHz inputs number 4 level pr. 55...88 dbµv 60...93 dbµv symbol rate 3 45 Ms/s return loss/impedance > 0 db/75 Ω LNB powering/control

More information

FS3. Quick Start Guide. Overview. FS3 Control

FS3. Quick Start Guide. Overview. FS3 Control FS3 Quick Start Guide Overview The new FS3 combines AJA's industry-proven frame synchronization with high-quality 4K up-conversion technology to seamlessly integrate SD and HD signals into 4K workflows.

More information

FS1-X. Quick Start Guide. Overview. Frame Rate Conversion Option. Two Video Processors. Two Operating Modes

FS1-X. Quick Start Guide. Overview. Frame Rate Conversion Option. Two Video Processors. Two Operating Modes FS1-X Quick Start Guide Overview Matching up and synchronizing disparate video and audio formats is a critical part of any broadcast, mobile or post-production environment. Within its compact 1RU chassis,

More information

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM. VideoJet 8000 8-Channel, MPEG-2 Encoder ARCHITECTURAL AND ENGINEERING SPECIFICATION Section 282313 Closed Circuit Video Surveillance Systems PART 2 PRODUCTS 2.01 MANUFACTURER A. Bosch Security Systems

More information

FS4 Quick Start Guide

FS4 Quick Start Guide FS4 Quick Start Guide Overview FS4 is AJA s flagship frame synchronizer and converter, offering incredible versatility and connectivity in a sleek and compact 1RU frame for all your 4K/ UltraHD/2K/HD/SD

More information

Installation & Operational Manual

Installation & Operational Manual Radiant Communications Corporation 5001 Hadley Road South Plainfield NJ 07080 Tel (908) 757-7444 Fax (908) 757-8666 WWW.RCCFIBER.COM QRF5000M MDU ENCODER Installation & Operational Manual Rev.A2 1. Introduction

More information

H.264 HDMI Extender over IP Extender With LED, Remote, POE, RS232 Operating Instruction

H.264 HDMI Extender over IP Extender With LED, Remote, POE, RS232 Operating Instruction H.264 HDMI Extender over IP Extender With LED, Remote, POE, RS232 Operating Instruction 1 Introduction This HDMI over IP Extender use the advanced H.264 as the compression type, which makes it occupy lower

More information

-TECH DIGITAL. Explore The High DefinitionWorld. Website: Hot Line: [US] USER MANUAL

-TECH DIGITAL. Explore The High DefinitionWorld. Website:  Hot Line: [US] USER MANUAL -TECH DIGITAL Explore The High DefinitionWorld Website: www.jtechdigital.com Hot Line: 1-888-610-2818[US] USER MANUAL J-Tech Digital ProAV H.264 Encoder/Decoder Many to Many HDMI Extender RoHS 1 Operating

More information

DVISm. DVISm - Mini Digital Video Insertion System. Quick Start Guide. Patent Pending

DVISm. DVISm - Mini Digital Video Insertion System. Quick Start Guide. Patent Pending DVISm Patent Pending DVISm - Mini Digital Video Insertion System Quick Start Guide Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make

More information

VIDEO GRABBER. DisplayPort. User Manual

VIDEO GRABBER. DisplayPort. User Manual VIDEO GRABBER DisplayPort User Manual Version Date Description Author 1.0 2016.03.02 New document MM 1.1 2016.11.02 Revised to match 1.5 device firmware version MM 1.2 2019.11.28 Drawings changes MM 2

More information

N+1 Redundancy with the VCom HD4040 Upconverter

N+1 Redundancy with the VCom HD4040 Upconverter N+1 Redundancy with the VCom HD4040 Upconverter Document ID: 47164 Contents Introduction Prerequisites Requirements Components Used Conventions Set Up Communication with the Upconverter VCom Dual4040D

More information

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual

HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual ZyCastR digi-mod HD Range digi-mod HD-1603 www.digi-modbyzycast.com HD-1603 Single Input MPEG-4 DVB-T HD Encoder/Modulator User Guide and Install Manual Table of Contents www.digi-modbyzycast.com Safety

More information

Wireless Studio. User s Guide Version 5.1x Before using this software, please read this manual thoroughly and retain it for future reference.

Wireless Studio. User s Guide Version 5.1x Before using this software, please read this manual thoroughly and retain it for future reference. 4-743-161-12 (1) Wireless Studio User s Guide Version 5.1x Before using this software, please read this manual thoroughly and retain it for future reference. DWR-R01D/R02D/R02DN/R03D 2018 Sony Corporation

More information

BY-HPE11KTA. Operating Instructions. Coaxial - LAN Converter with PoE function. Indoor Use Only. Model No. Attached Installation Guide

BY-HPE11KTA. Operating Instructions. Coaxial - LAN Converter with PoE function. Indoor Use Only. Model No. Attached Installation Guide Operating Instructions Coaxial - LAN Converter with PoE function Model No. Indoor Use Only BY-HPE11KTA Attached Installation Guide Before attempting to connect or operate this product, please read these

More information

Positive Attendance. Overview What is Positive Attendance? Who may use Positive Attendance? How does the Positive Attendance option work?

Positive Attendance. Overview What is Positive Attendance? Who may use Positive Attendance? How does the Positive Attendance option work? Positive Attendance Overview What is Positive Attendance? Who may use Positive Attendance? How does the Positive Attendance option work? Setup Security Codes Absence Types Absence Reasons Attendance Periods/Bell

More information

EEG A1452 SCTE-104 Inserter Frame Card

EEG A1452 SCTE-104 Inserter Frame Card EEG A1452 SCTE-104 Inserter Frame Card Product Manual EEG Enterprises, Inc. 586 Main Street Farmingdale, New York 11735 TEL: (516) 293-7472 FAX: (516) 293-7417 Copyright EEG Enterprises, Inc. 2017 All

More information

Z-IP Stream 004/008. User Guide and Installation Manual. Four or Eight Input QAM Encoder / Modulator

Z-IP Stream 004/008. User Guide and Installation Manual. Four or Eight Input QAM Encoder / Modulator Z-IP Stream 004/008 User Guide and Installation Manual Four or Eight Input QAM Encoder / Modulator MPEG-2 / H.264 HD ENCODER with QAM /IP/ & ASI Outputs Contents Safety Precautions... 3 Package Contents...

More information

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart. Saab TransponderTech AB. Appendices. Project designation. Document title. Page 1 (25)

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart. Saab TransponderTech AB. Appendices. Project designation. Document title. Page 1 (25) Appendices 1 (25) Project designation R5 RIC Document title CONTENTS 2 (25) 1 References... 4 2 Dimensions... 5 3 Connectors... 6 3.1 Power input... 6 3.2 Video I... 6 3.3 Video Q... 6 3.4 Sync... 6 3.5

More information

innovative technology to keep you a step ahead 24/7 Monitoring Detects Problems Early by Automatically Scanning Levels and other Key Parameters

innovative technology to keep you a step ahead 24/7 Monitoring Detects Problems Early by Automatically Scanning Levels and other Key Parameters 24/7 Monitoring Detects Problems Early by Automatically Scanning Levels and other Key Parameters Issues SNMP Traps to Notify User of Problems Ability for Remote Control Lets Users Take a Closer Look Without

More information

Agilis Fiber Optic Transceiver AFOT Series

Agilis Fiber Optic Transceiver AFOT Series Agilis Fiber Optic Transceiver AFOT Series Installation and Operation Manual IM02960225 Rev. B Copyright Notice All information contained in this Manual are the property of ST Electronics (Satcom & Sensor

More information

Noise Detector ND-1 Operating Manual

Noise Detector ND-1 Operating Manual Noise Detector ND-1 Operating Manual SPECTRADYNAMICS, INC 1849 Cherry St. Unit 2 Louisville, CO 80027 Phone: (303) 665-1852 Fax: (303) 604-6088 Table of Contents ND-1 Description...... 3 Safety and Preparation

More information

Dragon. manual version 1.6

Dragon. manual version 1.6 Dragon manual version 1.6 Contents DRAGON TOP PANEL... 2 DRAGON STARTUP... 2 DRAGON STARTUP SCREEN... 2 DRAGON INFO SCREEN... 3 DRAGON MAIN SCREEN... 3 TURNING ON A TRANSMITTER... 4 CHANGING MAIN SCREEN

More information

CCE900-IP-TR. User s Guide

CCE900-IP-TR. User s Guide CCE900-IP-TR CCE900-IP-T & CCE900-IP-R User s Guide i-tech Company LLC TOLL FREE: (888) 483-2418 EMAIL: info@itechlcd.com WEB: www.itechlcd.com 1. Introduction The CCE900-IP-T & CCE900-IP-R is a solution

More information

VNS2200 Amplifier & Controller Installation Guide

VNS2200 Amplifier & Controller Installation Guide VNS2200 Amplifier & Controller Installation Guide VNS2200 Amplifier & Controller Installation 1. Determine the installation location for the VNS2200 device. Consider the following when determining the

More information

GV-3D People Counter 3DPCV10-A

GV-3D People Counter 3DPCV10-A GV-3D People Counter User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 3DPCV10-A 2013 GeoVision, Inc. All

More information

Package Contents. LED Protocols Supported. Safety Information. Physical Dimensions

Package Contents. LED Protocols Supported. Safety Information. Physical Dimensions Pixel Triton Table of Contents Package Contents... 1 Safety Information... 1 LED Protocols Supported... 1 Physical Dimensions... 1 Software Features... 2 LED Status... 2 Power... 2 Activity LED... 2 Link

More information

MS2540 Current Loop Receiver with RS485 Communication

MS2540 Current Loop Receiver with RS485 Communication MS2540 Current Loop Receiver with RS485 Communication User Manual Metal Samples Company A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358 4202 Fax:

More information

Video Server SED-2100R/S. Quick Installation Guide

Video Server SED-2100R/S. Quick Installation Guide Video Server SED-2100R/S Quick Installation Guide Feb.10,2006 1 1 Getting Started 1.1 PACKAGE CONTENTS SED-2100 Warranty Card Software CD Hook up & Screws Terminal Blocks for Power & DI/O Power Adaptor

More information

QRF5000 MDU ENCODER AND QAM MODULATOR

QRF5000 MDU ENCODER AND QAM MODULATOR Radiant Communications Corporation 5001 Hadley Road South Plainfield NJ 07080 Tel (908) 757-7444 Fax (908) 757-8666 WWW.RCCFIBER.COM QRF5000 MDU ENCODER AND QAM MODULATOR Installation & Operational Manual

More information

Quick Operation Guide of LTN7700/7600 Series NVR

Quick Operation Guide of LTN7700/7600 Series NVR Quick Operation Guide of LTN7700/7600 Series NVR UD.6L0202B0042A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable

More information

Instruction Manual Model Block Up/Downconverter

Instruction Manual Model Block Up/Downconverter Instruction Manual Model 4117-14 Block Up/Downconverter Weather Resistant Unit March 2017, Rev. J Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may

More information

VS-TV. User manual. Virtual Matrix ENGLISH

VS-TV. User manual. Virtual Matrix ENGLISH ENGLISH VS-TV User manual Virtual Matrix INDEX 1 INTRODUCTION... 2 1.1 FEATURES.... 2 2 INSTALLATION AND SET UP... 3 2.1 UNIT PACKAGE CONTENTS... 3 2.2 INSTALLATION... 3 2.3 UNIT SET UP... 3 3 CONFIGURATION

More information

BRIGHTLINK HDMI EXTENDER OVER ETHERNET - H METER MODEL: BL-EXT-IP-264

BRIGHTLINK HDMI EXTENDER OVER ETHERNET - H METER MODEL: BL-EXT-IP-264 BRIGHTLINK HDMI EXTENDER OVER ETHERNET - H.264-120 METER MODEL: BL-EXT-IP-264 Operating Instructions BRIGHTLINKAV.COM 1 Introduction This HDMI over IP Extender use the advanced H.264 as the compression

More information

Manual Version Ver 1.0

Manual Version Ver 1.0 The BG-3 & The BG-7 Multiple Test Pattern Generator with Field Programmable ID Option Manual Version Ver 1.0 BURST ELECTRONICS INC CORRALES, NM 87048 USA (505) 898-1455 VOICE (505) 890-8926 Tech Support

More information

User manual Transmodulators. Ref. 5103S/5103T/5103Q/5130

User manual Transmodulators. Ref. 5103S/5103T/5103Q/5130 User manual Transmodulators Ref. 5103S/5103T/5103Q/5130 Contents 1 Introduction 2 1.1 The ProQuad range................................ 2 1.2 Modular system solution.............................. 4 1.3

More information

Operation and Installation Guide

Operation and Installation Guide Operation and Installation Guide HDS2800 Series Encoder Modulator High Definition (HD) Digital COFDM MPEG2 and H.264 Modulator with IP Multicast. 19 Rack Mount Revision 4.0 Firmware version Released File

More information

Network Camera Operating Manual

Network Camera Operating Manual Network Camera Operating Manual Model No. WV-NW484S Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. Preface About these

More information

QUICK START GUIDE QT ANALOG HD CAMERA & DVR BUNDLE ENGLISH

QUICK START GUIDE QT ANALOG HD CAMERA & DVR BUNDLE ENGLISH QUICK START GUIDE QT ANALOG HD CAMERA & DVR BUNDLE ENGLISH Table of Contents Welcome What s Included...3 Understanding your DVR...4 Get Connected Registration...5 Connect Your Cameras...5 Connect DVR to

More information

Rack-Mount Receiver Analyzer 101

Rack-Mount Receiver Analyzer 101 Rack-Mount Receiver Analyzer 101 A Decade s Worth of Innovation No part of this document may be circulated, quoted, or reproduced for distribution without prior written approval from Quasonix, Inc. Copyright

More information

HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L

HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L HD4112 Quad HDMI MPEG2 HD DVBT Encoder Modulator U S E R M A N U A L HD4112 Manual Rev 1 Contents 1. GENERAL 1.1 Description 1.2 Specifications 2. INSTALLATION 2.1 What s in the Box 2.2 Connection 2.2.1

More information

VNS2210 Amplifier & Controller Installation Guide

VNS2210 Amplifier & Controller Installation Guide VNS2210 Amplifier & Controller Installation Guide VNS2210 Amplifier & Controller Installation 1. Determine the installation location for the VNS2210 device. Consider the following when determining the

More information

SNG-2150C User s Guide

SNG-2150C User s Guide SNG-2150C User s Guide Avcom of Virginia SNG-2150C User s Guide 7730 Whitepine Road Revision 001 Richmond, VA 23237 USA GENERAL SAFETY If one or more components of your earth station are connected to 120

More information

QUICK START GUIDE. QT Analog HD Camera & DVR Bundle ENGLISH

QUICK START GUIDE. QT Analog HD Camera & DVR Bundle ENGLISH QUICK START GUIDE QT Analog HD Camera & DVR Bundle ENGLISH Table of Contents Welcome What s Included...3 Understanding your DVR...4 Get Connected Registration...5 Connect Your Cameras...5 Connect DVR to

More information

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide DS-7200HVI/HFI-SH Series DVR Quick Operation Guide UD.6L0202B0019A01 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is

More information

Laboratory stand description. Investigation of DVB-T/C/IPTV technologies

Laboratory stand description. Investigation of DVB-T/C/IPTV technologies 1 Laboratory stand description Investigation of DVB-T/C/IPTV technologies Table of Contents 1. Hardware prerequisites... 3 1.1 Hardware parts... 3 1.2 Cables required for system interconnection... 5 1.3

More information

Projector Management Application Version 7.00 Instruction Guide

Projector Management Application Version 7.00 Instruction Guide Projector Management Application Version 7.00 Instruction Guide Contents 1 INTRODUCTION... 4 1.1 OUTLINE... 4 1.2 SYSTEM... 4 2 INSTALLATION... 5 2.1 SYSTEM REQUIREMENTS... 5 2.2 PROJECTOR MANAGEMENT APPLICATION

More information

Instruction Manual Model 2412-x08 Multi-Channel AGC Amplifier

Instruction Manual Model 2412-x08 Multi-Channel AGC Amplifier Instruction Manual Model 2412-x08 Multi-Channel AGC Amplifier 2412-408 Four Channel 2412-308 Three Channel 2412-208 Two Channel 2412-108 One Channel March 2017, Rev. A 1 2 3 4 A B CHANNEL STATUS REMOTE

More information

Overview. Shipped in the Venue Vizion Package: Simplified Integration Process. Installation consists of 6 easy steps:

Overview. Shipped in the Venue Vizion Package: Simplified Integration Process. Installation consists of 6 easy steps: Overview Shipped in the Venue Vizion Package: Four two-channel QMOD Encoder-Modulators Each unit can accept up to 2 inputs, providing up to 8 channels in the system. One ICE-HE-DXL Display Control Center

More information

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters Written By: Colin Langridge Issue: Draft Date: 03 rd July 2008 1 Date: 29 th July 2008 2 Date: 20 th August 2008 3 Date: 02 nd

More information

MyM Pro 3S/6S Installation guide

MyM Pro 3S/6S Installation guide MyM Pro 3S/6S Installation guide CONTENT 1. Introduction 2. Unpacking the unit 3. Connections and indications 4. IP settings 5. Menus and settings web ui 5.1 Overview menu 5.2 Input settings 5.3 Output

More information

Digital Video Recorder

Digital Video Recorder Digital Video Recorder Quick Operation Guide UD.6L0202B0067A02 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable

More information

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/ 11/6/2009 www.elber.com elber@elber.it TCU/RCU RF Head Control Units User Manual Elber s.r.l.- Via Pontevecchio, 42W Phone +39-0185.35.13.33 16042 Carasco (GE) Italy Fax +39-0185.35.13.00 1 Sommario 2

More information

INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM

INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM ATTENTION: READ THE ENTIRE INSTRUCTION SHEET BEFORE STARTING THE INSTALLATION PROCESS. WARNING! Do not begin to install your

More information

Amb-OS Media, LLC AMR-100

Amb-OS Media, LLC AMR-100 Amb-OS Media, LLC AMR-100 Operations Manual Firmware 2.30 Revision 41 03/11/15 SUPPORT INFORMATION Email: support@amb-os.com Phone 877AMBOS2U (877) 262-6728 AMB-OS WEB PAGE for program downloads, RSS feed

More information

Scan Converter Installation Guide

Scan Converter Installation Guide Scan Converter Installation Guide Software on supplied disks Please note: The software included with your scan converter is OPTIONAL. It is not needed to make the scan converter work properly. This software

More information

Single cable multiswich programmer PC102W

Single cable multiswich programmer PC102W Single cable multiswich programmer PC102W 1. Product description The PC102W - single cable multiswich programmer (in the text - programmer) is useful instrument while configuring and troubleshooting SAT

More information

HD168Bi Quad CVBS/HDMI HD DVBT Encoder Modulator U S E R M A N U A L

HD168Bi Quad CVBS/HDMI HD DVBT Encoder Modulator U S E R M A N U A L HD168Bi Quad CVBS/HDMI HD DVBT Encoder Modulator U S E R M A N U A L Contents 1. GENERAL 1.1 Description 1.2 Specifications 2. INSTALLATION 2.1 What s in the Box 2.2 Connection 2.2.1 DEVICE Programming

More information

Model 1476-C SuperQuad HR

Model 1476-C SuperQuad HR Model 1476-C SuperQuad HR Installation and Operating Instructions Table of Contents Page Table of Content... 2 System Description... 3 Features... 3 Installation... 4 Internal Setups... 4 Connections...

More information

BecauseRFL andhubbel haveapolicyofcontinuousproductimprovement,wereservetherighttochangedesignsandspecificationswithoutnotice.

BecauseRFL andhubbel haveapolicyofcontinuousproductimprovement,wereservetherighttochangedesignsandspecificationswithoutnotice. 1. Introduction 1.1 Overview The RFL VS800 CODEC enables high quality video transmission combined with voice and data over E1 (2.048Mbit/s), T1 (1.55Mbit/s) or Ethernet links. This provides an alternative

More information

DTV744 Installation Quick Start Guide

DTV744 Installation Quick Start Guide DTV744 Installation Quick Start Guide The Wegener Model DTV744 8VSB 4-Channel Demodulator receives VHF/UHF broadcast HDTV 8VSB signals and provides output ASI streams for connection to an advanced cable

More information

DTV742 Installation Quick Start Guide

DTV742 Installation Quick Start Guide DTV742 Installation Quick Start Guide The Wegener Model DTV742 8VSB 4-Channel Multiplexor receives VHF/UHF broadcast HDTV signals and provides output ASI streams for connection to cable system QAM modulators.

More information

User Manual. UNIVERSE Ref. 8600

User Manual. UNIVERSE Ref. 8600 User Manual UNIVERSE Ref. 8600 No part of this manual may be copied, reproduced, transmitted, transcribed or translated into any language without permission. Unitron reserves the right to change the specifications

More information

Remote Application Update for the RCM33xx

Remote Application Update for the RCM33xx Remote Application Update for the RCM33xx AN418 The common method of remotely updating an embedded application is to write directly to parallel flash. This is a potentially dangerous operation because

More information

SD4650 DVB-T HD MODULATOR. User Manual

SD4650 DVB-T HD MODULATOR. User Manual SD4650 DVB-T HD MODULATOR User Manual 0 TABLE OF CONTENT 1 GENERAL...2 1.1 Description...2 1.2 Specifications...3 2 INSTALLATION...4 2.1 What s in the Box...4 One power cable...4 2.2 Connection...4 2.2.1

More information

DM1624, DM1612, DM812

DM1624, DM1612, DM812 Installation Guide Hardware and Software DM Series Digital Processors models DM1624, DM1612, DM812 LECTROSONICS, INC. 1 Installation Specific Information Only This guide covers only installation related

More information

MyM-3S Micro Master. Installation Guide. English. design for TV

MyM-3S Micro Master. Installation Guide. English. design for TV MyM-3S Micro Master Installation Guide design for TV 1 CONTENT 1. Introduction 2. Unpacking the unit 3. Connections and indications 4. IP settings 5. Menus and settings 5.1 Overview menu 5.2 Input settings

More information

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

FCPM-6000RC. Mini-Circuits  P.O. Box , Brooklyn, NY (718) USB / Ethernet Integrated Frequency Counter & Power Meter 50Ω -30 dbm to +20 dbm, 1 MHz to 6000 MHz The Big Deal Automatically synchronized power & frequency measurements USB and Ethernet control Includes

More information

Video Extender DS128 DSRXL. Instruction Manual. 8-Port Cat5 VGA Digital Signage Broadcaster with RS232 and Audio

Video Extender DS128 DSRXL. Instruction Manual. 8-Port Cat5 VGA Digital Signage Broadcaster with RS232 and Audio DS128 DSRXL Instruction Manual Video Extender 8-Port Cat5 VGA Digital Signage Broadcaster with RS232 and Audio Cat5 VGA Digital Signage Receiver with RS232 and Audio FCC Compliance Statement This equipment

More information

Instruction Manual Model Upconverter

Instruction Manual Model Upconverter Instruction Manual Model 2015-02 Upconverter July 2014, Rev. P F=1525 G=+00.0 MENU MODEL 2015 UPCONVERTER CROSS TECHNOLOGIES INC. REMOTE POWER MUTE ALARM EXECUTE Data, drawings, and other material contained

More information

REVISIONS LTR DESCRIPTION DATE APPROVED - Initial Release 11/5/07 MDB A ECR /9/08 MDB

REVISIONS LTR DESCRIPTION DATE APPROVED - Initial Release 11/5/07 MDB A ECR /9/08 MDB REVISIONS LTR DESCRIPTION DATE APPROVED - Initial Release 11/5/07 MDB A ECR 8770 4/9/08 MDB CONTRACT NO. DRAWN BY CHECKED BY APPROVED BY DATE P. Phillips 11/2/07 TITLE M. Bester 11/5/07 SIZE A 2120 Old

More information

CompactMax-2 DVB-S/S2 TO DVB-T2 TRANSMODULATOR - 0 MI2100 -

CompactMax-2 DVB-S/S2 TO DVB-T2 TRANSMODULATOR - 0 MI2100 - CompactMax-2 DVB-S/S2 TO DVB-T2 TRANSMODULATOR - 0 MI2100 - SAFETY NOTES Read the user s manual before using the equipment, mainly "SAFETY RULES" paragraph. The symbol on the equipment means "SEE USER

More information

User s Manual. Network Board. Model No. WJ-HDB502

User s Manual. Network Board. Model No. WJ-HDB502 Network Board User s Manual Model No. WJ-HDB502 Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. CONTENTS Introduction...

More information

RF Mogul. Quick Start. Model: SDC1. Satellite Dish Controller

RF Mogul. Quick Start. Model: SDC1. Satellite Dish Controller RF Mogul Satellite Dish Controller Model: SDC1 Quick Start 29 February 2012 Minimum required hardware to find a Satellite! This Quick Start document is for connecting and operating a General Dynamics C125M

More information

DINOX&Digital&Video&Recorder&

DINOX&Digital&Video&Recorder& DINOX&Digital&Video&Recorder& & & & & & & & & & &&&Quick&Operation&Guide& UD.7L0X02B1228B01& Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact

More information

INFORMATION TO USER CAUTION RISK OF ELECTRIC SHOCK, DO NOT OPEN

INFORMATION TO USER CAUTION RISK OF ELECTRIC SHOCK, DO NOT OPEN INFORMATION TO USER CAUTION RISK OF ELECTRIC SHOCK, DO NOT OPEN! CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED

More information

Matrox PowerStream Plus

Matrox PowerStream Plus Matrox PowerStream Plus User Guide 20246-301-0100 2016.12.01 Contents 1 About this user guide...5 1.1 Using this guide... 5 1.2 More information... 5 2 Matrox PowerStream Plus software...6 2.1 Before you

More information

Video Micro Converter

Video Micro Converter Setup Manual www.ecue.com e:cue lighting control An OSRAM Company Rev. 20101125 Contents Device Overview....................................... 4 About the Video Micro Converter...............................

More information

Syntor X Flash Memory Module Revision C

Syntor X Flash Memory Module Revision C Syntor X Flash Memory Module Revision C The PIEXX SynXFlash memory module, along with the supplied PC software, replaces the original SyntorX code plugs and allows you to easily set modify and update your

More information

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION DA-3G CONNECTIONS SPECIFICATIONS SERIAL VIDEO INPUT...

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION DA-3G CONNECTIONS SPECIFICATIONS SERIAL VIDEO INPUT... TABLE OF CONTENTS 1. OVERVIEW... 1 2. INSTALLATION... 3 2.1. 500DA-3G CONNECTIONS... 3 3. SPECIFICATIONS... 4 3.1. SERIAL VIDEO INPUT... 4 3.2. SERIAL VIDEO OUTPUT... 4 3.3. ELECTRICAL... 4 3.4. PHYSICAL...

More information

DETEXI Basic Configuration

DETEXI Basic Configuration DETEXI Network Video Management System 5.5 EXPAND YOUR CONCEPTS OF SECURITY DETEXI Basic Configuration SETUP A FUNCTIONING DETEXI NVR / CLIENT It is important to know how to properly setup the DETEXI software

More information

TV4U QUAD DVB-S2 to DVB-C TRANSMODULATOR

TV4U QUAD DVB-S2 to DVB-C TRANSMODULATOR INSTRUCTION MANUAL Features of the new DVB-C transmodulators line Through the use of the FPGA technology the transmodulators provides the highest performance at the lowest price. Four carriers are formed

More information

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1.

ivw-fd122 Video Wall Controller MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Page i Rev. 1. MODEL: ivw-fd122 Video Wall Controller Supports 2 x 2 Video Wall Array User Manual Rev. 1.01 Page i Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice

More information

IP LIVE PRODUCTION UNIT NXL-IP55

IP LIVE PRODUCTION UNIT NXL-IP55 IP LIVE PRODUCTION UNIT NXL-IP55 OPERATION MANUAL 1st Edition (Revised 2) [English] Table of Contents Overview...3 Features... 3 Transmittable Signals... 3 Supported Networks... 3 System Configuration

More information

H.264 HDMI Extender over IP Extender With LED, Remote, POE, RS232 WolfPack Operating Instruction

H.264 HDMI Extender over IP Extender With LED, Remote, POE, RS232 WolfPack Operating Instruction H.264 HDMI Extender over IP Extender With LED, Remote, POE, RS232 WolfPack Operating Instruction 1 Introduction This WolfPack HDMI over IP Extender use the advanced H.264 as the compression type, which

More information

AV Foundry VideoForge HDMI Digital Video Generator Quick Start Guide

AV Foundry VideoForge HDMI Digital Video Generator Quick Start Guide AV Foundry VideoForge HDMI Digital Video Generator Quick Start Guide Thank you for purchasing an AV Foundry VideoForge HDMI Digital Video Generator, a versatile, high value test pattern generator with

More information

LedSet User s Manual V Official website: 1 /

LedSet User s Manual V Official website:   1 / LedSet User s Manual V2.6.1 1 / 42 20171123 Contents 1. Interface... 3 1.1. Option Menu... 4 1.1.1. Screen Configuration... 4 1.1.1.1. Instruction to Sender/ Receiver/ Display Connection... 4 1.1.1.2.

More information

OPERATORS & INSTALLATION MANUAL JOTRON AIS VIEWER WINDOWS PC SOFTWARE

OPERATORS & INSTALLATION MANUAL JOTRON AIS VIEWER WINDOWS PC SOFTWARE OPERATORS & INSTALLATION MANUAL JOTRON AIS VIEWER WINDOWS PC SOFTWARE AMENDMENT RECORD AMENDMENT NO. INCORP. BY DATE PAGE(S) VERSION CHANGE NOTE ( EM) 1 ES 06.10.2004 29 A 2 ES 04.03.2005 29 B Included

More information

The Art of Engineering

The Art of Engineering The Art of Engineering Functionality DPST Switch DPST Sensing Switch Transfer Switch Passive Splitter Ethernet Switch ASI 3G Switch or DA E/T Switch Optical Switch up to 006 MHz L-Band Broadband Ethernet

More information

OTX Optical Transmitter. Operation Instructions

OTX Optical Transmitter. Operation Instructions OTX 1310-10 Optical Transmitter Operation Instructions Operation Instructions OTX 1310-10 Optical Transmitter Table of contents 1. Description...4 1.1. Block Diagram...4 2. Front and rear panel...5 2.1.

More information

The Diverse Multimedia & Surveillance System Via Dico2000 with PC DICO Operation Manual

The Diverse Multimedia & Surveillance System Via Dico2000 with PC DICO Operation Manual DICO 2000 Operation Manual Main Screen Overview IP Address & Communication Status Disk Status Screen Mode Warning Status Video Recording Status RUN Setup Search Exit SETUP The beginning ID and Password

More information

Intelligent Security and Fire Ltd

Intelligent Security and Fire Ltd User Manual Product ranges covered by this manual Vi-P14 Vi-P14A Document Reference Date Firmware Vi-Q4C1 Viq601a.doc 26/11/2009 From Viq001a21 Videoswitch Telephone 01252-851510 Ocean House, Redfields

More information

First Time Setup Guide

First Time Setup Guide First Time Setup Guide www.exhibio.com 1.877.EXHIBIO (394.4246) Exhibio ST-200 Components & Accessories Standing Mount TV Tuner with Input Cable (USB 2.0 only) VESA Mount Over-the-Air Antenna Power Adapter

More information

Instruction Manual Model

Instruction Manual Model Instruction Manual Model 4115-267 Ka-Band Block Upconverter May 2015, Rev. C Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated

More information

User s Manual HDMI Modulator ATSC 8VSB/QAM 65/256. Model No : HDM100

User s Manual HDMI Modulator ATSC 8VSB/QAM 65/256. Model No : HDM100 User s Manual HDMI Modulator ATSC 8VSB/QAM 65/256 Model No : HDM100 Contents 1. Safety Instructions & Precautions. 1 2. Operation Guide.. 2 2-1. Connection Diagram. 2 2-2. Front Panel.... 3 2-3. Rear Panel.....

More information

Specifications XTP CrossPoint 1600 and XTP CrossPoint 3200 Series

Specifications XTP CrossPoint 1600 and XTP CrossPoint 3200 Series Specifications XTP CrossPoint 1600 and XTP CrossPoint 3200 Series Video input XTP CP 4i, XTP CP 4i DMA Number/signal type... 4 sets of proprietary twisted pair AV signals Connectors... 4 female RJ-45 per

More information

Hardware Setup. If you have any further questions after checking this document, please contact

Hardware Setup. If you have any further questions after checking this document, please contact Hardware Setup If you have any further questions after checking this document, please contact support@cognisens.com Hardware Setup Getting Started: NeuroTracker Pro WHAT TO BUY SETTING UP YOUR 3D TV SETTING

More information

DVIS. DVIS - Digital Video Insertion System. Quick Start Guide. Patent Pending

DVIS. DVIS - Digital Video Insertion System. Quick Start Guide. Patent Pending DVIS Patent Pending DVIS - Digital Video Insertion System Quick Start Guide Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments

More information

CompactMax-4 DVB-S/S2 TO ISDB-T TRANSMODULATOR - 0 MI2101 -

CompactMax-4 DVB-S/S2 TO ISDB-T TRANSMODULATOR - 0 MI2101 - CompactMax-4 DVB-S/S2 TO ISDB-T TRANSMODULATOR - 0 MI2101 - SAFETY NOTES Read the user s manual before using the equipment, mainly "SAFETY RULES" paragraph. The symbol on the equipment means "SEE USER

More information