Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:
|
|
- Arleen O’Neal’
- 5 years ago
- Views:
Transcription
1 Theatre SPECIFICATIONS UPDATED: 13/08/13 ADDRESS: 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: TECHNICAL MANAGER: E MAIL: JAKE SUTTON JAKES@LIGHTHOUSEPOOLE.CO.UK GENERAL MANAGER: E MAIL: RACHEL NEWMAN RACHELN@LIGHTHOUSEPOOLE.CO.UK Theatre Specs Updated 13/08/13 This Document Is Updated Every 12 Months
2 THE THEATRE 669 Seats in one continuous rake, including provision of 10 wheelchair positions at the front of the auditorium and a further 6 at the rear. AUDITORIUM When Orchestra Pit/Forestage are in use the capacity is reduced by 17 (652 seats) and the wheelchair provision by 4 (6 Positions) *If orchestra pit / forestage are required notice is required before the production is put on sale at the ticket office. Stage material: hardwood strip covered by 12mm MDF (black harlequin vinyl dance floor available) Proscenium opening: Width Height 9900mm 5400mm STAGE Stage width: between fly floors 19800mm 13899mm Stage depth: setting line to back wall front of stage to setting line Stage height: to grid flying height under fly floors 9144mm 1372mm 13599mm 13259mm 8499mm Forestage: 9900mm x 3798mm maximum at centre line. FLYING 36 single purchase counterweight sets 3 hemp sets Flying bars 13158mm long, operated from S/L fly floor. House Tabs operated from floor level PS *For rigging information please contact technical manager. see page 6 for hanging plot 2
3 ORCHESTRA PIT Forestage lowers 2800mm below stage level to meet rear pit (under stage) giving maximum size of 9900mm x 3798mm at centre line. Capacity 25 musicians. 1 x Conductor & 4 x lit music stands. Working (Prompt) corner - portable on 3m extension for use either Down Stage P.S or Down Stage O.P STAGE MANAGER F.O.H. & R.O.H Paging system All dressing rooms have show relay Communication to all venue areas is supplied by a 6 pin talk back system (cans) and cue lights GET IN WARDROBE At tailboard height direct to stage U/S OP via scene Dock Doors 2400mm wide x 3399mm high Inner Doors: Bi Folding and single door Outside: Electric roller door See Below For image Below stage Dressing Room level fitted with automatic washing machine, tumble drier, steam iron and ironing board. DRESSING ROOMS Stage level Below Stage 4 rooms each for 3 to 4 persons (with showers) 1 room either Company Office with private telephone line (metered) or extra dressing room for 2 to 3 persons 2 Band/Chorus Rooms for approx 10 persons 4 rooms each for 3 to 4 persons (with showers) 1 room for 2 to 3 persons Lift & Stairs connects dressing room and stage door levels (In the same room) 1 x Disabled toilet & shower on each floor 3
4 House Tabs Burgundy Velour 12000mm x 6000mm Masking 10x black wool serge legs 6x straight borders 1x split black 7500mm x 3000mm 13000mm x 3000mm 13000mm x 7500mm STAGE DRAPES 1x full black 13000mm x 7500mm Gauze 2x black 13000mm x 7500mm 1x light grey 13000mm x 7500mm Star cloth 1x star cloth 13000mm x 7500mm Hard Masking 2 black wool serge covered flats 4 black wool serge covered flats 6000mm x 1900mm 6000 x 1220mm SOUND Midas Venice desk with Peavey media matrix supplying routing, equalization and limited effects. With 9x Mackie MC2600 Amps supplying to house PA via 2 Tannoy S300 in central cluster above pros, 2 Tannoy S300 left and right of pros, 6 JBL control 1 front fills fitted to stage front, 6 JBL control 1 delays to rear of stalls, 2 Tannoy B950 subs left and right of pros (at stage level) 2x stage fold back speaker cabinets.2x 5m58 switch mics with stands and cables, 2x mono di boxes with cables and 1x CD or mini disc player. Quadreverb effects unit. Operable from either on stage or open booth at rear of auditorium. Reference recording service available, please contact technical manager for details. *Extra equipment is available, please contact technical manager for details. 4
5 Control Dimmers ETC, Expression 3 in control room at rear of auditorium or can be moved to either stage or center auditorium for rehearsal. Riggers control can be inserted onstage, FOH, perches or fly floors. 220x 3kw & 12x 6kw by ETC sensor dimmers Lanterns 54x Parcan 1kw With CP62 lamps (61 and 60 lamps available upon request) 24x Selecon 1kw Fresnel c/w Barn Doors 20x Strand 743 1kw Fresnel c/w barn doors 04x Strand 243 2kw Fresnel c/w barn doors 16x Thomas 4 cell 1kw 14x ETC Source 4 19 profile (fixed FOH Bridge 2) 08x ETC Source 4 36 profile 12x Strand SL 15/32 profile 06x Strand SL 23/50 profile 06x ETC Source 4 Jr 50 Profiles ELECTRICS 2x Theatre 1kw follow spots (fixed FOH on Bridge 2) *Extra equipment is available; please contact technical manager for details. Aux power 2x 200amp x 3 phase supply situated DSR (Powerlock connectors). 1x 125a 3phase Cform DSR 1x 63a 1phase Cform DSR 1x 63a 3phase Cform DSR 2x 32a 1phase Cform DSR 1x32a 3phase Cform DSR 32amp x 1 phase supply situated up stage left (Cform connector) *We do not hold connectors for all Cform values; Please contact Technical Manager for details FOH LIGHTING POSITIONS 1 st & 2 nd. Bridge, 4m & 9m from front edge of stage and 8m above (Approx. See Plan for Details) stage level. Pros booms d/s of pros arch and further variable positions available at side of auditorium. Parking There are spaces for 4 cars on our theatre car park Please contact technical manager if this is insufficient. Please do not park in the loading bays 5
6 LIGHTHOUSE, Poole s Centre for the Arts THEATRE HANGING PLOT front of stage to back of safety curtain 800mm BAR NO Dist. From safety curt DESCRIPTION FLYING NOTES 1 200mm c/w House Tabs 2 370mm Hemp House Border 3 660mm c/w mm c/w mm c/w mm c/w mm c/w mm c/w mm c/w 11 NOT AVAILABLE mm c/w mm c/w mm c/w mm c/w mm c/w mm c/w mm c/w 19 NOT AVAILABLE mm c/w mm c/w 22 NOT AVAILABLE mm c/w 24 NOT AVAILABLE mm c/w 26 NOT AVAILABLE mm c/w mm c/w mm c/w mm c/w mm c/w mm c/w mm c/w 34 NOT AVAILABLE mm c/w mm c/w mm c/w mm c/w mm c/w mm c/w mm c/w mm c/w mm c/w mm c/w to back wall 9740mm 6
7 Theatre: Plan & Bar Positions Theatre Specs Updated 13/08/13 This Document Is Updated Every 12 Months
8 Theatre: Side Elevation & Bar Positions 8
9 Dock Door Locations As we have multiple venues Within our building there are Several dock doors, this shows Where they are located on The building 9
10 The Theatre Dock Door The dock door is on a ramp, and can be difficult to get up, however if you follow the blue line painted on the floor, it will make the reversing & parking a lot easier. Theatre Specs Updated 13/08/13 This Document Is Updated Every 12 Months
SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.
TECHNICAL INFORMATION MAIN HOUSE STAGE DIMENSIONS The main stage is a flat floor sprung hardboard stage with a proscenium opening of 10.5m x 9.1m depth. The proscenium height is variable by the house border
More informationTheatre Technical Specifications
The Esplanade, Weymouth, Dorset, DT4 8ED 01305 783225 Theatre Technical Specifications Created by David Tozer, Technical Manager. dave@weymouthpavilion.com 1 of 10 Updated November 2015 The Theatre The
More informationNew Theatre Royal Lincoln Technical Information
1 New Theatre Royal Lincoln Technical Information Please note that some items on our tech spec are subject to a recharge. Please contact Steve Chambers the Technical Manager on 07985 275522 or email technical@newtheatreroyallincoln.com
More informationDEREHAM MEMORIAL HALL
DEREHAM MEMORIAL HALL is a multi purpose venue incorporating a 294 seat proscenium arch theatre. A standard stage, lighting and sound rig as set out below will be provided, unless otherwise agreed. Any
More informationThe Haymarket Basingstoke Technical Specifications
The Haymarket Basingstoke Technical Specifications The Haymarket Wote Street Basingstoke Hampshire RG21 7NW 01256 819797 Administration 01256 844244 Box office 01256 331733 Fax For further information
More informationLatrobe Performing Arts Centre
Latrobe Performing Arts Centre Traralgon Town Hall Technical Specifications Updated 24/5/07 Technical Manager: Phone number: 03 5176 3426 Mobile Number: 0428 378 121 Fax number: 03 5176 3426 Email address:
More informationThe Georgian Theatre Royal Technical Information For Visiting Companies
TECHNICAL EQUIPMENT SCHEDULE 2013 Edition (All equipment is subject to availability) ***ATTENTION VISITING MANAGER/PROMOTER*** Please ensure that the relevant pages of this document (or copies of) are
More informationJERWOOD VANBRUGH THEATRE
JERWOOD VANBRUGH THEATRE HIRES INFORMATION PACK 2013 Contact: +44 (0)20 7908 4822 bookings@radaenterprises.org GENERAL INFORMATION The most famous and most prestigious centre for drama training in the
More informationINFORMATION FOR VISITING COMPANIES
INFORMATION FOR VISITING COMPANIES 2 Middlesbrough Theatre The Avenue Linthorpe Middlesbrough TS5 6SA ADMINISTERED BY MIDDLESBROUGH COUNCIL CULTURAL SERVICES Touring Drama, Dance, Music and Opera, Amateur
More informationTechnical Information
Technical Information For more information please call Booking Agent and Manager: James Marsh 781-586-6770 General Information www.lynnauditorium.com The Lynn Memorial Auditorium is located in historic
More informationCHELSEA THEATRE. Technical Specifications
CHELSEA THEATRE Technical Specifications DIMENSIONS Stage depth From setting line to back wall From front of seats to back wall Width of stage Grid height 6600mm 7200mm 9600mm 3800mm Auditorium Capacity
More informationTechnical Specification Pavilion Dance
Technical Specification Pavilion Dance Contact Information Position Name Email Phone Number Technical Manager Technician Neil Kingston Louise Buckton neil@pdsw.org.uk louiseb@pdsw.org.uk 01202 203630 01202
More informationMain House Technical Specification
Main House Technical Specification Technical Stage Manager: Assistant Technical Stage Manager: Nearest train station: Christchurch Population: 47,300 Distance to London: 105 miles Shaun Luckly Tel: 01202
More informationMatt Dann Cultural Centre
Matt Dann Cultural Centre Matt Dann Theatre Technical Specifications 13/07/09 Technical Manager: Brad Holder Phone number: 08 9158 9369 Mobile Number: 0447 632 936 Fax number: 08 9172 2472 Email address:
More informationThere are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.
Technical Specification Adrian Sweeney Technical and Buildings Manager Office: 01483 739063 Stage Door: 01483 739040 Email: asweeney@glive.co.uk Web: GLive.co.uk 1. Auditorium Capacity Fully seated with
More informationTech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)
Tech specs: Main Auditorium 900 (650 seated on ground floor, 250 on balcony) 1050 (800 standing on ground floor, 250 on balcony) Dimensions Pros Arch 20m x 5.6m high Pros Width 20m (Adjustable via tabs)
More informationThe Tower Theatre Contact - Peter Heselden Theatre Manager Tel
The Tower Theatre Contact - Peter Heselden Theatre Manager Tel- 07711710925 Email- pjwh15@msn.com The Tower Theatre has a seated capacity of 285 in the auditorium with 6 wheel chair positions. The box
More informationDr JOHN GALLAGHER CONCERT CHAMBER
1 TECHNICAL SPECIFICATIONS Dr JOHN GALLAGHER CONCERT CHAMBER STAGE DIMENSIONS 12.5m wide at the downstage edge tapering to 10.7m wide at the far upstage wall. 8m in depth Elevated 0.9m from main auditorium
More informationTechnical Specifications Nov 2016
Technical Specifications Nov 2016 November 2016 1 Cambridge City Centre is a bicycle friendly city. There is short stay car parking in the area of the city, but all of it is expensive for a day stay. The
More informationCENTRE FOR PERFORMING ARTS
CENTRE FOR PERFORMING ARTS Venue, Facilities & Equipment CPA VENUE AREA SIZE FUNCTION Dressing Room (Female) 6 x 12m Dress and makeup room with attached toilet and shower facilities Dressing Room (Male)
More informationDarlington Hippodrome Technical Specification
Darlington Hippodrome Technical Specification 1. Introduction 2. H&S 3. Contact Us 4. Stage 5. Flying 6. Drapes, Masking 7. Stage Management 8. LX control, dimmers, Stock, Aux power 9. Sound 10. Control
More information20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)
Technical Information Stage: Proscenium arch with apron SL Wall - SR Wall: 14.99m Setting Line - U/S Fly Bar: 7.57m Setting Line (under pros, DS edge when orchestra pit out) Back Wall: 8.17m Proscenium
More informationFOX THEATRE ST. LOUIS
FOX THEATRE PAGE 1 OF 7 FOX THEATRE ST. LOUIS CONTACT INFORMATION THEATRE ADDRESS: STAFF CONTACTS: Fox Theatre 527 N. Grand St. Louis, MO 63103 John Wolf Vice President of Theatre Operations 314-657-5060
More informationBURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008
BURDEKIN THEATRE BURDEKIN THEATRE Technical Specifications Updated 08/02/2008 Technical Manager: David Bourke Phone number: 0747 839 888 Mobile Number: 0417 637190 Fax number: 0747 839 889 Email address:
More informationTechnical Specification
Contact us technical@lutonculture.com General Facilities Seating Capacity 238 on raked seating with centre aisle Stage Dimensions 6.4m deep x 8m wide Height of grid 4.2m Height of stage from the auditorium
More informationO Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway
O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway INCOMPLETE AS OF 09-04-2017 DRAFT PURPOSES ONLY 1 of 13 Contents Contents Pg 2 Address Pg 3 Staff Pg 3 Telephone
More informationISLAND HALL TECHNICAL INFORMATION
ISLAND HALL TECHNICAL INFORMATION Lagan Valley Island, The Island, Lisburn, BT27 4RL Telephone: 028 9250 9250 (Reception) If you have any queries regarding this technical information please contact either:
More informationTechnical Specification for the Alley Theatre, Strabane
Technical Specification for the Alley Theatre, Strabane All technical requests should be made to Andrew Orr, Technical Officer. Contact Details Andrew Orr The Alley Theatre, Railway St, Strabane, BT82
More informationADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION
ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION Stage Stage Dimensions: Theater dimensions: Mainstage - 60 0 wide x 28 9 deep. Proscenium arch - 41 6 wide x 28 0 tall. Load gallery on SR
More informationScheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:
Facility Name: IOWA STATE CENTER GENERAL INFORMATION Facility Name: Mailing Address: Phone Number: E-mail Address: IOWA STATE CENTER Scheman Building Suite 102, 1805 Center Drive, Ames, IA 50011 515-294-3347
More informationScheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:
Facility Name: FISHER THEATER GENERAL INFORMATION Facility Name: Mailing Address: Phone Number: E-mail Address: IOWA STATE CENTER Scheman Building Suite 102, 1805 Center Drive, Ames, IA 50011 515-294-3347
More informationTechnical Specifications
Technical Specifications Technical Manager: Kevin Wilkins kbw@canford.com 01202 847543 Theatre Administrator layardtheatre@canford.com 01202 847529 All equipment is subject to availability. Please check
More informationNEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY
NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY VICTORIA THEATER TECHNICAL SPECIFICATIONS Correct as of 11.08.07 Page 1 of 7 LOAD IN The Victoria Theater stage is directly accessible via loading dock
More informationTechnical Information
Technical Information Gracie Fields Theatre, Oulder Hill Leisure Complex, Hudsons Walk, Rochdale, Lancashire OL11 5EF Administration: Nikki Jackson Theatre Manager T: 07824 374913 E: nikki@graciefieldstheatre.com
More informationETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers
PAVILION THEATRE TECHNICAL INFORMATION LIGHTING Permanent fixed lighting rig on fixed dead hung internally wired bar consisting of a 4 colour wash (Lee filters 106 Primary Red, 119 Dark Blue, 105 Orange
More informationW.L. LYONS BROWN THEATRE TECH PACK. Under the Management of
Under the Management of Theater Location 315 West Broadway Louisville, Kentucky 40202-2105 THEATRE STAFF Vice President of Operations: Chuck Schmidt (502) 566-5113 Facility Rental: Brandy Leitner (502)
More informationWRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information
WRIGHT AUDITORIUM TECHNICAL INFORMATION 1. Contact Information 2. General Information 3. Dimensional Information House Goods House Accessories Dressing Rooms (Description) 4. Lighting Information Lighting
More informationMAIN THEATRE TECHNICAL SPECIFICATION
Alcester Street, Redditch, Worcestershire, B98 8AE MAIN THEATRE TECHNICAL SPECIFICATION Updated 28 th February 2018 Administration 01527 61544 Select department from the options Box Office 01527 65203
More informationHIRE AND TECHNICAL INFORMATION
HIRE AND TECHNICAL INFORMATION 2 Table of Contents Stage Information... 3 Accommodation... 4 Lighting Equipment... 5 Sound Equipment... 7 In-House Cloths... 8 Stage Plan... 9 Contact Information.. 10 Parking
More informationPhil L. Thomas Performing Arts Center Shiprock, New Mexico
Phil L. Thomas Performing Arts Center Shiprock, New Mexico Technical Specifications STAGE DIMENSIONS Proscenium 45-4 wide x 24 high Proscenium to up stage wall 29 6 (from back of proscenium opening wall)
More informationSHUBERT THEATER 247 College Street, New Haven, CT
SHUBERT THEATER 247 College Street, New Haven, CT 06510 203-624-1825 TECHNICAL SPECIFICATIONS and EQUIPMENT INVENTORY HALL SEATING CAPACITY Orchestra 665 Mezzanine 474 Balcony 392 Boxes 60 TOTAL 1591 STAGE
More informationStage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Setting line 200mm upstage from the fire curtain.
Technical specifications STAGE Brief stage description Stage one: With retractable seating out, unraked stage without a proscenium arch or fly tower (10 metre ceiling). Surface hardwood floor covered with
More informationDubbo Regional Theatre & Convention Centre Theatre Technical Specifications
Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications Updated: April 2018 Technical & Production Coordinator: David Brown Phone number: 0268014372 Fax number: 0268014259 Mobile: 0418270500
More informationTechnical Information
5/3/2006 1 Hamilton Place Theatre / Studio at Hamilton Place / Copps Coliseum / Hamilton Place Convention Centre Ronald V. Joyce Centre for the Performing Arts Technical Information Building with members
More information2017 TECHNICAL SPECIFICATIONS
2017 TECHNICAL SPECIFICATIONS Venue Address: Shirley Burke Theatre 64 Parkers Road, Parkdale Victoria 3195 SBT Theatre Coordinator: Tracey Kean Phone number: 9580-4998 Mobile number: 0400-657-987 tracey.kean@kingston.vic.gov.au
More informationTechnical Specifications. Taylor Little Theater
501 East 38 th Street Erie, PA 16546 Technical Specifications Taylor Little Theater in Weber Hall Revised: March 12, 2013 SEATING CAPACITY 250 SEATS Handicap and wheelchair accessible TELEPHONE NUMBERS
More informationTheatre Technical Specification
Theatre Technical Specification The information contained in this specification details the standard technical provision offered by the Brewhouse for visiting companies, artists and hirers. It details
More informationPleasance London Main House Visiting Company Information Pack May 2017
Pleasance London Main House Visiting Company Information Pack May 2017 Contact List Director Anthony Alderson anthony@pleasance.co.uk General Manager Hamish Morrow hamish@pleasance.co.uk Head of Comedy
More informationStage. Get In & Parking
Stage Capacity Stage Rigging Masking Auditorium 230 seats or 216 seats if front row removed. Wheelchair positions front row and upper auditorium right. Raked seating upper & lower house. 9.45m wide x 6.9m
More informationLighthouse Theatre Technical Specification
Lighthouse Theatre Technical Specification Auditorium Ground Floor 15.3m x 17.5m Balcony 4.5m x 17.5m Capacity 548 Seating Disabled Seating General Fixed tiered seating; 405 ground floor, 119 balcony,
More informationMAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014
Alcester Street, Redditch, Worcestershire, B98 8AE MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014 Administration 01527 61544 Select department from the options Box Office 01527 65203 For
More informationHopgood Theatre NOARLUNGA CENTRE
Hopgood Theatre NOARLUNGA CENTRE TECHNICAL FACILITIES Technical Manager: Paul Smith 0402 574 694 (M) paul.smith@countryarts.org.au Ramsay Place, PO Box 747 Noarlunga Centre, SA 5168 Box Office: (08) 8207
More informationTECHNICAL PACKAGE.
TECHNICAL PACKAGE Music Hall Center for the Performing Arts Main Stage: Stage Dimensions: Drapery: Grid Pipes: Electrical: Units: Power: Piano: Main Auditorium: Technical Specifications - abbreviated Wall
More informationTechnical Specification. Updated: April 2016
Technical Specification Updated: April 2016 Venue Address: The Core at Corby Cube Parkland Gateway George Street Corby Northants NN17 1QG Contact: Andy Swinney Technical Manager Tel: 01536 470475 Email:
More informationTechnical Specifications
FOLLY THEATER 300 W. 12th Street Kansas City, Missouri 64105 Stephanie Spatz-Ornburn, Event Manager Business Office: (816) 842-5500 FAX: (816) 842-8709 Email: Stephanie@follytheater.org Lee Saylor, Technical
More informationTechnical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3
Sound Console: Soundcraft Si Performer 3 32 mono mic inputs 80 channels to mix Freely assignable faders and patching Colour backlit LCD screens per fader 20 sub-group / aux busses 8 Matrix busses LCR panning
More informationTechnical requirements & conditions for hirers
Technical requirements & conditions for hirers This form is designed as the basis for a pre-production meeting between the Stage Manager/Hirer and the Mechanics Technical Manager at which production details
More informationMERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.
MERMAID ARTS CENTRE Outline Technical Specifications as of 17 th January 2018. At Mermaid we are regularly upgrading our inventory. Please ensure you have a current version of this document. Note: Please
More informationRPAC REDLANDS PERFORMING ARTS CENTRE
RPAC REDLANDS PERFORMING ARTS CENTRE CONCERT HALL Technical Specifications STAGE FACILITIES Soft Proscenium Theatre mode (see stage masking) Concert Platform (open area with acoustic walls on PS, OP and
More informationStage point load limit: Stage point load of 700kg. Stage dimensions Non-proscenium stage. Access door to stage from scene dock - 2.9m by 2.9m.
Technical specifications STAGE Brief stage description Stage one: The Cube is a flat floor, multipurpose space with a retractable seating bank and balcony seating. There is no proscenium arch or fly tower
More informationTechnical Specifications Updated 01/10/2017. Stage
Stage Capacity Setting Line Stage Please see your contract for capacity. Setting line(s) is 1.35m from the step of row A of the seating bank or 1.35 from the onstage edge of seats. All fire paths should
More informationMONASH University Academy of Performing Arts
MONASH University Academy of Performing Arts ROBERT BLACKWOOD HALL Technical Specifications Matthew King Technical Manger Phone number: (03) 9905 1689 Email address: matthew.king@monash.edu Updated December
More informationAmarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101
AUDITORIUM Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101 The Amarillo Civic Center Auditorium is a proscenium theatre with no balcony. The theatre seats 2,310 with an additional
More informationT1 National Theater. Auditorium (Basement 1): 324 Under Balcony (Ground floor): 388 Royal Circle (Level 1): 161 Level 2: 316 Level 3: 422
T1 National Theater Total Seating Capacity: 1714 + 10 wheelchair spaces Total Orchestra Pit seats: 93 Orchestra Pit Section 1: 44 Orchestra Pit Section 2: 49 Auditorium (Basement 1): 324 Under Balcony
More information1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax
1400 MARKET STREET ST LOUIS, MISSOURI 63103 314-499-7600 Main Number 314-499-7601 Main Fax www.peabodyoperahouse.com MATTHEW DEWEY GENERAL MANAGER Tel: 314-499-7700 Cell: 913-209-5148 Email: mdewey@peabodyoperahouse.com
More informationTECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013
TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA 01420 UPDATED March 2013 Cultural Affairs Office: 978-665-3709 Web Site: www.fitchburgstate.edu/cultural
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS September 2017 TECHNICAL CONTACTS Technical Manager Clive Stevenson 01865 319451 stevensonc@thenorthwall.com Stage Manager Rebecca Welburn 01865 319451 welburnr@thenorthwall.com
More informationTechnical Specifications
FOLLY THEATER 300 W. 12th Street Kansas City, Missouri 64105 Technical Specifications Stephanie Spatz-Ornburn, Event Manager Lee Saylor, Technical Director Business Office: (816) 842-5500 Production Office:
More informationTechnical Services and Specification
Technical Services and Specification BRAUNTEX PERFORMING ARTS THEATRE ASSOCIATION, INC. 290 West San Antonio New Braunfels, TX 78130 (830) 627-0808 FAX (830) 627-0809 Operations Manager: Ben Nowotny -
More informationTechnical Specifications
Technical Rob Adams Technical Operations Director 321-433-5822 321-433-5817 fax adamsro@easternflorida.edu rev. 01.MARCH.2017 King Center House Technical Maxwell C. King Center for the Performing Arts
More informationParamount Theatre Production Recap
Paramount Theatre Production Recap Built in 1928 as a motion picture palace and vaudeville playhouse, the 3,000 seat theatre was billed as the largest and most beautiful theatre west of Chicago. Paramount
More informationTechnical Specification Ardhowen Theatre
Technical Specification Ardhowen Theatre Stage Proscenium Width Depth Forestage Height Stage Floor Flying System Stage Manager Orchestra Pit House Curtains Masking Cyclorama 8.6M (28.2ft) wide by 5.3M
More informationStandard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)
AUDITORIUM PERFORMANCE AREA Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black) Standard (with THRUST seating) 6.1m Wide
More informationEsso BHP Billiton Wellington Entertainment Centre
Esso BHP Billiton Wellington Entertainment Centre John Leslie Theatre Technical Specifications Updated July 2008 Technical Manager: Brendan Peters Phone number: 03 5143 2511 Mobile Number: 0417 166 159
More informationTECHNICAL SPECIFICATIONS: STICKS STONES BROKEN BONES Company: Bunk Puppets, contact :Jeff Achtem,
TECHNICAL SPECIFICATIONS: STICKS STONES BROKEN BONES Company: Bunk Puppets, contact :Jeff Achtem, jachtem@yahoo.com General Specifications Sticks Stones, Broken Bones is a flexible show adaptable for large
More informationTHE STREET THEATRE. Technical Specifications
THE STREET THEATRE Technical Specifications Updated 02/03/10 Technical Coordinator: Gillian Schwab Phone number: 02 62471519 Fax number: 02 6247 3808 Email address: gillians@thestreet.org.au Program Manager:
More informationThe Standard Bank Studio is a music venue made from the choir stalls and the stage of the Cape Town City Hall Auditorium. It
Standard Bank Studio Technical Specification STAGING Stage Depth: 5.5m Stage Width: 9.8m Height: Stage Elevation: 5m (from stage floor to truss) 0m Seating Capacity: 180 Loading Door: Double Door fire
More informationShouson Theatre Venue Specifications (updated Jan 2017)
Shouson Theatre Venue Specifications (updated Jan 2017) Shouson Theatre is the largest venue in HKAC with capacity 439 seats. The proscenium theatre offers superb views from every seat, which audiences
More informationPerforming Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)
1 Seating Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI 49544 Phone: (616) 647-0939 Fax: (616) 647-0149 Technical Specifications As of June 2009 Total Seating Capacity 756 + 4 wheelchair spaces
More information* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.
Technical Information Centerville Performing Arts Center Centerville High School 500 E. Franklin Street, Centerville, OH 45459 Theatre Manager: Mike Cordonnier Office: 937-439-3535, Fax: 937-439-3574 E-Mail:
More informationTECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS MAIN HOUSE TECHNICAL SPECIFICATION LIGHTING ETC ION lighting desk with 2x 20 fader bank (NB this is an XP ION) 126 ways of dimming supplied by LSC digital dimmer packs. All outlets
More informationTechnical Specification
Braintree Arts Theatre Notley Road Braintree Essex CM7 1WY t: 01376 556354 e: enquiries@braintreeartstheatre.com Technical Specification Theatre and Technical Manager: Phil Pattie phil.pattie@braintreeartstheatre.com
More informationThe Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW
The Haymarket Technical Specifications The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW Head of Production E: ruairi.mcnulty@anvilarts.org.uk T: 01256 819797 Ext: 118 Production and E: amanda.wise@anvilarts.org.uk
More informationJohn Leslie Theatre. Technical Specifications. Updated July 2018
John Leslie Theatre Technical Specifications Updated July 2018 Generated from the APACA Technical Specifications Template. For more details visit www.apaca.com.au Coordinator Operations: Brendan Peters
More informationARTPARK MAINSTAGE THEATER TECHNICAL PACKET
ARTPARK MAINSTAGE THEATER TECHNICAL PACKET LOCATION: 450 South 4 th Street, Lewiston, NY 14092 CONTACT: Sonia Kozlova Clark, Executive Director: sclark@artpark.net 716-754-9000 x 117 Susan Stimson, Production
More informationTechnical Rider. STAGE 32 m wide x 13 m deep (from the prompt)
Technical Rider STAGE Main stage Proscenium opening Front stage Back stage Grid Floor Ballet floor Stage height 32 m wide x 13 m deep (from the prompt) max. 18 m - min. 12 m - max. 9 m high 3,5 m (from
More informationStudio Theatre. Technical Specifications. Theatre Manager Kim Scarlata Box Office Coordinator Laura Johnston
Studio Theatre Technical Specifications Theatre Manager Kim Scarlata 209.831.6205 Box Office Coordinator Laura Johnston 209.831.6208 Theatre Operations & Technical Assistant Matthew Morgan 209.831.6275
More informationTECHNICAL SPECIFICATIONS RIVERSIDE THEATRE
TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE - 2014 Standard Lighting Rig is a four (4) colour wash onstage and five (5) colour wash Front of House Standard Flying Rig is attached to this document and is
More information"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements
Although we aim to present our work with simple staging, we also require very high technical standards. If you are unable to meet any of the requirements given here please contact us as soon as possible,
More informationStage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking
Stage Capacity Auditorium 230 seats (216 seats when front row is removed). Wheelchair positions front row and upper auditorium right. Raked seating split onto lower & upper house. Stage Width - 9.1m Depth
More informationDUNSTAN PLAYHOUSE TECHNICAL SPECIFICATIONS
DUNSTAN PLAYHOUSE TECHNICAL SPECIFICATIONS Adelaide Festival Centre Trust Street Address: King William Road, Adelaide Postal Address: GPO Box 1269 Adelaide, SA, 5001 AFCT Reception - Phone: (08) 8216 8600,Fax:
More informationTechnical Specification
Technical Specification Address: The Mill Arts Centre Spiceball Park Road Banbury OX16 5QE Website: www.themillartscentre.co.uk Telephone: Box Office: (01295) 279002 Head of Technical and Production: Dan
More informationTechnical Director of Production Andrew Quick Ext 252
Technical Specification NST City April 2018 General Information Address NST City 144 Above Bar St Southampton SO14 7DU Contact Information Administration: 023 8031 5500 Box Office: 023 8067 1771 info@nstheatres.co.uk
More informationUNIVERSITY CONCERT HALL. Technical Specification
UNIVERSITY CONCERT HALL Technical Specification Auditorium Total Seating 1,039 Seating breakdown Ground Floor 795 Balconies 191 Choir Stall 53 Wheelchair lift to four disabled positions Stage Performing
More informationCross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way
Theatre Specifications Toombs Auditorium Address: 3001 East First St. Vidalia GA 30474 Julie Busby, Auditorium Manager Phone: 912-538-3135 Fax: 912-538-3164 E-mail: jbusby@southeasterntech.edu Seating
More informationGORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16
WWW.GORDON-CRAIG.CO.UK BOX OFFICE 01438 363 200 GORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16 STAFF CHIEF TECHNICIAN (SOUND) Dave Nott Email: dave.nott@sll.co.uk Tel: 01438 242612 Mob:
More informationThe Mannie Manim Technical Specifications
The Mannie Manim Technical Specifications 1 TECHNICAL CONTACTS Hailey Kingston Production Manager +27 72 236 5978 haileyk@markettheatre.co.za Thapelo Mokgosi Production Manager/Lighting Designer +27 82
More informationTHEATRE ROYAL MARGATE Technical Specification January 2016
THEATRE ROYAL MARGATE Technical Specification January 2016 ATTENTION VISITING MANAGER/PROMOTER Please ensure that the relevant pages of this document (or copies of) are sent to your production staff, at
More informationTHE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015
THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015 CONTACTS Matt Schliesman, Executive Director 913 South 8 th Street Email: matts@cccshows.org Peggy A.
More informationTechnical Specifications
Information and scheduling for the following services and equipment are coordinated through the Stafford Centre s Technical Production Department. Technical and/or production requirements Facility information
More information