Quick Reference Manual

Size: px
Start display at page:

Download "Quick Reference Manual"

Transcription

1 Quick Reference Manual V1.0 1

2 Contents 1.0 PRODUCT INTRODUCTION SYSTEM REQUIREMENTS INSTALLING PDF-D FLEXRAY PROTOCOL ANALYSIS SOFTWARE CONNECTING TO AN OSCILLOSCOPE CONFIGURE THE PDF-D SOFTWARE SIGNAL INPUTS SIGNAL CONFIGURATION DATA REFERENCE DISPLAY OPTION RESULTS DECODE TABLE INFORMATION LINKING DECODED FLEXRAY FRAME DATA TO WAVEFORM SHOW MORE DETAIL Overlay of decoded messages on the FlexRay waveform Eye Diagram Analysis Time Interval Error Plot (TIE Plot) Timing Measurements Sync Measurements FIND SAVE CLOSE THE DETAIL VIEW CLOSING THE PDF-D FLEXRAY DECODE ANALYSIS SOFTWARE FEEDBACK CONTACT INFORMATION

3 1.0 Product Introduction Engineers designing and integrating in-vehicle networks can monitor FlexRay protocol information in hexadecimal and decimal formats, analyze the electrical characteristics of a FlexRay signal using eye diagrams, time interval error plots and sync measurements with a Tektronix DPO/MSO4000 Series oscilloscope and the FlexRay Protocol Analysis Software The PDF-D FlexRay Protocol Analysis Software offers the best solution in the industry for debugging and testing of FlexRay signals using the award winning Tektronix DPO4000 and MSO4000 Series oscilloscopes. This software enables the designer to capture thousands of FlexRay messages and display the decoded data. The PDF-D FlexRay decode feature allows the users to view the decoded data in hexadecimal, decimal, octal and binary formats as specified. PDF-D Software overlays control and payload data of the FlexRay frame on the waveform for easy debugging FlexRay communication l issues. The protocol decode table highlights the header CRC, trailer CRC and eye diagram error frames (frames causing eye diagram failure) in red. 3

4 Signal Integrity Electronic control units (ECU s) should work in extreme operating conditions in an automobile. To ensure reliable operation of ECU s at extreme operating conditions, FlexRay signal should have enough design margins. PDF-D Software s signal integrity feature helps in quickly analyzing the electrical characteristics of FlexRay signal. Advanced features such as eye diagram analysis, time interval error plot, and sync measurements enables the user to know the eye opening, jitter, and synchronization in a FlexRay network. Features: Protocol decode Converts time domain waveform information into data domain and displays the contents in FlexRay message format Displays waveform and decoded data simultaneously in a single window allowing efficient debugging Ability to link any FlexRay frame or any message (data or address) to waveform allows efficient analysis of FlexRay communication Detailed view plots the waveform for the selected frame and overlays the decoded data on the waveform. Error frames are highlighted in red for easy debugging. Find function helps in quickly locating the specific data or address out of thousands of decoded FlexRay messages Time stamp with reference to trigger position allows users to know the time from the frame to the trigger event Offline analysis with Ref waveforms,.isf (Tektronix oscilloscope s internal waveform file format) and,.csv files Capability to save the decoded messages in.csv format Features: Signal Integrity Ability to view the eye diagram for selected message with the complete acquired data helps in pinpointing the cause for the eye diagram failure Quick analysis of the eye diagram as per FlexRay standard FlexRay frames causing eye diagram errors are highlighted in red in the decode table Time interval error analysis for each frames helps in understanding the influence of oscillator stability in each FlexRay node Sync measurements enable the user to know time lapse between the sync frames Average bit time measurement 4

5 2.0 System Requirements The following are the system requirements to install and use PDF-D FlexRay software OS RAM Disk Space Display Resolution Windows 2000 SP4, Windows XP SP2, Windows Vista 512 MB or more 10 MB or more 1,024x768 minimum 3.0 Installing PDF-D FlexRay Protocol Analysis Software The software requirements to install PDF-D Software on your PC are: TekVISA 3.3 or above version.net 2.0 Framework SP2 Follow the below steps to install the PDF-D Software. If your PC already has TekVISA and Dotnet framework software, you can skip step # 3 and Insert the PDF-D Software CD in the CD Drive of your PC. 2. Open the CD drive using My Computer or explorer. You will find the following files in the PDF-D Software CD dotnetfx.exe TekVISA. exe FlexRay Protocol Analysis Software VX.X.X.exe 3. To load dotnetfx.exe software, double click on dotnetfx.exe file. It will take you through the installation procedure of.net Framework software. 4. To load TekVISA software, double click on TekVISA.XXX.exe. Software will take you through the installation procedure. 5. To load PDF-D Software, double click on FlexRay Protocol Analysis Software V1.x.x.exe. Software will take you through the installation procedure. 6. At the end of the PDF-D Software installation, following icon is created in your PC desktop. FlexRay Protocol Analysis Solution.lnk 7. To launch the PDF-D Software, double click on the above shown icon. 5

6 4.0 Connecting to an Oscilloscope The PDF-D FlexRay Analysis Solution connects to an oscilloscope using TekVISA. To establish the connection between the oscilloscope and the application, you need to setup the oscilloscope and the PC. Configure the oscilloscope for USB connectivity TekVISA lets you use your MS-Windows computer to acquire data from your oscilloscope for use in an analysis package that runs on your PC, such as the PDF-D FlexRay Protocol Analysis software. You can use a common communications connection, such as USB, Ethernet, or GPIB, to connect the computer to the oscilloscope. To set up TekVISA communications between your oscilloscope and computer: 1. Load the VISA drivers on your computer. The TekVISA driver is provided with the CD you received with this software or with your oscilloscope. If you do not have a CD, you can download it from the Tektronix Web page ( 2. Connect the oscilloscope to your computer with the appropriate USB or Ethernet cable. 6

7 3. Press the Utility button on the oscilloscope front panel as shown below. 4. Press the Utility page in the oscilloscope menu. 5. Turn the multipurpose knob a on the oscilloscope and select I/O. 6. If you are using USB, the oscilloscope sets itself up automatically for you, if USB is enabled. Check USB on the lower-bezel menu to be sure that USB is enabled. If it is not enabled, press USB. Then press Enabled on the side-bezel menu. 7. To use Ethernet, press Ethernet Network Settings. If you are on a DHCP Ethernet network and are using a regular Ethernet cable to connect, on the side-bezel menu, set DHCP to On. If you are using a cross-over cable, set it to Off and set a hard coded TCP/IP address. After configuring the oscilloscope you need to configure TekVISA on your computer. 7

8 Configure TekVISA on your computer PDF-D FlexRay Analysis solution connects to the oscilloscope using TekVISA. To establish the connection between the oscilloscope and the application, you need to configure TekVISA on your computer. Steps to configure TekVISA: 1. Open the TekVISA Instrument Manager from Start Menu> All Programs >TekVISA> OpenChoice Instrument Manager as shown; 2. Click the Search Criteria button to configure the type of connection. 8

9 3. If you are using Ethernet, configure the network address as shown below and click Done. 4. Click Update in the Instrument Manager. You will then find your oscilloscope in the list of instruments. 9

10 5. To get an easier to recognize VISA name, select the instrument and click Properties. The following dialog box will appear. Provide a Device Name, for example DPO4000 and then click OK. 6. Click Update in the instrument list. You will find the newly created Device Name in the list of Instruments. 10

11 5.0 Configure the PDF-D Software Launch the FlexRay app by clicking FlexRay Protocol Analysis Solution icon on your PC desktop, The following screen appears when the application launches. Provide the new device name in the PDF-D FlexRay VISA Name and click Connect to Oscilloscope as shown. This interface allows you to set up the PDF-D application for FlexRay signal analysis. The three important components in configuration tab. Signal Inputs Signal Configuration Data Reference 5.1 Signal Inputs PDF-D allows you to input a FlexRay signal using CH1-CH4, Ref1-Ref4 or the Math channel on a DPO/MSO4000 Series oscilloscope. Using the drop down list you can select any of the channels. A FlexRay signal is a differential signal. You can probe the differential signal using a TDP0500 differential probe or with two single ended probes and a Ch1-Ch2 math function. This pseudo differential approach requires you to select the scope s Math waveform as the input. If you plan to probe the FlexRay signal using a TDP0500 probe: Connect the TDP0500 to any of CH1 to CH4 of DPO/MSO4000 Series oscilloscopes. Select CH1-CH4 in PDF-D depending upon the TDP0500 connectivity. For example, if TDP0500 is connected to CH1 in DPO/MSO4000 then select CH1 in PDF-D. 11

12 If you plan to probe the FlexRay signal using a pseudo differential method: Connect CH1 and CH2 of DPO/MSO4000 to BP and BM of FlexRay signal respectively. You can use the standard P6139A probes supplied with the oscilloscope. To get the differential FlexRay signal, set up the Math channel in DPO/MSO4000 Series oscilloscope as Math1 = CH1-CH2. Select Math in PDF-D depending upon the math channel configuration. If you want to analyze the single-ended FlexRay signals, use the following setup: Note: While conducting single-ended signal analysis, the eye-diagram feature is irrelevant, because the eye diagram analysis requires differential signal. Connect the BP or BM signals to any of CH1-CH4 of DPO/MSO4000 Series oscilloscope using P6139A probe. Select CH1-CH4 in the PDF-D software. If you want to analyze previously saved FlexRay waveforms: Load the FlexRay signals (.isf files) into any of the Reference channels of DPO/MSO4000 Series oscilloscope. Select Ref 1-Ref4 in the PDF-D Software. If you want to analyze FlexRay signals from a file: Load the FlexRay signal files using the file menu of PDF-D. PDF-D supports.isf and.csv files. 12

13 5.2 Signal Configuration Signal configuration enables you to input the characteristics of your FlexRay signal and test point information to the PDF-D Software. The signal configuration panel of PDF-D is as shown: Signal Type: This menu is used to select whether BP, BM or differential signal is used for analysis. Data rate: FlexRay supports 3 different data rates 10Mbps, 5Mbps and 2.5Mbps. Select the appropriate data rate using the drop-down list. Channel: FlexRay supports two channels for data exchange between FlexRay nodes. Many times one of the channels is used as for redundancy. Based on this selection the software computes the trailer CRC value and flags an error message if any difference is detected. You can select channel A or Channel B using the drop-down list. Eye Mask: This drop-down list enables you to select the Eye mask at test points TP1 or TP4. The FlexRay standard recommends eye diagram testing at test points TP1 and TP4. 13

14 5.3 Data Reference To analyze the FlexRay signals, PDF-D needs to identify the logical high and low transitions. For this, you need to provide the reference level as input. The reference level inputs can be specified as percentage or absolute units. The screen is as shown below. In the percentage mode, the PDF-D software measures the maximum and minimum amplitude of the FlexRay signal. If the Ref level is set as 50%, then any transition above 50% of amplitude is considered as logical 1 and below 50% of amplitude as logical 0.. 5% Ref Level (from 50% ref level) 50% Ref Level 5% Ref Level (from 50% ref level) Hysteresis level setup helps in isolating incorrect voltage transition occurring due to the electrical noise. 14

15 Any aberration (as shown in the above figure) within 50%+/-5% of 50% reference level is not considered a logical transition. The hysteresis level helps in isolating voltage transitions in the hysteresis region. If units are set to absolute, you can set the Reference level in volts. If the signal voltage amplitude is 5V then you can set Ref level at 2.5V. Hysteresis level can be 0.5V. Hide eye diagram error: By selecting this check box, PDF-D will not highlight the FlexRay frames causing an eye diagram error. 5.4 Display Option This menu allows you to configure the view of decoded FlexRay frame contents in different numerical formats. You can configure Frame ID, payload length, header CRC, cycle count, data and data annotation in hexadecimal, decimal, binary or octal numerical formats. To access display options, select Option in the menu bar. The following display appears. Use the drop-down list to select decimal, hexadecimal, octal or binary formats. This information is used to display the protocol decoded information of the FlexRay signal. Acquire Data: By clicking on acquire data, PDF-D software sends commands to the oscilloscope to acquire data using the current oscilloscope setup. The data is then imported into the PDF-D software, and the results are displayed. 15

16 6.0 Results The results tab displays the results after processing the acquired data. The results tab contains: Decode Table Show More Details Find Save 6.1 Decode table information The Decoded FlexRay frame contains the following information: Header Frame Type (FT) Reserved Bit (RB) Payload Preamble (PP) Null Frame Indicator (NI) Sync Frame Indicator (Sy) Start up Frame Indicator (St) Frame ID (F ID) Payload Length (PL) Header CRC (H CRC) Cycle Count (CC) Time Data Description Static Frame (S) or Dynamic Frame (D) Value of the Reserved Bit Payload Preamble in the Frame Header Displays the status of the Null Frame Indicator in the Frame Header Displays the status of the Sync Frame Indicator in the Frame Header Displays the status of the Start up Frame Indicator in the Frame Header Displays the Frame ID Displays the Payload Length of the Frame Displays the Decoded Header CRC value Displays the Decoded Cycle Count Displays the Start of the frame time from the Trigger Position Displays the Payload Data 16

17 The next figure explains the FlexRay frame content in a standard FlexRay frame. PDF-D displays the results as shown: Note that if the decoded data is displayed in hexadecimal, binary and octal formats then h, b, and o is appended to the data bytes. If it is in decimal format then there is no indication for the data bytes. 6.2 Linking decoded FlexRay frame data to waveform After the PDF-D completes the decoding, by default it zooms and places the cursors in the oscilloscope waveform. This waveform represents the first decoded frame in the decode table. You can scroll up and down the decoded table display. If you want to view the waveform for a particular FlexRay frames in decoded table, click on the frame. The waveform related to this frame is zoomed and cursors are placed at the start and end of 17

18 the frame in DPO/MSO4000. The DPO/MSO4000 oscilloscope display is as shown while linking the decoded frame to waveform. 6.3 Show more detail By selecting the Show More Details in the results panel, you can view the comprehensive analysis of the FlexRay frame. The following features are supported in detailed view. Overlay of decoded message on the FlexRay waveform Eye diagram analysis TIE plot Timing measurements Sync Measurements 18

19 A typical display of Show More Detail view along with the decoded table is as shown: Overlay of decoded messages on the FlexRay waveform One of the components in detail view is the overlay of decoded messages on the FlexRay frame waveform. The component is displayed as shown: Fit to screen Pan/Zoom Undo The decoded information of the frame selected in the decode table is overlaid with the corresponding FlexRay waveform. To zoom this waveform: Step 1: Click on the pan/zoom button in waveform plot. Step 2: Move the mouse pointer over the waveform plot. Step 3: Click and drag to select the area to zoom on 19

20 To pan the zoomed waveform: Step 1: Click on the pan button. Step 2: Move the mouse pointer over the waveform plot. Step 3: Click and drag either left or right to pan left or right respectively To do undo the last action, click the undo button Eye Diagram Analysis The Eye diagram plot component in detail view is as shown. Maximize The eye diagram is built from all the FlexRay frames acquired in a single acquisition on the DPO/MSO4000 Series oscilloscope. The blue trace in the eye diagram is the eye for the selected frame in the decode table. To maximize the eye diagram plot area, click the maximize button eye diagram plot area, click.. To minimize the Eye diagram failures are highlighted in red as shown in the following figure. 20

21 The FlexRay frames causing these eye diagram failures are as also highlighted in red in the decode table as shown below. 21

22 6.3.3 Time Interval Error Plot (TIE Plot) This component of the Detail view offers the TIE plot for the selected frame. The plot is displayed as shown.. A TIE plot shows the time difference between the real clock and an ideal clock (standard specification) for each Unit Interval (UI) for the FlexRay frame selected in the decode table. The X axis of the TIE plot is UI and the Y axis is time in seconds. If the data rate is 10 Mbps, the UI is 100nsec (ideal clock). If the measured UI for each UI were 100nsec, then the plot would be a flat line at 0 seconds. If it varies against the reference UI value of 100nsec (for 10 Mbps), the difference value (measured UI value reference UI value) is plotted for each UI in the time axis. A UI increment starts from the beginning of the FlexRay frame. Using the TIE plot you can quickly observe the UI time variation in a selected frame. This UI variation might have occurred while data is being transmitted through the different segments of the network. Also, the impact of oscillator frequency variation in an ECU can be observed in a TIE plot. Electrical noise can impact the UI value which can be easily observed by a sudden change in UI value in a TIE plot Timing Measurements This component of the Detail view shows timing measurements for the selected frame. The measurements are displayed as shown. 22

23 The rise time is the amount of time the output voltage takes to reach from 20% to 80% of the amplitude. The fall time is the time the output voltage takes to reach from 80% to 20% of the amplitude. In PDF-D software rise and fall time are calculated for all the transitions in the frame and the average value is displayed. TSS duration is a programmable value in FlexRay nodes. The measured TSS value helps in identifying any TSS truncation issues due to signal paths in the network Sync Measurements This component in Detail view gives the following measurements. Previous Sync and Next Sync measurements measure the time lapsed and time at which next sync frame is expected for the selected frame. Previous Cycle Frame and Next Cycle Frame measurements measure the time lapsed for the same frame in previous communication cycle and time at which this frame is present in the next communication cycle. 23

24 6.4 Find Clicking on the Find button brings up the following dialog box You can find Frame Indicators, Frame Details, Frame Type and Error frames in the decode table. To search, do the following: Step 1: Select your search criteria in the Find menu Step 2: Enter the search value (if you are searching for Frame details) Step 3: Click on Find; PDF-D will search for frames meeting your criteria in the decode table. Step 3: If condition is present, that row is selected Step 4: To continue searching in rest of the decode table, click on Find until PDF-D displays following message. 24

25 You can also search for a combination of Find conditions. For example, search for Frame ID=14 and Data of Dh by setting the search conditions as shown below: You can also search for a combination of Frame details and Errors. For example to find frames with an ID of 24 that fail the eye diagram test, set the search conditions as follows: 25

26 6.5 Save The save feature allows you to save the decode table information in.csv file format. To save the data, click on the Save button. The following dialog appears: 6.6 Close the Detail View To close the Detail View, click on the close button at right corner of the Detail view display Or uncheck the Show More Details checkbox in the results panel Closing the PDF-D FlexRay Decode Analysis Software To close the PDF-D FlexRay Decode Software, click on the close button at the right corner of the PDF-D Software user interface or by selecting Exit in the File menu. 26

27 8.0 Feedback Prodigy Test Solutions values your feedback on our products. To help us serve you better, please send us your suggestions, ideas, or comments on your application. Direct your feedback via to and include the following information. Please be as specific as possible. General information: Oscilloscope model number and hardware options, if any probes used. Your name, company, mailing address, phone number, FAX number. Please indicate if you would like to be contacted by Prodigy Test Solutions about your suggestions or comments. Solution specific information: PDF-D software version number. Firmware version of the oscilloscope. Description of the problem such that technical support can duplicate the problem. If possible, save the oscilloscope setup files as a.set file. If possible, save the waveform on which you are performing the measurement as a.isf file. Once you have gathered this information, you can contact technical support by phone or through . If using , be sure to enter in the subject line PDF- D FlexRay Problem or PDF-D FlexRay Feedback and attach the.set and.isf files. 9.0 Contact Information Prodigy Test Solutions #15/130, 3 rd Floor, 1 st Cross, 8 th Main, BTM 1st Stage Bangalore Karnataka, India contact@prodigytest.com Phone numbers: /

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes Data sheet This application is available in the following license variations. Order N8803B for a

More information

FLEXRAY TRIGGER, DECODE, AND PHYSICAL LAYER TEST

FLEXRAY TRIGGER, DECODE, AND PHYSICAL LAYER TEST FLEXRAY TRIGGER, DECODE, AND PHYSICAL LAYER TEST Operator s Manual MARCH, 2008 LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY 10977 6499 Tel: (845) 578 6020, Fax: (845) 578-5985 Internet:

More information

5 Series MSO Serial Triggering and Analysis Applications 5-SRAUDIO, 5-SRAUTO, 5-SRCOMP, and 5-SREMBD Datasheet Serial triggering

5 Series MSO Serial Triggering and Analysis Applications 5-SRAUDIO, 5-SRAUTO, 5-SRCOMP, and 5-SREMBD Datasheet Serial triggering 5 Series MSO Serial Triggering and Analysis Applications 5-SRAUDIO, 5-SRAUTO, 5-SRCOMP, and 5-SREMBD Datasheet Serial triggering Trigger on packet content such as start of packet, specific addresses, specific

More information

FlexRay Physical Layer Eye-diagram Mask Testing

FlexRay Physical Layer Eye-diagram Mask Testing FlexRay Physical Layer Eye-diagram Mask Testing Application note Introduction Eye-diagram mask testing is one of the most important physical layer measurements that you can use to test the overall signal

More information

TekExpress Ethernet Tx Compliance Solution Printable Application Help

TekExpress Ethernet Tx Compliance Solution Printable Application Help TekExpress Ethernet Tx Compliance Solution Printable Application Help *P077125300* 077-1253-00 TekExpress Ethernet Tx Compliance Solution Printable Application Help www.tek.com 077-1253-00 Copyright Tektronix.

More information

Troubleshooting Your Design with Tektronix MSO and DPO Series Oscilloscopes

Troubleshooting Your Design with Tektronix MSO and DPO Series Oscilloscopes Troubleshooting Your Design with Tektronix MSO and DPO Series Oscilloscopes Our thanks to Tektronix for allowing us to reprint the following article. Today s engineers and technicians face increasingly

More information

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

Reference. TDS7000 Series Digital Phosphor Oscilloscopes Reference TDS7000 Series Digital Phosphor Oscilloscopes 07-070-00 0707000 To Use the Front Panel You can use the dedicated, front-panel knobs and buttons to do the most common operations. Turn INTENSITY

More information

The Measurement Tools and What They Do

The Measurement Tools and What They Do 2 The Measurement Tools The Measurement Tools and What They Do JITTERWIZARD The JitterWizard is a unique capability of the JitterPro package that performs the requisite scope setup chores while simplifying

More information

Digital Audio Design Validation and Debugging Using PGY-I2C

Digital Audio Design Validation and Debugging Using PGY-I2C Digital Audio Design Validation and Debugging Using PGY-I2C Debug the toughest I 2 S challenges, from Protocol Layer to PHY Layer to Audio Content Introduction Today s digital systems from the Digital

More information

Serial Decode I2C TEN MINUTE TUTORIAL. December 21, 2011

Serial Decode I2C TEN MINUTE TUTORIAL. December 21, 2011 Serial Decode I2C TEN MINUTE TUTORIAL December 21, 2011 Summary LeCroy oscilloscopes have the ability to trigger on and decode multiple serial data protocols. The decode in binary, hex, or ASCII format,

More information

TDSDVI DVI Compliance Test Solution

TDSDVI DVI Compliance Test Solution Online Help TDSDVI DVI Compliance Test Solution 077-0022-04 Adapted from TDSDVI Compliance Test Solution Online Help www.tektronix.com Copyright Tektronix. All rights reserved. Licensed software products

More information

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition INTRODUCTION Many sensors produce continuous voltage signals. In this lab, you will learn about some common methods

More information

Using Manchester and NRZ Configurable Protocol Decoders

Using Manchester and NRZ Configurable Protocol Decoders Using Manchester and NRZ Configurable Protocol Decoders TECHNICAL BRIEF March 14, 2013 Summary Manchester and NRZ encoding schemes serve as building blocks for industrystandard and custom protocols. Here

More information

FlexRay Measurements (Option FLX) for Agilent s InfiniiVision Series Oscilloscopes

FlexRay Measurements (Option FLX) for Agilent s InfiniiVision Series Oscilloscopes FlexRay Measurements (Option FLX) for Agilent s InfiniiVision Series Oscilloscopes Data Sheet Debug the physical layer characteristics of your FlexRay bus faster Introduction Agilent Technologies InfiniiVision

More information

Automated Limit Testing

Automated Limit Testing Automated Limit Testing Limit Testing with Tektronix DPO4000 and MSO4000 Series Oscilloscopes and National Instruments LabVIEW SignalExpress TE for Windows TM Introduction Automated limit testing allows

More information

Serial Triggering and Analysis Application Modules

Serial Triggering and Analysis Application Modules Serial Triggering and Analysis Application Modules AERO AUDIO AUTO AUTOMAX COMP EMBD FLEX Data Sheet Features & Benefits Automated Serial Triggering, Decode, and Search options for I 2 C, SPI, CAN, LIN,

More information

RS232 Decoding (Option)

RS232 Decoding (Option) bit0 bit1 bit2 bit3 bit4 bit5 bit6 bit7 bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0 7 Protocol Decoding RIGOL RS232 Decoding (Option) RS232 serial bus consists of the transmitting data line (TX) and the receiving

More information

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer Link Instruments Innovative Test & Measurement solutions since 1986 Store Support Oscilloscopes Logic Analyzers Pattern Generators Accessories MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer $ The

More information

User Manual. This document applies to firmware version 2.2 and above.

User Manual.  This document applies to firmware version 2.2 and above. User Manual CSA7000 Series Serial Mask Testing & Serial Pattern Trigger TDS6000 & TDS7000 Series Option SM Serial Mask Testing Option ST Serial Pattern Trigger 071-1035-02 This document applies to firmware

More information

PulseCounter Neutron & Gamma Spectrometry Software Manual

PulseCounter Neutron & Gamma Spectrometry Software Manual PulseCounter Neutron & Gamma Spectrometry Software Manual MAXIMUS ENERGY CORPORATION Written by Dr. Max I. Fomitchev-Zamilov Web: maximus.energy TABLE OF CONTENTS 0. GENERAL INFORMATION 1. DEFAULT SCREEN

More information

Keysight Technologies FlexRay Measurements (Option FLX) for Keysight s InfiniiVision Series Oscilloscopes. Data Sheet

Keysight Technologies FlexRay Measurements (Option FLX) for Keysight s InfiniiVision Series Oscilloscopes. Data Sheet Keysight Technologies FlexRay Measurements (Option FLX) for Keysight s InfiniiVision Series Oscilloscopes Data Sheet Introduction The Keysight Technologies, Inc. InfiniiVision Series oscilloscopes offer

More information

Serial Triggering and Analysis Applications. Bus display. Bus decoding. Key features. Results table. Wave Inspector search

Serial Triggering and Analysis Applications. Bus display. Bus decoding. Key features. Results table. Wave Inspector search 5 Series MSO Serial Triggering and Analysis Applications 5-SRAERO, 5-SRAUDIO, 5-SRAUTO, 5-SRAUTOSEN, 5-SRCOMP, and 5- SREMBD Datasheet Serial triggering Trigger on packet content such as start of packet,

More information

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier)

Quick Start for TrueRTA (v3.5) on Windows XP (and earlier) Skip directly to the section that covers your version of Windows (XP and earlier, Vista or Windows 7) Quick Start for TrueRTA (v3.5) on Windows XP (and earlier) Here are step-by-step instructions to get

More information

SigPlay User s Guide

SigPlay User s Guide SigPlay User s Guide . . SigPlay32 User's Guide? Version 3.4 Copyright? 2001 TDT. All rights reserved. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or

More information

Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster

Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster Application Note Introduction The primary reason engineers use oscilloscopes to debug and characterize automotive serial buses,

More information

System Requirements SA0314 Spectrum analyzer:

System Requirements SA0314 Spectrum analyzer: System Requirements SA0314 Spectrum analyzer: System requirements Windows XP, 7, Vista or 8: 1 GHz or faster 32-bit or 64-bit processor 1 GB RAM 10 MB hard disk space \ 1. Getting Started Insert DVD into

More information

Advanced Troubleshooting with Oscilloscopes 9000 Scope Hands-on Labs

Advanced Troubleshooting with Oscilloscopes 9000 Scope Hands-on Labs Advanced Troubleshooting with Oscilloscopes 9000 Scope Hands-on Labs Page Lab 1: Scope-based Protocol Analysis 2 Lab 2: Measurements & Analysis 10 Lab 3: InfiniiScan Zone-qualified Triggering 19 Lab 4:

More information

Keysight Technologies CAN/LIN Measurements (Option AMS) for InfiniiVision Series Oscilloscopes

Keysight Technologies CAN/LIN Measurements (Option AMS) for InfiniiVision Series Oscilloscopes Ihr Spezialist für Mess- und Prüfgeräte Keysight Technologies CAN/LIN Measurements (Option AMS) for InfiniiVision Series Oscilloscopes Data Sheet Introduction Debug the signal integrity of your CAN and

More information

Troubleshooting Your Design with Tektronix MSO and DPO Series Oscilloscopes

Troubleshooting Your Design with Tektronix MSO and DPO Series Oscilloscopes Troubleshooting Your Design with Tektronix 2 Table of Contents Troubleshooting Your Design with the MSO/DPO Series Oscilloscopes................. 4 Navigating Long Records.................................................

More information

MIPI DigRF 3G and v4 Decode

MIPI DigRF 3G and v4 Decode MIPI DigRF 3G and v4 Decode Key Features DigRF v4 Decodes Low-speed (26 Mb/s) Medium-speed (1248 Mb/s) High-speed (1456 Mb/s) View an entire DigRF 3G burst using intuitive decoding and table display. Click

More information

Using SignalTap II in the Quartus II Software

Using SignalTap II in the Quartus II Software White Paper Using SignalTap II in the Quartus II Software Introduction The SignalTap II embedded logic analyzer, available exclusively in the Altera Quartus II software version 2.1, helps reduce verification

More information

Low-speed serial buses are used in wide variety of electronics products. Various low-speed buses exist in different

Low-speed serial buses are used in wide variety of electronics products. Various low-speed buses exist in different Low speed serial buses are widely used today in mixed-signal embedded designs for chip-to-chip communication. Their ease of implementation, low cost, and ties with legacy design blocks make them ideal

More information

BusFinder Series. LA3000 Series 2 in 1 Analyzer (Protocol + Logic) Manual

BusFinder Series. LA3000 Series 2 in 1 Analyzer (Protocol + Logic) Manual BusFinder Series. LA3000 Series 2 in 1 Analyzer (Protocol + Logic) Manual Publish: 2018/06 1 Table of Contents Chapter 1 Installation and Setting... 4 Hardware Installation... 4 Appearance and Functions

More information

EAN-Performance and Latency

EAN-Performance and Latency EAN-Performance and Latency PN: EAN-Performance-and-Latency 6/4/2018 SightLine Applications, Inc. Contact: Web: sightlineapplications.com Sales: sales@sightlineapplications.com Support: support@sightlineapplications.com

More information

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

NanoGiant Oscilloscope/Function-Generator Program. Getting Started Getting Started Page 1 of 17 NanoGiant Oscilloscope/Function-Generator Program Getting Started This NanoGiant Oscilloscope program gives you a small impression of the capabilities of the NanoGiant multi-purpose

More information

PCIe: EYE DIAGRAM ANALYSIS IN HYPERLYNX

PCIe: EYE DIAGRAM ANALYSIS IN HYPERLYNX PCIe: EYE DIAGRAM ANALYSIS IN HYPERLYNX w w w. m e n t o r. c o m PCIe: Eye Diagram Analysis in HyperLynx PCI Express Tutorial This PCI Express tutorial will walk you through time-domain eye diagram analysis

More information

APPLICATION NOTE 4254 PRBS Mode Setup for the MAX9257/MAX9258 Evaluation Kit

APPLICATION NOTE 4254 PRBS Mode Setup for the MAX9257/MAX9258 Evaluation Kit Maxim > Design Support > Technical Documents > Application Notes > High-Speed Interconnect > APP 4254 Keywords: PRBS, pseudo-random bit sequence, serializer, deserializer, eye diagram, ECU, bit error rate

More information

Troubleshooting Your Design with the TDS3000C Series Oscilloscopes

Troubleshooting Your Design with the TDS3000C Series Oscilloscopes Troubleshooting Your Design with the 2 Table of Contents Getting Started........................................................... 4 Debug Digital Timing Problems...............................................

More information

PicoScope 6 Training Manual

PicoScope 6 Training Manual PicoScope 6 Training Manual DO226 PicoScope 6 Training Manual r2.docx Copyright 2014 Pico Technology CONTENTS 1 Quick guide to PicoScope 6... 1 1.1 The PicoScope way... 1 1.2 Signal view... 2 1.3 Timebase...

More information

Manual Version Ver 1.0

Manual Version Ver 1.0 The BG-3 & The BG-7 Multiple Test Pattern Generator with Field Programmable ID Option Manual Version Ver 1.0 BURST ELECTRONICS INC CORRALES, NM 87048 USA (505) 898-1455 VOICE (505) 890-8926 Tech Support

More information

DSA8300 DigitalSerialAnalyzer Printable Application Help

DSA8300 DigitalSerialAnalyzer Printable Application Help xx ZZZ DSA8300 DigitalSerialAnalyzer Printable Application Help *P077056904* 077-0569-04 ZZZ DSA8300 Digital Serial Analyzer Printable Application Help www.tek.com 077-0569-04 Copyright Tektronix. All

More information

Choosing an Oscilloscope

Choosing an Oscilloscope Choosing an Oscilloscope By Alan Lowne CEO Saelig Company (www.saelig.com) Post comments on this article at www.nutsvolts.com/ magazine/article/october2016_choosing-oscilloscopes. All sorts of questions

More information

Embest DSO2300. Feature. General Description:

Embest DSO2300. Feature. General Description: Embest DSO2300 Feature General Description: DSO2300 is an intelligent two-channel PC based USB digital storage oscilloscope with high performance. It runs on any USB1.1 or USB2.0 equipped PC using Windows

More information

Getting Started with the LabVIEW Sound and Vibration Toolkit

Getting Started with the LabVIEW Sound and Vibration Toolkit 1 Getting Started with the LabVIEW Sound and Vibration Toolkit This tutorial is designed to introduce you to some of the sound and vibration analysis capabilities in the industry-leading software tool

More information

ENGR 1000, Introduction to Engineering Design

ENGR 1000, Introduction to Engineering Design ENGR 1000, Introduction to Engineering Design Unit 2: Data Acquisition and Control Technology Lesson 2.4: Programming Digital Ports Hardware: 12 VDC power supply Several lengths of wire NI-USB 6008 Device

More information

Lab experience 1: Introduction to LabView

Lab experience 1: Introduction to LabView Lab experience 1: Introduction to LabView LabView is software for the real-time acquisition, processing and visualization of measured data. A LabView program is called a Virtual Instrument (VI) because

More information

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules DT9834 Series High-Performance Multifunction USB Data Acquisition Modules DT9834 Series High Performance, Multifunction USB DAQ Key Features: Simultaneous subsystem operation on up to 32 analog input channels,

More information

Operating Instructions

Operating Instructions Operating Instructions HAEFELY TEST AG KIT Measurement Software Version 1.0 KIT / En Date Version Responsable Changes / Reasons February 2015 1.0 Initial version WARNING Introduction i Before operating

More information

Oscilloscope Reference Manual CS300

Oscilloscope Reference Manual CS300 Oscilloscope Reference Manual CS300 Cleverscope Models: CS320 CS328 CS320A CS328A CS320AE CS328AE CS320A-XS CS320-XSE v 2.11.2 16 Jul 2015 Cleverscope CS300 Reference Manual v2.11 Page 2 www.cleverscope.com

More information

Meeting Embedded Design Challenges with Mixed Signal Oscilloscopes

Meeting Embedded Design Challenges with Mixed Signal Oscilloscopes Meeting Embedded Design Challenges with Mixed Signal Oscilloscopes Introduction Embedded design and especially design work utilizing low speed serial signaling is one of the fastest growing areas of digital

More information

WCS-D800 Programming Software for the Icom ID-800

WCS-D800 Programming Software for the Icom ID-800 for the Icom ID-800 Memory Types Memories Limit Memories VFO Call Channels Receive Frequency Name Show Name Rx Memory Channel Functions TX Power Skip Bank Comments The WCS-D800 Programmer is designed to

More information

Oscilloscope Reference Manual CS300

Oscilloscope Reference Manual CS300 Oscilloscope Reference Manual CS300 Cleverscope Models: CS320 CS328 CS320A CS328A CS320AE CS328AE CS320A-XS CS320-XSE v 2.12.0 31 May 2016 Cleverscope CS300 Reference Manual v2.11 Page 2 www.cleverscope.com

More information

WCS-V82 Programming Software for the Icom IC-V82

WCS-V82 Programming Software for the Icom IC-V82 for the Icom IC-V82 Memory Types Memories Limit Memories Call Channel Memory Channel Functions Polarity Skip Bank The WCS-V82 Programmer is designed to give you the ease and convenience of programming

More information

E X P E R I M E N T 1

E X P E R I M E N T 1 E X P E R I M E N T 1 Getting to Know Data Studio Produced by the Physics Staff at Collin College Copyright Collin College Physics Department. All Rights Reserved. University Physics, Exp 1: Getting to

More information

LeCroy Digital Oscilloscopes

LeCroy Digital Oscilloscopes LeCroy Digital Oscilloscopes Get the Complete Picture Quick Reference Guide QUICKSTART TO SIGNAL VIEWING Quickly display a signal View with Analog Persistence 1. Connect your signal. When you use a probe,

More information

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix v1.2 Burlington County College INSTRUCTION GUIDE for the Hewlett Packard FUNCTION GENERATOR Model #33120A and Tektronix OSCILLOSCOPE Model #MSO2004B Summer 2014 Pg. 2 Scope-Gen Handout_pgs1-8_v1.2_SU14.doc

More information

LMH0340/LMH0341 SerDes EVK User Guide

LMH0340/LMH0341 SerDes EVK User Guide LMH0340/LMH0341 SerDes EVK User Guide July 1, 2008 Version 1.05 1 1... Overview 3 2... Evaluation Kit (SD3GXLEVK) Contents 3 3... Hardware Setup 4 3.1 ALP100 BOARD (MAIN BOARD) DESCRIPTION 5 3.2 SD340EVK

More information

Analyzing 8b/10b Encoded Signals with a Real-time Oscilloscope Real-time triggering up to 6.25 Gb/s on 8b/10b encoded data streams

Analyzing 8b/10b Encoded Signals with a Real-time Oscilloscope Real-time triggering up to 6.25 Gb/s on 8b/10b encoded data streams Presented by TestEquity - www.testequity.com Analyzing 8b/10b Encoded Signals with a Real-time Oscilloscope Real-time triggering up to 6.25 Gb/s on 8b/10b encoded data streams Application Note Application

More information

Viewing Serial Data on the Keysight Oscilloscopes

Viewing Serial Data on the Keysight Oscilloscopes Ming Hsieh Department of Electrical Engineering EE 109L - Introduction to Embedded Systems Viewing Serial Data on the Keysight Oscilloscopes by Allan G. Weber 1 Introduction The four-channel Keysight (ex-agilent)

More information

PicoScope 6. PC Oscilloscope Software. User's Guide. psw.en r37 Copyright Pico Technology Ltd. All rights reserved.

PicoScope 6. PC Oscilloscope Software. User's Guide. psw.en r37 Copyright Pico Technology Ltd. All rights reserved. PicoScope 6 PC Oscilloscope Software User's Guide PicoScope 6 User's Guide I Table of Contents 1 Welcome...1 2 PicoScope 6...2 overview 3 Introduction...3 1 Legal statement...3 2 Upgrades...3 3 Trade

More information

Table of Contents Introduction

Table of Contents Introduction Page 1/9 Waveforms 2015 tutorial 3-Jan-18 Table of Contents Introduction Introduction to DAD/NAD and Waveforms 2015... 2 Digital Functions Static I/O... 2 LEDs... 2 Buttons... 2 Switches... 2 Pattern Generator...

More information

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors. Brüel & Kjær Pulse Primer University of New South Wales School of Mechanical and Manufacturing Engineering September 2005 Prepared by Michael Skeen and Geoff Lucas NOTICE: This document is for use only

More information

MSO/DPO Series Oscilloscopes. Feature-rich tools for debugging mixed signal designs

MSO/DPO Series Oscilloscopes. Feature-rich tools for debugging mixed signal designs MSO/DPO Series Oscilloscopes Feature-rich tools for debugging mixed signal designs MSO/DPO Series Oscilloscopes Analyze Analog and Digital Signals with a Single Instrument 4000 Series 3000 Series 2000

More information

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

Oscilloscope Guide Tektronix TDS3034B & TDS3052B Tektronix TDS3034B & TDS3052B Version 2008-Jan-1 Dept. of Electrical & Computer Engineering Portland State University Copyright 2008 Portland State University 1 Basic Information This guide provides basic

More information

Logic Analysis Basics

Logic Analysis Basics Logic Analysis Basics September 27, 2006 presented by: Alex Dickson Copyright 2003 Agilent Technologies, Inc. Introduction If you have ever asked yourself these questions: What is a logic analyzer? What

More information

SignalTap Plus System Analyzer

SignalTap Plus System Analyzer SignalTap Plus System Analyzer June 2000, ver. 1 Data Sheet Features Simultaneous internal programmable logic device (PLD) and external (board-level) logic analysis 32-channel external logic analyzer 166

More information

Logic Analysis Basics

Logic Analysis Basics Logic Analysis Basics September 27, 2006 presented by: Alex Dickson Copyright 2003 Agilent Technologies, Inc. Introduction If you have ever asked yourself these questions: What is a logic analyzer? What

More information

DVR-431 USB Wireless Receiver User Manual

DVR-431 USB Wireless Receiver User Manual DVR-431 USB Wireless Receiver User Manual Thank you for using our wireless USB receiver, please read the following content carefully before using, it will help you make better use of this product. Introduction

More information

SignalTap: An In-System Logic Analyzer

SignalTap: An In-System Logic Analyzer SignalTap: An In-System Logic Analyzer I. Introduction In this chapter we will learn 1 how to use SignalTap II (SignalTap) (Altera Corporation 2010). This core is a logic analyzer provided by Altera that

More information

Network Line Card Testing using the TDS3000B DPO Application Note. Line Card Testing Example: Throughput = Shippable Dollars

Network Line Card Testing using the TDS3000B DPO Application Note. Line Card Testing Example: Throughput = Shippable Dollars Testing Example: Throughput = Shippable Dollars Overall manufacturing test throughput is dependent on many factors. Figure 1 shows a typical line card test setup using an oscilloscope, a channel multiplexer,

More information

Analyzing and Saving a Signal

Analyzing and Saving a Signal Analyzing and Saving a Signal Approximate Time You can complete this exercise in approximately 45 minutes. Background LabVIEW includes a set of Express VIs that help you analyze signals. This chapter teaches

More information

Viewing Serial Data on the Keysight Oscilloscopes

Viewing Serial Data on the Keysight Oscilloscopes Ming Hsieh Department of Electrical Engineering EE 109L - Introduction to Embedded Systems Viewing Serial Data on the Keysight Oscilloscopes by Allan G. Weber 1 Introduction The four-channel Keysight (ex-agilent)

More information

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display.

Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display. Configuring the Stack ST8961 VS Module when used in conjunction with a Stack ST81xx series display. Your Stack ST8961 VS module allows you to synchronize, overlay, and record data available on your Stack

More information

The BAT WAVE ANALYZER project

The BAT WAVE ANALYZER project The BAT WAVE ANALYZER project Conditions of Use The Bat Wave Analyzer program is free for personal use and can be redistributed provided it is not changed in any way, and no fee is requested. The Bat Wave

More information

RS-232/UART Triggering and Hardware-Based Decode (N5457A) for Agilent InfiniiVision Oscilloscopes

RS-232/UART Triggering and Hardware-Based Decode (N5457A) for Agilent InfiniiVision Oscilloscopes Find and debug intermittent errors and signal integrity problems faster RS-232/UART Triggering and Hardware-Based Decode (N5457A) for Agilent InfiniiVision Oscilloscopes Data Sheet Features: RS-232/UART

More information

PicoScope 6 Beta. PC Oscilloscope Software. User's Guide. psw.beta.en r35 Copyright Pico Technology Ltd. All rights reserved.

PicoScope 6 Beta. PC Oscilloscope Software. User's Guide. psw.beta.en r35 Copyright Pico Technology Ltd. All rights reserved. PicoScope 6 Beta PC Oscilloscope Software User's Guide PicoScope 6 Beta User's Guide I Table of Contents 1 Welcome...1 2 PicoScope 6...2 overview 3 Introduction...3 1 Legal statement 2 Upgrades 3 Trade

More information

Debugging Memory Interfaces using Visual Trigger on Tektronix Oscilloscopes

Debugging Memory Interfaces using Visual Trigger on Tektronix Oscilloscopes Debugging Memory Interfaces using Visual Trigger on Tektronix Oscilloscopes Application Note What you will learn: This document focuses on how Visual Triggering, Pinpoint Triggering, and Advanced Search

More information

Calibrating Measuring Microphones and Sound Sources for Acoustic Measurements with Audio Analyzer R&S UPV

Calibrating Measuring Microphones and Sound Sources for Acoustic Measurements with Audio Analyzer R&S UPV Product: R&S UPV Calibrating Measuring Microphones and Sound Sources for Acoustic Measurements with Audio Analyzer R&S UPV Application Note 1GA47_0E This application note explains how to use acoustic calibrations

More information

Expect to Make Waves.

Expect to Make Waves. Expect to Make Waves. The New Oscilloscope Large 10.4" LCD touch screen Long capture time Extensive communication capabilities www.lecroy.com The New Oscillos From its large 10.4" LCD touch screen to its

More information

C-PHY Essentials Transmitter Test Solution TekExpress C-PHY Essentials Tx

C-PHY Essentials Transmitter Test Solution TekExpress C-PHY Essentials Tx C-PHY Essentials Transmitter Test Solution TekExpress C-PHY Essentials Tx Applications Camera CMOS Image sensors Display Driver ICs Application processor for Mobile devices Tektronix C-PHY TX Essentials

More information

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003 OBJECTIVE To become familiar with state-of-the-art digital data acquisition hardware and software. To explore common data acquisition

More information

Logic Analyzer Auto Run / Stop Channels / trigger / Measuring Tools Axis control panel Status Display

Logic Analyzer Auto Run / Stop Channels / trigger / Measuring Tools Axis control panel Status Display Logic Analyzer The graphical user interface of the Logic Analyzer fits well into the overall design of the Red Pitaya applications providing the same operating concept. The Logic Analyzer user interface

More information

Advanced Skills with Oscilloscopes

Advanced Skills with Oscilloscopes Advanced Skills with Oscilloscopes A Hands On Laboratory Guide to Oscilloscopes using the Rigol DS1104Z By: Tom Briggs, Department of Computer Science & Engineering Shippensburg University of Pennsylvania

More information

CI-218 / CI-303 / CI430

CI-218 / CI-303 / CI430 CI-218 / CI-303 / CI430 Network Camera User Manual English AREC Inc. All Rights Reserved 2017. l www.arec.com All information contained in this document is Proprietary Table of Contents 1. Overview 1.1

More information

Instruction Manual. USB3.0bus Decoder Software

Instruction Manual. USB3.0bus Decoder Software Instruction Manual USB3.0bus Decoder Software USB3.0bus Decoder Software Instruction Manual 2017 Teledyne LeCroy, Inc. All rights reserved. Unauthorized duplication of Teledyne LeCroy, Inc. documentation

More information

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ Products: AMIQ, SMIQ AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ The software AMIQ-K2 enables you to read, convert, and transfer various-format I/Q data files to AMIQ format. AMIQ-K2

More information

Defining and Labeling Circuits and Electrical Phasing in PLS-CADD

Defining and Labeling Circuits and Electrical Phasing in PLS-CADD 610 N. Whitney Way, Suite 160 Madison, WI 53705 Phone: 608.238.2171 Fax: 608.238.9241 Email:info@powline.com URL: http://www.powline.com Defining and Labeling Circuits and Electrical Phasing in PLS-CADD

More information

Cisco Spectrum Expert Software Overview

Cisco Spectrum Expert Software Overview CHAPTER 5 If your computer has an 802.11 interface, it should be enabled in order to detect Wi-Fi devices. If you are connected to an AP or ad-hoc network through the 802.11 interface, you will occasionally

More information

Boonton 4540 Remote Operation Modes

Boonton 4540 Remote Operation Modes Application Note Boonton 4540 Remote Operation Modes Mazumder Alam Product Marketing Manager, Boonton Electronics Abstract Boonton 4540 series power meters are among the leading edge instruments for most

More information

User manual. English. Perception CSI Extension Harmonic Analysis Sheet. A en

User manual. English. Perception CSI Extension Harmonic Analysis Sheet. A en A4192-2.0 en User manual English Perception CSI Extension Document version 2.0 February 2015 For Harmonic Analysis version 2.0.15056 For Perception 6.60 or higher For HBM's Terms and Conditions visit www.hbm.com/terms

More information

Any feature not specifically noted as supported is not supported.

Any feature not specifically noted as supported is not supported. Manufacturer: ELAN Integration Note Model Number(s): EL-4KM-VW44 (Device Ver 2.20; Web Module Ver 6.23) Minimum Core Module Version: Document Revision Date: 8.1.395 5/11/2017 OVERVIEW AND SUPPORTED FEATURES

More information

VIDEOPOINT CAPTURE 2.1

VIDEOPOINT CAPTURE 2.1 VIDEOPOINT CAPTURE 2.1 USER GUIDE TABLE OF CONTENTS INTRODUCTION 2 INSTALLATION 2 SYSTEM REQUIREMENTS 3 QUICK START 4 USING VIDEOPOINT CAPTURE 2.1 5 Recording a Movie 5 Editing a Movie 5 Annotating a Movie

More information

Remote Application Update for the RCM33xx

Remote Application Update for the RCM33xx Remote Application Update for the RCM33xx AN418 The common method of remotely updating an embedded application is to write directly to parallel flash. This is a potentially dangerous operation because

More information

PQ-Box 100 Quick Start Instructions

PQ-Box 100 Quick Start Instructions PQ-Box 100 Quick Start Instructions These instructions are provided for the purpose on providing a quick start to PQ-Box 100 installation and operation. Please refer to the user handbook for full details.

More information

Keysight Technologies Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster. Application Note

Keysight Technologies Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster. Application Note Keysight Technologies Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster Application Note Introduction The primary reason engineers use oscilloscopes to debug and characterize

More information

SpikePac User s Guide

SpikePac User s Guide SpikePac User s Guide Updated: 7/22/2014 SpikePac User's Guide Copyright 2008-2014 Tucker-Davis Technologies, Inc. (TDT). All rights reserved. No part of this manual may be reproduced or transmitted in

More information

EEG A1452 SCTE-104 Inserter Frame Card

EEG A1452 SCTE-104 Inserter Frame Card EEG A1452 SCTE-104 Inserter Frame Card Product Manual EEG Enterprises, Inc. 586 Main Street Farmingdale, New York 11735 TEL: (516) 293-7472 FAX: (516) 293-7417 Copyright EEG Enterprises, Inc. 2017 All

More information

X-Stream DSO Version 3.6 Release Notes

X-Stream DSO Version 3.6 Release Notes X-Stream DSO Version 3.6 Release Notes probe calibration and deskew fixture This release contains support for LeCroy s new TF-DSQ option. The fixture enables DC gain, offset, and skew calibration at the

More information

Oscilloscopes, logic analyzers ScopeLogicDAQ

Oscilloscopes, logic analyzers ScopeLogicDAQ Oscilloscopes, logic analyzers ScopeLogicDAQ ScopeLogicDAQ 2.0 is a comprehensive measurement system used for data acquisition. The device includes a twochannel digital oscilloscope and a logic analyser

More information

Experiment # 4 Counters and Logic Analyzer

Experiment # 4 Counters and Logic Analyzer EE20L - Introduction to Digital Circuits Experiment # 4. Synopsis: Experiment # 4 Counters and Logic Analyzer In this lab we will build an up-counter and a down-counter using 74LS76A - Flip Flops. The

More information