1 The MTS FiON Network for Multiple Dwelling Units (MDUs) Greenfield/Brownfield Renovations

2 Table of Contents We ve Upgraded our Network... 1 MTS Fibre Optics Installation Guidelines... 2 MTS Fibre Optics In-Building Installation Guidelines MTS Fibre Optics In-Suite Equipment MTS Fibre Optics Main Telephone Room (MTR) Equipment MTS In-Suite Prewiring Guidelines MTS In-Suite MDU Guidelines Wiring Configuration Glossary of Acronyms Waiver of Responsibility Contact Numbers

3 We ve upgraded our network! Welcome to the next generation in network technology. In order to provide owners of MDUs (Building Owners) with advanced service offerings in the future, we are investing in a next generation fibre network in your neighbourhood. This network supplies a huge amount of bandwidth into the MDU which means the occupants of the MDU (Residents) can expect higher quality and more reliable Home Phone, High Speed Internet and TV services, now and in the future. In addition, with the MTS FiON Network, the MDU will also be in a perfect position to meet the Residents evolving telecommunication needs due to the significantly increased bandwidth available to each suite in the MDU on the network. The launch of the MTS FiON Network in the MDU also means that the Residents will now be eligible for the next generation of high definition television MTS Ultimate TV service. With Ultimate TV, MTS customers have access to exciting new features such as high quality HD programming, our Whole Home PVR service, and our Interactive Program Guide. In addition, the MTS FiON Network provides the Residents with its fastest broadband connections available, enabling the development of new High Speed Internet plans exclusive to the new network. With the MTS FiON Network, the MDU will be set up for the long term as additional wiring upgrades will likely not be required for a long time. The MDU will be in a perfect position to access the newest MTS products and services as they are launched. Visit mts.ca/fion for details. 1

4 MTS Fibre Optics Installation Guidelines for Greenfield (new) and Brownfield Renovation (existing under renovation) Multiple Dwelling Units (MDU) A Multi Dwelling Unit (MDU) is defined as: apartment block condominium buildings with 5 or more suites in a single property (fed by one shared drop/cable per MDU) MTS is deploying a new fibre optic network based on Passive Optical Network technology, or PON, to deliver High Speed Internet, TV and Home Phone services under the MTS FiON Network brand name. In order to deliver this service, MTS will supply a fibre optic cable to each suite in the MDU. The single fibre cable will be used to support all MTS FiON Network branded services (such as MTS Ultimate TV, High Speed Internet, and Home Phone) to the suite s occupant. Purpose of this document To provide Building Owners with information and general guidelines required to support an MTS fibre in-building riser installation. These guidelines apply: During the design phase for Low Voltage conduit (pathway) and cabling to support the MTS FiON Network For buildings under construction where in-building riser systems or pathways are accessible to all suites in the MDUs this includes all pathways to areas such as entrance systems, common area HSI or TV services, alarm services or Lobby Cam services, including Elevator Phone service in the MDU where MTS provides the MTS FiON Network This document will serve as a general guideline for the installation of MTS in-building fibre material and equipment. Please contact MTS at or to arrange a meeting and/or site visit to discuss details and exact requirements for installing MTS FiON in the MDU. 2

5 Figure 1 In-Suite Distribution Box (IDB) MTS Fibre ONT & Power Supply mounted near MPLS (outside IDB) Riser conduit (option) Electrical outlet MPLS plate Wall finish (drywall/other) Electical box (4 x 4 ) In-suite Distribution Box & Door 14.5 (37 cm) width 14 (35.5 cm) height 4.5 (11.3 cm) depth* SOHO MTS Fibre Optic In-Building Installation Guidelines Introduction Fibre to the Home is a new technology that uses fibre optic cable instead of the traditional copper wiring to deliver services to the suite (Voice, High Speed Internet, and TV). The Fibre Optic network is connected to the copper wiring inside the suite by a device called an Optical Network Terminal (ONT). The ONT converts the fibre optic signal so that it can be distributed over the in-suite wiring. Description 14.5 spacing Height from floor 48 (min) Wood/Metal studding *Standard 2 X 4 stud depth. Figure 2 In-Suite Distribution Box (IDB) MTS Fibre equipment mounted inside IDB Riser conduit (option) Wall finish Electical box (4 x 4 ) Door Clearance 16 (40.6 cm) In-suite Distribution Box & Door 14.5 (37 cm) width 30 (72.2 cm) height 4.5 (11.3 cm) depth* Electrical outlets (2) mounted inside box MTS fibre optic in-building installation service is available to MDU Building Owners where a Pre-Wire Installation and Maintenance Agreements (Access and Fibre) are in place with MTS indicating that ownership of the fibre material and equipment will remain with MTS. Under this agreement, MTS will be responsible for providing and installing all fibre material and MTS equipment to the entrance of each suite. This includes maintenance of the fibre entering the suite (commonly referred to as the in-building riser wiring). Where access to the building riser (or pathway) is not available in existing MDUs under renovation, MTS will work with the Building Owner to design a solution for the riser pathway. Several design and installation solutions are available to Building Owners that will vary depending on the age, type, size and construction material used to construct your MDU. For more information on the required agreements and installation service available to Building Owners, please contact MTS at or or visit Notes: Wood/Metal studding 14.5 spacing Height from floor 48 (min) *Standard 2 X 4 stud depth. Please note: MTS will also provide smaller in-suite distribution boxes where spacing is limited inside the mounting area or where surface mounted distribution boxes cannot be supported. Please contact MTS Consumer Public Access at / for further information. T he Building Owner is responsible for providing MTS with access to the Main Telephone Room (MTR) in the MDU, secondary communication rooms and for the installation of the in-building riser space (pathways) or conduit required to service each suite. The Building Owner is responsible for providing MTS access to all suites in the MDU. Buildings Owners are responsible for providing in-building riser wiring (such as copper or coax wiring) where Residents subscribe to services provided by other telecommunication service providers. The fibre optic material and equipment installed by MTS remains the exclusive property of MTS. 10 3

6 In-Suite Equipment The ONT is powered by an Uninterrupted Power Supply (UPS) that also provides power for emergency service in the event of an AC power outage. The wall mounted ONT must be a minimum of 1 inch (2.5 cm) from any obstruction and mounted a minimum of 5 inches (12.5 cm) from the finished floor height and/or connecting wall. The UPS must be mounted a minimum of 1 inch (2.5 cm) from any obstruction and between 3-4 inches (7.5 and 10 cm) from the ONT and mounted such that the Resident can replace the battery inside the UPS when required. The UPS requires a standard grounded 3 prong non-gfci 120V 60Hz outlet within 6 feet (1.83m) of where the ONT is mounted. The required spacing to support the installation of the ONT and UPS is typically 28 inches (71 cm) in width and 19 inches (48 cm) in height. If an in-suite distribution box (IDB) is being installed to support the installation of the ONT and UPS it must have a minimum of 6 inches (15 cm) unobstructed airspace in the front, above, and below all surfaces in a minimum area of a 3ft x 6ft x 7ft (90 cm x 180 cm x 210 cm) (D x W x H) room and requires 15 (38cm) clearance to open the access door. Any communication termination blocks located in the suite Utility Room must be placed no closer then 900mm from any AC breaker/fuse panels in said room. Exceptions to this requirement, must be discussed and agreed to by a MTS representative. Please note, the Building Owner must provide two standard non- GFCI AC power receptacles (providing four available AC outlets) installed inside the IDB. Both pairs of outlets should be on a single, dedicated 15A branch circuit to prevent disruption of service. For further details relating to the IDB please refer to the MTS In-Suite Pre-Wiring Guidelines section. Additional equipment MTS services such as High Speed Internet or Ultimate TV will require a router and/or TV Set-Top-Box(es). 4

7 Main Telephone Room (MTR) Equipment MTS will install a Fibre Distribution Terminal (FDT) in the MTR to connect the building entrance fibres installed by MTS to each in-building fibre drop cable that will be installed to each suite. The FDT can be up to 52 inches wide by 21 inches (130 cm by 52.5 cm) in height and will require 52 inches (130 cm) clearance to open the access door as shown below. MTS Fibre Distribution Terminal (FDT) mounted in Main Telephone Room (MTR) or Secondary Riser Room. Plywood mounting area 55 (139.7 cm) width (max) 24 (60 cm) height (max) 1/2 (1.25 cm) depth (max) Fibre Distribution Terminal (FDT) with locking door 52 (130 cm) width (max) 21 (52.5 cm) height (max) 18 (45.7cm) dept h(max) Door Opening 52 (130 cm) clearance Please note: Plywood mounting area for MTS equipment may increase where Building Owners provide Elevator Phone, Enterphone systems or Common Area HSI or TV services to their tenants, including electrical power required to service the additional MTS equipment. The MDU may also require additional FDTs that are up to 30 inches wide by 20 inches (75 cm by 50 cm) in height in different areas of your MDU (such as secondary communication rooms on upper floors) and 30 (75cm) clearance to open the door. 5

8 Notes: The FDT(s) required for the MDU may need to be connected to a common building ground. When grounding is required, the preferred method is to attach to the main building ground. Electrical power is not required to support the installation of the Fibre Distribution Terminal(s). MTS will require easy access by a Field Service Technician to service and/or fulfill new and existing customer requests for MTS FiON Network services. Please contact MTS to discuss cabling and electrical power requirements for additional services such as entrance systems, common area HSI or TV services, Main floor alarm, Lobby Cam services and Elevator Phone service in the MDU. This Fibre Optic Installation guideline is provided to Residential MDU Owners for informational purposes only. Building Owners should contact MTS at or for additional details. 6

9 MTS In-Suite Pre-Wiring Guidelines Purpose of this section To provide in-suite pre-wiring guidelines that supports communications cabling for MTS TV, High Speed Internet and Home Phone services within MDUs. This guide applies to all MDUs under construction where in-suite wiring pathways are accessible in all suites. Material Guidelines: All materials must meet a minimum of ANSI/TIA/EIA-568-B.1, Commercial Building Telecommunications Cabling Standards All cables used must have proven industry performance. The following communications cabling (hereafter referred to as cabling) must be used in all pre-wired suites: Minimum Cat 5e for digital TV/HSI services and voice services (Cat 5e must be compliant with the ANSI/TIA/EIA-568-B.1 standard) RG6 Coax for TV broadband All cable must be FT4/CMR or FT6/CMP rated as required. General Wiring Guidelines Cabling must be run separately from electrical services and must conform to the latest CSA, Canadian Electrical Code, Manitoba Electrical Code and Local Building Codes standards. Cabling must not run in the same joist/stud holes as electrical wires. Cabling can run through an individually drilled or a common hole. The diameter of the hole must be at least ¼ or 6.5 mm wider than the bundle of cables to be run though it. Cabling must not be subjected to any of the following conditions: Walked on or exposed to any physical compression. Exposed to any chemicals including any type of paint including overspray. Handled or placed at temperatures below manufacture recommendation (typically 5 degrees Celsius). Kinked and then straightened. Pulled around, over or through any rough or sharp surface Exceed maximum pulling tension 25 foot lbs for Cat 5e and 80 foot lbs for RG6. Ensure minimal bend radius does not exceed 4 times outside diameter of cable. 7

10 Cables must be home run to an in-suite distribution box (IDB) or to a central wiring point in the suite (typically located in a laundry or utility room). Cables must never be daisy-chained. Three feet or 90 cm of slack must be left in the in-suite distribution box for the installer to terminate the cable runs. Cables must not come within 2 inches or 50 mm of unprotected high voltage cables (110V and greater). Cable is considered protected if separated from high voltage cables by properly grounded BX or metallic conduit. Cables must not be run in hot or cold air ducts. All cables must be labeled so the in-suite outlet location can be determined. Cables must be labeled while they are being run (not afterwards). Cables must be marked with proper wire tags rather than pieces of electrical tape, masking tape, nicks, etc. All cable runs must be on a grid pattern and not by line of sight or shortest route. When cables are run parallel to floor joist or beams, they must be properly secured (by stapling, etc.) at an interval equal to the stapler length. Vertical cable runs to the electrical boxes or MPLS plate must be attached to the studding so that the cables will not be pulled out by the other trades when they are insulating or working in the general area. After all cables are run back to the in-suite distribution box, they must be neatly coiled up and secured in the distribution box to protect from any damage. The distribution box must remain covered at all times during construction with a protective material, such as plastic, to protect cables from any chemicals such as paint (paint will immediately degrade the performance of the cable sheath). 8

11 Electrical Box/MPLS Plate Guidelines: All electrical boxes or MPLS plates used for communications cabling locations must be installed at the standard height above the floor per the Canadian Electrical Code. Electrical boxes must be installed at the proper depth on studs for the appropriate dry wall that will be installed. If an electrical box is installed on an outside wall, a vapor barrier such as Iberville Model VB1-CRT or equivalent must be installed at the time of pre-wire. At each pre-wired outlet location, there must be 2 electrical boxes installed per the following two scenarios: A wall stud with one electrical box located on each side (one for communications cabling and one for electrical to power devices) If using two wall studs, the electrical boxes must be located in the same air space between the two studs. MTS MDU Pre-Wiring Guidelines An in-suite distribution box is required in each suite to serve as a cross-connect location between in-suite wiring and the communication riser. MTS will provide one in-suite distribution box for each suite if required. The in-suite distribution box is typically installed by the electrician and the typical location is the in-suite laundry room. Drawing of the two (2) styles of in-suite distribution boxes available for installation are shown in Figure 1 and Figure 2. All in-suite cables from each outlet/mpls location must be home run back to an In-Suite Distribution Box (IDB). A typical in-suite wiring diagram is provided in Figure 3. 9

12 Figure 1 In-Suite Distribution Box (IDB) MTS Fibre ONT & Power Supply mounted near MPLS (outside IDB) Riser conduit (option) Electrical outlet MPLS plate Wall finish (drywall/other) Electical box (4 x 4 ) In-suite Distribution Box & Door 14.5 (37 cm) width 14 (35.5 cm) height 3.5 (8.8 cm) depth* SOHO MTS Fibre Optic In-Building Installation Guidelines Introduction Fibre to the Home is a new technology that uses fibre optic cable instead of the traditional copper wiring to deliver services to the suite (Voice, High Speed Internet, and TV). The Fibre Optic network is connected to the copper wiring inside the suite by a device called an Optical Network Terminal (ONT). The ONT converts the fibre optic signal so that it can be distributed over the in-suite wiring. Description 14.5 spacing Height from floor 48 (min) Wood/Metal studding *Standard 2 X 4 stud depth. Figure 2 In-Suite Distribution Box (IDB) MTS Fibre equipment mounted inside IDB Riser conduit (option) Wall finish Electical box (4 x 4 ) Door Clearance 16 (40.6 cm) In-suite Distribution Box & Door 14.5 (37 cm) width 30 (72.2 cm) height 3.5 (8.8 cm) depth* Electrical outlets (2) mounted inside box MTS fibre optic in-building installation service is available to MDU Building Owners where a Pre-Wire Installation and Maintenance Agreements (Access and Fibre) are in place with MTS indicating that ownership of the fibre material and equipment will remain with MTS. Under this agreement, MTS will be responsible for providing and installing all fibre material and MTS equipment to the entrance of each suite. This includes maintenance of the fibre entering the suite (commonly referred to as the in-building riser wiring). Where access to the building riser (or pathway) is not available in existing MDUs under renovation, MTS will work with the Building Owner to design a solution for the riser pathway. Several design and installation solutions are available to Building Owners that will vary depending on the age, type, size and construction material used to construct your MDU. For more information on the required agreements and installation service available to Building Owners, please contact MTS at or or visit Notes: Wood/Metal studding 14.5 spacing Height from floor 48 (min) *Standard 2 X 4 stud depth. Please note: MTS will also provide smaller in-suite distribution boxes where spacing is limited inside the mounting area or where surface mounted distribution boxes cannot be supported. Please contact MTS Consumer Public Access at / for further information. T he Building Owner is responsible for providing MTS with access to the Main Telephone Room (MTR) in the MDU, secondary communication rooms and for the installation of the in-building riser space (pathways) or conduit required to service each suite. The Building Owner is responsible for providing MTS access to all suites in the MDU. Buildings Owners are responsible for providing in-building riser wiring (such as copper or coax wiring) where Residents subscribe to services provided by other telecommunication service providers. The fibre optic material and equipment installed by MTS remains the exclusive property of MTS. 10 3

13 Figure 3 Typical In-Suite Wiring Diagram Broadband Broadband Broadband Broadband Distribution Box Electrical Panel Laundry Utility Room Broadband Notes: 1. The outlet locations shown are suggested locations. 2. A Broadband outlet is 2 Cat 5e (minimum) and 1 RG6. 11

14 MTS In-Suite MDU Guidelines Wiring Configuration A Broadband outlet location requires a minimum of 2 Cat 5e cables and 1 RG6 Coaxial cable to support TV, Internet and Voice services. All Broadband locations in exterior walls will require an electrical outlet box or MPLS/Drywall mud plate outlet and vapour barrier. All Broadband locations in interior walls will require a MPLS/ drywall mud plate or electrical box. Cables at the location must be covered with a protective material (such as plastic) at all times during construction to protect cables from any chemicals (such as paint). Paint will immediately degrade the performance of the cable sheath. For all cables installed at each broadband outlet location, an extra length of 12 inches (30 cm) of cable must be provided and stored safely in the wall cavity or electrical box. MTS will provide the required Cat 5e (minimum) and RG6 cable for the electrician/contractor for installation of the broadband outlets in each suite. A signed MTS Pre-Wire Agreement (In-Suite Pre-Wire Installation Agreement) is required between MTS and the Building Owner before any cabling starts or cabling material is shipped to the site. The cables at each outlet are terminated at the time the services are installed for each Resident. The picture below shows a finished broadband outlet after MTS home services have been installed in the Resident s suite. finished broadband outlet Please note: Additional material (such as communications cabling and outlets) required to support services available to tenants (such as enterphone systems, common area HSI or TV services, alarm services or Lobby Cam services, including Elevator Phone service, etc.) provided by the Building Owner will be determined on a case by case basis depending on what services are required. Please contact MTS Consumer Public Access Group at or

15 Glossary of Acronyms FDT FiON HSI IDB MDU MPLS MTR ONT PON UPS Fibre Distribution Terminal MTS Branded Fibre Optic Network High Speed Internet In-suite distribution box Multiple Dwelling Units Mounting plate for low voltage wire Main Telephone Room Optical Network Terminal Passive Optical Network technology Uninterrupted Power Supply Waiver of Responsibility The contents of this Guide are provided by MTS Allstream Inc. ( MTS ) for general illustration and general information purposes only. MTS does not guarantee the accuracy of the information or suggestions contained herein, and it is the Building Owner s responsibility to ensure that all electrical installations, including communications wiring, performed by third parties are done according to governing laws and regulations. It is highly recommended by MTS that such installations should only be done by a duly licensed electrician. MTS SHALL NOT BE LIABLE TO ANYONE FOR DAMAGE OR LOSS OF ANY KIND OR NATURE, INJURY OR DEATH RESULTING FROM IMPROPER ELECTRICAL INSTALLATIONS WHETHER OR NOT SUCH INSTALLATION ARISES FROM, OR IS CONNECTED TO, RELIANCE ON THIS GUIDE. ANY PRE-WIRING BY THE BUILDING OWNER, RESIDENT OR ANY OTHER PERSON PURSUANT TO THIS GUIDE IS ENTIRELY AT SUCH PERSON S OWN RISK. MTS reserves the right to refuse to connect any wiring or equipment to the MTS network that does not comply with generally recognized telecommunications standards or Manitoba Electrical Code Standards. 13

16 For more information on the required agreements and installation services or to arrange a meeting and/or site visit, please contact MTS at or

17 15

18 MTS design mark is a registered trade-mark of Manitoba Telecom Services Inc., used under license. 2467/Oct 2012

MTS FiON. for Multiple Dwelling Units (MDUs) Brownfield

MTS FiON. for Multiple Dwelling Units (MDUs) Brownfield MTS FiON for Multiple Dwelling Units (MDUs) Brownfield Table of Contents We ve Upgraded Our Network.................... 1 MTS Fibre Optics Installation Guidelines............. 2 MTS Fibre Optics In-Building

More information

Preparing a home for TransACT fibre-to-the-premise (FTTP) services

Preparing a home for TransACT fibre-to-the-premise (FTTP) services Preparing a home for TransACT fibre-to-the-premise (FTTP) services A guide for builders, telecommunications cablers and home owners transact.com.au For more information call TransACT s FTTP Sales Manager,

More information

Size Matters: When it comes to FTTH deployment in MDUs, less is more. By Linnea Wilkes, Business Development Manager Business White Paper

Size Matters: When it comes to FTTH deployment in MDUs, less is more. By Linnea Wilkes, Business Development Manager Business White Paper Size Matters: When it comes to FTTH deployment in MDUs, less is more. By Linnea Wilkes, Business Development Manager Business White Paper Table of Contents Introduction...3 The MDU Network Solution...4

More information

TracVision R6DX Installation Guide

TracVision R6DX Installation Guide TracVision R6DX Installation Guide These instructions explain how to install the TracVision R6DX satellite TV antenna system on an RV or motor coach. Complete instructions on how to use the system are

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 05 14.00 10 (April 2006) -------------------------------- Preparing Activity: USACE Superseding UFGS-27 05 14.00 10 (April 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

I1000M Rough-In Instructions

I1000M Rough-In Instructions I1000M Rough-In Instructions Thank you for purchasing an Intrasonic Technology product. Our products are built to provide you with years of high quality sound. If you need assistance with the installation

More information

fibre optic r solutions multiple dwelling Bringing units In just One Pass 3M One Pass Fibre Pathway One Floor of fibre with One Crew in One Pass

fibre optic r solutions multiple dwelling Bringing units In just One Pass 3M One Pass Fibre Pathway One Floor of fibre with One Crew in One Pass 3M Telecommunications Solutions for Networks 3M One Pass Fibre Pathway Bringing fibre optic r solutions to multiple dwelling units......in just One Pass One Floor of fibre with One Crew in One Pass 2 3M

More information

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE Prepared in cooperation and approval from BICSI Building Industry Consulting Services International and

More information

Bravo AV s Structured or Whole-House Wiring Approach

Bravo AV s Structured or Whole-House Wiring Approach Custom Audio & Video Systems: Design and Installation Bravo AV s Structured or Whole-House Wiring Approach THE QUALITY OF THE CABLE YOU USE IS CRITICALLY IMPORT TO THE PERFORMANCE OF YOUR SYSTEM Introduction

More information

Power Injector 1520 Series

Power Injector 1520 Series Power Injector 1520 Series Technical Specifications Input voltage 100 to 240 VAC Output voltage 56.0 VDC Voltage range tolerance 54 VDC to 57 VDC Maximum current 1.43 A No load current 15 ma 56VDC@0.71A

More information

TELSTRA VELOCITY HOME WIRING GUIDE BRING YOUR NEW HOME TO LIFE

TELSTRA VELOCITY HOME WIRING GUIDE BRING YOUR NEW HOME TO LIFE TELSTRA VELOCITY HOME WIRING GUIDE BRING YOUR NEW HOME TO LIFE SO WHAT IS VELOCITY HOME WIRING? Telstra Velocity home wiring lets you get your entertainment and communications from a single fibre-optic

More information

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1. PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated

More information

Telstra Velocity Home Wiring An essential guide for new home owners

Telstra Velocity Home Wiring An essential guide for new home owners Telstra Velocity Home Wiring An essential guide for new home owners Recommended Telstra Velocity Why is home wiring important to your home? When you use Telstra Velocity you won t need any antennas, modems

More information

MDU Fibre In-Building Distribution Network Design and Installation

MDU Fibre In-Building Distribution Network Design and Installation MDU Fibre In-Building Distribution Network Design and Installation Copyright Copyright 2011 Chorus New Zealand Ltd All rights reserved No part of this publication may be reproduced, stored in a retrieval

More information

Aerial Cable Installation Best Practices

Aerial Cable Installation Best Practices Aerial Cable Installation Best Practices Panduit Corp. 2007 BEST PRACTICES Table of Contents 1.0 General... 3 2.0 Introduction... 3 3.0 Precautions... 4 4.0 Pre-survey... 5 5.0 Materials and Equipment...

More information

Wiring. Requirements

Wiring. Requirements Wiring Requirements to ensure that your new home s wiring and conduit infrastructure is correctly implemented to your home stays future proof, giving you access to future services without having to surface

More information

Instrukcja montażu. FLEX LED Neon Instalacja

Instrukcja montażu. FLEX LED Neon Instalacja FLEX LED Neon Instalacja Instrukcja montażu Polned Sp. z o.o. ul. Falencka 7 PL05-090 Janki Tel. +48 22 4903434 +48 22 4903243 www.polned.pl info@polned.pl. Product Checking: 1) Unpack and carefully examine

More information

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE) PART 1: GENERAL 1.01 Telecommunications Engineer Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE) B. Registered Communications Distribution Designer

More information

ICS Digital Menu. Installation Guide Version 1.1

ICS Digital Menu. Installation Guide Version 1.1 ICS Digital Menu Installation Guide Version 1.1 Installation Overview This document was written to assist technicians and electricians in installing the ICS Digital Menu. A thorough understanding of electrical

More information

Multi-Media Installation Guide

Multi-Media Installation Guide Multi-Media Installation Guide Coaxial Page 2 Data Plug Page 7 Data Jack Page 10 Telephone Page 13 Splicing Page 15 Cable Types Cable Types Two basic types of cable are used in multimedia installations.

More information

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School BILOXI PUBLIC SCHOOL DISTRICT Biloxi Junior High School Request for Proposals E-Rate 2014-2015 - Internal Connections Submit Proposals To: Purchasing Department Attn: Traci Barnett 160 St. Peter Street

More information

STRUCTURED CABLE SYSTEM (SCS)

STRUCTURED CABLE SYSTEM (SCS) PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated

More information

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM Content 1. General 5 2. The products of NC-1000 system 6 3. Mounting of the frame 8 4. Earthing of the frame 8 NC-1000 FIBRE OPTIC

More information

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM COURSE ORIGINATOR Cabling and Conduit K Norgate DATE 23rd August 2013 Amendment 1 5th October 2013 Technical changes - Issued Amendment 2 6th October

More information

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16) Satellite multiswitch Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16) EMP-CENTAURI is a registered trademark Dear Customer, Thank you for buying the EMP-Centauri

More information

IndyGo Facility Upgrades Project 35671EE

IndyGo Facility Upgrades Project 35671EE SECTION 260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Identification for raceways. 2. Identification of power and control cables. 3. Identification for

More information

Extender for HDMI over one CAT5

Extender for HDMI over one CAT5 1080P Extender for HDMI over one CAT5 GTV-HDBT-CAT5 User Manual gefentv.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours:

More information

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12) MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL OPTEVA 868 THROUGH THE WALL ATM WITH mm ( 2") CEN-L SAFE L00 CALL -800-999-600 22 (9 6") REQUIRED FOR WALLS EXCEEDING 0mm (2") CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND

More information

4 Wiring Brochure Wiring and installation of specific control

4 Wiring Brochure Wiring and installation of specific control - Wiring Brochure tekmarnet 4 User Switch 480 W 480 09/09 1 Information Brochure Choose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in

More information

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV REV. 1.0 Fully ly Automaticti Motorised Satellite t TV System User s manual Customer Help Line: 1300 139 255 Support Email: support@satkingpromax.com.au Website: www.satkingpromax.com.au www.satkingpromax.com.au

More information

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS Power and Control 26 1999 November/December IAEI NEWS T YPE BY RAVI GANATR This article discusses how the requirements in both the installation code and the product standard are utilized to manufacture

More information

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012 STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE Publication S-115-730 First Edition - June 2012 Published By Insulated Cable Engineers Association, Inc. Post Office Box 1568 Carrollton, Ga 30112,

More information

3M One Pass Mini Fiber Pathway

3M One Pass Mini Fiber Pathway 3M One Pass Mini Fiber Pathway Executive Questions What is the 3M One Pass Mini Fiber Pathway? The 3M One Pass Mini Fiber Pathway is a flexible, single-fiber, surface-mount cable pathway and drop cable

More information

VITALink Taped Splice Straight Through Crimp

VITALink Taped Splice Straight Through Crimp A Marmon Wire & Cable Berkshire Hathaway Company VITALink Taped Splice Straight Through Crimp 2 Hour Fire-Rated Splice VITALink MC Cables, UL FHIT 120 Installation Instructions Description The VITALink

More information

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s dv/dt filter plus Voltage Peak Limiter Safety information 1 General 2 SINAMICS SINAMICS G130 Operating Instructions Mechanical installation 3 Electrical

More information

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16)

Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-CP-12 (13/12) P.160-CP-16 (13/16) Satellite multiswitch Instructions for Use P.160-AP-8 (13/8) P.160-CP-8 (13/8) P.160-AP-12 (13/12) P.160-CP-12 (13/12) P.160-AP-16 (13/16) P.160-CP-16 (13/16) EMP-CENTAURI is a registered trademark Dear

More information

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12") MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL

R OPTEVA 868 THROUGH THE WALL ATM. 305mm (12) MAXIMUM WALL THICKNESS IN AREA OF UNIT OUTLINE OF OPTIONAL ILLUMINATED SIGNAGE PANEL OPTEVA 868 THROUGH THE WALL ATM WITH 40mm ( 6") CEN III AND CEN IV SAFE L0 CALL -800--600 0 (6") REQUIRED FOR WALLS EXCEEDING 0mm (2") CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS

More information

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Traditional RF Splitter/Combiner and Directional Coupler User Manual Traditional RF Splitter/Combiner and Directional Coupler User Manual Content Page INTRODUCTION... 1 Revision History... 2 Trademark Information... 2 Admonishments... 2 General Safety Precaution... 2 1

More information

White Paper. Next Generation of Fiber Optic Loose Tube Cable. ABSTRACT INTRODUCTION. Stephen Martin, Product Line Manager, RCDD

White Paper. Next Generation of Fiber Optic Loose Tube Cable.   ABSTRACT INTRODUCTION. Stephen Martin, Product Line Manager, RCDD Next Generation of Fiber Optic Loose Tube Cable Stephen Martin, Product Line Manager, RCDD ABSTRACT The evolutionary path of outside plant (OSP) fiber optic loose tube cables with the standard 600-lb load

More information

Cabling of New Homes for Telstra Velocity

Cabling of New Homes for Telstra Velocity Network Engineering Access Infrastructure Guideline 013234 Cabling of New Homes for Telstra Velocity Information for Builders and Telecommunications Cablers Implementation Approval: Craig Hedges Technology

More information

Effective earthing of screened cables

Effective earthing of screened cables NOVEMBER 2006 Effective earthing of screened cables All metallic containment items, other extraneous metalwork and the screens of telecommunications cables in an information technology environment must

More information

Register your product and get support at SDV5122/27. EN User manual

Register your product and get support at   SDV5122/27. EN User manual Register your product and get support at www.philips.com/welcome SDV5122/27 User manual Contents 1 Important 4 Safety 4 Notice for USA 5 Notice for Canada 5 Recycling 6 English 2 Your SDV5122 7 Overview

More information

Sample Test Project. District / Zonal Skill Competitions. Skill- Electrical Installation. Category: Construction and Building Technology

Sample Test Project. District / Zonal Skill Competitions. Skill- Electrical Installation. Category: Construction and Building Technology Sample Test Project District / Zonal Skill Competitions Skill- Electrical Installation Category: Construction and Building Technology Version 1 Dec 2017 Skill- Electrical Installation 1 Table of Contents

More information

3M Fiber Optic Closure System LL

3M Fiber Optic Closure System LL 3M Fiber Optic Closure System LL 3M Fiber Optic Closure System The 3M Fiber Optic Closure System LL provides a protective yet accessible environment for housing single or mass fusion fiber splices. The

More information

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION COMMUNICATIONS HORIZONTAL CABLING (NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) PART 1 - GENERAL 1.1 SECTION

More information

Cambria County Association for the Blind and Handicapped 175 Industrial Park Road Ebensburg, PA Prepared for: Prepared by:

Cambria County Association for the Blind and Handicapped 175 Industrial Park Road Ebensburg, PA Prepared for: Prepared by: Cable Management in Solar PV Arrays: A Review of Requirements in the National Electrical Code and how CAB Cable Rings and Saddles Meet These Requirements Prepared for: Cambria County Association for the

More information

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz ASSEMBLY AND INSTALLATION A449-6S 70 CENTIMETER FM YAGI ANTENNA 440-450 MHz COMMUNICATIONS ANTENNAS 951425 (7/93) WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT IN

More information

3 Locating and Marking Products DOCUMENT OBSOLETE

3 Locating and Marking Products DOCUMENT OBSOLETE 3 Locating and Marking Products This was Wall Street, 1921 2 Imagine what it s like down there today. 3 Spotting the target with Dynatel Cable/Fault Locators. The opening photos in this brochure show the

More information

Traditional RF Splitter/Combiner and Directional Coupler User Manual

Traditional RF Splitter/Combiner and Directional Coupler User Manual Traditional RF Splitter/Combiner and Directional Coupler User Manual Content Page INTRODUCTION... 1 Revision History... 2 Trademark Information... 2 Admonishments... 2 General Safety Precaution... 2 1

More information

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range Installation Manual Table of Contents Basic Operation...2 CR-R880-BL Block Diagram...2 Technical Specifications...3 Features...4

More information

Copyright Black Box Corporation. All rights reserved.

Copyright Black Box Corporation. All rights reserved. Copyright 2003. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 SOHO 6-Port CAT5e 568B Data Module SEPTEMBER 2003 JPM1101A CUSTOMER SUPPORT

More information

REDFISH TECHNOLOGIES

REDFISH TECHNOLOGIES REDFISH TECHNOLOGIES CLIENT CCTV PRELIMINARY DESIGN REQUIREMENTS Client Name: Client Address: Client Site: Date Important The more detailed information that can be provided in this form, the more accurate

More information

Bookcheck Model 966. Site Planning Guide

Bookcheck Model 966. Site Planning Guide Bookcheck Model 966 Site Planning Guide 3M Library Systems 3M Center, Building 225-4N-14 St. Paul, Minnesota 55144-1000 Copyright 2002, 3M IPC. All rights reserved. www.3m.com/library 060-A 78-8123-7852-5,

More information

Cyclo Series. user manual. MartinArchitectural

Cyclo Series. user manual. MartinArchitectural Cyclo Series user manual MartinArchitectural Measurements are in millimeters 63 Cyclo 02 88 Cyclo 03 1000 81 1190 88 Cyclo 04 98 88 2002 Martin Professional A/S, Denmark. All rights reserved. No part of

More information

DISTRIBUTION AMPLIFIER

DISTRIBUTION AMPLIFIER MANUAL PART NUMBER: 400-0045-005 DA1907SX 1-IN, 2-OUT VGA/SVGA/XGA/UXGA DISTRIBUTION AMPLIFIER USER S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2 GENERAL...2 GUIDELINES FOR RACK-MOUNTING...2

More information

16 Amp Electronic 24 Hour/7 Day Time Controller

16 Amp Electronic 24 Hour/7 Day Time Controller 16 Amp Electronic 24 Hour/7 Day Time Controller Model: ELU56 Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference

More information

OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION

OPTEVA 828 LOBBY ATM FRONT LOAD PLAN VIEW FRONT ELEVATION SIDE ELEVATION L0 CALL -800--600 OPTEVA 88 LOBBY ATM FRONT LOAD WITH 0mm ( 6") CEN III AND CEN IV SAFE CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE PLANNING AND

More information

APPLICATION OF POWER SWITCHING FOR ALTERNATIVE LAND CABLE PROTECTION BETWEEN CABLE LANDING STATION AND BEACH MAN HOLE IN SUBMARINE NETWORKS

APPLICATION OF POWER SWITCHING FOR ALTERNATIVE LAND CABLE PROTECTION BETWEEN CABLE LANDING STATION AND BEACH MAN HOLE IN SUBMARINE NETWORKS APPLICATION OF POWER SWITCHING FOR ALTERNATIVE LAND PROTECTION BETWEEN LANDING STATION AND BEACH MAN HOLE IN SUBMARINE NETWORKS Liyuan Shi (Huawei Marine Networks) Email: Huawei

More information

3M Distribution Box (DDB)

3M Distribution Box (DDB) 3M Distribution Box (DDB) Merged Copper and Fiber Pole/Post Mount Enclosure Installation Instructions November 2015 78-0015-2736-1-A 2 November 2015 78-0015-2736-1-A Contents 1.0 General 2.0 Enclosure

More information

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box. FTTH & FITH Discreet optical fiber solutions from the network connection point to the set-top box www.omelcom.com FIBER: THE FUTURE IS HERE The past several years have seen major progress in the penetration

More information

AMERICAN NATIONAL STANDARD

AMERICAN NATIONAL STANDARD Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 129 2017 Drop Passives: Bonding Blocks (Without Surge Protection) NOTICE The Society of Cable Telecommunications Engineers (SCTE) Standards

More information

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE Conduit Installation A conduit cable installation involves placement of one or more optical cables inside a preinstalled

More information

LED MODULES READYLINE DL

LED MODULES READYLINE DL LED MODULES READYLINE DL BUILT-IN MODULE LED-MODULE READYLINE DOWNLIGHT DL WU-M-538 / WU-M-539 / WU-M-540 Typical Applications Downlights Replacement for CFL DIRECT MAINS CONNECTION REDUCED FLICKER HIGH

More information

Register your product and get support at www.philips.com/welcome SDV8625T/27 User manual Contents 1 Important 4 Safety 4 For indoor use 4 For outdoor use 4 Notice for USA 4 Notice for Canada 5 Recycling

More information

Operation Manual VMS 3.0 Video System

Operation Manual VMS 3.0 Video System Operation Manual VMS 3.0 Video System for the AlterG Anti-Gravity Treadmill 1 This manual covers operation procedures for the following AlterG products: AlterG Video System model VMS 3.0 NOTE: The following

More information

Cisco Aironet 1520 Series Outdoor Mesh Access Point Power Injector Installation Instructions

Cisco Aironet 1520 Series Outdoor Mesh Access Point Power Injector Installation Instructions Cisco Aironet 1520 Series Outdoor Mesh Access Point Power Injector Installation Instructions This document describes the Cisco Aironet 1520 Series Outdoor Mesh Access Point Power Injector (hereafter referred

More information

User Manual. HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D

User Manual. HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D User Manual HDTV Cat 5 Extender Video and Audio Over One Cat 5 Cable Model SCP-11 and SCP-11D Model 1180T Transmitter Model 1180R Receiver Model 1180TD Transmitter Model 1180RD Receiver WARNINGS Read these

More information

CONSTRUCTION SPECIFICATION FOR TRAFFIC SIGNAL EQUIPMENT

CONSTRUCTION SPECIFICATION FOR TRAFFIC SIGNAL EQUIPMENT ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS.PROV 620 APRIL 2017 CONSTRUCTION SPECIFICATION FOR TRAFFIC SIGNAL EQUIPMENT TABLE OF CONTENTS 620.01 SCOPE 620.02 REFERENCES 620.03 DEFINITIONS 620.04

More information

WORLD CLASS MEDIA PRODUCTION/RECORDING STUDIO FOR SALE STUDIOS OF CONCENTRIX MUSIC AND SOUND DESIGN, INC.

WORLD CLASS MEDIA PRODUCTION/RECORDING STUDIO FOR SALE STUDIOS OF CONCENTRIX MUSIC AND SOUND DESIGN, INC. WORLD CLASS MEDIA PRODUCTION/RECORDING STUDIO FOR SALE SALE PRICE: $775,000 BUILDING SIZE: 4,000 SF YEAR BUILT: 2009 ZONING: I-1 PROPERTY OVERVIEW Expertly designed media production/recording studio located

More information

Electric Motorized Projection Screen Spectrum Tab-Tension Series User s Guide

Electric Motorized Projection Screen Spectrum Tab-Tension Series User s Guide Electric Motorized Projection Screen Spectrum Tab-Tension Series User s Guide Important Safety Precautions Make sure to read this user s guide and follow the procedures below prior to screen operation.

More information

Buildings. Barry Walton Senior Advisor - Access FTTP

Buildings. Barry Walton Senior Advisor - Access FTTP FTTP & Mutli - Tenant Buildings Barry Walton Senior Advisor - Access FTTP Objectives today Bandwidth GPON Architecture FTTP access design Brownfield Greenfield Brownfield challenges hll Safety Where are

More information

Section Communications Optical Fiber Backbone Cabling

Section Communications Optical Fiber Backbone Cabling Part 1 1.1 Related Documents 1.1.1 Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specifications Sections apply to this Section. 1.2 Related

More information

General Questions. Q: What s the big deal about fiber? Why is it better than what I have today? Q: How is the fiber going to be installed to my home?

General Questions. Q: What s the big deal about fiber? Why is it better than what I have today? Q: How is the fiber going to be installed to my home? General Questions Frequently Asked Questions Q: What s the big deal about fiber? Why is it better than what I have today? A: Let s start by defining what Hotwire means when we say fiber verses when another

More information

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98) Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98) 1. Splicing specifications are provided by Mediacom, but due to resplice conditions, many locations become

More information

DISH Pro Hybrid 42 Switch Installation Guide

DISH Pro Hybrid 42 Switch Installation Guide DISH Pro Hybrid 42 Switch Installation Guide VideoPath DISH PRO HYBRID SWITCH MODEL DPH42 209929 MMTTVV-FMYYXXXXX Made in XXX RECEIVER SATELLITE IN Power Inserter 12.5-29V 1825mA Safety Information Warning

More information

Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages)

Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages) Lynx Broadband Installation Manual for Residential Packages with a 35 db Amp Quick Start Guide (first 3 pages) 1. Be sure that your kit includes all the parts shown in the Check the Equipment section in

More information

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes. SECTION 33 71 49.23 MEDIUM VOLTAGE CABLE INSTALLATION PART 1 GENERAL 1.1 SCOPE A. Work included in this Section: Medium Voltage Cable (4 kv and 12 kv) Installation and Termination. Removal and return of

More information

CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories

CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories Evolution Cable Management Page 5-3 Velocity Cable Management Page 5-8 Velocity Standard Pack Page 5-12 Vertical Cable Management Page 5-13 Global

More information

Georgia World Congress Center 285 Andrew Young International Blvd Atlanta, GA Engineering Dept: Fax:

Georgia World Congress Center 285 Andrew Young International Blvd Atlanta, GA Engineering Dept: Fax: 285 Andrew Young International Blvd Engineering Dept: 404-223-4800 Fax: 404-223-4813 Event dates: September 17-19, 2019 Standard Rates will be applied to all orders received via fax, mail, or emails to

More information

DS1 Cross-Aisle Panel

DS1 Cross-Aisle Panel DS1 Cross-Aisle Panel Model 005-0005-0100 Installation Guide 1.1 Overview 1.1.1 Inspection Compare the contents of the DS1 Cross-Aisle Panel shipping container with the packing list. Call Telect if anything

More information

Laying of cables and lines in electrical installations and data networks

Laying of cables and lines in electrical installations and data networks Technical bulletin Laying of cables and lines in electrical installations and data networks Date: 08/2006 This technical bulletin provides you with information on specific technical subjects. It is based

More information

Integrated Systems Proposal

Integrated Systems Proposal Integrated Systems Proposal GALLERIA MALL WEST DRW Construction & Development 511 Progress Parkway Chesterfield, MO 63012 314-525-1147 Prepared by: Elite AV Systems Tom Donovan t.donovan@eliteavsystems.com

More information

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130 Operating Manual (Edition 04/2004) sinamics Line Reactors SINAMICS G130 Contents 1. Safety Information 2 2. General 5 3. Mechanical Installation 6 4. Electrical Installation 8 5. Technical Specifications

More information

Multi-Channel Passive Transceiver Hubs Installation Sheet

Multi-Channel Passive Transceiver Hubs Installation Sheet GE Security Multi-Channel Passive Transceiver Hubs Installation Sheet Introduction GE Security Multi-Channel Passive Transceiver Hubs transmit or receive baseband video signals over unshielded twisted

More information

Starling Tab-Tension 2 Series

Starling Tab-Tension 2 Series Electric Wall/Ceiling Projection Screen Starling Tab-Tension 2 Series For: Spectra White FG and CineGrey 5D User s Guide Important Safety & Warning Precautions Make sure to read this user s guide and follow

More information

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax

More information

Monochrome Video Monitors

Monochrome Video Monitors Instructions for Use Monochrome Video Monitors En F D E NL I LTC 2009 LTC 2012 LTC 2017 Philips Communication & Security Systems GB F D E NL I Instructions for Use...1.1 Mode d emploi...2.1 Bedienungsanleitung...3.1

More information

IPSTB1200 /IPC3200 Media Client User guide

IPSTB1200 /IPC3200 Media Client User guide IPSTB1200 /IPC3200 Media Client User guide Safety/Compliance Important Safety Instructions Please carefully read these safety and compliance instructions and this entire user guide. Follow all instructions

More information

Primex Wireless, Inc. July, Wells Street Lake Geneva, WI

Primex Wireless, Inc. July, Wells Street Lake Geneva, WI Division 0 0 0 0 Primex Wireless, Inc. July, 00 Wells Street Lake Geneva, WI 00--0 www.primexwireless.com Product Guide Specification Specifier Note: This product specification is written according to

More information

LCD VALUE SERIES (32 inches)

LCD VALUE SERIES (32 inches) LCD VALUE SERIES (32 inches) http://www.orionimages.com All contents of this document may change without prior notice, and actual product appearance may differ from that depicted herein 1. SAFETY INSTRUCTION

More information

A CENTIMETER FM YAGI ANTENNA MHz

A CENTIMETER FM YAGI ANTENNA MHz ASSEMBLY AND INSTALLATION A449-70 CENTIMETER FM YAGI ANTENNA 440-450 MHz COMMUNICATIONS ANTENNAS 951424 (10/91) WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT IN DEATH

More information

SC-C1M SiriusConnect TM Vehicle Tuner

SC-C1M SiriusConnect TM Vehicle Tuner SC-C1M SiriusConnect TM Vehicle Tuner For Special Market Applications Installation Guide Congratulations on the Purchase of your new SIRIUS SC-C1 SiriusConnect TM Vehicle Tuner. The SC-C1M is packaged

More information

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING SUMITOMO PRODUCT SPECIFICATION FutureFLEX TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100,

More information

UFB Ready Property Guidelines

UFB Ready Property Guidelines UFB Ready Property Guidelines Volume 3 - MDU Fibre In-Building Distribution Network Design and Installation Publication Date: 22 March, 2017 Document Number: ND0629 v2.0 (Volume 3) Document Control Copyright

More information

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 27 Communication 0553 Identification for Communications Systems

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 27 Communication 0553 Identification for Communications Systems 1 General 1.1 Scope of work 1.1.1 The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable to the completion of

More information

User Guide. HDMI Fiber Optic Extender. DVI-7350a

User Guide. HDMI Fiber Optic Extender. DVI-7350a User Guide HDMI Fiber Optic Extender DVI-7350a Table of Contents Section Page Product Safety.................................... 1 1.0 Introduction...2 2.0 Specifications...3 3.0 Package Contents...3 4.0

More information

Atlona HDBaseT-Lite Transmitter over Single CAT5e/6/7

Atlona HDBaseT-Lite Transmitter over Single CAT5e/6/7 Atlona HDBaseT-Lite Transmitter over Single CAT5e/6/7 AT-HDTX User Manual Table of Contents 1. Introduction... 3 2. Package Contents... 3 3. Features... 3 4. Specifications... 3 5. Panel Descriptions a.

More information

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT COPYRIGHT Gigabit Multi-mode SX to Single Mode LX Converter User s Manual NGF-728 Series All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Installation. SAPTF33xx-1xx in the Network. Standard Configuration SAPTF33xx-1xx in the Network Standard Configuration One Unit A device (SAPTF33xx-100) and one device () are required for the standard configuration. The Unit A device is connected to the while the device

More information

Fiber drop cable solutions. Flexible solutions for the evolving networks of tomorrow

Fiber drop cable solutions. Flexible solutions for the evolving networks of tomorrow iber drop cable solutions lexible solutions for the evolving networks of tomorrow Welcome to the Broadband Age, where your network must continually evolve to keep pace with your customers At CommScope,

More information