1 ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION 1.0 General 1.1 The work covered by this section consists of providing all labor, equipment, insurance, accessories, tools, transportation, supplies, materials, supervision, data compilation and diagnosis, meetings and technical competence to perform all operations required to conduct a closed-circuit television (CCTV) inspection of designated pipeline segments and manholes. 1.2 The Contractor shall utilize Pipeline Assessment and Certification Program (PACP) certified inspectors for this contract at all times and PACP Version 7 coding methods shall be employed for all CCTV inspections conducted under this contract. Evidence of PACP certification of the Operator shall be provided to the NBC prior to the commencement of any work. 1.3 The Contractor shall be responsible for removing his equipment from the sewers and for all associated sewer and restoration repairs necessary as a result of his work. 1.4 The Contractor will be responsible for obtaining pertinent information to safely and effectively perform all work. 1.5 The Contractor s field technicians must maintain current certifications for Confined Space Entry as defined in OSHA regulations, 29CFR1910 and all amendments. The Contractor must have and utilize all necessary safety equipment to enter a Permit Required Confined Space and maintain it in good working order. The contractor must produce OSHA 10 hour and or 30 hour cards before any work commences. 1.6 Definitions: Pipe Inspection: Color television inspection by obtaining a closed circuit television camera view into a sewer line for the purpose of visual inspection of the interior portion of the sewer line structures using PACP 7 coding methods as detailed in section 1.2 in this specification. A permanent color recording of all interceptor inspection s is produced by the contractor and submitted to the NBC Inspection Operator: PACP-certified inspector trained in operating inspection equipment Pipe Segment: Defined as length of pipe measured from center of upstream manhole or node point to center of downstream manhole or node point. 1.7 The intent of the pipe inspection services is to accomplish two basic functions: (1) to provide an accurate understanding of the existing pipe and its condition; and (2) to identify and asses the condition of all connections to the sewer. 2.0 Products 2.1 Maps and Details The NBC will provide the contractor with an Excel spreadsheet that will include pertinent information on the various pipe segments and manholes to be included in the contract The NBC will make available GIS plans showing the entire run of sewer to be 3/26/2018 Page CCTV-1
2 inspected, including aerial photographs indicating locations of various pipe segments and manholes to be included in the contract The information provided herein is the best record that the NBC has on the sewer. Actual conditions may vary from what is indicated on the information provided. 2.2 CCTV Equipment The Contractor shall select and use a CCTV system that is a self-contained system complete with closed circuit television camera, monitor, and computer system with video capture card or specialized video recording equipment capable of pausing and resuming live recordings, capable of entering a manhole cover with a minimum opening of 18 diameter clearance, and all necessary equipment for the successful completion of television inspection. The equipment shall be capable of performing inspections from manholes in various field conditions. The Contractor shall have alternative capabilities to perform inspections as specified in areas where vehicle access to manholes is limited. The contractor shall have equipment capable of viewing all pipeline connections to NBC structures in order to assess the condition at the point where the connecting pipe ties into the NBC mainline and to assess whether or not the connection to the pipe is active or sealed in the immediate area of NBC property. The inspection will be limited to the extent of available camera lighting and/or bends in the connection; no device, (such as a lateral launcher), shall enter any service connections. The purpose of this observation is to assess the condition at the point of connection to the NBC pipe and attempt to determine its current state and condition; (abandoned/active; poor/good) Contractor shall locate pre-designated manholes with a utility locator comprised of a receiver and transmitter per contract specifications. The transmitter shall be capable of transmitting 16Hz, 512Hz, and 8KHz and shall be firmly secured to the CCTV Transporter/Camera unit. The receiver must be capable of locating the transmitter in pipelines comprised of brick, clay, iron, plastic, and asbestos pipe materials and at depths up to 80 feet. The receiver must also be capable of tracing pipelines and depth determination. 2.3 Pipe Inspection Camera The Contractor shall produce a video using a pan-and-tilt, radial viewing pipe inspection camera that pans 275 degrees and rotates 360 degrees. The camera used for the inspection shall be specifically designed and constructed for such inspection. The camera must be solid-state color and have remote control of the 360-degree rotational lens. Cameras incorporating mirrors for viewing sides or cameras using exposed rotating heads are not acceptable. The camera shall be operative in 100% humidity conditions. Lighting for the camera shall be suitable to allow a clear picture of the entire periphery of the pipe. The video camera shall be capable of showing on the video the City name, Project name, Contractor name, date, pipe size and material, line identification number (NBC GIS upstream and downstream manhole identification numbers). The inspection shall show this information in the beginning of the inspection but not proceed with this information displayed on the screen throughout the inspection. The camera, monitor and other components of the video system shall be capable of producing a minimum 460 line resolution video 3/26/2018 Page CCTV-2
3 picture. Picture quality and definition shall be to the satisfaction of the NBC and if unsatisfactory, equipment shall be removed and replaced with adequate equipment. No payment will be made for an unsatisfactory inspection All CCTV inspections shall require a crawler transporter; floating for video inspections will NOT be allowed unless the pipe segment has been pre-approved by the NBC. 2.4 Deliverables The contractor shall provide all inspection data and files on a portable external hard drive and shall become the property of the NBC once submitted The external hard drive shall contain all video files located in a separate file folder titled Pipe Inspection Videos in standard mpg video file format burned with a current version of Microsoft Windows Media Player and individual, (not combined), PDF files of each inspection report located in a separate file folder titled Pipe Inspection Reports. The report file shall note all required header information and observations/defects per NASSCO s PACP guidelines. Individual files shall be named with its NBC GIS Unit ID and date of inspection as indicated in section A label permanently affixed to the external hard drive is required as noted in Section The external hard drive shall contain the most current NASSCO version of a PACP database which should be exported from the native software product All mpg video files and individual report PDF s contained on the hard drive shall be named as follows: upstream manhole ID-downstream manhole ID-Date- TimeStamp: (i.e.m m mmddyyyy-hhmmss.mpg:m M MMDDYYYY-HHMMSS.pdf ) Defect classifications and descriptions shall be PACP compliant as detailed in section 1.2 in this specification. 2.5 Viewing Software Software shall be PACP 7 Certified. 3.0 Execution 3.1 CCTV Inspection of Sewer Lines Prepare area of pipe inspection to provide safe conditions for vehicle and pedestrian traffic throughout the inspection procedure Perform gas monitoring within manhole structure at various levels prior to opening the manhole cover and after the cover is opened to ensure safe atmospheric conditions. Monitored gasses must include but not limited to: Methane, Hydrogen Sulfide, Oxygen, Carbon Dioxide, and Carbon Monoxide Record television pipe inspections at the conclusion of any cleaning work as 3/26/2018 Page CCTV-3
4 required in Attachment 3: Specifications for Sewer Cleaning At the discretion of the NBC or if the operator questions the accuracy of the supplied data, the contractor shall field verify pipeline information Documentation of the pipe data shall be presented as detailed in section If, during the inspection operation, an inspection cannot be completed due to pipe blockages/obstructions/surcharging, the Contractor shall attempt to complete the inspection from the opposite manhole If conflicts between NBC s records and actual field conditions are encountered in the field, additional line segments with temporary unit identification numbers may need to be input to simulate actual field conditions. In this event, additional CCTV inspections may be required for the area in question. Any additional payments pertaining to this work will be at the agreed upon contract unit price per foot of CCTV work. The contractor shall notify and obtain approval by an authorized NBC employee prior to performing any work beyond the scope of the original contract The Contractor shall provide lighting during the CCTV inspection that fully illuminates, but does not overly illuminate the entire pipe The operator shall insure the camera and video display correctly reflect the true colors within the pipe and on the video display Flow Control: No flow control devices will be permitted. Flow level may be allowed up 25% during inspections. If inspections cannot be completed with appropriate flow levels, the inspection may be abandoned, as dictated in NASSCO s PACP guidelines. In all cases of flow levels interrupting the camera view, inspections must be attempted from the upstream and downstream access points. NBC shall be provided with the video footage of the flow conditions during these inspection attempts. This item shall be paid based upon actual footage inspected. CCTV inspections shall be made during normal business hours. Exceptions may be granted to accommodate CCTV inspections with flow level disturbances. The Contractor may request to inspect pipe sections during the low flow period or during off-hours if flows conditions exceed allowable limits. No payment adjustments will be made for any work done off-hours. Inspections that fall outside normal business hours must be pre-approved at least three business days prior to the intended work. 3.2 Documentation of Inspection The Contractor must use PACP Certified software package for documenting the inspection Data Archive: All inspection records shall be retained by the Contractor for a minimum period of 5 years and will be made accessible by the NBC with no additional charge during this time period. 3/26/2018 Page CCTV-4
5 3.2.3 Digital Photographs: All defects shall be documented as digital picture files Video Recordings: The purpose of video recording shall be to supply a visual and audio record of the inspections. Video recordings shall include an audio track recorded by the inspector during the actual inspection work describing the parameters of the line being inspected (i.e. Manhole ID to Manhole ID, date and time, location, depth, diameter, material), as well as describing connections (service, building, storm, etc.), defects and unusual conditions and other discernible features. Video recording playback shall be at the same speed that it was recorded. Slow motion or stop-motion playback features may be supplied at the option of the Contractor. The use of the zoom feature during recordings shall be utilized only when necessary so as to properly reflect the actual position of the camera during inspections. Once recorded, the videos shall become the property of the NBC. No less than 90% of the portable hard drive capacity shall be filled. The inspection information shall note all distinguishable defects and all other pertinent information; (infiltration/inflow quantification, roots, footages, jpegs, subsystem and manhole segment, etc.) Upon request from the NBC, interim data on a portable hard disk drive shall be submitted throughout the course of the contract for the purpose of quality control viewing and acceptance Permanent hard drive labels are required as detailed below. Contract Title: Contract No.: Company Info: Hard Drive No.: Date: 3.3 Digital Format Video Recordings The Contractor shall capture the inspections in digital color format from the live video source on an external hard drive to the following requirements: i. MPEG format. ii. Picture Size: NTSC 352 x frames per second iii. Data/Bit Rate: 1.5 M-bits/sec Obtain digital video inspections from first generation recordings using video capture equipment capable of capture with no frame loss. 3/26/2018 Page CCTV-5
6 3.4 Coordination with Others: The Contractor shall be responsible for coordinating any efforts with local authorities, as necessary. The Contractor shall be responsible for all payments imposed by local authorities for any services provided, except as indicated in the Attachment 5: Specification for Traffic Control Where applicable, the Contractor shall be responsible for coordinating work located within any private, local, state or federal property regarding access and/or right-of-ways necessary to complete the work. For any work located within a railroad authority jurisdiction that requires payment for such work, the NBC will pay the authority directly for said services. The Contractor is responsible for the coordination, notification, scheduling and cancelling of any services required to complete the work. The Contractor shall reimburse the NBC for any costs incurred due to failure to comply with the railroad authorities requirements. Payment of any services required and approved from the railroad authority will be paid directly to the railroad authority by the NBC. 4.0 Measurement 4.1 Basis of Payment: Pipe segments for CCTV Inspection shall be measured from center of manhole to center of manhole. END OF SECTION 3/26/2018 Page CCTV-6
Appendix 1 CLOSED-CIRCUIT TELEVISION INSPECTION
Appendix 1 CLOSED-CIRCUIT TELEVISION INSPECTION GENERAL 1.1 SUMMARY A. The Vendor shall f urnish all labor, materials, equipment, transportation, and incidentals as shown, specified or require d for closed-circuit
More informationCONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION (CCTV) INSPECTION OF PIPELINES
ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.MUNI 409 NOVEMBER 2017 CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION (CCTV) INSPECTION OF PIPELINES TABLE OF CONTENTS 409.01 SCOPE 409.02 REFERENCES
More informationAMENDMENTS TO OPSS 409 (APR 99) CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES
Works and Emergency Services CITY OF TORONTO WATER AND WASTEWATER SERVICES STANDARD CONSTRUCTION SPECIFICATIONS TS 409 November 2010 AMENDMENTS TO OPSS 409 (APR 99) CONSTRUCTION SPECIFICATION FOR CLOSED
More informationCONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION (CCTV) INSPECTION OF PIPELINES
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 409 NOVEMBER 2013 CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION (CCTV) INSPECTION OF PIPELINES TABLE OF CONTENTS 409.01 SCOPE 409.02 REFERENCES
More informationCONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 409 APRIL 1999 CONSTRUCTION SPECIFICATION FOR CLOSED CIRCUIT TELEVISION INSPECTION OF PIPELINES TABLE OF CONTENTS 409.01 SCOPE 409.02 REFERENCES 409.03
More informationCONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION INSPECTION OF PIPELINES
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 409 NOVEMBER 2009 CONSTRUCTION SPECIFICATION FOR CLOSED-CIRCUIT TELEVISION INSPECTION OF PIPELINES TABLE OF CONTENTS 409.01 SCOPE 409.02 REFERENCES
More informationTHE CITY OF WATERLOO SPECIFICATION FOR THE INVESTIGATION OF SANITARY SEWER LATERALS USING CLOSED CIRCUIT TELEVISION CAMERA (CCTV) 2016
THE CITY OF WATERLOO SPECIFICATION FOR THE INVESTIGATION OF SANITARY SEWER LATERALS USING CLOSED CIRCUIT TELEVISION CAMERA (CCTV) 2016 TABLE OF CONTENT 1.0 SCOPE OF WORK... 3 1.1 GENERAL... 3 1.2 OBJECTIVES:...
More informationSpecifications For CCTV Inspection Of Sanitary & Storm Sewers (Revised Aug. 2018)
Specifications For CCTV Inspection Of Sanitary & Storm Sewers (Revised Aug. 2018) 1.0 INTENT It is the intent of this Specification to describe the services to be provided. 1) The Closed-Circuit Television
More informationDISCLAIMER. This document is current at the date of downloading. Hunter Water may update this document at any time.
DISCLAIMER This Standard Technical Specification was developed by Hunter Water to be used for construction or maintenance of water and/or sewerage works that are to become the property of Hunter Water.
More informationSECTION 25 CLOSED CIRCUIT TELEVISION INSPECTION OF SEWER LINES
2017 - SECTION 25 CLOSED CIRCUIT TELEVISION INSPECTION OF SEWER LINES 25.1 GENERAL This section of the specifications shall form a part of the contract documents and should be read in conjunction with
More informationTable of Contents. Section E: Inspection and Acceptance
Table of Contents Section E: Inspection and Acceptance Section Page E.1 52.252-2 Clauses Incorporated by reference (Feb 1998) 1 E.2 Cutover and Acceptance Testing of Services and Systems 1 E.2.1 Cutover
More informationSECTION 3 SPECIFICATIONS FOR TELEVISION INSPECTION OF SANITARY AND STORM SEWER 0053
SECTION 3 SPECIFICATIONS FOR TELEVISION INSPECTION OF SANITARY AND STORM SEWER 0053 3.1 INTENT It is the intent of this Specification to describe the services to be provided. 1) The Closed Circuit Television
More informationSECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.
SECTION 33 71 49.23 MEDIUM VOLTAGE CABLE INSTALLATION PART 1 GENERAL 1.1 SCOPE A. Work included in this Section: Medium Voltage Cable (4 kv and 12 kv) Installation and Termination. Removal and return of
More informationThe University of Texas at Austin September 30, 2011
SECTION 27 08 20 COPPER TESTING PART 1 - GENERAL 1.1 SUMMARY A. Test measurements shall be taken for all balanced-twisted pair cabling, including horizontal and backbone copper cables and wall-to-rack
More information1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment
1993 Specifications CSJ 0922-33-042, etc. SPECIAL SPECIFICATION ITEM 8549 CCTV Central Equipment 1. Description. This Item shall govern for the furnishing and installation of closed circuit television
More informationVERIZON MARYLAND INC.
VZ MD 271 Attachment 207 VERIZON MARYLAND INC. Methods and Procedures for Access To Poles, Ducts, Conduits and Rights-of-Way for Telecommunications Providers VERIZON MARYLAND INC. Methods and Procedures
More informationMay 2016 DIVISION 3 - CW 2145-R4 TABLE OF CONTENTS
May 2016 CW 2145 - SEWER AND MANHOLE INSPECTION TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Referenced Standard Construction Specifications... 1 3. CONSTRUCTION METHODS... 1 3.1 Inspection
More informationSECTION 686 VIDEO DECODER DESCRIPTION
686 SECTION 686 VIDEO DECODER DESCRIPTION 686.01.01 GENERAL A. This specification describes the functional, performance, environmental, submittal, documentation, and warranty requirements, as well as the
More informationViztrac AM200 User s Guide. Page 1 of 12
AM200 User s Guide Page 1 of 12 TABLE OF CONTENTS Diagram & Equipment Specifications 3 Equipment Specifications & Safety Instructions.. 4 Control Panel. 5 AM200. 6 AM200 Sonde Operation. 6 AM200 DVR Operation
More informationELIGIBLE INTERMITTENT RESOURCES PROTOCOL
FIRST REPLACEMENT VOLUME NO. I Original Sheet No. 848 ELIGIBLE INTERMITTENT RESOURCES PROTOCOL FIRST REPLACEMENT VOLUME NO. I Original Sheet No. 850 ELIGIBLE INTERMITTENT RESOURCES PROTOCOL Table of Contents
More informationThis SOP is applicable to all WMATA personnel working on the Rail System, contractors performing the work and WMATA contractor escorts.
RFP: FQ13024/WJG CONTRACT NO. FQ13024 APPENDIX C STANDARD OPERATING PROCEDURES (SOP) SOP #33 REMOVAL AND RESTORATION OF THIRD RAIL POWER FOR WORK BY CONTRACTOR S FORCES MAINLINE, REVENUE SYSTEM PURPOSE
More informationHONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA
Section 00000 SECURITY ACCESS AND SURVEILLANCE HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA PART 1 GENERAL 1.01 SUMMARY The intent of this document is to specify the minimum criteria for the
More informationGLI-12 V1.1 GLI 12 V2.0
1.41 Other Standards. These standards cover the actual requirements for various types of progressive gaming devices in casinos. The following other standards may apply: a) Technical Standards for Gaming
More informationAWT150C/AWT150CS/ AWT151C CCD Camera
AWT150C/AWT150CS/ AWT151C CCD Camera ISSUED OCTOBER 2018 WARNING Failure to follow all instructions and safety precautions in this manual, in the vehicle and body manufacturers' manuals and on the safety
More informationADDENDUM NO. 1 FDVA-ITB B ITB TITLE: JENKINS AUDIO/VIDEO SECURITY SYSTEM ISSUE DATE: THURSDAY, JUNE 30, 2016
Glenn Sutphin Interim Executive Director State of Florida DEPARTMENT OF VETERANS AFFAIRS Division of Administration and Public Information 11351 Ulmerton Road, #311-K Largo, FL 33778-1630 Phone: (727)
More informationAerial Cable Installation Best Practices
Aerial Cable Installation Best Practices Panduit Corp. 2007 BEST PRACTICES Table of Contents 1.0 General... 3 2.0 Introduction... 3 3.0 Precautions... 4 4.0 Pre-survey... 5 5.0 Materials and Equipment...
More information9I273 01/10/2012 COU-03/0 AUTOMATIC CHANGEOVER UNIT TO BACK-UP AMPLIFIER
9I273 01/10/2012 COU-03/0 1 CONTENTS 1. SPECIFICATIONS... 3 2. BLOCKS DIAGRAM... 3 3. FRONT VIEW... 4 4. REAR VIEW... 4 5. CONTROL MODULE... 4 6. ZONE CARD (COU-03FC or COU-03EC)... 6 6.1. Diagram... 6
More informationGAMING COMMISSION REGULATIONS ESTABLISHING MINIMUM STANDARDS FOR SECURITY AND SURVEILLANCE
GAMING COMMISSION REGULATIONS ESTABLISHING MINIMUM STANDARDS FOR SECURITY AND SURVEILLANCE Coyote Valley Gaming Commission Coyote Valley Band of Pomo Indians Chapter 5 MINIMUM STANDARDS FOR SECURITY AND
More informationMetuchen Public Educational and Governmental (PEG) Television Station. Policies & Procedures
Metuchen Public Educational and Governmental (PEG) Television Station Policies & Procedures TABLE OF CONTENTS Introduction 3 Purpose 4 Station Operations 4 Taping of Events 4 Use of MEtv Equipment 5 Independently
More informationTHE MINACK THEATRE. Notes for Playing Companies. Please note 2016 amendment to Section 5 - Public Liability & Employer Liability Insurance
THE MINACK THEATRE Notes for Playing Companies 2018 Please note 2016 amendment to Section 5 - Public Liability & Employer Liability Insurance Please note 2017 amendment to Section 9 Child Performers Please
More informationSPECIAL SPECIFICATION 6735 Video Optical Transceiver
2004 Specifications CSJ 0924-06-244 SPECIAL SPECIFICATION 6735 Video Optical Transceiver 1. Description. This Item governs the furnishing and installation of Video optical transceiver (VOTR) in field location(s)
More informationRADIO STATION AUTHORIZATION Current Authorization : FCC WEB Reproduction
Nature Of Service: Nature Of Service: Class Of Station: Domestic Fixed Satellite Service Fixed Satellite Service Temporary Fixed Earth Station A) Site Location(s) ) Site ID Address Latitude Longitude Elevation
More informationSPECIAL SPECIFICATION 6713 Ethernet Video Decoder (MPEG-4)
2004 Specifications CSJ 0016-04-103, etc. SPECIAL SPECIFICATION 6713 Ethernet Video Decoder (MPEG-4) 1. Description. Furnish, install, and make fully operational with the TransGuide or Combined Transportation,
More informationSIGNALPERSON REFERENCE MANUAL
NATIONAL COMMISSION FOR THE CERTIFICATION OF CRANE OPERATORS (NCCCO) SIGNALPERSON REFERENCE MANUAL SGP RM 10/10 This page intentionally left blank Hold Harmless/Release/Disclaimer Agreement The reading
More informationBased on our maintenance efforts, during the second quarter of 2018, Comcast s plant was 99.9% reliable.
December XX, 2018 Comcast Cable 253 Najoles Road Millersville,MD 21108 Terry Shannon County Administrator 175 Main Street Prince Frederick, MD 20678 Dear Mrs. Shannon, The purpose of this letter is to
More informationSECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA
SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA TABLE OF CONTENTS Section Title Page 5901 GENERAL... 2 5902 DESIGN CRITERIA... 2 5902.1 Codes and Standards... 2 5902.2 Signal
More informationSTATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 2002
STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 02 872.01 Description 872.02 Prequalification 872.03 Material Requirements
More informationCHARLOTTE MECKLENBURG PUBLIC ACCESS CORPORATION
CHARLOTTE MECKLENBURG PUBLIC ACCESS CORPORATION REGULATIONS & PROCEDURES A. MISSION STATEMENT Effective 12/19/18 1. Charlotte Mecklenburg Public Access Corporation (CMPAC) was created to manage and operate
More informationSpecial Specification 6293 Adaptive Traffic Signal Control System
Special Specification Adaptive Traffic Signal Control System 1. DESCRIPTION 2. MATERIALS Furnish, install, relocate, or remove adaptive traffic signal control (ATSC) system software and equipment at locations
More information1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT
1995 Metric CSJ 0508-01-258 SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT 1.0 Description This Item shall govern for the furnishing and installation of color Single
More informationDesign and Manufacture of Video Pipeline Inspection Systems A Full Service Company
Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company www.rstechserv.com Omni III Pan and Tilt Color Camera Modell 10-01610 OPERATIONS MANUAL Made in USA IMPORTANT SAFETY NOTICE
More informationSPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment
1993 Specifications CSJ 0500-01-117 SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic Video
More informationNOW THEREFORE, in consideration of the mutual covenants and conditions herein contained, the parties hereto do hereby agree as follows:
NOW THEREFORE, in consideration of the mutual covenants and conditions herein contained, the parties hereto do hereby agree as follows: ARTICLE 1 RECOGNITION AND GUILD SHOP 1-100 RECOGNITION AND GUILD
More informationAMPHITHEATRE APPLICATION & INFORMATION. types of performances. Concessions facilities and limited restroom facilities are provided.
AMPHITHEATRE APPLICATION & INFORMATION The floating stage has 1,600 square feet of performance space under the retractable vinyl fabric canopy and 300 square feet of back stage, including two small dressing
More informationUser Instructions. 16 SCB Sync Station.
User Instructions 16 SCB Sync Station Contents Overview... 1 Specifications... 1 Compliance and approvals... 2 Safety instructions... 3 Set up... 4 How to charge multiple devices... 4 How to synchronize
More informationSPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel
1993 Specifications CSJ 0924-06-223 SPECIAL SPECIFICATION 1160 8:1 Video (De) Mux with Data Channel 1. Description. This Item shall govern for furnishing and installing an 8 channel digital multiplexed
More informationSPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment
1993 Specifications CSJ 0027-12-086, etc. SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of color
More informationAcquisition Control System Design Requirement Document
Project Documentation SPEC-0188 Rev A Acquisition Control System Design Requirement Document Bret Goodrich, David Morris HLSC Group November 2018 Released By: Name M. Warner Project Manager Date 28-Nov-2018
More information(1) These Regulations may be called PEMRA Standards for Cable Television Regulations 2003.
PEMRA Cable Television (Operations) Regulations, 2002. Pakistan Electronic Media Regulatory Authority (PEMRA) The Pakistan Electronic Media Regulatory Authority (PEMRA) is pleased to make the Standards
More informationNew York MX700 Room. PWD-NY5-MX700-P60 List Price: $11, SLA Price: $1,100.00/year (Other options available See Appendix B)
New York MX700 Room PWD-NY5-MX700-P60 List Price: $11,000.00 SLA Price: $1,100.00/year (Other options available See Appendix B) Statement of Work (SoW) Project Summary RoomReady will install the following
More informationDESIGN!!GUIDELINES!!!!!
DESIGNGUIDELINES 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 1. Testing General 1.1. For acceptance, 100% of the media
More informationWork Type Definition and Submittal Requirements. Work Type Definition: Traffic Signal Design
The first section, Work Type Definition, provides a detailed explanation of the work type. The second section, Work Type Submittal Requirements, identifies the requirements a firm must meet to become pre-qualified
More informationInstruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1
Instruction Manual 2.4G Digital Wireless Four Channel Transmitter System RVS-554W 1 NOTE! Please read all of the installation instructions carefully before installing the product. Improper installation
More informationTroubleshooting Guide 9630 Series
Troubleshooting Guide 9630 Series Satellite Solutions for Mobile Markets 11200 Hampshire Avenue South, Bloomington, MN 55438-2453 Phone: (800) 982-9920 Fax: (952) 922-8424 www.kingcontrols.com 1305-SEMI
More informationSECTION COMMERCIAL DOOR OPERATORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08 71 13 COMMERCIAL DOOR OPERATORS Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2010-2010 ARCAT, Inc. - All rights reserved ** NOTE TO SPECIFIER ** Overhead Door Corporation;
More informationSPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment
2004 Specifications CSJ 3256-02-079 & 3256-03-082 SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 1. Description. Furnish and install Fiber Optic Video Data Transmission Equipment
More informationToronto Hydro - Electric System
Toronto Hydro - Electric System FIT Commissioning Requirements and Reports Comments and inquiries can be e-mailed to: FIT@torontohydro.com Customers without e-mail access can submit through regular mail
More informationForensic Video Analysis Technical Procedure Manual Page 1
Forensic Video Analysis Technical Procedure Manual Page 1 Introduction The following technical procedures apply primarily to the use of the AVID Forensic Video System currently in use in the Documents
More informationHOME THEATER. Super IR Accessories. Vanco Part Numbers. Technical Support
HOME THEATER Super Accessories Vanco Part Numbers 280703 280720 280721 Technical Support www.vanco1.com info@vanco1.com 800-626-6445 DEAR CUSTOMER Thank you for purchasing this product. For optimum performance
More informationFixed Signals - Rules 1 to 23
Applicability VIC Publication Requirement External Only Document Status Issue/Revision # Effective from 1 07 August 2011 0 04 October 2015 1 01 July 2018 Australian Rail Track Corporation Limited (ARTC)
More informationSECTION TESTING OF COPPER CABLES
SECTION 27 08 13 TESTING OF COPPER CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction,
More informationEngineering Instruction
Engineering Instruction Electrical Distribution Unit Approved by: Paul Poynton, A/Professional Head Electrical Engineering, Sydney Trains Authorised by: Jonathon McKinnon, Engineering Technical Publications
More informationA. Section Includes: Division 1 applies to this section. Provide GPS wireless clock system, complete.
SPECIFICATIONS GPS Wireless Clock System Section 16730 TIME SYSTEM PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: Division 1 applies to this section. Provide GPS wireless clock system, complete. B.
More informationLED Spot 300W. Please read this user manual before your operation
LED Spot 300W Please read this user manual before your operation 1. Introduction 2. General Guideline 3. Safety Instructions 4. Cleaning and Maintenance 5. Technical Parameters 6. DMX Channels 7. Remark
More informationClass B digital device part 15 of the FCC rules
Class B digital device part 15 of the FCC rules The Federal Code Of Regulation (CFR) FCC Part 15 is a common testing standard for most electronic equipment. FCC Part 15 covers the regulations under which
More informationCITY OF DIXON REQUEST FOR PROPOSAL
CITY OF DIXON REQUEST FOR PROPOSAL PROFESSIONAL AND SPECIALIZED SERVICES FOR REMOVAL AND REPLACEMENT OF AUDIO AND VIDEO EQUIPMENT IN THE CITY COUNCIL CHAMBER FOR THE CITY OF DIXON Publishing Date: November
More information1. Entries must be received or post-marked no later than 5:00 p.m., NOVEMBER 25, Faxed, or late entries will not be accepted.
GOVERNMENT OF NEWFOUNDLAND AND LABRADOR ARTS AND LETTERS AWARDS 2017 The aim of the annual Arts and Letters Awards is to stimulate creative talent in the Province by awarding prizes in various sections
More informationLancaster Performing Arts Center RENTAL FEES and Policies
Physical Address: Mailing Address: City of Lancaster 750 West Lancaster Blvd ATTN: LPAC Rental Office Lancaster, CA 93535-3816 44933 Fern Ave LPAC Rental Administrator (661) 723-5932 www.lpac.org PMartindale@CityofLancasterCA.org
More informationRecommended Guidelines for Developing Standard Operating Procedures
Scientific Working Groups on Digital Evidence and Imaging Technology Recommended Guidelines for Developing Standard Operating Procedures Disclaimer: As a condition to the use of this document and the information
More information-Technical Specifications-
Annex I to Contract 108733 NL-Petten: the delivery, installation, warranty and maintenance of one (1) X-ray computed tomography system at the JRC-IET -Technical Specifications- INTRODUCTION In the 7th
More informationSPECIAL SPECIFICATION 1118 Dual OC-3 ATM MPEG-2 Encoder
1993 Specifications CSJ 0521-04-190 SPECIAL SPECIFICATION 1118 Dual OC-3 ATM MPEG-2 Encoder 1. Description. Furnish, install, and make fully operational an Asynchronous Transfer Mode (ATM) Video Encoder
More informationDVI Over Cat5 2x2 Matrix Switch. Model: B
WARRANTY REGISTRATION Register online today for a chance to win a FREE Tripp Lite product www.tripplite.com/warranty Owner s Manual DVI Over Cat x Matrix Switch Model: B10-0 Package Contents Product Features
More informationSECTION INTERCOMMUNICATIONS AND PROGRAM SYSTEMS
SECTION 27 51 23 SPEC WRITER NOTES: 1. Use this section only for NCA projects. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Contact Department of Veterans
More informationOperation Manual VMS 3.0 Video System
Operation Manual VMS 3.0 Video System for the AlterG Anti-Gravity Treadmill 1 This manual covers operation procedures for the following AlterG products: AlterG Video System model VMS 3.0 NOTE: The following
More informationName: Type of Art (please be specific): Make checks payable to: Temple Railroad & Heritage Museum, 315 W. Ave. B, Temple, TX,
The Temple Railroad & Heritage Museum 2 nd Annual Transcontinental Art Fair AUGUST 19 & 20, 2017 VENDOR APPLICATION Name: Company Name: Address: City/State: Email Address: Telephone: Home Cell Type of
More informationHD VIDEO IP STREAMER CT-HDVD-HDSTR-KIT
www. nacebrands.com HD VIDEO IP STREAMER CT-HDVD-HDSTR-KIT MADE IN CHINA Read this user manual carefully before using this product. Pictures shown in this manual are for reference only. Safety Precaution
More informationSECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION
683 SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION 683.01.01 GENERAL A. The Contractor shall furnish the designated quantity of Video Optical Transceiver (VOTR) pairs
More informationA. The Cable Operator shall provide Subscribers a toll-free or local telephone number for installation, service, and complaint calls.
I. STANDARDS A. The Cable Operator shall provide Subscribers a toll-free or local telephone number for installation, service, and complaint calls. B. Telephone and Office Availability. The Cable Operator
More informationHOME THEATER. HDMI HDBaseT Lite Extenders. Vanco Part Number: Technical Support
HOME THEATER HDMI HDBaseT Lite Extenders Vanco Part Number: 280766 280767 Technical Support www.vanco1.com info@vanco1.com 800-626-6445 DEAR CUSTOMER Thank you for purchasing this product. For optimum
More informationINFORMATION TECHNOLOGY POLICY FOR THE RENTAL OF. The Township of Radnor Conference Rooms and Equipment
INFORMATION TECHNOLOGY POLICY FOR THE RENTAL OF The Township of Radnor Conference Rooms and Equipment Revised March 1, 2015 CONTENTS A. Summary... 1 B. General Policy... 2 C. Conference Room 1. Rental
More informationIBAK Made in Germany. IBAK Helmut Hunger GmbH & Co. KG Wehdenweg Kiel Germany Tel. +49 (0) Fax +49 (0)
IBAK Made in Germany All IBAK products have one thing in common: They are "made in Germany". All system components are developed, produced, installed and tested by IBAK. Due to their high quality standard,
More informationUser Manual. Model 1351 DVI Repeater with HDCP
User Manual Model 1351 DVI Repeater with HDCP 2 Table Of Contents 1.0 Introduction....................... 4 2.0 Specifications...................... 5 3.0 Checking Package Contents............... 7 4.0
More informationCITY OF LOS ANGELES CIVIL SERVICE COMMISSION CLASS SPECIFICATION POSTED JUNE VIDEO TECHNICIAN, 6145
CITY OF LOS ANGELES CIVIL SERVICE COMMISSION CLASS SPECIFICATION POSTED JUNE 1999 04-26-96 VIDEO TECHNICIAN, 6145 Summary of Duties: Operates municipal access equipment for City departments, City Council
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR SURVEILLANCE SYSTEM, REMOTE SITE. ITS:CLC 1 of 7 APPR:LWB:DBP: FHWA:APPR:
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR SURVEILLANCE SYSTEM, REMOTE SITE ITS:CLC 1 of 7 APPR:LWB:DBP:07-15-16 FHWA:APPR:07-29-16 a. Description. This work consists of furnishing, installing,
More informationPRODUCT MANUAL : 1x8 Splitter/Extender : Receiver (Sold Separately)
PRODUCT MANUAL Product Name: S-VGA Splitter/Extenders over Category 5e/Cat6 Cable Part Numbers: 90-12116: 1x2 Splitter/Extender 90-12112: 1x8 Splitter/Extender 90-12113: Receiver (Sold Separately) WARNING:
More informationAttachment 2 Wastewater
Attachment 2 Wastewater 1 Overview 11 Objective The objective of this attachment is to set the minimum controls for planning and implementing flow isolation / flow management (FIFM) to ensure the safety
More informationFlorida Department of Education CURRIUCULUM FRAMEWORK. Digital Television and Media Production
Florida Department of Education CURRIUCULUM FRAMEWORK December 2001 Program Title: Occupational Area: CIP Number Grade Level Length Certification Digital Television and Media Production Industrial Education
More informationTECHNICAL BULLETIN. Ref. No. P (Repl P-03-11)
0 TECHNICAL BULLETIN August 2006 Ref. No. P-06-01 (Repl P-03-11) Guidelines for Selection of Replacement Tires --Including Substitute Tire Sizes-- With Important Safety Information To ensure the same performance
More informationHEALTH AND SAFETY MANUAL
HEALTH AND SAFETY MANUAL Title: Grounding Conductor Program Approved by: Greg Savoy Rev. 4/1/08 1 Purpose/Scope: The purpose of this program is to provide requirements to reduce employee potential for
More informationTelecommunication Infrastructure Project September 20, 2002
PART 1 - GENERAL 1.1 SECTION INCLUDES A. Testing Publications and Standards B. Category rated UTP systems shall be provided and tested in accordance with the performance level established in Specification
More informationTROUBLESHOOTING GUIDE
TROUBLESHOOTING GUIDE Digital HDTV Over-the-Air Antennas 11200 Hampshire Avenue South, Bloomington, MN 55438 PH 952.922.6889 FAX 952.922.8424 kingconnect.com NOTE: Depending on the model, KING Jack antennas
More informationCASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS
CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS Cass County, Michigan invites qualified vendors to submit proposals for the purchase, installation, and programming of a centralized
More informationInnis College Rental Terms & Conditions
Innis College Rental Terms & Conditions 1. Innis College rental spaces are defined as Innis Town Hall (199 seat cinema and adjacent shared lobby space), the Innis Café complex (interior seating area, rooftop
More informationIn this document, the Office of Management and Budget (OMB) has approved, for a
This document is scheduled to be published in the Federal Register on 09/11/2013 and available online at http://federalregister.gov/a/2013-22121, and on FDsys.gov 6712-01 FEDERAL COMMUNICATIONS COMMISSION
More informationColour Explosion Proof Video Camera USER MANUAL VID-C
Colour Explosion Proof Video Camera USER MANUAL VID-C Part Number: MAN-0036-00 Rev 4 Copyright 2002 Net Safety Monitoring Inc. Printed in Canada This manual is provided for informational purposes only.
More informationVerizon NY Section 2 Network Services Issue C, December, 2001
Verizon NY Section 2 Evaluating Requests 2.01 While inquiries for information will be accepted in any form, requests for licensing agreements regarding Pole Attachments, Conduit Occupancy and/or (private
More informationHOME THEATER. HDMI Selector Switches. Vanco Part Numbers (5x1) (3x1) Technical Support
HOME THEATER HDMI Selector Switches Vanco Part Numbers 280710 (5x1) 280711 (3x1) Technical Support www.vanco1.com info@vanco1.com 800-626-6445 DEAR CUSTOMER Thank you for purchasing this product. For optimum
More informationOwner s Manual HDMI over Cat5 Active Extender
Owner s Manual HDMI over Cat5 Active Extender Models: B126-1A1-U and B126-1A0-U PROTECT YOUR INVESTMENT! Register your product for quicker service and ultimate peace of mind. You could also win an ISOBAR6ULTRA
More informationORDER FORM FOR SPECIALTY SERVICES OF MOVIE FILM RECOVERY AND SCANNING OF WARPED, SHRUNK OR DAMAGED FILM (Film in poor condition)
ORDER FORM FOR SPECIALTY SERVICES OF MOVIE FILM RECOVERY AND SCANNING OF WARPED, SHRUNK OR DAMAGED FILM (Film in poor condition) TEAMWORK MEDIA LAB 5662A Longbeach Rd. Nelson BC Canada V1L6N9 PHONE: 1-(250)
More informationSafety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.
Table of Contents Introduction...3 Safety Information...4-6 Before Beginning Installation...7 Installation Guide...8 Wiring Camera & Monitor...9-10 Replacement Installation Diagram...11 Clip-On Installation
More information