SECTION MASTER TELEVISION ANTENNA SYSTEM (MTAS)

Size: px
Start display at page:

Download "SECTION MASTER TELEVISION ANTENNA SYSTEM (MTAS)"

Transcription

1 PART 1 GENERAL 1.1 SCOPE OF WORK SECTION MASTER TELEVISION ANTENNA SYSTEM (MTAS) A. The extent of the master television antenna system (MTAS) work is hereby defined to include (but not by way of limitation) the furnishing and installing of a system. 1.2 QUALITY ASSURANCE A. Manufacturers: Firms regularly engaged in the manufacture of MTA systems of the type required, and which have been in satisfactory use for not less than five-years in similar services. B. Electrical Standards: Provide tested, listed, and labeled UL electrical products complying with NEMA standards. C. Installation and testing of the system shall be verified by a SCTE (Society of Telecommunications Engineers) certified BCT (Broadband Communications Technician) or BDS (Broadband Distribution Specialist) certified installer. 1.3 SUBMITTALS A. Submittals on MTA systems are required as follows 1. Shop Drawings 2. Riser Diagram 3. Wiring Diagram 4. Manufacturer's Data 5. Manufacturer's Product Warranty 6. Operating Instructions 7. Maintenance Manuals PART 2 PRODUCTS 2.1 Provide the required MTA system products in the sizes and capacities indicated, complying with the manufacturer's published product information. 2.2 Apply complete weatherproofing methods at the time of installations. A. Do not leave any coaxial fittings uncovered or exposed at any time during installation. B. Use a non-hardening silicone base compound. 2.3 The following specifications apply to all receiving antennas and their supporting structures. A. The references in all cases apply to the entire structure for wind loading and stability. 1 Construct all supporting structures and antennas based on ASCE 7 for velocity of 140 mph; embedment of ITV tower shall be in accordance with actual soil condition. 2 Support parabolic antennas on structures whose twist and sway under 65 mph winds shall not exceed the following limit schedule: Antenna Diameter Twist Sway Six foot Architect s Project Number of 5 Master Television Antenna System

2 B. Construct parabolic antennas to withstand wind forces per ASCE 7 on a minimum force as listed below. 1 Consider these forces in the top loading of supporting structures. 2 Submit manufacturer's specifications for any support structure other than a simple galvanized (inside and out) pipe of at least 3" inside diameter having an unsupported length of not more than 6'. 3 Embed a minimum 4' of the supporting pipe into the concrete pole, properly secured and bonded to the concrete pole. 4 Due to casting requirements, the remaining 6' is field attached. 5 Threaded connections alone are not acceptable provide additional fastening of the pipes by welding or bolting. C. Wind loadings table for parabolic antennas of solid sheet metal construction shall be as per ASCE 7 wind loads or minimum forces as follows: 1 Antenna Diameter Force Lbs. (Minimum) 2 Six foot 2200 D. Support connecting leads between antennas and receivers against wind abrasion, and provide waterproof connectors according to manufacturer's recommendations. 1 Antenna line shall be 50-Ohm Heliax, ⅜" Foam Dielectric, Andrew Part Number LDF2-50, or approved equal in writing by the SDPBC TEN Department. 2 Connectors shall be male N Type, Andrew Part Number L2PNM (silver plated body/gold plated pin). 3 Antenna line runs from antenna connector to junction box (20"x 20"x 6") at the base of the tower installed over the hand hole. E. Receiver down converter shall be; attached to antenna line N connector; transmission-line compression connector; and electrical ground at J box, at the base of the tower. F. Each receiving antenna installation shall require the following submittal data: 1 Calculations substantiating structural integrity of the tower and foundation or mounting assembly, certified by a Florida registered engineer. 2 Layout of the concrete self-supporting tower with structural details showing specific construction procedures, such drawing shall be complete. 3 All design shall be governed by applicable sections of EIA Manual RS222-A, Manual of Steel Construction of the AISC, Standards of ACI, FBC, and other nationally recognized codes for materials under consideration not stated above. 4 All outside hardware, including tower hardware shall be hot-dipped galvanized or equivalent with same or better anti-rust characteristics for our tropical climate. 5 Provide a drawing of installed electrical ground system with verified test results (five Ohms or less). G. May substitute alternate manufacturers on all equipment and cables, providing they equal or exceed the physical and electrical specifications of the indicated manufacturers. 1 Submit alternate manufactured materials for approval 14 days prior to bid. 2 The SDPBC TEN Department shall approve alternate manufacturers in writing. H. Change the 6' grid antenna requirement to 3' grid (P-25A36GNU) for facilities close to the broadcast towers as directed by the TEN Department. 1 Verify with the Project Engineer. 2 Provide Gabriel P-25A36GN-U Antenna. 2.4 Provide hot-dipped galvanized steel or stainless steel structural metals supporting structures. 2.5 Protect self-supporting concrete tower from climbing by unauthorized personnel. Architect s Project Number of 5 Master Television Antenna System

3 A. Ladder rungs shall start 20 feet above ground on the side opposite antenna azimuth. B. Provide "U" shaped ladder rungs embedded in tower. C. Ladder rungs shall be spaced not less than 12' or more than 20' apart. 2.6 Receiver output cables shall be in conduit from tower to building entry and protected against water and abrasion. A. Supporting structures for antennas shall have a certified grounding system. B. The system shall include as a minimum a lightning dissipater at the top of the tower and a lightning suppressor Polyphaser Model IS-MT50LN-ME in the junction box at the base of the tower. C. Install the system in accordance with NFPA 780. D. A contractor licensed in this field shall certify grounding system. E. Provide written certification to the District Project Manager. F. Provide a copy of this report to the SDPBC TEN Department. 2.7 Antenna height shall be no less than 100' above grade level unless pre-approved by School District. 2.8 Select the height and size of dish to provide a 50 DB Carrier to noise ratio, at the output of the down converter receiver. A. Contractor may have to add a 2.5 GHz attenuator to the input side of the down converter in very high signal areas to prevent down converter overload. 2.9 Down converter receiver shall be Conifer Model HLN-3 (EBS), with power supply Furnish a down converter power, supply with the down converter System distribution amplifier is Blonder-Tongue BID A-55A-50 or approved equal In addition to the ITV system distribution, provide an additional Digital Broadcast Headend located in the Media Center Production Room. A. Connect the Digital Broadcast Headend to the system distribution with four RG-6(Belden 1694A) cables and provided with a dedicated 120VAC, 20AMPS quad receptacle. B. Provide a Digital Broadcast Headend manufactured by Toner Cable Equipment Company. C. Vendor/Contractor may refer to the School District Bid to receive the same price as the District. D. Interconnect and test the Digital Broadcast Headend prior to shipment. 1 Only signal inputs and outputs need to be connected and aligned for proper operation Terminate all trunk lines in 75-ohm devices and provide a power receptacle within 12" of every ITV outlet All feeder lines shall have a 30db return VHF when terminated in 75 Ohm A lightning dissipater is required to be the highest point of the tower. A. Use a Lightning Master Corp. Candelabrum Model CA-48-C, substitution is not permitted (sole source approved by the School Board). Architect s Project Number of 5 Master Television Antenna System

4 2.16 Provide a 20"x20"x6" weatherproof junction box at the base of the tower, installed over the hand hole. A. Provide a quad power receptacle inside this junction box Terminal cabinets shall be 24" x 24" x 6" surface mounted with hinged lockable cover, ½" thick plywood backboard, painted light gray. PART 3 EXECUTION 3.1 WIRING OF NEW/REMODELED/RENOVATED BUILDINGS A. Use a single feed (parallel output) from the head end to each main classroom building, administration building, cafeteria, media center, and auditorium. 1 Areas such as gym and ancillary buildings will be considered a pass-through feed from adjacent building. 2 Each main classroom building, administration building, elementary school cafeteria, media center, and auditorium shall have an amplifier housed in an 18" x 18" x 6" terminal cabinet and provide tandem (use of taps connected in series) feeds and pass through feeds for multiple floors and adjacent buildings. 3 All multiple outlets will be tandem (in/out). 4 All tandem feeds will be in 1" conduit and all building and pass through feeds will be in 2" conduit. 5 All tandem feeds will be Belden 1694A and all building and pass through feeds will be Belden 7731A. a. Belden 1694A is sole sourced by the School Board, substitutions not allowed. 6 Origination lines will be point (origination) to point (head end) and will be Belden 1694A (under 800') and Belden 7731A (over 800'). 7 Splices not permitted in underground and/or above ceiling pull boxes and junction boxes. B. The norm output of distribution amplifier should not exceed 44 dbmv; this prohibits the BER (bit error rate) from exceeding limitations. C. No cable assemblies (jumpers) can be less than 12" long. D. Trunk lines shall be copper shielded, solid copper core conductor, PVC jacketed, RG6 digital ready equal to Belden number 1694A with Thomas Betts SNS6 (Blue) compression fittings, use tools recommended by the manufacturer. 1 Until underground cable, suitable for wet locations and digital ready, is available, use Belden number 7731A (RG11) with Thomas Betts SNS11 (Black) compression fittings. Use manufacturer recommended tools. E. All couplers, taps, and splitters should be 120 db RFI shielded for digital television. 1 Devices shall be with soldered back plates and labeled digital ready, use Blonder Tongue. 2 Devices with epoxy back plates are not acceptable. F. Signal testing of the head-end and distribution system shall be accomplished prior to contract completion; with or without tower signal source. 1 May use a CATV signal of 175 MHZ to 405 MHZ 2 Test all outlets, including origination outlets. 3 Provide the signal readings to the ITV Department. G. The installer shall have minimum of 5-years successful experience in CATV distribution Cabling. 3.2 ADDITIONAL SPECIFICATIONS Architect s Project Number of 5 Master Television Antenna System

5 A B C D E F G H Weatherproof all outside connectors, including down converter and antenna connectors. No cross-modulation, co-channel, or adjacent channel or any type of interference shall be noticeable at any TV outlet, using a standard color TV set, and viewed by a trained observer. The internal distribution system shall provide signals to each television receiver outlet, on each channel, at levels not less that +6 dbmv, nor greater than +18 dbmv. The C/N (carrier to noise) ratio of the overall MATV system shall not be less than 50 db, measured at the most remote outlet from the main amplifier or the lowest output tap, whichever provides the lowest signal. Conduit from tower top shall be 2" unobstructed PVC to 5" hand hole. 1 Install a 20" x 20" x 6" WP junction box over the hand hole at the base of the tower. 2 Conduit from junction box shall be 2" galvanized pipe, 10' minimum to the pull box. Any substitutions for equipment listed in this specification must have the same degree of repair ability as well as the same technical characteristics or better. 1 School District TEN Department must approve substitutions in writing before installation. Provide a drawing of the grounding system as installed to the Project Manager and a copy sent to the ITV Department. Install a 3" conduit with pull-wire from ITV head-end cabinet to the property for future cable television connection. 1 Verify and coordinate exact location of the conduit termination point at property line with local cable television provider. 3.3 DEMONSTRATION AND TRAINING A B Training of the Owner s operation and maintenance personnel is required in cooperation with the Owner's Representative. 1 Provide competent, factory authorized personnel to provide instruction to operation and maintenance personnel concerning the location, operation, and troubleshooting of the installed systems. 2 Schedule the instruction in coordination with the Owner's Representative after submission and approval of formal training plans. 3 Refer to Section , Commissioning, for further contractor training requirements. Provide demonstration and training for all types of MTAS installed in this project. END OF SECTION Architect s Project Number of 5 Master Television Antenna System

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE)

Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE) PART 1: GENERAL 1.01 Telecommunications Engineer Minimum qualifications for the Telecommunications Engineer are: A. Texas Licensed Profession Engineer (PE) B. Registered Communications Distribution Designer

More information

TELEVISION/RADIO FREQUENCY SYSTEMS

TELEVISION/RADIO FREQUENCY SYSTEMS SECTION 13780 TELEVISION/RADIO FREQUENCY SYSTEMS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Installations at new facilities without operational television/radio frequency systems and requiring

More information

***************************************************************************************************************

*************************************************************************************************************** 13780 TELEVISION/RADIO FREQUENCY DISTRIBUTION SYSTEMS SPECIFIER: CSI MasterFormat 2004 number 27 41 35 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Installations of a complete, operational, television/radio

More information

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School BILOXI PUBLIC SCHOOL DISTRICT Biloxi Junior High School Request for Proposals E-Rate 2014-2015 - Internal Connections Submit Proposals To: Purchasing Department Attn: Traci Barnett 160 St. Peter Street

More information

A. The requirements of Section govern the work specified in this section.

A. The requirements of Section govern the work specified in this section. SECTION 27 05 10 - COMMUNITY ANTENNA TELEVISION CABLING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The requirements of Section 27 01 00 govern the work specified in this section. B. Refer to the following

More information

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Telecommunciations Infrastructure Project September 20, A. Broadband radio frequency active and passive components

Telecommunciations Infrastructure Project September 20, A. Broadband radio frequency active and passive components PART 1 - GENERAL 1.1 SECTION INCLUDES A. Broadband radio frequency active and passive components B. Broadband optical active and passive components C. Coaxial cable and connectors D. Support and termination

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 54 00.00 20 (April 2006) -------------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-16783N (February 2003) UNIFIED FACILITIES GUIDE

More information

Telecommunication Infrastructure Project September 20, 2002

Telecommunication Infrastructure Project September 20, 2002 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Testing Publications and Standards B. Category rated UTP systems shall be provided and tested in accordance with the performance level established in Specification

More information

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE Prepared in cooperation and approval from BICSI Building Industry Consulting Services International and

More information

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1.

California Polytechnic State University ITS Telecommunications PART 1 GENERAL SECTION AUDIO VISUAL STATION CABLES 1. PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated

More information

PLU-TV & AT&T CATV CLASSROOM/OFFICE BUILDING EQUIPMENT LISTS & DIAGRAMS CLT CATV.doc CENTER FOR LEARNING & TECHNOLOGY (CLT)

PLU-TV & AT&T CATV CLASSROOM/OFFICE BUILDING EQUIPMENT LISTS & DIAGRAMS CLT CATV.doc CENTER FOR LEARNING & TECHNOLOGY (CLT) Page 1 08-21-01 PLU-TV & AT&T CATV CLASSROOM/OFFICE BUILDING EQUIPMENT LISTS & DIAGRAMS CLT CATV.doc CENTER FOR LEARNING & TECHNOLOGY (CLT) The following is a list of equipment needed to cable and provide

More information

IndyGo Facility Upgrades Project 35671EE

IndyGo Facility Upgrades Project 35671EE SECTION 260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Identification for raceways. 2. Identification of power and control cables. 3. Identification for

More information

Bravo AV s Structured or Whole-House Wiring Approach

Bravo AV s Structured or Whole-House Wiring Approach Custom Audio & Video Systems: Design and Installation Bravo AV s Structured or Whole-House Wiring Approach THE QUALITY OF THE CABLE YOU USE IS CRITICALLY IMPORT TO THE PERFORMANCE OF YOUR SYSTEM Introduction

More information

Public Works Division Lighting District Fiber Optic Specifications April 2009

Public Works Division Lighting District Fiber Optic Specifications April 2009 Public Works Division Lighting District Fiber Optic Specifications April 2009 7000 Florida Street Punta Gorda, Florida 33950 Tele: 941.575.3600 Fax : 941.637.9265 www.charlottecountyfl.com/publicworks

More information

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel 1993 Specifications CSJ 0924-06-223 SPECIAL SPECIFICATION 1160 8:1 Video (De) Mux with Data Channel 1. Description. This Item shall govern for furnishing and installing an 8 channel digital multiplexed

More information

SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA

SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA TABLE OF CONTENTS Section Title Page 5901 GENERAL... 2 5902 DESIGN CRITERIA... 2 5902.1 Codes and Standards... 2 5902.2 Signal

More information

384A Adapter Installation Instructions

384A Adapter Installation Instructions Instruction Sheet 860237684 Issue 9, October 2012 SYSTIMAX Solutions 384A Adapter Installation Instructions General The 384A adapter (Figure 1) is a broadband video adapter that provides connectivity to

More information

STRUCTURED CABLE SYSTEM (SCS)

STRUCTURED CABLE SYSTEM (SCS) PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-27 05 14.00 10 (April 2006) -------------------------------- Preparing Activity: USACE Superseding UFGS-27 05 14.00 10 (April 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

A. As defined in Section Telecommunications General Requirements

A. As defined in Section Telecommunications General Requirements PART 1 - GENERAL 1.1 SECTION INCLUDES A. Related Sections B. Applicable Publications C. Conditions D. Scope E. Compliance, Tests, and Inspections F. Delivery and Storage of Materials G. Coordination of

More information

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents PART 1 - GENERAL 1.1 SUMMARY SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors. 3. Cabling system identification products. 1.2

More information

INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM

INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM ATTENTION: READ THE ENTIRE INSTRUCTION SHEET BEFORE STARTING THE INSTALLATION PROCESS. WARNING! Do not begin to install your

More information

AMERICAN NATIONAL STANDARD

AMERICAN NATIONAL STANDARD Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 129 2017 Drop Passives: Bonding Blocks (Without Surge Protection) NOTICE The Society of Cable Telecommunications Engineers (SCTE) Standards

More information

A. Section Includes: Division 1 applies to this section. Provide GPS wireless clock system, complete.

A. Section Includes: Division 1 applies to this section. Provide GPS wireless clock system, complete. SPECIFICATIONS GPS Wireless Clock System Section 16730 TIME SYSTEM PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: Division 1 applies to this section. Provide GPS wireless clock system, complete. B.

More information

ULTIMATE SNAP-N-SEAL

ULTIMATE SNAP-N-SEAL ULTIMATE SNAP-N-SEAL F Series Compression Connectors Thomas & Betts introduces the Ultimate Snap-N-Seal Compression Connector, the newest addition to the Snap-N-Seal system. Look for the classic design

More information

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes. SECTION 33 71 49.23 MEDIUM VOLTAGE CABLE INSTALLATION PART 1 GENERAL 1.1 SCOPE A. Work included in this Section: Medium Voltage Cable (4 kv and 12 kv) Installation and Termination. Removal and return of

More information

SPECIAL SPECIFICATION 6559 Telecommunication Cable

SPECIAL SPECIFICATION 6559 Telecommunication Cable 2004 Specifications CSJ 0015-09-147, etc. SPECIAL SPECIFICATION 6559 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing, training,

More information

A. Provide a complete coaxial cable distribution system for CATV as specified here in and as shown in the Contract Documents.

A. Provide a complete coaxial cable distribution system for CATV as specified here in and as shown in the Contract Documents. Page 1 of 15 Specifier All reference in the specifiers that asks for or infers coordination or approval by UWIT must be coordinated through the CPO Project Manager. This specification is for Projects that

More information

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98)

Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98) Mediacom Upgrade/Splicing Procedures (based on original document from Corporate dated 4/16/98) 1. Splicing specifications are provided by Mediacom, but due to resplice conditions, many locations become

More information

Drop Passives: Splitters, Couplers and Power Inserters

Drop Passives: Splitters, Couplers and Power Inserters ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 153 2016 Drop Passives: Splitters, Couplers and Power Inserters NOTICE The Society of Cable Telecommunications

More information

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017 Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM-2017-2 Date: 05/26/2017 Additional specification information for data communication to cameras and between Library

More information

AMERICAN NATIONAL STANDARD

AMERICAN NATIONAL STANDARD ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 153 2008 Drop Passives: Splitters, Couplers and Power Inserters NOTICE The Society of Cable Telecommunications

More information

University Center AV Integration Construction Documents February 8, 2012

University Center AV Integration Construction Documents February 8, 2012 SECTION 27 41 30 AUDIOVISUAL ARCHITECTURAL SPACES PART 1 GENERAL 1.01 SUMMARY A. This Section defines the Audiovisual System requirements for Audiovisual Systems within Architectural Spaces. 1.02 RELATED

More information

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment 1993 Specifications CSJ 0027-12-086, etc. SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of color

More information

SPECIAL SPECIFICATION 8540 Telecommunication Cable

SPECIAL SPECIFICATION 8540 Telecommunication Cable 2004 Specifications CSJ 0914-00-307 & CSJ 0914-25-003 SPECIAL SPECIFICATION 8540 Telecommunication Cable 1. Description. This specification governs the materials, installation, termination, splicing, testing,

More information

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION 683 SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION 683.01.01 GENERAL A. The Contractor shall furnish the designated quantity of Video Optical Transceiver (VOTR) pairs

More information

A. All communications equipment rooms shall be installed in a neat and workmanlike manner.

A. All communications equipment rooms shall be installed in a neat and workmanlike manner. SECTION 27 11 00 - COMMUNICATIONS EQUIPMENT ROOM FITTINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Target Interface / Construction Compliance Inspection Checklist

Target Interface / Construction Compliance Inspection Checklist A. Targets Quantities meet DD, applicable TC -, and CEHNC Design Guide 0-- (Standard is single UTOs and Double UTOs) B. Roads-Service, Lanes Adequate access is provided to the and AAR D. Testing Results-provided

More information

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project 1.1.0 GENERAL The purpose of this specification is to establish a requirement for the installation of a voice, video and data cable network. The cable (copper), wire, hardware, equipment racks, jumpers,

More information

Michigan State University Construction Standards EXTERIOR FIBER OPTIC CABLE SYSTEM PAGE

Michigan State University Construction Standards EXTERIOR FIBER OPTIC CABLE SYSTEM PAGE PAGE 271800-1 SECTION 271800 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT 1995 Metric CSJ 0508-01-258 SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT 1.0 Description This Item shall govern for the furnishing and installation of color Single

More information

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cable Management and Ladder Rack

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cable Management and Ladder Rack PART 1 GENERAL 1.1 WORK INCLUDED Section 27 11 00 COMMUNICATION EQUIPMENT ROOM FITTINGS Section 27 11 23 Communications Cable Management and Ladder Rack A. Provide all labor, materials, and equipment for

More information

8341LS PRODUCT SPECIFICATIONS MODEL 8341LS LED BASEBALL SCOREBOARD OUTDOOR SCOREBOARD. Baseball 10-Inning Line Score

8341LS PRODUCT SPECIFICATIONS MODEL 8341LS LED BASEBALL SCOREBOARD OUTDOOR SCOREBOARD. Baseball 10-Inning Line Score OUTDOOR SCOREBOARD 8341LS Baseball 10-Inning Line Score OVERALL DIMENSION INFORMATION DISPLAYED DIGITS INDICATORS CAPTIONS HORN CONSTRUCTION STANDARD COLORS (Custom Colors Available) 9 1/2 high x 32 wide

More information

DESIGN!!GUIDELINES!!!!!

DESIGN!!GUIDELINES!!!!! DESIGNGUIDELINES 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 1. Testing General 1.1. For acceptance, 100% of the media

More information

BLONDER TONGUE LABORATORIES, INC.

BLONDER TONGUE LABORATORIES, INC. BLONDER TONGUE LABORATORIES, INC. One Jake Brown Road, P.O. Box 1000 Tel: (732) 679-4000 Old Bridge, NJ 08857-1000 USA Fax: (732) 679-4353 DESIGNING THE DISTRIBUTION SYSTEM DISTRIBUTION SYSTEM Since the

More information

Colour Explosion Proof Video Camera USER MANUAL VID-C

Colour Explosion Proof Video Camera USER MANUAL VID-C Colour Explosion Proof Video Camera USER MANUAL VID-C Part Number: MAN-0036-00 Rev 4 Copyright 2002 Net Safety Monitoring Inc. Printed in Canada This manual is provided for informational purposes only.

More information

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 103 2018 Test Method for DC Contact Resistance, Drop cable to F connectors and F 81 Barrels NOTICE The Society of Cable Telecommunications

More information

Lyndhurst Secondary Technology Package Addendum # Bid Date: Wednesday, August 30, 1:00PM. Items issued in this addendum:

Lyndhurst Secondary Technology Package Addendum # Bid Date: Wednesday, August 30, 1:00PM. Items issued in this addendum: Lyndhurst Secondary Technology Package Addendum #7 8.29.2017 Bid Date: Wednesday, August 30, 2017 @ 1:00PM Items issued in this addendum: A. Contractor questions and responses B. Clarifications A. Contractor

More information

Interactive Satellite Terminal Installation / Validation Manual

Interactive Satellite Terminal Installation / Validation Manual Installation / Validation Manual Version October 5, 2016 Index INTERACTIVE SATELLITE TERMINAL 1. FCC COMPLIANCE... 3 2. TECHNICAL FEATURES...4 3. GENERAL DESCRIPTION...5 4. ELEMENTS CONTAINED IN THE TERMINAL...6

More information

INSTALLATION INSTRUCTIONS FOR

INSTALLATION INSTRUCTIONS FOR INSTALLATION INSTRUCTIONS FOR MODEL 2240LED www.sportablescoreboards.com 1 Table of Contents 8 X 7 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:... 3 INSTRUCTIONS FOR

More information

MESA FIXED AUTOMATIC. Andrews/Raven Installer Manual // MESA. Rev 23 June MESA A/R Installation

MESA FIXED AUTOMATIC. Andrews/Raven Installer Manual // MESA. Rev 23 June MESA A/R Installation MESA FIXED AUTOMATIC // MESA Andrews/Raven Installer Manual 901-MESA A/R Installation Rev 23 June 10 A/R Installer Manual WHAT IS A MESA The MESA is a three (3) axis (Azimuth, Elevation and Skew) Automatic

More information

32 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall)

32 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall) 32 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall) NOTE: All of these documents are in PDF format located at www.steltronicusa.com To install the 32 LCD

More information

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras Eng Installation Instructions F D E NL I IMPORTANT SAFEGUARDS 1. Read Instructions All the safety and operating instructions should be read before

More information

INSTALLATION MANUAL. CT-DUC-DDC Digital Off-Air Up Converter and Down Converter

INSTALLATION MANUAL. CT-DUC-DDC Digital Off-Air Up Converter and Down Converter INSTALLATION MANUAL CT-DUC-DDC Digital Off-Air Up Converter and Down Converter 1 PACKAGE CONTENTS This package contains: One CT-DUC Digital Off-Air Up Converter One CT-DDC Digital Off-Air Down Converter

More information

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1993 Specifications CSJ 0500-01-117 SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment 1. Description. This Item shall govern for the furnishing and installation of Fiber Optic Video

More information

PERFORMANCE SPECIFICATIONS*

PERFORMANCE SPECIFICATIONS* PERFORMANCE SPECIFICATIONS* 18T-2127 26T-2127 Reflector Material Mounting Hardware Gain Input Frequency** -3 db Beam Width Cross Polarity Rejection Front to Back Ratio Impedance @ Output Elevation Adjustment

More information

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA

HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA Section 00000 SECURITY ACCESS AND SURVEILLANCE HONEYWELL VIDEO SYSTEMS HIGH-RESOLUTION COLOR DOME CAMERA PART 1 GENERAL 1.01 SUMMARY The intent of this document is to specify the minimum criteria for the

More information

42 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall)

42 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall) 42 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall) NOTE: All of these documents are in PDF format located at www.steltronicusa.com To install the 42 LCD

More information

Broadband System - D

Broadband System - D Broadband System - D Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz TV TRANSMITTER Headend

More information

BUSD Ramona Middle School Gymnasium Project AV Project

BUSD Ramona Middle School Gymnasium Project AV Project BUSD Ramona Middle School Gymnasium Project AV Project Scope: Provide all part necessary for the completion of an AV System for the new Middle School Gymnasium per the attached parts lists and drawings.

More information

Directional Couplers and Splitters

Directional Couplers and Splitters Directional couplers and splitters divide trunk and feeder lines. 17-Amp current handling capacity. Excellent hum-modulation performance. 1/2-inch hard-line ports have extra length, creating a better seal

More information

CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS

CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS Cass County, Michigan invites qualified vendors to submit proposals for the purchase, installation, and programming of a centralized

More information

Primex Wireless, Inc. July, Wells Street Lake Geneva, WI

Primex Wireless, Inc. July, Wells Street Lake Geneva, WI Division 0 0 0 0 Primex Wireless, Inc. July, 00 Wells Street Lake Geneva, WI 00--0 www.primexwireless.com Product Guide Specification Specifier Note: This product specification is written according to

More information

DLP ANTENNA INSTRUCTION MANUAL. Dielectric LLC 22 Tower Road Raymond, Maine Phone:

DLP ANTENNA INSTRUCTION MANUAL. Dielectric LLC 22 Tower Road Raymond, Maine Phone: DLP ANTENNA INSTRUCTION MANUAL Dielectric LLC 22 Tower Road Raymond, Maine 04071 Phone: 800-341-9678 TABLE OF CONTENTS Section Title Page Warnings 1 Return Policy. 1 Factory Tests... 1 Antenna Description....

More information

ICS Digital Menu. Installation Guide Version 1.1

ICS Digital Menu. Installation Guide Version 1.1 ICS Digital Menu Installation Guide Version 1.1 Installation Overview This document was written to assist technicians and electricians in installing the ICS Digital Menu. A thorough understanding of electrical

More information

42 LCD Overhead Video Display Support Specifications Electricity required on the rear curtain wall

42 LCD Overhead Video Display Support Specifications Electricity required on the rear curtain wall 42 LCD Overhead Video Display Support Specifications Electricity required on the rear curtain wall NOTE: All of these documents are in PDF format located at www.steltronicusa.com To install the 42 LCD

More information

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 2004 Specifications CSJ 3256-02-079 & 3256-03-082 SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment 1. Description. Furnish and install Fiber Optic Video Data Transmission Equipment

More information

SECTION COMMUNICATIONS HORIZONTAL CABLING

SECTION COMMUNICATIONS HORIZONTAL CABLING SECTION 271500 COMMUNICATIONS HORIZONTAL CABLING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. UTP cabling. 2. Telecommunications outlet/connectors including patch panels. 3. Cabling identification

More information

CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS

CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS CASS COUNTY, MICHIGAN CASSOPOLIS, MI REQUEST FOR PROPOSAL SPECIFICATIONS Cass County, Michigan invites qualified vendors to submit proposals for the purchase, installation, and programming of: a door card

More information

SCIR. Infrared Illuminator Powerful Indoor/Outdoor IR Spotlight SCIR

SCIR. Infrared Illuminator Powerful Indoor/Outdoor IR Spotlight SCIR SCIR Infrared Illuminator Powerful Indoor/Outdoor IR Spotlight The NetMedia SCIR Infrared (IR) Illuminator provides night vision for IR (850nm) sensitive cameras. It enables cameras such as NetMedia s

More information

Site Installation Model MP-8433

Site Installation Model MP-8433 Site Installation Model MP- Rev. //0 SCOREBOARD SITE INSTALLATION INSTRUCTIONS CAUTION: All American Scoreboards (AAS) recommends the sign be installed by a licensed contractor, and must meet all local

More information

Professionally Install Products Right the First Time. TOOL-CRIMP Radial Linear compression tool for BNC, F & RCA connectors

Professionally Install Products Right the First Time. TOOL-CRIMP Radial Linear compression tool for BNC, F & RCA connectors Professionally Install Products Right the First Time Profit with PROFIT Tributaries PROFIT System ProFit System employs radial compression technology which preserves the coaxial cables critical 75 ohm

More information

QCA9-33 Active Combiner

QCA9-33 Active Combiner Product Manual QCA9-33 Active Combiner April 13, 2012 Table of Contents Table of Contents... 2 Overview... 3 Specifications... 4 Installation... 5 Basic Setup... 5 16-Channel Operation... 5 16-64 Channel

More information

SECTION CONTROL, COMMUNICATION AND SIGNAL WIRING

SECTION CONTROL, COMMUNICATION AND SIGNAL WIRING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 27 10 00 CONTROL, COMMUNICATION AND SIGNAL WIRING SPEC WRITER NOTES: 1. Edit this specification section between // //, to fit project, or delete if not applicable.

More information

INSTALLATION MANUAL. CTMS-516RKPS Rack Mount Satellite Multiswitch

INSTALLATION MANUAL. CTMS-516RKPS Rack Mount Satellite Multiswitch INSTALLATION MANUAL CTMS-516RKPS Rack Mount Satellite Multiswitch 1 PACKAGE CONTENTS This package contains: One CTMS-516RKPS Rack Mount Satellite Multiswitch One CTMS-516RKPS Installation Manual PRODUCT

More information

Serial Digital BNC Connectors

Serial Digital BNC Connectors Broadcast Catalog Stock Check Distributor Serial Digital BNC Connectors Bomar s true 5 ohm BNC connectors fit all standard broadcast cables and utilize standard existing tooling. Made from precision machined

More information

REQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus

REQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus REQUEST FOR QUOTE: TELECOMMUNICATIONS CABLING Library/Classroom Building, Beltline Campus PART 1: GENERAL REQUIREMENTS A. Contractor Work 1. Provide and install (except as noted in this document), cable,

More information

LYNX ULTRA Series Hubs and Baluns

LYNX ULTRA Series Hubs and Baluns Introducing The New LYNX ULTRA Series Hubs and Baluns 4K and HDTV on Cat 6 Cable Product Highlights 800 Digital RF Channels Distributed on Cat 5 or Cat 6 Cable 860 MHz over 100 Meters 4K, 8K, HD or SD

More information

Preparing a home for TransACT fibre-to-the-premise (FTTP) services

Preparing a home for TransACT fibre-to-the-premise (FTTP) services Preparing a home for TransACT fibre-to-the-premise (FTTP) services A guide for builders, telecommunications cablers and home owners transact.com.au For more information call TransACT s FTTP Sales Manager,

More information

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED INSTALLATION INSTRUCTIONS FOR MODEL 2230LED www.sportablescoreboards.com 1 Table of Contents MODEL 2230LED... 3 8 X 4 INDOOR SCOREBOARD... 3 THE SCOREBOARD SYSTEM SHOULD INCLUDE THE FOLLOWING PARTS:...

More information

Multi-Media Installation Guide

Multi-Media Installation Guide Multi-Media Installation Guide Coaxial Page 2 Data Plug Page 7 Data Jack Page 10 Telephone Page 13 Splicing Page 15 Cable Types Cable Types Two basic types of cable are used in multimedia installations.

More information

CONSTRUCTION SPECIFICATION FOR TRAFFIC SIGNAL EQUIPMENT

CONSTRUCTION SPECIFICATION FOR TRAFFIC SIGNAL EQUIPMENT ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS.PROV 620 APRIL 2017 CONSTRUCTION SPECIFICATION FOR TRAFFIC SIGNAL EQUIPMENT TABLE OF CONTENTS 620.01 SCOPE 620.02 REFERENCES 620.03 DEFINITIONS 620.04

More information

Interactive Satellite Terminal Installation / Validation Manual

Interactive Satellite Terminal Installation / Validation Manual Installation / Validation Manual Version September 14, 2017 Index INTERACTIVE SATELLITE TERMINAL 1. FCC COMPLIANCE... 3 2. TECHNICAL FEATURES...4 3. GENERAL DESCRIPTION...5 4. ELEMENTS CONTAINED IN THE

More information

Register your product and get support at SDV5122/27. EN User manual

Register your product and get support at   SDV5122/27. EN User manual Register your product and get support at www.philips.com/welcome SDV5122/27 User manual Contents 1 Important 4 Safety 4 Notice for USA 5 Notice for Canada 5 Recycling 6 English 2 Your SDV5122 7 Overview

More information

SECTION 7 -- CROSS-CONNECT SYSTEMS

SECTION 7 -- CROSS-CONNECT SYSTEMS DETAIL ENGINEERING REQUIREMENTS AT&T March, 2016 Section 7, ATT-TP-76400 Revised NA SECTION 7 -- CROSS-CONNECT SYSTEMS CONTENTS PAGE 1. GENERAL... 7-2 1.1. Introduction... 7-2 1.2. Cable Holes... 7-2 1.3.

More information

DESIGN STANDARD FOR AUDIOVISUAL SYSTEMS

DESIGN STANDARD FOR AUDIOVISUAL SYSTEMS DESIGN STANDARD FOR AUDIOVISUAL SYSTEMS General: The SCC is intent on moving to 21 st century unified communications and data systems, consistent with industry standards and best practices as they evolve.

More information

Register your product and get support at www.philips.com/welcome SDV5222T/27 User manual Contents 1 Important 4 Safety 4 Notice for USA 4 Notice for Canada 5 Recycling 5 English 2 Your SDV5222T 6 Overview

More information

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

SPECIAL SPECIFICATION 6735 Video Optical Transceiver 2004 Specifications CSJ 0924-06-244 SPECIAL SPECIFICATION 6735 Video Optical Transceiver 1. Description. This Item governs the furnishing and installation of Video optical transceiver (VOTR) in field location(s)

More information

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD 1 INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD NOTE TO INSTALLERS: PLEASE RETURN THIS MANUAL TO THE INDIVIDUAL IN CHARGE OF THE SCOREBOARD UPON COMPLETION OF INSTALLATION. The scoreboard

More information

MESA FIXED AUTOMATIC. PRODELIN Installer Manual // MESA. Rev 23 June MESA Prodelin Installation

MESA FIXED AUTOMATIC. PRODELIN Installer Manual // MESA. Rev 23 June MESA Prodelin Installation MESA FIXED AUTOMATIC // MESA PRODELIN Installer Manual 901-MESA Prodelin Installation Rev 23 June 10 WHAT IS A MESA The MESA is a three (3) axis (Azimuth, Elevation and Skew) Automatic Fixed Mounting system.

More information

Register your product and get support at www.philips.com/welcome SDV8625T/27 User manual Contents 1 Important 4 Safety 4 For indoor use 4 For outdoor use 4 Notice for USA 4 Notice for Canada 5 Recycling

More information

HexPort Multi-Band Antenna

HexPort Multi-Band Antenna DATA SHEET Four foot (1.2 m), multi-band, six port antenna with a 33 azimuth beamwidth optimized for covering 817-869 MHz and 1850-1995 MHz / 2496-2690 MHz frequencies Four high band ports covering Band

More information

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM CCTV Central Equipment 1993 Specifications CSJ 0922-33-042, etc. SPECIAL SPECIFICATION ITEM 8549 CCTV Central Equipment 1. Description. This Item shall govern for the furnishing and installation of closed circuit television

More information

Section Communications Optical Fiber Backbone Cabling

Section Communications Optical Fiber Backbone Cabling Part 1 1.1 Related Documents 1.1.1 Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specifications Sections apply to this Section. 1.2 Related

More information

ADDENDUM NO. 2 This addendum consists of 8 pages. Kenai Peninsula Borough Purchasing & Contracting

ADDENDUM NO. 2 This addendum consists of 8 pages. Kenai Peninsula Borough Purchasing & Contracting KENAI PENINSULA BOROUGH Purchasing and Contracting 144 North Binkley Street Soldotna, Alaska 99669-7520 Toll-free within the Borough: 1-800-478-4441, Ext. 2260 PHONE: (907) 714-2260 FAX: (907) 714-2373

More information

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE AND COMPONENTS. July 19, 2013

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE AND COMPONENTS. July 19, 2013 804.01 Description 804.02 General 804.03 Materials 804.04 Warranties 804.05 Fiber Optic Cable 804.06 Fan-Out Kit 804.07 Drop Cable 804.08 Fiber Optic Patch Cord 804.09 Fiber Termination Panel 804.10 Fusion

More information

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA Operating Manual Automated Gear Apollo Design Technology, Inc. 4130 Fourier Drive Fort Wayne, IN 46818 USA PH: +01(260)497-9191 FX: +01(260)497-9192 www.apollodesign.net 11-25-09 5-6 POWERING UP THE RIGHT

More information

Audio/Visual for Lower Level and Board Room A2.0 Projector:

Audio/Visual for Lower Level and Board Room A2.0 Projector: Audio/Visual for Lower Level and Board Room A2.0 Projector: A2.1 Projector must meet or exceed the following specifications: A2.1.1 3LCD imaging engine capable of native WXGA (1024x768) resolution. A2.1.2

More information

QDA4-44 RF Amp/Combiner

QDA4-44 RF Amp/Combiner Product Manual QDA4-44 RF Amp/Combiner May 17, 2012 Table of Contents Table of Contents... 2 Overview... 3 Specifications... 4 Installation... 5 Basic Setup... 5 Rack Mounting... 6 RK2 Dual Rack Kit with

More information