Digital output modules
|
|
- Barrie Malone
- 5 years ago
- Views:
Transcription
1 Appendix 374 Digital output modules Order number Figure Type DO 8xDC 24V 2A DO 16xDC 24V 1A DO 16xDC 24V 2A DO 16xDC 24V 0.5A manual operation General information Note Features 8 outputs, in groups of 4, 16 outputs, in groups of 8, 16 outputs, in groups of 8, 16 outputs, 1 input (activation for outputs) Output voltage 2 A Output current 1 A Output voltage 2 A 16 switches (automatic, manual 0/1), Output voltage 0.5 A SPEED-Bus Current consumption/power loss Current consumption from backplane bus 65 ma 110 ma 110 ma 100 ma Power loss 7.5 W 4 W 4 W 6 W Technical data digital outputs Number of outputs Cable length, shielded 1000 m 1000 m 1000 m - Cable length, unshielded 600 m 600 m 600 m 600 m Rated load voltage DC 24 V DC 24 V DC 24 V DC 24 V Current consumption from load voltage L+ 68 ma 30 ma 30 ma 140 ma (without load) Output current at signal "1", rated value 2 A 1 A 2 A 0.5 A Output delay of "0" to "1" max. 100 µs Output delay of "1" to "0" max. 500 µs Minimum load current Lamp load 10 W 5 W 10 W 5 W Parallel switching of outputs for redundant control of a load Parallel switching of outputs for increased power posible (only outputs group) posible (only outputs group) - - posible (only outputs group) - - not possible Actuation of digital input Switching frequency with resistive load max Hz max Hz max Hz max Hz Switching frequency with inductive load max. 0.5 Hz max. 0.5 Hz max. 0.5 Hz max. 0.5 Hz Switching frequency on lamp load max. 1 Hz max. 1 Hz max. 1 Hz max. 10 Hz Internal limitation of inductive shut-off L+ (-52 V) L+ (-52 V) L+ (-52 V) L+ (-52 V) voltage Short-circuit protection of output yes, electronic yes, electronic yes, electronic yes, electronic Trigger level 3 A 1.5 A 3 A 1 A Number of operating cycle of relay outputs
2 Digital output modules Signal modules digital Order number Switching capacity of contacts Output data size 1 Byte 2 Byte 2 Byte 2 Byte Status information, alarms, diagnostics Status display green LED per channel green LED per channel green LED per channel green LED per channel Interrupts no no no no Process alarm no no no no Diagnostic interrupt no no no no Diagnostic functions no no no no Diagnostics information read-out none none none none Supply voltage display green LED per group green LED per group green LED per group green LED per group Group error display red SF LED red SF LED red SF LED red SF LED Channel error display none none none none Isolation Between channels - Between channels of groups to Between channels and backplane bus Insulation tested with DC 500 V DC 500 V DC 500 V DC 500 V Mechanical data Dimensions (WxHxD) Weight 240 g 230 g 230 g 230 g Environmental conditions Operating temperature 0 C to 60 C 0 C to 60 C 0 C to 60 C 0 C to 60 C Storage temperature -25 C to 70 C -25 C to 70 C -25 C to 70 C -25 C to 70 C Certifications UL508 certification yes yes yes yes Appendix 375
3 Appendix Connections, Interfaces 1L+ 1M 2L+ 2M 376
4 1L+ 1M 2L+ 2M Digital output modules Signal modules digital Appendix 377
5 Appendix 378 Digital output modules Order number Figure Type SM 322S, DO 16xDC 24V 0.5A General information Output current 0.5 A DO 32xDC 24V 1A DO 16xRelay DO 8xAC 120/230V Note Features SPEED bus, 16 fast outputs, 32 outputs, in groups of 8, 16 relay outputs, in groups of 8, AC 230 V/ DC 30 V, 8 outputs, in groups of 1, AC 120/230 V, Output current 1 A Contact rating per channel 5 A Output current 2 A, Substitute value output (programmable) SPEED-Bus Current consumption/power loss Current consumption from backplane bus 390 ma 200 ma 80 ma 100 ma Power loss 4 W 5 W 4 W 8.6 W Technical data digital outputs Number of outputs Cable length, shielded 1000 m m Cable length, unshielded 600 m 600 m 600 m 600 m Rated load voltage DC 24 V DC 24 V DC 30 V/ AC 230 V AC 120/230 V Current consumption from load voltage L+ 30 ma 30 ma - - (without load) Output current at signal "1", rated value 0.5 A 0.5 A 4 A 2 A Output delay of "0" to "1" Output delay of "1" to "0" Minimum load current Lamp load 5 W 6 W 6 W 50 W Parallel switching of outputs for redundant possible control of a load Parallel switching of outputs for increased not possible power Actuation of digital input - - Switching frequency with resistive load max. 100 khz max Hz - max. 10 Hz Switching frequency with inductive load max. 0.5 Hz max. 0.5 Hz - max. 0.5 Hz Switching frequency on lamp load max. 10 Hz max. 1 Hz - max. 1 Hz Internal limitation of inductive shut-off L+ (-52 V) L+ (-52 V) L+ (-52 V) L+ (-52 V) voltage Short-circuit protection of output yes, electronic yes, electronic yes, electronic Fuse 3.15 A /250 V, quick response Trigger level 1 A 1.7 A 1 A - Number of operating cycle of relay outputs Switching capacity of contacts Output data size 2 Byte 4 Byte 2 Byte 1 Byte
6 Digital output modules Signal modules digital Order number Status information, alarms, diagnostics Status display green LED per channel green LED per channel green LED per channel green LED per channel Interrupts no no no no Process alarm no no no no Diagnostic interrupt no no no no Diagnostic functions no no no no Diagnostics information read-out none none none none Supply voltage display green LED per group green LED per group none none Group error display red SF LED red SF LED none red SF LED Channel error display none none none none Isolation Between channels - - Between channels of groups to Between channels and backplane bus Insulation tested with DC 500 V DC 500 V DC 500 V AC 1500 V Mechanical data Dimensions (WxHxD) Weight 250 g 260 g 290 g 330 g Environmental conditions Operating temperature 0 C to 60 C 0 C to 60 C 0 C to 60 C 0 C to 60 C Storage temperature -25 C to 70 C -25 C to 70 C -25 C to 70 C -25 C to 70 C Certifications UL508 certification yes yes yes yes Appendix 379
7 Appendix Connections, Interfaces 1M 1L+ 1M 2L+ 2M 3M 2M 4M 380
8 M Digital output modules Signal modules digital Appendix 381
SOFTLINK 300. Modules Specifications. Reference Manual
SOFTLINK 300 Reference Manual Edition 04/2011 Preface Purpose of the manual This manual gives you a brief overview of SOFTLINK 300 Modules. You can look up information on the description, order No., technical
More informationMagnecraft Power Relays
Description DPST-NO, 30 A; DPDT, 30 A (NO) / 3 A (NC) Description The series power relays offer a small package size and features Class F insulation for a maximum coil temperature of 55 C (3 F). These
More information02/11/2015
DIN Rail Mount 17.5 mm MUS/MUSF 80 AC/DC Part number 84872141 Control relays monitoring their own power supply - MUS : Over/undervoltage control Selectable latching (memory) function - MUSF : Over/undervoltage
More informationTeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40
Characteristics Type of contactor LC- LC- LC- LC- LC-D & D09 D8 D2 D38 D40 D0 D9 LC-D0 DT20 & DT2 DT32 & DT40 Environment Rated insulation voltage (Ui) Conforming to IEC 947-4-, overvoltage category III,
More informationAssembly. Front view. LEDs. Parametrization interface. Power Bus
otation Speed Monitor Features Assembly 1-channel signal conditioner 2 V DC supply Input for 2- or -wire sensors Input frequency 10 mhz... 50 khz elay contact output Start-up override and restart inhibit
More informationAdvantys STB DATA SHEET. Advantys STB Output Module. Description. Features
Advantys STB Advantys STB Output Module DATA SHEET Description The Advantys model STBDAO5260 Digital Output Module provides 2 isolated discrete output points that operate on a 115 VAC power source. The
More informationFibre Optic Modem ODW-611
Fibre Optic Modem ODW-611 PROFIBUS DP to fibre optic link, point-to-point applications The ODW-611 is a fibre optic modem designed for point-to-point fibre optic connections between PROFI- BUS DP networks.
More informationFibre Optic Modem ODW-622
Fibre Optic Modem ODW-622 RS-232 to fibre optic link, redundant ring or multidrop applications The ODW-622 can be used to create either redundant ring or multidrop solutions for devices with RS-232 interfaces.
More informationA V 50Hz / V 60Hz
A16-22-00 400-415V 50Hz / 415-440V 60Hz Products Low Voltage Products and Systems Control Products Contactors Block Contactors General Information Extended Product Type: A16-22-00 400-415V 50Hz / 415-440V
More informationInterface Relays and Optocouplers Product group picture
Interface Relays and Optocouplers Product group picture /1 ABB Catalog 2CDC 1 004 C0208 Interface Relays and Optocouplers Table of contents Interface Relays and Optocouplers Interface Relays and Optocouplers
More informationCapacitance Limit Detection nivotester FTC 420/421/422
Technical Information TI 127F/00/en Capacitance Limit Detection nivotester FTC 420/421/422 Limit switches in Minipac design for liquids and bulk solids Application Nivotester FTC 420...422 capacitive limit
More informationODW-621. RS-232 Point-to-point applications
Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to
More informationSoft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit
DATASHEET - S811+N66N3S Delivery program Soft starter, 66 A, 200-600 V AC, Us= 24 V DC, with control unit, Frame size N Part no. S811+N66N3S Catalog No. 168978 Eaton Catalog No. S811PLUSN66N3S EL-Nummer
More informationDatasheet - SRB-E-201ST
27.04.2016-16:36:21h Datasheet - SRB-E-201ST Multi-function safety modules / SRB-E-201ST STOP 0 Function 1 oder 2-channel control Start button / Auto-start Monitoring two-hand control panels to EN 574
More informationDimming actuators GDA-4K KNX GDA-8K KNX
Dimming actuators GDA-4K KNX GDA-8K KNX GDA-4K KNX 108394 GDA-8K KNX 108395 Updated: May-17 (Subject to changes) Page 1 of 67 Contents 1 FUNCTIONAL CHARACTERISTICS... 4 1.1 OPERATION... 5 2 TECHNICAL DATA...
More informationLONWORKS Fibre Optic Converter
LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring
More informationPluggable interface relays CR-M Miniature relays
2CDC 293 035 F0004 CR-M 1 2 4 3 5 Features Standard miniature relays with mechanical status indication 12 different supply voltages: DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 125 V, 220 V AC versions:
More informationLONWORKS Fibre Optic Router
LONWORKS Fiber Optic Router LRW-112 and LRW-112/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-112 router offers an easy way to extend the distance between LONWORKS
More informationAnalogue output module DAO 081
ANALOGUE OUTPUT MODULE DAO 081 Analogue output module DAO 081 for eight ±10 V DC outputs This analogue output module is used for driving components capable of being analogue driven (e.g. proportional pressure
More informationSIMATIC. ET 200S distributed I/O 2AO U HS analog electronic module (6ES7135-4FB52-0AB0) Preface. Properties 1. Parameters 2.
SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO U HS analog electronic module (6ES7135-4FB52-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation
More informationMagnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A
and 3DPT, 10 A UL Listed when used with proper Magnecraft s The 750R series octal base, plug-in relays offer clear or full-feature covers with multiple mounting options and accessories. 750R 750R Full-Feature
More informationAnalog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/
> 8 channels for 2-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module
More informationOperating instructions Electronic preset counter Type series 717
Operating instructions Electronic preset counter Type series 717 1. Description 5.98.3_gb 6-digit adding/subtracting counter with two presets Very bright 8mm high LED display Counting and preset range
More information10 SERIES. Light dependent relays A
10 SERES 10 SERES Relays for automatic control of lighting according to the ambient light level ntegral light sensor For pole or wall mounting 10.32-2 O 16 A output contacts 10.41-1 O 16 A output contact
More informationPluggable interface relays CR-M Miniature relays
2CDC 293 035 F0004 1 2 4 3 5 Features Standard miniature relays with mechanical status indication 12 different supply s: DC versions: 12 V, 24 V, 48 V, 60 V, 110 V, 125 V, 220 V AC versions: 24 V, 48 V,
More information4.0 Description. 2-channel operation D1 and D2 rated at 200 VA each. 1-channel operation D1 rated at 400 VA (see connection chap. 6.
_307 238_EN_LUXOR 405_310 410 01_D.qxd 21.09.16 10:54 Seite 1 Operating Manual Dimmer module 4050100 1.0 Designated use The LUXOR dimmer module expands the existing LUXOR series of devices. It switches
More informationLC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC
Product datasheet Characteristics LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC Price* : 86.25 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category
More informationK-BUS Dimmer Module User manual-ver. 1
K-BUS Dimmer Module User manual-ver. 1 KA/D0103.1 KA/D0203.1 KA/D0403.1 Content 1. Introduction... 3 2. Technical Parameter... 3 3. Dimension and Connection Diagram... 4 3.1 KA/D0103.1... 4 3.2 KA/D0203.1...
More informationMAP110 AC-DC Series Data Sheet
Description Single-Output Model Selection VOLTAGE RANGE OUTPUT CURRENT OUTPUT CURRENT REGULATION REGULATION %p-p (NOTE 1) ACCURACY MAP110-1005 5V 4.95V to 5.50 16A 2 0.2% 1% 1% 5.09V to 5.11V MAP110-1012
More informationFibre optic router for TP/FT-10 LRW-112PP
Fibre optic router for TP/FT-10 LRW-112PP Lo n Wo r k s to fibre optic link, point-to-point applications The LRW-112PP router offers an easy way to extend the distance between LONWORKS 78 kbit/s TP/FT
More informationAnalog Input Module HART Ex n Inputs, 8 Channels Series 9461/15
> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit >
More informationLC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product datasheet Characteristics LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationALLEN BRADLEY TIMING RELAY
ALLEN BRADLEY TIMING RELAY Configuration Details Product: 700-HS12BA1 Description: 700-HS General Purpose Square Base Timing Relay, On Delay Timer, 1.0 to 180 seconds, DPDT, 120V AC 50/60Hz CONTROL RELAY
More informationDimming actuators of the FIX series DM 4-2 T, DM 8-2 T
Dimming actuators of the FIX series DM 4-2 T, DM 8-2 T DM 4-2 T 4940280 DM 8-2 T 4940285 Updated: Jun-16 (Subject to change) Page 1 of 70 Contents 1 FUNCTIONAL CHARACTERISTICS... 4 1.1 OPERATION... 5 2
More informationDatasheet - SRB301LC 24VAC/DC
25.02.2016-18:05:23h Datasheet - SRB301LC 24VAC/DC Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301LC Preferred
More informationLC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil
Product datasheet Characteristics LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationClimatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC
Deliveryprogramme Contactorrelay,3N/O+1N/C,AC Partno. DILER-31(230V50HZ,240V60HZ) Articleno. 051768 CatalogNo. XTRM10A31F Product range DILER Mini-contactors Application Contactor relays Description with
More informationActuators IC 20, IC 40
Actuators IC 20, IC 40 IC 20 for basic applications with three-point step control and automatic/manual mode changeover for easy commissioning IC 40 for complex applications with programmable functions
More information4-in-1 Motor Controller CAN
4-in-1 Motor Controller CAN Page 1 of 6 Version 1.10 Technical Data Construction Connector Housing Dimensions Weight Ambient Temperature Protection Class Plastic housing with side flaps 2x Tyco JPT 90
More informationSH2RE16A4. Output relay module. Benefits. Description
Output relay module Benefits Integrated system. Dupline is the brand name for Carlo Gavazzi s 2-wire bus system. Cost reduction. The use of a bus system is a proven way to reduce installation costs - especially
More informationLC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationMinicontactorrelay,2NO/2NC,DCoperated
Minicontactorrelay,2NO/2NC,DCoperated Partno. DILER-22-G(24VDC) Articleno. 010042 CatalogNo. XTRM10A22TD Deliveryprogramme Product range DILER Mini-contactors Application Contactor relays Connection technique
More informationPROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES
Programmable DC Source Sink and Source Capability Conventional DC sources usually have the function of power supply (source) only without power absorption (sink) function. In addition to the source function,
More informationThe Art of Engineering
The Art of Engineering Functionality DPST Switch DPST Sensing Switch Transfer Switch Passive Splitter Ethernet Switch ASI 3G Switch or DA E/T Switch Optical Switch up to 006 MHz L-Band Broadband Ethernet
More informationData Sheet GU-LCT-RY-V1-10 GU-LCT-RY-V1-11
Data Sheet GU-LCT-RY-V1-10 Part No.: AA-10276-001 Optical Input / Output: Glass Fibre GU-LCT-RY-V1-11 Part No.: AA-10276-002 Optical Input / Output: Plastic (POF) Picture shows AA-10276-001 (Glass Fibre)
More informationSwitching Power Module
Assembled in U.S.A. 5005757 Rev. A GCU-HOSP 243C ID. COT. EQ. IEC PEV /EC Class 2 +.800.523.9466 + 44.(0)20.7680.448 HomeWorks DI Power odule Switching Power odule The Switching Power odule family is a
More information2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR
2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR Power supply It is based upon the latest switch mode power supply technology, offering size reduction (i.e. 19 rack, 3U power supply), good
More informationType: DILM25 10(24V50HZ) Article No.:
Type: DILM25 10(24V50HZ) Article No.: 277119 Ordering information Rated operational current AC 3 400 V I e A 25 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationPBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories
PBC series IEC-Type Contactors & Accessories 9-80 Amp AC-3, 25-125 Amp AC-1 AC Coils File E38802 (PBC) RoHS Ready Users should thoroughly review the technical data before selecting a product part number.
More informationMCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features
Microprocessor Controlled Constant Current Regulator Compliance with Standards FAA: ICAO: IEC: 61822 CENELEC: AC 150/5345-10 (current edition), L-828, L-829. Aerodrome Design Manual Part 5, para. 3.2 (current
More informationLC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil
Product data sheet Characteristics LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationOrdering details. Approval. Classification
Datasheet - SRB 301MC-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301MC Fit for signal evaluation
More informationType: DILM12 10(24VDC) Article No.:
Type: DILM12 10(24VDC) Article No.: 276845 Ordering information Rated operational current AC 3 400 V I e A 12 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationLC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil
Product data sheet Characteristics LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationStandard RS232 RS ma
1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision
More information9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218
9 Control Equipment Measurement- and Control Equipment Series, Explosion protection to CENELEC IEC Can be used in Zone 1 and Zone 2 Designed for panel mounting Enclosure material : Polyester resin : Aluminium,
More informationLVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:
HM 1808 LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement
More informationGamma instabus. Technical product information
Gamma instabus Technical product information Universal dimmer N 554D31, 4 x 300 VA / 1x 1000 VA, AC 230 V Universal dimmer N 554D31 Control of dimmable lamps, including LED without minimum load Output
More informationHenkel Installation Handbook LINEGUARD 2001
Henkel Installation Handbook LINEGUARD 2001 HENKEL ITALIA S.r.l. Microprocessor instruments Henkel Installation Handbook Lineguard 2001 Page 2 Summary 1. The Microprocessor Instruments... 4 1.1. Norms
More informationSimply clever! The digital DIN-rail time switches by Grässlin
Simply clever! The digital DIN-rail time switches by Grässlin talento pro Trends and developments on the market. Maximum energy efficiency at low efforts In a saturated fast-moving market, the trend towards
More informationLED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series
Driver LC 200W 1050mA UNV ADV IND ADVANCED series Product description Independent constant current LED Driver For dry, damp and wet locations Max. output power 200 W Up to 93.7 % efficiency For luminaires
More informationCAMTO LTD. Arc detecting system DC/AC
CAMTO LTD Arc detecting system DC/AC Arc detecting system DC/AC The system is based on experience with arc protection since 1962. The system units are built into boxes that all fit on a 35 mm DIN-rail.
More informationTechnical data. General specifications. Indicators/operating means
Model Number Single head system Features Sensor head bidirectional and rotatable Function indicators visible from all directions Quick mounting bracket Selectable sound lobe width Programmable Diagrams
More informationTechnical Specifications
This appendix contains these topics: Environmental Specifications, page 1 Specifications for the Catalyst 2960-X Switches, page 2 Specifications for the Catalyst 2960-XR Switches, page 5 Environmental
More informationSpecial Applications Modules
(IC697HSC700) datasheet Features 59 1 IC697HSC700 a45425 Single slot module Five selectable counter types 12 single-ended or differential inputs TTL, Non-TTL and Magnetic Pickup input thresholds Four positive
More informationMBUS 10 RS232 TO MBUS LEVEL CONVERTER
Media and protocol converters MBUS 10 RS232 TO MBUS LEVEL CONVERTER RS232 to MBus level conversion Maximum 10 MBus slaves Baud Rate: 300 to 19200 bps RS232 MBus opto isolation Over-current and short-circuit
More informationTechnical Specifications
This appendix contains these topics: Environmental Specifications, page 1 Specifications for the Catalyst 2960-X Switches, page 2 Specifications for the Catalyst 2960-XR Switches, page 6 Environmental
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationDATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.
Advantys STB Advantys STB Input Module DATA SHEET Description The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source. Features
More informationABB i-bus EIB Universal dimmer 6155 EB for Installation
73-1 - 5975 23459 ABB i-bus EIB Universal dimmer 6155 EB - 101-500 for Installation Operating instructions only for authorized, skilled electricians with EIB training Important instructions Attention It
More informationLC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationInstruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control
Series 3000 Model R-165A Audio/Video IF/RF Relay Panel Instruction Manual CATV Switching and Control 585-765-2254 fax 585-765-9330 100 Housel Ave. Lyndonville NY 14098 www.monroe-electronics.com Table
More informationLC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationMAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams
MAXTECH, Inc. Technology for Communications BRC-1000 Series C-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic
More information45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5
SPACEGUARD SERIES Description 1-12 metre sensing range 16 to 56 parallel scanning beams Active height of 0 mm to 2520 mm Detector length of 1928 mm to 2648 mm 3 different channel placement models Cable
More informationLC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil
Bảng thông số sản phẩm Đặc diểm LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationPreset Counters. X e. X d 6.92 X. 0. IP khz Batch. LCD Preset Counters 1, 2, 4 or 6 Presets. Multifunction. Fast and user-friendly
The Codix 923/924 can be used universally. As a preset pulse counter, tachometer or preset timer with up to 6 presets it is able to solve a very wide range of control and monitoring tasks in every application.
More informationMagnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A
72 Power Series SPDT 20 A; DPDT 15 A UL listed when used with proper Magnecraft sockets The 72 Plug-in Power relays offer clear or full-feature covers with multiple mounting options and accessories. Feature
More informationLC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil
Product data sheet Characteristics LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationProduct Manual. ABB i-bus EIB / KNX Switch/Dim Actuators SD/S. Intelligent Installation Systems ABB
Product Manual ABB i-bus EIB / KNX Switch/Dim Actuators SD/S Intelligent Installation Systems ABB This manual describes the function of the Switch/Dim Actuators SD/S x.16.1 with its application programs
More informationBulletin 190 IEC Modular Starter System
Bulletin 90 Table of Contents Selection Guide Description Page Bulletin 90....................................... Accessories....................................... 7 Specifications.....................................
More informationCSM Color sensors. Color sensors for the detection of a single color in restricted space conditions
CSM Color sensors Color sensors for the detection of a single color in restricted space conditions Due to its compact design, the CSM can be used in the most confined of spaces. The choice of color tolerance
More informationSTBART0200K standard analog input kit STB - 2 I - 15 bits + sign
Product data sheet Characteristics STBART0200K standard analog input kit STB - 2 I - 15 bits + sign Main Range of product Product or component type Kit composition Analogue input type Analogue input number
More informationInstallation Instructions
Installation Instructions Product Functional Details Overdrive ODMR0210 Dimmer + Controller Overdrive Dimmer Controller with MOSFET control provides the finest dimming for low light levels and strong lamp
More informationAbsolute Encoders Multiturn
The Sendix 5863 and 5883 multiturn encoders with SSI or BiSS-C interface and optical sensor technology can achieve a resolution of max. 29 bits. A through hollow shaft up to 4 mm and a blind hollow shaft
More informationType Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model
Low Signal Relay G6E Subminiature 7.87 H x.1 W x 16 L mm (0.31 H x 0.3 W x 0.63 L in). High sensitivity with pick-up coil power of 8 mw. Surge withstand meets FCC Part 68 rule and Telcordia 2.5 kv Specifications.
More informationI/A Series Hardware Fiber Optic LAN Converter
I/A Series Hardware PSS 21H-7F3 B4 The provides bidirectional conversion between coaxial and fiber optic media. The converter is compatible with existing I/A Series system hardware, utilizes industry standard
More informationPRINCIPLES AND APPLICATIONS
GENERATION & NETWORK Digital Automation Measuring and Control Devices AMS7000 PROCOM The optimum operation of an electrical network depends particularly on the reliability and the availability of the protection,
More informationDigital Input Modules for Compact FieldPoint
Digital Modules for Compact FieldPoint NI cfp-di-300, NI cfp-di-301, NI cfp-di-304, NI 8-,16-, or 32-channel inputs 24 VDC inputs 4 to 250 VDC inputs 15 to 250 VAC inputs (50/60 Hz AC) 3 to 250 VAC inputs
More informationLC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil
Product data sheet Characteristics LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationwith handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 25A power contactors silent CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Dimensions... 1 4. Positioning - Connection...
More informationHYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.
Linear / area dimming Constant current LED driver DALI Dimmable Product description Dimmable built-in constant current LED Driver Adjustable output current between 1,050 and 1,750mA via DIP switch Max.
More informationTechnical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.
Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE programmable switch outputs Selectable sound lobe width Synchronization options
More informationSingle output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.
RoHS Lead-Solder-Exemption Compliant New 3.3 V and 5 V Output Models Universal Input 85-264 VAC Industry-Standard Footprint: 7.0" x 4.3" x 1.97" (177.8 x 109.2 x 50.0 mm) Input Transient & ESD Compliance
More informationLinear flow control with actuator IFC
Linear flow control with actuator Product brochure GB 3 Edition 01.14 Linear relationship between adjustment angle and flow rate Large control ratio of 25:1 EC type-tested and certified Actuators IC 20
More informationUser Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.
EF User Guide UD51 Second encoder small option module for Unidrive Part Number: 0460-0084-05 Issue Number: 5 www.controltechniques.com Safety Information The option card and its associated drive are intended
More informationUNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load
More information